The document describes a cannulated drill used for holding K-wires or in intramedullary interlocking nail surgery. It provides specifications for the drill such as power output, speed, torque, noise level, and sterilization temperature. Standard accessories, warranty, advantages, and notes for use are also listed.

Uploaded by

Jordan Bonnett
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
630 views6 pages

Motor Electrico Bojin J4103 - B User Manual

The document describes a cannulated drill used for holding K-wires or in intramedullary interlocking nail surgery. It provides specifications for the drill such as power output, speed, torque, noise level, and sterilization temperature. Standard accessories, warranty, advantages, and notes for use are also listed.

Uploaded by

Jordan Bonnett
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

J4103 / B Cannulated drill

Contact Us
Domestic:+86-021-66526503
Export: +86-021-66308078
+86-021-66527863
[email protected]
Office : Room 606, NO.3388, GongHeXin Road, Shanghai,
China
Application:

Holds K-wires or be used in intramedullary interlocking nail surgery or arthroscopic


surgery.
With the perfect shape of ergonomic design,whole unit is autoclavable,motor is
imported,low noise,high speed,high proper alignment,long service life. The machine is
warranty for 2 years.

Specification:

Output power ≥90w


Speed(r.p.m) 0-630(Default)/0-1000(Customized)
Oscillations (osc/min) /
Torque(Nm) 3.6
Operation(V) voltage 14.4
Sterilization 155°C
Swings (°) /
Noise(db) ≤40

Hand Piece:
Main Accesories:
Basic Stpes of Sterilization, Cleaning and Maintenance
Standard Configuration:

1. One handpiece

2. One battery

3. One charger

4. One Aseptic battery transfer ring

5. One Operating manual

6. One Guarantee Card

Warranty:

The handpiece guarantees for 2 years, the battery and other fast consumption items
guarantee for 3 months.

Advantages:

1.Our whole power tool can be autoclavable.

2.We can autoclavable for 135 °C (Improved type ≤ 155 °C ),with 1.6Mpa,in this way the bacilli
and virus which can not killed by the suffocating will be killed.

3.We use environment friendly nickel-metal hydride battery.

4.The machine has very low noise.

5.Our products has 2 years warranty period.

Notes:

1.Sterilize temperature ≤ 135 °C (Improved type ≤ 155 °C ),if the temperature is over 135 ° C
,the motor will be damaged.

2.Normal bone drill can only hold drill bits less than 6mm,acetabulum reaming drill with big
torque,rpm is around 300,canulate drill is used with nail or K wire ,rpm is around 600.
3.The battery need to be get out of the pwer tool after surgery.Otherwise the small automatic
discharge of the electric will make the life of the battery short.

4.The battery cannot be sterilized ,it is not autoclavable.

5.The cranial bur must be washed right after the surgery by purger in order to aviod the blood
stick in the bur,then we should make it dry.

6.The battery space in the handpiece of the tool should not have any water,after sterilization.

7.The cranial bur blade is made of medical stainless steel,in order to avoid broken,so it is
flexible and not very hard,it is easy to be attrite,we suggest each blade only use for 1 surgery.

@ COPYRIGHT

@ COPYRIGHT 2014-2016, ALL RIGHTS RESERVED Shanghai Bojin Medical