  • Features and Overview
  • Operation
  • Specifications
  • Typical Installation

Edwards Donnelly Chute

Indicator and Control System

Features
• Non-Contact Ultrasonic
• 2 Line Alpha Numeric LCD
• Front Panel Pushbutton Control
• Menu Driven Configuration
• 2 Alarms (high and low levels)
• 4 - 20 mA Process Signal
• Zero Maintenance
• Low Installation Cost
• Extremely Accurate
Control Unit • Simple, Reliable, and Easy to Operate

Operation
The ChokeMaster™ is a non-contact level measurement and control system comprised
of a Control Unit and Transducer designed specifically for determining and controlling the
height of cane in a Donnelly Chute. This system provides precise measurement utilizing
proven time-of-flight non-contact ultrasonic technology.

The function of the Control Unit is to precisely measure the time period between the
transmitted echo pulse and the reflected echo pulse to determine the exact level of the cane.
A series of digital software algorithms fine-tune the returned echo to ensure the correct return
echo pulse is monitored. The Control Unit electronics are housed in a NEMA 4X (IP65)
dustproof and waterproof enclosure and include a 2 line alpha-numeric LCD, two
alarm/control relays, and a 4 - 20 mA output signal capable of controlling speed of
conveyors, steam turbines or hydraulic drive systems, etc.

The Transducer is made of impact resistant non-metallic polyvinylcloride (PVC) except for
the face; which is a layered acoustically matched impedance polyurethane material designed
to enhance the transmitted echo pulse while maximizing sensitivity to the return reflected
echo pulse. The Transducer will be delivered installed in an abrasion resistant Positioning
Tube and 'tuned' according to each installation requirements prior to shipment from the
factory. Mounting hardware is also provided. Please review the ChokeMaster™ Sizing
and Selection criteria on document EEC 10033. A 100 foot coaxial cable is provided to
connect the Transducer to the Control Unit along with mounting hardware to install the
Positioning Tube.
Transducer (shown without
Typical Installation Positioner Tube for clarity)

5”
(127mm) 3.4 ft

Control Unit 7”
(178mm)

Specifications

Control Unit:
Temperature Range -22° to 150°F, -30° to 65°C
Power Requirement 115 Volts AC +/- 10%: 50-60 Hz
Output 4 - 20 mA DC 750 ohms max.
2 SPDT Relays; 5A Resistive @ 115/230 Volts AC
Accuracy +/- 0.25% of span
Enclosure Two conduit entries. Four mounting holes for wall mounting
Rating NEMA 4X (IP65) Dustproof and waterproof
Net Weight 3.7 lbs., 1.68 kgs.
Transducer:
Beam Angle 5° @ - 3db
Temperature Range 0° to 160°F, -18° to 71°C
Sensing Distance 1.6 ft. - 10 ft,
0.49 - 3.0 meters
Construction PVC Body; Polyurethane Face
Mounting As required

Main Office New Orleans Office Latin America Office


6380 N. Eldridge Parkway, Unit 102 Tel: +(1) 504-828-3661 Tel: +(52) 5-575-1804
Houston, TX 77041 USA Fax: +(1) 504-828-8970 Fax: +(52) 5-575-1804
Tel: +(1) 713-849-6825 Email: linda@[Link] Email: mmotab@[Link]
Fax: +(1) 713-849-5638
Email: info@[Link]
[Link]

Distributed by:

Edwards Engineering
EDW10010/8.00

You might also like