Transmission, Transformer & Protection Lab Lres PDF

TERCO offers comprehensive manuals and training for their products. The document describes their transmission line, transformer, and protection laboratory equipment including line models, transformers, and protection relays. It provides details on core products, recommended peripheral equipment, and other accessories for setting up a full laboratory.

Uploaded by

laxman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
388 views36 pages

Transmission, Transformer & Protection Lab Lres PDF

TERCO offers comprehensive manuals and training for their products. The document describes their transmission line, transformer, and protection laboratory equipment including line models, transformers, and protection relays. It provides details on core products, recommended peripheral equipment, and other accessories for setting up a full laboratory.

Uploaded by

laxman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

Transmission Line,

Transformer & Protection Laboratory


Manuals

TERCO offers comprehensive manuals for each product upon delivery. On request we can also offer them in
digital form.

Guarantee & Terms


All overseas deliveries are dispatched in special, made to order wooden crates, extremely sturdy and
damage resistant.
The guarantee is valid for 24 months from delivery and covers repair or exchange of parts, defective due
to faulty design or workmanship at our factory. Detailed conditions of guarantee are specified in our Terms
of Guarantee.
Spare parts for 2-5 years of normal operation can be offered on request.
Regular after-sales service is performed by the worldwide network of Terco representatives, along with
the advice and support of our engineers.
Commissioning and training is normally offered separately. Special training can be arranged on request
either in Sweden or on site.
Terco is ISO 9001 certified

2
Transmission Line,
Transformer & Protection Laboratory

CONTENT Page
Manuals..............................................................................................................................3
Core Products
Transmission Laboratory.......................................................................................4-9
Line Model MV1420.....................................................................................6
Line Model MV2221.....................................................................................6
Line Model MV2222.....................................................................................7
Line Model MV1424.....................................................................................7
Line Model MV1425.....................................................................................8
Cable Model MV1438..................................................................................9

Transformer Laboratory.....................................................................................10-11
Transformer Single-Phase MV1911...........................................................10
Transformer 3-Phase MV1915.................... ..............................................10

Protection Relays Laboratory............................................................................12-16


Universal Relay Trainer MV1431-1......................................................12-13
Line Multi Protection Trainer MV1450..................................................14-15
Differential Relay Trainer MV1455.......................................................16-17

Recommended Peripheral Equipment


Power Supplies and Generators........................................................................18-19
Mobil Motor / Generator MV1305-405..................................................18-19
Variable Transformer 3-phase MV1103.....................................................19
Power Pack MV1300.................................................................................20
Loads................................................................................................................21-23
Load Resistor MV1100..............................................................................21
Load Reactor MV1101...............................................................................21
Load Capacitor MV1102............................................................................22
Load Capacitor MV1106............................................................................22
Load Reactor MV1107...............................................................................23
Rheostats MV1957, MV1959, MV1963.....................................................23

Instruments and Data Acquisition......................................................................24-29


Digital Multimeter DMC9............................................................................24
Digital Clampmeter AC/DC current MAT220349........................................24
Ammeter MV1922/1923.............................................................................25
Voltmeter MV1926.....................................................................................25
Wattmeter MV1937....................................................................................25
Power Factor Meter MV1929, MV1976.....................................................26
Digital Timer MV1918-1.............................................................................26
Differential Probe MV1971........................................................................26
AC Power Energy Meter MV1939.............................................................27
Analogue Output Module MV1943............................................................28
Data Acquisition and Control Software MV2609..................................28-29

Other Accessories.............................................................................................30-32
Terminal Board MV1429............................................................................30
Load Switch MV1500................................................................................30
Push Button Panel MV1400......................................................................30
Contactor MV1402....................................................................................31
Current Transformer MV1931...................................................................31
Three-phase Transformer MV1915-C.......................................................31
Petersen Coil, Multi Terminal Unit MV2225...............................................32
Laboratory Flexes......................................................................................33
Flex Stand MV1904...................................................................................33

INDEX.......................................................................................................................34

3
TRANSMISSION LABORATORY

Line Models
The following Line Models and Cable Model are designed for realistic conditions, such as overvolt-
age, overcurrent, and a certain magnetic coupling between the wires.
As linear behaviour for excess values is required, the line inductances must be represented by non-
saturable induction coils. To withstand certain overvoltages, overdimensioning of wiring and
capacitors is necessary.

One of the overhead models is representing a high voltage line of 220 kV, and the other a feeder at
medium level 40 kV.
All models are constructed as π-links, the HV model and the cable model as a double π-link.

Flexibility to simulate typical situations, such as compensating a long line at both ends and also in
the middle, must also be available. Combination of the π-links make it possible to create other char-
acteristic data, e.g. capacitors can be connected in ∆ instead of Y.

4
TRANSMISSION LABORATORY

Recommended equipment for


Transmission Laboratory

Cat. Code Description pc page


MV1420 Line Model 3-phase, 230V 1 6

Recommended peripheral equipment for MV1420


MV1103 Variable Transformer, 3-phase 1 19
MV1429 Terminal Board 1 30
MV1100-235 Load Resistor 3-ph, 3.3kW 1 21
MV1107 Load Reactor, 3-ph, 3 kVAr 1 21
MV1102 Load Capacitor, 3-phase, 2.8 kVAr 1 22
MV1500 Load Switch, 3-pole 16A 2 30
MV1915 Transformer, 3-ph 2 kVA 50-60 Hz 2 10
MV1939 AC Power Energy Meter 2 27
MV1830-HF Flex Set, 100 Safety Leads, Safety Plugs 1 33
MV1904 Flex Stand 1 33

Optional:
MV1424 Line Model, 3-ph, 400V, one phi-link (40kV, 40km) 1 7
MV1425 Line Model, 3-ph, 400, double phi-link (220kV, 100km) 1 8
MV1438 Cable Line Model 400V, 3-phase (11kV, 5km) 1 9
MV2221 Line Model 400V 3-phase (230kV, 100km) 1 6
MV2222 Line Model 400V, 3-phase (11kV, 5km) 1 7
MV2225 Petersen Coil, Multi Terminal 1 31
MV1439-235 Power Factor Control Unit 1 32

Additional Equipment: Measuring and Data Acquisition for PC


MV1943 Analog Output Module 1 28
MV2609 Data Acquisition and Control Software 1 29

Alternative instrument
MV1922/23 Ammeter 0-10A, AC/DC 4 25
MV1926 Voltmeter 0-50-250-500V AC/DC 3 25
MV1937 Wattmeter 1-ph, 1-5A; 50-250-500V AC/DC 3 25
MV1929 Power Factor Meter 3-ph, 0-5A, 230V 1 26
MV1976 Power Factor Meter 3-ph, 0-5A, 400V 1 26

5
TRANSMISSION LABORATORY

MV1420 Line Model


Technical Specifications
The model corresponds to a power transmission
line of a length 136 km, voltage 77 kV, amperage
100 A, power rating 13 MW.

Voltage 220-240 V, three-phase


(corresponding to 77 kV)
Amperage 5 A (corresponding to 100 A)
Line resistance 1.5 ohms
Line reactance 3.15 ohms
Line capacitance divided into capacitance to earth
(4 µF) and mutual line capacitance between
phases (8 µF).
The network model can be used to complete a series
of experiments with transmission lines. Those listed Earth impedance 0.8 ohm
and described in detail in the instruction manual Fuses 5A
include:
• Characteristic data of the line Dimensions: 410 x 245 x 160 mm
• Voltage drop on the lines Weight: 10 kg
• Short circuit tests
• Earth fault
The following studies can be made:
1. Measurements of characteristic data,
resisance, reactance and capacitance of a line.
2. As transmission line:
Measurement of voltage drop and losses for
different loads.
3. For two-phase and especially three-phase
short circuit measurements with two three-
phase transformers, one at each end.
4. For single-phase and two-phase earth fault
measurements.

MV2221 Line Model


Line Model 230 kV, 100 km, 400 V 3-phase.
Three-phase model of an overhead power
transmission line 100 km long, voltage 230 kV and
ability 110 MVA.

Model value 400 V : R + 2.20 ohm, L 25 mH,


C + 4uF, Co 2.5 uF.

The network model can be used to complete a se-


ries of experiments with transmission lines. Those
listed and described in detail in the instruction
manual include characteristic data of the line. Volt-
age drop on the lines. Short circuit. Earth fault.

Dimensions: 410 x 245 x 160 mm


Weight: 10 kg

Terco reserves the right to make changes in the design and modifications or improvements of the products at any time
without incurring any obligations

6
TRANSMISSION LABORATORY

MV2222 Line Model


Line Model 11 kV, 5 km, 400 V 3-phase.
Three-phase model of an overhead power
transmission line 5 km long, voltage 11 kV
and ability 5 MVA.
Model value 400 V : R + 2.4 ohm, L 17 mH,
C + 30 nF, Co 20 nF.

The network model can be used to complete a series


of experiments with transmission lines. Those listed
and described in detail in the instruction manual in-
clude characteristic data of the line. Voltage drop on
the lines. Short circuit. Earth fault.

Dimensions: 410 x 245 x 160 mm


Weight: 10 kg

MV1424 Line Model


Technical Specifications
Real line parameters
Nominal length: 40 km
Nominal voltage: 40 kV
Nominal current: 350 A

Positive sequence reactance X+: 15 ohm


Zero sequence reactance X0: 23 ohm
Positive sequence resistance R+: 8.4 ohm

Zero sequence resistance R0: 16.0 ohm


Positive sequence capacitance C+: 400 nF
Zero sequence capitance Co: 265 nF

Line Model specifications


Represented length: 40 km
Nominal voltage: 400 V
Maximum voltage: 600 V

Nominal current: 10 A
Maximum current : 32 A (60 sec)

R1 = 4.7 ohm
R0 = 0.8 ohm
X1 = 2πω x 5.45 mH
X0 = 2.62 ohm
C1 = 1.0 µF
C0 = 0.6 µF

Dimensions: 600 x 600 x 1720 mm


Weight: 190 kg

7
TRANSMISSION LABORATORY

MV1425 Line Model


Real line parameters Technical Specifications
Nominal length is100 km (2 sections, each 50 km). Represented length 100 km with two π-links, each
corresponding to a 50 km section.
Data for one 50 km section
Nominal voltage: 220 kV Data for one π-link
Nominal current: 775 A Nominal voltage: 400 V
Maximum voltage: 600 V
Positive sequence reactance X+ : 18 ohm Nominal current: 10 A
Zero sequense reactance X0: 24 ohm Maximum current (60 sec) 32 A
Positive sequence resistance R+: 1.77 ohm
R1 = 0.5 ohm
R0 = 0.8 ohm
Zero sequence resistance R0: 8.0 ohm
X1 = 2πω x 3.77 mH
Positive sequence capacitance C+: 475 nF
X0 = 1.57 ohm
Zero sequence capacitance C0: 315 nF
C1 = 8.9 µF
C0 = 0.6 µF

Dimensions: 600 x 600 x 1720 mm


Weight: 220 kg

8
TRANSMISSION LABORATORY

MV1438 Cable Model


MV 1438 consists of two cable sections with a
nose section cable area of 150 square mm and
240 square mm respectively.

Real line parameters Line Model


Specifications
PEX Cable 150 square mm Al (one π-link)
Length 5 km corr. 5 km
Nominal voltage 11 kV 400 V
Nominal current 260 A 6A
Transmission ability 5.0 MVA 2.4 kVA
Positive sequence 0.45 µF 0.28 µF
capitance C+

Zero sequence 0.45 µF 0.28 µF


capitance C0
Inductance 1.8 mH 2.84 mH
Resistance 1.1 ohm 1.8 ohm
Zero sequence 2.3 ohm 3.7 ohm
reactance X0
(approx.)

Real line parameters Line Model


Specifications
PEX Cable 240 square mm Al (one π-link)
Length 5 km corr. 5 km
Nominal voltage 11 kV 400 V
Nominal current 340 A 6A
Transmission ability 6.5 MVA 2.4 kVA
Positive sequence 0.55 µF 0.26 µF
capitance C+

Zero sequence 0.55 µF 0.26 µF


capitance C0
Inductance 1.6 mH 3.30 mH
Resistance 0.7 ohm 1.5 ohm
Zero sequence 2.1 ohm 4.3 ohm
reactance X0
(approx.)

Dimensions: 600 x 600 x 1720mm


Weight: 190 kg

Terco reserves the right to make changes in the design and modifications or improvements of the products at any time
without incurring any obligations

9
TRANSFORMER LABORATORY

TRANSFORMER LABORATORY
MV1911 Transformer Single-Phase
Ratings Single-phase 1 kVA, 50-60 Hz
Primary: 230 V ± 5 %
Secondary: 4 x 57.5 V ± 5 %

The secondary winding is divided into four windings


for series or parallel connection.

No load losses Po = 25 W
Impedance voltage ek = 8 %
Resistance voltage ek = 3 %

MV 1911 can be used for determination of operating


characteristics, losses and efficiency of a single-
phase transformer by means of no load, short-circuit
and load tests. The transformer has safety sockets
mounted on the frontpanel with mimic diagrams.

Dimensions: 210 x 150 x 210 mm


Weight: 22 kg

MV1915 Transformer 3-Phase


Ratings Three-phase, 2 kVA, 50-60 Hz,
230/2 x 66.5 V per phase
Primary 0-133-230 V ± 5 % per phase
Secondary Two 66.5 V windings per phase,
each winding having tappings for
0-38.4-44-66.5 V (± 5 %)

The tappings are so arranged that 230 V (star or delta


connection) and 133 V (star, delta or zig-zag connec-
tion) can be obtained for all standard connections.
This transformer has safety sockets mounted on the
frontpanel with mimic diagrams.

No load losses Po = 35 W
Impedance voltage ek = 8%
Resistance voltage ek = 3%

With MV 1915, asymmetrical loading and parallel


connection of three-phase transformers for different
three-phase combinations on the primary and second-
ary side, can be studied.
It can also be used for determination of operating
characteristics, losses and efficiency.

Dimensions: 300 x 190 x 345 mm


Weight: 33 kg

10
TRANSFORMER LABORATORY

Recommended equipment for Transformer Laboratory


Cat. Code Description pc page
MV1911 Transformer Single-Phase 1 10
MV1915 Transformer 3-Phase 1 10

Recommended peripheral equipment for Transformer Laboratory


MV1103 Variable Transformer, 3-phase 1 20
MV1429 Terminal Board 1 30
MV1100-235 Load Resistor 1 21
MV1101 Load Reactor, 3-phase, 2.5 kVAr 1 21
MV1102 Load Capacitor, 3-phase, 2.8 kVAr 1 22
MV1500 Load Switch, 3-pole 16A 1 30
MV1939 Power Energy Meter 1 27
MV1830-HF Flex Set, 100 Safety Leads, Safety Plugs 1 33
MV1904 Flex Stand 1 33
DMC9 Digital Multimeter. Equivalent instruments can be delivered and used. 1 24

Optional:
MV1915-C Transformer 3-phase, sectioned 1 31
MV1931 Current Transformer 1 30
Alternative instruments instead of MV1939 above:
MV1922/1923 Ammeter 4 25
MV1926 Voltmeter 2 25
MV1937 Wattmeter 3 25

Terco reserves the right to make changes in the design and modifications or improvements of the products at any time
without incurring any obligations

11
PROTECTION RELAYS LABORATORY

MV1431-1

Universal Relay Trainer
MV1431-1 is a Universal Relay Trainer intended for
practical training in static relays and relay protection
engineering for applications in power systems.

The Universal Relay Trainer MV 1431-1 is an
integrated training system including different kinds of
static relays, which are common in relay protection
systems around the world.

The static relays used in the experiment unit belong to
the well known ABB COMBIFLEX relay system.

The Universal Relay Trainer MV 1431-1 does not only
include static relays, it also contains a current trans-
former, a voltage transformer and an internal power
supply. These components are all fitted into a sturdy
steel cabinet with a front panel on which all sub units
can be connected using either 4 mm safety sockets or
2 mm signal plug terminals. The choice of 2 mm signal
plug terminals makes the unit compact and suitable for
experiments with the trainer standing on a table.
The focus of the proposed experiments is not only
Mimic diagrams of the relays with large clear symbols the different measuring relays, but the surrounding
are printed on the front panel. Sockets are also pro- auxiliary relays are also described and used to build
vided for test objects. a relay protection.

The rack carries a selection of the static relays used in From the basic operation principles, which can be
modern electric power systems. understood by the experiments, the students obtain
knowledge about how relay protection systems are
Following relays are provided: built and how they will work in different situations.
1. Microprocessor operated double over- and under
voltage relay Experiment Manual
2. Microprocessor operated double over current relay 1. Introduction
3. Microprocessor operated multi-function directional 2. Identifying the Relays
/ reverse power relay 3. Auxiliary Equipment
4. Instantaneous over current relay • Auxiliary relay
5. Two types of auxiliary output relays • Signal/flag relay
6. Multirange time-lag relay • Current measuring relay, classic
7. Flag / signal relay, double unit • Current measuring relay, double
• Voltage measuring relay, double
Built-in are also: • Power measuring relay
• One current transformer • Multifunction time relay
• One voltage transformer • Tripping relay
• Internal power supply
4. Basic Experiments
The laboratory manual for the Universal Relay Trainer • Operating the tripping relay
MV 1431-1 covers from basic operation principles of • Operating the signal relay
each relay up to giving an introduction to the theory • Operating the current relay
and the practical handling of typical situations where • Time delay of the tripping relay
static relays are used to protect certain objects in for • Time delay of the current relay
instance a power plant.
Supply voltage 220-240 V, 50 Hz, 1-ph
The protected object may for example be a MV1431-1 can also be delivered for 60Hz supply
transformer, a generator, a bus bar or a feeder. Dimensions: 510 x 280 x 570 mm
Weight: 30 kg

12
PROTECTION RELAYS LABORATORY

5. Modern Multifunctional Time Relay 8. Operating the Reverse Power Relay


• Time relay at DC-operation • Background and principle diagram
• Time relay at AC-operation • The phase lag circuit
• Time relay together with measuring current • Reverse power caused by low current
relay • Reverse power caused by low voltage
• Reverse power caused by the angle between
6. Double Overvoltage Relay the current and the voltage
• Get familiar with the relay • Reverse power setting
• Define time over/under voltage function • Reverse power in unstable system
• Inverse time over voltage function
• The instantaneous over voltage function 9. Advanced Experiments
• The influence of voltage transformers • Earth-fault protection (95%)
• Earth-fault protection using a current
7. Double Over Current Relay measuring relay
• Get familiar with the relay • Differential protection
• Define time over current function • Reverse power / Loss of synchronization
• Inverse time over current function protection
• The instantaneous over current function
• The influence of current transformer

Recommended peripheral equipment for MV1431-1


Cat. Code Description pc page
Accessories for MV 1431-1, Basic and Medium Level :
MV1103 Variable Transformer, 3-phase 1 20
MV1429 Terminal Board 1 30
MV1500 Load Switch, 3-pole 16A 1 30
MV1918-1 Digital Timer 1 ms-99.99 s 1 26
MV1957 Rheostat 200 W 5 Ohm 6.3 A 1 23
MV1963 Rheostat 500 W 2500 Ohm 0.45 A 2 23
MV1971 Differential Probe 2 26
MV1830-HF Flex Set, 100 Safety Leads, Safety Plugs 1 33
MV1904 Flex Stand 1 33
DM9C*) Digital Multimeter 3 23
MAT220349*) Digital Clamp Meter AC / DC current 1 24

Accessories for MV 1431-1, Extended Level in addition to the Basic and Medium Level :
MV1957 Rheostat 200 W 5 Ohm 6.3 A 1 23
MV1400 Push Button Panel 1 30
MV1402 Contactor 1 31
MV1931 Current Transformer 2 30
MV1911 Transformer, 1-phase 1 kVA 50-60 Hz 1 10
MV1915 Transformer, 3-ph 2 kVA 50-60 Hz 1 10
MV1420 Line Model 3-phase, 230 V 3-phase 1 6
MV1100-235 Load Resistor 3-ph 3.3 kW 1 21
DM9C*) Digital Multimeter 1 24
MAT220349*) Digital Clamp Meter AC / DC current 1 24

Accessory for MV 1431-1, Advanced Level In addition to the levels above :


MV1305-405- Mobile Motor Generator Unit 1 18-19
235

*) Equivalent instruments can be delivered and used

13
PROTECTION RELAYS LABORATORY

MV1450 Line Multi Protection Trainer


This unit is intended for advanced training in modern
line distance protection technology.
The MV1450 Line Multi Protection Trainer is
equipped with the fully IEC61850 compliant ABB
protection REF630 which is one of the most modern
and sophisticated protection units in the product fam-
ily of Intelligent Electronic Devices (IEDs). The use of
a highly advanced IED enables great possibilities to
perform a wide range of laboratory experiments.

The unit is equipped with a large graphical Human


Machine Interface (HMI) with a single line diagram.
Control, monitoring and parameter setting can be
performed either from the HMI or from a PC by
means of the standardized Ethernet interface.
Technical Specification Dimensions: 483 x 356 x 422 mm.
Supply voltage: 230VAC/ (50/60) Hz. Possible to Weight: 37 kg
supply a compatible device with
power (Appendix A at page 10) Protective earth: one 4mm banana connector

Fuse: Two pole 1A/250 VAC, Slow blow, REF630 feeder protection - Features
Cartridge fuse, Glass 5x20 mm • Power bus Circuit breaker control and trip supervi-
sion/disconnection Control, monitoring and protec-
Mains control: Front panel switch tion integrated in one IED.
• Fully IEC 61850 compliant
Power bus: 3ph, 400VAC, 2A • Four independent parameter setting groups
• Large HMI with single line diagram
Power bus circuit breaker switch: • RJ-45 interface for communication with PC
A two state switch (ON/OFF) with
LED indication of CB status. Important protection functions
Internal circuitry prevents operation • Capable of a 5 zone full-scheme high-speed line
of the CB during an distance protection with mho, bullet and quadrilat-
unacknowledged trip. eral characteristics.
Trip reset button: • Three stages of over-current protection (Low, high
Button for quick reset of LEDs and and instantaneous)
acknowledgement of a trip • Directional earth-fault protection
• Over-voltage protection
Current transformers (line currents): • Over-power protection (configurable direction)
Nom. Prim. 2A/ Sec. 1A.
Tolerance class 3: ±3%
Current transformer (torus, residual current):
Nom. Prim. 50A/ Sec. 5A.

Voltage transformers:
Nom. Prim. 230V/Sec. 110V.
Tolerance ±3% (idling voltage 117V)

MV1450-COMP PC with installed and pre-programmed software for MV1450

14
PROTECTION RELAYS LABORATORY

Recommended equipment for MV1450


Cat. Code Description pc page
MV1450 Line Multi Protection Trainer 1 14
MV1450-COMP PC with installed & pre-programmed software for MV1450 1 14

Recommended peripheral equipment for MV1450


MV1103 Variable Transformer, 3-phase 1 19
MV1429 Terminal Board 1 30
MV1100-235 Load Resistor 3-ph, 3.3kW 1 21
MV1101 Load Reactor, 3-phase, 2.5 kVAr 1 21
MV1102 Load Capacitor, 3-phase, 2.8 kVAr 1 22
MV1500 Load Switch, 3-pole 16A 2 30
MV1959 Rheostat 200W, 50 ohm,, 2A 1 23
MV2221 Line Model 230kV, 100km, 400V, 3-phase 2 6
MV2222 Line Model 11kV, 5km, 400V 3-phase 2 7
MV1922/23 Ammeter 0-10A, AC/DC 2 25
MV1926 Voltmeter 0-50-250-500V AC/DC 2 25
MAT220349 Digital Clamp Meter AC / DC current 1 24
MV1830-HF Flex Set, 100 Safety Leads, Safety Plugs 1 33
MV1904 Flex Stand 1 33

Terco reserves the right to make changes in the design and modifications or improvements of the products at any time
without incurring any obligations

15
PROTECTION RELAYS LABORATORY

MV1455 Differential Relay Trainer

The MV1455 unit is intended for advanced


training in modern differential protection
technology. The differential relay trainer is
equipped with the fully IEC61850 compliant
ABB RET615 protective relay which is one
of the most sophisticated protection unit in
the product family of intelligent electronic
devices (IEDs). RET615 is designed for dif-
ferential protection of transformers, genera-
tors, line sections and their combinations.

The use of a highly advanced IED enables


great possibilities to perform a wide range of
laboratory experiments.

The unit is encased in a robust chassis of


sheet metal and is equipped with a large graphical
Human Monitoring Interface (HMI) with a single line
diagram. Control, monitoring and parameter setting Technical Specification
can be configured either from the HMI or from a PC
by means of the standardized Ethernet interface. Power Supply: 230V/50Hz. Possibilty to power
compatible device. (see appendix A)
The protective relay RET615 used in MV1455 ena- Power bus: (3-ph) 400V AC/ 2A with 4 mm banana
bles the student to learn and explore how to protect plugs.
a variety of different power transformer connections
with a differential protection scheme. Size : 357 x 483 x 420 mm
General Features Weight: 37 kg
• Colour coded power inlet- and outlets for easy
recognition of each phase.
• Three power lines; 1 incoming power line and 2 Appendix A – Power supply
outgoing. Each line contain three phases L1, L2,
L3 and Neutral wire.
• Accessible protective ground outlets on the front
as well at the back of the unit.
• 12 current transformers which enables the stu-
dent to study various CT-connections.

• Protection and Control IED Manager PCM600:


Advanced software for configuration and param-
eter setting.
• Mimic diagrams of the circuit along with large If a compatible device is used in conjunction with the
clear symbols printed on the front panel MV1455 it can be powered from the MV1455 unit in-
• Front panel switches that enables the student to stead of occupying an additional wall outlet.
test differential protection on a dual-busbar.

MV1455-COMP PC with installed and pre-programmed software for MV1455

16
PROTECTION RELAYS LABORATORY

Recommended equipment for MV1455


Cat. Code Description pc page
MV1455 Line Multi Protection Trainer 1 16
MV1455-COMP PC with installed & pre-programmed software for MV1450 1 16

Recommended peripheral equipment for MV1450


MV1103 Variable Transformer, 3-phase 1 19
MV1429 Terminal Board 1 30
MV1100-235 Load Resistor 3-ph, 3.3kW 1 21
MV1101 Load Reactor, 3-phase 2.5kVAr 1 21
MV1102 Load Capacitor, 3-phase, 2.8 kVAr 1 22
MV1500 Load Switch, 3-pole 16A 1 30
MV1957 Rhestat 200W, 5 ohm, 6.3A 3 23
MV1959 Rheostat 200W, 50 ohm,, 2A 1 23
MV1400 Push Button Panel 1 28
MV1911 Transformer 1-phase, 1kVA, 50-60 Hz 1 29
MV1915 Transformer 3-phase, 2kVA, 50-60 Hz 1 29
MV1922/23 Ammeter 0-10A, AC/DC 5 30
MV1926 Voltmeter 0-50-250-500V AC/DC 2 30
MAT220349 Digital Clamp Meter AC / DC current 1 30
DMC9 Digital Multimeter 1 31
MV1830-HF Flex Set, 100 Safety Leads, Safety Plugs 1 33
MV1904 Flex Stand 1 33

17
Recommended Peripheral Equipment and Accessories
POWER SUPPLIES AND GENERATORS

MV1305-405 Mobile Motor / Generator Unit


Modes of Operation
A. Control of active power (frequency): AC-
machine and frequency converter drive
(”turbine”) + synchronous machine (gener-
ator) in closed loop connection regarding
frequency.
B. Control of active power (frequency) and
reactive power (voltage): Two closed loops
regarding frequency and voltage.
C. Synchronous compensating: AC-machine
and frequency converter drive (”turbine”)
idling, electrically disconnected or me-
chanically disconnected, synchronous ma-
chine in closed loop connection for voltage
(=reactive power) control.

Technical Specification
A standard laboratory for power transmission normally MV1305-405-235
consists of one or two generators, which are con- Power Supply AC 3-ph 380-415 V
nected to one or more transmission links which finally Frequency 50 Hz
reach transformers, distribution units and loads. This Max current 16A
configuration may look like the very left line in figure 1.
However, a realistic network most likely looks like the Turbine/AC-machine freq.drive:
complete network of figure 1. For example, here can Armature/stator Volt AC 323-528 V
be seen turbine/generators in parallel on the same Frequency 0-63 Hz
busbar, a synchronous machine used as a synchro- Armature/stator current 3.4 A
nous compensator in the middle of a line, a single gen- Input current 5.9 A
erator unit and a heavy group of generators. Rated output current 4.0 A
Energy transfer, load shedding, static and dynamic sta- Rated output capacity 3.2 kVA
bility at disturbances as well as sophisticated protec- Speed 0-1800 rpm
tion schemes can be studied under realistic forms. Not
to forget compensation possibilities. Synchronous generator:
Power- and current- paths in grid networks are compli- Armature volt AC 3-ph 0-140 / 240 V
cated. The TERCO system will give understanding for Power 1.2 kVA
this problem. Cos ϕ 0.8
Field volt 0-230 V DC
The wide range flexibility will be given by the mobile
generator station / synchronous alternator (compensa-
Speed Controll 0-1800 rpm
tor) MV 1305.

Two sets of MV 1305 can operate as described or Active power control SCR-frequency converter,
work in parallel. In this case mechanical and electrical electronic current limit setting,
parameters might be changed by using e.g. flywheel start- and stop ramps.
(MV 1010) and different electrical connections. Feedback systems Manual frequency setting.
Automatic/Constant setting
Field current supply Integrated

Voltage control/
Reactive power control PWM min. ripple-converter,
electronic current limit setting
Feedback systems Manual voltage setting.
Automatic/Constant setting.
Separate voltage feedback

18
Recommended Peripheral Equipment and Accessories
POWER SUPPLIES AND GENERATORS

Instruments
AC-machine freq.drive: Parameters and indications Synchronizing devices:
(Turbine simulator) selected by 4-lines display in Synchronizing instrument
HMI-unit typically like: Double voltmeter
Frequency setpoint (F Double frequency meter
50,00Hz) Synchronizing switch
Stator Electric Frequency (H Automatic or manual synchronizing
51,00 Hz)
Actual motor speed (from Auxiliary:
encoder 1500 rpm) Machines mounted on machine bed with slirails.
Motor current (A 2,20 A) Control panel integrated with machines to one
DC-interlink voltage (V 520 V) mobile unit. Laboratory connections by 4 mm
Speed control potentiometer banana plug of safety type. Possibilities of
(=frequency control) connecting different types of step-up transform-
Control method selector ers
as well as other instruments and protections.
AC-machine M/G: Armature voltage
Voltage selector switch Dimensions: 1550 x 800 x 1200 mm
Armature current Weight: 200 kg (approx.)
Voltage control potentiometer
Control method selector
Field current ammeter

Item Power Supply Synchronous Generator


MV1305-405-235 380-415V 3-ph, 50Hz 220-240V 3-ph, 50Hz
MV1305-405-236 380-415V 3-ph, 60Hz 220-240V 3-ph, 60Hz
MV1305-405-405 380-415V 3-ph, 50Hz 220-240V 3-ph, 50Hz
MV1305-405-406 380-415V 3-ph, 60Hz 220-240V 3-ph, 60Hz

MV1103 Variable Transformer 3-phase


Supplied with a scale showing output voltage.
Thermal overload protection for three output phases are
placed on the front panel. A common shaft rotates all output
voltage sliders in parallel. The unit is mobile on 4 wheels.

Input: 3 x 400 V, 8 A, 50-60 Hz


Output: 3 x 0-450 V, 8 A

Dimensions: 280 x 290 x 560 mm


Weight: 34 kg

19
Recommended Peripheral Equipment and Accessories
POWER SUPPLIES AND GENERATORS

MV1300 Power Pack


This power supply unit is especially adapted for
laboratory experiments on electric machines and
power systems.

It can be used where variable or fixed AC or DC is


required and is particularly suited to the laboratory
experiments with Terco´s torque meters and test
machines. It is designed to slide under the lab table
so that controls and connections are in a comfort-
able working position.

The contactor for variable voltages has a safety limit


switch which eliminates switching on high voltages
by mistake, thus protecting students and equipment
especially when working on electrical machines.
All outputs are fused by MCB´s and have load
switches.

The Power Pack has also Earth Leakages Circuit


Breaker (ELCB).

MV1302 Power Pack


Same as MV 1300-405 but with the following data
Output voltage DC fixed 220 V 3.5 A
DC variable 0-220 V 16 A
General Data AC fixed 400 / 230 V 10 A 3-ph
Supply Voltage AC variable 3 x 0-400 V 8 A 3-ph
MV1300-235 220-240 / 127-140 V 50 / 60 Hz 3-ph. Supply voltage 380-400 / 220-230 V 50 / 60 Hz 3-ph
MV1300-405 380-400 / 220-230 V 50 / 60 Hz 3-ph.
MV1300-415 415 / 240 V 50 / 60 Hz 3-ph.
MV1304 Power Pack
Output voltage DC fixed 220 V 3.5 A As MV1300-415 but with the following data
DC variable 0-220 V 16 A Output voltage DC fixed 220 V 3.5 A
AC fixed 230/133 V 10 A 3-ph DC variable 0-220 V 16 A
AC variable 3 x 0-230 V 10 A 3-ph AC fixed 415 / 240 V 10 A 3-ph
Standard Fixed AC 230 V 10 A AC variable 3 x 0-415 V 10 A 3-ph
Dimensions 660 x 435 x 790 mm Supply voltage 415 / 240 V 50-60 Hz 3-ph
Weight 103 kg

20
Recommended Peripheral Equipment and Accessories
LOADS

MV1100 Load Resistor


MV1100 Load resistor contains three ganged resistors
with continuous spindle regulation. The resistors are
connected to terminals for 3-ph, single-phase or DC-
voltage.
The current in the resistor is limited by tubular wire
fuses in each phase. The unit has handles and
wheels for simple and quick movement and is en-
closed in a perforated metal
cabinet. MV1100 is supplied with safety sockets and a
load switch.
A cooling fan is placed at the bottom of the resistor.
MV1100-235 Cooling fan supply 230 V AC 50 - 60 Hz
MV1100-116 Cooling fan supply 110 V AC 60 Hz
General Data
3-phase 3.3 kW, continuously adjustable.
Star connection 400 / 230 V 0.8-5 A
Star connection 230 / 133 V 0.5-5 A
Delta connection 400 / 230 V 2.4-8.7 A
Delta connection 230 / 133 V 1.3-8.7 A
DC parallel connection 220 V 2.3-15 A
Overload capacity, brief duration, approx. 20 %.
Dimensions): 630 x 250 x 890 mm
Weight: 46 kg

M
od
bu
s
Sy
st MV1101 Load Reactor
em
Mo Enclosed in a strong metal cabinet. The front panel
db has mimic diagram, terminals, fuses and electrical
us
Sy data. The unit can be used on 1- and 3-phase sys-
ste
m tems. 12 step regulation.

General Data
2.5 kVAr, 50-60 Hz
V Connection Hz A
230 star 50 0.2-2.2
230 delta 50 0.6-6.6
400 star 50 0.4-3.8
230 star 60 0.2-1.9
230 delta 60 0.5-5.6
400 star 60 0.3-3.3
Dimensions: 510 x 220 x 320 mm
Weight: 40 kg

21
Recommended Peripheral Equipment and Accessories
LOADS

MV1102 Load Capacitor


Housed in a metal cabinet. Electrical data and sym-
bols on the front panel with terminals and fuses. This
unit can be used on 1- and
3-phase systems. 6 step regulation.

General Data
2.8 kVAr at 50 Hz, 3.3 kVAr at 60 Hz.
V Connection Hz A
230 star 50 0.4-2.4
230 delta 50 1.2-7.2
400 star 50 0.7-4.2
230 III (parallel) 50 2.1-12.6
230 star 60 0.5-2.8
230 delta 60 1.4-8.6
400 star 60 0.8-5.0
230 III (parallel) 60 2.5-15
Dimensions: 185 x 370 x 170 mm
Weight: 7 kg

MV1106 Load Capacitor


The bank is made of metallized paper capacitors. The
capacitors are fitted with discharging resistors. The
capacitance of the bank can be varied in seven steps
by means of rotary switches. It can be used in
single-phase or three-phase circuits.
5.3 kVAr at 50 Hz, 6.3 kVAr at 60 Hz
V Connection Hz A
230 delta 50 1.9-13.4
400 star 50 1.1-7.7
230 III 50 3.3-23.2
230 delta 60 2.3-16.1
400 star 60 1.3-9.2
230 III 60 3.9-27.8
Dimensions: 520 x 225 x 360 mm
Weight 13 kg

22
Recommended Peripheral Equipment and Accessories
LOADS

MV1107 Load Reactor


The reactor is continuously variable within the range
0.5-3.0 kVAr. When the reactor is connected to a sys-
tem with 230 V between lines, the
setting range can be increased to
0.15-3.0 kVAr by using Y-connection.
The required reactive power is set by means of a
crank. For easier setting, the load reactor has a ten-
turn scale with 100 scale divisions for each turn. Each
winding is fitted with a fuse.
3-phase 0.5-3.0 kVAr, 400 V Y, 230 V Y, 50-60 Hz
V Connection Hz A
230 star / delta 50 0.4-7.8
400 star 50 0.7-4.5
230 star / delta 60 0.3-7.6
400 star 60 0.6-3.7
Dimensions: 340 x 170 x 380 mm
Weight: 30 kg

MV1957, MV1959, MV1963


Rheostats
Each rheostat is enclosed in a robust metal case.
The back, bottom and top of the case are perforated
to provide optimum cooling. 2 glass fuses protect the
resistor agains excessive current and incorrect con-
nection.
A scale with 100 scale divisions shows the resistance
setting.
A front panel of yellow painted steel with black
screen painted symbols simplifies series and
potentiometer connection.

Constructional features
The insulation is of high class ceramic material.
The resistance wire used is of highest quality with
very good linearity.
Large flat brush with a sliding contact of copper
graphite with specially balanced mounting guaran-
tees perfect
contact with negligible wear on the resistance.

Cat. no. W Ω I (A) Dimension Weight


HxWxD mm
MV1957 200 5 6.3
140 x 130 x 145 1.5
MV1959 200 50 2.0
MV1963 500 2500 0.45 215 x 195 x 230 3.5

23
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION

DMC9 Digital Multimeter


High-resolution, 3-3/4 digit LCD, 4000-count autoranging
• 7 functions / 23 ranges
• Battery Test function with Go/NoGo LED indicator
• Industry standard test leads, safety rated
• Protective holster included

Voltage
• DC Voltage 400 mV, 4V, 40V, 400V, 600V
• AC Voltage 400 mV, 40V, 400V, 600V

Current
• DC Current 40 mA, 400 mA, 8 A, (10A for 10 min)
• AC Current 40 mA, 400 mA, 8 A, (10A for 10 min)

Resistance
• 400 Ohm, 4 kOhm, 40 kOhm, 400 kOhm, 4 MOhm, 40 MOhm.

Buzzer Sounds
Diode Test
Overload Protection
Included accessories: Protective holster, test leads, battery and
users manual.

Dimensions: 140 x 78 x 50 mm
Weight: 0.22 kg

MAT220349 Digital Clampmeter AC/DC current


MAT229349 is a small and pliable clamp meter for AC and DC cur-
rent up to 200 A.

A clear and easy-to-read 3.5 digit LCD display with max reading of
1999.

The slim jaws have an inner diameter of 30 mm and is easy to fit in


narrow places.

The data-hold function freezes the value, and is useful when work-
ing in the dark or hard to get areas where you cannot see the LCD.

The measuring values are updated 2 times / sec.
MAT220349 is delivered with manual, battery and soft case.

Conforms with IEC safety requirements.

Specifications:
• Current (AC): 0-20 A, 0-150 A, 150-199, 9A
• Current (DC): 0 - 20 A, 0 - 150 A, 150 - 199, 9A
• Low battery indication: ”B” mark on LCD
• Power supply (battery): 2 pcs RS-44 or 2 pcs LR-44

Dimensions: 20 x 44 x 146 mm
Weight: 0.1 kg

24
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION

MV1922/1923 Ammeter
A sturdy amperèmeter with high accuracy and reliability. Extremely safe with
safety sockets and dual insulation. Moulded, water-resistant casing.

Range AC 10mA - 10A (7 steps)


DC 100µA -10A (7 steps)
Accuracy 1,5% (DC), 2% (AC)
Operating frequency 45 - 400Hz
Fuse 1A and 10

Dimensions: 170 x 110 x 60 mm


Weight: 0.4 kg

MV1926 Voltmeter
A sturdy voltmeter with high accuracy and reliability. Extremely safety with
safety sockets and dual insulation. Moulded, water-resistant casing.

Range AC 3V - 1000V (6 steps)


DC 100mV - 1000V (8 steps)
Accuracy 1,5% (DC), 2% (AC)
Operating frequency 20 - 400Hz
Fuse Electronic Protection

Dimensions: 170 x 110 x 60 mm


Weight: 0.4 kg

MV1937 Wattmeter
MV 1937 is an Electronic Wattmeter with active power transducer. The
instrument is panel-type 96 x 96 mm and mounted in durable varnished
sheet metal enclosures having plastic feet. The instrument has a 90°
scale and manages temperatures between -20° and +50°C.It complies
with IEC recommendations.

Technical Data
Voltage ranges: 50 – 250 – 500 V AC / DC
Current ranges: 5 – 10 A, AC / DC
Note : This wattmeter has The current ranges can be changed with a switch when measuring.
a lamp and a buzzer warn-
ing for both overvoltage and Voltage inputs: max 600 V
overcurrent. Current inputs: max 20 A
The current inputs and voltage inputs are insulated from each other : 1.5
kV

Accuracy: 2.5 %
Frequency range: DC – 20 kHz
Input impedance: > 100 kohm (voltage input)
< 3 mohm (current input)
Power supply: 220 – 240 V 50 – 60 Hz
Dimensions: 220 x 117 x 125 mm
Weight: 2 kg

25
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION

MV1929 Power Factor Meter


Three-phase instrument, symmetric load.
Measuring range cap. 0.5 ... 1 ... 0.5 ind.
Current range 0-5 A
Voltage range 220 V ± 20 % 3-phase
Frequency range 40-65 Hz
Accuracy class 1.5
Dimensions: 220 x 117 x 125 mm
Weight: 2 kg

MV1976 Power Factor Meter


Three-phase instrument, symmetric load.
Measuring range cap. 0.5 ... 1 ... 0.5 ind.
Current range 0-5 A
Voltage range 380 V ± 20 % 3-phase
Frequency range 40-65 Hz
Accuracy class 1.5
Dimensions: 220 x 117 x 125 mm
Weight: 2 kg

MV1918-1 Digital Timer


Suitable for measuring the pick-up and drop-out times of
relays and for physical experiments. The timer has two in-
puts that can be wired either to start or stop timing. Timing
is started or stopped by every change at the inputs (make
or break). It is also possible to connect the timer to one of
the inputs only, in which case the closing of a make contact
starts the timer, and the opening of the circuit stops it.
The inputs are protected for over-voltage, AC and DC.
General Data
Two measuring ranges Timer 1 msec - 60 sec
Counter 1 - 65 000 counts
230 V DC max.
Accuracy ± 0.1 % of reading ± 1 digit
Resolution 1 msec
Height of digits 7 mm
Mains supply 220-240 V, 50-60 Hz
Dimensions: 175x200x90 mm
Weight: 1 kg

MV1971 Differential Probe


Voltage up to 1200 V
Frequency range: DC - 1 MHz
Impedance in: approx. 1 Mohm
Impedance out: approx. 500 ohm

Dimensions (HxWxD): 40 x 120 x 65 mm


Weight: 0.3 kg

26
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION

MV1939 AC Power Energy Meter


The Terco MV1939 AC Power Energy Meter is a prac-
tical solution for the study of 1, 2 and 3-Phase AC
power systems up to 500VAC/10A.
A microprocessor-based energy meter provides the
user with an instant overview of the relevant three or
four-wire, 3-Phase network parameters in balanced or
unbalanced networks.
The simplified connection process means your labo-
ratory experiments can be set up and taken down
in just minutes, leaving more time to investigate and
understand the characteristics and ambiguities of
3-Phase power networks.
The Terco MV1939 AC Power Energy Meter enables
the measurement and visualization of a wide range
of parameters in the study of symmetrical as well as
non-symmetrical networks, such as: phase voltages,
phase-to-phase voltages, line currents, mean three-
Technical Specifications
phase current, mean three-phase voltage, mean Power supply 220-240VAC, 50/60Hz
phase-to-phase voltage, three-phase active, reactive Measurement ratings
and apparent powers, mean three-phase power fac- Voltage, V 500VAC max
tors. Current, I 10AAC max
The visualization of parameters is distributed over Reactive Power 5 kVAr
several pages (default preset to display five pages) Active Power 5 kW
where each page simultaneously displays four param- Cos Phi 0-1-0
eters. Communications
The power Energy Meter is furthermore equipped with Serial interface RS485
a standardized industrial data acquisition protocol
(Modbus) and is compatible with the MV2609 Terco Transmission protocol Modbus RTU8N2
DAQ software (MV1943 Computer Interface is neces- Baud Rate 19200kB
sary).
The MV2609 Terco DAQ software utilizes control Environmental Conditions
and a real time graphical presentation programme Ambient temperature 0...55°C
incorporating data manipulation and export to Excel Air humidity 25...95% (no
capabilities. condensation)

Dimension: 255 x 205 x 335 mm


Weight: 10 kg

27
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION

Additional Equipment: Measuring and Data Acquisition for PC

MV1943
Analogue
Output
Module

MV1420
MV2221
MV2222
MV1424
MV1425
Measurement values
MV1438 MV2609 Data Acquistion and
from the line models,
MV1439 Control Software
loads and PFC

The system contains of an


combination of Measuring
units, Control Units, Data
Interface Module and Data
acquisition software, ena-
MV1939 AC Power Energy Meter
bling the user to observe,
control, record and inves-
tigate relevant electrical
data.
An other typical applica-
tion is electrical machines
laboratory.

MV1943 Analog Output Module Technical Specifications


Communication
Interface USB plug and play
The MV1943 Analog Output Operating system
Module integrates the commu- virtual serial port driver 7/Vista/XP
nication interface functionality
of an USB to RS-485 adapter, Field interface RS485
with a 3-channel Modbus con- Maximum devices 32 devices
trolled 0-10V DC source in one Power source USB port
compact unit. Consumption <100 mA
Coupled with the MV2658
PWM Control unit, the MV1943 Voltage output
provides both communication Channels 3
between Terco measuring units and a PC, as well as Channel output 0-10 V
simultaneous motor control. Resolution 12 bit (2.5 mV)
The 3-channel analog output is controlled via PC using Isolation 1500 Vac, Field to Logic
the Terco Data Acquisition Software and enables addi- Control system Terco MV2609 Data Acquisition
tional features such as fully automatic data acquisition. Software
General
Power supply: 220-240VAC, 50/60Hz
Dimensions: 105 x 147 x 167 mm
Weight: 0.3 kg
Continued next page....

28
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION

MV2609 Data Acquisition and Control Software


Acquisition functions
Data is read into the PC via
Modbus to USB link and pre-
sented in real-time in both tabu-
lar and graph form. Data may
be acquired using one of 4 pos-
sible acquirement modes: Sin-
gle, Timed, Semi-Automatic and
Full Automatic*. The saved data
can then be exported in Excel
format for further investigation.

Pre-configured experiment
setups are included but the ex-
periment presentation window
is fully customizable, allowing
the user to select available
hardware, define data columns
and set up graph parameters
such as data sources and titles.
The software is designed to
work with Terco Modbus instru-
ments but may be set up to
communicate with many Mod-
bus devices.

Control functions*
When used together with the
MV1943 Analog Output Module
and the MV2658 PWM DC Con-
trol Module, the Data acquisi-
tion and Control software can
be used to automatically control
a DC machine which can be
implemented, for example, as a
mechanical brake.

29
Recommended Peripheral Equipment and Accessories
OTHER ACCESSORIES

MV1429 Terminal Board


The box has outlets (three phases, zero and earth) for labora-
tory leads with 4 mm diameter plug ins. These outlets are con-
nected to a 5 x 2.5 mm2 cable with a 3-phase CEE plug rated
16A. The connection box is equipped with miniature circuit
breakers for 16 A.

Dimensions: 250 x 240 x 75 mm
Weight: 2.0 kg

MV1500 Load Switch


Three-pole, 16 A, 250 V- DC / 440 V-AC, switch in metal case.
Front panel showing symbols and
technical data.
Marking of terminals input R, S, T
output U, V, W
Dimensions (HxWxD): 95 x 200 x 80 mm
Weight: 1 kg

MV1400 Push Button Panel


MV1400 is a suitable control device
It consists of :
• a signal lamp
• an OFF-button with one break and one make contact
• an ON-button with one break and one make contact.
The buttons are of non-locking type with instantaneous action so that
contact operations are felt on depression of a button.

Dimensions (HxWxD): 75 x 175 x 130 mm


Weight: 1 kg

MV1931 Current Transformer


Primary: 20-15-5 A/Sec. 1 A
Safety sockets
Accuracy class:1.0

Dimensions (HxWxD): 95 x 200 x 80 mm


Weight: 6 kg

30
Recommended Peripheral Equipment and Accessories
OTHER ACCESSORIES

MV1402 Contactor
The contactor is one of the most common components in
automation. It issued, for instance, in remote control and
automatic control systems.

General data
• 3 main contacts with thermal current rating 25 A at
resistive load
• 5 auxiliary contacts (3 make and 2 break) with thermal
current rating 10 A
• Operating coil, 50 Hz or 60 Hz, 230 V

Dimensions (HxWxD) 150 x 245 x 130 mm


Weight: 1.3 kg

MV1915-C Three-phase Transformer


This transformer is cut-away to show the windings,
coils, terminals, insulation, iron core etc.

Rated power: 2 kVA

Dimensions: 300 x 190 x 345 mm


Weight: 27 kg

Note: It is not possible to do any practical experiments


with this transformer.

MV2225 Petersen Coil, Multi Terminal Unit


A Petersen coil is used together with OH-lines in the
range of distribution voltage to medium voltage (MV).

The most common fault is line-to-earth where the current


is limited by the phase voltage from the two healthy leads
divided by the capacitive impedance added by the arc
resistance and the remaining zero sequence impedance.

Since this current is mainly capacitive it could be


balanced by an inductance between the neutral point of
The 3 coils have following values: the transformer and ground. That is to say: when a line-
L = 0.63 H and +/- 30 % terminals (70 kV) to-earth fault occurs it will be extinguished automatically
L = 1.00 H and +/- 30 % terminals (230 kV) by the current in the Petersen coil and the re-closing
L = 100 H and +/- 30 % terminals (11 kV) device will connect power again in a fraction of a second.

MV2225 is to be used together with the Line Models Normally a HV-line has a firm ground. However, in this
MV1420, MV2221 and MV2222. case we may also study a 230 kV model because of
tutorial aspects.
Dimensions: 410 x 245 x 160 mm
Weight : 11 kg Each inductance coil has three steps to optimize the
reactance value for each line of “11 kV”, “70 kV” and
“230 kV”.

31
Recommended Peripheral Equipment and Accessories
OTHER ACCESSORIES

MV1439-235 Power
Factor Control Unit

General Monitoring and Measurement on the controller:


TERCO Power Factor Controller (PFC) is also a module Voltage, Current and Power factor
within our Classical electrical Machine Program. Switching modes: Linear and circular
Indication lamps: Indication lamps for the capacitor
With the PFC you can minimise the currents caused groups which are connected
by reactive losses of power and thereby optimising the
transfer of energy between generation and loading. Physical design
The Power Factor Control Unit is housed in a sturdy ap-
This is becoming more and more important today when paratus box with a clear mimic diagram explaining how
“Saving energy” is vital in a world with focus on pollution to connect the supplying net from the left to the right
and shortage of energy. side where the network in need for power factor com-
pensation is connected.
Field of application Readings, parameters and sub parameters are indi-
Inductive or mixed inductive and resistive networks in cated on the front of the controller. Other settings and
need of compensation, for example when starting and programming than the defaults are simply performed
running induction motors. from the keyboard and displayed on the controller front.

Principles of operation General data:


Depending on the power factor of the loading network a Power supply: 1-ph 220 - 240 V, 50 - 60 Hz
microprocessor will connect groups of capacitors. Dimensions: 510 x 570 x 280 mm
By measuring phase voltages and current the micropro- Weight: 24 kg
cessor will calculate how many capacitive groups that
has to be connected and also in which combinations. Typical Experiments with Terco PFC
• The concept of active power, apparent power and
Electrical details reactive power
Number of 3-ph groups 6 • The concept of power factor and “cos”
Power factor setting 0.7 inductive to 0.7 capacitive • The concept of measuring methods
Nominal voltage 3 x 230 V 50 – 60 Hz • Start current settings (C/k)
Code no. MV 1439-235 • Delay times
• Efficiency and losses
Nominal power 0 – 2 kVAr cap. • Linear and circular switching modes
PF-Controller Automatic or manual • PF-Controller design and schematics
Adjustable delay times, switch- • Programming the controller
ing sequences and strategies. • PF-Controller and resistive/inductive loads
• PF-Controller and induction motor loads
• Control range limits

32
Recommended Peripheral Equipment and Accessories
OTHER ACCESSORIES

Laboratory Flexes with Safety Plugs, Fixed Sleeve


MV1830-HF Flex Set Area 1.5 mm2
Set of 100 leads in 5 different colours, red, yellow, blue, black, yellow/
green, and 4 different lengths, 25, 50, 100 and 200 cm, 5 of each.
25 cm 50 cm 100 cm 200 cm
Red 5 5 5 5
Yellow 5 5 5 5
Blue 5 5 5 5
Black 5 5 5 5
Yellow/green 5 5 5 5

Alternative Flexes: Laboratory Flexes with Safety Plugs, Retractable Shroud


MV1830-H Flex Set Area 1.5 mm2
Set of 100 leads in 5 different colours, red, yellow, blue, black, yellow/
green, and 4 different lengths, 25, 50, 100 and 200 cm, 5 of each.
Length 25 cm 50 cm 100 cm 200 cm
Red 5 5 5 5
Yellow 5 5 5 5
Blue 5 5 5 5
Black 5 5 5 5
Yellow/green 5 5 5 5

Safety lead with 2 covered spring plugs of 4 mm diameter, with retract-


able shroud covering the plugs, and 4 mm diameter axial bushings
moulded with Polypropylen, fixed to 1.5 mm2 copper thread, PVC
isolated, outer diameter 4 mm. Rated current 16 A.

The pin is protected by a plastic The plastic sleeve is pushed in to


sleeve when the flex is not con- the flex when the plug is connected
nected. to the equipment.

MV1904 Flex Stand


For suspension of laboratory flexes. The stand has 12 slots between
parallel tubes with space for 10-15 laboratory flexes in each slot.
Flexes of length 200 cm are suspended in a separate position above
the stand. This rigid stand has a heavy steel plate pedestal.
General Data
Height: 1170 mm
Weight: 9 kg

33
Transmission Line,
Transformer & Protection Laboratory

INDEX Item Description Page


DMC9 Digital Multimeter 24
HXXXX Laboratory Flexes 33
MAT220349 Digital Clampmeter Current 24
MV1100 Load Resistor 21
MV1101 Load Reactor 21
MV1102 Load Capacitor 22
MV1103 Variable Transformer 19
MV1106 Load Capacitor 22
MV1107 Load Reactor 22
MV1300 Power Pack 20
MV1305-405 Mobil Motor/ Generator 18
MV1400 Push Button Panel 30
MV1402 Contactor 31
MV1420 Line Model 6
MV1424 Line Model 7
MV1425 Line Model 8
MV1429 Terminal Board 30
MV1431-1 Universal Relay Trainer 12
MV1438 Cable Model 9
MV1439-235 Power Factor Control Unit 32
MV1450 Line Multi Protection Trainer 14
MV1450-COMP Line Multi Protection Trainer Software 14
MV1455 Differential Relay Trainer 16
MV1455-COMP Differential Relay Trainer Software 16
MV1500 Load Switch 30
MV1904 Flex Stand 33
MV1911 Transformer Single-Phase 10
MV1915 Transformer 3-Phase 10
MV1915-C Three Phase Transformer 30
MV1918-1 Digital Timer 25
MV1922/23 Ammeter 24
MV1926 Voltmeter 24
MV1929 Power Facror Meter 26
MV1931 Current Transformer 30
MV1937 Wattmeter 24
MV1939 AC Power Energy Meter 27
MV1943 Analogue Output Module 28
MV1957 Rheostat 23
MV1959 Rheostat 23
MV1963 Rheostat 23
MV1971 Differential Probe 26
MV1976 Power Facror Meter 26
MV2221 Line Model 6
MV2222 Line Model 7
MV2225 Petersen Coil, Multi Terminal Unit 31
MV2609 Data Acquisition and Control Software 29

34
35
35
TERCO HEADOFFICE

TERCO AB was founded in 1963 with the aim of producing and


supplying practically oriented equipment for technical education.

TERCO develops, manufactures and markets advanced equip-


ment and systems for technical education. TERCO is today
Terco headoffice and factory outside Stockholm, Sweden represented in more than 50 countries world wide.

TRAINING FOR TOMORROW´S WORLD

Electrical Machines &


Power Systems High Voltage
Drives

Mechatronics Process Control Energy

Material Testing Furniture & Power Training


Distribution
2017.05/1000/Östertälje tryckeri

TERCO AB Office/Works: Pyramidbacken 6 Phone: +46 8 506 855 00


P.O. Box 5014 SE-141 75 Kungens Kurva Fax +46 8 506 855 01
SE-141 75 KUNGENS KURVA STOCKHOLM e-mail [email protected]
SWEDEN www.terco.se

36