2016 AZZ Full Line Product Catalog PDF
2016 AZZ Full Line Product Catalog PDF
Driving winds, extreme temperatures, volatile chemicals AZZ's LED designs provide the unique benefit of field-
and explosive gasses–needless to say, the hazardous and replaceable circuit boards and drivers. With a high
severe environments of offshore rigs, chemical plants, degree of serviceability, individual components can be
wastewater treatment facilities and food processing replaced as needed, maximizing service life while
centers are no place for ordinary lighting. Fortunately, as lowering total cost of ownership.
a leader in severe duty lighting components, AZZ
Our application-proven line of traditional products
pioneers rugged illumination solutions built to withstand
maintain the heavy-duty designs and rugged materials
the harshest conditions.
that first established AZZ as an industry leader.
Established in 1938 to support the demanding
requirements of the drilling industry, Rig-A-Lite quickly
earned a reputation for quality, dependability and
performance. As AZZ, our focus has expanded to
providing long-lasting, purpose-built products to a vast
array of industries, but our steadfast commitment
remains to provide knowledgeable and responsive
service, product accessibility and rapid order fulfillment.
713.943.0340 | azz.com/rigalite
MAR2 LED
Linear LED Lighting for Hazardous Locations
Key Features:
1 Heavy-duty .094” thick extruded housing
2 Permanent safety cable attachment points
3 Two ¾” NPT conduit hubs
2 4
4 360º mounting flexibility
5 Field-replaceable LED circuit boards and drivers with quick 7 3
disconnects
6 Toolless entry via twist-lock latches
7 Watershed design
5
MAR2 07 - L2 - 4 - U - XX
1 2 3 4 5 6
1Mounting Hardware not included. Please see accessories for mounting selec-
tions.
2Specify voltage when option F is needed. When option F is selected, one fuse
is provided for 120 and 277V. Two fuses are provided for 220-240V. Fuse
option not available for marine listed fixtures, or for fixtures listed for use in
Canada.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
MAR2 LED
Linear LED Lighting for Hazardous Locations
Certification Guide
Supply Wire
Lumen Class I, Div. 2,
Total Suitable
Model Length Wattage Operating Voltage per CRI CCT Ambient Temperature Group Hub Size
Lumens Temperature,
Watt A, B, C & D
°C
MAR206L22U 2 ft 56W 120V - 277V 50/60 Hz 5476 98 85 4062 -20°C < Tamb < 55°C T6 90°C 3/4 in. NPT
MAR207L24U 4 ft 74W 120V - 277V 50/60 Hz 7660 103 82 4071 -20°C < Tamb < 55°C T6 90°C 3/4 in. NPT
MAR207L24U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance rcc 80 50 10 Deg. Parl. 22.5 45 67.5 Norm
% Wall Reflectance rw 50 30 10 50 30 10 50 30 10 0 2760 2760 2760 2760 2760
Room Cavity Ratio
RCR Effective Floor Cavity Reflectance 20% 15 2680 2666 2675 2676 2669
0 119 119 119 111 111 111 102 102 102 25 2513 2495 2516 2522 2519
1 106 102 98 99 96 94 92 90 88 35 2261 2248 2286 2295 2285
2 93 86 81 87 82 78 81 78 75 45 1925 1921 1960 1938 1921
3 82 74 68 77 71 66 72 67 64 55 1495 1516 1511 1459 1444
4 72 64 57 69 62 56 64 59 55 65 978 1004 953 941 928
5 65 56 49 61 54 49 58 52 48 75 409 399 344 17 15
6 58 49 43 55 48 42 52 46 42 85 34 5 4 4 4
7 53 44 38 50 43 38 48 42 37 90 0 0 0 0 0
8 48 40 34 46 39 33 44 38 33
9 44 36 30 42 35 30 40 34 30
10 41 33 27 39 32 27 37 31 27
MAR206L22U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance rcc 80 50 10 Deg. Parl. 22.5 45 67.5 Norm
% Wall Reflectance rw 50 30 10 50 30 10 50 30 10 0 2068 2068 2068 2068 2068
Room Cavity Ratio
RCR Effective Floor Cavity Reflectance 20% 15 1999 1996 1995 1998 2002
0 119 119 119 111 111 111 102 102 102 25 1962 1834 1867 1869 1876
1 106 102 99 99 97 94 92 90 89 35 1661 1666 1673 1669 1669
2 93 87 82 88 83 79 82 78 75 45 1396 1405 1407 1384 1379
3 82 75 69 78 72 67 73 68 65 55 1068 1087 1063 1052 1051
4 73 65 58 69 66 57 65 60 56 65 677 691 682 362 348
5 65 57 50 62 55 50 59 53 49 75 267 270 142 127 29
6 59 50 44 56 49 44 53 47 43 85 15 3 4 4 4
7 53 45 39 51 44 39 48 43 38 90 0 0 0 0 0
8 49 40 35 47 40 34 44 38 34
9 45 37 31 43 36 31 41 35 31
10 41 34 28 40 33 28 38 32 28
LED
MAR2 LED
Linear LED Lighting for Hazardous Locations
Accessories
713.943.0340 | azz.com/rigalite
MHD2 LED
Non-Metallic Heavy Duty LED Luminaire for Hazardous Locations
Key Features:
1 Heavy-duty 3/16” thick housing, reinforced to 3/8” at hub openings
2 Impact resistant 1/8” thick lens with reinforced corners
3 Convenient component assembly-tray held captive by two (2) nylon 5
coated stainless steel cables
4 Toolless, cage-clamp terminal block
5 Two ¾” NPT conduit hubs reinforced with 1/16” grounding plate and
locknuts 1
6 Field replaceable LED circuit boards and drivers with quick
3
disconnects
7 Toolless entry via over-the-center cam latches
7
4
6
MHD2 07-L2- 4 -U-XX
1 2 3 4 5 6
1 BASIC LUMINAIRE
MHD2 Non-Metallic LED
5 VOLTAGE/FREQUENCY
U = 120 - 277V 50/60 HZ
Class I, Division 2, Groups A, B, C and D A = 120V 60HZ1
Class II, Division 2 Groups F & G B = 220 - 240V 50/60HZ1
Class III C = 277V 60Hz1
UL 844 Hazardous Locations
UL 1598A Marine Outside Type
UL 8750 LED Safety
CSA C22.2 #137; C22.2 #213
6 OPTIONS1
P = Polycarbonate Lens
ETL Listed FB = Fuse Block1
Tested to LM 79 & LM 80 TW = Thru Wire
55° C Ambient Temperature Cable Installations Only
IP66 PM = Pendant Mount
SP = Increased Surge Protection, 10kV
2 LAMP CURRENT/LAMP WATTAGE
06 = 56 Watt
30 = 3000K CCT
35 = 3500K CCT
07 = 74 Watt 50 = 5000K CCT
3 LAMP TYPE
L2 = LED (4000K CCT)
4 NOMINAL FIXTURE LENGTH 1 Specify voltage when option FB is needed. When option FB is
selected, one fuse is provided for 120 and 277V. Two fuses are
4 = Four Foot
provided for 220-240V. Fuse option not available for marine listed
fixtures, or for fixtures listed for use in Canada.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
Options
LED
MHD2
Non-Metallic Heavy Duty LED Luminaire for Hazardous Locations
MHD207L24U
CandlepowerDistribution Coefficients of Utilization Photometric Data
Deg. 0 15 30 45 60 75 90 Effective Floor Cavity Reflectance 0.20
0 2556 2556 2556 2556 2556 2556 2556 % Effective
Ceiling
5 2535 2536 2543 2547 2550 2547 2553 Cavity 80 70 50 30 10 0
10 2497 2500 2510 2514 2514 2516 1530 Reflectance rcc
15 2433 2439 2457 2459 2454 2451 2460 % Wall
Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20 2349 2355 2364 2374 2367 2358 2361 Room Cavity Ratio
RCR Effective Floor Cavity Reflectance 20%
25 2242 2254 2262 2255 2259 2245 2246
30 2115 2122 2131 2128 2117 2105 2105 0 118 118 118 118 115 115 115 115 109 109 109 103 103 103 98 98 98 96
35 1971 1979 1980 1973 1961 1964 1973 1 107 102 97 93 104 99 95 91 94 91 88 90 87 84 85 83 81 79
40 1807 1810 1812 1796 1817 1836 1840 2 97 88 81 75 94 86 79 74 82 76 72 78 73 69 74 70 67 65
45 1623 1626 1623 1628 1642 1630 1627 3 88 77 69 62 85 75 68 61 72 65 60 68 63 58 65 61 57 54
50 1424 1426 1425 1437 1436 1468 1503 4 81 68 59 52 78 67 58 52 64 56 51 61 55 49 58 53 48 46
55 1215 1218 1232 1245 1363 1439 1451 5 74 61 52 45 72 60 51 45 57 49 44 54 48 43 52 47 42 40
60 1023 1030 1051 1160 1278 1315 1324 6 68 55 46 39 66 54 45 39 51 44 38 49 43 37 47 41 37 35
65 809 824 887 1059 1057 1081 1130 7 63 50 41 35 61 49 40 34 47 39 34 45 38 33 43 37 33 31
70 608 635 776 842 965 898 886 8 59 45 37 31 57 44 36 31 43 35 30 41 35 30 40 34 29 27
75 426 470 604 695 640 618 610 9 55 42 33 28 53 41 33 27 39 32 27 38 31 27 37 31 26 25
80 265 322 433 416 396 385 378 10 52 38 30 25 50 38 30 25 36 29 25 35 29 24 34 28 24 22
85 133 177 217 218 211 205 202
90 64 91 115 118 114 111 111
95 69 77 94 97 94 91 90
100 66 67 91 93 89 85 84
105 59 61 79 92 88 84 83
110 51 54 65 81 84 82 81
115 43 46 56 64 70 75 74
120 36 37 46 53 58 62 63
125 30 30 38 48 52 52 52
130 26 26 33 41 47 48 48
135 24 23 29 34 39 43 44
140 22 22 25 30 33 36 37
145 21 21 21 27 29 31 32
150 0 0 0 0 0 0 0
MHD206L24U
CandlepowerDistribution Coefficients of Utilization Photometric Data
Deg. 0 15 30 45 60 75 90 Effective Floor Cavity Reflectance 0.20
0 2060 2060 2060 2060 2060 2060 2060 % Effective
Ceiling
5 2038 2039 2045 2049 2052 2050 2055 Cavity 80 70 50 30 10 0
10 2010 2009 2019 2019 2021 2023 2039 Reflectance rcc
% Wall
15 1958 1962 1977 1977 1972 1971 1982 Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20 1885 1890 1899 1910 1901 1893 1897 Room Cavity Ratio
RCR Effective Floor Cavity Reflectance 20%
25 1803 1813 1817 1810 1815 1801 1803
30 1697 1703 1713 1708 1701 1693 1692 0 118 118 118 118 115 115 115 115 109 109 109 103 103 103 98 98 98 96
35 1583 1588 1587 1584 1574 1577 1586 1 107 102 97 93 104 99 95 91 94 91 88 90 87 84 85 83 81 79
40 1449 1451 1454 1442 1460 1475 1476 2 97 88 81 75 94 86 80 74 82 76 72 78 73 69 74 71 67 65
45 1302 1305 1302 1309 1316 1304 1299 3 88 77 69 62 85 75 68 61 72 65 60 69 63 58 65 61 57 54
50 1142 1143 1144 1150 1143 1162 1190 4 81 68 59 53 78 67 58 52 64 56 51 61 55 50 58 53 49 46
55 977 978 989 992 1085 1156 1164 5 74 61 52 45 72 60 51 45 57 50 44 55 48 43 52 47 42 40
60 820 824 839 922 1021 1057 1069 6 68 55 46 39 66 54 45 39 51 44 38 49 43 38 47 42 37 35
65 646 658 703 847 852 838 906 7 63 50 41 35 61 49 40 34 47 39 34 45 38 33 43 37 33 31
70 484 505 621 665 768 719 707 8 59 45 37 31 57 44 36 31 43 35 30 41 35 30 40 34 29 27
75 337 373 479 555 507 491 485 9 55 42 33 28 53 41 33 28 39 32 27 38 32 27 37 31 27 25
80 212 257 344 327 312 304 299 10 52 38 30 25 50 38 30 25 36 29 25 35 29 24 34 28 24 22
85 107 143 168 170 165 160 157
90 51 72 90 92 89 87 87
95 56 61 74 75 73 71 70
100 53 53 72 73 69 66 65
105 47 49 62 72 69 66 64
110 41 43 52 64 66 63 62
115 35 36 45 50 55 58 58
120 29 29 36 42 46 48 49
125 24 24 30 38 41 41 41
130 21 20 26 32 37 39 39
135 19 19 23 27 30 34 35
140 18 17 20 24 26 28 29
145 17 17 17 21 23 24 25
150 0 0 0 0 0 0 0
LED
MHD2
Non-Metallic Heavy Duty LED Luminaire for Hazardous Locations
Certification Guide
Supply Wire
Lumen Class I, Div. 2, Class II, Div. 2.
Total Suitable
Model Length Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group F & G
Lumens Temperature,
Watt A, B, C & D Class III
°C
MHD206L24U 4 ft 56W 120V - 277V 50/60 Hz 6235 109 84 4121 -20°C < Tamb < 55°C T5 T5 105°C
MHD207L24U 4 ft 74W 120V - 277V 50/60 Hz 7796 105 84 4142 -20°C < Tamb < 55°C T5 T5 105°C
A D
B
C
E
Accessories
713.943.0340 | azz.com/rigalite
MHDA
Linear LED Lighting for Hazardous Locations
Key Features:
1 Heavy-duty, continuous seam welded 1/16” thick housing
2 Impact resistant 1/8” thick lens with reinforced corners 5
3 Convenient component assembly-tray held captive by two nylon
coated stainless steel cables
4 Toolless, cage-clamp terminal block
4
1 3
5 Two ¾” NPT conduit hubs
6 Field replaceable LED circuit boards and drivers with quick
disconnects
7 Toolless entry via over-the-center cam latches
7
MHDA 07 - L2 - 4 - U - XX
1 2 3 4 5 6
1 BASIC LUMINAIRE
MHDA Aluminum LED
5 VOLTAGE/FREQUENCY
U = 120 - 277V 50/60 Hz
Class I, Division 2, Groups A, B, C and D A = 120V 60Hz1
Class II, Division 2 Groups F & G B = 220 - 240V 50/60Hz1
Class III C = 277V 60Hz1
UL 844 Hazardous Locations
UL 1598A Marine Outside Type
UL 8750 LED Safety 6 OPTIONS
CSA C22.2 #137; C22.2 #213 P = Polycarbonate Lens
Tested to LM 79 & LM 80 FB = Fuse Block1
55° C Ambient Temperature TW = Thru Wire
IP66 Cable Installations Only
PM = Pendant Mount
2 LAMP CURRENT/LAMP WATTAGE
07 = 74 Watt
SP = Increased Surge Protection, 10kV
30 = 3000K CCT
35 = 3500K CCT
50 = 5000K CCT
3 LAMP TYPE
L2 = LED (4000K CCT)
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
Options
LED
MHDA
Linear LED Lighting for Hazardous Locations
MHDA07L24U
Candlepower Distribution Coefficients of Utilization
Effective Floor Cavity Reflectance 0.20
0 15 30 45 60 75 90
% Effective
Ceiling
0 2553 2553 2553 2553 2553 2553 2553 Cavity 80 70 50 30 10 0
5 2523 2527 2536 2540 2544 2545 2551 Reflectance rcc
% Wall
10 2495 2496 2509 2510 2506 2508 2514 Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
15 2423 2432 2445 2455 2445 2438 2446 Room Cavity Ratio
RCR Effective Floor Cavity Reflectance 20%
20 2345 2354 2358 2358 2363 2351 2360
0 118 118 118 118 115 115 115 115 109 109 109 104 104 104 99 99 99 96
25 2235 2244 2256 2252 2249 2238 2240
30 2113 2120 2120 2124 2107 2109 2115
1 107 102 98 94 104 100 95 92 95 91 88 90 87 85 86 84 82 79
35 1964 1968 1978 1963 1981 2020 2033 2 97 89 81 76 94 86 80 74 82 77 72 78 74 70 75 71 68 65
40 1803 1807 1809 1815 1858 1845 1841 3 88 77 69 62 86 76 68 62 72 65 60 69 63 58 66 61 57 55
45 1619 1622 1624 1661 1649 1643 1668 4 81 68 59 53 78 67 58 52 64 57 51 61 55 50 58 53 49 46
50 1421 1424 1447 1457 1546 1621 1626
5 74 61 52 45 72 60 51 45 57 50 44 55 48 43 52 47 42 40
55 1213 1219 1250 1343 1447 1496 1497
60 1023 1035 1088 1262 1273 1302 1343
6 68 55 46 39 66 54 45 39 51 44 38 49 43 38 48 42 37 35
65 810 835 981 1051 1193 1138 1113 7 63 50 41 35 61 49 40 34 47 39 34 45 38 33 43 37 33 31
70 611 656 821 936 866 843 827 8 59 45 37 31 57 44 36 31 43 35 30 41 35 30 40 34 29 27
75 430 503 650 631 599 583 574 9 55 42 33 28 53 41 33 27 39 32 27 38 31 27 37 31 26 25
80 271 343 403 386 343 320 316 10 52 38 30 25 50 38 30 25 36 29 25 35 29 24 34 28 24 22
85 132 178 189 162 149 145 145
90 64 88 104 104 101 99 99
95 68 73 85 85 81 78 78
100 63 64 81 81 77 73 72
105 56 58 69 78 75 72 71
110
115
49
41
51
43
58
51
67
53
69
57
68
60
67
60
Photometric Data
120 34 35 43 46 47 50 51
125 29 29 36 43 43 42 43
130 25 25 31 38 41 41 41
135 23 23 27 32 37 40 40
140 22 21 24 29 31 34 35
145 21 20 21 26 28 30 31
150 0 0 0 0 0 0 0
LED
MHDA
Linear LED Lighting for Hazardous Locations
Certification Guide
Supply Wire
Lumen Class I, Div. 2, Class II, Div. 2.
Total Suitable
Model Length Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group F & G
Lumens Temperature,
Watt A, B, C & D Class III
°C
MHDA07L24U 4 ft 74W 120V - 277V 50/60 Hz 7794 104 84 4146 -20°C < Tamb < 55°C T5 T5 105°C
A D
B
C
E
Accessories
713.943.0340 | azz.com/rigalite
MHDS
Stainless Steel LED Lighting for Hazardous Locations
Key Features:
1 Heavy-duty, continuous seam welded 1/16” thick housing
2 Impact resistant 1/8” thick lens with reinforced corners 5
3 Convenient component assembly-tray held captive by two nylon
coated stainless steel cables
4 Toolless, cage-clamp terminal block
5 Two ¾” NPT conduit hubs 1 3
6 Field replaceable LED circuit boards and drivers with quick
disconnects
7 Toolless entry via over-the-center cam latches
7
4
1 BASIC LUMINAIRE
MHDS Stainless Steel LED
5 VOLTAGE/FREQUENCY
U = 120 - 277V 50/60 HZ
Class I, Division 2, Groups A, B, C and D A = 120V 60HZ1
Class II, Division 2 Groups F & G B = 220 - 240V 50/60HZ1
Class III C = 277V 60Hz1
UL 844 Hazardous Locations
UL 1598A Marine Outside Type
CSA C22.2 #137; C22.2 #213 6 OPTIONS1
UL 8750 LED Safety P = Polycarbonate Lens
Tested to LM 79 & LM 80 FB = Fuse Block1
55° C Ambient Temperature TW = Thru Wire
IP66 Cable Installations Only
PM = Pendant Mount
SP = Increased Surge Protection, 10kV
2 LAMP CURRENT/LAMP WATTAGE
30 = 3000K CCT
35 = 3500K CCT
07 = 74 Watt
50 = 5000K CCT
3 LAMP TYPE
L2 = LED (4000K CCT)
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
Options
LED
MHDS
Stainless Steel LED Lighting for Hazardous Locations
MHDS07L24U
Candlepower Distribution Coefficients of Utilization
Effective Floor Cavity Reflectance 0.20
0 15 30 45 60 75 90
% Effective
Ceiling
0 2553 2553 2553 2553 2553 2553 2553 Cavity 80 70 50 30 10 0
5 2523 2527 2536 2540 2544 2545 2551 Reflectance rcc
% Wall
10 2495 2496 2509 2510 2506 2508 2514 Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
15 2423 2432 2445 2455 2445 2438 2446 Room Cavity Ratio
RCR Effective Floor Cavity Reflectance 20%
20 2345 2354 2358 2358 2363 2351 2360
0 118 118 118 118 115 115 115 115 109 109 109 104 104 104 99 99 99 96
25 2235 2244 2256 2252 2249 2238 2240
30 2113 2120 2120 2124 2107 2109 2115
1 107 102 98 94 104 100 95 92 95 91 88 90 87 85 86 84 82 79
35 1964 1968 1978 1963 1981 2020 2033 2 97 89 81 76 94 86 80 74 82 77 72 78 74 70 75 71 68 65
40 1803 1807 1809 1815 1858 1845 1841 3 88 77 69 62 86 76 68 62 72 65 60 69 63 58 66 61 57 55
45 1619 1622 1624 1661 1649 1643 1668 4 81 68 59 53 78 67 58 52 64 57 51 61 55 50 58 53 49 46
50 1421 1424 1447 1457 1546 1621 1626
5 74 61 52 45 72 60 51 45 57 50 44 55 48 43 52 47 42 40
55 1213 1219 1250 1343 1447 1496 1497
60 1023 1035 1088 1262 1273 1302 1343
6 68 55 46 39 66 54 45 39 51 44 38 49 43 38 48 42 37 35
65 810 835 981 1051 1193 1138 1113 7 63 50 41 35 61 49 40 34 47 39 34 45 38 33 43 37 33 31
70 611 656 821 936 866 843 827 8 59 45 37 31 57 44 36 31 43 35 30 41 35 30 40 34 29 27
75 430 503 650 631 599 583 574 9 55 42 33 28 53 41 33 27 39 32 27 38 31 27 37 31 26 25
80 271 343 403 386 343 320 316 10 52 38 30 25 50 38 30 25 36 29 25 35 29 24 34 28 24 22
85 132 178 189 162 149 145 145
90 64 88 104 104 101 99 99
95 68 73 85 85 81 78 78
100 63 64 81 81 77 73 72
105 56 58 69 78 75 72 71
110
115
49
41
51
43
58
51
67
53
69
57
68
60
67
60
Photometric Data
120 34 35 43 46 47 50 51
125 29 29 36 43 43 42 43
130 25 25 31 38 41 41 41
135 23 23 27 32 37 40 40
140 22 21 24 29 31 34 35
145 21 20 21 26 28 30 31
150 0 0 0 0 0 0 0
LED
MHDS
Stainless Steel LED Lighting for Hazardous Locations
Certification Guide
Supply Wire
Lumen Class I, Div. 2, Class II, Div. 2.
Total Suitable
Model Length Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group F & G
Lumens Temperature,
Watt A, B, C & D Class III
°C
MHDS07L24U 4 ft 74W 120V - 277V 50/60 Hz 7794 104 84 4146 -20°C < Tamb < 55°C T5 T5 105°C
A D
B
C
E
Accessories
713.943.0340 | azz.com/rigalite
MHL LED
Linear LED Lighting for Hazardous Locations
Key Features:
1 Low-profile, lightweight design
2 Heavy-duty, 3/8" thick die-cast safety cable attachment points
3 Toolless, cage-clamp terminal block
4 Captive junction box cover, attached by nylon-coated stainless 1
steel cable
5 Field replaceable LED circuit boards and drivers with 7
quick disconnects
6 Adjustable mounting bracket with 60° range of 6
motion and nine locking positions* 2 5
7 Impact resistant clear lens 4 3
* Not included, must be ordered seperately. Please see options section.
MHL 07 - L - C - 4 - U - XX
1 2 3 4 5 6 7
1 BASIC SERIES
MHL Series1
5 NOMINAL FIXTURE LENGTH
2 = 2 Foot
Hazardous Locations 4 = 4 Foot
Class I, Division 2, Groups A, B, C & D
Class II, Division 2, Groups F & G
Class III
UL 1598A Marine Outside Type 6 VOLTAGE/ FREQUENCY
U = 120 - 277V 50/60HZ
UL 844 N = 347/480V 60HZ
UL 928 A = 120V 60HZ2
UL 8750 LED B = 220 - 240V 50/60HZ2
CSA C22.2 C = 277V 60HZ2
NEMA 4X
IP66
ETL Listed 7 OPTIONS
RIG = Mounting Bracket & (2) Safety Cables
MB = Mounting Bracket Ceiling or Wall
2 LAMP WATTAGE
07 = 80 Watt (4 foot)
EB = End Brackets Cable or Chain Suspension
HA = High Ambient 65°C Rated (4 ft. Model Only)
04 = 40 Watt (2 foot) EM = Emergency Battery Backup
SP = Increased Surge Protection, 10kV (Not available with
347/480V)
3 LAMP TYPE
L = LED (4000K CCT)
FB = Fuse Block (Not Available with 347/480V)2
SC = Safety Cable
30 = 3000K CCT
35 = 3500K CCT
4 LENS
C = Clear
50 = 5000K CCT
D = Diffused 1Mounting Hardware not inclued. Please see options for mounting selections.
2Specify voltage when option FB is needed. When option FB is selected, one
fuse is provided for 120 and 277V. Two fuses are provided for 220-240V. Fuse
option not available for marine listed fixtures, or for fixtures listed for use in
Canada.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
MHL LED
Linear LED Lighting for Hazardous Locations
Certification Guide
Options
Model Length Wattage Operating Voltage
Total
Lumen
per CRI CCT
Comparable Flourescent
Ambient Temperature
Class I,
Div. 2,
Class II,
Div. 2 Simultaneous
Supply Wire
Suitable
Lumens Luminaire Group Group F & G Presence Temperature,
Watt
A, B, C & D Class III °C
MHL04LC2 2 ft 40W 120V - 277V 50/60 Hz, 4068 101 84 4009 2 X 24W T5H0 / 2 X 35W TI2H0 -40°C < Tamb < 55°C T4A T4A T4A 90°C
MHL07LC4 4 ft 80W 347V/480V 60Hz 7654 102 84 4105 2 X 54W T5H0 / 2 X 60W TI2H0 -35°C < Tamb < 60°C T4A T4A T4A 90°C
MHL04LD2 2 ft 40W 120V - 277V 50/60 Hz, 3737 93 83 3916 2 X 24W T5H0 / 2 X 35W TI2H0 -40°C < Tamb < 55°C T4A T4A T4A 90°C
MHL07LD4 4 ft 80W 347V/480V 60Hz 7453 99 83 4034 2 X 54W T5H0 / 2 X 60W TI2H0 -35°C < Tamb < 60°C T4A T4A T4A 90°C
MHL07LC4-HA 4 ft 40W 120V - 277V 50/60 Hz, 7654 102 84 4105 2 X 54W T5H0 / 2 X 60W TI2H0 -30°C < Tamb < 65°C T4A T4A T4A 90°C
MHL07LD4-HA 4 ft 80W 347V/480V 60Hz 7453 99 83 4034 2 X 54W T5H0 / 2 X 60W TI2H0 -30°C < Tamb < 65°C T4A T4A T4A 90°C
MHL07LC4U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance rcc
80 70 50 30 10 0 Deg. 0 15 30 45 60 75 90
% Wall Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 2823 2823 2823 2823 2823 2823 2823
Room Cavity Ratio
RCR
Effective Floor Cavity Reflectance 20% 15 2729 2710 2712 2720 2722 2718 2719
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 25 2514 2529 2533 2537 2537 2514 2540
1 110 105 101 98 107 103 99 96 99 96 93 95 92 90 91 89 88 85 35 2259 2262 2262 2270 2270 2275 2282
2 100 92 86 80 98 90 84 79 87 82 78 84 79 76 81 77 74 72 45 1868 1879 1888 1910 1930 1915 1923
3 91 81 74 67 89 80 73 67 77 71 65 74 69 64 72 67 63 61 55 1400 1405 1418 1444 1460 1444 1449
4 84 72 64 57 82 71 63 57 68 61 56 66 60 55 64 59 54 52 65 748 737 821 901 934 965 972
5 77 65 56 49 75 63 55 49 61 54 48 59 53 48 58 52 47 45 75 117 164 450 367 337 381 403
6 71 58 49 43 69 57 49 43 55 48 42 54 47 42 52 46 42 40 85 29 29 30 32 35 45 56
7 66 53 44 38 64 52 44 38 50 43 38 49 42 37 48 42 37 35 95 0 0 0 0 0 30 35
8 61 48 40 34 60 47 39 34 46 39 34 45 38 33 44 38 33 31 105 0 0 0 0 0 0 0
9 57 44 36 31 56 44 36 30 42 35 30 41 35 30 40 34 30 28
10 54 41 33 28 53 40 33 28 39 32 27 38 32 27 37 31 27 25
MHL04LC2U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance rcc 80 70 50 30 10 0
Deg. 0 15 30 45 60 75 90
% Wall Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio 0 1445 1445 1445 1445 1445 1445 1445
RCR Effective Floor Cavity Reflectance 20%
15 1395 1396 1393 1401 1394 1397 1401
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 25 1308 1309 1305 1313 1308 1311 1311
1 109 104 100 96 106 102 98 94 98 94 91 94 91 89 90 88 86 84
35 1176 1173 1174 1180 1175 1174 1175
2 99 91 84 78 96 89 83 77 85 80 76 82 78 74 79 75 72 70
45 998 999 1006 998 995 996 998
3 90 80 72 65 88 78 71 65 75 69 64 73 67 62 70 65 61 59
55 749 759 773 781 774 771 771
4 83 71 62 56 81 70 61 55 67 60 54 65 59 54 63 57 53 51
65 505 510 502 501 489 495 499
5 76 63 55 48 74 62 54 48 60 53 47 58 52 47 56 51 46 44
75 221 215 211 222 198 177 133
6 70 57 48 42 69 56 48 42 54 47 41 53 46 41 51 45 41 39
85 34 34 13 11 9 8 8
7 65 52 43 37 64 51 43 37 50 42 37 48 41 36 47 41 36 34
95 13 10 9 8 7 7 7
8 61 47 39 33 59 47 39 33 45 38 33 44 38 33 43 37 32 31
105 12 0 0 0 0 0 0
9 57 44 35 30 56 43 35 30 42 35 30 41 34 30 40 34 29 28
115 11 0 0 0 0 0 0
10 53 40 32 27 52 40 32 27 39 32 27 38 31 27 37 31 27 25
LED
MHL LED
Linear LED Lighting for Hazardous Locations
MHL07LD4U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance rcc 80 70 50 30 10 0 Deg. 0 15 30 45 60 75 90
% Wall Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 2836 2836 2836 2836 2836 2836 2836
Room Cavity Ratio
RCR Effective Floor Cavity Reflectance 20% 15 2687 2679 2682 2683 2679 2672 2671
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 25 2424 2427 2428 2430 2424 2415 2414
1 109 104 100 96 106 102 98 94 98 94 91 94 91 89 90 88 86 84 35 2098 2094 2093 2090 2084 2072 2070
2 99 91 84 78 96 89 83 77 85 80 76 82 78 74 79 75 72 70 45 1715 1713 1710 1700 1694 1679 1679
3 90 80 72 65 88 78 71 65 75 69 64 73 67 62 70 65 61 59 55 1317 1313 1309 1295 1280 1264 1260
4 83 71 62 56 81 70 61 55 67 60 54 65 59 54 63 57 53 51 65 928 925 920 909 889 868 859
5 76 63 55 48 74 62 54 48 60 53 47 58 52 47 56 51 46 44 75 498 502 501 494 478 455 440
6 70 57 48 42 69 56 48 42 54 47 41 53 46 41 51 45 41 39 85 77 80 88 96 98 103 93
7 65 52 43 37 64 51 43 37 50 42 37 48 41 36 47 41 36 34 95 0 0 0 0 0 26 27 Photometric Data
8 61 47 39 33 59 47 39 33 45 38 33 44 38 33 43 37 32 31 105 0 0 0 0 0 0 0
9 57 44 35 30 56 43 35 30 42 35 30 41 34 30 40 34 29 28
10 53 40 32 27 52 40 32 27 39 32 27 38 31 27 37 31 27 25
MHL04LD2U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance rcc 80 70 50 30 10 0
Deg. 0 15 30 45 60 75 90
% Wall Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio 0 1373 1373 1373 1373 1373 1373 1373
RCR Effective Floor Cavity Reflectance 20%
15 1303 1304 1304 1311 1306 1309 1312
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 25 1183 1185 1187 1195 1192 1196 1198
1 109 104 99 96 106 101 98 94 97 94 91 93 91 88 90 87 85 83
35 1318 1021 1027 1035 1037 1041 1043
2 99 90 84 78 96 89 82 77 85 80 75 82 77 73 78 75 72 69
45 827 831 842 850 856 861 863
3 90 79 71 65 88 78 70 64 75 68 63 72 66 62 69 65 61 58
55 624 631 646 656 664 670 672
4 82 70 62 55 80 69 61 54 67 59 54 64 58 53 62 57 52 50
65 423 432 448 460 467 471 472
5 76 63 54 48 74 62 53 47 60 52 46 58 51 46 56 50 45 43
75 229 239 254 263 268 269 270
6 70 57 48 41 68 56 47 41 54 46 41 52 45 40 51 45 40 38
85 54 64 64 59 60 62 64
7 65 51 43 37 63 51 42 36 49 42 36 48 41 36 46 40 36 34
95 11 11 10 8 7 7 6
8 61 47 39 33 59 46 38 33 45 38 32 44 37 32 42 36 32 30
105 0 0 0 0 0 0 0
9 57 43 35 29 55 43 35 29 41 34 29 40 34 29 39 33 29 27
10 53 40 32 27 52 39 32 27 38 31 27 37 31 26 36 31 26 24
LED
MHL LED
Linear LED Lighting for Hazardous Locations
Accessories
713.943.0340 | azz.com/rigalite
MHLS LED
Stainless Steel LED Lighting for Hazardous Locations
Key Features:
1 Low-profile, lightweight design
2 Integral safety cable attachment points
3 Toolless, cage-clamp terminal block
4 Captive junction box cover, attached by nylon-coated stainless 1
steel cable
5 Field replaceable LED circuit boards and drivers with 2
quick disconnects 7
6 Adjustable mounting bracket with 60° range of
6
motion and nine locking positions* 5
7 Impact resistant clear lens 4 3
* Not included, must be ordered seperately. Please see options section.
MHLS 07 - L - C - 4 - U - XX
1 2 3 4 5 6 7
1 BASIC SERIES
MHLS LED1
5 NOMINAL FIXTURE LENGTH
2 = 2 Foot
Hazardous Locations 4 = 4 Foot
Class I, Division 2, Groups A, B, C & D
Class II, Division 2, Groups F & G
Class III
UL 1598A Marine Outside Type
6 VOLTAGE/ FREQUENCY
U = 120 - 277V 50/60HZ
UL 844 A = 120V 60HZ2
UL 928 B = 220 - 240V 50/60HZ2
UL 8750 LED C = 277V 60HZ2
CSA C22.2
NEMA 4X
IP66
7 OPTIONS
RIG = Mounting Bracket & (2) Safety Cables
MB = Mounting Bracket Ceiling or Wall
2 LAMP WATTAGE
07 = 80 Watt (4 foot)
EB = End Brackets Cable or Chain Suspension
EM = Emergency Battery Backup
04 = 40 Watt (2 foot) SP = Increased Surge Protection, 10kV
FB = Fuse Block
SC = Safety Cable
3 LAMP TYPE
L = LED (4000K CCT)
30 = 3000K CCT
35 = 3500K CCT
50 = 5000K CCT
316 = Stainless Steel
4 LENS
C = Clear 1Mounting Hardware not included. Please see options for mounting selections.
D = Diffused 2Specify voltage when option FB is needed. When option FB is selected, one
fuse is provided for 120 and 277V. Two fuses are provided for 220-240V. Fuse
option not available for marine listed fixtures, or for fixtures listed for use in
Canada.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
MHLS
Stainless Steel LED Lighting for Hazardous Locations
Certification Guide
Options Model Length Wattage Operating Voltage
Total
Lumen
per CRI CCT Ambient Temperature
Class I,
Div. 2,
Class II, Div. 2
Group F & G
Simultaneous
Supply Wire
Suitable
Lumens Group Presence Temperature,
Watt Class III
A, B, C & D °C
MHLS04LC2 2 ft 40W 4068 101 84 4009 -40°C < Tamb < 45°C T4A T4A T4A 90°C
MHLS07LC4 4 ft 80W 120V - 277V 50/60 Hz 7654 102 84 4105 -35°C < Tamb < 45°C T4A T4A T4A 90°C
MHLS04LD2 2 ft 40W 3737 93 83 3916 -40°C < Tamb < 45°C T4A T4A T4A 90°C
MHLS07LD4 4 ft 80W 7453 99 83 4034 -35°C < Tamb < 45°C T4A T4A T4A 90°C
MHLS07LC4U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance rcc
80 70 50 30 10 0 Deg. 0 15 30 45 60 75 90
% Wall Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 2823 2823 2823 2823 2823 2823 2823
Room Cavity Ratio
RCR
Effective Floor Cavity Reflectance 20% 15 2729 2710 2712 2720 2722 2718 2719
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 25 2514 2529 2533 2537 2537 2514 2540
1 110 105 101 98 107 103 99 96 99 96 93 95 92 90 91 89 88 85 35 2259 2262 2262 2270 2270 2275 2282
2 100 92 86 80 98 90 84 79 87 82 78 84 79 76 81 77 74 72 45 1868 1879 1888 1910 1930 1915 1923
3 91 81 74 67 89 80 73 67 77 71 65 74 69 64 72 67 63 61 55 1400 1405 1418 1444 1460 1444 1449
4 84 72 64 57 82 71 63 57 68 61 56 66 60 55 64 59 54 52 65 748 737 821 901 934 965 972
5 77 65 56 49 75 63 55 49 61 54 48 59 53 48 58 52 47 45 75 117 164 450 367 337 381 403
6 71 58 49 43 69 57 49 43 55 48 42 54 47 42 52 46 42 40 85 29 29 30 32 35 45 56
7 66 53 44 38 64 52 44 38 50 43 38 49 42 37 48 42 37 35 95 0 0 0 0 0 30 35
8 61 48 40 34 60 47 39 34 46 39 34 45 38 33 44 38 33 31 105 0 0 0 0 0 0 0
9 57 44 36 31 56 44 36 30 42 35 30 41 35 30 40 34 30 28
10 54 41 33 28 53 40 33 28 39 32 27 38 32 27 37 31 27 25
MHLS04LC2U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance rcc 80 70 50 30 10 0
Deg. 0 15 30 45 60 75 90
% Wall Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio 0 1445 1445 1445 1445 1445 1445 1445
RCR Effective Floor Cavity Reflectance 20%
15 1395 1396 1393 1401 1394 1397 1401
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 25 1308 1309 1305 1313 1308 1311 1311
1 109 104 100 96 106 102 98 94 98 94 91 94 91 89 90 88 86 84
35 1176 1173 1174 1180 1175 1174 1175
2 99 91 84 78 96 89 83 77 85 80 76 82 78 74 79 75 72 70
45 998 999 1006 998 995 996 998
3 90 80 72 65 88 78 71 65 75 69 64 73 67 62 70 65 61 59
55 749 759 773 781 774 771 771
4 83 71 62 56 81 70 61 55 67 60 54 65 59 54 63 57 53 51
65 505 510 502 501 489 495 499
5 76 63 55 48 74 62 54 48 60 53 47 58 52 47 56 51 46 44
75 221 215 211 222 198 177 133
6 70 57 48 42 69 56 48 42 54 47 41 53 46 41 51 45 41 39
85 34 34 13 11 9 8 8
7 65 52 43 37 64 51 43 37 50 42 37 48 41 36 47 41 36 34
95 13 10 9 8 7 7 7
8 61 47 39 33 59 47 39 33 45 38 33 44 38 33 43 37 32 31
105 12 0 0 0 0 0 0
9 57 44 35 30 56 43 35 30 42 35 30 41 34 30 40 34 29 28
115 11 0 0 0 0 0 0
10 53 40 32 27 52 40 32 27 39 32 27 38 31 27 37 31 27 25
LED
MHLS
Stainless Steel LED Lighting for Hazardous Locations
MHLS07LD4U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance rcc 80 70 50 30 10 0 Deg. 0 15 30 45 60 75 90
% Wall Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 2836 2836 2836 2836 2836 2836 2836
Room Cavity Ratio
RCR Effective Floor Cavity Reflectance 20% 15 2687 2679 2682 2683 2679 2672 2671
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 25 2424 2427 2428 2430 2424 2415 2414
1 109 104 100 96 106 102 98 94 98 94 91 94 91 89 90 88 86 84 35 2098 2094 2093 2090 2084 2072 2070
2 99 91 84 78 96 89 83 77 85 80 76 82 78 74 79 75 72 70 45 1715 1713 1710 1700 1694 1679 1679
3 90 80 72 65 88 78 71 65 75 69 64 73 67 62 70 65 61 59 55 1317 1313 1309 1295 1280 1264 1260
4 83 71 62 56 81 70 61 55 67 60 54 65 59 54 63 57 53 51 65 928 925 920 909 889 868 859
5 76 63 55 48 74 62 54 48 60 53 47 58 52 47 56 51 46 44 75 498 502 501 494 478 455 440
6 70 57 48 42 69 56 48 42 54 47 41 53 46 41 51 45 41 39 85 77 80 88 96 98 103 93
7 65 52 43 37 64 51 43 37 50 42 37 48 41 36 47 41 36 34 95 0 0 0 0 0 26 27 Photometric Data
8 61 47 39 33 59 47 39 33 45 38 33 44 38 33 43 37 32 31 105 0 0 0 0 0 0 0
9 57 44 35 30 56 43 35 30 42 35 30 41 34 30 40 34 29 28
10 53 40 32 27 52 40 32 27 39 32 27 38 31 27 37 31 27 25
MHLS04LD2U
Coefficients of Utilization Candlepower Distribution Photometric Data
% Effective Ceiling
Cavity Reflectance rcc 80 70 50 30 10 0
Deg. 0 15 30 45 60 75 90
% Wall Reflectance rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio 0 1373 1373 1373 1373 1373 1373 1373
RCR Effective Floor Cavity Reflectance 20%
15 1303 1304 1304 1311 1306 1309 1312
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 25 1183 1185 1187 1195 1192 1196 1198
1 109 104 99 96 106 101 98 94 97 94 91 93 91 88 90 87 85 83
35 1318 1021 1027 1035 1037 1041 1043
2 99 90 84 78 96 89 82 77 85 80 75 82 77 73 78 75 72 69
45 827 831 842 850 856 861 863
3 90 79 71 65 88 78 70 64 75 68 63 72 66 62 69 65 61 58
55 624 631 646 656 664 670 672
4 82 70 62 55 80 69 61 54 67 59 54 64 58 53 62 57 52 50
65 423 432 448 460 467 471 472
5 76 63 54 48 74 62 53 47 60 52 46 58 51 46 56 50 45 43
75 229 239 254 263 268 269 270
6 70 57 48 41 68 56 47 41 54 46 41 52 45 40 51 45 40 38
85 54 64 64 59 60 62 64
7 65 51 43 37 63 51 42 36 49 42 36 48 41 36 46 40 36 34
95 11 11 10 8 7 7 6
8 61 47 39 33 59 46 38 33 45 38 32 44 37 32 42 36 32 30
105 0 0 0 0 0 0 0
9 57 43 35 29 55 43 35 29 41 34 29 40 34 29 39 33 29 27
10 53 40 32 27 52 39 32 27 38 31 27 37 31 26 36 31 26 24
LED
MHLS
Stainless Steel LED Lighting for Hazardous Locations
Accessories
713.943.0340 | azz.com/rigalite
RFNK62
Linear LED Lighting for Hazardous Locations
3
Key Features:
1 Rugged 1/16” thick continuous seam-welded housing
2 Narrow profile design
7
3 Two heavy-duty, 1/8” thick permanent safety cable attachment points
4 Toolless entry latch system with captive hardware
5 Field replaceable LED circuit boards and drivers with quick
1
disconnects
6 Toolless, cage-clamp terminal block
7 One 1/2” NPT Hub 5
4
6
RFNK262 07 - L - 4 - U - XX
1 2 3 4 5 6
1 BASIC LUMINAIRE
RFNK262 LED
5 VOLTAGE/FREQUENCY
U = 120 - 277V 50/60 HZ
Class I, Division 2, Groups A, B, C & D A = 120V 60 HZ1
UL 1598 Suitable for Outdoor Wet Locations B = 220 - 240V 50/60 HZ1
UL 8750 C = 277V 60 HZ1
CSA C22.2 No. 250.0
CSA C22.2 No. 137
NEMA 4X
Tested to LM 79 and 80
6 OPTIONS1
FB = Fuse Block1
-20°C to 55°C Ambient Temperature TW = Thru Wire
Cable Installations Only
30 = 3000K CCT
2 LAMP CURRENT/LAMP WATTAGE 35 = 3500K CCT
07 = 74 Watt (4 foot) 50 = 5000K CCT
06 = 56 Watt (2 foot)
3 LAMP TYPE
L = LED (4000K CCT)
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
RFNK262
Linear LED Lighting for Hazardous Locations
Accessories
Offset Mounting Bracket Adjustable Mounting Bracket
Fixture Dimensions
A
50.38/24.00
51.38/25.00
D
C
Certification Guide
Supply Wire
Lumen Class I, Div. 2, Hub
Total Suitable
Model Length Wattage Operating Voltage per CRI CCT Ambient Temperature Group Size
Lumens Temperature,
Watt A, B, C & D (NPT)
°C
RFNK26207L4U 4 ft 74W 120V - 277V 50/60 Hz 7423 99 84 4100 -20°C < Tamb < 55°C T6 105°C 1/2”
RFNK26206L2U 2 ft 56W 120V - 277V 50/60 Hz 5305 95 84 4100 -20°C < Tamb < 55°C T6 105°C 1/2”
713.943.0340 | azz.com/rigalite 9
XML LED
Explosionproof Linear LED Lighting
Key Features:
1 Low-profi le, lightweight design
2 Convenient wiring access through screw-cap cover
with toolless, cage clamp terminal block 1
3 Self-contained emergency battery backup, no 4
additional junction box required 6
4 Heavy-duty, 7/16" thick die-cast safety cable 5
attachment points 2 3
5 Replaceable LED circuit boards and drivers
6 Adjustable Mounting bracket with 90 degree range of
motion and 13 locking positions
XML 07 - L - C - 4 - U - X X
1 2 3 4 5 6 7
1 Series 6 VOLTAGE/FREQUENCY
XML LED1 U = 120 Thru 277V 50/60 HZ
N = 347/480V 60 HZ
A = 120V 60 HZ
2 LAMP WATTAGE B = 220 - 240V 50/60 HZ
04 = 40 Watt (2 ft.) C = 277V 60 HZ
05 = 45 Watt (2 ft.)
07 = 75 Watt (4 ft.)
09 = 87 Watt (4 ft.)
7 OPTIONS
RIG = Mounting Bracket & (2) Safety Cables
3 LAMP TYPE MB = Mounting Bracket Ceiling or Wall
L = LED (4000 K CCT) HA = High Ambient 65ºC Rated (4ft. Model Only)
EM = Emergency Battery Backup (Not Available with
347/480V)
LENS
4 C = Clear
FB = Fuse Block2
PB = Push to Test Switch for EM Option Only
D = Diffused 30 = 3000K (CCT)
35 = 3500K (CCT)
50 = 5000K (CCT)
5 NOMINAL FIXTURE LENGTH
2 = 2 Foot
4 = 4 Foot
Certification Guide
Supply Wire
Class I, Div. 1, Class II, Div. 1.
Total Lumen Simultaneous Suitable
Model Length Wattage Operating Voltage CRI CCT Comparable Fluorescent Luminaire Ambient Temperature Group Group E, F & G
Lumens per Watt Presence Temperature,
C & D Class III
°C
XML04LD2U 2 ft 40W 120V - 277V 50/60 Hz 2815 84.7 82 4071 2 X 24W T5H0 / 2 X 35W T12H0 -40°C < Tamb < 55°C T6 T6 T6 90°C
XML04LD2N 2 ft 40W 347V/480V 60 Hz 2815 84.7 82 4071 2 X 24W T5H0 / 2 X 35W T12H0 -40°C < Tamb < 55°C T6 T6 T6 90°C
XML05LD2U 2 ft 45W 120V - 277V 50/60 Hz 4160 98.3 83 3983 3 X 24W T5H0 / 3 X 35W T12H0 -40°C < Tamb < 50°C T6 T6 T6 90°C
XML05LD2N 2 ft 45W 347V/480V 60 Hz 4160 98.3 83 3983 3 X 24W T5H0 / 3 X 35W T12H0 -40°C < Tamb < 50°C T6 T6 T6 90°C
XML07LD4U 4 ft. 80W 120V - 277V 50/60 Hz 5836 85.2 82 4183 2 X 54W T5H0 / 2 X 60W T12H0 -35°C < Tamb < 60°C T6 T6 T6 90°C
XML07LD4N 4 ft. 80W 347V/480V 60 Hz 5836 85.2 82 4183 2 X 54W T5H0 / 2 X 60W T12H0 -35°C < Tamb < 60°C T6 T6 T6 90°C
XML07LD4U-HA 4 ft. 80W 120V - 277V 50/60 Hz 5836 85.2 82 4183 2 X 54W T5H0 / 2 X 60W T12H0 -30°C < Tamb < 65°C T6 T5 T5 90°C
XML09LD4U 4 ft. 87W 120V - 277V 50/60 Hz 8463 97.2 83 4096 3 X 54W T5H0 / 3 X 60W T12H0 -35°C < Tamb < 60°C T6 T6 T6 90°C
XML09LD4N 4 ft. 87W 347V/480V 60 Hz 8463 97.2 83 4096 3 X 54W T5H0 / 3 X 60W T12H0 -35°C < Tamb < 60°C T6 T6 T6 90°C
Certification Guide
Supply Wire
Class I, Div. 1, Class II, Div. 1.
Total Lumen Comparable Fluorescent Simultaneous Suitable
Model Length Wattage Operating Voltage CRI CCT Ambient Temperature Group Group E, F & G
Lumens per Watt Luminaire Presence Temperature,
C & D Class III
°C
XML04LC2U 2 ft 40W 120V - 277V 50/60 Hz 3654 109.9 82 4096 2 X 24W T5H0 / 2 X 35W T12H0 -40°C < Tamb < 55°C T6 T6 T6 90°C
XML04LC2N 2 ft 40W 347V/480V 60 Hz 3654 109.9 82 4096 2 X 24W T5H0 / 2 X 35W T12H0 -40°C < Tamb < 55°C T6 T6 T6 90°C
XML05LC2U 2 ft 45W 120V - 277V 50/60 Hz 5364 126.4 84 3975 3 X 24W T5H0 / 3 X 35W T12H0 -40°C < Tamb < 50°C T6 T6 T6 90°C
XML05LC2N 2 ft 45W 347V/480V 60 Hz 5364 126.4 84 3975 3 X 24W T5H0 / 3 X 35W T12H0 -40°C < Tamb < 50°C T6 T6 T6 90°C
XML07LC4U 4 ft. 80W 120V - 277V 50/60 Hz 7743 112.9 82 4107 2 X 54W T5H0 / 2 X 60W T12H0 -35°C < Tamb < 60°C T6 T6 T6 90°C
XML07LC4N 4 ft. 80W 347V/480V 60 Hz 7743 112.9 82 4107 2 X 54W T5H0 / 2 X 60W T12H0 -35°C < Tamb < 60°C T6 T6 T6 90°C
XML07LC4U-HA 4 ft. 80W 120V - 277V 50/60 Hz 7743 112.9 82 4107 2 X 54W T5H0 / 2 X 60W T12H0 -30°C < Tamb < 65°C T6 T5 T5 90°C
XML09LC4U 4 ft. 87W 120V - 277V 50/60 Hz 11450 131.3 83 4000 3 X 54W T5H0 / 3 X 60W T12H0 -35°C < Tamb < 60°C T6 T6 T6 90°C
XML09LC4N 4 ft. 87W 347V/480V 60 Hz 11450 131.3 83 4000 3 X 54W T5H0 / 3 X 60W T12H0 -35°C < Tamb < 60°C T6 T6 T6 90°C
Accessories
Mounting Bracket Beam Clamp Beam Clamp Mounting Kit Safety Cable
Ceiling or Wall Catalog Number: 38083 Catalog Number: 53010 Catalog Number: 10128R
Catalog Number: 26897 Shipping Weight: 1.25 lbs. Shipping Weight: 3 lbs. Shipping Weight: 1 lb.
Shipping Weight: 2 lbs.
XP LED X
P
Explosionproof Linear LED Lighting
•
L
Class I, Division 1, Groups C & D
• Class I, Division 2, Groups C & D
• Class II, Division 1 & 2, Groups E, F & G E
• Class III D
• Class I, Zone 1, Groups IIA and IIB
• Class I, Zone 2, Groups IIA, IIB and IIC
• UL 844 Hazardous Locations
• UL 924 Emergency Lighting
• Simultaneous Presence
• UL 1598A Marine Outside Type
• UL 1598 Wet Locations
• NEMA 4X, 7CD & 9EFG
• CUL
• IP66
• UL 8750 LED Safety
• Paint Spray Booth
• Emergency Battery Backup
• 55ºC Ambient Temperature
• Tested to LM 79 & LM 80
• Patent Pending
713.943.0340 | azz.com/rigalite 9
XP LED
Explosionproof Linear LED Lighting
Key Features:
1 Two permanent safety cable attachment points 6
2 Field replaceable LED circuit boards and drivers with 5
quick disconnects 3
3 Convenient wiring access though screw-cap covers 1
4 Self-contained emergency battery back-up (optional)
5 Oversized, finned driver housing for greater heat 4
dissipation
6 Factory Sealed
XP 75L - 4 - 3L - U - XX
1 2 3 4 5 6
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
XP
XP Series
Two Tube XP
Certification Guide
Supply Wire
Class I, Div. 1, Class II, Div. 1. Shipping
Total Lumen Simultaneous Suitable
Model Length Wattage Operating Voltage CRI CCT Ambient Temperature Group Group E, F & G Hub Size Weight
Lumens per Watt Presence Temperature,
C&D Class III (lbs)
°C
XP30L22LU 2 ft 30W 120V - 277V 50/60 Hz 2783 105 84 3965 -20°C < Tamb < 55°C T6 T4A T4A 75°C 1/2 in. NPT 40
XP50L42LU 4 ft 46W 120V - 277V 50/60 Hz 5450 116 84 4097 -20°C < Tamb < 55°C T6 T4A T4A 75°C 1/2 in. NPT 65
Hub Size
Two Tube Fixture Description Voltage Catalog Number
(inches)
Two Foot
30 Watt LED- 24" 1/2 120-277V 50/60 HZ XP30L-2-2L-U
Three Tube XP
Certification Guide
Supply Wire
Class I, Div. 1, Class II, Div. 1. Shipping
Total Lumen Simultaneous Suitable
Model Length Wattage Operating Voltage CRI CCT Ambient Temperature Group Group E, F & G Hub Size Weight
Lumens per Watt Presence Temperature,
C&D Class III (lbs)
°C
XP40L23LU 2 ft 40W 120V - 277V 50/60 Hz 4110 103 84 4100 -20°C < Tamb < 55°C T6 T5 T5 75°C 3/4 in. NPT 47
XP75L43LU 4 ft 73W 120V - 277V 50/60 Hz 8220 112 84 4122 -20°C < Tamb < 55°C T6 T5 T5 75°C 3/4 in. NPT 78
Hub Size
Three Tube Fixture Description Voltage Catalog Number
(inches)
Two Foot
40 Watt LED- 24" 3/4 120-277V 50/60 HZ XP40L-2-3L-U
Four Tube XP
Certification Guide
Supply Wire
Class I, Div. 1, Class II, Div. 1. Shipping
Total Lumen Simultaneous Suitable
Model Length Wattage Operating Voltage CRI CCT Ambient Temperature Group Group E, F & G Hub Size Weight
Lumens per Watt Presence Temperature,
C&D Class III (lbs)
°C
XP100L44LU 4 ft 93W 120V - 277V 50/60 Hz 10918 117 84 4153 -20°C < Tamb < 55°C T6 T4A T4A 75°C 3/4 in. NPT 138
Hub Size
Four Tube Fixture Description Voltage Catalog Number
(inches)
Accessories
POLYCARBONATE SHIELDS
DESCRIPTION CATALOG NUMBER
STAINLESS STEEL GUARDS 3-Lamp 2-Ft. Fixtures 86000
DESCRIPTION CATALOG NUMBER 2-Lamp 2-Ft. Fixtures 86001
2-Lamp 2-Ft. Fixtures 86321 2-Lamp 4-Ft. Fixtures 86002
2-Lamp 4-Ft. Fixtures 86320 3-Lamp 4-Ft. Fixtures 86003*
3-Lamp 4-Ft. Fixtures 86345 Four Lamp Fixtures Require Two Cat. #86002 Shields.
Four Lamp Fixtures Require Two Cat. #86320 Guards *One 86345 guard required.
Typical Installations
BEAM
DROP
SHOCK
WALL OR CEILING
LED
XP
Explosionproof Linear LED Lighting
SWIVEL
RIGID
FLEXIBLE
FPF LED SERIES F
P
Linear Non-Metallic Fixture for Food Processing
F
• NSF Certified Food Equipment
• High Pressure Hose Down
• UL 1598 Wet Locations
L
• UL 8750 LED Safety E
• UL 924 Emergency Lighting
• CUL
D
• Non-Metallic LED Fixture
• Tested to LM 79, LM 80
• 85 CRI
• Available with Emergency Battery Backup
713.943.0340 | azz.com/rigalite
FPF LED SERIES
Non-Metallic Fixture for Food Processing
Impact resistant DR
acrylic housing. Stainless steel
external hardware.
Industry leading
watershed design.
318
LED
FPF LED Series
Non-Metallic Housing • UL 1598 Wet Locations • UL 8750 LED Safety • High Pressure Hose Down • Indoor or Outdoor • NSF Certified
FPF 07L-4-U-XX
1 2 3 4 5
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
319
LED
FPF LED Series
Non-Metallic Housing • UL 1598 Wet Locations • UL 8750 LED Safety • High Pressure Hose Down • Indoor or Outdoor • NSF Certified
LED Series
Description Voltage Catalog Number*
Two Foot
36 Watt LED System, 24” 120-277V 50/60HZ FPF04L-2-U
Fixture
Four Foot
72 Watt LED System, 48" 120-277V 50/60HZ FPF07L-4-U
Fixture
Eight Foot
144 Watt LED System, 96" 120-277V 50/60HZ FPF14L-8-U
Fixture
Fixtures are furnished with stainless steel chain mount kit, non-metallic cord grip and 3 ft. long #16 AWG 3 conductor type SOA cable.
Accessories
Fixed Mounting Bracket Kit Chain Mounting Kit Stainless Steel Band Clamp
Stainless Steel - For 3/8 in. Bolts (not provided) Stainless Steel Catalog Number: FPFBNDMKT
Catalog Number: FPFXDMKT Catalog Number: FPFCMKT1 Shipping Weight: 1.0 lbs.
Shipping Weight: 0.4 lbs. Shipping Weight: 0.2 lbs.
Mini Receptacle 3P Male Pigtail Assembly- 3 ft. Cable Mini Plug 3P- 6 ft. Mini Cable
Catalog Number: 64005 Other Lengths Available - Consult Factory Other Lengths Available - Consult Factory
Shipping Weight: 0.1 lbs. Catalog Number: 53108 Catalog Number: 60006R
Shipping Weight: 0.4 lbs. Shipping Weight: 0.6 lbs.
321
LED
FPF LED Series
Non-Metallic Housing • UL 1598 Wet Locations • UL 8750 LED Safety • High Pressure Hose Down • Indoor or Outdoor • NSF Certified
Coefficients of Utilization
FPF07L4UXX
% Effective Ceiling
Cavity Reflectance RCC 80 70 50 30 10 0
% Wall Reflectance RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR Effective Floor Cavity Reflectance 20%
0 119 119 119 119 116 116 116 116 110 110 110 105 105 105 101 101 101 99
1 110 106 102 98 107 103 100 97 99 96 93 95 92 90 91 89 87 85
2 101 94 88 83 98 92 86 82 88 84 80 85 81 78 82 78 76 74
3 93 84 77 71 91 82 75 70 79 73 69 76 71 67 74 70 66 64
4 86 75 67 61 84 74 67 61 71 65 60 69 64 59 67 62 58 56
5 80 68 60 54 78 67 59 54 65 58 53 63 57 52 61 56 52 50
6 74 62 54 48 72 61 53 48 59 52 47 57 51 47 56 50 46 44
7 69 57 49 43 67 56 48 43 54 47 42 53 47 42 51 46 42 40
8 65 52 44 39 63 51 44 39 50 43 38 49 42 38 47 42 38 36
9 61 48 40 35 59 47 40 35 46 39 35 45 39 35 44 38 34 33
10 57 44 37 32 56 44 37 32 43 36 32 42 36 32 41 35 31 30
713.943.0340 | azz.com/rigalite
SAFJ HI-LUMEN LED
LED Area Lighting for Hazardous Locations
Key Features:
1 Wide distribution pattern
2 Field replaceable LEDs and drivers
3 Hinged mount for easy access to internal components
4 Isolated LED compartment reduces temperature within driver housing
5 Unique design enhances airflow for greater heat dissipation
6 Heavy-duty tempered glass lens 3
7 Type I, III and V light distribution options
1 4
6
7
224
LED
SAFJ HI-LUMEN
LED Area Lighting for Hazardous Locations
1 BASIC LUMINAIRE
SAFJ LED1
7 GUARD
G = Stainless Wire Guard
2 8 MOUNTING STYLE
LAMP CURRENT / LAMP WATTAGE P = ¾" Pendant Mount
16 = 160 Watts P1 = 1" Pendant Mount
21 = 210 Watts C = ¾" Ceiling Mount
24 = 240 Watts C1 = 1" Ceiling Mount
W = ¾" Wall Mount
3 LAMP TYPE W1 = 1" Wall Mount
L3 = LED S = 1-¼" 25°Stanchion Mount
S1 = 1-½" 25°Stanchion Mount
L = 1-¼" 90°Stanchion Mount
4 DRIVER VOLTAGE L1 = 1-½" 90°Stanchion Mount
U = 120-277V 50/60HZ
N = 347/480V 60HZ 9 OPTIONS1
FB1 = Single Fuse Block 2,3
FB2 = Double Fuse Block 2,3
5 GLOBE 30 = 3000K CCT
G = Clear Glass Globe 35 = 3500K CCT
40 = 4000K CCT
6
1 Consult factory for pricing.
OPTICS 2 Not available with universal driver unless incoming voltage is specified.
Blank = Type V Light Distribution When installed, one fuse block is provided for 120 & 277V
and two fuse blocks are provided for 208, 220, 240, 347 and 480V.
1 = Type I Light Distribution Fuse not provided.
3 = Type III Light Distribution 3 FB option not available for marine listed fixtures.
Part numbering logic is for explaining catalog part structure only. Not all combinations are possible; consult factory for catalog num-
bers not listed on chart.
225
LED
SAFJ HI-LUMEN
LED Area Lighting for Hazardous Locations
Certification Guide
Supply Wire
Class I, Div. 2,
Total Lumens Suitable
Model Mount Wattage Operating Voltage CRI CCT Ambient Temperature Group
Lumens per Watt Temperature,
A, B, C & D
°C
SAFJ16L3UG P, C, W, S, L 160W 20,088 125.2 82.6 5035 -30°C < Tamb < 65°C* T2D 90°C
SAFJ16L3UG1 P, C, W, S, L 160W 14,345 89.1 85.3 5178 -30°C < Tamb < 55°C T2B 90°C
SAFJ16L3UG3 P, C, W, S, L 160W 16,708 103.6 84.3 5065 -30°C < Tamb < 55°C T3 90°C
SAFJ21L3UG P, C, W, S, L 210W 26,001 128.1 82.5 4994 -30°C < Tamb < 65°C* T2D 90°C
120V - 277V 50/60 Hz,
SAFJ21L3UG1 P, C, W, S, L 210W 18,184 89.6 85.3 5171 -30°C < Tamb < 55°C T2B 90°C
347V/480V 60Hz
SAFJ21L3UG3 P, C, W, S, L 210W 21,023 103.6 84.3 5037 -30°C < Tamb < 55°C T3 90°C
SAFJ24L3UG P, C, W, S, L 240W 30,815 127.6 83.7 5003 -30°C < Tamb < 65°C* T2D 90°C
SAFJ24L3UG1 P, C, W, S, L 240W 21,813 90.5 86.7 5199 -30°C < Tamb < 55°C T2B 90°C
SAFJ24L3UG3 P, C, W, S, L 240W 25,370 105.1 85.7 5076 -30°C < Tamb < 55°C T3 90°C
Photometric Data
SAFJ16L3UG SAFJ21L3UG SAFJ24L3UG
233 233
LED
SAFJ HI-LUMEN
LED Area Lighting for Hazardous Locations
Wall Mount
Fixture Weight
SAFJ24L3UG 45 lbs.
SAFJ21L3UG 43 lbs.
SAFJ16L3UG 41 lbs.
234 234
LED
SAFJ HI-LUMEN
LED Area Lighting for Hazardous Locations
Conduit Shipping
Outlet Catalog Shipping
Hub Size Weight Globes
Boxes No. Catalog No. Description Weight
(In.) (Lbs.) And Guards (Lbs.)
Rigid Pendant
Guard
JMP 3/4 3.0
Stainless Steel
86324 Wire Guard 1.0
JMC1 1 3.5
Wall Mount
JMW 3/4 6.0
JMW1 1 6.0
235
SAFJ LED S
A
LED Area Lighting for Hazardous Locations
• Class I, Division 2, Groups A, B, C, & D F
• Class II, Division 1 & 2, Groups E, F & G J
• Class III
• UL 1598A Marine Outside Type
L
• UL 1598 Wet Locations
• UL 844 Hazardous Locations
E
• UL 8750 LED Safety D
• ABS Type Approved
• Tested to LM 79 & LM 80
• 55° C Ambient Temperature
• Simultaneous Presence
• US Patent # D637,340S
• NEMA 4X
• IP66
• CUL
713.943.0340 | azz.com/rigalite
SAFJ LED
LED Area Lighting for Hazardous Locations
Key Features:
1 Low profile and compact design
2 Wide distribution pattern with uplight
3 Field replaceable LED circuit boards and drivers with quick disconnects
4 Hinged mount for access to internal components
5 Clear or diffused lens options
6
6 No external fins 1
4
3
224
LED
SAFJ
LED Area Lighting for Hazardous Locations
1 BASIC LUMINAIRE
SAFJ LED
5 GLOBE & GUARD
LC = Low Profile Clear Globe
Class I, Division 2, Groups A, B, C & D LCG = Low Profile Clear Globe & Guard
Class II, Division 1 & 2, Groups E, F & G LPC = Low Profile Clear Polycarbonate
Class III LPCG = Low Profile Clear Polycarbonate & Guard
Simultaneous Presence LF = Low Profile Frosted Globe
Enclosed & Gasketed LFG = Low Profile Frosted Globe & Guard
Wet Locations LPF = Low Profile Frosted Polycarbonate Globe
UL1598A Marine Outside Type LPFG = Low Profile Frosted Polycarbonate Globe & Guard
UL 844 Hazardous Locations
UL 8750 LED Safety
NEMA 4X
6 MOUNTING STYLE
P = ¾" Pendant Mount
IP66 P1 = 1" Pendant Mount
CUL C = ¾" Ceiling Mount
ABS Type Approved C1 = 1" Ceiling Mount
W = ¾" Wall Mount
2 LAMP CURRENT / LAMP WATTAGE W1 = 1" Wall Mount
03 = 30 Watts S = 1-¼" 25°Stanchion Mount
06 = 50 Watts S1 = 1-½" 25°Stanchion Mount
L = 1-¼" 90°Stanchion Mount
L1 = 1-½" 90°Stanchion Mount
3 LAMP TYPE
L2 = LED 7 OPTIONS1
SS = Stainless Steel Inserts
FB1 = Single Fuse Block 2,3
4 DRIVER VOLTAGE
U = 120-277V 50/60HZ
FB2 = Double Fuse Block 2,3
SP = Surge Protector
N = 347/480V 60HZ
1 Consult factory for pricing.
2 Not available with universal driver unless incoming voltage is specified.
When installed, one fuse block is provided for 120 & 277V
and two fuse blocks are provided for 208, 220, 240, 347 and 480V.
Fuse not provided.
3 FB option not available for marine listed fixtures.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers
not listed in charts.
225
LED
SAFJ
LED Area Lighting for Hazardous Locations
226 226
LED
SAFJ
LED Area Lighting for Hazardous Locations
CEILING MOUNT
WALL MOUNT
227
LED
SAFJ
LED Area Lighting for Hazardous Locations
CEILING MOUNT
WALL MOUNT
228 228
LED
SAFJ
LED Area Lighting for Hazardous Locations
CEILING MOUNT
WALL MOUNT
229
LED
SAFJ
LED Area Lighting for Hazardous Locations
CEILING MOUNT
WALL MOUNT
230
LED
SAFJ
LED Area Lighting for Hazardous Locations
Certification Guide
Supply Wire
Lumens Class I, Div. 2, Class II, Div. 1 & 2
Total Simultaneous Suitable
Model Mount Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group E, F & G
Lumens Presence Temperature,
Watt A, B, C & D Class III
°C
SAFJ03L2LC P, C, W, S, L 30W 120V - 277V 50/60 Hz, 3059 109 74 4766 -20°C < Tamb < 50°C T3C T5 T3
90°C
SAFJ03L2LF P, C, W, S, L 30W 347V/480V 60Hz 2752 97 73 4778 -20°C < Tamb < 50°C T3C T5 T3
SAFJ03L2ULCXX
Candlepower Distribution Photometric Data
Deg. Parl.
0 1117
5 1065
10 1116
15 1152
20 1022
25 935
30 886
35 854
40 858
45 875
50 733
55 528
60 371
65 261
70 214
75 111
80 79
85 55
90 38
SAFJ03L2ULFXX
Candlepower Distribution Photometric Data
Deg. Parl.
0 849
5 847
10 841
15 828
20 806
25 775
30 738
35 692
40 640
45 850
50 518
55 454
60 393
65 332
70 267
75 205
80 145
85 106
90 79
231
LED
SAFJ
LED Area Lighting for Hazardous Locations
Certification Guide
Supply Wire
Lumens Class I, Div. 2, Class II, Div. 1 & 2
Total Simultaneous Suitable
Model Mount Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group E, F & G
Lumens Presence Temperature,
Watt A, B, C & D Class III
°C
SAFJ06L2LC P, C, W, S, L 50W 120V - 277V 50/60 Hz, 4806 100 74 4785 -20°C < Tamb < 55°C T3C T3A T3
90°C
SAFJ06L2LF P, C, W, S, L 50W 347V/480V 60Hz 4136 86 74 4734 -20°C < Tamb < 55°C T3C T3A T3
SAFJ06L2ULCXX
Candlepower Distribution Photometric Data
Deg. Parl.
0 1751
5 1680
10 1763
15 1815
20 1604
25 1460
30 1394
35 1355
40 1343
45 1385
50 1120
55 817
60 559
65 408
70 342
75 182
80 129
85 92
90 63
SAFJ06L2ULFXX
Candlepower Distribution Photometric Data
Deg. Parl.
0 1274
5 1271
10 1260
15 1243
20 1211
25 1165
30 1109
35 1043
40 969
45 880
50 786
55 687
60 592
65 496
70 395
75 299
80 217
85 155
90 115
232 232
LED
SAFJ
LED Area Lighting for Hazardous Locations
Certification Guide
Supply Wire
Lumens Class I, Div. 2, Class II, Div. 1 & 2
Total Simultaneous Suitable
Model Mount Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group E, F & G
Lumens Presence Temperature,
Watt A, B, C & D Class III
°C
SAFJ06L2LPC P, C, W, S, L 50W 120V - 277V 50/60 Hz, 4671 97 74 4804 -20°C < Tamb < 55°C T3C T3A T3
90°C
SAFJ06L2LPF P, C, W, S, L 50W 347V/480V 60Hz 3123 65 77 4571 -20°C < Tamb < 55°C T3C T3A T3
SAFJ06L2ULPCXX
Candlepower Distribution Photometric Data
Deg. Parl.
0 1610
5 1610
10 1566
15 1452
20 1431
25 1424
30 1332
35 1292
40 1342
45 1319
50 1049
55 839
60 639
65 504
70 280
75 171
80 125
85 91
90 62
SAFJ06L2ULPFXX
Candlepower Distribution Photometric Data
Deg. Parl.
0 1053
5 1048
10 1024
15 986
20 944
25 895
30 837
35 770
40 701
45 327
50 553
55 477
60 408
65 343
70 282
75 228
80 178
85 140
90 114
233 233
LED
SAFJ
LED Area Lighting for Hazardous Locations
Pendant mount with threaded glass 25° Stanchion mount with threaded
globe and guard. glass globe and guard.
234 234
LED
SAFJ
LED Area Lighting for Hazardous Locations
Accessories
Conduit Shipping
Outlet Catalog Shipping
Hub Size Weight Globes
Boxes No. Catalog No. Description Weight
(In.) (Lbs.) And Guards (Lbs.)
Rigid Pendant
Guard
JMP 3/4 3.0
Stainless Steel
JGU10 Wire Guard 1.0
Shipping
JMS1 1-1/2 5.0 SAFETY CABLE Catalog No. Weight
(Lbs.)
90° Stanchion Mount
JML 1-1/4 6.0
235
SAFR LED S
A
LED Area Lighting for Hazardous Locations
F
• Class I, Division 2, Groups A, B, C & D R
• Class II, Division 1 & 2, Groups E, F & G
• Class III L
• Class I, Zone 2, Groups IIA, IIB & IIC
E
D
• UL 8750 LED Safety
• UL 844 Hazardous Locations
• UL 1598 Wet Locations
• UL 1598A Marine Outside Type
• NEMA 4X
• IP66
• CUL
• ABS Type Approved
• Tested to LM 79 & LM 80
• US Patent # D637,339S
713.943.0340 | azz.com/rigalite
SAFR LED
LED Area Lighting for Hazardous Locations
Key Features:
1 Optics feature wide distribution pattern with uplight
2 Hinged mount for access to internal components
3 Field replaceable LED circuit boards and drivers with quick disconnects
4 Clear/ diffused lens options
5 Low profile
6 No external fins 3
2
5
4
1
178
LED
SAFR
LED Area Lighting for Hazardous Locations
SAFR-09-L2-U-LFG-C-XX
1 2 3 4 5 6 7
1 BASIC SAFR LUMINAIRE
Hazardous Location LED
5 GLOBE & GUARD
LC = Low Profile Clear Glass Globe Only
Class I, Division 2, Groups A, B, C & D LCG = Low Profile Clear Glass Globe & Guard
Class II, Division 1 & 2, Groups E, F & G LF = Low Profile Frosted Glass Globe Only
Class III LFG = Low Profile Frosted Glass Globe & Guard
Simultaneous Presence T5 = Type V (Symmetric)
Class I, Zone 2, Groups IIA, IIB & IIC Closed Bottom Glass Refractor
Enclosed and Gasketed T5G = Type V (Symmetric)
Wet Locations Closed Bottom Glass Refractor & Guard
NEMA 3R, 4X; IP66
UL 1598, UL1598A, UL844 & UL8750 6 MOUNTING STYLE
CUL P = 3/4" Pendant Mount
ABS Type Approved P1 = 1" Pendant Mount
C = 3/4" Ceiling Mount
C1 = 1" Ceiling Mount
2 LAMP CURRENT/LAMP WATTAGE
09 = 70 Watts W = 3/4" Wall Mount
11 = 96 Watts W1 = 1" Wall Mount
S = 1-1/4" 25° Stanchion Mount
S1 = 1-1/2" 25° Stanchion Mount
L = 1-1/4” 90° Stanchion Mount
3 LAMP TYPE
L2 = LED
L1 = 1-1/2” 90° Stanchion Mount
K = 3/4" Cone Top
K1 = 1" Cone Top
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
179
LED
SAFR
LED Area Lighting for Hazardous Locations
CEILING MOUNT
WALL MOUNT
180
LED
SAFR
LED Area Lighting for Hazardous Locations
CEILING MOUNT
WALL MOUNT
181
LED
SAFR
LED Area Lighting for Hazardous Locations
CEILING MOUNT
WALL MOUNT
182
LED
SAFR
LED Area Lighting for Hazardous Locations
Certification Guide
Supply Wire
Lumen Class I, Div. 2, Class II, Div. 1.
Total Simultaneous Suitable
Model Mount Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group E, F & G
Lumens Presence Temperature,
Watt A, B, C & D Class III
°C
SAFR09L2LC P, C, W, S, L, K 70W 6796 103 74 4755 -20°C < Tamb < 55°C T4 T6 T3B
120V - 277V 50/60 Hz,
SAFR09L2LF P, C, W, S, L, K 70W 6088 92 73 4760 -20°C < Tamb < 55°C T4 T6 T3B 90°C
347V/480V 60Hz
SAFR09L2T5 P, C, W, S, L, K 70W 5363 81 73 4740 -20°C < Tamb < 55°C T4 T6 T3B
SAFR09L2ULCXX
Candlepower Distribution Photometric Data
Deg. Parl.
0 3094
5 2784
10 2324
15 2170
20 2223
25 2160
30 1959
35 2076
40 2195
45 1754
50 1439
55 1209
60 916
65 644
70 436
75 350
80 144
85 106
90 57
SAFR09L2ULFXX
Candlepower Distribution Photometric Data
Deg. Parl.
0 1925
5 1919
10 1897
15 1859
20 1802
25 1723
30 1627
35 1512
40 1391
45 1258
50 1124
55 986
60 850
65 720
70 589
75 464
80 346
85 254
90 179
183
LED
SAFR
LED Area Lighting for Hazardous Locations
CEILING MOUNT
WALL MOUNT
184
LED
SAFR
LED Area Lighting for Hazardous Locations
CEILING MOUNT
WALL MOUNT
185
LED
SAFR
LED Area Lighting for Hazardous Locations
CEILING MOUNT
WALL MOUNT
186
LED
SAFR
LED Area Lighting for Hazardous Locations
Certification Guide
Supply Wire
Lumen Class I, Div. 2, Class II, Div. 1.
Total Simultaneous Suitable
Model Mount Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group E, F & G
Lumens Presence Temperature,
Watt A, B, C & D Class III
°C
SAFR11L2LC P, C, W, S, L, K 96W 9570 104 75 4798 -20°C < Tamb < 55°C T4A T6 T3C
120V - 277V 50/60 Hz,
SAFR11L2LF P, C, W, S, L, K 96W 8610 94 75 4807 -20°C < Tamb < 55°C T4A T6 T3C 90°C
347V/480V 60Hz
SAFR11L2T5 P, C, W, S, L, K 96W 5363 81 72 4625 -20°C < Tamb < 55°C T4A T6 T3C
SAFR11L2ULCXX
Candlepower Distribution Photometric Data
Deg. Parl.
0 3228
5 3276
10 3272
15 3344
20 3127
25 2966
30 2953
35 2920
40 2560
45 2327
50 2283
55 1819
60 1323
65 922
70 630
75 486
80 195
85 149
90 80
SAFR11L2ULFXX
Candlepower Distribution Photometric Data
Deg. Parl.
0 2682
5 2669
10 2634
15 2577
20 2496
25 2391
30 2268
35 2122
40 1965
45 1791
50 1612
55 1423
60 1233
65 1040
70 842
75 655
80 483
85 351
90 254
187
LED
SAFR
LED Area Lighting for Hazardous Locations
188
LED
SAFR
LED Area Lighting for Hazardous Locations
189
LED
SAFR
LED Area Lighting for Hazardous Locations
Accessories
Shipping Shipping
Conduit Hub
Outlet Boxes Catalog No. Weight Photo Cell Kit* Catalog No. Description Weight
Size (In.) (Lbs.) (Lbs.)
Rigid Pendant Automatic on-off
SMP 3/4 3.3 switch at
predetermined
light levels.
SMP1 1 3.3 SPH25-120 (120 volt only) .19
REQUIRES
SMW1 1 7.8 HLPC-208-277 FIELD .25
INSTALLATION.
(25 )
Stanchion Mount (25°)
SMS 1-1/4 5.9
Shipping
SAF/SAFR
Catalog No. Description Weight
Adapter Ring
SMS1 1-1/2 5.9 (Lbs.)
Adapter Ring
(90
Stanchion Mount (90°) UL listed as
SML 1-1/4 5.9 Luminaire Fitting
for use in Class
I Div. 2 Groups
SML1 1-1/2 5.9 A, B, C & D and
Marine. Mates
Refer to Certification Guide to determine suitability of individual fixture. RTXMV 3.25
with competitor
models APM2,
APM3, HPM2,
CM2, CM3,
TWM2, TWM3,
Guards / Safety Shipping JM5, PM5 and
Catalog No. Description QM25 mounts
Cable Weight (Lbs.)
Shipping
Stainless Steel Glass Globe Catalog No. Description Weight
Wire Guard for (Lbs.)
SXP25WG 1.5
Type 1, 3 & 5
Refractors
IES Type V light
SRT25GL distribution 6.6
Stainless Steel (asymmetrical)
Wire Guard for
SXP10WG Low Profile Clear 1.0
and Frosted
Low Profile Clear
Globes SGL10T 4.2
Globe
10128R 1.0
Low Profile
SFGL10T 4.2
Frosted Globe
190
SXPJ LED S
X
Explosionproof LED Area Lighting
P
• Class I, Division 1, Group C & D J
• Class II, Division 1, Groups E, F & G
• Class III
L
E
• Class I, Zone 1, Groups IIA & IIB
• Factory Sealed
• Paint Spray Booth (up to 40° C) D
• NEMA 4X
• IP66
• UL 844 Hazardous Locations
• UL 1598A Marine Outside Type
• UL 1598 Wet Locations
• UL 8750 LED Safety
• CUL
• Tested to LM79 & LM80
713.943.0340 | azz.com/rigalite
SXPJ LED
Explosionproof LED Area Lighting
Key Features:
1 Single-pin quick disconnect mount with double acme thread
2 Component access via single set screw
3 Field replaceable LED circuit boards and drivers with quick disconnects
4 Wireless electromechanical terminal block
1 2
SXPJ 11-L2-U-GG-P-XX
1 2 3 4 5 6 7
1 BASIC LUMINAIRE
5 GLOBE & GUARD
GG = Globe and Guard
SXPJ LED G = Globe only
Class I, Division 1, Groups C & D
Class II, Division 1, Groups E, F & G
Class III
6 MOUNTING STYLE
P = 3/4" Pendant Mount
Class I, Zone 1, Groups IIA & IIB P1 = 1" Pendant Mount
Factory Sealed C = 3/4" Ceiling Mount
UL 1598, UL 1598A, UL 8750 & UL 844 C1 = 1" Ceiling Mount
cUL W = 3/4" Wall Mount
NEMA Type 4X, IP66 W1 = 1" Wall Mount
Tested to LM79 & LM80 S = 1-1/4" Stanchion Mount4
Paint Spray Booth up to 40° C S1 = 1-1/2" Stanchion Mount4
T = Trunnion Mount4,5
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
SXPJ
Explosionproof LED Area Lighting
Pendant
SXPP Mount
BallastHOUSING
SXPJ Housing BallastHOUSING
SXPJ Housing
SXP25GL
Prismatic Glass Globe
Wire Guard
SXP25WG
SXPJ06L2UGXX
Certification Guide
Supply Wire
Lumens Class I, Div. 2, Class II, Div. 1. Shipping*
Total Simultaneous Suitable Hub
Model Mount Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group E, F & G Weight
Lumens Presence Temperature, Size
Watt A, B, C & D Class III (Lbs.)
°C
SXPJ06L2UGP 3/4 in. NPT
Pendant 50W 120V - 277V 50/60 Hz 5138 104 73 4896 -20°C < Tamb < 55°C T6 T6 T6 90°C 41.6
SXPJ06L2UGP1 1 in. NPT
SXPJ06L2UGC 3/4 in NPT
Ceiling 50W 120V - 277V 50/60 Hz 5138 104 73 4896 -20°C < Tamb < 55°C T6 T6 T6 90°C 43.5
SXPJ06L2UGC1 1 in. NPT
SXPJ09L2UGXX
Certification Guide
Supply Wire
Lumens Class I, Div. 2, Class II, Div. 1. Shipping*
Total Simultaneous Suitable Hub
Model Mount Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group E, F & G Weight
Lumens Presence Temperature, Size
Watt A, B, C & D Class III (Lbs.)
°C
SXPJ09L2UGP 3/4 in. NPT
Pendant 70W 120V - 277V 50/60 Hz 6313 97 72 4800 -20°C < Tamb < 55°C T6 T6 T6 90°C 41.6
SXPJ09L2UGP1 1 in. NPT
SXPJ09L2UGC 3/4 in NPT
Ceiling 70W 120V - 277V 50/60 Hz 6313 97 72 4800 -20°C < Tamb < 55°C T6 T6 T6 90°C 43.5
SXPJ09L2UGC1 1 in. NPT
SXPJ11L2UGXX
Certification Guide
Supply Wire
Lumens Class I, Div. 2, Class II, Div. 1. Shipping*
Total Simultaneous Suitable Hub
Model Mount Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group E, F & G Weight
Lumens Presence Temperature, Size
Watt A, B, C & D Class III (Lbs.)
°C
SXPJ11L2UGP 3/4 in. NPT
Pendant 96W 120V - 277V 50/60 Hz 8829 94 73 4863 -20°C < Tamb < 55°C T6 T6 T6 90°C 41.6
SXPJ11L2UGP1 1 in. NPT
SXPJ11L2UGC 3/4 in NPT
Ceiling 96W 120V - 277V 50/60 Hz 8829 94 73 4863 -20°C < Tamb < 55°C T6 T6 T6 90°C 43.5
SXPJ11L2UGC1 1 in. NPT
Shipping
Catalog Weight
Reflectors Description Number (Lbs.)
Standard Dome Reflector SR40D 3.00
Fiberglass Filled Polymeric
713.943.0340 | azz.com/rigalite
LFL FLOOD LIGHT
LED Flood Lighting for Harsh Environments
Key Features:
1 High-performance precision optics system
2 Driver access plate features stainless steel safety retention 1
chain and captive hardware
3 Field replaceable LED circuit boards and drivers with quick 4
disconnects
4 Approved for high-ambient applications, up to 65° C
5 Two (2) permanent safety cable retention points
2
5
LFL-20- L-U-T-76-XX
1 2 3 4 5 6 7
1 BASIC LUMINAIRE
LFL LED
5 MOUNTING
T = Trunnion
UL 1598 Wet Locations
UL 1598A Marine Outside Type
UL 8750 LED Safety
CSA C22.2
6 BEAM DISTRIBUTION
76 = 7H x 6V
IP66
NEMA 4X
7 OPTIONS2
EB = Eye Bolt
2 INPUT WATTS
07 = 70W
FB1 = Single Fuse Block1,3
FB2 = Double Fuse Block1,3
15 = 130W SP = Increased Surge Protection1
20 = 188W PC = Polycarbonate Lens
40 = 4000K CCT
3 LAMP TYPE
L = LED (5,000 CCT)
4 VOLTAGE/FREQUENCY
U = 120 thru 277V 50/60 HZ
N = 347/480V 60 HZ
12 = 120V 60 HZ1 1 Voltages for fuse block and surge protector.
22 = 220V 60 HZ1 2 Consult factory for pricing.
3 Not for Marine application.
24 = 240V 60 HZ1
27 = 277V 60 HZ1
34 = 347V 60 HZ1
48 = 480V 60 HZ1
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
LFL Flood Light
LED Flood Lighting for Harsh Environments
Certification Guide
Supply Wire Shipping*
Total Lumens Suitable
Model Mount Wattage Operating Voltage CRI CCT Ambient Temperature Weight
Lumens per Watt Temperature, (Lbs.)
°C
LFL07LUT76 Trunnion 70W 120V - 277V 50/60 Hz 6919 106 72 5108 -20°C < Tamb < 65°C 90°C 42
LFL07LNT76 Trunnion 70W 347V/480V 60Hz 6919 106 72 5108 -20°C < Tamb < 65°C 90°C 42
LFL15LUT76 Trunnion 130W 120V - 277V 50/60 Hz 13562 105 73 5088 -20°C < Tamb < 65°C 90°C 44
LFL15LNT76 Trunnion 130W 347V/480V 60Hz 13562 105 73 5088 -20°C < Tamb < 65°C 90°C 44
LHL20LUT76 Trunnion 188W 120V - 277V 50/60 Hz 19518 104 75 5218 -20°C < Tamb < 65°C 90°C 45
LHL20LNT76 Trunnion 188W 347V/480V 60Hz 19518 104 75 5218 -20°C < Tamb < 65°C 90°C 45
Photometric Data
LFL07LUT76 @ 40 Ft High; Tilt Angle = 45° LFL15LUT76 @ 40 Ft High; Tilt Angle = 45° LFL20LUT76 @ 40 Ft High; Tilt Angle = 45°
(ISOFOOTCANDLES) (ISOFOOTCANDLES) (ISOFOOTCANDLES)
LED
LFL Flood Light
LED Flood Lighting for Harsh Environments
Accessories
Catalog
Guard Number
Shipping
SAFETY CABLE Catalog No. Weight
(Lbs.)
86009
10128R 1.0
Catalog
Visor Number
86036P
LHFL FLOOD LIGHT L
LED Flood Lighting for Hazardous Locations
H
F
L
• Class I, Division 2, Groups A, B, C & D
• Class II, Divisions 1 & 2, Groups E, F & G
• Class III
• Zone 2, Groups IIA, IIB & IIC
• UL 844 Hazardous Locations
L
E
• UL 1598A Marine Outside Type
• UL 1598 Wet Locations
• UL 8750 LED Safety
• 65°C Ambient Temperature (Class I, Division 2) D
• 55°C Ambient Temperature (Class II & III)
• CAN/CSA C22.2 No. 250.0-08
• CAN/CSA C22.2 No. 137-M1981
• IECEx
Ex nA nC IIC T5 Gc
Ex tC IIIC T100°C Dc
-20°C ≤ Ta ≤ 55°C, IP66
Certificate: IECEx ETL 14.0003X
• ATEX
II 3 GD
Ex nA nC IIC T5 Gc
Ex tc IIIC T100°C Dc
-20°C ≤ Ta ≤ 55°C, IP66
Certificate: ITS14ATEX47946X
• DLC Listed
• Tested to LM79, LM80 Standards
• ABS Type Approved
• IP66
• NEMA 4X
• Tested to LM79, LM80 Standards
713.943.0340 | azz.com/rigalite
LHFL FLOOD LIGHT SERIES LED Flood Lighting for Hazardous Locations
Key Features:
1 High-performance precision optics system
2 Driver access plate features stainless steel safety retention
chain and captive hardware
3 Field replaceable LED circuit boards and drivers with quick 1
disconnects 4
4 Approved for high-ambient applications, up to 65° C
5 Two (2) permanent safety cable retention points
LHFL-20- L-U-T-76-XX
1 2 3 4 5 6 7
6 BEAM DISTRIBUTION
76 = 7H x 6V
2 INPUT WATTS
07 = 70W
15 = 130W 7 OPTIONS2
20 = 188W EB = Eye Bolt
FB1 = Single Fuse Block1,3
FB2 = Double Fuse Block1,3
3 LAMP TYPE
L = LED
SP = Surge Protector1
PC = Polycarbonate Lens (for Class I & II, Div. 2)
35 = 3500K CCT
40 = 4000K CCT
4 VOLTAGE/FREQUENCY
U = 120 thru 277V 50/60 HZ
56 = 5600K CCT
N = 347/480V 60 HZ
12 = 120V 60 HZ1
22 = 220V 60 HZ1
24 = 240V 60 HZ1
27 = 277V 60 HZ1
34 = 347V 60 HZ1
1 Voltages for fuse block and surge protector.
48 = 480V 60 HZ1 2 Consult factory for pricing.
3 Not for Marine application.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
LHFL Flood Light
LED Flood Lighting for Hazardous Locations
Certification Guide
Class
Class Supply Wire
Lumens II Div. 1 IECEX Shipping*
Total Ambient 1, Div. 2 Simul Suitable
Model Mount Wattage Operating Voltage per CRI CCT Group ATEX Weight
Lumens Temperature Group Presence Temperature,
Watt E, F & G Listed (Lbs.)
A, B, C & D °C
Class III
LHFL07LUT76 Trunnion 70W 120V - 277V 50/60 Hz 6919 106.05 71.7 5108 -20°C < Tamb < 55°C T5 T4A T4A - 90°C 42
LHFL07LNT76 Trunnion 70W 347V/480V 60Hz 6919 106.05 71.7 5108 -20°C < Tamb < 55°C T5 T4A T4A - 90°C 42
LHFL15LUT76 Trunnion 130W 120V - 277V 50/60 Hz 13562 104.51 72.6 5088 -20°C < Tamb < 55°C T5 T4A T4A - 90°C 44
LHFL15LNT76 Trunnion 130W 347V/480V 60Hz 13562 104.51 72.6 5088 -20°C < Tamb < 55°C T5 T4A T4A - 90°C 44
LHFL20LUT76 Trunnion 188W 120V - 277V 50/60 Hz 19518 104.09 75.13 5218 -20°C < Tamb < 55°C T5 T4A T4A - 90°C 45
LHFL20LNT76 Trunnion 188W 347V/480V 60Hz 19518 104.09 75.13 5218 -20°C < Tamb < 55°C T5 T4A T4A - 90°C 45
LHFL07LUT76 Trunnion 70W 120V - 277V 50/60 Hz 6919 106.05 71.7 5108 -20°C < Tamb < 65°C T5 - - - 105°C 42
LHFL07LNT76 Trunnion 70W 347V/480V 60Hz 6919 106.05 71.7 5108 -20°C < Tamb < 65°C T5 - - - 105°C 42
LHFL15LUT76 Trunnion 130W 120V - 277V 50/60 Hz 13562 104.51 72.6 5088 -20°C < Tamb < 65°C T5 - - - 105°C 44
LHFL15LNT76 Trunnion 130W 347V/480V 60Hz 13562 104.51 72.6 5088 -20°C < Tamb < 65°C T5 - - - 105°C 44
LHFL20LUT76 Trunnion 188W 120V - 277V 50/60 Hz 19518 104.09 75.13 5218 -20°C < Tamb < 65°C T5 - - - 105°C 45
LHFL20LNT76 Trunnion 188W 347V/480V 60Hz 19518 104.09 75.13 5218 -20°C < Tamb < 65°C T5 - - - 105°C 45
EXLHFL07LUT76 Trunnion 70W 120V - 277V 50/60 Hz 6919 106.05 71.7 5108 -20°C < Tamb < 55°C - - - Yes 105°C 42
EXLHFL15LUT76 Trunnion 130W 120V - 277V 50/60 Hz 1352 104.51 72.6 5088 -20°C < Tamb < 55°C - - - Yes 105°C 44
EXLHFL20LUT76 Trunnion 188W 120V - 277V 50/60 Hz 19518 104.09 75.13 5218 -20°C < Tamb < 55°C - - - Yes 105°C 45
Photometric Data
LHFL07LUT76 @ 40 Ft High; Tilt Angle = 45° LHFL15LUT76 @ 40 Ft High; Tilt Angle = 45° LHFL20LUT76 @ 40 Ft High; Tilt Angle = 45°
(ISOFOOTCANDLES) (ISOFOOTCANDLES) (ISOFOOTCANDLES)
LED
LHFL Flood Light
LED Flood Lighting for Hazardous Locations
Accessories
Catalog
Guard Number
Shipping
SAFETY CABLE Catalog No. Weight
(Lbs.)
86009
10128R 1.0
Catalog
Visor Number
86036P
LHFL HIGH/MID BAY L
H
LED Area Lighting for Hazardous Locations
F
• Class I, Division 2, Groups A, B, C & D
• Class II, Divisions 1 & 2, Groups E, F & G
L
• Class III
• Zone 2, Groups IIA, IIB & IIC L
• UL 844 Hazardous Locations
E
• UL 1598A Marine Outside Type
• UL 1598 Wet Locations
D
• UL 8750 LED Safety
• 65°C
C Ambient Temperature (Class I, Division 2)
• 55°C Ambient Temperature (Class II & III)
• CAN/CSA C22.2 No. 250.0-08
• CAN/CSA C22.2 No. 137-M1981
• Tested to LM79, LM80 Standards
• ABS Type Approved
• IP66
• NEMA 4X
713.943.0340 | azz.com/rigalite
LHFL HIGH/MID BAY
LED Area Lighting for Hazardous Locations
Key Features:
1 High-performance precision optics system
2 Field replaceable LED circuit boards and drivers with 1
quick disconnects
3 Approved for high-ambient applications, up to 65° C
4 Two (2) permanent safety cable retention points
3
5 Terminal Block
2
5
LHFL-20- L-U-P-76-XX
1 2 3 4 5 6 7
3 LAMP TYPE
L = LED (5000k CCT)
1 Voltages for fuse block and surge protector.
4
2 Consult factory for pricing.
VOLTAGE/FREQUENCY 3 Not for Marine application.
U = 120-277V 50/60 HZ
N = 347/480V 60 HZ
12 = 120V 60 HZ1
22 = 220V 60 HZ1
24 = 240V 60 HZ1
27 = 277V 60 HZ1
34 = 347V 60 HZ1
48 = 480V 60 HZ1
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
LHFL High/Mid Bay
LED Area Lighting for Hazardous Locations
Certification Guide
Supply Wire
Lumens Class I, Div. 2, Class II, Div. 1. Shipping*
Total Simultaneous Suitable
Model Mount Wattage Operating Voltage per CRI CCT Ambient Temperature Group Group E, F & G Weight
Lumens Presence Temperature,
Watt A, B, C & D Class III (Lbs.)
°C
LHFL07L Pendant 70W 6919 106.05 72 5108 -20°C < Tamb < 55°C T5 T4A T4A 90°C 38
120V - 277V 50/60 Hz,
LHFL15L Pendant 130W 13562 104.51 73 5088 -20°C < Tamb < 55°C T5 T4A T4A 90°C 42
347V/480V 60Hz
LHFL20L Pendant 188W 19518 104.09 75 5218 -20°C < Tamb < 55°C T5 T4A T4A 90°C 40
LHFL07L Pendant 70W 6919 106.05 72 5108 -20°C < Tamb < 65°C T5 - - 105°C 44
120V - 277V 50/60 Hz,
LHFL15L Pendant 130W 13562 104.51 73 5088 -20°C < Tamb < 65°C T5 - - 105°C 41
347V/480V 60Hz
LHFL20L Pendant 188W 19518 104.09 75 5218 -20°C < Tamb < 65°C T5 - - 105°C 45
Photometric Data
LHFL07LUP76XX LHFL15LUP76XX LHFL20LUP76XX
LED
LHFL High/Mid Bay
LED Area Lighting for Hazardous Locations
Accessories
Catalog
Guard Number
86009
LED
LHFL Series
Hazardous Locations • Cast Aluminum • Class I, Divsion 2 • Class II • Class III • UL 1598A • UL 844
Photometric Data
LFHL07LUT76 @ 40 Ft High; Tilt Angle = 45°
(ISOFOOTCANDLES) LHFL07LUT76XX
Total Lumens 6918.94
Input Power
65.24
(Watts)
Efficacy
106.05
(Lumens/Watt)
CRI 71.7
CCT 5108
Certification Guide
LED
LHFL Series
Hazardous Locations • Cast Aluminum • Class I, Divsion 2 • Class II • Class III • UL 1598A • UL 844
Accessories
Catalog Catalog
Guard Number Visor Number
86009 86036P
WFH LED W
F
High-Bay Lighting for Hazardous & Wet Locations
H
• Class I, Division 2, Groups A, B, C, & D
• Class II, Division 2, Groups F & G
L
• Class III
E
D
• UL 844 Hazardous Locations
• UL 1598 Wet Locations
• UL 8750 LED Safety
• NEMA 4X
• CUL Listed
• NSF Certified Food Equipment
• High Pressure Hose Down
• One Piece Welded Aluminum Construction
713.943.0340 | azz.com/rigalite
WFH
Industrial LED High-Bay Lighting for Hazardous Locations
Key Features:
Watershed design
Stainless steel captive hardware
Philips LED System driver and PCB
Welded aluminum lens frame with electrostatically applied baked on
epoxy finish
1 BASIC SERIES
WFH LED Fixture 5 LENS TYPE
CA = Clear Acrylic
Class I, Division 2, Groups A, B, C, & D
Class ll, Division 2, Groups F & G PA = Prismatic Acrylic
Class III CP = Clear Polycarbonate
UL 844 Hazardous Locations
UL 1598 Wet Locations
UL 8750 LED Safety 6 VOLTAGE/FREQUENCY
N = 347 thru 480V 50/60 HZ
NEMA 4X
CUL Listed U = 120 thru 277V 50/60 HZ
NSF Certified Food Equipment
Wash Down Rated
7 MOUNTING
2 LAMP CURRENT/LAMP WATTAGE DH = Dual Hub 1/2 in. NPT
150 = 148W LED SH = Single Hub 3/4 in. NPT
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
WFH
Industrial LED High-Bay Lighting for Hazardous Locations
Certification Guide
WFH150244XXU T5 T6 50° C
LED
WFH
Industrial LED High-Bay Lighting for Hazardous Locations
Accessories
713.943.0340 | azz.com/rigalite
WFHN SERIES
LED High-Bay Lighting for Heavy Hose-Down Environments
Stainless steel
captive hardware.
1 BASIC SERIES
WFHN LED Fixture 5 LENS TYPE
CA = Clear Acrylic
UL 1598 Wet Locations
UL 8750 LED Safety PA = Prismatic Acrylic
CUL Listed CP = Clear Polycarbonate
NSF Certified Food Equipment
Wash Down Rated
6 VOLTAGE/FREQUENCY
2 LAMP CURRENT/LAMP WATTAGE
150 = 148 Watt LED
N = 347 thru 480V 50/60 HZ
U = 120 thru 277V 50/60 HZ
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
WFHN Series
UL 1598 Wet Location • CUL • High Pressure Hose Down • NSF Certified
Accessories
Accessories
Key Features:
1 High lumen output in a compact luminaire
2 Rugged 5/32” thick housing 4
3 Glare-reducing frosted globe
4 Field replaceable LED circuit boards and drivers with quick
disconnects
5 Standard protective guard 2
• NEMA 3, 4 & 4X
• UL 1598 Wet Locations
• UL 1598A Marine Outside Type
• UL 8750 LED Safety
• CUL
• Copper Free Epoxy Coated Aluminum
• Enclosed and gasketed
• Heat Resistant frosted glass globe
• Suitable for indoor or outdoor use
• Suitable for hose-down
• Suitable for commercial and industrial uses only
• 3/4” NPT Hubs
• Dimmable (0-10V)
• Ambient Temperature Range: -20oC to +40oC
• Standard CCT - 4000K; See below for options
Ceiling
Mount
Wall
Mount
26 Watt LED
Accessories
Globe Guard
Thread Catalog Catalog
Type Color Description
Diameter Number Number
713.943.0340 | azz.com/rigalite
AVPH LED
LED Globe & Guard Lighting for Hazardous Locations
Key Features:
1 Compact luminaire with high lumen output
2 Rugged 5/32” thick housing
3 Glare-reducing frosted globe 4
4 Field replaceable LED circuit boards and drivers with quick
disconnects
5 Standard protective guard 2
1 BASIC LUMINAIRE
AVPH
5
Class I, Division 2, Groups A, B, C & D GUARD
UL 844 Hazardous Locations G = Guard (Required)
UL 1598A Marine Outside Type
UL 1598 Wet Locations 6
CUL
MOUNTING STYLE
NEMA 3, 4 & 4X
P = Pendant
W = Wall Mount with Box
2 C = Ceiling
LAMP WATTAGE AND TYPE
26L = 26 Watt LED (4000K CCT) 7
OPTIONS
3 30 = 3000K (CCT)
BALLAST VOLTAGE 35 = 3500K (CCT)
U = 120-277V 50/60 HZ 50 = 5000K (CCT)
4 GLOBE
HF = Heat Resistant Frosted Glass Globe
LED
AVPH
LED Globe & Guard Lighting for Hazardous Locations
Certification Guide
Supply Wire
Lumens Class I, Div. 2,
Total Suitable
Model Mount Wattage Operating Voltage per CRI CCT Ambient Temperature Group
Lumens Temperature,
Watt A, B, C & D
°C
AVPH26LUHFG P, C, W 26W 120V - 277V 50/60 Hz, 1746 67.7 82 3931 -20°C < Tamb < 40°C T4 90°C
Photometric Data
AVPH26-L-U-HF-G-P 4.1
Ceiling
Mount
AVPH26-L-U-HF-G-C 4.7
Wall
Mount
AVPH26-L-U-HF-G-W 5.4
Accessories
Globe Guard
Thread Catalog Catalog
Type Color Description
Diameter Number Number
713.943.0340 | azz.com/rigalite
BVP LED
Brass Lighting for Marine Environments
Key Features:
1 Compact luminaire with high lumen output
2 Rugged 5/32” thick housing 4
3 Glare reducing frosted globe
4 Field replaceable LED circuit boards and drivers with quick
disconnects
5 Standard protective guard 2
1
5
BVP 26L - U - HF - G - C - XX
1 2 3 4 5 6 7
1 BASIC LUMINAIRE
(i) BVP Marine
5 GUARD (Required)
G = Guard
UL 1598A Marine Outside Type
UL 1598 Wet Locations
UL 8750 LED Safety
CUL
6 MOUNTING STYLE
P = Pendant
NEMA 4X W = Wall Mount with Box
(ii) BVPD Wet Locations C = Ceiling
UL 1598 Wet Locations
UL 8750 LED Safety
7 OPTIONS
30 = 3000K (CCT)
35 = 3500K (CCT)
2 LAMP WATTAGE AND TYPE 50 = 50000 (CCT)
26L = 26 Watt LED E1 = 1/2” NPT Dead End (single hole in any location)
E2 = 3/4” NPT Dead End (single hole in any location)
C1 = 1/2” NPT Thru Feed (two holes on opposite sides)*
3 ALLAST VOLTAGE
B
C2 = 3/4” NPT Thru Feed (two holes on opposite sides)*
L1 = 1/2” NPT 90°(two holes at 90° angle)*
U = 120-277V 50/60 HZ
L2 = 3/4” NPT 90°(two holes at 90° angle)*
X1 = 1/2” NPT X (all four hubs drilled)*
4 GLOBE
X2 = 3/4” NPT X (all four hubs drilled)*
HF = Heat Resistant Frosted Glass Globe
* Ceiling and Wall Mount Only
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
BVP
Brass Lighting for Marine Environments
Certification Guide
Supply Wire
Lumen
Total Suitable
Model Mount Wattage Operating Voltage per CRI CCT Ambient Temperature
Lumens Temperature,
Watt
°C
BVP26LUHFG P, C, W 26W 120V - 277V 50/60 Hz, 1746 67.7 82 3931 -20°C < Tamb < 25°C 90°C
Ceiling
Mount
Wall
Mount
Accessories
Globe Guard
Thread Catalog Catalog
Type Color Description
Diameter Number Number
L
• Class III
• UL 1598A Marine Outside Type
• Temperature Class (T-Rating)-T6 E
• Patent No. 7,287,347 D
• IP65
• ETL Listed
713.943.0340 | azz.com/rigalite
HLEX LED SERIES
Hazardous Location Edge Lit LED Exit Sign
Key Features:
1 Emergency battery back-up integral to sign (no 2
additional enclosure required)
2 3-hour emergency operation
1
3 Optional battery back-up self-diagnostic feature
4 Field replaceable LED circuit boards and drivers 3 4
with quick disconnects
5 Edge-lit sign
HLEX-2-G-DT-WP-XX
1 2 3 4 5 6
1 BASIC SERIES
HLEX Explosion Proof LED Exit Light
4 VOLTAGE/FREQUENCY
DT = 120/277V 60 HZ
Class I, Division 2, Groups A, B, C, & D 24 = 220-240V 50/60 HZ
Class II, Division 2, Groups F & G Other voltages available- consult factory.
Class III
UL 1598A Marine Outside Type
IP65
ETL Listed
5 MOUNTING
WP = Wall/Pendant Mounting
Temperature Class (T-Rating)-T6 EB = End Bracket
2 NUMBER OF FACES
1 = Single Face
6 OPTIONS1
EM = Emergency Battery Backup
2 = Double Face SD = Self Diagnostics
X = Exit Legend in Other Languages
Language Must be Specified
3 LEGEND COLOR
R = Red
G = Green 1Consult factory for pricing.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
HLEX Series
Hazardous Location Edge Lit LED Exit Sign
A C
713.943.0340 | azz.com/rigalite
HLS LED SERIES
Edge Lit LED Sign for Hazardous Locations
Key Features:
1 Emergency battery back-up integral to sign (no
2
additional enclosure required)
2 3-hour emergency operation
3 Optional battery back-up self-diagnostic feature 1 3
4 Field replaceable LED circuit boards and drivers
with quick disconnects 4
5 Edge-lit sign
HLS-2-G-DT-WP-XX
1 2 3 4 5 6
1 BASIC SERIES
Hazardous Location LED Sign Light*
4 VOLTAGE/FREQUENCY
DT = 120/277V 60 HZ
*Customer must specify sign color and legend 24 = 220-240V 50/60 HZ
Class I, Division 2 Groups A, B, C & D Other voltages available- consult factory
Class II, Division 2, Groups F & G
Class III
UL 1598A Marine Outside Type 5 MOUNTING
WP = Wall/Pendant Mounting
IP65
ETL Listed EB = End Bracket
Temperature Class (T-Rating)-T6
6 OPTIONS1
2 NUMBER OF FACES
1 = Single Face
EM = Emergency Battery Backup
X = Specify Legend (Cannot Say EXIT)
2 = Double Face
3 LEGEND COLOR
A = Amber
1Consult factory for pricing.
B = Blue
R = Red
G = Green
X = Other (Contact Factory)
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
HLS Series
Edge Lit LED Sign for Hazardous Locations
A C
713.943.0340 | azz.com/rigalite
XPEL SERIES
Explosion Proof LED Emergency Light
Key Features: 1
1 High lumen spot lights (2) can be adjusted in horizontal
and vertical planes 5
2 Unit can power up to 2 (optional) remote spot lights
3 Field replaceable LED circuit boards and drivers with
quick disconnects
4 Emergency battery back-up integral to luminaire (no
additional enclosure required)
5 3-hour emergency operation 2
3 4
XPEL-U-2-2-M
1 2 3 4 5
1 BASIC SERIES
XPEL
3 INSTALLED HEADS
0 = None
Class I, Division 1, Groups C & D 1 = One Combinations Available
Class II, Division 1, Groups E, F & G 2 = Two Installed Remote Drivers
Class III
Class I , Zone 1, Groups IIA, IIB, 4 REMOTE HEADS1 2
1
0
1
1
1
UL 844, 1598, 8750 & 924 0 = None
UL 1598A Marine Outside Type (Salt Water) 1 = One 0 2 1
USCG Regulation 46 Sub Part 111.75-15(e) & 112.43 2 = Two 2 2 2
CUL 3 = Three
1 3 2
IP65 4 = Four
NEMA 4X 0 4 2
Suitable for Wet Locations 5 OPTIONS 2
provided with extra LED driver. Remote heads can only be wired
to the emergency fixtures with remote head option. LED heads are
furnished with 1/2"-14 NPT male hub, must be installed on suitably
listed explosion proof junction box not provided by RAL.
2
Consult factory for pricing.
Certification Guide
Class II, Division 1 Simultaneous
XPEL Series Emergency Ambient Temperature Class I, Division 1 UL 1598A
Groups E, F & G Presence CUL
Light Range Groups C & D Marine
Class III Class I & II
XPEL +10° C to +55° C T6 T6 T6 Yes Yes
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
XPEL Series
Explosion Proof • UL 844 • UL 1598 • UL 8750 • UL 924 • UL 1598A Marine Outside Type • CUL
Photometric Data
XPEL LED head with medium beam optics:
Total Lumens per Head 420.78 Average Initial Footcandles at the Floor 1.49
Output Power per Head 4.83 Maximum Initial Footcandles at the Floor 2.80
Efficacy (Lumens/Watts) 87.12 Minimum Initial Footcandles at the Floor 0.50
CRI 72 Maximum to Minimum Ratio 5.60
CCT 5672
LED
XPEL Series
Explosion Proof • UL 844 • UL 1598 • UL 8750 • UL 924 • UL 1598A Marine Outside Type • CUL
713.943.0340 | azz.com/rigalite
XPEH LED
Explosion Proof LED Emergency Light & Exit Sign
1
Key Features:
1 Two high lumen spot lights can be adjusted in horizontal
6
and vertical planes
2 Independent battery backup system for exit signs and 2 3
spotlights 4
3 Unit can power up to two optional remote spot lights
4 Field replaceable LED circuit boards and drivers with
quick disconnects
5 Emergency battery back-up integral to sign (no 5
additional enclosure required)
6 3-hour emergency operation
7 Edge-lit sign
XPEH-1-R-DT-2-2-XX
1 2 3 4 5 6 7
1 BASIC LUMINAIRE
XPEH LED
4 VOLTAGE / FREQUENCY
DT = 120/277V 60HZ
Class I, Division 1, Groups C & D 24 = 220-240V 50HZ
Class II, Division 1, Groups E, F & G
Class III 5 INSTALLED HEADS
0 = None
Combinations Available
Class I , Zone 1, Groups IIA, IIB,
UL 844, 1598, 8750, 924 1 = One Installed Remote Drivers
UL 1598A Marine Outside Type (Salt Water) 2 = Two 2 0 1
USCG Regulation 46 CFR Subparts 111.75-15 (e) & 112.43 1 1 1
CUL 6 REMOTE HEADS1
0 = None
0 2 1
IP65
1 = One 2 2 2
NEMA 4X
Suitable for Wet Locations 2 = Two 1 3 2
3 = Three 0 4 2
2 NUMBER OF FACES 4 = Four
1 = Single Face
2 = Double Face 7 OPTIONS2
N = Narrow Beam Optics
3 LEGEND COLOR
R = Red
W = Wide Beam Optics
X = EXIT Legend in other languages
G = Green Language must be specified
provided with extra LED driver. Remote heads can only be wired
to the emergency fixtures with remote head option. LED heads are
furnished with 1/2"-14 NPT male hub, must be installed on suitably
listed explosion proof junction box not provided by RAL.
Maximum Input Power 2Consult Factory for pricing.
XPEH Emergency Light with:
Red Exit Sign & 2 LED heads - 6.5 W Maximum Output Data
Red Exit Sign & 4 LED heads - 10.5 W Each Remote Head:
Green Exit Sign & 2 LED heads - 7 W Voltage: 22V DC. max.
Green Exit Sign & 4 LED heads - 11W Current: 0.225 A (225mA)
Max. Power: 5 W
Certification Guide
Class II, Division 1 Simultaneous
XPEH Series Emergency Ambient Temperature Class I, Division 1 UL 1598A
Groups E, F & G Presence CUL
Combo with: Range Groups C & D Marine
Class III Class I & II
Green Exit Sign 10° C to 35° C T6 T6 T6 Yes Yes
Red Exit Sign 10° C to 45° C T6 T6 T6 Yes Yes
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
LED
XPEH
Explosion Proof LED Emergency Light & Exit Sign
Photometric Data
XPEH LED head with medium beam optics:
Total Lumens per Head 420.78 Average Initial Footcandles at the Floor 1.49
Output Watts per Head 4.83 Maximum Initial Footcandles at the Floor 2.80
Efficacy (Lumens/Watts) 87.12 Minimum Initial Footcandles at the Floor 0.50
CRI 72 Maximum to Minimum Ratio 5.60
CCT 5672
LED
XPEH
Explosion Proof LED Emergency Light & Exit Sign
713.943.0340 | azz.com/rigalite
XPEX SERIES
Explosion Proof LED Edge Lit Exit Light
Key Features:
1 Emergency battery back-up integral to sign (no
additional enclosure required) 2
2 3-hour emergency operation
1
3 Optional battery back-up self-diagnostic feature
4 Field replaceable LED circuit boards and drivers 3 4
with quick disconnects
5 Edge-lit sign
XPEX-2-G-DT-WP-XX
1 2 3 4 5 6
1 BASIC SERIES
XPEX Explosion Proof LED Exit Light
3 LEGEND COLOR
R = Red
Class I, Division 1, Groups C, & D G = Green
Class II, Division 1 & 2, Groups E, F & G
Class III
Class I , Zone 1, Groups IIA, IIB, 4 VOLTAGE / FREQUENCY
Zone 2, Groups IIA, IIB + H2 & IIC DT = 120/277V 60HZ
Marine Outside Type 24 = 220-240V 50/60HZ
UL 1598A, 8750, 844 & 924 Other voltages available - consult factory
IP65
Temperature Class (T-Rating)-T6
5 MOUNTING
WP = Wall/Pendant Mounting
2 NUMBER OF FACES EB = End Bracket
1 = Single Face
2 = Double Face 6 OPTIONS1
EM = Emergency Battery Backup
EU = Green Running Man Exit Legend
SD = Self Diagnostics
X = Exit Legend in Other Languages
Language Must Be Specified
1Consult factory for pricing.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
XPEX Series
Explosion Proof • UL 844 • UL 924 • UL 1598A Marine Outside Type • Factory Sealed
A C
713.943.0340 | azz.com/rigalite
XPS LED SERIES
Explosion Proof Edge Lit LED Multipurpose Sign
Key Features:
1 Emergency battery back-up integral to sign (no
additional enclosure required) 2
2 3-hour emergency operation
3 Optional battery back-up self-diagnostic feature
4 Field replaceable LED circuit boards and drivers 1 3
with quick disconnects
5 Edge-lit sign 4
XPS-2-G-DT-WP-XX
1 2 3 4 5 6
1 BASIC SERIES
XPS Explosion Proof LED Sign Light*
3 LEGEND COLOR
A = Amber
*Customer must specify sign color and legend B = Blue
Class I, Division 1, Groups C, & D R = Red
Class II, Division 1, Groups E, F & G G = Green
Class III X = Other (Contact Factory)
Class I , Zone 1, Groups IIA, IIB,
Zone 2, Groups IIA, IIB + H2 & IIC
Marine Outside Type 4 VOLTAGE / FREQUENCY
DT = 120/277V 60HZ
UL 1598A, 8750, 844 & 924
IP65 24 = 220-240V 50/60HZ
Temperature Class (T-Rating)-T6 Other voltages available - consult factory
6 OPTIONS1
EM = Emergency Battery Backup
X = Specify Legend (Cannot Say EXIT)
1Consult factory for pricing.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
XPS Series
Explosion Proof • UL 844 • UL 924 • UL 1598A Marine Outside Type • Factory Sealed
A C
713.943.0340 | azz.com/rigalite
MAR SERIES
Fluorescent Lighting for Hazardous Locations
Each MAR Series fixture is individually tested for functional and dielectrical strength at the factory to assure quality
and reliability. This heavy-duty fixture arrives completely assembled.
Extruded aluminum
lens frame for greater
strength.
MAR 800-2-A-XX
1 2 3 4 5
1 BASIC SERIES 4 VOLTAGE/FREQUENCY
MAR Fluorescent Fixture
E = 12V DC (425mA only)
Class I, Division 2, Groups A, B, C & D F = 24V DC (425mA only)
UL 844 Hazardous Location G = 32V DC (425mA only)
UL 1598A Marine Outside Type H = 347V 60 HZ
CSA Certified U = 120 thru 277V 50/60 HZ
Zone 2, Groups IIA, IIB & IIC
55°C Ambient Temperature Rating
IP66
5 OPTIONS1
TW = End Mounting/Thru Wire
2 LAMP CURRENT/LAMP WATTAGE Cable Installations Only
800 = 800mA, 60/35 Watt F = Single Fuse2
430 = 430mA, 34/20 Watt (export only) R = Radio Interference Filter
425 = 425mA, 40/20 Watt (Slimline) L = Lamps
265 = 265mA, 32/17 Watt (T8 Lamps) EM = Emergency Battery Backup (Max 50°C)3
TM = Tempered Glass
3 NOMINAL FIXTURE LENGTH HL = Hi-Lumen Ballast (T8 Only)
2 = 2 Foot EB = Eye Bolt Only
4 = 4 Foot SC = Safety Cable with Eye Bolt
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
Options
FLUORESCENT
MAR Series
Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Wet Locations
Certification Guide
Ambient Temperature Class I, Division 2 Supply Wire Suitable
Model oC Groups A, B, C & D Temperature oC
MAR 430, 800 55 T4A 90
MAR 425 55 T4A 90
MAR 265 55 T4A 90
Accessories
713.943.0340 | azz.com/rigalite
MAR2 SERIES
Fluorescent Lighting for Hazardous Locations
Each MAR 2 Series fixture is individually tested for functional and dielectrical strength at the factory to assure
quality and reliability. This heavy-duty fixture arrives completely assembled.
MAR2 800-2-A-XX
1 2 3 4 5
1 BASIC SERIES 4 VOLTAGE/FREQUENCY
MAR2 Fluorescent Fixture E = 12V DC (425mA Only)
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
FLUORESCENT
MAR2 Series
Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Wet Locations
Certification Guide
Ambient Temperature Class I, Division 2 Supply Wire Suitable
Model oC Groups A, B, C & D Temperature oC
MAR 430, 800 55 T4A 90
MAR 425 55 T4A 90
MAR 265 55 T4A 90
Accessories
713.943.0340 | azz.com/rigalite
MHD2/MHDO SERIES
Marine Heavy Duty Outdoor Non-Metallic Fluorescent
Non-metallic, glass
reinforced polyester housing.
Captive stainless
steel latches.
Housing:
• Corrosion free high impact fiberglass Diffuser:
housing • High Impact DR acrylic diffuser-
• Water tight gasket attached to the lens polycarbonate option available
• Captive SS latches Mounting:
• Heavy duty aluminum ballast tray • Stainless steel mounting brackets
• 3/4 in. NPT aluminum conduit hubs standard
• 4 ft. models with 1, 2, or 3 lamp versions
140
FLUORESCENT
MHD2/MHDO Series
Hazardous Locations • Class 1, Divison 2 • Non-Metallic • UL 1598A Marine Outside Type • UL 844 • UL 924 • CUL
4 NUMBER OF LAMPS
1 = 1 Lamp
2 = 2 Lamps
3 = 3 Lamps2
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
Options
FLUORESCENT
MHD2/MHDO Series
Hazardous Locations • Class 1, Divison 2 • Non-Metallic • UL 1598A Marine Outside Type • UL 844 • UL 924 • CUL
A D
B
C
E
Certification Guide
Class II, Div. 2, Supply Wire
Ambient Temperature Class I, Div. 2
Model Groups F & G, Suitable Temp
(°C) Groups A, B, C & D
Class III °C
MHD2 425, 430, 800 40 T4 T3C 90
MHD2 265 40 T4 T3C 90
MHD2 265 55 T4A - 90
MHD2 T5, T5HO 40 T4 T3C 90
MHD2 T5, T5HO 55 T3C - 90
MHD2 T8HO 40 T4 T3C 90
MHD2 T8HO 55 T4A - 90
FLUORESCENT
MHD2/MHDO Series
Hazardous Locations • Class 1, Divison 2 • Non-Metallic • UL 1598A Marine Outside Type • UL 844 • UL 924 • CUL
5 1094 1092 1092 1088 1090 Room Cavity Ratio Effective Floor Cavity Reflectance 20%
RCR
15 1057 1063 1077 1090 1098
0 .93 .93 .93 .84 .84 .84 .74 .74 .74
25 978 1003 1040 1085 1103 1 .76 .71 .66 .68 .64 .61 .59 .57 .54
35 867 912 991 1066 1093 2 .64 .57 .51 .57 .52 .47 .49 .46 .43
45 718 789 906 1010 1043 3 .55 .47 .41 .49 .43 .38 .42 .38 .34
55 531 632 780 899 932 4 .48 .39 .33 .43 .36 .31 .37 .32 .28
65 316 440 610 747 781 5 .42 .34 .28 .38 .31 .26 .33 .28 .24
75 140 268 463 598 631 6 .37 .29 .23 .34 .27 .22 .29 .24 .20
85 38 147 314 432 458 7 .33 .26 .20 .30 .24 .19 .26 .21 .18
8 .30 .23 .17 .27 .21 .17 .24 .19 .15
90 16 102 261 365 402
9 .27 .20 .15 .25 .19 .15 .22 .17 .13
95 16 78 230 331 373 10 .25 .18 .14 .23 .17 .13 .20 .15 .12
105 10 41 159 249 292
115 4 16 70 134 172
125 0 2 20 37 57
135 0 0 7 14 16
145 0 0 0 5 8
155 0 0 0 0 1
165 0 0 0 0 0
Accessories
713.943.0340 | azz.com/rigalite
MHDA SERIES
Marine Heavy Duty Fluorescent Luminaire for Hazardous Locations
Captive stainless
steel latches.
Housing: Diffuser:
• Corrosion resistant aluminum housing • High Impact DR acrylic diffuser-
• Water tight gasket attached to the lens polycarbonate option available
• Captive SS latches Mounting:
• Heavy duty aluminum ballast tray • Stainless steel mounting brackets
• 3/4 in. NPT aluminum conduit hubs standard
FLUORESCENT
MHDA Series
Hazardous Locations • Class 1, Divison 2 • Class II, Divison 2 • Class III • UL 1598A Marine Outside Type • UL 844
MHDA 265-4 -X-U-XX
1 2 3 4 5 6
1 BASIC SERIES
MHDA Aluminum Fluorescent
4 NUMBER OF LAMPS
2 = Two Lamp
Class I, Division 2, Groups A, B, C and D 3 = Three Lamp (T8, T5 & T5HO Only)
Class II, Division 2 Groups F & G
Class III
UL 844 Hazardous Locations
UL1598A Marine Outside Type 5 VOLTAGE/FREQUENCY
U = 120 thru 277V 50/60 HZ
CSA C22.2 #137; C22.2 #213
N = 347 thru 480V 50/60 HZ
CUL
H = 347V 60 HZ
55° C Ambient Temperature
IP66
6 OPTIONS1
2 LAMP CURRENT/LAMP WATTAGE P = Polycarbonate Lens
800 = 800mA, 60 Watt F = Single Fuse2
430 = 430mA, 34 Watt (export only) FB = Fuse Block2
425 = 425mA, 40 Watt (Slimline) TB = Terminal Block
265 = 265mA, 32 Watt T8 TW = Thru Wire
T8HO = T8HO, 44 Watt Cable Installations Only
T5 = T5, 28 Watt PM = Pendant Mount
T5HO = T5HO, 54 Watt EM = Emergency Battery Backup
EM NON = Non-Hazardous Emergency
3 NOMINAL FIXTURE LENGTH 1 Consult factory for pricing.
4 = Four Foot 2 Fuse option not available for marine listed fixtures.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
Options
FLUORESCENT
MHDA Series
Hazardous Locations • Class 1, Divison 2 • Class II, Divison 2 • Class III • UL 1598A Marine Outside Type • UL 844
Certification Guide
Ambient Class I, Div. 2 Groups Class II, Div. 2, Groups Supply Wire Suitable
Model
Temperature (°C) A, B, C & D F & G, Class III Temp °C
MHDA 265 40 T4 T3C 90
MHDA 265 55 T4A - 90
MHDA T5, T5HO 40 T4 T3C 90
MHDA T5, T5HO 55 T3C - 90
MHDA T8HO 40 T4 T3C 90
MHDA T8HO 55 T4A - 90
FLUORESCENT
MHDA Series
Hazardous Locations • Class 1, Divison 2 • Class II, Divison 2 • Class III • UL 1598A Marine Outside Type • UL 844
A D
B
C
E
Accessories
5 1094 1092 1092 1088 1090 Room Cavity Ratio Effective Floor Cavity Reflectance 20%
RCR
15 1057 1063 1077 1090 1098
0 .93 .93 .93 .84 .84 .84 .74 .74 .74
25 978 1003 1040 1085 1103 1 .76 .71 .66 .68 .64 .61 .59 .57 .54
35 867 912 991 1066 1093 2 .64 .57 .51 .57 .52 .47 .49 .46 .43
45 718 789 906 1010 1043 3 .55 .47 .41 .49 .43 .38 .42 .38 .34
55 531 632 780 899 932 4 .48 .39 .33 .43 .36 .31 .37 .32 .28
65 316 440 610 747 781 5 .42 .34 .28 .38 .31 .26 .33 .28 .24
75 140 268 463 598 631 6 .37 .29 .23 .34 .27 .22 .29 .24 .20
85 38 147 314 432 458 7 .33 .26 .20 .30 .24 .19 .26 .21 .18
8 .30 .23 .17 .27 .21 .17 .24 .19 .15
90 16 102 261 365 402
9 .27 .20 .15 .25 .19 .15 .22 .17 .13
95 16 78 230 331 373 10 .25 .18 .14 .23 .17 .13 .20 .15 .12
105 10 41 159 249 292
115 4 16 70 134 172
125 0 2 20 37 57
135 0 0 7 14 16
145 0 0 0 5 8
155 0 0 0 0 1
165 0 0 0 0 0
713.943.0340 | azz.com/rigalite
MHDS SERIES
Marine Heavy Duty Fluorescent Luminaire for Hazardous Locations
Captive stainless
steel latches.
Housing:
• Corrosion resistant stainless steel Diffuser:
housing • High Impact DR acrylic diffuser-
• Water tight gasket attached to the lens polycarbonate option available
• Captive SS latches Mounting:
• Heavy duty aluminum ballast tray • Stainless steel mounting brackets
• 3/4 in. NPT aluminum conduit hubs standard
166
FLUORESCENT
MHDS Series
Hazardous Locations • Class 1, Divison 2 • Class II, Divison 2 • Class III • UL 1598A Marine Outside Type • UL 844
MHDS 265-4 -X-U-XX
1 2 3 4 5 6
1 BASIC SERIES
MHDS Stainless Steel Fluorescent
4 NUMBER OF LAMPS
2 = Two Lamp
Class I, Division 2, Groups A, B, C and D 3 = Three Lamp (T8, T5 & T5HO Only)
Class II, Division 2 Groups F & G
Class III
UL 844 Hazardous Locations
UL1598A Marine Outside Type 5 VOLTAGE/FREQUENCY
U = 120 thru 277V 50/60HZ
CSA C22.2 #137; C22.2 #213
N = 347 thru 480V 50/60HZ
CUL
H = 347V 60HZ
55° C Ambient Temperature
IP66
6 OPTIONS1
P = Polycarbonate Lens
2 LAMP CURRENT/LAMP WATTAGE F = Single Fuse2
800 = 800mA, 60 Watt FB = Fuse Block2
430 = 430mA, 34 Watt (export only) TB = Terminal Block
425 = 425mA, 40 Watt (Slimline) TW = Thru Wire
265 = 265mA, 32 Watt T8 Cable Installations Only
T8HO = T8HO, 44 Watt PM = Pendant Mount
T5 = T5, 28 Watt EM = Emergency Battery Backup
T5HO = T5HO, 54 Watt EM NON = Non-Hazardous Emergency
316 = SS316L Housing
3 NOMINAL FIXTURE LENGTH
4 = Four Foot 1 Consult factory for pricing.
2 Fuse option not available for marine listed fixtures.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
Options
FLUORESCENT
MHDS Series
Hazardous Locations • Class 1, Divison 2 • Class II, Divison 2 • Class III • UL 1598A Marine Outside Type • UL 844
Certification Guide
Ambient
Class I, Div. 2 Groups Class II, Div. 2, Groups Supply Wire Suitable
Model Temperature
A, B, C & D F & G, Class III Temp °C
(°C)
MHDS 265 40 T4 T3C 90
MHDS 265 55 T4A - 90
MHDS T5, T5HO 40 T4 T3C 90
MHDS T5, T5HO 55 T3C - 90
MHDS T8HO 40 T4 T3C 90
MHDS T8HO 55 T4A - 90
FLUORESCENT
MHDS Series
Hazardous Locations • Class 1, Divison 2 • Class II, Divison 2 • Class III • UL 1598A Marine Outside Type • UL 844
A D
B
C
E
Accessories
5 1094 1092 1092 1088 1090 Room Cavity Ratio Effective Floor Cavity Reflectance 20%
RCR
15 1057 1063 1077 1090 1098
0 .93 .93 .93 .84 .84 .84 .74 .74 .74
25 978 1003 1040 1085 1103 1 .76 .71 .66 .68 .64 .61 .59 .57 .54
35 867 912 991 1066 1093 2 .64 .57 .51 .57 .52 .47 .49 .46 .43
45 718 789 906 1010 1043 3 .55 .47 .41 .49 .43 .38 .42 .38 .34
55 531 632 780 899 932 4 .48 .39 .33 .43 .36 .31 .37 .32 .28
65 316 440 610 747 781 5 .42 .34 .28 .38 .31 .26 .33 .28 .24
75 140 268 463 598 631 6 .37 .29 .23 .34 .27 .22 .29 .24 .20
85 38 147 314 432 458 7 .33 .26 .20 .30 .24 .19 .26 .21 .18
8 .30 .23 .17 .27 .21 .17 .24 .19 .15
90 16 102 261 365 402
9 .27 .20 .15 .25 .19 .15 .22 .17 .13
95 16 78 230 331 373 10 .25 .18 .14 .23 .17 .13 .20 .15 .12
105 10 41 159 249 292
115 4 16 70 134 172
125 0 2 20 37 57
135 0 0 7 14 16
145 0 0 0 5 8
155 0 0 0 0 1
165 0 0 0 0 0
713.943.0340 | azz.com/rigalite
RSS SERIES
Stainless Steel Fluorescent Lighting for Hazardous Locations
Each RSS Series fixture is individually tested for functional and dielectrical strength at the factory
to ensure quality and reliability.
Stainless steel
safety tab
Durable seam welded type 304
stainless steel housing standard.
Type 316 stainless steel available
as an option.
Stainless steel
Stainless steel cam action
mounting
latches for maximum strength
brackets included.
and durability. Captive
stainless steel latches on one
side act as hinge for added
convenience.
Heavy-duty stainless
steel lens frame for
easy lens change-out.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
FLUORESCENT
RSS Series
Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A Marine Outside Type • CUL
Options
• Class I, Division 2, Groups A, B, C and D
• UL 844 Hazardous Locations
• UL 1598A Marine Outside Type
• Stainless Steel
• CUL
• Wet Locations
• IP66
Hub Size
Description (inches) Voltage Catalog Number
32 Watt, Instant Start 3/4 120-277V 50/60HZ RSS265-4-U
Medium Bi-Pin, T8, 265mA, 48"
Certification Guide
OPERATING TEMPERATURE CODE
RSS SERIES CLASS I, DIVISION 2 RATED AMBIENT
GROUPS A, B, C & D TEMPERATURE
Accessories
713.943.0340 | azz.com/rigalite 9
XP SERIES
Fluorescent Lighting for Hazardous and Hostile Locations
Each XP Series fixture is individually tested for functional and dielectrical strength at the factory to assure quality
and reliability and arrives assembled including reflectors, reducing installation time and cost.
XP Series heavy duty fixtures are suitable for installation in environments where fire or explosion hazards may exist due to
flammable gases or vapors, flammable liquids, combustible dust, ignitable fibers or flyings, as defined by ANSI/NFPA 70/NEC
Article 500. These fixtures are also suitable for installation in wet locations and marine environments where equipment is
subjected to salt water spray, either indoor or outdoor.
FLUORESCENT
XP Series
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
FLUORESCENT
XP XPSeries
Series
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
Certification Guide
CLASS II
CLASS l DIVISION 1 SIMULTANEOUS
AMBIENT DIVISION 1 GROUPS E, F & G PRESENCE UL
XP SERIES °C GROUPS C & D CLASS III CLASS I & II 1598A CSA
XP2652L 55 T6 T6 T6 YES YES
XP2702L 55 T6 T6 T6 YES NO
XP2703L 40 T6 T6 T6 YES NO
XP2704L 55 T6 T6 T6 YES NO
XP4252L 55 T4A T4A T4A YES YES
XP4253L 40 T4A T4A T4A YES YES
XP4254L 55 T4A T4A T4A YES YES
XP4302L 55 T6 T6 T6 YES YES
XP4303L 40 T6 T6 T6 YES YES
XP4304L 55 T6 T6 T6 YES YES
XP8002L 55 T6 T6 T6 YES YES
XP8003L 40 T6 T6 T6 YES YES
XP8004L 55 T6 T6 T6 YES YES
XP15002L 55 T6 T6 T6 YES YES
XP15003L 40 T6 T6 T6 YES YES
XP15004L 55 T6 T6 T6 YES YES
XPT5HO2L 55 T6 T6 T6 YES YES
XPT5HO3L 40 T6 T6 T6 YES YES
XPT5HO4L 55 T6 T6 T6 YES YES
FLUORESCENT
XP Series
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
2-Lamp XP
• Class I, Division 1, Groups C and D; Class I, Division 2, Groups C and D; Class II, Division 1 and 2,
Groups E, F and G; Class III
• UL 844 for Hazardous Locations and use inside paint spray booths and rooms. Also meets requirements
for NFPA Standard 33 and NEC Article 516
• Simultaneous Presence
• UL 1598A Marine Outside Type
• CSA Approved
• Class I, Zone 1, Groups IIA and IIB
• Class I, Zone 2, Groups IIA, IIB and IIC
• Seismic tested by Structural Dynamics Research Corporation (full scale fragility qualification) tested
in frequencies of 1 to 31.6 Hertz in 3-plane axis with maximum G force of 18.67 achieved
• NEMA 3, 4X, 7CD, 9EFG
(Lamps included)
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
Coefficients of Utilization
% Effective Ceiling Cavity
Reflectance 80 70 50 30 10 0
lcc
% Wall Reflectance
lw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR 20% Effective Floor Cavity Reflectance
0 .85 .85 .85 .85 .83 .83 .83 .83 .79 .79 .79 .75 .75 .75 .72 .72 .72 .71
1 .74 .70 .65 .62 .72 .68 .64 .60 .64 .61 .58 .61 .59 .56 .59 .56 .54 .53
2 .66 .59 .53 .47 .64 .57 .52 .47 .54 .50 .45 .52 .48 .44 .49 .46 .43 .41
3 .60 .50 .43 .38 .58 .49 .43 .37 .47 .41 .36 44 .40 .36 .42 .38 .35 .33
4 .54 .44 .36 .31 .52 .43 .36 .30 .41 .35 .30 .39 .34 .29 .37 .33 .29 .27
5 .49 .39 .31 .26 .47 .38 .31 .26 .36 .30 .25 .34 .29 .25 .33 .28 .24 .23
6 .45 .34 .27 .22 .44 .34 .27 .22 .32 .26 .21 .31 .25 .21 .29 .25 .21 .19
7 .42 .31 .24 .19 .40 .30 .23 .19 .29 .23 .18 .28 .22 .18 .27 .22 .18 .16
8 .38 .28 .21 .16 .37 .27 .21 .16 .26 .20 .16 .25 .20 .16 .24 .19 .16 .14
9 .36 .25 .19 .14 .35 .25 .19 .15 .24 .18 .14 .23 .18 .14 .22 .17 .14 .12
10 .33 .23 .17 .13 .32 .23 .17 .13 .22 .16 .13 .21 .16 .13 .20 .16 .12 .11
3-Lamp XP • Class I, Division 1, Groups C and D; Class I, Division 2, Groups C and D; Class II,
Division 1 and 2, Groups E, F and G; Class III
• UL 844 for Hazardous Locations and use inside paint spray booths and rooms. Also meets
requirements for NFPA Standard 33 and NEC Article 516
• Simultaneous Presence
• UL 1598A Marine Outside Type
• CSA Approved
• Zone 1, Groups IIA and IIB
• Zone 2, Groups IIA, IIB and IIC
• Seismic tested by Structural Dynamics Research Corporation (full scale fragility qualification)
tested in frequencies of 1 to 31.6 Hertz in 3-plane axis with maximum G force of 18.67 achieved
• NEMA 3, 4X, 7CD, 9EFG
(Lamps included)
Hub Size
Description (inches) Voltage Catalog Number
32 Watt, Instant Start, 3/4 120-277V 50/60 HZ
XP265-4-3L-U
Medium Bi-Pin, T8 265mA, 48"
34 Watt, Rapid Start F40T12, 3/4 120-277V 50/60 HZ XP430-4-3L-U
Medium Bi-Pin, 430mA, 48" (export only)
Three-Lamp 60 Watt, Rapid Start, High
Four Foot Output, F48T12/HO Recessed 3/4 120-277V 50/60 HZ XP800-4-3L-U
Fixture Double Contact, 800mA, 48"
110 Watt, Rapid Start, Very High 120V/60 HZ XP1500-4-3L-A
Output, F48T12/VHO Recessed 3/4
Double Contact, 1500mA, 48" 277V/60 HZ XP1500-4-3L-C
Add 5/8 inch to fixture height and 1/4 inch to width when wire guard is used.
FLUORESCENT
XP XPSeries
Series
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
Coefficients of Utilization
% Effective Ceiling Cavity
Reflectance 80 70 50 30 10 0
lcc
% Wall Reflectance
lw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR 20% Effective Floor Cavity Reflectance
0 .79 .79 .79 .79 .77 .77 .77 .77 .73 .73 .73 .70 .70 .70 .67 .67 .67 .66
1 .71 .67 .64 .61 .69 .66 .63 .60 .63 .60 .58 .60 .58 .56 .58 .56 .55 .53
2 .64 .57 .52 .48 .62 .56 .51 .47 .54 .50 .46 .51 .48 .45 .49 .47 .44 .43
3 .57 .50 .44 .39 .56 .48 .43 .38 .46 .42 .38 .44 .40 .37 .43 .39 .36 .35
4 .52 .43 .37 .32 .50 .42 .36 .32 .41 .35 .31 .39 .34 .31 .37 .34 .30 .29
5 .47 .38 .32 .27 .46 .37 .31 .27 .36 .30 .26 .34 .30 .26 .33 .29 .26 .24
6 .43 .34 .27 .23 .42 .33 .27 .23 .32 .26 .22 .31 .26 .22 .30 .25 .22 .21
7 .40 .30 .24 .20 .39 .30 .24 .20 .29 .23 .19 .28 .23 .19 .27 .22 .19 .18
8 .37 .27 .21 .17 .36 .27 .21 .17 .26 .21 .17 .25 .20 .17 .24 .20 .17 .15
9 .34 .25 .19 .15 .33 .24 .19 .15 .24 .19 .15 .23 .18 .15 .22 .18 .15 .13
10 .32 .23 .17 .13 .31 .22 .17 .13 .22 .17 .13 .21 .16 .13 .20 .16 .13 .12
FLUORESCENT
XP Series
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
4-Lamp XP • Class I, Division 1, Groups C and D; Class I, Division 2, Groups C and D; Class II,
Division 1 and 2, Groups E, F and G; Class III
• UL 844 for Hazardous Locations and use inside paint spray booths and rooms. Also meets
requirements for NFPA Standard 33 and NEC Article 516
• Simultaneous Presence
• UL 1598A Marine Outside Type
• CSA Approved
• Zone 1, Groups IIA and IIB
• Zone 2, Groups IIA, IIB and IIC
• Seismic tested by Structural Dynamics Research Corporation (full scale fragility qualification)
tested in frequencies of 1 to 31.6 Hertz in 3-plane axis with maximum G force of 18.67 achieved
(Lamps included) • NEMA 3, 4X, 7CD, 9EFG
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
Coefficients of Utilization
% Effective Ceiling Cavity
Reflectance 80 70 50 30 10 0
lcc
% Wall Reflectance
lw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR 20% Effective Floor Cavity Reflectance
0 .86 .86 .86 .86 .84 .84 .84 84 .80 .80 .80 .77 .77 .77 .73 .73 .73 .72
1 .76 .71 .67 .63 .74 .69 .65 .62 .66 .63 .60 .63 .60 .58 .60 .58 .56 .54
2 .67 .60 .54 .48 .65 .58 .53 .48 .56 .51 .46 .53 .49 .45 .51 .47 .44 .42
3 .61 .51 .44 .39 .59 .50 .43 .38 .48 .42 .37 .45 .41 .36 .43 .39 .36 .34
4 .55 .45 .37 .32 .53 .44 .37 .31 .42 .35 .31 .40 .34 .30 .38 .33 .30 .28
5 .50 .39 .32 .26 .48 .38 .31 .26 .37 .30 .26 .35 .30 .25 .34 .29 .25 .23
6 .46 .35 .28 .22 .44 .34 .27 .22 .33 .27 .22 .31 .26 .22 .30 .25 .21 .20
7 .42 .31 .24 .19 .41 .31 .24 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .17
8 .39 .28 .21 .17 .38 .28 .21 .27 .27 .21 .17 .26 .20 .16 .25 .20 .16 .15
9 .36 .26 .19 .15 .35 .25 .19 .15 .24 .19 .15 .23 .18 .14 .23 .18 .14 .13
10 .34 .24 .17 .13 .33 .23 .17 .13 .22 .17 .13 .22 .16 .13 .21 .16 .13 .11
FLUORESCENT
XP Series
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
2-Lamp Biaxial XP
• Class I, Division 1, Groups C and D; Class I, Division 2, Groups C and D; Class II,
Division 1 and 2, Groups E, F and G; Class III
• UL 844 for Hazardous Locations and use inside paint spray booths and rooms. Also meets requirements
for NFPA Standard 33 and NEC Article 516
• Simultaneous Presence
• UL 1598A Marine Outside Type
• CSA Approved
• Zone 1, Groups IIA and IIB
• Zone 2, Groups IIA, IIB and IIC
• Seismic tested by Structural Dynamics Research Corporation (full scale fragility qualification) tested in
(Lamps included)
frequencies of 1 to 31.6 Hertz in 3-plane axis with maximum G force of 18.67 achieved
• NEMA 3, 4X, 7CD, 9EFG
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
3-Lamp Biaxial XP
• Class I, Division 1, Groups C and D; Class I, Division 2, Groups C and D; Class II, Division 1 and 2,
Groups E, F and G; Class III
• UL 844 for Hazardous Locations and use inside paint spray booths and rooms. Also meets requirements for
NFPA Standard 33 and NEC Article 516
• Simultaneous Presence
• UL 1598A Marine Outside Type
• CSA Approved
• Zone 1, Groups IIA and IIB
• Zone 2, Groups IIA, IIB and IIC
• Seismic tested by Structural Dynamics Research Corporation (full scale fragility qualification) tested
(Lamps included)
in frequencies of 1 to 31.6 Hertz in 3-plane axis with maximum G force of 18.67 achieved
• NEMA 3, 4X, 7CD, 9EFG
Add 5/8 inch to fixture height and 1/4 inch to width when wire guard is used.
FLUORESCENT
XP Series
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
4-Lamp Biaxial XP
• Class I, Division 1, Groups C and D; Class I, Division 2, Groups C and D; Class II, Division 1 and 2,
Groups E, F and G; Class III
• UL 844 for Hazardous Locations and use inside paint spray booths and rooms. Also meets
requirements for NFPA Standard 33 and NEC Article 516
• Simultaneous Presence
• UL 1598A Marine Outside Type (Lamps included)
• CSA Approved
• Zone 1, Groups IIA and IIB
• Zone 2, Groups IIA, IIB and IIC
• Seismic tested by Structural Dynamics Research Corporation (full scale fragility qualification) tested in
frequencies of 1 to 31.6 Hertz in 3-plane axis with maximum G force of 18.67 achieved
• NEMA 3, 4X, 7CD, 9EFG
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
XP Series Emergency
• Class I, Division 1, Groups C and D; Class I, Division 2, Groups C and D; Class II,
Divisions 1 & 2, Groups E, F, and G; Class III
• UL listed and labeled 1598, 844 and 924
• Emergency illumination exceeds NEC, NFPA Life Safety Code and UL 90 minute
requirement
• Factory-sealed
• NEMA 3, 4X, 7CD, 9EFG: IP66
• Zone 1, Groups IIA and IIB
• Zone 2, Groups IIA, IIB and IIC
(Lamps included)
Hub Size
Description (inches) Voltage Catalog Number
120V/60 HZ XP430-4-2L-U-EM
34 Watt, Rapid Start F40T12 1/2
Two Lamp 277V/60 HZ XP430-4-2L-U-EM
Medium Bi-Pin 430mA, 48" (export only)
Four Foot 220V/50 HZ XP430-4-2L-U-EM
Emergency
60 Watt, Rapid Start, High Output
Fixture 1/2 120V-277V 50/60 HZ XP800-4-2L-U-EM
F48T12 Recessed
Double Contact, 800mA, 48"
32 Watt, Instant Start 1/2 120V-277V 50/60 HZ XP265-4-2L-U-EM
Medium Bi-Pin T8 265mA, 48"
120V/60 HZ XP430-4-3L-U-EM
34 Watt, Rapid Start F40T12 1/2
Three Lamp 277V/60 HZ XP430-4-3L-U-EM
Medium Bi-Pin 430mA, 48" (export only)
Four Foot 220V/50 HZ XP430-4-3L-U-EM
Emergency
60 Watt, Rapid Start, High Output
Fixture 1/2 120V-277V 50/60 HZ XP800-4-3L-U-EM
F48T12 Recessed
Double Contact, 800mA, 48"
32 Watt, Instant Start 1/2 120V-277V 50/60 HZ XP265-4-3L-U-EM
Medium Bi-Pin T8 265mA, 48"
Description/Features
• Self-contained unitized construction
• Explosion-proof housing, corrosion-resistant, copper-free aluminum
• Contains sealed, maintenance-free high temperature rechargeable nickel cadmium battery
charger and AC ballast
• Explosion-proof test switch and charging indicator pilot light
• Same fixture body as standard XP Series fixture allows the fixture to be used for both normal
and emergency operation. Emergency mode does not affect normal fixture operation
Operation
Fixture operates normally on 120V, 277V 60HZ or 220V 50HZ as specified. When AC power fails,
fixture automatically switches to the emergency mode, keeping one lamp illuminated, providing up
to 1200 lumens for at least 90 minutes of safe egress lighting, regardless of type of lamps.
When AC power is restored, the unit switches to charging mode and normal lighting resumes.
The charging indicator light provides a visual indication that the battery is charging.
FLUORESCENT
XP XPSeries
Series
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
Accessories
POLYCARBONATE SHIELDS
DESCRIPTION CATALOG NUMBER
STAINLESS STEEL GUARDS 3-Lamp 2-Ft. Fixtures 86000
DESCRIPTION CATALOG NUMBER 2-Lamp 2-Ft. Fixtures 86001
2-Lamp 2-Ft. Fixtures 86321 2-Lamp 4-Ft. Fixtures 86002
2-Lamp 4-Ft. Fixtures 86320 3-Lamp 4-Ft. Fixtures 86003*
3-Lamp 4-Ft. Fixtures 86345 Four Lamp Fixtures Require Two Cat. #86002 Shields.
Four Lamp Fixtures Require Two Cat. #86320 Guards *One 86345 guard required.
Typical Installations
BEAM
DROP
SHOCK
WALL OR CEILING
FLUORESCENT
XP XPSeries
Series
Explosion Proof • Paint Spray Booth • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Factory Sealed
SWIVEL
RIGID
FLEXIBLE
FPF 2 SERIES F
P
Non-Metallic Fixture for Food Processing
F
•
•
NSF Certified Food Equipment
High Pressure Hose Down
2
• UL 1598A Wet Locations
• Non-Metallic LED Fixture
• CUL
713.943.0340 | azz.com/rigalite
FPF 2 SERIES
Non-Metallic Fixture for Food Processing
Industry leading
watershed design. Stainless steel
external hardware.
2 LAMP WATTAGE
380 = 380mA, 86 Watt
6 OPTIONS2
AL95 = 95% Premium Specular Reflector
265 = 265mA, 59 or 32 Watt (T8 Lamps) F = Single Fuse
T5HO = T5HO 54 Watt HL = Hi-Lumen Ballast (T8 Only)
L = Lamps
3 NOMINAL FIXTURE LENGTH LC = Coated Lamps
2 = 2 Foot (T5HO consult factory) R = Radio Interference Filter
4 = 4 Foot SS = Stainless Steel End Caps
8 = 8 Foot EON = Emergency Only
ENN = Emergency & Normal
4 NUMBER OF LAMPS
1 = 1 Lamp
ENS = Emergency & Normal Switched
1 UP = 2 Lamps Down and 1 Lamp Up
2 = 2 Lamp
3 = 3 Lamp (4 ft. T5HO Only)
1
Fixtures are furnished with FPFXDMKT,
non-metallic cord grip and 3 ft. long #16
4 = 4 Lamp (8 ft. Only) AWG 3 conductor type SOA cable.
6 = 6 Lamp (8 ft. T5HO Only) 2
Consult factory for pricing.
Not Available as Emergency
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
FLUORESCENT
FPF 2 Series
Non-Metallic Housing • UL 1598 Wet Locations • CUL • High Pressure Hose Down • Indoor or Outdoor • NSF Certified
Fluorescent Series
For fixtures with stainless steel endcaps, emergency labels are installed
on each side in the center, clearly visible through the acrylic housing.
334
Fluorscent Series Options FLUORESCENT
FPF 2 Series
Non-Metallic Housing • UL 1598 Wet Locations • CUL • High Pressure Hose Down • Indoor or Outdoor • NSF Certified
Fluorescent Series
(Lamps not included)
Accessories
Fixed Mounting Bracket Kit Chain Mounting Kit Stainless Steel Band Clamp
Stainless Steel - For 3/8 in. Bolts (not provided) Stainless Steel Catalog Number: FPFBNDMKT
Catalog Number: FPFXDMKT Catalog Number: FPFCMKT1 Shipping Weight: 1.0 lbs.
Shipping Weight: 0.4 lbs. Shipping Weight: 0.2 lbs.
Mini Receptacle 3P Male Pigtail Assembly- 3 ft. Cable Mini Plug 3P- 6 ft. Mini Cable
Catalog Number: 64005 Other Lengths Available - Consult Factory Other Lengths Available - Consult Factory
Shipping Weight: 0.1 lbs. Catalog Number: 53108 Catalog Number: 60006
Shipping Weight: 0.4 lbs. Shipping Weight: 0.6 lbs.
713.943.0340 | azz.com/rigalite
HEF SERIES
Industrial Fluorescent Lighting for Hazardous Locations
Each HEF Series fixture is individually tested for functional and dielectrical strength at the factory to assure quality
and reliability and arrives assembled including reflectors, reducing installation time and cost.
Thermally protected
Class P ballast.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
FLUORESCENT
HEF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 844 • CSA Certified • Wet Locations
Certification Guide
OPERATING TEMPERATURE CODE
CLASS I, DIVISON 2 CLASS II, DIVISION 1 RATED AMBIENT SUPPLY
HEF SERIES GROUPS A, B, C & D GROUPS F & G TEMPERATURE WIRE
HEF 800 T3C (160°C/320°F) T6 (85°C/185°F) 25°C (77°F) 90°
2 & 3 LAMPS
HEF 430
T6 (85°C/185°F) T6 (85°C/185°F) 40°C (104°F) 90°
2 & 3 LAMPS
HEF 265 T4A (120°C/248°F) T6 (85°C/185°F) 40°C (104°F) 90°
2 & 3 LAMPS
HEF T5HO
2, 3, 4 & 6 LAMPS T3C (160°C/320°F) T6 (85°C/185°F) 40°C (104°F) 90°
Options
FLUORESCENT
HEF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 844 • CSA Certified • Wet Locations
54 Watt, T5HO
Miniature Bi-Pin 120-277V 50/60HZ Tempered Glass HEFT5H0-2L-TM-U
2 Lamp 48"
60 Watt, Rapid Start2
High Output 120-277V 50/60HZ Tempered Glass HEF800-2L-TM-U
Recessed Double Contact
800mA Lamps, 48"
32 Watt, Instant Start
Medium Bi-Pin 120-277V 50/60HZ Tempered Glass HEF265-3L-TM-U
T8, 265mA, 48"
34 Watt, Rapid Start 3 120V-277V 50/60HZ Tempered Glass HEF430-3L-TM-U
Medium Bi-Pin
Three Lamp 430mA Lamps, 48" (export only)
Fixture 54 Watt,T5HO
Miniature Bi-Pin 120-277V 50/60HZ Tempered Glass HEFT5HO-3L-TM-U
2 Lamp, 48"
60 Watt, Rapid Start, High2
Output Recessed Double 120-277V 50/60HZ Tempered Glass HEF800-3L-TM-U
Contact, 800mA, 48"
1Partnumbers are for pendant mount fixtures. For end mount/thru wire application, see options.
2Minstarting temp for 60 watt fixtures is -20°F.
3Two ballasts available for 3-40 watt lamps for outboard option.
FLUORESCENT
HEF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 844 • CSA Certified • Wet Locations
HEF265-3
% Effective Ceiling
80 50 10
Cavity Reflectance rcc Deg. Parl. 22.5 45 67.5 Norm
% Wall Reflectance rw 50 30 10 50 30 10 50 30 10
0 2011 2011 2011 2011 2011
Room Cavity Ratio
RCR
Effective Floor Cavity Reflectance 20% 5 2019 2013 2013 2012 2010
0 .84 .84 .84 .78 .78 .78 .72 .72 .72 15 1964 1968 1991 2008 2012
1 .71 .68 .65 .67 .64 .62 .61 .60 .56 25 1839 1864 1920 1955 1965
2 .61 .56 .51 .57 .53 .49 .53 .50 .47
35 1653 1706 1768 1831 1841
3 .53 .46 .41 .49 .44 .40 .46 .42 .39
4 .46 .39 .34 .43 .38 .33 .40 .36 .33 45 1408 1491 1578 1632 1637
5 .40 .34 .28 .38 .32 .28 .35 .31 .27 55 1099 1201 1286 1275 1256
6 .36 .29 .24 .34 .28 .24 .32 .27 .23 65 714 812 822 766 741
7 .32 .26 .21 .30 .25 .21 .28 .24 .20
8 .29 .23 .18 .28 .22 .18 .26 .21 .18
75 309 363 325 266 248
9 .26 .20 .16 .25 .20 .16 .24 .19 .16 85 26 32 27 26 26
10 .24 .18 .14 .23 .18 .14 .22 .17 .14 90 0 0 0 0 0
HEF800-2
% Effective Ceiling
80 50 10
Cavity Reflectance rcc Deg. Parl. 22.5 45 67.5 Norm
% Wall Reflectance rw 50 30 10 50 30 10 50 30 10 0 1882 1882 1882 1882 1882
Room Cavity Ratio
RCR
Effective Floor Cavity Reflectance 20% 5 1889 1885 1883 1883 1883
0 .83 .83 .83 .77 .77 .77 .71 .71 .71 15 1837 1842 1861 1878 1882
1 .73 .71 .68 .69 .67 .65 .64 .62 .61 25 1717 1743 1795 1834 1844
2 .64 .60 .56 .61 .57 .54 .56 .54 .52 35 1543 1595 1674 1731 1747
3 .57 .52 .47 .54 .50 .46 .50 .47 .45
4 .50 .45 .40 .48 .43 .39 .45 .41 .38 45 1315 1399 1494 1587 1600
5 .44 .38 .34 .42 .37 .33 .40 .36 .32 55 1025 1131 1259 1267 1249
6 .40 .33 .29 .38 .32 .29 .35 .31 .28 65 663 787 829 812 797
7 .35 .29 .25 .34 .29 .25 .32 .28 .24 75 285 368 369 314 283
8 .32 .26 .21 .30 .25 .21 .28 .24 .21
9 .28 .22 .18 .27 .22 .18 .25 .21 .18 85 23 33 30 30 30
10 .26 .20 .16 .24 .19 .16 .23 .19 .16 90 0 0 0 0 0
HEF800-3
% Effective Ceiling
80 50 10
Cavity Reflectance rcc Deg. Parl. 22.5 45 67.5 Norm
% Wall Reflectance rw 50 30 10 50 30 10 50 30 10
0 2693 2693 2693 2693 2693
Room Cavity Ratio
RCR
Effective Floor Cavity Reflectance 20% 5 2688 2681 2677 2674 2674
0 .76 .76 .76 .71 .71 .71 .65 .65 .65 15 2634 2630 2659 2685 2693
1 .67 .65 .63 .63 .61 .60 .59 .57 .56 25 2456 2493 2564 2612 2627
2 .60 .56 .52 .56 .53 .50 .52 .50 .48 35 2215 2282 2383 2447 2462
3 .53 .48 .44 .50 .46 .43 .47 .44 .42
4 .47 .42 .38 .44 .40 .37 .42 .38 .36 45 1887 1989 2098 2181 2181
5 .41 .36 .32 .39 .35 .31 .37 .33 .30 55 1468 1605 1701 1663 1628
6 .37 .31 .27 .35 .30 .27 .33 .29 .26 65 958 1101 1062 989 943
7 .33 .27 .24 .31 .27 .23 .30 .26 .23 75 399 477 403 333 313
8 .29 .24 .20 .28 .23 .20 .27 .23 .20
9 .26 .21 .17 .25 .20 .17 .24 .20 .17 85 31 35 31 31 31
10 .24 .19 .15 .23 .18 .15 .22 .18 .15 90 0 0 0 0 0
FLUORESCENT
HEF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 844 • CSA Certified • Wet Locations
Accessories
Adjustable
Angle Bar Wall/Ceiling Mounting Kit
Chain Mounting Kit 53044- Plated Steel
53044SS- Stainless
53045- Plated Steel Shipping Weight: 1.41 lbs.
53045SS- Stainless
Shipping Weight: 1.5 lbs.
Chain Not Included
Fixed 45°
Wall/Ceiling Mounting Kit
53043 Plated Steel
53043SS- Stainless
Shipping Weight: 1.61 lbs.
NOTE:
When wall/ceiling bracket is adjusted to the 45° position, all dimensions
are same as shown for fixed 45° bracket.
102
RFL/MFL SERIES R
F
Hazardous Location High Pressure Hose Down Recessed Fluorescent
L
• Class I, Division 2, Groups A, B, C & D
• UL 844 Hazardous Locations
• UL 924 Emergency Lighting
• UL 1598A Marine Inside Drip Proof
• CUL
• High Pressure Hose Down
• Grid or Ceiling Mount
Baked-on powder
polyester finish. Bolt on gasketed cast
aluminum 1/2 NPT hub on
both ends.
Welded
aluminum construction.
4
RFL 265-24-4L-G-U-XX
1 2 3 4 5 6 7
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
Options
FLUORESCENT
RFL/MFL Series
Hazardous Locations • Class I, Division 2 • UL 1598A Inside Drip Proof • High Pressure Hose Down • UL 844 • UL 924 • CUL
Certification Guide
65°
90°
1000 55°
Ambient Class I, Division 2 Supply Wire Suitable 75° 45°
Model Temperature °C Groups A, B, C & D Temp °C 65°
RFL265 40 T4A 90 1000 2000
55° 35°
RFL425 40 T4A 90
RFL430 40 T4A 90 45°
Accessories
713.943.0340 | azz.com/rigalite
WFH SERIES
Industrial Fluorescent High-Bay Lighting for Hazardous Locations
Highly efficient
specular reflector.
Four or six T8 or
T5HO lamps.
FLUORESCENT
WFH Series
Class l, Division 2 • Class II, Division 2 • Class III • Wash Down Rated • UL/CUL • NSF Certified • NEMA 4X
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
FLUORESCENT
WFH Series
Class l, Division 2 • Class II, Division 2 • Class III • Wash Down Rated • UL/CUL • NSF Certified • NEMA 4X
Certification Guide
Note:
All data provided for six 54W lamps. Lamps rated for 4450 lumens per lamp.
FLUORESCENT
WFH Series
Class l, Division 2 • Class II, Division 2 • Class III • Wash Down Rated • UL/CUL • NSF Certified • NEMA 4X
Accessories
713.943.0340 | azz.com/rigalite
HNMF2
Non-Metallic Enclosed and Gasketed Fluorescent Luminaire for Hazardous Locations
• Fixtures are dust, moisture and corrosion resistant and can be used in many
hazardous applications
• Housing is UL 5VA non-flammable listed and UL 746C listed for outdoor use
FLUORESCENT
HNMF2
Non-Metallic
Non-Metallic
Enclosed
Enclosed
and Gasketed
and Gasketed
Fluorescent
Fluorescent
Luminaire
Luminaire
for Hazardous
for Hazardous
Locations
Locations
HNMF2 265-4-2-U-XX
1 2 3 4 5 6
6 OPTIONS1
P = Prismatic Polycarbonate Lens 2
EM = Emergency Battery Backup
2 LAMP CURRENT/ LAMP WATTAGE (265mA Only - T5H0 4 Lamp Only)
430 = 430mA, 34 Watt (export only) FB = Fuse Block
425 = 425mA, 40/75 Watt (Slimline) L = Lamps
265 = 265mA, 32 Watt (T8 Lamp) TW = Thru Wire Fittings
T5H0 = 54 Watt Cable Installations Only
HL = Hi-Lumen Ballast (T8 Only)
3 NOMINAL FIXTURE LENGTH TP = Tamper Proof Screw Kit Poly
4 = 4 Foot TPSS = Tamper Proof Screw Kit Stainless
8 = 8 Foot SP = Specular Reflector (85%)3
SSL = Stainless Steel Latches
4 NUMBER OF LAMPS
1Consult factory for pricing.
1 = 1 Lamp 2
Polycarbonate lens not available for 8 foot fixtures.
2 = 2 Lamp 32L Only.
3 = 3 Lamp
4 = 4 Lamp (8 ft. T8 and T5HO Only)
6 = 6 Lamp (8 ft. T8 and T5HO Only)
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
FLUORESCENT
HNMF2
Non-Metallic Enclosed and Gasketed Fluorescent Luminaire for Hazardous Locations
Dimensions (inches)
Boxed Shipping Volume
HNMF2 SERIES A Weight
B C (Boxed Fixtures)
NOTE:
All data provided for two 32W, rapid start, cool white F40CW/RS/WM lamps.
Lamps rated for 2850 lumens per lamp. Use 1.509 multiplier for 60W F48T12/HO high output lamps.
NMF 2 SERIES N
M
F
Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations
• NEMA 4X 2
• UL 1598 Wet & Damp Locations
• CUL
• IP65
• NSF Enclosure
713.943.0340 | azz.com/rigalite
NMF2 SERIES
Non-Metallic Enclosed and Gasketed Fluorescent Lighting
NMF2 265-4-2-U-D-XX
1 2 3 4 5 6 7
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
FLUORESCENT
NMF 2 Series
Non-Metallic • UL 1598 Wet and Damp Locations • Dust Tight • IP65 • CUL • NSF Enclosure
NOTE:
All data provided for two 32W, rapid start, cool white F40CW/RS/WM lamps.
Lamps rated for 2850 lumens per lamp. Use 1.509 multiplier for 60W F48T12/HO high output lamps.
FLUORESCENT
NMF 2 Series
Non-Metallic • UL 1598 Wet and Damp Locations • Dust Tight • IP65 • CUL • NSF Enclosure
Accessories
NEED PHOTO
713.943.0340 | azz.com/rigalite
NMFH SERIES
Non-Metallic Hose Down Rated Fluorescent High Bay
Fixture tested for hose-down conditions up to 1200 psi
Sloped
surfaces.
Fiberglass
reinforced housing.
Stainless steel
latches.
Impact resistant
clear acrylic or
polycarbonate lens.
FLUORESCENT
NMFH Series
UL 1598 Wet Locations • Non-Metallic • IP66 • NEMA 4X • NSF Enclosure • Hose Down
1
Consult factory for pricing.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
FLUORESCENT
NMFH Series
UL 1598 Wet Locations • Non-Metallic • IP66 • NEMA 4X • NSF Enclosure • Hose Down
D C
B
A
D C F
B
E
4 foot, 4 Lamp 6.00 .75 14.75 52.00 46.50 1.50 27 lbs. 3.11 cu. ft.
4 foot, 6 Lamp 6.00 .75 14.75 52.00 46.50 1.50 27 lbs. 3.11 cu. ft.
FLUORESCENT
NMFH Series
UL 1598 Wet Locations • Non-Metallic • IP66 • NEMA 4X • NSF Enclosure • Hose Down
NOTE: All data provided for six 54W lamps. Lamps rated for 4450 lumens per lamp.
FLUORESCENT
NMFH Series
UL 1598 Wet Locations • Non-Metallic • IP66 • NEMA 4X • NSF Enclosure • Hose Down
Accessories
713.943.0340 | azz.com/rigalite
WFHN SERIES
High-Bay Lighting for Heavy Hose-Down Environments
Stainless steel
captive hardware.
Highly efficient
specular reflector.
Hinged reflector assembly
for easy access to drivers
and wiring. Stainless Steel
hinge optional.
1 BASIC SERIES
WFHN Fluorescent Fixture 5 LENS TYPE
CA = Clear Acrylic
UL 1598 Wet Locations
UL 8750 LED Safety PA = Prismatic Acrylic
CUL Listed CP = Clear Polycarbonate
NSF Certified Food Equipment
Wash Down Rated
6 VOLTAGE/FREQUENCY
2 LAMP CURRENT/LAMP WATTAGE
265 = 265mA, 59, 32 Watt (T8 Lamps)
H = 347V 60 HZ
N = 347 thru 480V 50/60 HZ
T5HO = 54 Watt Four Foot Lamp U = 120 thru 277V 50/60 HZ
48 = 480V 60HZ
3 NOMINAL FIXTURE LENGTH
24 = 2 x 4 Foot 7 MOUNTING
DH = Dual Hub 1/2 in. NPT
4 NUMBER OF LED STRIPS SH = Single Hub 3/4 in. NPT
4 = 4 Lamps
6 = 6 Lamps 8 OPTIONS1
HL = High Lumen Ballast (T8 Only)
DM = Dimming Ballast
EM = Emergency Battery Backup
EM/NON = Non-Hazardous Emergency Backup
F = Single Fuse- For USL luminairies only (For
luminairies rated 277 VAC or less)
DF = Double Fuse- For USL luminairies only (For
luminairies rated 277 VAC or less)
L = Lamps
LC = Coated Lamps
SP = 95% Specular Reflector
WO = White Optic Reflector
HNG = Hinged Lens Frame
Z = Cold Storage (-30°C/-22°F Minimum
Starting Temp.)
OB = Out Board Option
1 Consult factory for pricing.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
FLUORESCENT
WFHN Series
UL 1598 Wet Location • CUL • High Pressure Hose Down • NSF Certified
Accessories
713.943.0340 | azz.com/rigalite
SAF SERIES
Hazardous Location Mogul Base HID and Compact Fluorescent
3
• Reflectors cannot be added. Lamp to be 100W
LAMP TYPE1 DC bayonet base.
• Available with maximum 150W HPS & 250W MH
S = High Pressure Sodium lamp.
(70, 100, 150, 200, 250, 400 Watt) 4 Not available with multi-tap ballast unless
Certification Guide
SIMULTANEOUS
CLASS I, DIV 2 GROUPS A,B,C,D CLASS II & III PRESENCE
SUPPLY
WIRE
GLOBE GLOBE GLOBE GLOBE UL 1598A SUITABLE
MODEL AMBIENT ° C GUARD W/REFL REFRACTOR GROUPS GUARD REFRACTOR GUARD REFRACTOR OUTDOOR CSA TEMP °C
SAF05S 40 T3 T3 T3B E,F,G T4A T6 T2 T2B YES YES 90
SAF05S 55 T3 T3 - - - - - - YES YES 90
SAF05S 65 T2D T2D T2D - - - - - YES YES 110
SAF07S 40 T3 T3 T3B E,F,G T4A T6 T3 T3C YES YES 90
SAF07S 55 T3 T3 - - - - - - YES YES 90
SAF07S 65 T2D T2D T2D - - - - - YES YES 110
SAF10S 40 T2D T2D T3 E,F,G T3C T6 T2B T3 YES YES 90
SAF10S 55 T2D T2D - - - - - - YES YES 90
SAF10S 65 T2C T2C - - - - - - YES YES 110
SAF15S 40 T2B T2B T2C E,F ** T3 - T2 T2B YES YES 90
SAF15S 40 T2B T2B T2C E,F,G - T4A - - YES YES 90
SAF15S 55 T2B T2B - - - - - - YES YES 90
SAF15S 65 T2A T2A - - - - - - YES YES 110
SAF25S 40 T1 (350) T1 (350) T1(350) E,F,G T3C T3C T1 (350) T1 (350) YES YES 105
SAF25S 55 T1 (350) T1 (350) - - - - - - YES YES 110
SAF25S 65 T1 T1 - - - - - - YES YES 125
SAF40S 40 T1 T1 T1 E,F,G - T3B - - YES YES 110
SAF10H 40 T2B T2B T2C E,F,G - T4 - - YES YES 125
SAF15H 40 T2 T2 T2 E,F,G - T4 - T2 YES YES 125
SAF15H 55 T2 T2 - - - - - - YES YES 125
SAF17H 40 T2 T2 T2 E,F,G - T4 - T2 YES YES 125
SAF17H 55 T2 T2 - - - - - - YES YES 125
SAF25H 40 T1 T1 T2 E,F,G - T4 - T2 YES YES 110
SAF40H 40 T1 T1 T1 E,F,G - T3B - - YES YES 110
SAFR05S 40 - - T3 E,F,G - T4A - T3 YES YES 90
SAFR05S 55 - - T3 - - - - - YES YES 90
SAFR07S 40 - - T3 E,F,G - T4A - T3 YES YES 90
SAFR07S 55 - - T3 - - - - - YES YES 90
SAFR10S 40 - - T2D E,F,G - T3C - T2B YES YES 90
SAFR10S 55 - - T2D - - - - - YES YES 90
SAFR15S 40 - - T2B E,F - T3 - T2 YES YES 90
SAFR15S 55 - - T2B - - - - - YES YES 90
SAFR10H 40 - - T2B - - - - - YES YES 105
SAFR10H 55 - - T2 - - - - - YES YES 125
SAFR17H 40 - - T2 - - - - - YES YES 105
SAFR17H 55 - - T2 - - - - - YES YES 125
SAF26F 40 T3 T3 T3B E,F,G T4A T6 T3 T3C YES - 75
SAF32F 40 T2B T2B T2B E,F,G T4A T4 - - YES - 75
SAF42F 40 T2A T2A T2A E,F,G T4A T4 - - YES - 75
SAF52F 40 T2B T2B T2B E,F,G T4A T4 - - YES - 75
SAF64F 40 T2B T2B T2B E,F,G T4A T4 - - YES - 75
SAF84F 40 T2A T2A T2A E,F,G T4A T4 - - YES - 75
*GROUPS E & F ONLY FOR STANCHION MOUNT. GROUPS E, F, & G FOR ALL OTHER MOUNTS.
NOTE: ALL SAF SERIES FIXTURES WITH GLOBE AND GUARD RATED 175W MAXIMUM AT 40° C ARE ADDITIONALLY LISTED FOR
CLASS I ZONE 2 AEx OR EX nR II AND ARE MARKED WITH THE OPERATING TEMPERATURE 160° C OR CODE T3
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
High Pressure Sodium with Globe and Guard 70-400 Watts (continued)
(Lamps not included)
High Pressure Sodium with Threaded Refractor and Guard 70-400 Watts
(Lamps not included)
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
High Pressure Sodium with Threaded Refractor and Guard 70-400 Watts (continued)
(Lamps not included)
25° STANCHION MOUNT 70 1-1/4 SAFR07-S-04-T5G-S 31.6 SAFR07S04 SMS SRT25GL SXP25WG
70 1-1/2 SAFR07-S-04-T5G-S1 31.6 SAFR07S04 SMS1 SRT25GL SXP25WG
90° STANCHION MOUNT 70 1-1/4 SAFR07-S-04-T5G-L 31.6 SAFR07S04 SML SRT25GL SXP25WG
70 1-1/2 SAFR07-S-04-T5G-L1 31.6 SAFR07S04 SML1 SRT25GL SXP25WG
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Catalog Nos. shown are for fixtures with IES Type V closed bottom glass refractors, for other type refractors, refer to Catalog Number Logic page.
④ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture. Fixtures with Refractors are not suitable to ordered with reflectors.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
High Pressure Sodium with Refractor and Guard 70-400 Watts (continued)
(Lamps not included)
Conduit Catalog③ Shipping CONSISTS OF
Lamp➀
Mounting Style Size Number Weight Ballast Outlet
Watts Refractor③ Guard
(in.) 120/208/240/277V➁ (lbs.) Housing➁ Box
WALL MOUNT 70 1-14 SAF07-S-04-R5-G-W 35.9 SAF07S04 SMW SRE25GL SGU25W
70 1-1/2 SAF07-S-04-R5-G-W1 35.9 SAF07S04 SMW1 SRE25GL SGU25W
150④
150 1-1/4 SAF15-S-04-R5-G-L 35.3 SAF15S04 SML SRE25GL SGU25W
150④
150 1-1/2 SAF15-S-04-R5-G-L1 35.3 SAF15S04 SML1 SRE25GL SGU25W
250 1-1/4 SAF25-S-04-R5-G-L 47.1 SAF25S04 SML SRE45GL SGU25W
250 1-1/2 SAF25-S-04-R5-G-L1 47.1 SAF25S04 SML1 SRE45GL SGU25W
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
Metal Halide with Threaded Refractor and Guard 70-400 Watts (continued)
(Lamps not included)
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Catalog Nos. shown are for fixtures with IES Type V closed bottom glass refractors, for other type refractors, refer to Catalog Number Logic page.
Refer to Certification Guide to determine suitability of individual fixture. Fixtures with Refractors are not suitable to ordered with reflectors.
Fixtures with Refractors are not suitable to be ordered with reflectors.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Catalog Nos. shown are for fixtures with IES Type V closed bottom glass refractors, for other type refractors, refer to Catalog Number Logic page.
➀ 52 (2-26W Lamps); 64 (2-32W Lamps); 84 (2-42W Lamps) Fixtures with Refractors are not suitable to be ordered with reflectors.
➁ 120V thru 277V AC, 50/60HZ; 125V DC
➂ Catalog Nos. shown are for fixtures with IES Type V closed bottom glass refractors, for other type refractors, refer to Catalog Number Logic
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
➀ 52 (2-26W Lamps); 64 (2-32W Lamps); 84 (2-42W Lamps) Fixtures with Refractors are not suitable to be ordered with reflectors.
➁120V thru 277V AC, 50/60HZ; 125V DC
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
➀ 52 (2-26W Lamps); 64 (2-32W Lamps); 84 (2-42W Lamps) Fixtures with Refractors are not suitable to be ordered with reflectors.
➁ 120V thru 277V AC, 50/60HZ; 125V DC
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
Fluorescent Emergency
• Emergency illumination meets OSHA, Life Safety Code (NFPA 101),
and National Electric Code (NFPA 70) requirements
• Provides up to 700 lumens of initial light output in emergency mode
• Provides at least 90 minutes of illumination in emergency mode
• Sealed, maintenance free nickel cadmium batteries with a life
expectancy of 7-10 years
• Self contained unitized construction
• Starting temperature 0°C (32°F)
(Lamps included)
Conduit Shipping
Fixture Type Description Size Voltage➀ Catalog Number Weight
(In.) (Lbs.)
Stanchion/Pendant/Ceiling Mount 3/4 120v/60HZ SAF42-F-12-GG-C-EMO 22.2
Emergency (1) 42 Watt Fluorescent lamps 1 120v/60HZ SAF42-F-12-GG-C1-EMO 22.2
Only
Operation Wall Mount 3/4 120v/60HZ SAF42-F-12-GG-W-EMO 28.23
(1) 42 Watt Fluorescent lamps 1 120v/60HZ SAF42-F-12-GG-W1-EMO 28.23
Certification Guide
Class I, Division 2 Groups A,B, C, D Class II, Division 1, Class III Supply Wire
Ambient (When Used With) (When Used With) Suitable UL1598A
Model Lamp Watts
Temperature Globe w/ Temperature Outdoor
Globe Refractor Groups Globe Refractor
°C Reflector °C
SAF26F 40 26W T3 T3 T3B E,F,G T4A T6 90 YES
SAF32F 40 32W T2B T2B T2B E,F,G T4A T4 90 YES
SAF42F 40 42W T2D T2D T2D E,F,G T3C T4A 90 YES
SAF52F 40 52W (2 X 26W) T2B T2B T2B E,F,G T4A T4 90 YES
SAF64F 40 64W (2 X 32W) T2B T2B T2B E,F,G T4A T4 90 YES
SAF84F 40 84W (2 X 42W) T2A T2A T2A E,F,G T4A T4 90 YES
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
PENDANT MOUNT
with Threaded Glass Refractor and Guard
Accessories
Conduit Shipping
Catalog Hub Weight Shipping
OUTLET BOXES No. Size (In.) (Lbs.) Catalog Weight
RIGID PENDANT REFLECTORS➁ No. Description (Lbs.)
SMP 3/4 3.3
Standard Dome 2.0
Reflector
Fiberglass
SMP1 1 3.3 Reinforced
SR25D➀
Polyester
for use with
5-1/2 in. dia.
FLEXIBLE PENDANT
Globe
SMF 3/4 3.3
Standard Dome 3.0
Reflector
SMF1 1 3.3 Fiberglass
Reinforced
SR40D➀
Polyester
CEILING MOUNT for use with
7-3/4 in. dia.
SMC 3/4 4.1
Globe
① Not suitable for wall mount applications, fixtures with quartz option or with R2, R3 or
Refer to Certification Guide to determine suitability of individual fixture. R5 refractor
➁ Not suitable fixtures with quartz option or with R2, R3 or R5 refractor
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
Accessories
Shipping Shipping
Catalog Weight Catalog Weight
GUARDS No. Description (Lbs.) GLASS GLOBE No. Description (Lbs.)
.33 Heat and 4.0
Fiberglass Impact
Reinforced Resistant
Polycarbonate SGL25T Prismatic
SGU25P Guard for use Glass Globe
with 5-1/2 in. 250 Watt Max.
dia. Globe (5-1/2 in. dia.)
Shipping
Catalog
FUSE KIT Description Weight
No.
2.0 (Lbs.)
Stainless Steel
Guard for use
with 7-3/4 in.
SGU40SS Open fuse
dia. Globe
block kit- 600
SBF600 volt AC .06
maximum.
2.0
Wire Guard
for Glass Shipping
Refractors SAFETY CABLE Catalog No. Weight
SGU25W (R Type (Lbs.)
Refractors)
Accessories
Shipping Shipping
Catalog Weight GLASS Catalog Weight
PHOTO CELL KIT* No. Description (Lbs.) REFRACTORS No. Description (Lbs.)
Automatic on-off
SRE22GL IES Type II light
distribution
switch at (asymmetrical)
predetermined
light levels.
SPH25-120 120 volt only. .19
SRE23GL IES Type III light
distribution 11.0
REQUIRES
(asymmetrical)
FIELD
INSTALLATION.
713.943.0340 | azz.com/rigalite
SAFJ SERIES
Hazardous Locations Medium Base HID
Compact size.
Ballast housing and outlet
boxes are high strength,
corrosion resistant copper-
free cast aluminum alloy.
Corrosion resistant
stainless steel wire
guard.
• Exterior surfaces are covered with corrosion and chemical resistant baked-
on epoxy finish.
• External hardware is stainless steel, stainless steel inserts are available
as an option.
• Optional external dome or angle reflectors are corrosion, impact and heat
resistant molded polycarbonate.
HIGH PRESSURE SODIUM • METAL HALIDE
SAFJ Series
Hazardous Locations • Class l, Division 2, Class ll, Class lll • UL 1598A • UL 844 • Wet Locations • CUL
SAFJ 10-H-04-GG-P-XX
1 2 3 4 5 6 7
1 BASIC SERIES¹
SAFJ Medium Base HID
Class I, Division 2, Groups A, B, C, & D
Class II, Division 1 & 2, Groups E & F 5 GLOBE & GUARD
GG = Globe & Guard
Class III
Simultaneous Presence G = Globe only
Enclosed & Gasketed
Wet Locations
UL 1598A Marine Outside Type
6 MOUNTING STYLE
P = ¾" Pendant Mount
UL 844 Hazardous Locations P1 = 1" Pendant Mount
NEMA 3R,4X F = ¾" Flexible Pendant Mount
IP66 F1 = 1" Flexible Pendant Mount
CUL C = ¾" Ceiling Mount
ABS Type Approved C1 = 1" Ceiling Mount
W = ¾" Wall Mount
2 LAMP CURRENT/LAMP WATTAGE W1 = 1" Wall Mount
S = 1-¼" 25°Stanchion Mount
03 = 35 Watt
05 = 50 Watt S1 = 1-½" 25°Stanchion Mount
07 = 70 Watt L = 1-¼" 90°Stanchion Mount
10 = 100 Watt L1 = 1-½" 90°Stanchion Mount
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
HIGH PRESSURE SODIUM • METAL HALIDE
SAFJ Series
Hazardous Locations • Class l, Division 2, Class ll, Class lll • UL 1598A • UL 844 • Wet Locations • CUL
Certification Guide
Class I, Division 2
Class II, Division 1, Class III
Groups A,B, C, D
(When Used With)
Ambient Lamp (When Used With)
Temperature Globe w/ Globe w/
Model °C Type Watts Globe Reflector Groups Globe Reflector
SAFJ03S 40 HPS 35 T2D T2D E,F T3A T3A
SAFJ03S 55 HPS 35 T2C T2C E,F T3A T3A
SAFJ03S 65 HPS 35 T2B T2B E,F T3A T3A
SAFJ05S 40 HPS 50 T2D T2D E,F T3A T3A
SAFJ05S 55 HPS 50 T2C T2C E,F T3A T3A
SAFJ05S 65 HPS 50 T2B T2B E,F T3A T3A
SAFJ07S 40 HPS 70 T2A T2A E,F T3A T3A
SAFJ07S 55 HPS 70 T2 T2 E,F T3A T3A
SAFJ10S 40 HPS 100 T2A T2A E,F T3A T3A
SAFJ10S 55 HPS 100 T2 T2 E,F T3A T3A
SAFJ05H 40 MH 50 T2D T2D E,F T3A T3A
SAFJ05H 55 MH 50 T2C T2C E,F T3A T3A
SAFJ05H 65 MH 50 T2B T2B E,F T3A T3A
SAFJ07H 40 MH 70 T2B T2B E,F T3A T3A
SAFJ07H 55 MH 70 T2A T2A E,F T3A T3A
SAFJ10H 40 MH 100 T2 T2 E,F T3A T3A
OUTLET
BOXES
JMP JMF JMC JMW JMS JML
SAFJ
BALLAST
HOUSING
GLOBE
JGL15
GUARD
JGU15
JD15 JA15
REFLECTORS
236
HIGH PRESSURE SODIUM • METAL HALIDE
SAFJ Series
Hazardous Locations • Class l, Division 2, Class ll, Class lll • UL 1598A • UL 844 • Wet Locations • CUL
High Pressure Sodium with Globe and Guard 35-100 Watts (continued)
(Lamps not included)
Conduit Catalog Shipping CONSISTS OF
Lamp➀
Mounting Style Size Number Weight Ballast Outlet
Watts Globe Guard
(in.) 120/208/240/277V➁ (lbs.) Housing➁ Box
25° STANCHION 35 1-1/4 SAFJ03-S-04-GG-S 14 SAFJ03S04 JMS JGL15 JGU15
MOUNT
35 1-1/2 SAFJ03-S-04-GG-S1 14 SAFJ03S04 JMS1 JGL15 JGU15
50 1-1/4 SAFJ05-S-04-GG-S 15 SAFJ05S04 JMS JGL15 JGU15
50 1-1/2 SAFJ05-S-04-GG-S1 15 SAFJ05S04 JMS1 JGL15 JGU15
70 1-1/4 SAFJ07-S-04-GG-S 16 SAFJ07S04 JMS JGL15 JGU15
70 1-1/2 SAFJ07-S-04-GG-S1 16 SAFJ07S04 JMS1 JGL15 JGU15
100 1-1/4 SAFJ10-S-04-GG-S 18 SAFJ10S04 JMS JGL15 JGU15
100 1-1/2 SAFJ10-S-04-GG-S1 18 SAFJ10S04 JMS1 JGL15 JGU15
90° STANCHION 35 1-1/4 SAFJ03-S-04-GG-L 15.5 SAFJ03S04 JML JGL15 JGU15
MOUNT
35 1-1/2 SAFJ03-S-04-GG-L1 15.5 SAFJ03S04 JML1 JGL15 JGU15
50 1-1/4 SAFJ05-S-04-GG-L 16.5 SAFJ05S04 JML JGL15 JGU15
50 1-1/2 SAFJ05-S-04-GG-L1 16.5 SAFJ05S04 JML1 JGL15 JGU15
70 1-1/4 SAFJ07-S-04-GG-L 17.5 SAFJ07S04 JML JGL15 JGU15
70 1-1/2 SAFJ07-S-04-GG-L1 17.5 SAFJ07S04 JML1 JGL15 JGU15
100 1-1/4 SAFJ10-S-04-GG-L 19.5 SAFJ10S04 JML JGL15 JGU15
100 1-1/2 SAFJ10-S-04-GG-L1 19.5 SAFJ10S04 JML1 JGL15 JGU15
All fixtures are designed for Medium Base lamps, with the lamp mounted in base-up position.
➀
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page
Refer to Certification Guide to determine suitability of individual fixture.
238
HIGH PRESSURE SODIUM • METAL HALIDE
SAFJ Series
Hazardous Locations • Class l, Division 2, Class ll, Class lll • UL 1598A • UL 844 • Wet Locations • CUL
240
HIGH PRESSURE SODIUM • METAL HALIDE
SAFJ Series
Hazardous Locations • Class l, Division 2, Class ll, Class lll • UL 1598A • UL 844 • Wet Locations • CUL
Accessories
Conduit Shipping Reflectors, Globe, Shipping
Catalog Catalog No. Description Weight
Outlet Boxes Hub Size Weight Guard and Photocells
No. (Lbs.)
(In.) (Lbs.)
Rigid Pendant Dome Reflector 0.8
Standard
Dome
JMP 3/4 3.0 JD15 Reflector
Molded
Polycarbonate
Shipping
Catalog Weight
JMS1 1 1/2 5.0
Fuse Kit No. Description (Lbs.)
242
SXP SERIES S
X
P
HID Lighting for Explosion Proof, Hazardous and Hostile Locations
713.943.0340 | azz.com/rigalite
SXP SERIES
HID Lighting for Hazardous and Hostile Locations
Electro-Polished stainless
steel wire guard.
42
HID
SXP Series
Explosion Proof • UL 844 & 1598A • CUL • Marine Outside Type • Factory Sealed
SXP 15-S-04-GG-P-XX
1 2 3 4 5 6 7
Certification Guide
SXP SERIES Page 1 of 2
CERTIFICATION GUIIDE
CLASS II
TYPE LAMP
AMBIENT CLASS I DIVISION 1 SUPPLY WIRE PAINT
MODEL MOUNT TEMPERATURE DIVISION 1 GROUPS E, SUITABLE UL 1598A SPRAY
(*) WATTS
°C GROUPS C & D F & G, TEMPERATURE BOOTH
CLASS III °C
SXP40S HPS 400 P,C,W 40 T3C -- 90 YES NO
SXP40S HPS 400 S,T 40 T3A -- 90 YES NO
OUTLET BOXES
SXPP
GLOBES
SXP25GL SXP40GL
GUARDS
SXP25WG SGU40SS
REFLECTORS
REFLECTORS
TRUNNION MOUNT
HID
SXP Series
Explosion Proof • UL 844 & 1598A • CUL • Marine Outside Type • Factory Sealed
SXP-15-S-04-GG-T-XX
1 2 3 4 5 6 7
4 BALLAST VOLTAGE
04 = Multi-Tap
12 = 120V 60HZ
20 = 208V 60HZ
22 = 220V 50HZ
24 = 240V 60HZ
27 = 277V 60HZ
34 = 347V 60HZ
48 = 480V 60HZ
HID
SXP SeriesSeries
SXP Floodlight
Explosion Proof • UL 844 & 1598A • CUL • Marine Outside Type • Factory Sealed
Certification Guide
SXP FLOODLIGHT SERIES Page 1 of 2
CERTIFICATION GUIIDE
SUPPLY
AMBIENT CLASS I WIRE
LAMP
MODEL TYPE (*) MOUNT TEMPERATURE DIVISION 1 SUITABLE UL 1598A
WATTS
°C GROUPS C & D TEMPERA
TURE °C
SXP40S HPS 400 T 40 T3A 90 YES
713.943.0340 | azz.com/rigalite
SXPJ SERIES
HID & Fluorescent Lighting for Hazardous and Hostile Locations
Available in fi ve mounting
styles: pendant, ceiling,
90º wall bracket, 25º stan- Ballast housing, outlet boxes
chion mount and trunnion and lens retaining rings
Wireless electromechanical mount. are high strength corrosion
connector block for quick, resistant copper free (less
safe fi xture removal and than 0.4%) aluminum.
bench-top maintenance.
Electro-Polished stainless
steel wire guard.
SXPJ 15-S-04-GG-P-XX
1 2 3 4 5 6 7
1 BASIC SERIES
Class I, Division 1, Groups C & D 5 GLOBE & GUARD
GG = Globe and Guard
Class II, Division 1, Groups E, F & G*
G = Globe only
Class III
Class I, Zone 1, Groups IIA & IIB 6 MOUNTING STYLE
Factory Sealed P = 3/4" Pendant Mount
UL1598, UL1598A, & UL844 P1 = 1" Pendant Mount
CUL C = 3/4" Ceiling Mount
NEMA Type 4X, IP66 C1 = 1" Ceiling Mount
W = 3/4" Wall Mount
W1 = 1" Wall Mount
S = 1-1/4" Stanchion Mount
2 LAMP CURRENT/LAMP WATTAGE
26 = 26 Watt
S1 = 1-1/2" Stanchion Mount
T = Trunnion Mount*
32 = 32 Watt
42 = 42 Watt
50 = 50 Watt
7 OPTIONS1
FB1 = Single Fuse Block ² ³
52 = 52 Watt
FB2 = Double Fuse Block ² ³
64 = 64 Watt
EM = Emergency Battery Backup
07 = 70 Watt
w/ AC Ballast (CFL Only)
84 = 84 Watt
EMO = Emergency Only Battery
10 = 100 Watt
Backup w/o AC Ballast
15 = 150 Watt
(CFL Only)
17 = 175 Watt
PS = Pulse Start (for 150 & 175W MH Lamps)
BP = Ballast Protector
3 LAMP TYPE
H = Metal Halide (Medium Base)
SC = Safety Cable & Eye Bolt
EB = Eye Bolt Only
(50, 70, 100, 150 & 175 Watt)
S = High Pressure Sodium (Medium Base)
(50, 70, 100 & 150 Watt)
F = Compact Fluorescent 1 Consult factory for pricing.
(26, 32, 42, 52, 64 & 84 Watt) 2 Not available with multi-tap ballast unless voltage is specified.
4 BALLAST VOLTAGE When installed, one fuse block is provided for 120,277V and
two fuse blocks are provided for 208, 220, 240 & 480V.
04 = 120/208/240/277V 60HZ Fuse not included.
22 = 220V/240V 50HZ 3 Fuse option not available for marine listed fixtures.
48 = 480V 60HZ
U = 120 thru 277V 50/60HZ
(compact fluorescent)
* Trunnion mount not approved for use in Class II environments
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
HID• COMPACT FLUORESCENT
SXPJ Series
Explosion Proof • UL 844 & 1598A • Marine Outside Type • Factory Sealed
Certification Guide
SXPJ SERIES
CERTIFICATION GUIIDE
Page 1 of 1
CLASS I CLASS II
AMBIENT CLASS I SUPPLY WIRE
TYPE LAMP ZONE 1 DIVISION 1 UL
MODEL MOUNT TEMPERATURE DIVISION 1 SUITABLE
(*) WATTS GROUPS GROUPS E, 1598A
°C GROUPS C & D F & G, TEMPERATURE
IIA & IIB
CLASS III °C
SXPJ15S HPS 150 P,C,W,S,T 40 T4 T4 -- 90 YES
SXPJ15S HPS 150 P,C,W,S,T 55 T4 T4 -- 90 YES
Pendant
SXPP Mount
Ballast Housing
SXPJ HOUSING Ballast Housing
SXPJ HOUSING
SXP25GL
Prismatic Glass Globe
Wire Guard
SXP25WG
StandardSR40D
Dome Reflector 30° Angle
SR40AReflector HighSR40HB
Bay Reflector
(Fiberglass Reinforced Polyester) (Fiberglass Reinforced Polyester)
HID• COMPACT FLUORESCENT
SXPJ Series
Explosion Proof • UL 844 & 1598A • Marine Outside Type • Factory Sealed
CEILING
50 S68 3/4 SXPJ05-S-04-GG-C SXPJ05-S-48-GG-C SXPJ05-S-22-GG-C 36.5
50 S68 1 SXPJ05-S-04-GG-C1 SXPJ05-S-48-GG-C1 SXPJ05-S-22-GG-C1 36.5
70 S62 3/4 SXPJ07-S-04-GG-C SXPJ07-S-48-GG-C SXPJ07-S-22-GG-C 36.5
70 S62 1 SXPJ07-S-04-GG-C1 SXPJ07-S-48-GG-C1 SXPJ07-S-22-GG-C1 36.5
100 S54 3/4 SXPJ10-S-04-GG-C SXPJ10-S-48-GG-C SXPJ10-S-22-GG-C 39
100 S54 1 SXPJ10-S-04-GG-C1 SXPJ10-S-48-GG-C1 SXPJ10-S-22-GG-C1 39
150 S55 3/4 SXPJ15-S-04-GG-C SXPJ15-S-48-GG-C SXPJ15-S-22-GG-C 39
150 S55 1 SXPJ15-S-04-GG-C1 SXPJ15-S-48-GG-C1 SXPJ15-S-22-GG-C1 39
WALL
50 S68 3/4 SXPJ05-S-04-GG-W SXPJ05-S-48-GG-W SXPJ05-S-22-GG-W 38.5
50 S68 1 SXPJ05-S-04-GG-W1 SXPJ05-S-48-GG-W1 SXPJ05-S-22-GG-W1 38.5
70 S62 3/4 SXPJ07-S-04-GG-W SXPJ07-S-48-GG-W SXPJ07-S-22-GG-W 38.5
70 S62 1 SXPJ07-S-04-GG-W1 SXPJ07-S-48-GG-W1 SXPJ07-S-22-GG-W1 38.5
100 S54 3/4 SXPJ10-S-04-GG-W SXPJ10-S-48-GG-W SXPJ10-S-22-GG-W 41
100 S54 1 SXPJ10-S-04-GG-W1 SXPJ10-S-48-GG-W1 SXPJ10-S-22-GG-W1 41
150 S55 3/4 SXPJ15-S-04-GG-W SXPJ15-S-48-GG-W SXPJ15-S-22-GG-W 41
150 S55 1 SXPJ15-S-04-GG-W1 SXPJ15-S-48-GG-W1 SXPJ15-S-22-GG-W1 41
STANCHION ★
50 S68 1-1/4 SXPJ05-S-04-GG-S SXPJ05-S-48-GG-S SXPJ05-S-22-GG-S 35.5
50 S68 1-1/2 SXPJ05-S-04-GG-S1 SXPJ05-S-48-GG-S1 SXPJ05-S-22-GG-S1 35.5
70 S62 1-1/4 SXPJ07-S-04-GG-S SXPJ07-S-48-GG-S SXPJ07-S-22-GG-S 35.5
70 S62 1-1/2 SXPJ07-S-04-GG-S1 SXPJ07-S-48-GG-S1 SXPJ07-S-22-GG-S1 35.5
100 S54 1-1/4 SXPJ10-S-04-GG-S SXPJ10-S-48-GG-S SXPJ10-S-22-GG-S 38
100 S54 1-1/2 SXPJ10-S-04-GG-S1 SXPJ10-S-48-GG-S1 SXPJ10-S-22-GG-S1 38
150 S55 1-1/4 SXPJ15-S-04-GG-S SXPJ15-S-48-GG-S SXPJ15-S-22-GG-S 38
150 S55 1-1/2 SXPJ15-S-04-GG-S1 SXPJ15-S-48-GG-S1 SXPJ15-S-22-GG-S1 38
CEILING
26 GX24Q-3 3/4 SXPJ26-F-U-GG-C-EM SXPJ26-F-U-GG-C-EMO 40.5
26 GX24Q-3 1 SXPJ26-F-U-GG-C1-EM SXPJ26-F-U-GG-C1-EMO 40.5
WALL
26 GX24Q-3 3/4 SXPJ26-F-U-GG-W-EM SXPJ26-F-U-GG-W-EMO 42.5
26 GX24Q-3 1 SXPJ26-F-U-GG-W1-EM SXPJ26-F-U-GG-W1-EMO 42.5
TRUNNION ★
CEILING
52 GX24Q-3 3/4 SXPJ52-F-U-GG-C-EM SXPJ52-F-U-GG-C-EMO 40.5
52 GX24Q-3 1 SXPJ52-F-U-GG-C1-EM SXPJ52-F-U-GG-C1-EMO 40.5
WALL
52 GX24Q-3 3/4 SXPJ52-F-U-GG-W-EM SXPJ52-F-U-GG-W-EMO 42.5
52 GX24Q-3 1 SXPJ52-F-U-GG-W1-EM SXPJ52-F-U-GG-W1-EMO 42.5
TRUNNION ★
SXPJ-15-S-04-GG-T-XX
1 2 3 4 5 6 7
1 BASIC SERIES
Class I, Division 1, Groups C & D 5 GLOBE & GUARD
GG = Globe and Guard
Class II, Division 1, Groups E, F & G*
G = Globe only
Class III
Class I, Zone 1, Groups IIA & IIB 6 MOUNTING STYLE
Factory Sealed T = Trunnion Mount*
UL 1598, UL1598A, & UL 844
CUL OPTIONS1
NEMA Type 4X, IP66 FB1 = Single Fuse Block ² ³
FB2 = Double Fuse Block ² ³
EM = Emergency Battery Backup
w/ AC Ballast (CFL Only)
2 LAMP CURRENT/LAMP WATTAGE
26 = 26 Watt
EMO = Emergency Only Battery
Backup w/o AC Ballast
32 = 32 Watt
(CFL Only)
42 = 42 Watt
52 = 52 Watt
7 PS = Pulse Start (for 150 & 175W MH Lamps)
BP = Ballast Protector
64 = 64 Watt
SC = Safety Cable & Eye Bolt
84 = 84 Watt
EB = Eye Bolt Only
05 = 50 Watt
07 = 70 Watt
10 = 100 Watt
15 = 150 Watt
17 = 175 Watt 1 Consult factory for pricing.
2 Not available with multi-tap ballast unless voltage is specified.
3 LAMP TYPE
H = Metal Halide (Medium Base)
When installed, one fuse block is provided for 120,277V and
two fuse blocks are provided for 208, 220, 240 & 480V.
Fuse provided
(50, 70, 100, 150 & 175 Watt) 3 Fuse option not available for marine listed fixtures.
Certification Guide
SXP FLOODLIGHT SERIES Page 1 of 2
CERTIFICATION GUIIDE
SUPPLY
AMBIENT CLASS I WIRE
LAMP
MODEL TYPE (*) MOUNT TEMPERATURE DIVISION 1 SUITABLE UL 1598A
WATTS
°C GROUPS C & D TEMPERA
TURE °C
SXP40S HPS 400 T 40 T3A 90 YES
70 M98 3/4
SXPJ07-H-04-GG-T SXPJ07-H-48-GG-T-PS SXPJ07-H-22-GG-T-PS 37.5
4 GX24Q4 3/4
84 GX24Q4 3/4 SXPJ84-F-U-GG-T 41.5
HID• COMPACT FLUORESCENT
SXPJ Floodlight Series
Explosion Proof • UL 844 & 1598A • Marine Outside Type • Factory Sealed
One-piece copper-free
cast aluminum lamp
and ballast housing with
baked on bronze
polyester powder coat
finish.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
www.rigalite.com
METAL HALIDE • HIGH PRESSURE SODIUM
AFL Series
Hazardous Locations • Cast Aluminum • Class I, Divsion 2 • UL 1598A, 844 • CUL • Wet Locations
Shown with optional visor.
Lamp Shipping
Fixture Type Figure Number Wattage Voltage Catalog Number Weight (Lbs.)
Multi-Tap* AFL07-S-04-T-66 ➀➁➂ 34.0
70
480V/60HZ AFL07-S-48-T-66 ➀➁➂ 34.0
Multi-Tap* AFL110-S-04-T-66 ➀➁➂ 34.0
100
480V/60HZ AFL110-S-48-T-66 ➀➁➂ 34.0
Multi-Tap* AFL115-S-04-T-66 ➀➁➂ 34.0
1 150
High Pressure 480V/60HZ AFL115-S-48-T-66➀➁➂ 34.0
Sodium Multi-Tap* AFL125-S-04-T-66➀➁➂ 37.0
250
480V/60HZ AFL125-S-48-T-66 ➀➁➂ 36.5
Multi-Tap* AFL140-S-04-T-66 ➀➁➂ 39.5
400
480V/60HZ AFL140-S-48-T-66 ➀➁➂ 39.0
Multi-Tap* AFL5100-S-04-T-76 ➀➁ 65.5
5 1000
480V/60HZ AFL5100-S-48-T-76 ➀➁ 65.0
Multi-Tap* AFL117-H-04-T-66-PS ➀➁ 35.0
175
480V/60HZ AFL117-H-48-T-66-PS ➀➁ 35.0
Multi-Tap* AFL125-H-04-T-66-PS ➀➁➂ 35.0
250
480V/60HZ AFL125-H-48-T-66-PS➀➁➂ 34.0
1
Multi-Tap* AFL132-H-04-T-66-PS ➀➁➂ 39.5
320
Metal 480V/60HZ AFL132-H-48-T-66-PS➀➁➂ 39.0
Halide Multi-Tap* AFL135-H-04-T-66 ➀➁➂ 36.5
350
480V/60HZ AFL135-H-48-T-66 ➀➁➂ 36.5
Multi-Tap* AFL140-H-04-T-66 ➀➁➂ 36.5
400
480V/60HZ AFL140-H-48-T-66 ➀➁➂ 36.5
Multi- Tap* AFL2100-H-04-T-66 ➁ 77.0
2 1000
480V/60HZ AFL2100-H-48-T-66 ➁ 77.0
*120/208/240/277V 60HZ
➀ Class I, Division 2, UL 844 Listed
➁ UL 1598A Listed
➂ CUL
METAL HALIDE • HIGH PRESSURE SODIUM
AFL Series
Hazardous Locations • Cast Aluminum • Class I, Divsion 2 • UL 1598A, 844 • CUL • Wet Locations
Certification Guide
Ambient Class I, Division 2 Supply Wire Suitable
Model Lamp
Temperature °C Groups A,B, C & D Temperature °C
AFL140 MH 55 T1 (350°C) 105
AFL125 MH 55 T1 (325°C) 90
AFL117 MH 55 T1(325°C) 90
AFL115 MH 55 T1 (325°C) 90
AFL140 HPS 55 T1(450°C) 105
AFL125 HPS 55 T1 (350°C) 90
AFL115 HPS 55 T1 (350°C) 90
AFL5100 HPS 25 T1 90
NOTE:
Accessories FLB-3 and FLB-5 fit 2 in. to 2-1/2 in. pipe size (2-3/8 in. to 2-7/8 in. O.D.)
www.rigalite.com
METAL HALIDE • HIGH PRESSURE SODIUM
AFL Series
Hazardous Locations • Cast Aluminum • Class I, Divsion 2 • UL 1598A, 844 • CUL • Wet Locations
AFL1 AFL2
FIGURE 1 FIGURE 2
AFL5
FIGURE 3
713.943.0340 | azz.com/rigalite
SSFN SERIES
Stainless Steel Flood Lighting for Hazardous Locations
Heavy duty
trunnion mount.
SSFN 40-S-04-XX
1 2 3 4 5
1 BASIC SERIES
SSFN Stainless Flood Light
4 VOLTAGE/FREQUENCY
Class I, Division 2 Groups A, B, C & D 04 = Multi-tap (120, 208, 220, 240 & 277V)
Class I, Zone 2 12 = 120V 60 HZ
UL 844 Hazardous Locations 20 = 208V 60 HZ
UL 1598 Wet Locations 22 = 220 thru 240V 50 HZ
UL 1598A Marine Outside Type 24 = 240V 60 HZ
CUL 27 = 277V 60 HZ
AEx nR II, Ex nR II- T3 34 = 347V 60 HZ
Restricted Breathing (400W Max.) 48 = 480V 60 HZ
IP66
5 OPTIONS1
Q = Auxiliary Quartz Relay2
2 LAMP CURRENT/LAMP WATTAGE
07 = 70 Watt QTD = Auxiliary Quartz Relay Hot & Cold Start2
10 = 100 Watt PC = Photo Cell3
15 = 150 Watt FB1 = Single Fuse Block4,5
FB2 = Double Fuse Block4,5
17 = 175 Watt
25 = 250 Watt PL = Clear Acrylic Shield
32 = 320 Watt R = Instant Restrike (HPS Only- up to 150W)
35 = 350 Watt 316 = Type 316 Stainless Steel Body
40 = 400 Watt PS = Pulse Start6
LS = Lamp Support
100 = 1000 Watt
V = Visor7
LAMP TYPE (MOGUL BASE) 1 Consult factory for pricing.
S = High Pressure Sodium
3 (100, 150, 200, 250 & 400 Watt)
2
Limited to 175W Maximum HID Lamp
3 Not suitable for hazardous locations.
H = Metal Halide 4 Not available with multi-tap ballast unless incoming voltage is specified.
When installed, one fuse block/fuse holder is provided for 120, 277V. Fuse not
(100, 175, 250, 320, 350, included. Option not available for marine listed fixtures.
400 & 1000 Watt) 5 Not available with multi-tap ballast unless incoming voltage is specified.
When installed, two fuse blocks/fuse holders are provided for 208, 240, 347 and
480V. Fuse not included. Option not available for marine listed fixtures.
6 Use universal or appropriate position oriented lamp.
7 Available for fixtures up to 400W.
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
METAL HALIDE • HIGH PRESSURE SODIUM
SSFN Series
Hazardous Locations • Stainless Steel • Class I, Division 2 • UL 1598A, 844 • CUL • AEx nR II, Ex nR II , T3
* 120/208/240/277V 60 HZ
* 120/208/240/277V 60HZ
METAL HALIDE • HIGH PRESSURE SODIUM
SSFN Series
Hazardous Locations • Stainless Steel • Class I, Division 2 • UL 1598A, 844 • CUL • AEx nR II, Ex nR II , T3
D
B B D
3.855
2.375
.56 DIA HOLE
TYP. 3 PLACES
2.00
4.00
3/4” NPT Hub at bottom on all models
1.75
3.50
Dimensions Effective
Projected
Figure Number A B C D Area (EPA)
1 17.00 17.00 9.00 14.00 2.02 sq. ft.
2 22.00 19.00 9.00 16.00 2.92 sq. ft.
3 27.00 27.00 12.00 24.00 5.20 sq. ft.
Certification Guide
Supply Wire
Ambient Class I, Division 2 Class I, Zone 2,
Model Lamp Housing Size Suitable
Temperature Groups A, B, C & D AEx nR II, Ex nR II
Temperature °C
°C
SSFN100 MH/ HPS Fig. 3 (27 X 27) 40 T1 - 125
SSFN40 MH/HPS Fig. 2 (22 X 19) 40 T1 T3 125
SSFN35 MH Fig. 2 (22 X 19) 40 T1 T3 125
SSFN32 MH Fig. 2 (22 X 19) 40 T1 T3 125
SSFN25 MH/HPS Fig. 2 (22 X 19) 55 T1 T3 125
SSFN17 MH Fig. 2 (22 X 19) 55 T2 T3 125
SSFN17Q MH Fig. 2 (22 X 19) 40 591°C - 125
SSFN15 HPS Fig. 2 (22 X 19) 55 T1 T3 125
SSFN15 HPS Fig. 1 (17 X 17) 40 T2B T3 125
SSFN15Q HPS Fig. 1 (17 X 17) 40 550°C - 125
SSFN10 HPS Fig. 1 (17 X 17) 40 T2 T3 125
SSFN10 HPS Fig. 1 (17 X 17) 40 591°C - 125
Mounting Restriction:
30º either side of vertical lamp- base down
METAL HALIDE • HIGH PRESSURE SODIUM
SSFN Series
Hazardous Locations • Stainless Steel • Class I, Division 2 • UL 1598A, 844 • CUL • AEx nR II, Ex nR II , T3
Accessories
One-piece copper-free
cast aluminum lamp
and ballast housing with
baked on polyester
powder coat finish
EFL 15-S-04-T-76-XX
1 2 3 4 5 6 7
1 BASIC SERIES
EFL Series Floodlight
4 BALLAST VOLTAGE
04 = Multi-Tap
UL 1598 Wet & Damp Locations 12 = 120V 60 HZ
20 = 208V 60 HZ
2 LAMP CURRENT/LAMP WATTAGE
07 = 70 Watt
22 = 220/240V 50 HZ
24 = 240V 60 HZ
10 = 100 Watt 27 = 277V 60 HZ
15 = 150 Watt 34 = 347V 60 HZ
17 = 175 Watt 48 = 480V 60 HZ
25 = 250 Watt
32 = 320 Watt
35 = 350 Watt
5 MOUNTING
T = Trunnion
40 = 400 Watt
6 BEAM SPREAD
3 LAMP TYPE (MOGUL BASE)
S = High Pressure Sodium
76 = 7H X 6V
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
HIGH PRESSURE SODIUM • METAL HALIDE
EFL Series
UL 1598 Wet & Damp Locations
Accessories
Safety Cable
Wall or Pole Mounting Kit Pole Top Mounting Kit Catalog Number: 10128R
Wall or Pole Mount, Includes (2) U-Bolts Gasket Wiring Compartment Adapts Horizontal Shipping Weight: 1.0 lbs.
Catalog Number: FLB-3 or Vertical Mounting Yokes, Includes (3) Set
Shipping Weight: 3.6 lbs. Screws,
Catalog Number: FLB-5
Shipping Weight: 3.2 lbs.
NOTE:
FLB-3 and FLB-5 fit 2 in. to 2-1/2 in. pipe size (2-3/8 in. to 2-7/8 in. O.D.)
NOTES
SAF SERIES S
A
Hazardous Location Mogul Base HID and Compact Fluorescent
F
• Class I, Division 2, Groups A, B, C & D
• Class II, Division 1 & 2, Groups E, F & G
• Class III
• Zone 2, Groups IIA, IIB & IIC
• UL 844 Hazardous Locations
• UL 1598 Wet Locations
• UL 1598A Marine Outside Type
• UL 924 Emergency Lighting
• NEMA 3R, 4X
• IP66
• CSA Certified
• ABS Type Approved
• Restricted Breathing (175W Max.)
• AExnR II, ExnR II & T3
• Enclosed & Gasketed
713.943.0340 | azz.com/rigalite
SAF SERIES
Hazardous Location Mogul Base HID and Compact Fluorescent
3
• Reflectors cannot be added. Lamp to be 100W
LAMP TYPE1 DC bayonet base.
• Available with maximum 150W HPS & 250W MH
S = High Pressure Sodium lamp.
(70, 100, 150, 200, 250, 400 Watt) 4 Not available with multi-tap ballast unless
Certification Guide
SIMULTANEOUS
CLASS I, DIV 2 GROUPS A,B,C,D CLASS II & III PRESENCE
SUPPLY
WIRE
GLOBE GLOBE GLOBE GLOBE UL 1598A SUITABLE
MODEL AMBIENT ° C GUARD W/REFL REFRACTOR GROUPS GUARD REFRACTOR GUARD REFRACTOR OUTDOOR CSA TEMP °C
SAF05S 40 T3 T3 T3B E,F,G T4A T6 T2 T2B YES YES 90
SAF05S 55 T3 T3 - - - - - - YES YES 90
SAF05S 65 T2D T2D T2D - - - - - YES YES 110
SAF07S 40 T3 T3 T3B E,F,G T4A T6 T3 T3C YES YES 90
SAF07S 55 T3 T3 - - - - - - YES YES 90
SAF07S 65 T2D T2D T2D - - - - - YES YES 110
SAF10S 40 T2D T2D T3 E,F,G T3C T6 T2B T3 YES YES 90
SAF10S 55 T2D T2D - - - - - - YES YES 90
SAF10S 65 T2C T2C - - - - - - YES YES 110
SAF15S 40 T2B T2B T2C E,F ** T3 - T2 T2B YES YES 90
SAF15S 40 T2B T2B T2C E,F,G - T4A - - YES YES 90
SAF15S 55 T2B T2B - - - - - - YES YES 90
SAF15S 65 T2A T2A - - - - - - YES YES 110
SAF25S 40 T1 (350) T1 (350) T1(350) E,F,G T3C T3C T1 (350) T1 (350) YES YES 105
SAF25S 55 T1 (350) T1 (350) - - - - - - YES YES 110
SAF25S 65 T1 T1 - - - - - - YES YES 125
SAF40S 40 T1 T1 T1 E,F,G - T3B - - YES YES 110
SAF10H 40 T2B T2B T2C E,F,G - T4 - - YES YES 125
SAF15H 40 T2 T2 T2 E,F,G - T4 - T2 YES YES 125
SAF15H 55 T2 T2 - - - - - - YES YES 125
SAF17H 40 T2 T2 T2 E,F,G - T4 - T2 YES YES 125
SAF17H 55 T2 T2 - - - - - - YES YES 125
SAF25H 40 T1 T1 T2 E,F,G - T4 - T2 YES YES 110
SAF40H 40 T1 T1 T1 E,F,G - T3B - - YES YES 110
SAFR05S 40 - - T3 E,F,G - T4A - T3 YES YES 90
SAFR05S 55 - - T3 - - - - - YES YES 90
SAFR07S 40 - - T3 E,F,G - T4A - T3 YES YES 90
SAFR07S 55 - - T3 - - - - - YES YES 90
SAFR10S 40 - - T2D E,F,G - T3C - T2B YES YES 90
SAFR10S 55 - - T2D - - - - - YES YES 90
SAFR15S 40 - - T2B E,F - T3 - T2 YES YES 90
SAFR15S 55 - - T2B - - - - - YES YES 90
SAFR10H 40 - - T2B - - - - - YES YES 105
SAFR10H 55 - - T2 - - - - - YES YES 125
SAFR17H 40 - - T2 - - - - - YES YES 105
SAFR17H 55 - - T2 - - - - - YES YES 125
SAF26F 40 T3 T3 T3B E,F,G T4A T6 T3 T3C YES - 75
SAF32F 40 T2B T2B T2B E,F,G T4A T4 - - YES - 75
SAF42F 40 T2A T2A T2A E,F,G T4A T4 - - YES - 75
SAF52F 40 T2B T2B T2B E,F,G T4A T4 - - YES - 75
SAF64F 40 T2B T2B T2B E,F,G T4A T4 - - YES - 75
SAF84F 40 T2A T2A T2A E,F,G T4A T4 - - YES - 75
*GROUPS E & F ONLY FOR STANCHION MOUNT. GROUPS E, F, & G FOR ALL OTHER MOUNTS.
NOTE: ALL SAF SERIES FIXTURES WITH GLOBE AND GUARD RATED 175W MAXIMUM AT 40° C ARE ADDITIONALLY LISTED FOR
CLASS I ZONE 2 AEx OR EX nR II AND ARE MARKED WITH THE OPERATING TEMPERATURE 160° C OR CODE T3
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
High Pressure Sodium with Globe and Guard 70-400 Watts (continued)
(Lamps not included)
High Pressure Sodium with Threaded Refractor and Guard 70-400 Watts
(Lamps not included)
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
High Pressure Sodium with Threaded Refractor and Guard 70-400 Watts (continued)
(Lamps not included)
25° STANCHION MOUNT 70 1-1/4 SAFR07-S-04-T5G-S 31.6 SAFR07S04 SMS SRT25GL SXP25WG
70 1-1/2 SAFR07-S-04-T5G-S1 31.6 SAFR07S04 SMS1 SRT25GL SXP25WG
90° STANCHION MOUNT 70 1-1/4 SAFR07-S-04-T5G-L 31.6 SAFR07S04 SML SRT25GL SXP25WG
70 1-1/2 SAFR07-S-04-T5G-L1 31.6 SAFR07S04 SML1 SRT25GL SXP25WG
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Catalog Nos. shown are for fixtures with IES Type V closed bottom glass refractors, for other type refractors, refer to Catalog Number Logic page.
④ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture. Fixtures with Refractors are not suitable to ordered with reflectors.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
High Pressure Sodium with Refractor and Guard 70-400 Watts (continued)
(Lamps not included)
Conduit Catalog③ Shipping CONSISTS OF
Lamp➀
Mounting Style Size Number Weight Ballast Outlet
Watts Refractor③ Guard
(in.) 120/208/240/277V➁ (lbs.) Housing➁ Box
WALL MOUNT 70 1-14 SAF07-S-04-R5-G-W 35.9 SAF07S04 SMW SRE25GL SGU25W
70 1-1/2 SAF07-S-04-R5-G-W1 35.9 SAF07S04 SMW1 SRE25GL SGU25W
150④
150 1-1/4 SAF15-S-04-R5-G-L 35.3 SAF15S04 SML SRE25GL SGU25W
150④
150 1-1/2 SAF15-S-04-R5-G-L1 35.3 SAF15S04 SML1 SRE25GL SGU25W
250 1-1/4 SAF25-S-04-R5-G-L 47.1 SAF25S04 SML SRE45GL SGU25W
250 1-1/2 SAF25-S-04-R5-G-L1 47.1 SAF25S04 SML1 SRE45GL SGU25W
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
Metal Halide with Threaded Refractor and Guard 70-400 Watts (continued)
(Lamps not included)
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Fixtures are for use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with 100V (ANSI S56) lamp, consult factory.
Refer to Certification Guide to determine suitability of individual fixture.
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Catalog Nos. shown are for fixtures with IES Type V closed bottom glass refractors, for other type refractors, refer to Catalog Number Logic page.
Refer to Certification Guide to determine suitability of individual fixture. Fixtures with Refractors are not suitable to ordered with reflectors.
Fixtures with Refractors are not suitable to be ordered with reflectors.
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
To order fixtures with Auxiliary Quartz Circuit - add suffix “Q” to the Catalog No. (100 watt quartz lamp not included).
➀ All fixtures are designed for Mogul Base lamps, with the lamp mounted in base-up position.
➁ Fixtures and housings are with Multi-Tap ballast. For other ballast voltages, refer to Catalog Number Logic page.
③ Catalog Nos. shown are for fixtures with IES Type V closed bottom glass refractors, for other type refractors, refer to Catalog Number Logic page.
➀ 52 (2-26W Lamps); 64 (2-32W Lamps); 84 (2-42W Lamps) Fixtures with Refractors are not suitable to be ordered with reflectors.
➁ 120V thru 277V AC, 50/60HZ; 125V DC
➂ Catalog Nos. shown are for fixtures with IES Type V closed bottom glass refractors, for other type refractors, refer to Catalog Number Logic
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
➀ 52 (2-26W Lamps); 64 (2-32W Lamps); 84 (2-42W Lamps) Fixtures with Refractors are not suitable to be ordered with reflectors.
➁120V thru 277V AC, 50/60HZ; 125V DC
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
➀ 52 (2-26W Lamps); 64 (2-32W Lamps); 84 (2-42W Lamps) Fixtures with Refractors are not suitable to be ordered with reflectors.
➁ 120V thru 277V AC, 50/60HZ; 125V DC
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
Fluorescent Emergency
• Emergency illumination meets OSHA, Life Safety Code (NFPA 101),
and National Electric Code (NFPA 70) requirements
• Provides up to 700 lumens of initial light output in emergency mode
• Provides at least 90 minutes of illumination in emergency mode
• Sealed, maintenance free nickel cadmium batteries with a life
expectancy of 7-10 years
• Self contained unitized construction
• Starting temperature 0°C (32°F)
(Lamps included)
Conduit Shipping
Fixture Type Description Size Voltage➀ Catalog Number Weight
(In.) (Lbs.)
Stanchion/Pendant/Ceiling Mount 3/4 120v/60HZ SAF42-F-12-GG-C-EMO 22.2
Emergency (1) 42 Watt Fluorescent lamps 1 120v/60HZ SAF42-F-12-GG-C1-EMO 22.2
Only
Operation Wall Mount 3/4 120v/60HZ SAF42-F-12-GG-W-EMO 28.23
(1) 42 Watt Fluorescent lamps 1 120v/60HZ SAF42-F-12-GG-W1-EMO 28.23
Certification Guide
Class I, Division 2 Groups A,B, C, D Class II, Division 1, Class III Supply Wire
Ambient (When Used With) (When Used With) Suitable UL1598A
Model Lamp Watts
Temperature Globe w/ Temperature Outdoor
Globe Refractor Groups Globe Refractor
°C Reflector °C
SAF26F 40 26W T3 T3 T3B E,F,G T4A T6 90 YES
SAF32F 40 32W T2B T2B T2B E,F,G T4A T4 90 YES
SAF42F 40 42W T2D T2D T2D E,F,G T3C T4A 90 YES
SAF52F 40 52W (2 X 26W) T2B T2B T2B E,F,G T4A T4 90 YES
SAF64F 40 64W (2 X 32W) T2B T2B T2B E,F,G T4A T4 90 YES
SAF84F 40 84W (2 X 42W) T2A T2A T2A E,F,G T4A T4 90 YES
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
PENDANT MOUNT
with Threaded Glass Refractor and Guard
Accessories
Conduit Shipping
Catalog Hub Weight Shipping
OUTLET BOXES No. Size (In.) (Lbs.) Catalog Weight
RIGID PENDANT REFLECTORS➁ No. Description (Lbs.)
SMP 3/4 3.3
Standard Dome 2.0
Reflector
Fiberglass
SMP1 1 3.3 Reinforced
SR25D➀
Polyester
for use with
5-1/2 in. dia.
FLEXIBLE PENDANT
Globe
SMF 3/4 3.3
Standard Dome 3.0
Reflector
SMF1 1 3.3 Fiberglass
Reinforced
SR40D➀
Polyester
CEILING MOUNT for use with
7-3/4 in. dia.
SMC 3/4 4.1
Globe
① Not suitable for wall mount applications, fixtures with quartz option or with R2, R3 or
Refer to Certification Guide to determine suitability of individual fixture. R5 refractor
➁ Not suitable fixtures with quartz option or with R2, R3 or R5 refractor
HIGH PRESSURE SODIUM • METAL HALIDE • COMPACT FLUORESCENT
SAF Series
Hazardous Locations • Class I, Division 2 • Class II • Class III • UL 1598, 1598A, 844 • Wet Locations • CSA
Accessories
Shipping Shipping
Catalog Weight Catalog Weight
GUARDS No. Description (Lbs.) GLASS GLOBE No. Description (Lbs.)
.33 Heat and 4.0
Fiberglass Impact
Reinforced Resistant
Polycarbonate SGL25T Prismatic
SGU25P Guard for use Glass Globe
with 5-1/2 in. 250 Watt Max.
dia. Globe (5-1/2 in. dia.)
Shipping
Catalog
FUSE KIT Description Weight
No.
2.0 (Lbs.)
Stainless Steel
Guard for use
with 7-3/4 in.
SGU40SS Open fuse
dia. Globe
block kit- 600
SBF600 volt AC .06
maximum.
2.0
Wire Guard
for Glass Shipping
Refractors SAFETY CABLE Catalog No. Weight
SGU25W (R Type (Lbs.)
Refractors)
Accessories
Shipping Shipping
Catalog Weight GLASS Catalog Weight
PHOTO CELL KIT* No. Description (Lbs.) REFRACTORS No. Description (Lbs.)
Automatic on-off
SRE22GL IES Type II light
distribution
switch at (asymmetrical)
predetermined
light levels.
SPH25-120 120 volt only. .19
SRE23GL IES Type III light
distribution 11.0
REQUIRES
(asymmetrical)
FIELD
INSTALLATION.
713.943.0340 | azz.com/rigalite
SXPJ SERIES
HID & Fluorescent Lighting for Hazardous and Hostile Locations
Available in fi ve mounting
styles: pendant, ceiling,
90º wall bracket, 25º stan- Ballast housing, outlet boxes
chion mount and trunnion and lens retaining rings
Wireless electromechanical mount. are high strength corrosion
connector block for quick, resistant copper free (less
safe fi xture removal and than 0.4%) aluminum.
bench-top maintenance.
Electro-Polished stainless
steel wire guard.
SXPJ 15-S-04-GG-P-XX
1 2 3 4 5 6 7
1 BASIC SERIES
Class I, Division 1, Groups C & D 5 GLOBE & GUARD
GG = Globe and Guard
Class II, Division 1, Groups E, F & G*
G = Globe only
Class III
Class I, Zone 1, Groups IIA & IIB 6 MOUNTING STYLE
Factory Sealed P = 3/4" Pendant Mount
UL1598, UL1598A, & UL844 P1 = 1" Pendant Mount
CUL C = 3/4" Ceiling Mount
NEMA Type 4X, IP66 C1 = 1" Ceiling Mount
W = 3/4" Wall Mount
W1 = 1" Wall Mount
S = 1-1/4" Stanchion Mount
2 LAMP CURRENT/LAMP WATTAGE
26 = 26 Watt
S1 = 1-1/2" Stanchion Mount
T = Trunnion Mount*
32 = 32 Watt
42 = 42 Watt
50 = 50 Watt
7 OPTIONS1
FB1 = Single Fuse Block ² ³
52 = 52 Watt
FB2 = Double Fuse Block ² ³
64 = 64 Watt
EM = Emergency Battery Backup
07 = 70 Watt
w/ AC Ballast (CFL Only)
84 = 84 Watt
EMO = Emergency Only Battery
10 = 100 Watt
Backup w/o AC Ballast
15 = 150 Watt
(CFL Only)
17 = 175 Watt
PS = Pulse Start (for 150 & 175W MH Lamps)
BP = Ballast Protector
3 LAMP TYPE
H = Metal Halide (Medium Base)
SC = Safety Cable & Eye Bolt
EB = Eye Bolt Only
(50, 70, 100, 150 & 175 Watt)
S = High Pressure Sodium (Medium Base)
(50, 70, 100 & 150 Watt)
F = Compact Fluorescent 1 Consult factory for pricing.
(26, 32, 42, 52, 64 & 84 Watt) 2 Not available with multi-tap ballast unless voltage is specified.
4 BALLAST VOLTAGE When installed, one fuse block is provided for 120,277V and
two fuse blocks are provided for 208, 220, 240 & 480V.
04 = 120/208/240/277V 60HZ Fuse not included.
22 = 220V/240V 50HZ 3 Fuse option not available for marine listed fixtures.
48 = 480V 60HZ
U = 120 thru 277V 50/60HZ
(compact fluorescent)
* Trunnion mount not approved for use in Class II environments
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
HID• COMPACT FLUORESCENT
SXPJ Series
Explosion Proof • UL 844 & 1598A • Marine Outside Type • Factory Sealed
Certification Guide
SXPJ SERIES
CERTIFICATION GUIIDE
Page 1 of 1
CLASS I CLASS II
AMBIENT CLASS I SUPPLY WIRE
TYPE LAMP ZONE 1 DIVISION 1 UL
MODEL MOUNT TEMPERATURE DIVISION 1 SUITABLE
(*) WATTS GROUPS GROUPS E, 1598A
°C GROUPS C & D F & G, TEMPERATURE
IIA & IIB
CLASS III °C
SXPJ15S HPS 150 P,C,W,S,T 40 T4 T4 -- 90 YES
SXPJ15S HPS 150 P,C,W,S,T 55 T4 T4 -- 90 YES
Pendant
SXPP Mount
Ballast Housing
SXPJ HOUSING Ballast Housing
SXPJ HOUSING
SXP25GL
Prismatic Glass Globe
Wire Guard
SXP25WG
StandardSR40D
Dome Reflector 30° Angle
SR40AReflector HighSR40HB
Bay Reflector
(Fiberglass Reinforced Polyester) (Fiberglass Reinforced Polyester)
HID• COMPACT FLUORESCENT
SXPJ Series
Explosion Proof • UL 844 & 1598A • Marine Outside Type • Factory Sealed
CEILING
50 S68 3/4 SXPJ05-S-04-GG-C SXPJ05-S-48-GG-C SXPJ05-S-22-GG-C 36.5
50 S68 1 SXPJ05-S-04-GG-C1 SXPJ05-S-48-GG-C1 SXPJ05-S-22-GG-C1 36.5
70 S62 3/4 SXPJ07-S-04-GG-C SXPJ07-S-48-GG-C SXPJ07-S-22-GG-C 36.5
70 S62 1 SXPJ07-S-04-GG-C1 SXPJ07-S-48-GG-C1 SXPJ07-S-22-GG-C1 36.5
100 S54 3/4 SXPJ10-S-04-GG-C SXPJ10-S-48-GG-C SXPJ10-S-22-GG-C 39
100 S54 1 SXPJ10-S-04-GG-C1 SXPJ10-S-48-GG-C1 SXPJ10-S-22-GG-C1 39
150 S55 3/4 SXPJ15-S-04-GG-C SXPJ15-S-48-GG-C SXPJ15-S-22-GG-C 39
150 S55 1 SXPJ15-S-04-GG-C1 SXPJ15-S-48-GG-C1 SXPJ15-S-22-GG-C1 39
WALL
50 S68 3/4 SXPJ05-S-04-GG-W SXPJ05-S-48-GG-W SXPJ05-S-22-GG-W 38.5
50 S68 1 SXPJ05-S-04-GG-W1 SXPJ05-S-48-GG-W1 SXPJ05-S-22-GG-W1 38.5
70 S62 3/4 SXPJ07-S-04-GG-W SXPJ07-S-48-GG-W SXPJ07-S-22-GG-W 38.5
70 S62 1 SXPJ07-S-04-GG-W1 SXPJ07-S-48-GG-W1 SXPJ07-S-22-GG-W1 38.5
100 S54 3/4 SXPJ10-S-04-GG-W SXPJ10-S-48-GG-W SXPJ10-S-22-GG-W 41
100 S54 1 SXPJ10-S-04-GG-W1 SXPJ10-S-48-GG-W1 SXPJ10-S-22-GG-W1 41
150 S55 3/4 SXPJ15-S-04-GG-W SXPJ15-S-48-GG-W SXPJ15-S-22-GG-W 41
150 S55 1 SXPJ15-S-04-GG-W1 SXPJ15-S-48-GG-W1 SXPJ15-S-22-GG-W1 41
STANCHION ★
50 S68 1-1/4 SXPJ05-S-04-GG-S SXPJ05-S-48-GG-S SXPJ05-S-22-GG-S 35.5
50 S68 1-1/2 SXPJ05-S-04-GG-S1 SXPJ05-S-48-GG-S1 SXPJ05-S-22-GG-S1 35.5
70 S62 1-1/4 SXPJ07-S-04-GG-S SXPJ07-S-48-GG-S SXPJ07-S-22-GG-S 35.5
70 S62 1-1/2 SXPJ07-S-04-GG-S1 SXPJ07-S-48-GG-S1 SXPJ07-S-22-GG-S1 35.5
100 S54 1-1/4 SXPJ10-S-04-GG-S SXPJ10-S-48-GG-S SXPJ10-S-22-GG-S 38
100 S54 1-1/2 SXPJ10-S-04-GG-S1 SXPJ10-S-48-GG-S1 SXPJ10-S-22-GG-S1 38
150 S55 1-1/4 SXPJ15-S-04-GG-S SXPJ15-S-48-GG-S SXPJ15-S-22-GG-S 38
150 S55 1-1/2 SXPJ15-S-04-GG-S1 SXPJ15-S-48-GG-S1 SXPJ15-S-22-GG-S1 38
CEILING
26 GX24Q-3 3/4 SXPJ26-F-U-GG-C-EM SXPJ26-F-U-GG-C-EMO 40.5
26 GX24Q-3 1 SXPJ26-F-U-GG-C1-EM SXPJ26-F-U-GG-C1-EMO 40.5
WALL
26 GX24Q-3 3/4 SXPJ26-F-U-GG-W-EM SXPJ26-F-U-GG-W-EMO 42.5
26 GX24Q-3 1 SXPJ26-F-U-GG-W1-EM SXPJ26-F-U-GG-W1-EMO 42.5
TRUNNION ★
CEILING
52 GX24Q-3 3/4 SXPJ52-F-U-GG-C-EM SXPJ52-F-U-GG-C-EMO 40.5
52 GX24Q-3 1 SXPJ52-F-U-GG-C1-EM SXPJ52-F-U-GG-C1-EMO 40.5
WALL
52 GX24Q-3 3/4 SXPJ52-F-U-GG-W-EM SXPJ52-F-U-GG-W-EMO 42.5
52 GX24Q-3 1 SXPJ52-F-U-GG-W1-EM SXPJ52-F-U-GG-W1-EMO 42.5
TRUNNION ★
SXPJ-15-S-04-GG-T-XX
1 2 3 4 5 6 7
1 BASIC SERIES
Class I, Division 1, Groups C & D 5 GLOBE & GUARD
GG = Globe and Guard
Class II, Division 1, Groups E, F & G*
G = Globe only
Class III
Class I, Zone 1, Groups IIA & IIB 6 MOUNTING STYLE
Factory Sealed T = Trunnion Mount*
UL 1598, UL1598A, & UL 844
CUL OPTIONS1
NEMA Type 4X, IP66 FB1 = Single Fuse Block ² ³
FB2 = Double Fuse Block ² ³
EM = Emergency Battery Backup
w/ AC Ballast (CFL Only)
2 LAMP CURRENT/LAMP WATTAGE
26 = 26 Watt
EMO = Emergency Only Battery
Backup w/o AC Ballast
32 = 32 Watt
(CFL Only)
42 = 42 Watt
52 = 52 Watt
7 PS = Pulse Start (for 150 & 175W MH Lamps)
BP = Ballast Protector
64 = 64 Watt
SC = Safety Cable & Eye Bolt
84 = 84 Watt
EB = Eye Bolt Only
05 = 50 Watt
07 = 70 Watt
10 = 100 Watt
15 = 150 Watt
17 = 175 Watt 1 Consult factory for pricing.
2 Not available with multi-tap ballast unless voltage is specified.
3 LAMP TYPE
H = Metal Halide (Medium Base)
When installed, one fuse block is provided for 120,277V and
two fuse blocks are provided for 208, 220, 240 & 480V.
Fuse provided
(50, 70, 100, 150 & 175 Watt) 3 Fuse option not available for marine listed fixtures.
Certification Guide
SXP FLOODLIGHT SERIES Page 1 of 2
CERTIFICATION GUIIDE
SUPPLY
AMBIENT CLASS I WIRE
LAMP
MODEL TYPE (*) MOUNT TEMPERATURE DIVISION 1 SUITABLE UL 1598A
WATTS
°C GROUPS C & D TEMPERA
TURE °C
SXP40S HPS 400 T 40 T3A 90 YES
70 M98 3/4
SXPJ07-H-04-GG-T SXPJ07-H-48-GG-T-PS SXPJ07-H-22-GG-T-PS 37.5
4 GX24Q4 3/4
84 GX24Q4 3/4 SXPJ84-F-U-GG-T 41.5
HID• COMPACT FLUORESCENT
SXPJ Floodlight Series
Explosion Proof • UL 844 & 1598A • Marine Outside Type • Factory Sealed
High-temperature
Choice of incandescent lamps silicone gasket.
up to 150 W (A-21); or compact
fluorescent lamps (13W, 18W
and 26W).
RIG-A-LITE
COMPACT FLUORESCENT • INCANDESCENT
CVP Series
Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A • Wet Locations • CUL
CVP 15-I-24-HR-G-C-XX
1 2 3 4 5 6 7
1 BASIC SERIES 4 GLOBE
CVP Non-Metallic Series G = Soda Lime Clear Glass (Damp Location Only)
(i)* CVPH = Class I, Division 2, Groups A, B, C & D HR = Heat Resistant Soda Lime Glass
UL 844 Hazardous Locations P = Polycarbonate Prismatic Globe (75 Watt Max.)6
UL 1598A Marine Outside Type CP = Clear Polycarbonate (75 Watt Max.)6
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
www.rigalite.com
COMPACT FLUORESCENT • INCANDESCENT
CVP Series
Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A • Wet Locations • CUL
Certification Guide
Ambient CLASS I, DIVISION 2 (When
Used With) Supply Wire
Model Temperature
Suitable Temp °C
°C Globe Refractor
AVPH15I, BVPH15I, CVPH15I 40 T2C T2B 90
AVPH26F, BVPH26F, CVPH26F 40 T3C T3C 90
AVPH32F, BVPH32F 40 T3 T3A 90
www.rigalite.com
COMPACT FLUORESCENT • INCANDESCENT
CVP Series
Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A • Wet Locations • CUL
Prismatic Polycarbonate
with Dome Reflector*
4.53
3.96
11.22
4.53
www.rigalite.com
COMPACT FLUORESCENT • INCANDESCENT
CVP Series
Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A • Wet Locations • CUL
Accessories
Globes Guard and Grid
Lamp Thread Catalog Catalog
Type Size Color Diameter Number Description Number
Soda Lime Glass 150W Clear 3-5/16 in. VGL1001 Non-Metallic 59030
Guard
Polycarbonate
Polycarbonate 75W Clear 3-5/16 in. VGL100PPG1 Prismatic Dome CVP100DR
Prismatic Reflector2
Glass
150W Clear 3-5/16 in. VGL100PRISM
Prismatic
To order colored globes, add suffix A (Amber), B (Blue), R (Red) or G (Green) to catalog number.
1
Requires guard catalog number: 59030 (Not available with wall mount fixtures).
2
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
www.rigalite.com
COMPACT FLUORESCENT • INCANDESCENT
AVP Series
Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A • Wet Locations • CUL
Compact Fluor. 26
AVP26-F-12-HR-G-W AVPH26-F-12-HR-G-W 4.6
Compact Fluor. 32
32 AVP32-F-12-HR-G-W AVPH32-F-12-HR-G-W 4.8
Certification Guide
Ambient CLASS I, DIVISION 2 Supply Wire
Model Temperature Suitable
ºC Globe Refractor Temperature ºC
AVPH15I 40 T2C T2B 90
AVPH26F 40 T3C T3C 90
AVPH32F 40 T3 T3A 90
www.rigalite.com
COMPACT FLUORESCENT • INCANDESCENT
AVP Series
Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A • Wet Locations • CUL
Accessories
Globes Guard
Lamp Thread Catalog Catalog
Type Size Color Diameter Number Description Number
Polycarbonate 75W Clear 3-5/16 in. VGL100PPG1
Prismatic
Glass
Prismatic 150W Clear 3-5/16 in. VGL100PRISM
To order colored globes, add suffix A (Amber), B (Blue), R (Red) or G (Green) to catalog number.
1
www.rigalite.com
NOTES
BVP SERIES B
V
Brass Lighting for Marine and Hazardous Environments
P
• Class I, Division 2, Groups A, B, C & D
• Zone 2, Group IIA, IIB, IIC
• UL 844 Hazardous Locations
• UL 1598A Marine Outside Type
• NEMA 3, 4, 4X
BVP SERIES
Brass Luminaire for Marine and Hazardous Environments
Designed to meet the rugged demands of marine, petroleum & industrial applications, the BVP Series is suitable
for Class I, Division 2 hazardous and marine outdoor salt spray areas. It’s rugged construction protects against
corrosion and is suitable for indoor and outdoor applications.
Available in three mounting
styles– pendant, ceiling
and wall mounts.
High-temperature
silicone gasket.
5 GUARD
2 LAMP WATTAGE AND TYPE G = Guard 5
13F = 13 Watt Comp. Fluor. (GX23-2 Base/120V)1
13F = 13 Watt Comp. Fluor. (GX24q-1 Base/277V)1
18F = 18 Watt Comp. Fluor. (G24q-2 Base)2
26F = 26 Watt Comp. Fluor. (GX24q-3 Base)3 6 MOUNTING STYLE
P = Pendant
32F = 32 Watt Comp. Fluor. (GX24q-3 Base)6 W = Wall Mount with Box
15I = Up to 150 Watt (A-21 Max.) Incandescent C = Ceiling
(Medium Base)4
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
www.rigalite.com
COMPACT FLUORESCENT • INCANDESCENT
BVP Series
Cast Marine Brass • Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A • Wet Locations
Catalog Number③➃
Shipping
Lamp Lamp Marine Hazardous & Marine Locations Weight
Mounting Style Type➀➁ Watt UL 1598A UL 844 & UL1598 (Lbs.)
Certification Guide
CLASS I, DIVISION 2
Ambient Supply Wire
(When used with)
Model Temperature Suitable
ºC Globe Refractor Temperature ºC
www.rigalite.com
COMPACT FLUORESCENT • INCANDESCENT
BVP Series
Cast Marine Brass • Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A • Wet Locations
Accessories
Globes Guard
Lamp Thread Catalog
Description Catalog
Type Size Color Diameter Number
Number
Glass 1
To order colored globes, add suffix A
Prismatic 150W Clear 3-5/16 in. VGL100PRISM
(Amber), B (Blue), R (Red) or G (Green) to
catalog number.
2
Requires guard catalog number: 59030 (Not
available with wall mount fixtures).
Colored globes available with BVP only.
www.rigalite.com
RBL SERIES R
B
Marine Inside-Type Berth Light
L
• UL 1598A Marine Inside Type
• Wall Mount
• Compact Fluorescent Lamps
713.943.0340 | azz.com/rigalite
RBL SERIES
Marine Inside Type Berth Light
Neoprene gasket.
Welded copper-free
aluminum powder coated
housing. Heavy duty
acrylic lens.
Two pole
250V rocker switch.
Convenience outlet.
RBL-2-13-A-LCO
1 2 3 4 5
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
www.rigalite.com
FLUORESCENT
RBL Series
UL 1598A Marine Inside Type Berth Light • Welded Aluminum • Prismatic Acrylic Lens
713.943.0340 | azz.com/rigalite
RML SERIES
Marine Inside-Type Mirror Light
Neoprene gasket.
Two pole
250V rocker switch.
Convenience outlet.
RML-2-18-A-LCO
1 2 3 4 5
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
FLUORESCENT
RML Series
UL 1598A Marine Inside Type • Mirror Light • Welded Aluminum • Prismatic Acrylic Lens