Positive Displacement Oil Flowmeters (Mechanical Indicator Type)
Overview
TOKICO has a long history of producing high quality flow meters since 1950 in the fuel measurement field. Our
flowmeters are used in a wide variety of applications including measuring of boiler fuel oil and diesel oil, as well as
for transactions for kerosene, light oil and heavy oil. We have been serving numerous customers with accurate,
compact, and excellent durability flowmeters.
Features
● High accuracy
Accuracy is within ±0.5%
Fluid is directly measured by gear or roots, enabling accurate measuring.
● Compact design
The flowmeter is compactly designed, yet the indicator is easy to read.
● Excellentdurability
Simple structure enables long term durability with virtually no degradation of accuracy.
FGB Type
Size :15mm (1/2B) ~ 25mm (1B)
・Suitable for small volume flow between 40 ~
3000L/h ・Employs gear-type rotors made of resin
FRO Type
Size : 40mm (11/2B) ~ 50mm (2B)
・Suitable for medium volume flow between 0.8 ~ 15 m3/h (800 ~
15,000L/h) ・Employs roots rotors made of aluminum alloy ・Roots rotors
rotate without physical contact
⇒ Extremely low pressure loss
⇒ Accuracy remains unchanged over a long period of time
FRP Type FRA Type
Size : Size :150mm (6B)
80mm (3B) ~
100mm (4B)
(Flow range : 0.6 ~ 130m3/h) (Flow range : 5 ~ 200m3/h)
・Suitable for large volume fl ow
・Employs roots rotors made of cast iron
・ Roots rotors rotate without physical contact
⇒ Extremely low pressure loss
⇒ Accuracy remains unchanged over a long period of time
-1-
Standard Specifications
FGB type FRO Type FRP/FRA type
Accuracy ±0.5%
Flow range Refer to next page
Max. working pressure 1MPa
Hydraulic test pressure 2MPa
1
Size /2B Gasoline ,Kerosene, Diesel /Light oil
--Kerosene, diesel/light oil, (With AC7A rotor) :50℃
Max. working temperature A heavy oil : 80℃ Kerosene, diesel/light oil : 50℃ Diesel /Light oil, A,B,C heavy oil
Size 3/4B & 1B : A, B, C heavy oil : 100℃ (With FC200 rotor) :100℃
--Kerosene, diesel/light oil, : 80℃ With Cooling fin
--A,B,C heavy oil : 120℃ (Rotor material: FC200 rotor) :150℃
Flange rating JIS10K FF
1
Size /2B : FC250 (Cast iron)
Body FC 250 (Cast iron) FC 250 (Cast iron)
Size 3/4B & 1B : FCD400 (Ductile iron)
Material
Size 1/2B : Phenol resin ADC12 FC (Cast iron)or
Rotor
Size 3/4B & 1B : PPS resin (Alluminum alloy die cast) AC7A (Aluminum alloy)
04X : Totalizing counter (7 digits), 02X2 : Totalizer only(7 digits)
Counter unit Reset counter (5 digits) 04X2 : Totalizer (7 digits)with
02X : Totalizing counter (7 digits) zero reset(5 digits)
Transmitter Reed switch (02S, 04S) Microswitch (02M, 04M)
Electrical ・Non-contact type (F)
Output pulse Max. 10Hz Max. 5Hz
transmitter Contact life time 10 million times 5 million times ・Reed switch type (S) (R)
unit ・Microswitch type (M)
Cable Double core shield cable Double core shield cable
Flow direction Right → Left (Standard)
Painting color Munsell 1.4PB 3.1/1.2
※ ±0.2 % accuracy are available optionally for FRP/FRA type with Easy - Change Gear Type Accuracy Adjuster(02X3 and 04X3) with special indent order only.
Pressure Loss Characteristics
FGB Type
Pressure loss (MPa)
conn.size 1/2B
conn.size 3/4B
conn.size 1B
Flow rate(m3/h)
FRO Type FRP/FRA Type
Pressure loss (MPa)
Pressure loss (MPa)
conn.size 11/2B
conn.size 2B
Flow rate(%)
Flow rate(m3/h)
-2-
Flow range
Flow range (L/h)
Model Condition Kerosene Diesel, Light oil A Heavy oil B,C Heavy oil
(1.5mPa・s) (5mPa・s) (10mPa・s ~) (50 ~ 300mPa・s)
FGBB423BAL Standard - 40 ~ 200 - -
FGBB631BDL Standard 150 ~ 1250 120 ~ 1250 40 ~ 1250 20 ~ 1250
FGBB835BDL Standard 150 ~ 3000 150 ~ 3000 100 ~ 3000 40 ~ 3000
Flow range (m3/h)
Model Condition
Kerosene, Light oil (0.9 ~ 5mPa・s) Heavy oil (5 ~ 300mPa・s)
Intermittent 0.8 ~ 7.0 0.1 ~ 7.0
FRO0438
Continuous 0.8 ~ 4.5 0.1 ~ 6.0
Intermittent 1.5 ~ 15.0 0.25 ~ 15.0
FRO0541
Continuous 1.5 ~ 9.0 0.25 ~ 13.0
Flow range (m3/h)
Model Condition Gasoline/Kerosene Light oil A,B Heavy oil C Heavy oil
(0.3 ~ 2mPa・s) (2 ~ 5mPa・s) (5 ~ 150mPa・s) (150 ~ 500mPa・s)
Intermittent 5 ~ 35 3.5 ~ 40 0.6 ~ 40 0.6 ~ 35
FRP0845BAA
Continuous 5 ~ 25 3.5 ~ 35 0.6 ~ 35 0.6 ~ 25
Intermittent 16 ~ 120 12 ~ 130 4 ~ 130 4 ~ 120
FRP1051BAA Continuous 16 ~ 85 12 ~ 120 4 ~ 120 4 ~ 85
Intermittent 35 ~ 180 15 ~ 200 8 ~ 200 5 ~ 200
FRA1554BAA Continuous 35 ~ 120 15 ~ 180 8 ~ 180 5 ~ 180
Dimensions
FRP0845BAA L 147 A2 A1
FGBB631BDL
FGBB835BDL
FRP1051BAA
Dφ
(-02X2-X)
(-02X, -04X)
(-04X2-X)
FRO0438 FRA1554BAA
FRO0541
Dφ
(-02X2-X)
(-02X, -04X) (-04X2-X)
A1 A2
L
Size Dimensions (mm) Approx.
Model Model number
mm inch φD L A1 A2 weight (kg)
1
FGBB423BAL - 02X, 04X 15 /2 95 130 181 6
3
FGB Type FGBB631BDL - 02X, 04X 20 /4 100 170 --- 122 7
FGBB835BDL - 02X, 04X 25 1 125 200 133 10
1
FRO0438 - 02X, 04X 40 1 /2 140 200 77 177 17
FRO Type FRO0541 - 02X, 04X 50 2 155 250 99 190 20
FRP0845BAA - 02X2-X, 04X2-X 80 3 185 300 89 170 45
FRP Type
FRP1051BAA - 02X2-X, 04X2-X 100 4 210 450 180 275 100
FRA Type FRA1554BAA - 02X2-X, 04X2-X 150 6 280 560 355 340 250
-3-
Specifications
Model Number Indicator Transmitter
Conn.
Model size Standard Pointer Totalizer Reset Trans-
Base code (with zero Totalizer With pulse ( /rev) Counter Type mission
(mm) (inch) reset) only transmitter digits unit digits unit unit (L/P)
1
15 /2 FGBB423BAL- □□□
0.1(std.)
1L 1L 1L Reed
FGB 3 -02S or 1
20 /4 FGBB631BDL- □□□ -04X -02X switch
Type -04S
(S)
25 1 FGBB835BDL- □□□
40 11/2 FRO0438- □□□ 10L 10L 10L Micro- 1(std.)
FRO -02M or 10
Type -04X -02X -04M 7 5 switch
50 2 FRO0541- □□□ (M)
80 3 FRP0845BAA- □□□□ - X
FRP 100L 100L 100L 0.1(F)
- □□ F □ -X
Type 100 4 FRP1051BAA □□□□ - X - □□ R □ -X 4 types 10 (R,S,M)
-04X2-X -02X2-X - □□ S □ -X (F,R,S,M)
FRA - □□ M □ -X 1(F)
Type 150 6 FRA1554BAA □□□□ - X 1kL 1kL 1kL 100 (R,S,M)
Indicator
Conn. Model Number
Model size Standard
Totalizer only With pulse transmitter
(mm) (inch) (with zero reset)
04X 02X 02S
1
15 /2
3
FGB 20 /4
25 1
04X 02X 02M
40 1 1 /2
FRO
50 2
04X2-X 02X2-X 02F2
80 3
FRP
100 4
04X2-X 02X2-X 02F2
FRA 150 6
-4-
Strainer
Strainers must be used together with fl owmeters.
We have various sizes to suit all flowmeters.
Model numbers
Base code Size (mm / inch) Max. Flowrate (m3 / h) Max. Pressure Material
1
FSYB426BAP 15 /2 0.4
3
1MPa
FSBB632BAP 20 /4 2
FSBB839DAP 25 1 10
2MPa Body: FC250
FSB0439DAP 40 1 1 /2 10
Screen: SUS304
FSB0542BAP 50 2 20
FSB0848BAP 80 3 80
1MPa
FSB1051BAP 100 4 150
FSB1553BBK 150 6 280 Body: STPG370
Standard Specifications
Size 15mm (1/2 B) ~ 150mm (6B)
Max. working pressure BAP : 1Mpa, DAP : 2MPa
Flange rating BAP : JIS10K, DAP : JIS20K
Body FC250 or STPG370
Material Screen SUS304
Gasket Non-asbestos, teflon
80 mesh Viscosity less than 10mPa・s
Screen
40 mesh Viscosity more than 10mPa・s
Dimensions
Size Dimensions
Model number Approx. weight
(mm) (inch) L H H1 φB
1
FSYB426BAP 15 /2 125 --- 70 --- 2
3
FSBB632BAP 20 /4 180 147 110 62 7
FSBB839DAP 25 1 295 258 163 160 15
1
FSB0439DAP 40 1 /2 295 258 163 160 16
FSB0542BAP 50 2 320 290 185 185 22
FSB0848BAP 80 3 395 373 252 230 41
FSB1051BAP 100 4 460 480 325 295 67
FSB1553BAP 150 6 560 800 560 267 115
B
L
H
1
15mm (1/2B) 20mm (3/4B) ~ 100mm (4B)
150mm (6B)
-5-
Precautions on piping and operation
(1) Dirt and particles inside the piping cause problem to the flowmeter. Take special care when installing to
new piping, since new piping may have welding debris.
(2) A strainer must be installed at the up-stream of the flowmeter, as shown in below fi gure. This is to prevent
the problem stated in (1) above. Also, prepare a by-pass line for the convenience of flowmeter disassembly
and maintenance.
(3) Indicator must be installed at eye level and must not face upwards.
(4) Make sure to align actual flow direction with flowmeter's flow direction.
(5) Use the flowmeter within the specification written on the name plate.
Horizontal installation Vertical installation
(Flow direction : Right ⇒ Left) (Flow direction : Bottom ⇒ Top)
Flowmeter Strainer
By-pass Flowmeter
Strainer
By-pass
Inquiry
Please inform us the following when quotation is necessary.
No. Item Contents
1 Application Poduction control, transaction, receipt and shipment, etc.
2 Fluid Name, composition, corrosive or not
3 Flow rate Maximum, normal, minimum
4 Fluid temperature Maximum, normal, minimum
5 Fluid pressure Maximum, normal, minimum
6 Viscosity and specific gravity Viscosity at ℃ , Specific gravity at ℃
7 Connection rating Connection size, flange standard, etc.
8 Flow direction Left ⇒ Right, Right ⇒ Left, Bottom ⇒ Top, Top ⇒ Bottom