Brochure
CloudEngine S12700E Series Switches
Huawei CloudEngine S12700E series switches are new core switches designed for next-
generation high-quality campus networks. These purpose-built switches help create a campus
network that improves user experiences, reduces operating costs, and delivers unmatched
security and trustworthiness for a fully connected, wireless era.
Product Overview
Huawei CloudEngine S12700E series switches ("CloudEngine S12700E") are flagship core switches in Huawei's CloudCampus
Solution. By building an intelligent campus core, these feature-rich switches help customers head towards a service experience-
centric campus network that is intelligent and simplified.
CloudEngine S12700E stands out with massive capacity expansion and flexible service upgrade capabilities to protect customer
investments and facilitate their long-term network evolution. Built on Huawei's high-performance Solar series chipsets,
CloudEngine S12700E delivers up to 4.8 Tbps of single-slot bandwidth. CloudEngine S12700E also offers a broad range of line
cards, including 100GE, 40GE, 10GE, and GE line cards, and provides up to 288 x 100GE ports, the unmatched port density in
the industry. These give customers flexible choices to meet their capacity expansion and upgrade needs.
By integrating large-capacity WLAN AC capabilities, a single CloudEngine S12700E can manage up to 10,240 WLAN APs. This
capability, combined with free mobility functionality, achieves fully converged wired and wireless networks and policies, greatly
simplifying network management with users and services at the core.
With a holistic set of reliability, security, and trusted features, CloudEngine S12700E is ideal for building a reliable, secure, and
trustworthy campus core. By using a next-generation cell switching architecture, CloudEngine S12700E ensures non-blocking
service data forwarding on core nodes and guarantees service quality in high-concurrency, large-capacity, and high-load
environments.
Models and Appearances
CloudEngine S12700E is available in three models: S12700E-4, S12700E-8, and S12700E-12.
CloudEngine S12700E Series Switches 1
CloudEngine S12700E-4 CloudEngine S12700E-8 CloudEngine S12700E-12
Features and Highlights
Switch Highlights
Fully-programmable Architecture
Built on Solar series chipsets with a fully-programmable architecture, CloudEngine S12700E adapts to the changing
forwarding processes driven by protocol evolution and technology advances. It enables fast and flexible provisioning of new
services simply by upgrading software, without having to replace hardware, thereby protecting customers' investment. In
contrast, traditional ASIC chips use a fixed forwarding architecture and follow a fixed forwarding process; as a result, new
services cannot be provisioned until new hardware is developed to support the services, which may take 1 to 3 years.
Wired and Wireless Convergence
By integrating WLAN AC capabilities, CloudEngine S12700E eliminates the need to purchase additional WLAN AC
hardware. Each CloudEngine S12700E can manage up to 10,240 APs. With up to 4 Tbps WLAN AC forwarding capacity,
CloudEngine S12700E avoids the performance bottleneck on independent WLAN AC devices. As such, organizations are well
poised to cope with challenges in the high-speed wireless era.
CloudEngine S12700E supports the unified user management function that authenticates both wired and wireless users,
ensuring a consistent user experience no matter whether they are connected to the network through wired or wireless access
devices. CloudEngine S12700E supports various authentication methods, including PPPoE, 802.1X, MAC address, and Portal
authentication, and is capable of managing users based on user groups, domains, and time ranges. These functions intuitively
control user and service management and enable the transformation from data switching-centered management to service
experience-centered management.
Refined Network Management
Packet Conservation Algorithm for Internet (iPCA) changes the traditional method that uses simulated traffic for fault
location. iPCA technology monitors network quality for any service flow at any network node, at any time, and without extra
costs. It can quickly detect intermittent service interruptions and accurately identify faulty ports. This cutting-edge fault detection
technology turns "extensive management" into "fine granular management."
Super Virtual Fabric 2.0 (SVF 2.0) technology can not only virtualize fixed-configuration switches into modular switch line
cards but also virtualize APs as switch ports. With this virtualization technology, a physical network with core/aggregation
switches, access switches, and APs can be virtualized into a "super switch", simplifying network management.
CloudEngine S12700E series manages access switches in a similar way a WLAN AC manages APs, saving the trouble of
laborious configuration on access switches. It manages access switches and APs uniformly, allowing them to connect to the
network with zero configuration.
CloudEngine S12700E Series Switches 2
System Openness Capability
CloudEngine S12700E supports NETCONF/YANG through which users can perform automated configuration.
CloudEngine S12700E supports the Open Programmability System (OPS), an open programmable system based on the
Python language. IT administrators can program the O&M functions of CloudEngine S12700E through Python scripts to quickly
innovate functions and implement intelligent O&M.
Secure and Trustworthy System
Digital signatures of codes are used to identify software sources and the real identities of software developers to ensure
that code is not tampered with after being signed. To protect software, CloudEngine S12700E uses two levels of signature
mechanisms: inner signature and outer signature.
CloudEngine S12700E supports secure boot based on the hardware trust root. Starting from the trusted hardware anchor,
the software code to be loaded is checked level by level. This approach ensures that the MPUs, line cards, and SFUs are not
intruded since the boot phase.
The chipsets provide a secure Random Number Generator (RNG) module certified by NIST SP 800-90A and NIST SP 800-
90B to generate true secure random numbers for system running, thereby ensuring secure and trustworthy encryption.
Network-Level Reliability
CloudEngine S12700E uses link detection technologies such as hardware Eth-OAM and BFD, and adopts
standard/standards-compatible link switching technologies like G.8032 and Smart Ethernet Protection (SEP). These
technologies achieve end-to-end 50 ms hardware-level switchover and help build highly responsive campus network that
provides highly reliable services.
CloudEngine S12700E supports High-speed Self Recovery (HSR) technology that implements end-to-end IP MPLS
transmission network protection switchover within 50 ms, improving network reliability.
Easy Operation
CloudEngine S12700E supports EasyDeploy that implements plug-and-play for newly deployed devices and centrally manages
all devices running on the network. Typical Easy Deploy functions include the following:
Implementing Zero Touch Provisioning (ZTP) to automatically load the boot files such as version files, configuration files,
and patches
Upgrading network devices and delivering configurations in batches
Quickly replacing old devices with new ones that are plug-and-play without configuration
Intelligent Diagnosis
CloudEngine S12700E supports Open Intelligent Diagnosis System (OIDS). By integrating the device health monitoring
and fault diagnosis functions – that are typically deployed on a Network Management System (NMS) – into the switch
software, OIDS implements intelligent diagnosis on a single switch.
After OIDS is deployed on a switch, the switch periodically collects and records the running information and automatically
determines whether a fault occurs. If a fault occurs, the switch automatically locates the fault or helps locate the fault. All these
merits increase fault locating efficiency of O&M staff while improving device maintainability.
Solution Benifits
Simplified Management
Deployment automation: CloudEngine S12700E supports VXLAN and BGP-EVPN, and builds a Unified Virtual Fabric
(UVF) to automate deployment of up to 512 Virtual Networks (VNs). In this way, multiple service networks or tenant networks
can be deployed and isolated from each other on the same physical network, truly achieving one network for multiple purposes.
Policy automation: CloudEngine S12700E automates deployment of wired and wireless user policies on the entire network
and implements refined management and control based on SDN to achieve free mobility.
Intelligent O&M
CloudEngine S12700E provides telemetry technology to collect device data in real time and send the data to the
CampusInsight (a campus network analysis component of Huawei iMaster NCE). The CampusInsight then analyzes network
data based on the intelligent fault identification algorithm, accurately displays the real-time network status, effectively
CloudEngine S12700E Series Switches 3
demarcates and locates faults in a timely manner, and identifies network problems that affect user experience, accurately
guaranteeing user experiences.
CloudEngine S12700E supports a variety of intelligent O&M features for audio and video services, including the enhanced
Media Delivery Index (eMDI). With the eMDI function, the switch can function as a monitored node to periodically conduct
statistics and report audio and video service indicators to the CampusInsight. In this way, the CampusInsight can quickly
demarcate audio and video service quality faults based on the results of multiple monitored nodes.
Big Data Security Collaboration
CloudEngine S12700E uses NetStream to collect campus network data and then reports such data to the Analysis system.
The purposes of doing so are to detect network security threats, display the security posture across the entire network, and
enable automated or manual response to security threats. The system then delivers the security policies to the Agile Controller
which, subsequently, delivers such policies to the switch that will handle security events accordingly. All these ensure campus
network security.
Licensing
CloudEngine S12700E supports both the traditional feature-based licensing mode and the latest Huawei IDN One Software (N1
mode for short) licensing mode. The N1 mode is ideal for deploying Huawei CloudCampus Solution in the on-premises scenario,
as it greatly enhances the customer experiences in purchasing and upgrading software services with simplicity.
Software Package Features in N1 Mode
Switch Functions N1 Basic N1 Foundation N1 Advanced
Software Software Package Software
Package
Basic network functions: √ √ √
Layer 2 functions, IPv4, IPv6, MPLS, SVF, and others
Basic network automation based on the Agile × √ √
Controller:
Basic automation: Plug-and-play, SSID, and AP
group management
Basic monitoring: Application visualization
NE management: Image and topology management
and discovery
WLAN enhancement: Roaming and optimization for
up to 128 APs
Advanced network automation and intelligent O&M: × × √
VXLAN, user access authentication, free mobility, and
CampusInsight basic functions
Note: Only V200R019C00 and later versions can support N1 mode
Product Specifications
Functions and Features
Category Service Features CloudEngine CloudEngine CloudEngine
S12700E-4 S12700E-8 S12700E-12
User Unified user management √ √ √
management
PPPoE, 802.1X, MAC, and Portal √ √ √
CloudEngine S12700E Series Switches 4
Category Service Features CloudEngine CloudEngine CloudEngine
S12700E-4 S12700E-8 S12700E-12
authentication
Traffic- and duration-based accounting √ √ √
User authorization based on user groups, √ √ √
domains, and time ranges
MAC address Number of MAC address entries 512K(MAX) 512K(MAX) 512K(MAX)
Automatic MAC address learning and aging √ √ √
Static, dynamic, and blackhole MAC address √ √ √
entries
Source MAC address filtering √ √ √
MAC address learning limiting based on ports √ √ √
and VLANs
VLAN 4K VLANs √ √ √
Access, trunk, and hybrid interface types; √ √ √
auto-negotiation of LNP link types
Default VLAN √ √ √
VLAN switching √ √ √
QinQ and enhanced selective QinQ √ √ √
Dynamic VLAN assignment based on MAC √ √ √
addresses
ARP Maximum number of ARP entries 256K(MAX) 256K(MAX) 256K(MAX)
ARP Snooping √ √ √
IP routing Maximum number of IPv4 routing entries 512K(MAX) 512K(MAX) 512K(MAX)
IPv4 dynamic routing protocols such as RIP, √ √ √
OSPF, IS-IS, and BGP
IPv6 dynamic routing protocols such as RIPng, √ √ √
OSPFv3, ISISv6, and BGP4+
Multicast Maximum number of multicast routing entries 64K(MAX) 64K(MAX) 64K(MAX)
IGMPv1/v2/v3 and IGMP v1/v2/v3 Snooping √ √ √
PIM-DM, PIM-SM, and PIM-SSM √ √ √
MSDP and MBGP √ √ √
Fast-leave mechanism √ √ √
Multicast traffic control √ √ √
Multicast querier √ √ √
Multicast protocol packet suppression √ √ √
Multicast Call Admission Control (CAC) √ √ √
Multicast ACL √ √ √
MPLS Basic MPLS functions √ √ √
CloudEngine S12700E Series Switches 5
Category Service Features CloudEngine CloudEngine CloudEngine
S12700E-4 S12700E-8 S12700E-12
MPLS OAM √ √ √
MPLS TE √ √ √
MPLS VPN/VLL/VPLS √ √ √
VXLAN VXLAN distributed gateway and centralized √ √ √
gateway
BGP-EVPN √ √ √
Configures VXLANs through NETCONF √ √ √
QoS Number of ACL rules 6K(MAX) 6K(MAX) 6K(MAX)
Traffic classification based on Layer 2 √ √ √
headers, Layer 3 protocols, Layer 4 protocols,
and 802.1p priority
Actions such as ACL, Committed Access Rate √ √ √
(CAR), re-marking, and scheduling
Queuing algorithms, such as PQ, WRR, DRR, √ √ √
PQ+WRR, and PQ+DRR
Congestion avoidance mechanisms such as √ √ √
WRED and tail drop
HQoS √ √ √
Traffic shaping √ √ √
iPCA Marks the real service packets to obtain real- √ √ √
time count of dropped packets and packet loss
ratio
Counts the number of dropped packets and √ √ √
packet loss ratio on devices and L2/L3
networks
SVF 2.0 Up to 10K clients (access switches and APs) √ √ √
virtualized into a single device
Two layers of ASs allowed in an SVF system √ √ √
Third-party devices allowed between SVF √ √ √
parent and clients
Ring network STP (IEEE 802.1d), RSTP (IEEE 802.1w), and √ √ √
protection MSTP (IEEE 802.1s).
SEP √ √ √
BPDU protection, root protection, and loop √ √ √
protection
BPDU tunnel √ √ √
G.8032 Ethernet Ring Protection Switching √ √ √
(ERPS)
Reliability Link Aggregation Control Protocol (LACP) and √ √ √
E-Trunk
CloudEngine S12700E Series Switches 6
Category Service Features CloudEngine CloudEngine CloudEngine
S12700E-4 S12700E-8 S12700E-12
Virtual Router Redundancy Protocol (VRRP) √ √ √
and Bidirectional Forwarding Detection (BFD)
for VRRP
BFD for BGP/IS-IS/OSPF/static routes √ √ √
Non-Stop Forwarding (NSF) and Graceful √ √ √
Restart (GR) for BGP/IS-IS/OSPF/LDP
TE Fast ReRoute (FRR) and IP FRR √ √ √
Eth-OAM 802.3ah and 802.1ag (hardware- √ √ √
based)
High-speed Self Recovery (HSR) √ √ √
ITU-Y.1731 √ √ √
Device Link Detection Protocol (DLDP) √ √ √
Smart Link √ √ √
Monitor Link √ √ √
Configuration Easy Operation √ √ √
and
maintenance Terminal access services such as console port √ √ √
login, Telnet, and SSH
Network management protocols, such as √ √ √
SNMPv1/v2/v3
File uploading and downloading through FTP √ √ √
and TFTP
BootROM upgrade and remote in-service √ √ √
upgrade
Hot patches √ √ √
User operation logs √ √ √
Open Programmability System (OPS) √ √ √
Streaming Telemetry √ √ √
eMDI √ √ √
Security and MAC address, Portal, 802.1X, and DHCP √ √ √
management snooping-triggered authentication
MACsec √ √ √
NAC √ √ √
RADIUS and HWTACACS authentication for √ √ √
login users
Command line authority control based on user √ √ √
levels, preventing unauthorized users from
using command configurations
Defense against DoS attacks, Transmission √ √ √
Control Protocol (TCP) SYN Flood attacks,
User Datagram Protocol (UDP) Flood attacks,
CloudEngine S12700E Series Switches 7
Category Service Features CloudEngine CloudEngine CloudEngine
S12700E-4 S12700E-8 S12700E-12
broadcast storms, and heavy traffic attacks
1K CPU hardware queues to implement √ √ √
hierarchical scheduling and protection for
protocol packets on the control plane
Remote Network Monitoring (RMON) √ √ √
Secure boot (need to use MPU that supports √ √ √
secure boot)
Big data security collaboration √ √ √
Wireless Mesh networking √ √ √
management
(integrated N+N cold backup for devices with integrated √ √ √
WLAN AC): WLAN AC functionality
Basic WLAN Hot backup for devices with integrated WLAN √ √ √
services AC functionality in cluster mode
WLAN terminal location √ √ √
Locating of interference sources √ √ √
Spectrum analysis function √ √ √
2.4G & 5G load balancing √ √ √
5G-prior access √ √ √
Wireless Total number of managed APs 10K 10K 10K
management
(integrated An IPv4 network between an AP and a WLAN √ √ √
WLAN AC): AC
AP AP blacklist √ √ √
management
AP whitelist √ √ √
Sets the AP access control mode √ √ √
AP configuration and management √ √ √
AP energy saving √ √ √
AP LLDP topology awareness √ √ √
Adjustable priority of traffic on wired interfaces √ √ √
of APs
Rate limiting on wired interfaces of APs √ √ √
Wireless User roaming within a WLAN AC √ √ √
management
(integrated AP-based user location √ √ √
WLAN AC):
User roaming between WLAN ACs √ √ √
Wireless user
management 802.1X authentication √ √ √
Portal authentication √ √ √
MAC address authentication √ √ √
Wireless Direct data forwarding on L2/L3 networks √ √ √
CloudEngine S12700E Series Switches 8
Category Service Features CloudEngine CloudEngine CloudEngine
S12700E-4 S12700E-8 S12700E-12
management Tunnel-based data forwarding on L2/L3 √ √ √
(integrated networks
WLAN AC):
CAPWAP Dual-link load balancing for CAPWAP tunnels √ √ √
CAPWAP tunnel encryption √ √ √
Wireless 802.11a/b/g/n √ √ √
management
(integrated 802.11ac wave1/wave2 √ √ √
WLAN AC):
802.11ax √ √ √
RF
management Sets RF interference monitoring and √ √ √
avoidance
Detects co-channel interference, adjacent √ √ √
interference, and interference from other
devices and STAs
Automatically selects channels and power √ √ √
when APs go online
Dynamic power and channel optimization √ √ √
Wireless Mapping from wireless-side priority to wired- √ √ √
management side priority
(integrated
WLAN AC): Mapping from wireless-side priority to √ √ √
CAPWAP channel priority
WLAN QoS
Rate limiting of upstream and downstream √ √ √
traffic on the air interface based on the VAP
Rate limiting of upstream and downstream √ √ √
traffic on the air interface based on users
SSID-based CAR √ √ √
CAR for WLAN users √ √ √
Interoperability Interoperable with VBST (compatible with √ √ √
PVST/PVST+/RPVST)
Interoperable with LNP (similar to DTP) √ √ √
Interoperable with VCMP (similar to VTP) √ √ √
Hardware Specifications
Item CloudEngine S12700E-4 CloudEngine S12700E-8 CloudEngine S12700E-12
Switching capacity 19.2 Tbps 38.4 Tbps 57.6Tbps
Forwarding 14,400 Mpps 28,800 Mpps 43,200 Mpps
performance
MPU slots 2 2 2
SFU slots 2 4 4
LPU slots 4 8 12
Fan trays 2 4 5
CloudEngine S12700E Series Switches 9
Item CloudEngine S12700E-4 CloudEngine S12700E-8 CloudEngine S12700E-12
Power 4 6 6
Buffering capacity Up to 200 ms data buffering Up to 200 ms data buffering Up to 200 ms data buffering per port
per port per port
Redundancy MPU, SFU, power module, MPU, SFU, power module, MPU, SFU, power module, and fan
design and fan module and fan module module
Virtualization CSS service port clustering CSS service port clustering CSS service port clustering
Dimensions (H x 441.7*442*517.4,10U 663.95*442*517.4, 15U 841.75*442*517.4, 19U
W x D)
Weight 24.5kg/66kg 42.5kg/114kg 71.8kg/184kg
(empty/fully Note Note Note
configured)
Empty configuration Empty configuration Empty configuration indicates that
indicates that the switch indicates that the switch the switch has no line card, MPU,
has no line card, MPU, or has no line card, MPU, or or power supply installed. Filler
power supply installed. power supply installed. panels are used, instead.
Filler panels are used, Filler panels are used, Full configuration indicates that
instead. instead. the switch is fully configured with
Full configuration Full configuration indicates MPUs, SFUs, line cards, and
indicates that the switch that the switch is fully power supplies. Their maximum
is fully configured with configured with MPUs, weights are used during
MPUs, SFUs, line cards, SFUs, line cards, and calculation.
and power supplies. power supplies. Their
Their maximum weights maximum weights are used
are used during during calculation.
calculation.
Operating voltage DC:–48V~–60V
AC:90V~290V
Maximum power 3344W 6950W 8981W
consumption
Operating –60 m to +1800 m: 0°C to 45°C
temperature 1800 m to 4000 m: The maximum operating temperature decreases by 1°C each time the altitude
increases by 220 m.
4000 m: 0°C to 35°C
Relative humidity 5% to 95% (non-condensing)
Heat dissipation Left-to-rear airflow, air-cooled heat dissipation, and intelligent fan speed adjustment
mode
Networking and Applications
In an Enterprise Campus Network
CloudEngine S12700E can be deployed at the core layer of an enterprise campus network. With the integrated WLAN AC
functionality, CloudEngine S12700E enables customers to build wireless networks at lowered costs without additional WLAN AC
hardware. By providing up to 4 Tbps WLAN AC forwarding capacity, CloudEngine S12700E eliminates the performance
bottleneck on independent WLAN ACs and gets customers ready for the Wi-Fi 6 era. CloudEngine S12700E truly achieves
wired and wireless convergence and delivers consistent user experiences through unified device, user, and service
management.
CloudEngine S12700E Series Switches 10
In a School Campus Network
CloudEngine S12700E can be deployed at the core layer of a school campus network. With unified user management
functionality, CloudEngine S12700E reduces network construction costs by removing the need to purchase new BRAS
hardware. Its compelling HQoS feature delivers granular user and service management. CloudEngine S12700E stands out with
wired and wireless convergence and delivers consistent user experiences through unified device, user, and service
management.
In a Bearer Network for Video Conferencing, Desktop Cloud, and Video Surveillance
Applications
CloudEngine S12700E can be deployed on a bearer network for video conferencing, desktop cloud, and video surveillance
applications. Designed with a large buffering capacity, CloudEngine S12700E prevents packet loss upon traffic bursts, delivering
high-quality, smooth video streams. Million-level table entries provided by CloudEngine S12700E allow access from a large
number of terminals and deliver unmatched resilience needed for IPv6 and IoT evolution. Employing end-to-end hardware
reliability and iPCA technologies, CloudEngine S12700E offers a highly reliable, high-quality, scalable video conferencing and
surveillance solution.
On a MAN
CloudEngine S12700E can be deployed at the core or aggregation layer of the broadcasting and education MAN. CloudEngine
S12700E supports comprehensive L2/L3 MPLS VPN functions and provides a highly reliable, secure, and scalable MAN bearer
solution.
In an Enterprise Data Center
CloudEngine S12700E can be deployed at the core or aggregation layer of an enterprise data center. Coming with high-
bandwidth high-density cards, CloudEngine S12700E delivers massive data throughput needed for core and aggregation nodes
in the data center. As such, customers can leverage CloudEngine S12700E to build a data center network with high
performance, high reliability, and low latency.
Ordering Information
CloudEngine S12700E Basic Configuration
LE2BN66ED000 N66E DC assembly cabinet (eight 60A outputs, maximum 2200W, 600 × 600 × 2200 mm)
LE2BN66EA000 N66E AC assembly cabinet (four 16 A outputs, a maximum of 2500W, 600 × 600 × 2200 mm)
ET1BS12704E0 S12700E-4 assembly chassis
ET1BS12708E0 S12700E-8 assembly chassis
ET1BS12712E1 S12700E-12 assembly chassis
FAN-770A-B Fan box (-5degC–55degC, 48V, 400W, 2, indoors, VA)
Main Processing Unit
LST7MPUE0000 S12700E Main Processing Unit E
Monitoring Board
EH1D200CMU00 Centralized Monitoring Unit
CloudEngine S12700E Series Switches 11
Switch Fabric Unit
LST7SFUEX100 S12700E Switch Fabric Unit E(X1)
LST7SFUHX100 S12700E Switch Fabric Unit H(X1)
LST7SFUMX100 S12700E Switch Fabric Unit M(X1)
100G Ethernet optical interface board
LST7C06HX6E0 6-port 100GE QSFP28 interface card (X6E,QSFP28)
LST7C06HX6S0 6-port 100GE QSFP28 interface card (X6S,QSFP28)
LST7C24HX6E0 24-port 100GE QSFP28 interface card (X6E,QSFP28)
10GE optical interface card
LST7X48SX6E0 48-port 10GE SFP+ interface card (X6E,SFP+)
LST7X48SX6S0 48-port 10GE SFP+ interface card (X6S,SFP+)
10GE/1000M Ethernet optical interface card
LST7X24BX6E0 24-port 10GE SFP+ interface and 24-port GE SFP interface card (X6E,SFP+)
LST7X24BX6S0 24-port 10GE SFP+ interface and 24-port GE SFP interface card (X6S,SFP+)
Gigabit Ethernet optical interface board
LST7G48SX6E0 48-port GE SFP interface card (X6E,SFP)
LST7G48SX6S0 48-port GE SFP interface card (X6S,SFP)
Gigabit Ethernet electrical interface board
LST7G48TX5E1 48-port 10/100/1000BASE-T interface card (X5E,RJ45)
LST7G48TX5S1 48-port 10/100/1000BASE-T Interface Card (X5S,RJ45)
Power supply
W2PSD2200 2200W DC power module
PAC3KS54-CE 3000W AC power module (black)
License
L-1AP-S127E S127E Series, Wireless Access Controller AP Resource License-1AP
CloudEngine S12700E Series Switches 12
License
N1-S127E-F-Lic N1-CloudCampus,Foundation,S127E Series,Per Device
N1-S127E-F-SnS1Y N1-CloudCampus,Foundation,S127E Series,SnS,Per Device,1Year
N1-S127E-A-Lic N1-CloudCampus,Advanced,S127E Series,Per Device
N1-S127E-A-SnS1Y N1-CloudCampus,Advanced,S127E Series,SnS,Per Device,1Year
N1-S127E-FToA-Lic N1-Upgrade-Foundation to Advanced,S127E,Per Device
N1-S127E-FToA-
N1-Upgrade-Foundation to Advanced,S127E,SnS,Per Device,1Year
SnS1Y
N1-S127E-M-Lic N1-CloudCampus,Device Management,S127E Series,Per Device
N1-S127E-M-SnS1Y N1-CloudCampus,Device Management,S127E Series,,SnS,Per Device,1Year
N1-AC1.0-AM-15-Lic N1-CloudCampus,Access Management-AC1.0,15 Terminals
N1-AC1.0-AM-15-
N1-CloudCampus,Access Management-AC1.0,15 Terminals,SnS,1Year
SnS1Y
CI-X7MSwitch-U CampusInsight-Upgrade-Foundation to Advanced, X7 Series Modular Switch, Per Device
CI-X7MSwitch-U- CampusInsight-Upgrade-Foundation to Advanced, X7 Series Modular Switch, SnS, Per Device, 1
SnS1Y Year
More Information
For more information about Huawei Campus Switches, visit http://e.huawei.com or contact us in the following ways:
Global service hotline: http://e.huawei.com/en/service-hotline
Logging in to the Huawei Enterprise technical support website: http://support.huawei.com/enterprise/
Sending an email to the customer service mailbox:
[email protected]Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and
Huawei Technologies Co., Ltd.
recommendations in this document are provided "AS IS" without warranties, guarantees or representations of
any kind, either express or implied. Address:Huawei Industrial Base Bantian,
Longgang Shenzhen 518129 People's
The information in this document is subject to change without notice. Every effort has been made in the
Republic of China
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied. Website:e.huawei.com
CloudEngine S12700E Series Switches 13