The document provides instructions for modeling components in a power flow analysis including loading the model with constant current or voltage, comparing power flow under different conditions, entering maximum voltage values, specifying R and X values for inverters, checking surge impedance loading on lines, understanding that line lengths are only indications not used in calculations, selecting voltage for transformers with on-load tap changers, changing transformer values to the winding base and entering the winding base rating, specifying tap range values for transformers, considering the impact of winding angles, maintaining at least one swing bus connection, and requiring one swing bus for running the load flow.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
154 views1 page
PSSE Workshop
The document provides instructions for modeling components in a power flow analysis including loading the model with constant current or voltage, comparing power flow under different conditions, entering maximum voltage values, specifying R and X values for inverters, checking surge impedance loading on lines, understanding that line lengths are only indications not used in calculations, selecting voltage for transformers with on-load tap changers, changing transformer values to the winding base and entering the winding base rating, specifying tap range values for transformers, considering the impact of winding angles, maintaining at least one swing bus connection, and requiring one swing bus for running the load flow.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1
Model loads as constand current, constand voltage……
Power flow can be compared in different conditions
Maximum voltage value to be neteredd R and X values of inverter for short circuit studies Check surge impedance loading on line Line legth in branch is just an indication None to be used in voltage in OCTC IN OLTC voltage to be slected in branch circuit while modelling transformer Change transformer values to winding base and enter winding base value also as the transformer rated value Rmax and R min are the tap ranges values How winding angle impacts skt Never disconnecvt Swing bus At least 1 swing bus is mandatory for running the load flow