Comparativo 320 Vs 390

This document provides a comparison of parameter differences between two files, PARAME~2 and MAQ, for a drive application. It lists over 100 parameters, their values in each file, and any notes on differences between the files. The parameters cover settings for the drive application, motor values, I/O configuration, and backup parameter values.

Uploaded by

Juan Del Fabro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
83 views2 pages

Comparativo 320 Vs 390

This document provides a comparison of parameter differences between two files, PARAME~2 and MAQ, for a drive application. It lists over 100 parameters, their values in each file, and any notes on differences between the files. The parameters cover settings for the drive application, motor values, I/O configuration, and backup parameter values.

Uploaded by

Juan Del Fabro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 2

[DRIVEWINDOW 2.

0 Parameter Difference File]


2019-11-05 12:37:21

Name File: PARAME~2 File: MAQ Note


Application Base library FFFFF.002 1.020
Application Name ASARF018 ASAR730S
Application Version 11-06-14 12:34:48:546 07-01-24 15:39:29:717
10.01: EXT1 MAR/PARO/DIR ED1P,2P,3 ED1
10.09: SLS ACTIVE NO Does not exist in file MAQ
11.03: SELEC REF EXT1 ED5A,6D EA2
11.05: REF EXT1 MAXIMO [rpm] 1500 1150
12.01: SEL VELOC CONST ED5,6 SIN SEL
13.09: FILTRO EA2 [s] 0.099999994 1.2
14.01: SALIDA RELE SR1 LISTO FALLO (-1)
14.03: SALIDA RELE SR3 FALLO (-1) PARAM 14.18
14.18: SAL RELE PUNTERO3 0X0 0X5413
16.12: RESET COUNTER NO Does not exist in file MAQ
20.01: VELOCIDAD MINIMA [rpm] -1000 0
20.02: VELOCIDAD MAXIMA [rpm] 1000 1149.9988
20.03: INTENSIDAD MAXIMA [A] 642.32947 654.98352
20.04: LIM1 PAR MAXIMO [%] 300 200
20.05: CTRL SOBRETENSION SI NO
20.22: SLS SPEED LIMIT [rpm] 0 Does not exist in file MAQ
22.01: SEL ACEL/DECEL ED4 ACE/DEC 1
22.02: TIEMPO ACELER 1 [s] 20 5
22.03: TIEMPO DECELER 1 [s] 20 5
22.10: SLS ACCELER TIME [s] 19.999981 Does not exist in file MAQ
22.11: SLS DECELER TIME [s] 19.999981 Does not exist in file MAQ
23.01: GANANCIA 9.9999905 29.999969
23.02: TIEMP INTEGRACION [s] 2.5000572 1.1999607
23.04: COMPENSACION ACE [s] 0 8.9999428
23.07: TIEMP FILT VELACT [ms] 7.9870224 66.876404
26.07: FLYSTART CUR REF [%] 50 Does not exist in file MAQ
26.08: FLYSTART INIT DLY 25 Does not exist in file MAQ
26.09: FS METHOD OFF Does not exist in file MAQ
30.01: EA<FUNCION MINIMA FALLO NO
30.04: PROT TERMICA MOT NO FALLO
30.05: MODO PROT TERM MO DTC TERMISTOR
30.06: TIEMPO TERM MOTOR [s] 5583.5723 6285.4766
30.12: TIEMPO BLOQUEO [s] 19.999981 14.999926
30.23: ALARMA LIMITE 0X0 0X3
31.01: NUMERO TENTATIVAS 0 5
31.03: TIEMPO DE DEMORA [s] 0 1
31.06: SUBTENSION NO SI
32.01: FUNCION VELOC 1 NO LIMITE BAJO
32.02: LIMITE VELOC 1 [rpm] 0 60
33.01: VERSION SW AS7R7364 AS7R7292
33.02: VERSION SW APLI ASARF018 ASAR730S
34.04: FILTRO VEL ACT [ms] 499.96375 99.897385
34.05: FILTRO PAR ACT [ms] 100.0166 9.894371
35.08: MOT MOD COMP PTR 0X0 Does not exist in file MAQ
45.02: ENERGY TARIFF1 [c/E] 0 Does not exist in file MAQ
45.06: E TARIFF UNIT EUR Does not exist in file MAQ
45.08: PUMP REF POWER [%] 100.00003 Does not exist in file MAQ
45.09: ENERGY RESET DONE Does not exist in file MAQ
70.05: CH2 DDCS HW CON ANILLO Does not exist in file MAQ
72.13: FREC CARGA 4 [%] 59.999939 59.999825
83.01: MODO PROG ADAPT EDITAR MARCHA
84.01: ESTADO 0X8 0X2
84.05: BLOCK1 NO COMPARE
84.06: ENTRADA 1 0X0 0X102
84.07: ENTRADA 2 0X0 0X400414
84.09: SALIDA 0X0 0X4
84.10: BLOCK2 NO TON
84.11: ENTRADA 1 0X0 0X10115
84.12: ENTRADA 2 0X0 0X403A98
84.15: BLOCK3 NO AND
84.16: ENTRADA 1 0X0 0X25409
84.17: ENTRADA 2 0X0 0X540E
84.18: ENTRADA 3 0X0 0X830302
95.03: INT CONFIG USER 1 0
95.11: SUPPLY CTRL MODE LINE CONV Does not exist in file MAQ
95.12: LCU RUN PTR 0X0 Does not exist in file MAQ
99.02: MACRO APLICACION CTRL SEC FABRICA
99.06: INTENS NOM MOTOR [A] 358.99994 478.99127
99.07: FREC NOM MOTOR [Hz] 50.000015 50.000015 Display formats differ.
99.08: VELOC NOM MOTOR [rpm] 990.97485 990.99878
99.09: POTENCIA NOM MOT [kW] 199.99982 249.99976
99.11: NOMBRE APARATO Centrifugal
101.03: Parameter 101.03 Backup Centrifugal
110.02: Parameter 110.02 Backup 358.99994 478.99127
110.03: Parameter 110.03 Backup 50.000015 50.000015 Display formats differ.
110.04: Parameter 110.04 Backup 990.97485 990.99878
110.06: Parameter 110.06 Backup 199.99982 249.99976
110.07: Parameter 110.07 Backup 0.84975612 0.79156613
112.02: Parameter 112.02 Backup 350.99982 422.99988
190.07: Parameter 190.07 Backup 0.82015991 0.8392334
191.01: Parameter 191.01 Backup 0X126C6 0X13D42
191.04: Parameter 191.04 Backup 0X6F826 0X97A92
191.05: Parameter 191.05 Backup 0XFF7312 0XFF7393
191.06: Parameter 191.06 Backup 0X460D 0X3E42
191.07: Parameter 191.07 Backup 0X460D 0X3E42
191.09: Parameter 191.09 Backup 0X457BD 0X327A5
191.10: Parameter 191.10 Backup 0X56DAF 0X3F18E
191.11: Parameter 191.11 Backup 0X457BF 0X327A5
191.18: Parameter 191.18 Backup 0X791FE4 0X79D1C6
191.19: Parameter 191.19 Backup 13.21838 8.7004662
192.01: Parameter 192.01 Backup 0X119 0X19
192.03: Parameter 192.03 Backup 0X60509E 0X285C9E
192.04: Parameter 192.04 Backup 0XB0C601 0XB0E601
192.06: Parameter 192.06 Backup 0X4985F 0X6218F
192.09: Parameter 192.09 Backup 0X144B9 0X144BB
192.10: Parameter 192.10 Backup 0X6CC4CF 0X65520A
192.11: Parameter 192.11 Backup 0X28F5C 0X33333
192.13: Parameter 192.13 Backup 0XCBC9 0X8E4C
192.15: Parameter 192.15 Backup 0XFFEF11 0X2B9
192.16: Parameter 192.16 Backup 0X7C 0X378
Properties Control Board Type RMIO-1x RMIO
Properties Name ACS 800 0320_3MR Centrifugal
Properties Product Family ACS 800 0320_3MR ACS 800 0390_3MR