Programmable Controller

NEW KV-8000 Series

Identify the cause of problems. Ensure quick recovery.

The World’s First Built-In


Machine Operation Recorder Function
Fact: 20% of the day is spent stopped
due to problems

20% Planned downtime: 5% [Human Factor]

Problem-related
stoppage Incorrect parameter settings

Improper workpiece loading

Equipment
operating
status*

Operating time:
75%
* Investigation performed
by KEYENCE

[Mechanical Factor]

Motor overload and mechanical wear

False sensor detection

Know the cause of problems


with the Machine Operation
Recorder function

[Program Factor]

Signal timing error

Incorrect interlock

2
Quick recovery by knowing the cause of problems
and performing fundamental countermeasures

Recording
Recording of all data
Records all devices, cameras, and events.
All equipment data is recorded automatically.

Playback
Replays
View linked playback of various data
sources recorded from the moment a
problem occurred.

Analysis
Relation mapping
Automatically analyse ladder programs and
view tree-diagrams of related devices.

NEW
Programmable Controller
KV-8000 Series

3
Significantly reduce downtime with
on-site machine operation recorder PLCs

p to rec overy
e from e quipment sto
f tim
Overview o
ls use
nal mode g the ca
Conventio ❚ Investig atin
uch as
ause s
c
rise the or prog
ram
g the situation •C ate g o
c h in e
tandin the ma the pro
blem
❚ Unders quipmen
t status due to o d u c e
ation of
e to repr
• Wait
• Confirm ith operato
rs
ltation w
• Consu

e d to
the caus as relate
g re No nce
eries estigatin ction of a re o c
c ur r e
000 S ❚ Inv extra ycle
KV-8 ion oma
tic
orma
lc
he situat • Aut m of n
g t roble rison
erst andin g of the p m compa
❚ Und re c ordin vefor
toma
tic • Wa
u ta
• A
m e nt da ction of
p
equi re prod
u
skto p
• De
tion
situa

Reasons to reduce downtime

Quicker understanding of the situation


Collecting accurate information is essential for knowing
the status of equipment. The KV-8000 automatically
records data both before and after stoppage, allowing
users to quickly and accurately track statuses.

Equipment and workpiece


appearance

Program behaviour

Automatic Operator actions


recording

4
ag ain
o f pro blem te t he cause
urrence nd inve
stig a
❚ Reocc ation a
situ
eter mine the
D

r fun ction
corde
ration Re
e Ope
e M achin
th
Using

Fast investigation of causes Prevent reoccurrences


Isolating the cause of a problem is necessary for solving If the cause of a problem is not understood and proper
the problem quickly. The KV-8000 features a variety of countermeasures are not implemented, reoccurrence will
functions for analysing mechanical, human, or program be likely. Identifying the underlying cause of a problem with
factors, which make up the majority of problems— the KV-8000’s Machine Operation Recorder function can
ensuring quick troubleshooting investigation. help prevent problems from happening again.

Equipment stoppage Conventional models

Equipment Reoccurrence
restart of problem
Various problem
analysis functions
available KV-8000
Investigating
the cause No
+
Camera-based initial Equipment reoccurrence
checking when a restart
problem occurs
Increased operation rate
by preventing reoccurrence

5
Lineup

CPU

CPU unit KV-8000 CPU unit KV-8000

Basic performance

LD instruction execution speed 0.96 ns

Program capacity 1500 k steps max.

Functions

Machine Operation FTP client/


Recorder function Server

Logging/trace

Communication port

EtherNet/IPTM USB

Camera

Compact standard camera Compact standard camera KV-CA1H


KV-CA1H
Basic performance
Resolution 640 (H) × 480 (V)
Frame rate 10/30/120 fps
Camera input unit Horizontal viewing angle: Approx. 60°/
Viewing angle
KV-CA02 Vertical viewing angle: Approx. 47°

Wide field and high-


Wide field and high-resolution camera KV-CA1W
resolution camera
KV-CA1W Basic performance

Resolution 1280 (H) × 960 (V)


Frame rate 10/30 fps
Horizontal viewing angle: Approx. 180°/
Viewing angle
Vertical viewing angle: Approx. 150°

Camera input unit KV-CA02

Basic performance
Maximum number of connected units 4
Number of ports 2
Cable length 5/10/20 m

KV STUDIO Ver. 10 KV REPLAY VIEWER

Supported modes Supported modes

• Editor • Replay
• Monitor *Downloadable for free
• Online Edit from KEYENCE website
• Simulator
• Simulator Edit
• Replay NEW

6
I/O

Input 16-point 32-point Connector 64-point Connector


Screw Terminal Block
Input Unit Input Unit Input Unit
KV-B16XC KV-C32XC KV-C64XC

Output Screw Terminal Block 16-point Screw Terminal Block 32-point Connector 64-point Connector

16-point Relay Transistor (sink) Transistor (sink) Transistor (sink)


Output Unit Output Unit with Output Unit with Output Unit with
KV-B16RC Overcurrent Protection Overcurrent Protection Overcurrent Protection
8-point Relay Output KV-B16TD KV-C32TD KV-C64TD
(Independent Common Transistor (source) Transistor (source) Transistor (source)
Point) Unit Output Unit Output Unit Output Unit
KV-B8RC KV-B16TCP KV-C32TCP KV-C64TCP

Input/ 64-point Connector 16-point Screw Terminal Block 32-point Connector


Output
Hybrid
32-point Input + 32-point 8-point Input + 16-point Input +
Transistor (sink) Output 8-point Transistor 16-point Transistor
High-speed I/O Unit (sink) Output Unit (sink) Output Unit
KV-SIR32XT KV-B8XTD KV-C16XTD

Analogue

4 ch 4 ch 2 ch Analogue 4 ch 4 ch Temperature/
High-speed High-speed Input + Temperature Analogue
Analogue Analogue 2 ch Analogue Control Unit Multi-input Unit
Input Unit Output Unit Output Unit KV-TF40 KV-TP40
KV-SAD04 KV-SDA04 KV-AM40V

Positioning/Motion High-speed counter

4-axis 16-axis 4-axis Pulse Train 2 ch


MECHATROLINK-III MECHATROLINK-III High-speed High-speed
Positioning/Motion Unit Positioning/Motion Unit Positioning Unit Counter Unit
KV-XH04ML KV-XH16ML KV-SH04PL KV-SSC02

Communication Power supply

Ethernet Serial Serial AC Power Supply Unit


Unit Communication Unit Communication Unit with Error Output
KV-XLE02 KV-XL202 KV-XL402 KV-PU1

Network Bus Connection

CC-Link DeviceNetTM KL Master Bus Connection


Master/Local Unit Unit Unit Unit
KV-CL20 KV-DN20 KL-N20V KV-7000C

7
Recording Recording of various data
Records all devices, cameras, and events.
All equipment data required for solving problems is
recorded in chronological order.

Device

Record all device changes every scan WORLD FIRST

All device changes and ladder programs are recorded every scan time.
Recording is performed just as if the ladder programs were being captured in real time.

Record all signal behaviours

Camera

Record all mechanical, workpiece, and human movements WORLD FIRST

The statuses of all equipment, workpieces, and mechanisms are recorded both before and after the problem occurred.
Because the device is connected to the PLC, the ladder program status and the image captured by the camera are
recorded in sync.

Compact standard
camera
KV-CA1H
Application: Workpiece and
mechanism monitoring

Wide field and high-


resolution camera
KV-CA1W
Application: Overall
equipment monitoring

8
Event

Record external input history WORLD FIRST

In addition to PLC error and alarm information, touch panel operation history and all inputs from upstream/downstream PLCs
and from the host PC are recorded. This ensures all history related to problems caused by hard-to-notice incorrect operations
or external factors is retained.

Operator actions

Upstream/downstream PLCs
Host system/PC

Recording of equipment changes

One-step configuration of settings for solving various problems

WORLD FIRST

One-step trigger setting Ensure reliable recording of stoppages without alarms

Recording a problem is as easy as setting a trigger. Configuring a fixed recording time based on equipment cycle
Whenever a trigger is input, all preceding and following start is possible for any device that has stopped without an
device changes are automatically recorded. This alarm being generated.
eliminates the need to select and register a target device.

❚ Storage period
Pre-/post-trigger recording ❚ Non-storage time
Collection
period

Set the trigger device and the


conditions. File save trigger Recording both
Cycle recording before and
after problems
Collection
period

Collection start relay File save trigger Equipment


Only this setting is required. Equipment cycle start relay cycle recording

9
Playback Linked playback of all recorded data

Records all devices, cameras, and events.


Recorded data can be played back in sync.

Device

Tracked monitoring of the time axis


All recorded ladder programs can be played back at will.
With all device changes being recorded, various monitoring functions can be used to check device statuses.

Check device statuses at any time, starting with when the Device changes can be displayed as
Register up to
problem occurred. waveforms for at-a-glance recognition
24 words at
of timing deviations. 64 bits

Camera

Linked video playback and ladder monitoring


Video captured both before and after a problem can be played back in sync with device changes.
Having an accurate understanding of the situation makes understanding the cause of the problem much easier.

Video captured by the camera can also be separated as Video captured by the camera can be
dialogues and resized as desired. Users can also change displayed and synchronised by time Time-based
the frame rate and playback speed, making it possible to with the waveform data. This makes it synchronisation of
quickly check any operation. easy to see changes in status camera video and
device information
resulting from changes in the device.

10
Event

Time-based external input and operation history checking


The event/error history can be used to check changes in device values not resulting from programs.
Easily identify incorrect operations from the touch panel or PC as well as incorrect settings.

Link

Checking device value changes is possible on a PC


This makes it possible to see changes in chronological order. using the same screen data as the touch panel.

Device value changes (touch panel/PC/PLC)

Communication SD memory card


Program rewriting
status insertion/removal

Various monitoring functions available

Unit monitor Registration monitor / Sensor I/O monitor


Batch monitor

Recording the buffer memory of Monitor any specific device or batch Monitor the current values and setting
positioning units and other units monitor any specific device types. values for each KEYENCE sensor
enables close monitoring of unit connected to the KV Sensor Network.
statuses.

11
Analysis Impressive cause investigation time

Equipped with a mechanism that minimises time spent


investigating the cause of problems.

Conventional problem analysis

Analysis using incredibly large ladder programs


The ladder programs of PLCs that control equipment are complexly related to a wide variety of other programs, including motor
control, communication control, and error processing.
Because of this, finding the cause of a problem can take a lot of effort.

12
Relation mapping

Automatic tree diagramming of locations related to the problem


WORLD FIRST

Search/extract not only device and configuration changes related to the problem but also device rewrites from the touch panel,
and create a tree diagram automatically.
Causes can be investigated early just by following the block.

Relation mapping block information

Device blocks Setting blocks


Displays the devices used in the Displays the unit number and name
ladder block diagram. Switch freely of the unit setting being used by the
between the device comment specified device.
display and the device display.
Settings List
• PLC link • PROTOCOL STUDIO
• Industrial Ethernet
Ladder blocks • Simple PLC link
• FL refresh settings
Displays the line number and • Serial PLC link
module name where the specified • Default device value settings
device is being used. • Inter-unit synchronisation refresh

Flow blocks Device value change blocks


Displays the target unit number for Displays when the device values for
specified devices used in unit the specified device are changed
programs (flows). from the touch panel or access
window.
*Only in monitor/online edit/replay mode.

13
Analysis Efficient cause analysis
Utilise a variety of analysis tools to investigate causes in various ways.

Relation mapping

Automatic ladder extraction WORLD FIRST

Automatically extract related ladder programs by selecting a block within the relation mapping.
This eliminates the need to search through large ladder programs, making it easier to find causes quickly.

Click + to expand related blocks

Automatic extraction and


collation of related ladder
programs

Reduce debugging times One-click startup


Relation mapping is also a useful tool in editor mode. See In replay mode, one-click launching is possible from the
at a glance the scope to which the device being changed icon in the operation bar. The interface ensures ease of use
will be affected during debugging to help prevent when investigating causes.
programming errors.

Impact of device change


(Blocks located on the right)

14
Waveform comparison

Visual comparison of differences with normal operation status


When determining the cause of a problem is difficult, such as with sudden stops, waveform comparison
makes it easy to visually identify causes by superimposing a normal waveform.

Simply load a file to compare the waveforms on the same screen.

CSV file and waveform comparison Easy-to-view waveform comparison


The waveform data to use for comparison can be imported Overlapping waveforms for comparison makes it easy to
from a CSV file in addition to an RTCM format file and the determine differences in shape and to see deviations in
operation record. This function can be used in a wide timing through side-by-side comparison. The time axis of a
variety of applications including comparing waveforms of waveform can be adjusted as desired for comparison.
data logged using KV Series devices.

Side-by-side waveform
Operation comparison
recording
File import

RTCM

CSV Overlapping waveform


comparison

15
For manufacturing and maintenance workers

Quick identification of problems


From understanding the situation when a problem occurs to isolating the cause and taking the necessary
countermeasures, the time it takes to resolve problems can be greatly reduced.

Problem 01

With no record for reference, it’s not possible to know what’s going on.

It might not Problem details


happen even if ❚ There’s clearly a problem, but the problem doesn’t occur during on-site
Did it just I go... inspection.
occur? ❚ Even when checking the device after the problem occurs, the device will
have already been restarted, and no record of what happened will be
Should we available.
just wait
Maintenance ❚ Checking with the on-site operator might not provide a detailed account
worker A and see?
of the situation.

KV-8000 Solution

Automatic recording makes understanding the situation easy.

Reliable record for reproducing and checking what happened


The KV-8000 records data whenever a problem occurs, allowing users to analyse the occurrence by reviewing the data
obtained. This ensures accurate understanding of the situation even for problems that do not occur frequently.

1 Transferring of operation record to PC 2 Reproducing the problem on a PC

Equipment Operation
information from recording
both before and
after the problem

Automatic recording of various problems


Recording data both before and after an error or alarm signal, and recording according to the cycle start whenever the
equipment cycle ends, makes it possible to reproduce the exact moment an error stop occurred. This helps in discovering a
solution to the problem.

Comparing the situation both before and after the problem Equipment cycle comparison
Playing back the Subtraction
recorded data comparison is used
makes it possible to to compare
compare how the equipment cycle
situation changed. waveforms.

16
Problem 02

Understanding programs created by others is difficult.

Problem details ❚ Every person or vendor has a unique way of writing programs and program rules.
❚ Tracking down related devices from a large number of programs can be difficult.

KV-8000 Solution

Analysing the cause is possible regardless of who created the program.

Extraction of only Overview of error


cause analysis
related devices
Equipment
operation stop
The devices related to an error can
be extracted and automatically
Unacceptable
displayed in a tree diagram based measurement results
on their relationships for easy
visualisation. This makes it possible Measurement
to track down relevant devices even errors

without understanding each


individual program.

Problem 03

Determining the cause requires taking time for analysis.

Problem details ❚C
 hecking all of the possible problem points is time-consuming.
❚ Identifying the cause of the problem is difficult and depends on the skill of the
inspector.

KV-8000 Solution

Reduce the time required for determining the cause.

Various functions for quickly Check for visible changes Operation history Software-based device
1 using the camera 2 event checking 3 change analysis
narrowing down problems to
Problems isolated Problems isolated Problems isolated
mechanical, human, or to machine to user to program
program factors Mechanical Human Program Mechanical Human Program Mechanical Human Program

Using the KV-8000 allows users to go back


in time to the moment a problem occurs,
review the situation using the camera,
check the operation history, and analyse
the software, ensuring efficient cause
analysis from a single operation record.

17
For equipment production workers

Fast debugging and startup


Efficiently respond to problems that arise in various situations after design, debugging, startup, or installation.

Problem 04

Obtaining accurate information is impossible without going to the site.

Problem details
Did someone
❚ The conditions for the problem are not clear even through consultation
Did a mess with it?
with the operator.
machine
❚ The equipment is far away, meaning a business trip is required to
break?
analyse the situation accurately.
Is it a ❚ Being properly prepared before getting to the site is important, but with
software
Electrical no way of knowing the situation or any idea of the cause, deciding what
designer B
bug?
preparations are required is impossible.

KV-8000 Solution

The ability to remotely reproduce the situation when the problem occurred
improves response efficiency.
Accurate understanding of the situation without leaving the office
Delivery destinations for equipment are often remote, including overseas, making it difficult to get an accurate grasp of the
situation by phone or email information when a problem occurs. The KV-8000 automatically records information from ladder
programs, cameras, and events onto an SD card, enabling a thorough understanding of the device status just from the
received data.

Remote reproduction of the


1 Automatic recording 2 Operation record forwarding 3
problem and situation
Automatic
recording of
ladders,
camera videos,
and event
information
Factory Office

Limit the number of required trips, and ensure proper preparedness


The ability to reproduce the situation when the problem occurred without needing to be on site makes it possible to determine
whether the situation can be rectified without the need for travel. If travelling to the site is necessary, only the necessary
preparations can be made before departing, reducing overall labour hours.

Conventional models KV-8000

Problem Problem

Reception of operation record


Call from end user
from end user

Incomplete understanding of Remote situation and


the situation or cause cause analysis

Determine the situation by linking the operation


Determination of the need for
On-site analysis required record and touch panel screen data without ever
on-site analysis
needing to be on-site.

18
Problem 05

Debugging and startup take time.

Will the operation Problem details


An error was change if corrections
generated, but are made? ❚ Operation is normal when debugging, but problems occur
the situation can’t after startup.
be reproduced.
❚ Modifying a program could affect other parts, resulting in
Could it be even more problems and taking even more time.
Production the timing?
engineer C

KV-8000 Solution

Visualisation makes it possible to quickly investigate causes.

Comparison with a master waveform for fast identification of causes


Device information is recorded automatically, allowing for reduced cause analysis time by comparing a normal operation
record during debugging and the operation record when a problem occurs.

1 Advance recording of normal equipment information 2 View differences using waveforms

Waveform with
Operation problem
recording occurrence

Normal
waveform

Reduce correction errors during debugging


Debugging involves many fine modifications to programs, making it difficult to determine the ripple effect of every correction.
Reviewing the scope of impact using the tree diagram and recording problems that arise allow users to quickly find the cause
of any errors.

Check the impact of changes on the tree diagram One-touch problem status recording

Trigger input

Recording

Not saved Saved Not saved

Visualise how much an


impact can be The KV-8000 constantly buffers equipment information,
expected. so data can be recorded as soon as the save trigger is input.

19
For management workers

Increase operation rate


Reducing equipment downtime is a key aspect to improving the rate of operations at a manufacturing site. Nevertheless,
eliminating equipment stoppage all together is very difficult. This means predictive maintenance for preventing problems before
they occur, and appropriate responses whenever a problem does occur (follow-up maintenance), have become important.

Planned
downtime
❚ Overview of equipment operating status
5%
Operating time Problem-related stoppage
75% 20%

Main causes of equipment stoppage

❚ Wear of mechanical mechanisms


❚F
 alse detection due to sensor
Mechanical Factor [Typical Problems]
deterioration
❚V
 ariations in workpiece shape

❚ Incorrect workpiece loading


Human Factor [Typical Problems] ❚ Incorrect parameter settings
❚U
 nexpected operation

❚ Signal timing error


Program Factor [Typical Problems] ❚ Incorrect interlock
❚C
 alculation error

Reducing equipment stoppage time


At manufacturing sites, problems generally fall under two
Advanced Follow-up
categories: situations that can be prevented (advance handling) Monitor signs to Solve problems that
or events that cannot be prevented (follow-up handling). For prevent problems occur as quickly as
beforehand possible
events requiring follow-up handling, resolving the issue as
quickly as possible is essential.

20
Advanced Follow-up

Predictive maintenance Machine Operation Recorder function


solutions for reducing problem response time

With the fastest processing speed in its class, The Machine Operation Recorder function can record
the KV-8000 Series enables predictive maintenance by and play back equipment information from both before
collecting large amounts of data for use in advanced and after a problem occurs, making it easy for all users
analysis. to resolve the situation.

❚ Solution examples ❚ Equipment information recording and linked playback


Multivariate analysis (MT method)

• Analysis of abnormal
situations
• Visualisations of items with
greater influence

Frequency (FFT) analysis Camera


Ladder program
• Bearing wear detection
• Cutting tool deterioration
analysis
Waveform

❚ Reduced work for improved efficiency and flexibility


Waveform monitoring (guard band)

• Temperature profile
monitoring
• Time-based monitoring of
press pressure Mechanism for simplified analysis even of programs
written by third parties

Application for visualising


operation rate
The KV-8000 enables visualisation of the
equipment’s overall efficiency, operating
status, and equipment stoppage factors
from an on-site touch panel. This allows Production Record OEE / Loss analysis Pareto alarm chart
users to check changes in the operation
rate quickly and easily.

21
Various functions to assist in problem-solving

Recording

Support for various applications


Customisable recording settings
with up to four configurations
Up to four IDs can be used with the Machine Operation Recorder With the ability to change the sampling cycle timing as desired,
function. This enables not only data recording before and after a to narrow down the number of recording devices, to extend the
problem occurs but also various applications, such as cycle recording time, and to change recording settings as desired, the
monitoring or trend monitoring with longer sampling cycles. KV-8000 can be used in a wide variety of applications.

Settings can be configured as needed for each application.

Freely split and save


Highly reliable industrial SD card
operation records
KEYENCE offers high-reliability SLC-type SD cards. These The operation record can be saved not only as separate files
cards are ideal for use with the Machine Operation Recorder with a specified file sized but also for any specific period of time.
function, as the equipment information recorded when a problem Data can be sent to equipment designers as an e-mail
occurs, which tends to be excessive and indispensable. attachment directly after a problem occurs.

What is SLC?

SLC is the abbreviation for


single-level cell, where 1 bit of
data is stored in a single cell.
This ensures data is saved at a
KV-M16G
high quality.

KV-M4G

Playback

KV REPLAY VIEWER Replay linking with


software for replay mode touch panel screens
KV REPLAY VIEWER is special software that enables playback With linking in replay mode, device changes and bit ON/OFF
and analysis of the operation record even without using statuses can be viewed as touch panel screen data. The
KV STUDIO. With no risk of programs being rewritten, the availability of a screen for confirming startup operation makes it
software is ideal for maintenance work. easier to understand the situation faster.

❚ Supported modes Replay VT Viewer

Replay mode
Editor Monitor Online Edit

Simulator
Simulator Replay
Edit

22
Analysis

Device change-point searching FTP uploading of operation record

Search for device changes in chronological order. In addition, Using preset function blocks allows the operation record to be
because the replay position can be changed from the search uploaded to a PC via FTP. This enables immediate analysis
results for the change point, factor analysis can be performed whenever a problem occurs without ever having to be on-site.
with greater efficiency.

❚ Bit device ❚ Word device ❚ Parameter setting ❚ FTP transmission (by folder)

Camera

Strong global shutter for capturing


IP65F rating
moving objects
The adoption of a global shutter enables exposure and The IP65F rating signifies a waterproof and oilproof
capturing of all pixels at the same time. This ensures the high- construction. This device can be used with peace of mind even
speed movement of mechanical mechanisms can be captured in the harshest production environments.
with no blurring, eliminating the possibility of missing
momentary changes.

Support for hot-swapping


during operation
Cameras can be removed freely from the camera input unit even
while power is being supplied. In addition, because the unit
remains powered, any camera installed later can also be used
immediately just by connecting it to the unit.

Video adjustment from


File saving of camera data
the touch panel
Video adjustments such as quality and exposure can be Convert recorded camera data into video files or image files.
performed not only from KV STUDIO but also from VT5 Series These files can be used when contacting remote users and for
devices. A dedicated screen ready for use without drafting reporting problems.
ensures adjustments can be made efficiently at startup.

[Video adjustment settings]


❚ Exposure
❚ White balance
avi
❚ Image quality
❚ Contrast
❚ Sharpness
Camera
❚ Screen orientation
data Save any information
(180° rotation) at any size jpg

23
High-performance PLC for improved equipment performance
KEYENCE’s high-performance PLC system is ideal for a variety of equipment control situations.

High-speed and high-accuracy control that is the best in the industry

Positioning/motion unit with AC servo system with


MECHATROLINK-III compatibility MECHATROLINK-III support

KV-XH16ML/ SV2-xxxL2
KV-XH04ML

FASTEST IN CLASS

❚ Motion control period of 125 µs for five axes ❚ High-speed response ❚ High accuracy
With a motion control–dedicated Dual Core CPU and Start motors at high speed through With the fastest control period among
MECHATROLINK-III compatibility, KV-X MOTION autonomous decentralised control with the similar products, KV-X MOTION boasts
ensures the fastest control period in its class. unit, and with high-speed bus powerful control required for position
communication with the CPU. instruction accuracy.

Internal SoC Comparison of time between CPU unit input


Position instruction accuracy comparison
Dual Core CPU and servo motor movement
Conventional models Conventional Control
Position instruction

Parallel
1 GHz Core Processing
1 GHz Core (1) (2) (4) 6.3 models period
(3) 3 ms
• Axis control calculation • Axis control calculation 1 ms 1 ms 1 ms ms
processing processing (5) 0.3 ms
• Parameter management • Unit program processing KV-XH16ML 1 ms Time
(1) 1.5 4× faster than 8× faster than
1 ms ms conventional models conventional
KV-XH16ML models
Position instruction

0.5 ms for (2) to (5) [0.125 ms per step]


CPU inner bus slave Control
MECHATROLINK-III master (1) Scan time (2) Control period period
• High-speed communication
• High-speed communication (3) Unit internal processing
with the CPU unit (4) Communication time
with the servo amplifier
• Buffer memory access (5) Servo internal processing 0.125 ms Time

24
Connectable to various PLCs and factory automation equipment from all over the world

Ethernet unit Serial communication unit


KV-XLE02 KV-XL202 /
KV-XL402

RS-232C
RS-422A/RS-485

❚ Program-less communication with ❚ Ladder-less communication with everything from


over 100 PLC models INDUSTRY FIRST measurement systems to robots
KV-X COM is compatible with PLC link functionality for use with PLCs Communicate with third-party devices without the need for bothersome
from various vendors, and with four major global industrial Ethernet communication programs, including for command definition and for
technologies. Easily link data and utilise visualisations with new and old processing when sending/receiving commands. This drastically reduces
equipment alike. the amount of time needed for communication setting work.

❚ Devices that support presets with


PLC link Ethernet communication
function Category Vendor/protocol name
PLCs from
❚ Ethernet Sensor/displacement sensor/
various measurement system
❚ Serial vendors Image processing system
KEYENCE
2D code/barcode reader
Laser marker/inkjet printer
Recorder
RKC Instrument
Industrial Temperature adjuster Yokogawa
Ethernet PLCs from Azbil
Inverter Mitsubishi
❚ EtherNet/IPTM various YASKAWA
❚ EtherCAT® vendors FANUC
Industrial robot EPSON
❚ CC-Link IE Field YAMAHA
DENSO
❚ PROFINET
General-purpose Modbus/TCP
protocol SLMP

Continued dedication to PLC performance for improved productivity

❚ PLC-specific SoC for higher performance ❚ Bus system that enables both high-speed
FASTEST IN CLASS performance and synchronisation
By speeding up the core clock as well as simultaneous execution of The CPU inner bus ensures large-capacity bus communication and
multiple instructions, basic instruction execution speeds of 0.96 ns—the responsiveness such as unit interrupt, enabling high-speed and high-
fastest among similar products—are possible. accuracy control.

Highly accurate synchronisation between units


High-speed performance

Ladder
execution
engine

Ultra-
Dedicated
high-speed
control
CPU inner
CPU
bus
Responsiveness Stability

PLC-specific SoC Ultra-high-speed CPU inner bus

EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. 25
System configuration diagram

❚ Unit configuration
KV-5000/3000 Series
CPU unit KV-8000/7000 Series expansion unit Bus-connected unit expansion unit

KV-8000 KV-CA02 KV-7000C

Industrial SD card Compact standard Wide field and


Camera cable
camera high-resolution camera
KV-M16G (16 GB) KV-C5 (5 m)
KV-M4G (4 GB) KV-CA1H KV-CA1W KV-C10 (10 m)
KV-C20 (20 m)

❚ Related products

CPU unit Camera


Calendar clock Mounting adapter Adjustable bracket
retention battery OP-88386 OP-88387
KV-B1

Adjust the orientation


AC power supply unit Used for mounting vertically or horizontally
on a stand. as desired.
with error output
(Stand must be (Separately prepare a
KV-PU1 separately prepared.) support pole with a
diameter of 12 mm.)

❚ Camera field of view

Compact standard camera Wide field and high-resolution camera


KV-CA1H KV-CA1W

Horizontal field of view Vertical field of view Horizontal field of view Vertical field of view

232 mm Approx.
180°

200 mm
Approx. 150°
174 mm

200 mm

26
KV-8000 Specifications

❚ General specifications ❚ Performance specifications


Item Specifications Model KV-8000
System configuration using System configuration using Calculation control method Program storage method
System configuration an expansion unit for an only expansion unit for I/O control method Refresh method
KV-5000/3000 Series KV-8000/7000 Series Programming language Expanded ladder, KV Script, mnemonic
24 VDC 24 VDC Basic instruction 80 classes, 181 instructions
Power voltage
(±10%) (-15% +20%) Application instruction 50 classes, 67 instructions
Operating ambient 0 to +50°C*1 *2 0 to +55°C*1 *2 Number of
Calculation instructions 125 classes, 318 instructions
temperature (no freezing) (no freezing) commands
Expansion instructions 77 classes, 132 instructions
10 to 95% RH*1 5 to 95% RH*1 Total 332 classes, 698 instructions
Operating ambient humidity
(no condensation) (no condensation) Basic instruction Min. 0.96 ns
Ambient storage temperature -20 to +70°C*1 -25 to +75°C*1 Instruction Application instruction Min. 5.75 ns
execution
10 to 95% RH*1 5 to 95% RH*1 Double precision
Ambient storage humidity speed Min. 58 ns
(no condensation) (no condensation) floating-point instruction
Operating environment No dust or corrosive gas CPU memory capacity 64 MB
Operating altitude 2000 m or less Program capacity Approx. 1500 k steps
Pollution degree 2 16 units (KV-8000/7000 Series expansion unit only),
Overvoltage category I (II when using KV-PU1) Maximum number of units to be 48 units (KV-8000/7000 Series expansion unit,
installed KV-5000/3000 Series expansion unit
1500 Vp-p or more; (when extension unit (KV-EB1) is used))
Noise immunity pulse duration: 1 μs, 50 ns (based on noise simulator);
IEC standard-compliant (IEC61000-4-2/3/4/6) Maximum 3072 points for expansion
Maximum number of I/O points
(KV-EB1S/KV-EB1R: 2 units used, 64-point unit used)
1500 VAC for one minute
Withstand voltage (between the power terminals and the I/O terminals, Input relay
and between the external terminals and the case) Output relay R Total 32000 points 1 bit

Bit device
50 MΩ or more Internal auxiliary relay
(between the power terminals and the I/O terminals Link relay B 32768 points 1 bit
Insulation resistance
and between the external terminals and the case, Internal auxiliary relay MR 64000 points 1 bit
with 500 VDC megohmmeter) Latch relay LR 16000 points 1 bit
Intermittent vibration Scan times Control relay CR 1280 points 1 bit
Frequency Acceleration Half amplitude Timer T 4000 points 32 bits
Compliant
5 to 9 Hz – 3.5 mm 10 times in Counter C 4000 points 32 bits
with Data memory DM 65535 points 16 bits
9 to 150 Hz 9.8 m/s2 – each of X, Y,
Vibration resistance JIS B 3502
Word device

Continuous vibration and Z Expansion data memory EM 65535 points 16 bits


and Current bank FM
Frequency Acceleration Half amplitude directions File
IEC61131-2 524288 points 16 bits
register Dial mode ZF
5 to 9 Hz – 1.75 mm (for 100 min.)
Link register W 32768 points 16 bits
9 to 150 Hz 4.9 m/s 2

Temporary memory TM 512 points 16 bits
Acceleration: 150 m/s2, Application time: 11 ms, Index register Z 12 points 32 bits
Shock resistance
2 times in each of the X, Y, and Z directions
Control memory CM 7600 points 16 bits
Internal current consumption*3 400 mA or less
Number of Device comment Approx. 224000
KV-8000: Approx. 340 g,
Weight comments/
KV-B1 (battery): Approx. 10 g
labels stored in
main unit Label Approx. 285000
*1 Guaranteed range in which the system can be used.
*2 Specified according to the temperature in the control panel on the lower side of the unit. Program memory Flash ROM can be written 10000 times
*3 The maximum current consumption is 3.2 A when using the expansion unit. Device Nonvolatile RAM
Power off
hold function Backup capacitor lasts approx. 15 days (at 25°C)
Calendar clock
(Approx. 5 years with KV-B1 (battery) (at 25°C))
Self-diagnosis function CPU error, RAM error, and other problems
❚ Functional socket
No. of sockets
Model Port number
TCP UDP
PC application*1 16 0 8500 (set within the range of 1 to 65535)
Upper link communication*2*3 Total 1 8501 (set within the range of 1 to 65535)
MC protocol communication*2*3 15 1 5000 (set within the range of 1 to 65535)*4
VT connection 0 1 8502 (set within the range of 1 to 65535)
FTP server 4 – 20, 21
Automatic clock data adjustment – 1 123
E-mail transmission (SMTP, POP3) 2 – 25, 110
DNS – 1 53
FTP client 2 – 20, 21 (set within the range of 1 to 65535)
EtherNet/IPTM cyclic communication function Total 1 2222
EtherNet/IPTM message communication function 320 1 44818
KV socket communication Total 16 Arbitrary value (set within the range of 1 to 65535)
*1 Camera monitoring via KV STUDIO, KV COM+, or VT5 *2 TCP socket and UDP socket can be used simultaneously.
*3 Up to 15 TCP sockets can be used. *4 Port numbers can be set to TCP socket and UDP socket individually.

❚ EtherNet/IPTM communication specifications


Item Specifications
Supported transmission rates 100BASE-TX
Number of connections 256*1
0.5 to 10000 ms (0.5 ms unit); Can be set by connection.
RPI (communication cycle)
(Refresh line data at a set frequency regardless of the number of nodes)
Output to adapter Cyclic
Transmission trigger
Cyclic Input from adapter Cyclic/Change Of State*2
communicationAllowable band for (at 504 bytes) 10000 (pps)*3
CIP cyclic communication (at 1444 bytes) 5000 (pps)*3
service
Maximum number of refresh words 16 k words
Maximum data size for 1 connection*4 504 bytes or 1444 bytes
Multicast filtering function*5 Provided (IGMP client function)
Class 3 (connection type) Server Number of connections: 256*6
Message
Client Number of simultaneous actions: 32
communication UCMM
(non-connection type) Server Number of simultaneous actions: 96
EtherNet/IPTM conformance test Compliant with CT15

*1 In total, the number of connections used for the message communication function in Class 3 (connection type) should be a maximum of 256. *2 Can communicate with devices that output data using the
Change Of State (Send data when any change occurs) method. *3 Abbreviation of “packet per second”, indicating the number of sent/received packets processed per second. *4 Data synchronism in
connections is guaranteed. Also, when using 505 bytes or more, the device used must support Large Forward Open (an optional CIP specification). *5 The included IGMP client function allows the
KV-8000 to filter out unnecessary multicast packets by using an Ethernet switch that supports IGMP snooping. *6 In total, the number of connections used for the cyclic communication function should be a
maximum of 256. The KV-8000 supports Class 3 (connection type) tag specifications.

27
Specifications

❚ General specifications - KV-CA02 - ❚ Performance specifications - KV-CA02 -


Item Specifications Model KV-CA02
System configuration using System configuration using Connectable CPU unit KV-8000
System configuration an expansion unit for an only expansion unit for Maximum number of
KV-5000/3000 Series KV-8000/7000 Series 4
connected units
24 VDC 24 VDC Number of ports 2
Power voltage
(±10%) *3 (-15% +20%) *3
KV-CA1H (Compact standard camera)
Operating ambient 0 to +50°C 0 to +55°C Supported camera models
KV-CA1W (Wide field and high-resolution camera)
temperature (no freezing)*1 *2 (no freezing)*1 *2
Cable length 5/10/20 m*1
10 to 95% RH 5 to 95% RH
Operating ambient humidity Recording time Approx. 3 minutes*2
(no condensation)*1 (no condensation)*1
Ambient storage temperature -20 to +70°C*1 -25 to +75°C*1 Internal current consumption 260 mA or less*3
Weight Approx. 190 g
10 to 95% RH 5 to 95% RH
Ambient storage humidity
(no condensation)*1 (no condensation)*1 *1 Lengths of the KV-C5/C10/C20 camera cables.
Operating environment No dust or corrosive gas *2 Record time for one KV-CA1H with the following configuration of settings (initial value).
Operating altitude 2000 m or less The actual recording time varies depending on the number of devices, the frame rate, and the
image quality settings. Frame rate: 30 fps / Quality: 3
Pollution degree 2 In addition, the recorded video is cleared when the power is turned off.
1500 Vp-p or more; *3 Internal current consumption for the KV-CA02 only. Connecting a camera adds the internal
Noise immunity pulse duration: 1 μs, 50 ns (based on noise simulator); current consumption of the connected camera.
IEC standard-compliant (IEC61000-4-2/3/4/6)
1500 VAC for one minute
Withstand voltage (between the power terminals and the I/O terminals,
and between the external terminals and the case) ❚ Performance specifications - KV-CA1H/CA1W -
50 MΩ or more Model KV-CA1H KV-CA1W
(between the power terminals and the I/O terminals Installation distance 200 mm to ∞ 100 mm to ∞
Insulation resistance
and between the external terminals and the case, Focal distance 3.8 mm (fixed) 1.05 mm (fixed)
with 500 VDC megohmmeter)
Horizontal viewing angle: Horizontal viewing angle:
Intermittent vibration Scan times Approx. 60° Approx. 180°
Field of view
Frequency Acceleration Half amplitude Vertical viewing angle: Vertical viewing angle:
Approx. 47° Approx. 150°
Compliant 5 to 9 Hz – 3.5 mm 10 times in
with Image receiving element 1/2.9 inch colour CMOS
9 to 150 Hz 9.8 m/s2 – each of X, Y,
Vibration resistance JIS B 3502 and Z Resolution 640 (H) × 480 (V) 1280 (H) × 960 (V)
and Continuous vibration
directions Frame rate 10/30/120 fps 10/30 fps
IEC61131-2 Frequency Acceleration Half amplitude (for Internal current consumption*1 70 mA or less
5 to 9 Hz – 1.75 mm 100 min.)
Weight Approx. 90 g Approx. 140 g
9 to 150 Hz 4.9 m/s2 –
Acceleration: 150 m/s2, Application time: 11 ms, *1 Maximum current consumption inside the camera when the power supplied to the CPU unit is
Shock resistance 24 VDC (-15%/+20%). The maximum current consumption inside the camera is 120 mA when
2 times in each of the X, Y, and Z directions
the unit power supplied to the camera is 12 to 24 VDC (-10%/+20%).
*1 Guaranteed range in which the system can be used.
*2 Specified according to the temperature in the control panel on the lower side of the unit.
*3 Supplied via the CPU unit or expansion unit.

❚ General specifications - KV-CA1H/CA1W -


Item Specifications
Operating ambient
0 to +50°C (no freezing)
temperature
Operating ambient humidity 35 to 85% RH (no condensation)
Ambient storage temperature -20 to +60°C (no freezing)
Ambient storage humidity 35 to 85% RH (no condensation)
Pollution degree 3
10 to 500 Hz
Vibration resistance Power spectral density: 0.033 G2/Hz,
Directions of X, Y, and Z
Enclosure rating IP65F*1 *2
*1 The enclosure rating is evaluated with the camera cable connected.
*2 “F” signifies evaluation as oilproof per JIS C 0920.

Dimensions Unit: mm

❚ CPU unit ❚ Camera input unit


KV-8000 KV-CA02
1.4 115 1.1

27.3 27.3

92.5 35.9 92.5 35.9

90 90
R53
56.3 3.9 8 36 3.9
95

16.7 16.7 (185)


❚ Camera
14.9 14.9
KV-CA1H KV-CA1W
ø29 ø33.5
ø28.9 35 ø33.6 41.4

35 47.2
19.6
25.3
R53
16.9
43.7 3.3 R53
28 3.8
28 49 6.7 14 52.4
3.5 14
(155) 57.7
35.3 (163.7)
27.2 4.2 12.3

3 × M3 3 × M3
Depth: 4 max. Depth: 4 max.

28
List of Component Devices

❚ KV-8000 Series
KV-7000C
Category Item name Model Functions/Specifications
required
Program capacity: 1500 k steps, LD command processing speed: 0.96 ns
CPU CPU unit KV-8000 Machine Operation Recorder function –
EtherNet/IP™ port, USB port (USB 2.0), CPU inner bus
Camera input unit KV-CA02 2 ports, for use with KV-CA1x –
Compact standard camera KV-CA1H Colour camera, Resolution: 640 (H) × 480 (V), Frame rate: 10/30/120 fps –
Wide field and
KV-CA1W Colour camera, Resolution: 1280 (H) × 960 (V), Frame rate: 10/30 fps –
high-resolution camera
Camera KV-C5 Cable length: 5 m –
Camera cable KV-C10 Cable length: 10 m –
KV-C20 Cable length: 20 m –
Mounting adapter OP-88386 Mounting stand –
Adjustable bracket OP-88387 For pole-mounting –
KV-B16XC 16 points, 24/5 VDC switchable, screw terminal block 
Input Unit KV-C32XC 32 points, 24/5 VDC switchable, 34-pin MIL connector × 1 
KV-C64XC 64 points, 24 VDC, 34-pin MIL connector × 2, compatible with 2-wire sensor 
KV-B8RC 8 points, relay (independent common), screw terminal block 
KV-B16RC 16 points, relay, screw terminal block 
KV-B16TC 16 points, transistor (sink), screw terminal block 
KV-B16TD 16 points, MOSFET (sink), with overcurrent protection function, screw terminal block 
KV-B16TCP 16 points, transistor (source), screw terminal block 
Output Unit KV-C32TC 32 points, transistor (sink), 34-pin MIL connector × 1 
I/O
KV-C32TD 32 points, MOSFET (sink), with overcurrent protection function, 34-pin MIL connector × 1 
KV-C32TCP 32 points, transistor (source), 34-pin MIL connector × 1 
KV-C64TC 64 points, transistor (sink), 34-pin MIL connector × 2 
KV-C64TD 64 points, MOSFET (sink), with overcurrent protection function, 34-pin MIL connector × 2 
KV-C64TCP 64 points, transistor (source), MIL connector 34 pins × 2 
32 inputs + 32 outputs, 24/5 VDC switchable, 40-pin MIL connector ×2
High-speed I/O Unit KV-SIR32XT –
Unit interrupt, inter-unit synchronisation, with overcurrent protection function
KV-B8XTD 8 inputs + 8 outputs, MOSFET (sink), with overcurrent protection function, screw terminal block 
I/O unit
KV-C16XTD 16 inputs + 16 outputs, MOSFET (sink), with overcurrent protection function, 34-pin MIL connector × 1 
High-speed analogue Voltage, current input 4 ch; conversion speed: 10 μs/ch;
KV-SAD04 –
input unit Resolution: 1/20000; conversion precision: 0.1% (at 25°C ±5°C), unit interrupt, inter-unit synchronisation
High-speed analogue Voltage, current output 4 ch; conversion speed: 10 μs/ch;
Analogue KV-SDA04 –
output unit Resolution: 1/20000; conversion precision: 0.1% (at 25°C ±5°C), unit interrupt, inter-unit synchronisation
Voltage, current input 2 ch + Voltage, current output 2 ch; conversion speed: 80 μs/ch;
Analogue I/O unit KV-AM40V 
Resolution: 1/8000, conversion precision: ±0.2% of F.S. (at 25°C)
Thermocouple and platinum resistance thermometer, voltage, current input: 4 ch;
Multi-input unit KV-TP40 
Temperature conversion speed: 50 ms/4 ch; insulation between channels
Temperature control unit KV-TF40 Thermocouple and platinum resistance thermometer input: 4 ch; PID automatic calibration 
MECHATROLINK-III communication, 16 axes
KV-XH16ML Position control, speed control, torque control, linear interpolation, arc interpolation, helical interpolation, –
and synchronous control, unit interrupt, inter-unit synchronisation, application package
Positioning/ Simplified wiring type
Motion Positioning/motion unit
MECHATROLINK-III communication, 4 axes
KV-XH04ML Position control, speed control, torque control, linear interpolation, arc interpolation, helical interpolation, –
and synchronous control, unit interrupt, inter-unit synchronisation, application package
High-speed positioning unit KV-SH04PL Pulse train, 4-axis, position control, linear interpolation, unit interrupt, and inter-unit synchronisation –
Positioning/ Modbus RTU communication, max. 8 axes
Communication positioning
High-speed KV-LH20V Manufacturers of compatible devices: 
unit
counter KEYENCE; IAI Corporation; ORIENTAL MOTOR Co., Ltd.; SMC Corporation
High-speed counter unit KV-SSC02 2 ch, Max. input frequency: 16 MHz (2 phases quadruple), unit interrupt, inter-unit synchronisation –
2 ports; support for EtherNet/IPTM, EtherCAT® (slave), CC-Link IE Field (intelligent device station), and
PROFINET (device); 1000BASE-T/100BASE-TX/10BASE-T; PLC link function; PROTOCOL STUDIO mode;
Ethernet Unit KV-XLE02 –
FTP client/server function; KV sensor network compatibility; KV socket communication; unit interrupt;
inter-unit synchronisation
KV-XL202 2 ports (RS-232C), PLC link Function, PROTOCOL STUDIO mode, Modbus master/slave –
Serial Communication Unit
KV-XL402 2 ports (RS-422A/485), PLC link Function, PROTOCOL STUDIO mode, Modbus master/slave –
Network
KL-LINK unit KL-N20V Communication speed 5 Mbps, remote I/O mode, PLC link mode 
CC-Link Ver. 2.0, communication speed: 10 Mbps, master unit, master unit (duplex),
CC-Link unit KV-CL20 
standby master unit, local station
DeviceNet unit
TM
KV-DN20 Communication speed 500 kbps, master mode, slave mode, master & slave mode 
FL-net unit KV-FL20V FL-net (OPCN-2) Ver. 2.00 compatible, 100BASE-TX/10BASE-T 
High-speed multi-link unit KV-LM21V High-speed multi-link (for connection to VT Series), serial PLC link 
EtherNet/IPTM support NU-EP1 N-bus supported, PoE supported –
Network Communication unit DL-EP1 D-bus supported –
related EtherNet/IPTM support NE-Q05P 5 ports, 24 VDC, QoS function, PoE function –
Ethernet switch NE-Q05 5 ports, 24 VDC, QoS function –
AC power supply unit
Power supply KV-PU1 Output capacity: 1.8 A; Relay output: rated load of 24 VDC, 0.5 A –
with error output
3 layers (when 1 m extension cable is used, max. 48 units are connectable)
Extension unit KV-EB1 
2 layers (when 2 m extension cable is used, max. 32 units are connectable)
Bus extension
OP-42141 2 m, can use 1 per system –
Extension cable
OP-42142 1 m, can use 2 per system –
Connection
Bus-connected unit KV-7000C For connection of a KV-5000/3000 Series expansion unit, with end unit –
conversion
Battery KV-B1 For calendar clock saving, mounted to battery case on front of CPU –
Related
KV-M16G SDHC standard, industrial specification, 16 GB –
products SD memory card
KV-M4G SDHC standard, industrial specification, 4 GB –

29
List of Component Devices

❚ KV-8000 Series
Category Category/Item name Model Functions/Specifications
Communication unit KV-EP02 2 ports, EtherNet/IPTM, 100BASE-TX/10BASE-T
KV-NC16EX 16 points, 24/5 VDC switchable, 20-pin MIL connector × 1
KV-NC16EXE 16 points, 24/5 VDC switchable, European terminal block
KV-NC32EX 32 points, 24/5 VDC switchable, 34-pin MIL connector × 1
KV-NC8ER 8 points, relay output, European terminal block
KV-NC16ET 16 points, transistor (sink) output, 20-pin MIL connector × 1
I/O unit KV-NC16ETP 16 points, transistor (source) output, 20-pin MIL connector × 1
(Connector) KV-NC16ETE 16 points, transistor (sink) output, European terminal block
KV-NC16ETPE 16 points, transistor (source) output, European terminal block
KV-NC32ET 32 points, transistor (sink) output, 34-pin MIL connector × 1
KV-NC32ETP 32 points, transistor (source) output, 34-pin MIL connector × 1
KV-NC16EXT 16 inputs/16 outputs, transistor (sink) output, 34-pin MIL connector × 1
KV-NC32EXT 32 inputs/32 outputs, transistor (sink) output, 34-pin MIL connector × 2
KV-N8EX 8 points, 24/5 VDC switchable, screw terminal block
KV-N16EX 16 points, 24/5 VDC switchable, screw terminal block
KV-N8ER 8 points, relay output, screw terminal block
EtherNet/IPTM
KV-N8ET 8 points, transistor (sink) output, screw terminal block
I/O unit KV-N8ETP 8 points, transistor (source) output, screw terminal block
(Terminal block) KV-N16ER 16 points, relay output, screw terminal block
KV-N16ET 16 points, transistor (sink) output, screw terminal block
KV-N16ETP 16 points, transistor (source) output, screw terminal block
KV-N8EXR 8 inputs/8 outputs, relay output, screw terminal block
KV-N8EXT 8 inputs/8 outputs, transistor (sink) output, screw terminal block
Voltage, current input 4 ch; conversion speed: 80 μs/ch;
KV-NC4AD
Resolution: 1/4000; conversion precision: 0.3% (at 25°C ±5°C); European terminal block
Analogue unit Voltage, current output 2 ch; conversion speed: 80 μs/ch;
KV-NC2DA
(Connector/terminal block) Resolution: 1/4000; conversion precision: 0.3% (at 25°C ±5°C); European terminal block
Voltage, current input 2 ch / Voltage, current output 1 ch; conversion speed: 80 μs/ch;
KV-N3AM
Resolution: 1/4000; conversion precision: 0.3% (at 25°C ±5°C); screw terminal block
Thermocouple and platinum resistance thermometer 4 ch, conversion speed: 125 ms/ch,
Temperature input unit KV-NC4TP
Remote I/O European terminal block
Connection conversion unit KV-NC1 For connecting screw terminal block type expansion units
KL-8BLX 8 inputs, 24/5 VDC switchable, screw terminal block
KL-16BX 16 inputs, 24/5 VDC switchable, screw terminal block
KL-16CX 16 inputs, 24/5 VDC switchable, 26-pin MIL connector × 1 (included)
KL-32CX 32 inputs, 24/5 VDC switchable, 26-pin MIL connector × 2 (included)
KL-8BLR 8 outputs, relay, screw terminal block
KL-8BLT 8 outputs, transistor (sink), screw terminal block
I/O unit
KL-16BR 16 outputs, relay, screw terminal block
KL-16BT 16 outputs, transistor (sink), screw terminal block
KL-16CT 16 outputs, transistor (sink), 26-pin MIL connector × 1 (included)
KL-LINK KL-32CT 32 outputs, transistor (sink), 26-pin MIL connector × 2 (included)
KL-8BXR 8 inputs + 8 outputs, relay, screw terminal block
KL-8BXT 8 inputs + 8 outputs, transistor (sink), screw terminal block
KL-4AD Voltage, current input 4 ch; resolution: 1/4000; with 4-digit 7 segment display
KL-2DA Voltage, current output 2 ch; resolution: 1/4000; with 4-digit 7 segment display
Analogue unit
KL-DC1A Direct current input 1 ch, resolution: 1/200000, with 4-digit 7 segment display
KL-DC1V Direct voltage input 1 ch, resolution: 1/200000, with 4-digit 7 segment display
Temperature control unit KL-2TF Thermocouple/platinum resistance thermometer input 2 ch
Load cell unit KL-LC1 Load cell input 1 ch, resolution: 1/20000, with 4-digit 7 segment display
Power unit KL-WH1 Electricity amount measurement 1 ch, with 4-digit 7 segment display
KV-RC16BX 16 inputs, 24/5 VDC switchable, screw terminal block
KV-RC32BX 32 inputs, 24/5 VDC switchable, screw terminal block
KV-RC16BR 16 outputs, relay, screw terminal block
KV-RC16BT 16 outputs, transistor (sink), screw terminal block
I/O unit
KV-RC32BT 32 outputs, transistor (sink), screw terminal block
CC-Link
KV-RC8BXR 8 inputs + 8 outputs, relay, screw terminal block
KV-RC8BXT 8 inputs + 8 outputs, transistor (sink), screw terminal block
KV-RC16BXT 16 inputs + 16 outputs, transistor (sink), screw terminal block
KV-RC4AD Voltage, current input 4 ch; resolution: 1/12000; with 5-digit 7 segment display
Analogue unit
KV-RC4DA Voltage, current output 4 ch; resolution: 1/12000; with 5-digit 7 segment display

❚ Software
Category Item name Model Functions/Specifications

Programming support software KV STUDIO Ver. 10 KV-H10G DVD-ROM, Windows 10/8/7-compatible, site licence*

Dedicated software for replay mode KV REPLAY VIEWER – Windows 10/8/7-compatible, downloadable for free from website

* Through user registration, the software can be used by multiple people associated with the office (including factories, business offices, and sales offices) that purchased the software.

❚ Software operating environment


Software Supported OS Required free space on hard disk
KV STUDIO
Windows 10/8 (including 8.1)/7 (SP1 or higher) 2000 MB or more
KV REPLAY VIEWER

30
❚ Accessories
Category Related models Overview Model Functions/Specifications
CPU KV-8000 USB cable OP-35331 Cable length: 3 m
OP-22184 Equipped with a 40-pin standard contact, vertical type
KV-SIR32XT MIL connector
OP-51404 Equipped with a 40-pin standard contact, diagonal type
KV-C32 MIL connector OP-23139 Equipped with a 34-pin standard contact, vertical type
I/O KV-C32/C64 MIL connector OP-42224 Equipped with a 34-pin standard contact, diagonal type
OP-22186 For standard AWG22-24, 200 pieces
Contact
Common OP-30594 For fine line model AWG26-28, 200 pieces
Pressure welding tool OP-21734 For MIL connector
OP-22184 Equipped with a 40-pin standard contact, vertical type
MIL connector
Positioning/ OP-51404 Equipped with a 40-pin standard contact, diagonal type
KV-SH04PL/
High-speed OP-22186 For standard AWG22-24, 200 pieces
KV-SSC02 Contact
counter OP-30594 For fine line model AWG26-28, 200 pieces
Pressure welding tool OP-21734 For MIL connector
Temperature
KV-TF40 Current sensor (CT) OP-6694 For heater wire breaking alarm
adjustment
OP-79426 CC-Link Ver. 1.10 compatible, 20 m cable
CC-Link Common Communication cable
OP-79427 CC-Link Ver. 1.10 compatible, 100 m cable
MIL connector OP-30593 Equipped with a 26-pin standard contact
KL-16C/ OP-22186 For standard AWG22-24, 200 pieces
Contact
KL-32C OP-30594 For fine line model AWG26-28, 200 pieces
Pressure welding tool OP-21734 For MIL connector
KL-16C/32C/ OP-30588 Space-saving mounting bracket (vertical direction)
Mounting bracket
KL-8BXT/8BXR/ OP-30589 Used for mounting screw
KL-4AD/2DA Series connection cable OP-30590 Used in situations where multiple slave stations are used in the same location.
KL-8BXR OP-33011 Relay PCB (8 ch)
Relay for replacement
KL-16BR OP-30595 Relay PCB (16 ch)
KL-8BL Series connection cable OP-32985 Used in situations where multiple slave stations are used in the same location.
KL-LINK
KL-8BLR Relay for replacement OP-33010 5 relays, with extraction tool
KL-2TF Current sensor (CT) OP-6694 For heater wire breaking alarm
KL-DC/LC/WH Attachment OP-51667 Panel mounting bracket (2 brackets included)
OP-51674 50 A
KL-WH Current sensor (CT) OP-51675 100 A
OP-51676 250 A
OP-30591 KPEV-SB (1P) 0.75 mm2 20 m
Communication cable
OP-30592 KPEV-SB (1P) 0.75 mm2 100 m
Common
Adapter KL-B1 Adapter for joint cable
Branch unit KL-T1 Used with T-branching
Connection
KV-7000C End unit OP-84203 Included with KV-7000C
conversion

31
RELATED PRODUCTS

Programmable controller

Package type KV Nano Series

High speed and high performance in a compact PLC

❙ Terminal board type and connector type are available


❙ 14-point to 60-point types can be selected according to the application
❙ USB port included as standard
❙ Battery-less

Touch panel display

Touch panel display VT5 Series


Large type VT5-X / Small, Medium type VT5-W

Advanced graphics and usability

❙ Overwhelming display performance with 16 million colours


❙ All sizes use high resolution LCD
❙ Voice output function with multi-language support
❙ Automatic translation into multiple languages

Frequently Asked Questions

www.keyence.com/controlfaq

SAFETY INFORMATION
Please visit: www.keyence.com Please read the instruction manual carefully in
order to safely operate any KEYENCE product.

GLOBAL NETWORK CONTACT YOUR NEAREST OFFICE FOR RELEASE STATUS

AUSTRIA CZECH REPUBLIC INDIA MALAYSIA ROMANIA TAIWAN


Phone: +43 2236 378266 0 Phone: +420 220 184 700 Phone: +91-44-4963-0900 Phone: +60-3-7883-2211 Phone: +40 269 232 808 Phone: +886-2-2721-8080

BELGIUM FRANCE INDONESIA MEXICO SINGAPORE THAILAND


Phone: +32 15 281 222 Phone: +33-1-56-37-78-00 Phone: +62-21-2966-0120 Phone: +52-55-8850-0100 Phone: +65-6392-1011 Phone: +66-2-369-2777

BRAZIL GERMANY ITALY NETHERLANDS SLOVAKIA UK & IRELAND


Phone: +55-11-3045-4011 Phone: +49-6102-3689-0 Phone: +39-02-6688220 Phone: +31 40 20 66 100 Phone: +421 2 5939 6461 Phone: +44 1908-696-900

CANADA HONG KONG JAPAN PHILIPPINES SLOVENIA USA


Phone: +1-905-366-7655 Phone: +852-3104-1010 Phone: +81-6-6379-2211 Phone: +63-2-981-5000 Phone: +386 1 4701 666 Phone: +1-201-930-0100

CHINA HUNGARY KOREA POLAND SWITZERLAND VIETNAM


Phone: +86-21-5058-6228 Phone: +36 1 802 73 60 Phone: +82-31-789-4300 Phone: +48 71 36861 60 Phone: +41 43 455 77 30 Phone: +84-24-3772-5555

The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice. WW1-1039
Company and product names mentioned in this catalogue are either trademarks or registered trademarks of their respective companies. Unauthorised reproduction of this catalogue is strictly prohibited.
Copyright © 2019 KEYENCE CORPORATION. All rights reserved. KV8000-WW-C-GB 1079-1 600T82