0% found this document useful (0 votes)
388 views4 pages

Perhitungan TPT

The document calculates the stability of a structure against overturning. It provides dimensions and load data for the structure. It then calculates the resisting and overturning moments and checks that the ratio of resisting to overturning moments is greater than 1.5, which would indicate the section is stable against overturning. The calculations show the ratio is 1.29, which is less than 1.5, so the section is determined to be stable against overturning.

Uploaded by

Bobby Bob
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
388 views4 pages

Perhitungan TPT

The document calculates the stability of a structure against overturning. It provides dimensions and load data for the structure. It then calculates the resisting and overturning moments and checks that the ratio of resisting to overturning moments is greater than 1.5, which would indicate the section is stable against overturning. The calculations show the ratio is 1.29, which is less than 1.5, so the section is determined to be stable against overturning.

Uploaded by

Bobby Bob
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

PERHITUNGAN STABILTAS TERHADAP GULING

Data Desain
H1 : 1.5 m H2 : 0.5 m
B1 = 40
b1 : b2 : 0.4 m
q = 7 kN/M2
q : 7 kN/m2 γ : 14 kN/m2 (data berdasarkan
θ : 30
c : 10
H1 =150

W1 = b1 * H1 * γb = 0.4 x 1.50 x
W2 = 1/2 * b1 * H1 * γb = 0.5 x 0.4 x
H2 =30

X1 = 1/2 * b1 + b2 = 0.5 x 0.4 +


B2 = 80 X2 = 1/2 * b2 = 0.5 x 0.4

Mb1 = W1 * X1 = 15 x 0.6
Mb2 = W2 * X2 = 7.5 x 0.2
ΣW =
ΣMb =

Ka = 1 – sin θ / 1 + sin θ = 1 - 30 /
Kp = 1/Ka = 1 / 1/3

Pa1 = Ka * q * H1 = 1/3 x 10 x
Pa2 = 1/2 Ka* γ’ * H1^2 = 1/2 x 4
Pa3 = 1/2 * γ air * H1^2 = 1/2 x 4
Pp = 1/2 * γ * Kp * H2^2 = 1/2 x 14 x

Y1 = 1/2 * H1 = 1/2 x 1.5


Y2 = Y3 = 1/3 * H1 = 1/3 x 1.5
Yp = 1/3 * H2 = 1/3 x 0.3

Mp1 = Pa1 * Y1 = 5 x 3/4


Mp2 = Pa2 * Y2 = 2 x 2/3
Mp3 = Pa3 * Y3 = 2 x 2/3
Mpp =Pp * Yp = 2.7 x 0.1
ΣPa
ΣMp (1-3)
[ΣMb / ΣMp]

[ΣMb / ΣMp] ≥ 1.5 (Safety factor)


[31.50 / 24.45] = 1.29 < 1.5 … ( Penampang aman terhad
ABILTAS TERHADAP GULING

(data berdasarkan kekerasan Tanah di lokasi)

25 x 1 = 15 kN
1.5 x 25 x 1 = 7.5 kN

0.4 = 0.60 m
= 0.2 m

= 9 kN
= 1.5 kN
= 22.5 kN
= 10.5 kN

1 + 30 = 1/3
= 3

1.5 = 5 kN
= 2 kN
= 2 kN
3 x 0.30 ² = 2.7 kN

= 3/4 m
= 2/3 m
= 0 m

= 3.75 kNm
= 1.33 kNm
= 1.33 kNm
= 0.27 kNm
= 9 kN
= 6.42 kNm
= 1.636 Ok

24.45] = 1.29 < 1.5 … ( Penampang aman terhadap guling)