Transmission Line,
Transformer & Protection Laboratory
CONTENT Page
Manuals..............................................................................................................................3
Core Products
Transmission Laboratory.......................................................................................4-9
Line Model MV1420.....................................................................................6
Line Model MV2221.....................................................................................6
Line Model MV2222.....................................................................................7
Line Model MV1424.....................................................................................7
Line Model MV1425.....................................................................................8
Cable Model MV1438..................................................................................9
Transformer Laboratory.....................................................................................10-11
Transformer Single-Phase MV1911...........................................................10
Transformer 3-Phase MV1915.................... ..............................................10
Other Accessories.............................................................................................30-32
Terminal Board MV1429............................................................................30
Load Switch MV1500................................................................................30
Push Button Panel MV1400......................................................................30
Contactor MV1402....................................................................................31
Current Transformer MV1931...................................................................31
Three-phase Transformer MV1915-C.......................................................31
Petersen Coil, Multi Terminal Unit MV2225...............................................32
Laboratory Flexes......................................................................................33
Flex Stand MV1904...................................................................................33
INDEX.......................................................................................................................34
3
TRANSMISSION LABORATORY
Line Models
The following Line Models and Cable Model are designed for realistic conditions, such as overvolt-
age, overcurrent, and a certain magnetic coupling between the wires.
As linear behaviour for excess values is required, the line inductances must be represented by non-
saturable induction coils. To withstand certain overvoltages, overdimensioning of wiring and
capacitors is necessary.
One of the overhead models is representing a high voltage line of 220 kV, and the other a feeder at
medium level 40 kV.
All models are constructed as π-links, the HV model and the cable model as a double π-link.
Flexibility to simulate typical situations, such as compensating a long line at both ends and also in
the middle, must also be available. Combination of the π-links make it possible to create other char-
acteristic data, e.g. capacitors can be connected in ∆ instead of Y.
4
TRANSMISSION LABORATORY
Optional:
MV1424 Line Model, 3-ph, 400V, one phi-link (40kV, 40km) 1 7
MV1425 Line Model, 3-ph, 400, double phi-link (220kV, 100km) 1 8
MV1438 Cable Line Model 400V, 3-phase (11kV, 5km) 1 9
MV2221 Line Model 400V 3-phase (230kV, 100km) 1 6
MV2222 Line Model 400V, 3-phase (11kV, 5km) 1 7
MV2225 Petersen Coil, Multi Terminal 1 31
MV1439-235 Power Factor Control Unit 1 32
Alternative instrument
MV1922/23 Ammeter 0-10A, AC/DC 4 25
MV1926 Voltmeter 0-50-250-500V AC/DC 3 25
MV1937 Wattmeter 1-ph, 1-5A; 50-250-500V AC/DC 3 25
MV1929 Power Factor Meter 3-ph, 0-5A, 230V 1 26
MV1976 Power Factor Meter 3-ph, 0-5A, 400V 1 26
5
TRANSMISSION LABORATORY
Terco reserves the right to make changes in the design and modifications or improvements of the products at any time
without incurring any obligations
6
TRANSMISSION LABORATORY
Nominal current: 10 A
Maximum current : 32 A (60 sec)
R1 = 4.7 ohm
R0 = 0.8 ohm
X1 = 2πω x 5.45 mH
X0 = 2.62 ohm
C1 = 1.0 µF
C0 = 0.6 µF
7
TRANSMISSION LABORATORY
8
TRANSMISSION LABORATORY
Terco reserves the right to make changes in the design and modifications or improvements of the products at any time
without incurring any obligations
9
TRANSFORMER LABORATORY
TRANSFORMER LABORATORY
MV1911 Transformer Single-Phase
Ratings Single-phase 1 kVA, 50-60 Hz
Primary: 230 V ± 5 %
Secondary: 4 x 57.5 V ± 5 %
No load losses Po = 25 W
Impedance voltage ek = 8 %
Resistance voltage ek = 3 %
No load losses Po = 35 W
Impedance voltage ek = 8%
Resistance voltage ek = 3%
10
TRANSFORMER LABORATORY
Optional:
MV1915-C Transformer 3-phase, sectioned 1 31
MV1931 Current Transformer 1 30
Alternative instruments instead of MV1939 above:
MV1922/1923 Ammeter 4 25
MV1926 Voltmeter 2 25
MV1937 Wattmeter 3 25
Terco reserves the right to make changes in the design and modifications or improvements of the products at any time
without incurring any obligations
11
PROTECTION RELAYS LABORATORY
MV1431-1
Universal Relay Trainer
MV1431-1 is a Universal Relay Trainer intended for
practical training in static relays and relay protection
engineering for applications in power systems.
The Universal Relay Trainer MV 1431-1 is an
integrated training system including different kinds of
static relays, which are common in relay protection
systems around the world.
The static relays used in the experiment unit belong to
the well known ABB COMBIFLEX relay system.
The Universal Relay Trainer MV 1431-1 does not only
include static relays, it also contains a current trans-
former, a voltage transformer and an internal power
supply. These components are all fitted into a sturdy
steel cabinet with a front panel on which all sub units
can be connected using either 4 mm safety sockets or
2 mm signal plug terminals. The choice of 2 mm signal
plug terminals makes the unit compact and suitable for
experiments with the trainer standing on a table.
The focus of the proposed experiments is not only
Mimic diagrams of the relays with large clear symbols the different measuring relays, but the surrounding
are printed on the front panel. Sockets are also pro- auxiliary relays are also described and used to build
vided for test objects. a relay protection.
The rack carries a selection of the static relays used in From the basic operation principles, which can be
modern electric power systems. understood by the experiments, the students obtain
knowledge about how relay protection systems are
Following relays are provided: built and how they will work in different situations.
1. Microprocessor operated double over- and under
voltage relay Experiment Manual
2. Microprocessor operated double over current relay 1. Introduction
3. Microprocessor operated multi-function directional 2. Identifying the Relays
/ reverse power relay 3. Auxiliary Equipment
4. Instantaneous over current relay • Auxiliary relay
5. Two types of auxiliary output relays • Signal/flag relay
6. Multirange time-lag relay • Current measuring relay, classic
7. Flag / signal relay, double unit • Current measuring relay, double
• Voltage measuring relay, double
Built-in are also: • Power measuring relay
• One current transformer • Multifunction time relay
• One voltage transformer • Tripping relay
• Internal power supply
4. Basic Experiments
The laboratory manual for the Universal Relay Trainer • Operating the tripping relay
MV 1431-1 covers from basic operation principles of • Operating the signal relay
each relay up to giving an introduction to the theory • Operating the current relay
and the practical handling of typical situations where • Time delay of the tripping relay
static relays are used to protect certain objects in for • Time delay of the current relay
instance a power plant.
Supply voltage 220-240 V, 50 Hz, 1-ph
The protected object may for example be a MV1431-1 can also be delivered for 60Hz supply
transformer, a generator, a bus bar or a feeder. Dimensions: 510 x 280 x 570 mm
Weight: 30 kg
12
PROTECTION RELAYS LABORATORY
Accessories for MV 1431-1, Extended Level in addition to the Basic and Medium Level :
MV1957 Rheostat 200 W 5 Ohm 6.3 A 1 23
MV1400 Push Button Panel 1 30
MV1402 Contactor 1 31
MV1931 Current Transformer 2 30
MV1911 Transformer, 1-phase 1 kVA 50-60 Hz 1 10
MV1915 Transformer, 3-ph 2 kVA 50-60 Hz 1 10
MV1420 Line Model 3-phase, 230 V 3-phase 1 6
MV1100-235 Load Resistor 3-ph 3.3 kW 1 21
DM9C*) Digital Multimeter 1 24
MAT220349*) Digital Clamp Meter AC / DC current 1 24
13
PROTECTION RELAYS LABORATORY
Fuse: Two pole 1A/250 VAC, Slow blow, REF630 feeder protection - Features
Cartridge fuse, Glass 5x20 mm • Power bus Circuit breaker control and trip supervi-
sion/disconnection Control, monitoring and protec-
Mains control: Front panel switch tion integrated in one IED.
• Fully IEC 61850 compliant
Power bus: 3ph, 400VAC, 2A • Four independent parameter setting groups
• Large HMI with single line diagram
Power bus circuit breaker switch: • RJ-45 interface for communication with PC
A two state switch (ON/OFF) with
LED indication of CB status. Important protection functions
Internal circuitry prevents operation • Capable of a 5 zone full-scheme high-speed line
of the CB during an distance protection with mho, bullet and quadrilat-
unacknowledged trip. eral characteristics.
Trip reset button: • Three stages of over-current protection (Low, high
Button for quick reset of LEDs and and instantaneous)
acknowledgement of a trip • Directional earth-fault protection
• Over-voltage protection
Current transformers (line currents): • Over-power protection (configurable direction)
Nom. Prim. 2A/ Sec. 1A.
Tolerance class 3: ±3%
Current transformer (torus, residual current):
Nom. Prim. 50A/ Sec. 5A.
Voltage transformers:
Nom. Prim. 230V/Sec. 110V.
Tolerance ±3% (idling voltage 117V)
14
PROTECTION RELAYS LABORATORY
Terco reserves the right to make changes in the design and modifications or improvements of the products at any time
without incurring any obligations
15
PROTECTION RELAYS LABORATORY
16
PROTECTION RELAYS LABORATORY
17
Recommended Peripheral Equipment and Accessories
POWER SUPPLIES AND GENERATORS
Technical Specification
A standard laboratory for power transmission normally MV1305-405-235
consists of one or two generators, which are con- Power Supply AC 3-ph 380-415 V
nected to one or more transmission links which finally Frequency 50 Hz
reach transformers, distribution units and loads. This Max current 16A
configuration may look like the very left line in figure 1.
However, a realistic network most likely looks like the Turbine/AC-machine freq.drive:
complete network of figure 1. For example, here can Armature/stator Volt AC 323-528 V
be seen turbine/generators in parallel on the same Frequency 0-63 Hz
busbar, a synchronous machine used as a synchro- Armature/stator current 3.4 A
nous compensator in the middle of a line, a single gen- Input current 5.9 A
erator unit and a heavy group of generators. Rated output current 4.0 A
Energy transfer, load shedding, static and dynamic sta- Rated output capacity 3.2 kVA
bility at disturbances as well as sophisticated protec- Speed 0-1800 rpm
tion schemes can be studied under realistic forms. Not
to forget compensation possibilities. Synchronous generator:
Power- and current- paths in grid networks are compli- Armature volt AC 3-ph 0-140 / 240 V
cated. The TERCO system will give understanding for Power 1.2 kVA
this problem. Cos ϕ 0.8
Field volt 0-230 V DC
The wide range flexibility will be given by the mobile
generator station / synchronous alternator (compensa-
Speed Controll 0-1800 rpm
tor) MV 1305.
Two sets of MV 1305 can operate as described or Active power control SCR-frequency converter,
work in parallel. In this case mechanical and electrical electronic current limit setting,
parameters might be changed by using e.g. flywheel start- and stop ramps.
(MV 1010) and different electrical connections. Feedback systems Manual frequency setting.
Automatic/Constant setting
Field current supply Integrated
Voltage control/
Reactive power control PWM min. ripple-converter,
electronic current limit setting
Feedback systems Manual voltage setting.
Automatic/Constant setting.
Separate voltage feedback
18
Recommended Peripheral Equipment and Accessories
POWER SUPPLIES AND GENERATORS
Instruments
AC-machine freq.drive: Parameters and indications Synchronizing devices:
(Turbine simulator) selected by 4-lines display in Synchronizing instrument
HMI-unit typically like: Double voltmeter
Frequency setpoint (F Double frequency meter
50,00Hz) Synchronizing switch
Stator Electric Frequency (H Automatic or manual synchronizing
51,00 Hz)
Actual motor speed (from Auxiliary:
encoder 1500 rpm) Machines mounted on machine bed with slirails.
Motor current (A 2,20 A) Control panel integrated with machines to one
DC-interlink voltage (V 520 V) mobile unit. Laboratory connections by 4 mm
Speed control potentiometer banana plug of safety type. Possibilities of
(=frequency control) connecting different types of step-up transform-
Control method selector ers
as well as other instruments and protections.
AC-machine M/G: Armature voltage
Voltage selector switch Dimensions: 1550 x 800 x 1200 mm
Armature current Weight: 200 kg (approx.)
Voltage control potentiometer
Control method selector
Field current ammeter
19
Recommended Peripheral Equipment and Accessories
POWER SUPPLIES AND GENERATORS
20
Recommended Peripheral Equipment and Accessories
LOADS
M
od
bu
s
Sy
st MV1101 Load Reactor
em
Mo Enclosed in a strong metal cabinet. The front panel
db has mimic diagram, terminals, fuses and electrical
us
Sy data. The unit can be used on 1- and 3-phase sys-
ste
m tems. 12 step regulation.
General Data
2.5 kVAr, 50-60 Hz
V Connection Hz A
230 star 50 0.2-2.2
230 delta 50 0.6-6.6
400 star 50 0.4-3.8
230 star 60 0.2-1.9
230 delta 60 0.5-5.6
400 star 60 0.3-3.3
Dimensions: 510 x 220 x 320 mm
Weight: 40 kg
21
Recommended Peripheral Equipment and Accessories
LOADS
General Data
2.8 kVAr at 50 Hz, 3.3 kVAr at 60 Hz.
V Connection Hz A
230 star 50 0.4-2.4
230 delta 50 1.2-7.2
400 star 50 0.7-4.2
230 III (parallel) 50 2.1-12.6
230 star 60 0.5-2.8
230 delta 60 1.4-8.6
400 star 60 0.8-5.0
230 III (parallel) 60 2.5-15
Dimensions: 185 x 370 x 170 mm
Weight: 7 kg
22
Recommended Peripheral Equipment and Accessories
LOADS
Constructional features
The insulation is of high class ceramic material.
The resistance wire used is of highest quality with
very good linearity.
Large flat brush with a sliding contact of copper
graphite with specially balanced mounting guaran-
tees perfect
contact with negligible wear on the resistance.
23
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION
Dimensions: 20 x 44 x 146 mm
Weight: 0.1 kg
24
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION
MV1922/1923 Ammeter
A sturdy amperèmeter with high accuracy and reliability. Extremely safe with
safety sockets and dual insulation. Moulded, water-resistant casing.
MV1926 Voltmeter
A sturdy voltmeter with high accuracy and reliability. Extremely safety with
safety sockets and dual insulation. Moulded, water-resistant casing.
MV1937 Wattmeter
MV 1937 is an Electronic Wattmeter with active power transducer. The
instrument is panel-type 96 x 96 mm and mounted in durable varnished
sheet metal enclosures having plastic feet. The instrument has a 90°
scale and manages temperatures between -20° and +50°C.It complies
with IEC recommendations.
Technical Data
Voltage ranges: 50 – 250 – 500 V AC / DC
Current ranges: 5 – 10 A, AC / DC
Note : This wattmeter has The current ranges can be changed with a switch when measuring.
a lamp and a buzzer warn-
ing for both overvoltage and Voltage inputs: max 600 V
overcurrent. Current inputs: max 20 A
The current inputs and voltage inputs are insulated from each other : 1.5
kV
Accuracy: 2.5 %
Frequency range: DC – 20 kHz
Input impedance: > 100 kohm (voltage input)
< 3 mohm (current input)
Power supply: 220 – 240 V 50 – 60 Hz
Dimensions: 220 x 117 x 125 mm
Weight: 2 kg
25
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION
26
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION
27
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION
MV1943
Analogue
Output
Module
MV1420
MV2221
MV2222
MV1424
MV1425
Measurement values
MV1438 MV2609 Data Acquistion and
from the line models,
MV1439 Control Software
loads and PFC
28
Recommended Peripheral Equipment and Accessories
INSTRUMENTS AND DATA ACQUISITION
Pre-configured experiment
setups are included but the ex-
periment presentation window
is fully customizable, allowing
the user to select available
hardware, define data columns
and set up graph parameters
such as data sources and titles.
The software is designed to
work with Terco Modbus instru-
ments but may be set up to
communicate with many Mod-
bus devices.
Control functions*
When used together with the
MV1943 Analog Output Module
and the MV2658 PWM DC Con-
trol Module, the Data acquisi-
tion and Control software can
be used to automatically control
a DC machine which can be
implemented, for example, as a
mechanical brake.
29
Recommended Peripheral Equipment and Accessories
OTHER ACCESSORIES
30
Recommended Peripheral Equipment and Accessories
OTHER ACCESSORIES
MV1402 Contactor
The contactor is one of the most common components in
automation. It issued, for instance, in remote control and
automatic control systems.
General data
• 3 main contacts with thermal current rating 25 A at
resistive load
• 5 auxiliary contacts (3 make and 2 break) with thermal
current rating 10 A
• Operating coil, 50 Hz or 60 Hz, 230 V
MV2225 is to be used together with the Line Models Normally a HV-line has a firm ground. However, in this
MV1420, MV2221 and MV2222. case we may also study a 230 kV model because of
tutorial aspects.
Dimensions: 410 x 245 x 160 mm
Weight : 11 kg Each inductance coil has three steps to optimize the
reactance value for each line of “11 kV”, “70 kV” and
“230 kV”.
31
Recommended Peripheral Equipment and Accessories
OTHER ACCESSORIES
MV1439-235 Power
Factor Control Unit
32
Recommended Peripheral Equipment and Accessories
OTHER ACCESSORIES
33
Transmission Line,
Transformer & Protection Laboratory
34
35
35