Thermowell Velocity Calculations
TW-2010 Ver. 1.4 (Beta)
Company: BHP Tag No: TW6151A
Project No: GEP Termowell Analysis Date: 19/09/2019
Reference: Rev:
L
b
t
PROCESS DATA FREQUENCY LIMIT
Fluid G Gas Natural Frequency (fn) 379 Hz
Operating Temperature T 400 °F Wake Frequency (fs) 243 Hz
Operarating Pressure P 1335 psi Frequency Ratio (fs/fn) 0.64
Fluid Velocity * V 69.0 ft/s Frequency Criteria fs < 0.4 • fn
Density r 3.330 lb/ft³ Wake Frequency Limit 151 Hz FAIL
Viscosity (Dynamic) µ 10.08 lb/ft-s x 10-6 Wake Freq exceeds W F Limit
(Dynamic = Kinematic x Density)
* Velocity can be calc from Flow Rate & Pipe ID PRESSURE STRESS
(See equation on S3) Pressure Limit 1,480 psi
Max Operating Pressure 1,335 psi
WELL DATA Safety Factor 1.1 PASS
Mounting F Flanged (Flange incl in Pressure Calc) Yes
Shank S Straight
Unsupported Length L 13.0 in STEADY-STATE STRESS
Root Diameter A 1.500 in Stress Limit 28,950 psi
Tip Diameter B 0.750 in Stress @ Design Velocity 590 psi
Bore Diameter d 0.260 in Safety Factor 49.0 PASS
Fillet Radius at Root b 0.000 in
Min Tip Thickness t 0.250 in DYNAMIC STRESS
Shielded Length Lo 7.3 in Stress Limit 5,055 psi
N.R. Stress @ Design Velocity 1,571 psi
N.R. Safety Factor 3.2 PASS
Flange Rating (ref S3) Pf 1480 psi
Mtg Code (ref S2) FS FS Cyclic Stress @ In-Line Resonance
Material 13 13 316 Fluid Velocity (for In-L Resonance) 43 fps
Modulus of Elasticity E 26.5 psi x 10-6 In-Line Stress Calculation Required
Allowable Stress S 19.3 psi X 10-3 Stress @ In-L Resonance 35,820 psi
Fatigue Stress Limit Sf 5.40 psi X 10-3 Safety Factor 0.1 FAIL
Well Density Pm 0.286 lb/in³ Installed Nat'l Freq shall satisfy: fs < 0.4•fn