0% found this document useful (0 votes)
559 views71 pages

Ametek Gemco Linear Transducers PDF

Uploaded by

Tamilselvan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
559 views71 pages

Ametek Gemco Linear Transducers PDF

Uploaded by

Tamilselvan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 71

Ordering Guide For

Linear Displacement Transducers

ABSOLUTE PROCESS CONTROL


KNOW WHERE YOU ARE... REGARDLESS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com


AUTOMATION & PROCESS
TECHNOLOGIES

Gemco Magnetostrictive Technology Made Easy

In a Gemco position sensor, a current pulse is Non-Linearity


sent down a magnetostrictive wire in a specially The degree that the indicated position of the
designed waveguide (Figure A). The interaction of magnet at points along the stroke varies from the
this current pulse with the magnetic field created by actual physical position. Non-linearity of an LDT is
the movable magnet assembly produces a torsional expressed in absolute error or as a percentage of
strain pulse on the wire, which travels at sonic the active stroke length.
speed along the wire (Figure B). The strain pulse
traveling up the wire is sensed by a small induction Resolution
pickup coil in the head assembly of the LDT. The Resolution is the smallest incremental change in
position of the movable magnet is determined with position along the stroke length of the sensor that
high precision by measuring the time between the can be detected and indicated in an output. When
launching of the current pulse and the arrival of the using LDTs with analog output (i.e., voltage or
torsional strain pulse. The result is highly accurate current outputs), resolution is limited by the amount
non-contact position sensing with absolutely no of power supply-induced output ripple and the
wear on the sensing element. sensitivity and/or design capabilities of the receiver
electronics. Digital system resolution is defined by a
Hysteresis specific value.
The difference in indicated position when the same
point is reached from two different directions. Recirculation
A method used to improve the resolution of a
Repeatability system using digital LDTs. The on time of the
The deviation in indicated position when a point pulse width output is multiplied by a specific factor.
along a stroke length is approached repeatedly from This multiplication provides more counting time
the same direction. for the counter in the customer’s electronics, thus
improving the resolution.
Magnetostriction
A magnetic field produces a small change in the
physical dimensions of ferromagnetic materials on
the order of several parts per million in carbon steel
and, conversely, a physical deformation or strain (or
stress which causes strain) produces a change of
magnetization in the material.

3 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Principles Of Operation

Series Voltage Current Digital Quadrature Protocol

950IS
V I
950IS

950MD
Housing Only.
950MD This housing accepts all rod style LDTs.

V I D Q

952
952

V I Clock (+)
D Data (+)

953
953
SSI

V I D Q

955
955

Housing Only.

956
956 This housing accepts all Series 955 BRIK style LDTs.

7230
7230 Modbus

I 7330
7330
Misc.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 3
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Applications

Competitive Drop In
Food and Beverage
Harsh Environment

Multiple Magnet
Programmable
Replacements

Capabilities
“Mill-Duty”

Hazardous
Locations

Field
Series
950IS

950MD

952
  952A
Differential
952
Stainless Steel    952A
Differential
952 w/ T or M
Connectors    Consult
Factory
952RS
  Consult
Factory
953
  
953 w/ M or B
Connectors   
953RS
 Consult
Factory 
955e
 
955LC

955D
N/A

955S/955A
  955A
Differential
955S
w/ FM Approval  
956
 Sensor
Dependant

7230

7330
  
7330S
  

4 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Principles Of Operation
Analog Version
The analog units are an industry standard and The output’s count direction, zero and span are
are available with voltage or current outputs. The all programmable. The 952, 953 and 955A and S
output format, voltage or current, is hardware units are programmable without any accessories or
specified. The 952, 953 and 955 model LDTs adaptors.
have programmable voltage and current outputs.

Voltage Voltage Current Current


10 10 20 20

Distance Distance Distance Distance


Full Stroke Full Stroke 4 Full Stroke 4 Full Stroke

Control Pulse
The control pulse signal interface is a differential should be 1.0 microsecond in duration. The time
RS422 output. The maximum cable length for the between the leading edge of the start pulse to the
differential digital LDT is 1,500 feet. To initiate a start leading edge of the stop pulse is the proportional
pulse, an external device is used. This start pulse distance from the magnet to the hex head.

1 MICROSECOND (RECOMMENDED)
0.2 MICROSECONDS (MINIMUM)

+ INPUT (START PULSE)

TIME BETWEEN PULSES IS PROPORTIONAL TO


DISTANCE BETWEEN MAGNET AND HEX HEAD

+ OUTPUT (STOP PULSE)

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 5
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Output Types

Variable Pulse (PWM) RS422 Start/Stop with


The variable pulse signal interface is a pulse Interrogation Start Sequence
width modulated signal (RS422). The maximum The start/stop uses a 1 microsecond (minimum)
cable length for the differential LDT is 1,500 feet. external interrogation input to start a cycle. Based
The LDT can also be configured for external or on the interogation input, a pair of one microsecond
internal interrogation. External interrogating is return pulses are received and the time differential
when an external device connected to the LDT between the signals is proportional to the distance
generates a start pulse. This start pulse should be from the sensor head (hex) and magnet.
a minimum of 1.0 microsecond in duration. Within
50 nanoseconds after the leading edge of the start
pulse has been received, the LDT will generate
an output pulse. The duration of the output pulse 1 MICROSECOND (RECOMMENDED)

is proportional to the distance from the magnet 0.2 MICROSECONDS (MINIMUM)

to the hex head. The order of these two pulses


is illustrated below. The LDT can also generate INPUT (INTERROGATION PULSE)
TIME BETWEEN PULSES IS PROPORTIONAL TO

internal interrogations. This LDT will continually DISTANCE BETWEEN MAGNET AND HEX HEAD

output pulse width modulated signals. As with an


LDT using an external interrogation, the duration of
this output pulse is proportional to the distance from OUTPUT (START PULSE) OUTPUT (STOP PULSE)
the magnet to the hex head. WITHIN 2.0 MICROSECONDS AFTER INTERROGATION
PULSE BEGINS, START PULSE BEGINS

EXTERNAL INTERROGATION

1 MICROSECOND (RECOMMENDED)
0.2 MICROSECONDS (MINIMUM) TTL Level Start/Stop Version
The TTL Level start/stop pulse system looks at a
INPUT (INTERROGATION)
one microsecond TTL pulse (minimum) start pulse
WIDTH OF PULSE IS PROPORTIONAL TO
from an external source. The unit will then generate
DISTANCE BETWEEN MAGNET AND HEX HEAD a TTL level stop pulse. The time span between the
start/stop pulses is proportional to the distance from
OUTPUT PULSE
the sensor head (hex) to the magnet.
WITHIN 50 NANOSECONDS AFTER INTERROGATION
TO DISTANCE BETWEEN MAGNET AND HEX HEAD

1 MICROSECOND (RECOMMENDED)
0.2 MICROSECONDS (MINIMUM)

INTERNAL INTERROGATION

WIDTH OF PULSE IS PROPORTIONAL


TO DISTANCE BETWEEN MAGNET AND HEX HEAD INPUT (INTERROGATION PULSE)
TIME BETWEEN PULSES IS PROPORTIONAL TO
DISTANCE BETWEEN MAGNET AND HEX HEAD

OUTPUT PULSE
LOW OUTPUT VARIES DEPENDING ON LENGTH
PROGRAMMED VIA DIP SW2 SWITCHES 1-6 OUTPUT (START PULSE) OUTPUT (STOP PULSE)
WITHIN 2.0 MICROSECONDS AFTER INTERROGATION
PULSE BEGINS, START PULSE BEGINS

6 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Output Types
Quadrature Output SSI (Synchronous Serial Interface)
A new method of interfacing magnetostrictive Displacement value is encoded into a 24, 25 or
transducers offers an interface as common as 26 Bit format and transmitted at high speeds.
analog with the speed and accuracy of a digital Synchronization in a closed loop system is made
pulsed type signaling. The Gemco quadrature easy. A clock pulse train from a controller is used
LDTs provide quadrature output directly from the to gate out sensor data: one bit of position data is
transducer to the controller. The output from the transmitted to the controller per one clock pulse
transducer can be wired directly to any incremental received by the sensor. The absolute position data
encoder input or counter card, without the need for is continually updated by the sensor and converted
a special converter module or PLC interface card by the shift register into serial information. The
designed specifically for use with pulsed output sensors fulfill all requirements to the SSI standard
magnetostrictive transducers. The quadrature output for absolute encoders.
has the “A”, “B” and “Z” outputs. These outputs
are “differential” (also known as balanced), which SSI Logic Diagram
means that the connection for each output consists
of two signal wires. These are typically described

SSI Shift Register and Controller


Output Data Format Conversion
as the “plus” and “minus” signals. For example, the SSI Clock (+)

“A” channel consists of “A+” and “A-”. The same Position Measurement
SSI Clock (-)

applies to the “B” and “Z” channels. For these


(differential) outputs, the signal is measured with the SSI Data (+)

reference to the other signal (i.e. the difference or


SSI Data (-)
differential). For example, if the “A+” single voltage
is greater than the “A-” signal, channel “A” is a logic +7 to 30 V
Input
“0”. Again, this applies to the “B” and “Z” channels Power
Supply
as well. Differential type signals are much less 0V

prone to interference caused by electrical noise


or ground loops more often found in single ended SSI Sensor Input
signal connections. Line drivers are also available +5V

for driving single ended inputs that are not TTL RS-422 4.7KΩ 10Ω

compatible. 470Ω
SSI Clock (+)
10Ω
SSI Clock (-)
4.7KΩ 12V 12V

+A RS-422 10Ω
-A SSI Data (+)
10Ω
SSI Data (-)
+B
-B 12V 12V

+Z
-Z Ferrite
Filter

Input Power Supply (+)


Power 33V
Supply
Common

SSI Timing Diagram

Clock Interval Min. 16 µs


Clock (+)

Data (+)
MSB LSB

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 7
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
952QD BlueOx 955S Smart
952 BlueOx 953 VMAX 955LC BRIK 955 eBRIK
Quadrature BRIK
Supply Voltage 15-26 VDC 15-26 VDC 7-30 VDC 24 VDC 24 VDC 10-30 VDC
Analog Outputs
4-20mA Yes No Yes Yes Yes Yes
0-10 VDC Yes No Yes Yes Yes Yes
Digital Outputs
Stop/Start Yes No Yes No No No
Control Pulse Yes No Yes No No No
Pulse Width Modulated Yes No Yes No No No
Velocity No No No No No No
DeviceNet Consult Factory Consult Factory Consult Factory Consult Factory Consult Factory Consult Factory
SSI (Synchronous Serial No No Yes No No
Interface) No
Modbus No No No No No No
Performance
Position Accuracy 0.05% 0.05% 0.01% 0.1% 0.03% 0.1%
(of full stroke)
Repeatability 0.006% 0.001% 0.00006” 0.01% 0.001% 0.01%
(of full stroke)
Resolution Internal 0.001” Analog - 0.00006” Internal 16-Bit Internal
Resolution 0.001” Digital - Controller Resolution 0.014” Resolution 0.014”
Dependant
SSI - Up to 1 Micron
Mechanical Considerations
Lengths - 0.1” Increments 2-168” 2-168” 1-300” 6-180” 1-72” 4-180”
Null Zone 2” 2” 2” STD (1.5 optional) 3” STD (1.5 optional) 2.75” 3”
Dead Band 2.5” 2.5” 2.5” STD 1.5” STD (2.25 2.75” 1.5”
(2.25 optional) optional)
In Cylinder Mounting Yes Yes Yes On Cylinder On Cylinder On Cylinder
Mounting Mounting Mounting
Enclosure Rating (IP) IP67 IP67 IP68 IP67 IP67 IP67,
IP68 Optional
Optional Mill Duty Housing Yes Yes Yes No No No
Options & Features
Hand-Held Programmer Yes No Yes No Yes Yes
Ability to Program via PC No No Consult Factory No No No
Competitive Style Yes No Yes No No No
Connector
High Shock & Vibration Excellent Excellent Excellent Good Good Good
Multiple Magnets Yes No Yes No No No
Universal Mounting Kit Yes Yes Yes Yes Yes Yes
Metric Yes Yes Yes N/A Yes Yes
Threads & Dimensions
All Stainless Steel Yes Yes Yes No No No
(Head & Potted Connector)
High Temp Cables Yes Yes Yes Yes No No
Applications
Measurement Yes Yes Yes No Yes No
Heavy Industry, Lumber, Yes Yes Yes Consult Factory Consult Factory Consult Factory
Metal Stamping, etc.
Positioning, Replacing Yes Yes Yes Yes Yes Yes
Prox or Limit Switches
Cost Mid-Range Mid-Range Mid-Range Low Low Low

8 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955DQ BRIK 956 BLOK


955A BRIK 955D BRIK 7230 Digital Stik 7330 Pro-Stik II
Quadrature Housing Option
13.5-30 VDC 13.5-30 VDC 13.5-30 VDC * 10-30 VDC 13.5-30 VDC

Yes No No Yes Optional Yes


Yes No No Yes No No

No Yes No Yes No No
No Yes No Yes No No
No Yes No Yes No No
No Controller No Controller No No
Dependent Dependent
Consult Factory Consult Factory Consult Factory Consult Factory No No
No No No No No No
No No No No Yes No

0.05% 0.05% 0.05% * 0.01% 0.1%


0.006% 0.006% 0.006% * 0.0001” 0.1%

Internal Controller 0.001” * 0.0001” Internal


Resolution 0.001” Dependent Resolution 0.014”

5-180” 5-180” 5-180” 4-36” 14-288” 8-288”


3” 3” 3” * 9.25” 8”
2” 2” 2” * 2.75” 2”
On Cylinder Mounting On Cylinder Mounting On Cylinder Mounting * No No
IP67, IP67, IP67, * IP66 IP68,3A Optional
IP68 Optional IP68 Optional IP68 Optional
No No No No No No

Yes Consult Factory Consult Factory * No No


Consult Factory Consult Factory Consult Factory * Yes No
No No No * No No

Good Good Good * Good Good


No Yes No * Yes No
Yes Yes Yes * No No
Yes Yes Yes * No N/A

No No No * No, Probe Only Yes

No No No * Consult Factory Consult Factory

Yes Yes Yes Yes Yes Yes


Consult Factory Consult Factory Consult Factory Yes No No

Yes Yes Yes Yes Yes Yes

Mid-Range Mid-Range Low Mid-Range Mid-Range Mid-Range

*The 956 BLOK is a housing option for the 955 BRIK. Refer to the 955 BRIK with the chosen output for complete sensor specifications.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 9
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

The Gemco 950IS Intrinsically Safe LDT


The 950IS can be used in hazardous environments
when connected to an approved safety barrier. The
LDT is UL & CSA listed for Class I, Group C & D,
Class II, Groups E, F, & G and Class III hazardous
locations, when properly installed.

The term ‘Intrinsically Safe’ is used to describe


950IS

electronic equipment that has the ability to be


mounted directly in explosive atmospheres without
chance of an explosion. The term ‘Intrinsically
Safe’ pertains to a device’s inability to produce an
electrical spark of enough significance to cause
ignition.

How does an Intrinsically Safe LDT work? A Gemco


Transmitter (950-1446) is located in a “safe” or
“non-explosive” area which accepts the system’s
supply voltage (115 VAC, 230 VAC, or 24 VDC)
and generates the LDTs positional output signal in
voltage or current. The transmitter also generates
and accepts the LDT signals. These signals are
driven through an approved intrinsically safe barrier Specifications
assuring the safety of the system. Custom 950 Mill 24 VDC @ 85mA max.
Input Voltage/
Duty enclosures are available for this LDT. Current Draw
115 VAC 50/60 Hz @ 6 VA
230 VAC 50/60 Hz @ 6 VA
0 to 10 VDC or 10 to 0 VDC
Output 4 to 20mA or 20 to 4mA
Consult Factory if installing Linearity .01”
950IS into 950MD Housing Repeatability +/- 0.01% of Full Stroke

Operating Temperature
-10° to 180° F
The 950IS is designed to work with Gemco style Head Electronics (-23° to 82° C)
magnets. If installing in a hydraulic cylinder a Gemco -40° to 185° F
Guide Tube
style magnet must be used. (-40° to 85° C)
3000 psi Operational,
Operating Pressure 8000 psi Spike
Span Length 1” to 300”

Null Zone 2”

Dead Band 5”

Connectors 2 Pin 12mm

Enclosure IP65
Specifications are subject to change without notice.

10 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

The Gemco 950IS Intrinsically Safe LDT

9501445 0120 NOTE 1: A complete system consists of an LDT,


a Gemco Magnet, a Tranceiver and IS Barrier.
950IS IS Barrier and Panel Mount Bracket are ordered
Intrinsically
Safe LDT separately. IS Barrier P/N 04517039. Panel Mount
Bracket for Barrier P/N 04517214.

950IS
Stroke Length
NOTE 2: This 950IS model transducer must use a
Insert stroke length to 0.1 inch. Enter as a four-
place number. Example: A 12.0” stroke enters
Gemco style magnet. See pages 60-62 for magnet
as 0120. To convert metric strokes, multiply options.
millimeter value by 0.03937 for inch value.
NOTE 3: All Intrinsically Safe LDTs include a 6 ft.
cable with a straight connector, P/N 04521210.
Consult the factory for longer lengths and right
angle versions.
9501446 24 0120
NOTE 4: Specify magnet style desired as separate
Analog line item. Model number SD0400800 is standard.
Transceiver for
950IS LDT
NOTE 5: The 950IS is NOT compatible with
competitive style magnets. The 950IS MUST use
Input Voltage
Gemco style magnets.
24 24 VDC
115 115 VAC
230 230 VAC

Stroke Length
Insert stroke length to 0.1 inch. Enter as a four-
place number. Example: A 12.0” stroke enters
as 0120. To convert metric strokes, multiply
millimeter value by 0.03937 for inch value.

9501445 Configuration
Outputs

I.S. Barrier

Approved
Conduit
Seal

Input
Voltage

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 11
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
950IS Intrinsically Safe AUTOMATION & PROCESS
TECHNOLOGIES

Dimensions & Wiring Diagram


The Gemco 950IS Intrinsically Safe LDT
Dimensions & Wiring Diagram
120 VOLT 6O HZ APPLICATION 24O VOLT 6O HZ APPLICATION (Optional)

TO ASSOCIATED EQUIPMENT
4-2O MA. ISOLATED OUTPUT
(1,OOO OHM LOOP CIRCUIT MAXIMUM)
NOT USED MIN.R. MINIMUM RANGE ADJUSTMENT (CLOCKWISE TO DECREASE)

GND SPAN SPAN ADJUSTMENT (CLOCKWISE TO INCREASE)


GROUND TO
PANEL
XDUCER +

950IS
Y

1 2 XDUCER - NEMA ENCLOSURE AS SPECIFIED 1 2 NEMA ENCLOSURE


B AS SPECIFIED
(OPEN CHASSIS AVAILABLE)
+ 4-20 MA (OPEN CHASSIS
DC-RESISTIVE, FUSED SAFETY BARRIER,
AVAILABLE)
950IS

POSITIVE POTENTIAL, RESPECT TO GROUND, JUMPER FOR LEVEL/RANGE MODE.


SLAVE INPUT
STAHL MODEL No. 9001/01-280/165/00. REMOVE COVER AND MOVE JUMPER
IF RANGE MODE IS REQUIRED.
B O-1O (V1) (SEE INSTRUCTIONS BELOW FOR DETAILS)
GROUND SHIELD AT 3 4 1O-O (V2) 1 LEVEL 1 3 4
CONTROLLER MODE RANGE
END ONLY. (INSTALLED) * MODE
120 V 6O HZ 1 2 24O V 6O HZ
Y B L N G L1 L2 G

TRANSMITTER TRANSMITTER
950 1446 950 1446

G G TO 240 VOLT
TO ASSOCIATED EQUIPMENT O-1O 60HZ AC LINE
TO 120 VOLT
ISOLATED OUTPUT N L2 (6 VA MAX)
(1O MA. MAXIMUM) 6OHZ A. C. LINE
1O-O (OPTIONAL,
L L1
(6 VA. MAXIMUM)
ONLY WHEN
ORDERED)
CONDUIT WITH CABLE. SEE NOTES FOR
DETAILS. (NO OTHER WIRES PERMITTED
APPROVED SEAL IN THIS CONDUIT.) (COLOR CODE SHOWN
IS FOR BELDEN 9182 CABLE. SEE
CABLE PARAMETER DETAILS.) NOTES

NON-HAZARDOUS LOCATION CABLE PARAMETERS


A. USE CONDUIT WITH CABLE INSIDE.
HAZARDOUS LOCATION B. NO OTHER WIRES TO BE IN CONDUIT.
CLASS I, DIV. 1, GROUP C & D SEALED JUNCTION BOX, BY OTHERS. C. UP TO 1OOO FEET- #22 AWG OR GREATER, TWISTED SHIELDED
CLASS II, DIV. 1, GROUP E, F & G CABLE, CAPACITY LESS THAN 6O PICOFARAD PER FOOT,
CLASS III, DIV. 1 B CONNECT BLACK WIRE (-) TO BLACK WIRE INDUCTANCE LESS THAN .2 MICROHENRIES PER FOOT.
B AND YELLOW WIRE (+) TO WHITE WIRE.
Y D. UP TO 25OO FEET- TWIN AXIAL BELDEN 9182 OR EQUAL. (8.8 PICO
W (ABOVE CONNECTIONS FOR BELDEN 9182
CABLE TO TRANSDUCER UNIT) FARADS PER FOOT).

TRANSDUCER, 950 1445, SHOWN


FOR REFERENCE ONLY
CALIBRATION INSTRUCTIONS

64 FOOT CABLE WITH CORD GRIP 1. POSITION THE MAGNET AT THE UPPER LIMIT OF THE ANALOG SPAN
REQUIRED (POSITION A). WHILE READING OUTPUT V1 (i.e. O-1O TO
TRANSDUCER 950 1445-** GROUND), ADJUST THE "MIN.R." ADJUSTMENT SCREW TO READ
1O.OO VOLTS.
** INSERT STROKE LENGTH IN INCHES.
2. CHANGE POSITION OF THE MAGNET TO THE LOWER LIMIT OF THE
UL LISTED INTRINSICALLY SAFE
FOR USE IN HAZARDOUS LOCATIONS: ANALOG SPAN (POSITION B). WHILE STILL READING V1, TURN THE
CLASS I, DIV. 1, GROUP C & D "SPAN" ADJUSTMENT SCREW TO READ O.OO VOLTS.
CLASS II, DIV. 1, GROUP E, F & G A
CLASS III, DIV. 1 3. IF THE 4 TO 20mA OUTPUT IS REQUIRED, DETERMINE WHICH MODE
WHEN USED WITH APPROPRIATE SAFETY BARRIER
OF OPERATION IS REQUIRED AND SELECT THE REQUIRED POSITION
1.13" OF THE MODE JUMPER. LEVEL MODE - CURRENT INCREASES ON
7.81"
RISING LEVEL. RANGE MODE - CURRENT INCREASES ON FALLING
LEVEL. THE 0 TO 10 OR 10 TO 0 VOLT OUTPUTS ARE ALWAYS
3/4-16 THREAD
PRESENT.
4. THE 950 TRANSMITTER IS NORMALLY SHIPPED WITH THE JUMPER IN
MINIMUM LEVEL MODE. THE COVER MUST BE REMOVED BY FIRST REMOVING 4
2.00" NULL BAND RANGE
STAND-OFF SCREWS AND COVER BEFORE CHANGING THE MODE
JAM NUT JUMPER.*

2O 10 0 4
*LEVEL MODE - JUMPER ACROSS THE UPPER TWO PINS - POSITION 1.
POSITION "A" MA. VOLTS VOLTS MA. RANGE MODE - JUMPER ACROSS THE LOWER TWO PINS - POSITION 2.
1.28" DIAMETER 1OO% O%
MAGNET ASSEMBLY UPPER ANALOG RANGE
24 VDC (AT TERMINAL “NOT USED”) WILL NOT SUPPORT ANY
ADDITIONAL LOADS.

.31"
GENERAL INFORMATION
TUBE LENGTH
PRIOR TO INSTALLATION, POWER UP THE SYSTEM TO VERIFY
DECREASING INCREASING
MODE V1 V2 MODE SPAN OPERATION AND TO FAMILIARIZE YOURSELF WITH THE UNIT.
MAXIMUM ACTIVE
GUIDE TUBE
LENGTH OF SEE DRAWING E0198300-B WHEN UL APPROVAL IS REQUIRED ON
316 S.S.
MAGNET MOVEMENT
(STROKE LENGTH TRANSDUCER UNIT.
IN INCHES) .40 DIA.

POSITION "B" THE TRANSDUCER SHOULD BE HANDLED WITH CARE DURING STORAGE
O% 1OO%
LOWER ANALOG RANGE AND INSTALLATION.
4 0 10 20
MA. VOLTS VOLTS MA.

5.00" DEAD BAND

GUIDE TUBE CLOSURE

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 13
12 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Series 950MD Mill-Duty Housing


The series 950 Mill-Duty Housing (950MD) was
designed for applications where mounting a stand-
alone rod style linear displacement transducer
(LDT) is prohibitive. Potential physical damage,
environmental conditions or mounting limitations
are all elements that are involved in specifying a
linear position feedback system that will perform
flawlessly for many years to come. The 950MD
housing has been designed to eliminate all of the
above problems by protecting the LDT from physical
and environmental damage such as temperature,
corrosives, shock & vibration, or dust and debris.

950MD
Additionally, the 950MD offers a simple two point
mounting scheme that can compensate for lateral
and/or horizontal movement of the machine while in
operation. Mounting bolts are provided for both the
trunnion mount and rod ends in either standard steel
or optional Stainless Steel when specified.

The 950MD housing is also perfect for retrofitting


existing cylinders with an LDT providing a
continuous position feedback signal. The 950MD
allows for a convenient way to mount the 950MD diameter trunnion mount bracket to the back cap.
and internal LDT parallel to the cylinder. This The trunnion mount bracket is positioned at the
eliminates the need to tear down and gun drill point where the head and barrel connect. A simple
the cylinder to accommodate an LDT simply for exchange of hardware is all that is necessary to
providing position feedback that had not previously move the trunnion mount bracket to the back cap
been available. and plug the no longer required bracket mounting
holes. When ordering the 3/4” rear rod end option,
The housing may also be of benefit in this same the trunnion mount bracket is not supplied since it
configuration when you have an existing cylinder in would not be required.
operation that does not allow for an easy removal
of the LDT. Old machines and even some existing The actuator rod is supported by two bearings within
machines or newly designed machines did not take the guide tube. The front piston bearing contains a
into consideration the need for continuous position wiper assembly to keep contaminants from entering
feedback. Certain machines may require that the the guide tube. The rear, or movable, bearing
entire cylinder be removed in order to replace the LDT. assembly is manufactured from Rulon®. This high-
temperature polymer material provides low wear
The actuator contains a 1/2” spherical rod end with and smooth operation.
approximately 1” of adjustment (length). This
spherical rod end allows mechanical movement in The transducer magnet is mounted within the rear
a horizontal and/or vertical motion to compensate bearing assembly. The magnet is a 1” O.D. cylinder
for any mechanical slop or misalignment between magnet (SD0410300). The magnet is positioned
the housing and machine. A rear trunnion mount 2” from the end of the transducer hex when the
is provided for mounting either directly in front of actuator is fully retracted and 5” from the end of
the head assembly or on the rear of the head. An the transducer guide tube when the actuator is fully
optional 3/4” spherical rod end can be supplied on extended.
the rear of the unit (see drawing for details).
The back cap is supplied with threaded and plugged The 950MD is designed to incorporate an LDT which
holes that allow for field installation of the 3/4” has a minimum 2” Null Zone and 5” Dead Band.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 13
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

950MD Mill-Duty Housing

Due to the fact that the standard Mill-Duty Housing


has a mechanical stroke identical to the LDT
active stroke, no physical over-stroke exists. If
it is possible that the machine being coupled to
can extend/retract beyond the stroke supplied,
damage to the Mill-Duty Housing and possibly to the
machine might occur. To compensate for this we
call out fully retracted/fully extended over-stroke
dimensions for the Mill-Duty Housing. These values
are essentially the additional stroke length added to
950MD

the Mill-Duty Housing. The reason they are called


out separately is to alert the user that when entering
these areas, they are out of the LDT active stroke
area. If an extended over-stroke is specified, the
LDT must be ordered with a Dead Band of 5” + X
(extended stroke value). If a retracted over-stroke
is specified, the LDT must be specified with a Null
value of 2” + Y (retract over-stroke value).

The Mill-Duty Housing offers either a conduit


entrance for hard wiring directly to the LDT within
the head or an external connector and mate. The
connector attaches to the LDT inside of the housing Optional Optional Water-Cooled Optional
Bellows Boot Head Assembly Stainless Boot
via a small pigtail connector within the head. NPT conduit port for wiring to the LDT or optionally
an MS connector can be installed for the external
Detailed Product Description wiring. Use of the MS connector will require that
and Materials of Construction the LDT also have a connector on it in lieu of a
The 950MD consists of a 304 Stainless Steel body, potted cable. This will allow for a quick connect at
barrel, piston, head and trunnion mount bracket. the LDT head internally and on the 950MD head
externally. The 950MD head is sealed with O-rings
The standard 1/2” diameter rod end with mounting and also contains two threaded air purge openings
bolt, the 3/4” diameter trunnion mounting bolt, and that are plugged but available for use to air cool
some of the optional MS connectors on the head the LDT head with filtered and regulated air. By
are the only items that are not Stainless Steel on the removing the plugs and installing the proper size
standard assembly. This is also true of the optional air fittings, you can cool the head electronics for
3/4” diameter front and rear rod ends with their high temperature applications. An optional Vortex
mounting bolts. These rod ends and all mounting air cooler may also be specified for the head and/or
bolts can be ordered in Stainless Steel as an option. barrel or an optional water jacket for the LDT can be
The 12mm Euro connector options C3 and C4 come supplied. See the 950MD dimension drawings for
standard in Stainless Steel. Consult the factory for further details.
further details.

The 950MD head assembly is removable to allow Consult Factory if installing


installation of a rod style LDT that will screw into
the standard 3/4” - 16 x 1.00 mounting thread. An 950IS into 950MD Housing
optional Metric thread of M18 X 1.5 can also be
supplied upon request. The head contains a 1/2”

14 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

950MD Mill-Duty Housing


housing assembly with provisions to accept an LDT
Applications and all bolts, nuts and mounting hardware required for
The 950MD was originally designed for use in steel a complete installation. There are also several optional
mill applications but has proven to be reliable in many items available.
applications where ruggedness, environmental protection
and ease of mounting are required. Some of these Vortex Air Cooler - The standard 950MD is equipped
applications include: with air purge ports. In many cases, running clean shop
air through the head is sufficient to cool the electronics.
Steel Mills - Tundish car (Tundish height), turret For severe temperature applications a Vortex Air Cooler
height (Caster), hydraulic coil cars, torch cutoff machine may be desired. A Vortex Air Cooler accepts standard
(torchhead monitoring), furnace tilt, electrode positioning, shop air (80 - 100 PSIG). The air is ejected through a
side guide positioning, ladle slide gate positioning, louver generator in a Vortex spin chamber where the air stream
or roof position, etc. revolves in a tube at up to 1,000,000 RPM. In simplest

950MD
terms the inner stream gives off energy in the form of
Foundries, Forging and Casting – Linear transducers heat to the outer stream and the inner stream exits the
with 950MD housings have been used on sand mold opposite end as hot air. The Vortex Cooler is capable of
compactors, furnace or oven doors and material transfer generating air flows as cold as -40° F.
systems.
Protective Boots - To give added protection to the
Injection Molding and Die Casting – Proven effective actuator rod, protective boots are available. These
in monitoring/controlling the position of the clamp and/ boots attach between the end of the Mill-Duty guide tube
or shot cylinder. The two point connection of the 950MD and the end of the actuator rod assembly. The boots
housing allows for a simple retrofit by replacing limit are offered in neoprene coated nylon for most standard
switches with an LDT for position feedback over the applications. They offer -60° F to 250° F operating range
entire range movement. Linear potentiometers can also with resistance to water and oil. Also, silicone coated
be replaced, thus eliminating their problems with drift, fiberglass offers high temperature resistance from -100°
temperature, and short life span. F to 550° F; Teflon-coated fiberglass offers -100° F to
500° F operating range with a high degree of corrosion
Hydraulic Servo Applications - Ideal for installing resistance and optional stainless steel boots for rugged
parallel to hydraulic cylinders including new applications applications.
and retrofits. The major advantage to using the 950MD
housing versus gun drilling the cylinder for an LDT is that Water-Cooled Head Assemblies - In applications where
the cylinder fluid flow is not compromised. If an LDT fails extreme temperatures are present and air cooling is not
within a cylinder it cannot be removed without having to appropriate, water-cooled head assemblies are available.
deal with the hydraulic fluid lines, pressure etc. Some Cooling jackets within the head assembly allow water to
cylinders may be difficult to remove once installed, thus flow around the electronics.
inhibiting the removal of the LDT. The 950MD housing is
typically mounted parallel to the cylinder, the same as a Front and Rear Mount Spherical Rod Ends - In
slave cylinder would be, so removal is greatly simplified applications where two spherical rod ends are required,
under these conditions. rear mount spherical rod ends are available. The 3/4”
rear rod end attaches to a threaded bolt extending from
Lock and Dam Sites - Miter gate and Tainter valve the rear of the head. The 3/4” front rod end is threaded
position feedback systems have both benefited from the into the piston rod. An optional stainless steel version is
950MD and LDT combination. available. Mounting bolts are supplied with both versions.

Gate Position Feedback - For hydro-electric plants, Delrin Liner - Used in longer horizontal applications,
water control structures, water and wastewater treatment typically 60” or longer to prevent wear on the LDT’s
and managing, wickett gate position feedback for Turbine guide tube as the 950MD housing is stroked. The Delrin
speed control. liner is installed inside of the 950MD barrel and prevents
sag of the LDT’s guide tube.
Optional Items
The standard Mill-Duty Housing includes the complete

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 15
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

950MD Mill-Duty Housing


Part Numbering
950MD 12A 0B 0C X X

Active Stroke in Connector Options


Inches Standard 1/2 inch NPT conduit fitting
X None
X (It is suggested to order a quick disconnect connector
Determine the “active” on the LDT) V Vortex air cooler
stroke to be measured
Environmental 10 pin MS connector and mate on side Protective boot - neoprene coated nylon
followed by “A”. C2 of housing (for use with 951, 952, and 953 LDT’s with B1
(-60F to +250F )
connector option E only)
Protective boot - silicone coated fiber glass
5 Pin, 12mm, Euro Connector on Side of Housing (for B2
Fully Retracted C3 (-100F to +550F )
952A /953A w/connector option S only)
Overstroke in Inches 6 Pin, 12mm, Euro Connector on Side of Housing (for Protective boot - teflon coated fiber glass
C4 B3
Insert length of retract overstroke 953D and SSI w/connector option S only) (-100F to +500F )
in inches followed by “B”. If no C5A 10 Pin STD - to 953A 5 Pin Euro R Rear mount spherical rod end 3/4”
950MD

retract overstroke is required, C5D 10 Pin STD - to 953D 6 Pin Euro F Front mount spherical rod end 3/4”
simply insert “0B”.
NC No Head Cover on the 950MD Housing Stainless steel rear mount spherical rod
Special Head cover for LDTs using a water cooled RS end 3/4” with 304 stainless steel mounting
Fully Extended W
jacket. Allows entry and exit of water lines. NOTE: bolt
This option does not support connector option C, C2
Overstroke in Inches or C3.
Stainless steel front mount spherical rod
Insert length of extend overstroke in FS end 3/4” with 304 stainless steel mounting
CGP Cord grip PVDF for cable diameter .1”-.3” bolt
inches followed by “C” If no extend
CGA Cord grip stainless steel for cable diameter .19”-.25”
overstroke is required insert “0C” Delron liner for extended life cycle on
CGB Cord grip stainless steel for cable diameter .25”-.31” L longer horizontal applications (used to
CGC Cord grip stainless steel for cable diameter .31”-.38” protect the LDT’s rod assembly)
SB 304 stainless steel boot
A Barrel air purge

Note 1: Guide tube support brackets are supplied as standard for


strokes of 72” or greater.
Note 2: Special high temperature, abrasion resistant and oil resistant
cables are available. Consult your Customer Service Representative.

950MD Compatibility Guide Accessories


940 Yes Item Part Number
950IS Consult Factory Vortex Cooler 04578009
951 Yes (Must be ordered w/2” Null Zone & 5” Dead Band) Muffler for Cooler 04578010
952 Yes (Must be ordered w/2” Null Zone & 5” Dead Band) Replacement 1/2” Spherical Rod End 04570140
953 Yes (Must be ordered w/2” Null Zone & 5” Dead Band) Guide Tube Support Bracket (See note 1) C0903400
955 See 956 Section Replacement (Male Connector) for Option “C2” Connector 04521407
7330 Consult Factory Female Mating Connector for Option “C2” Connector 04521372
Replacement (Male Connector) for Option “C3” Connector 04521568
950 LDT Cable Assemblies Replacement Piston & Magnet Sub Assembly SD0452400
Item Part Number Replacement Housing bushing & Seal Sub Assembly SD0563300
Cable Assembly with Mate for Option “C” Connector Style, SD0436700L6
6 Feet, (For 950-CP) 951, 952 and 953 LDT Cable Assemblies
Cable Assembly with Mate for Option “C” Connector Style, Item Part Number
SD0436000L6
6 Feet, (For 950A/950TP)
Cable Assembly with Mate for Option “C2”, C5S, and C5D SD0439700L6
Connector Styles, 6 Feet
5 Pin, Straight, Stainless Steel Cable Assembly with Mate for 949013L6
Option “C3” Connector Style, 6 Feet
6 Pin, Straight, Stainless Steel Cable Assembly with Mate for 949031L6
Option “C4” Connector Style, 6 Feet

16 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

950MD Mill-Duty Housing


Standard 950MD

950MD
Mill-Duty with Rear Mount Spherical Rod End

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 17
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

952 BlueOx
Magnetostrictive LDT
for High Shock and Vibration Areas

Gemco brand position sensing products have been


known for survival in harsh industrial environments.
We have taken over twenty years experience in
magnetostrictive linear sensors and married it with
our understanding of rugged industrial sensors to
develop the BlueOx LDT as the industry’s first truly
rugged magnetostrictive linear transducer.

The BlueOx LDT is lab tested and field proven to


stand up to high shock and vibration. With test
results of 2,000 Gs of shock and 30 Gs of random
vibration without false signals or mechanical
damage, the BlueOx LDT is ready to perform on the
most demanding applications.

In addition to its ability to withstand shock and


vibration, the BlueOx LDT is rugged in other ways.
952

Sensing tube construction is welded stainless Specifications


steel, suitable for insertion in 5000 PSI hydraulic Input Voltage
Analog: 13.5 to 30 VDC
Digital: 13.5 to 26.4 VDC, or +/- 15 VDC
cylinders. The electronics are enclosed behind an
Current Draw < 200mA at 15 VDC
aluminum housing with O-ring seals for IP67 indoor
Analog: 0 to 10 VDC or 10 to 0 VDC, 4 to 20mA or 20 to 4mA
applications (Type Nema 6 rating and stainless steel Output Digital: Start/Stop, Control Pulse or Pulse-Width Modulated/
covers and connectors are available as a special Variable Pulse (PWM/VP)

option). Resolution
0.001”
Internal
Analog Output 16 Bit (1 part in 65,535)
The 952 BlueOx is available with Analog, Control Linearity +/-0.05% of Full Scale
Pulse, Variable Pulse or RS422 Start/Stop outputs. +/-0.006% of Full Scale
Repeatability (+/- .002 inch min.)
The 952 is compatible with PLC interface cards
+/-.02% of Full Scale
and our 1746 LDT Interface Card. The 16 bit Hysteresis

resolution analog output is programmable over the Operating Temperature


Head Electronics -40° to 158° F (-40° to 70° C)
entire active stroke length. The units can easily be Guide Tube -40° to 221° F (-40° to 105° C)
changed in the field from a 0 - 10 VDC to a 10 - 0 Operating Pressure 5000 psi Operational, 10,000 psi Spike
VDC or a 4 - 20mA to a 20 - 4mA. As an added Span Length 2” to 168”
feature, the optional differential analog output allows Null Zone 2”
the distance between two magnets to be measured. Dead Band 2.5”
12mm Micro 5 Pin, CE Approved (Analog Only),
The BlueOx, with its high resolution and rugged Connectors 10 Pin 1/4 Turn MS Connector, Potted Pigtail Assembly,
Optional Temposonics II & III Connectors
construction, is at home in heavy duty areas such as
Update Time
lumber mills, steel mills, stamping plants, assembly Analog 1ms (Stroke Lengths 1” to 50”)
2ms (Stroke Lengths 51” to 100”)
automation, material handling, robotics and any 3ms (Stroke Lengths 101” to 150”)
other industry where highly accurate and reliable Digital
4ms (Stroke Lengths 151” to 168”)
Controller Dependent
continuous linear position sensing is needed. IP67
Enclosure
Approvals CE ( Analog 12mm Micro 5 Pin Connector Only )
Specifications are subject to change without notice.
Specifications are based on a typical 36” LDT .

18 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

952 BlueOx
Dimension Drawing

.30 DIA.

METAL CIRCULAR
CABLE
CONNECTOR
PIGTAIL

2.00

1.75 DIA. 3.00

952
COVER &
HEX

.38
3/4-16
X 1.00 THRD.
W/ ESNA JAM NUT
2.00
NULL

VITON O-RING
FOR 1/2" DIA.
TUBE BOSS SEAL.

.31

STROKE

1.28 DIA.
MAGNET

.4O DIA.
TUBE

2.50
DEAD BAND

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 19
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

952A BlueOx
Part Numbering
952A V0 0120 X X E

Analog Null Zone Connector Option


BlueOx X Standard 2 inches. Standard 12mm 5 pin Euro connector
S
Insert non-standard Null Zone over ( CE Approved )*
Output 2 inches. (Add non-standard portion E Environmental MS connector*
N_
V0 0 to 10 VDC of Null length to stroke length to Potted pigtail cable assembly, insert
calculate list price) C_ pigtail length in feet. Example: C6 = 6
V1 10 to 0 VDC
foot cable.
C4 4 to 20mA Stroke Length Threaded metal connector
C2 20 to 4mA T TM
Insert stroke length to 0.1 inch. Enter as (fits MTS - “RB” on Tempo II or III)
D0 Differential 0 to 10 VDC* a four-place number. Example: A 12.0” Non-corrosive Stainless Steel, 12mm
D1 Differential 4 to 20mA* stroke enters as 0120. To convert metric NC 5 Pin Euro Connector and Cover. Use
strokes, multiply millimeter value by cable P/N 949013 straight connector.
*Analog differential output is the
difference between two magnets, 0.03937 for inch value. Consult factory for other connector options.
minimum distance is 2.5”
Dead Band
X Standard 2.5 inches.
Insert non-standard Dead Band over
2.5 inches. (add non-standard portion
D_
of Dead Band length to stroke length
to calculate list price)

Note 1: On unsupported stroke lengths greater than 4 feet, rod


952

support bracket(s) and a special magnet should be used. * If option S or E (environmental connector) is selected, mating
Note 2: Specify magnet as separate line item (standard magnet connector and/or cable assembly must be ordered separately.
is SD0400800).

Wiring Diagram
Option “S”

Use Euro Connector (micro 12 mm single


keyway) cordsets, available from most connector Wiring Diagram Option “E”
manufacturers or purchased from Ametek.

Program Input Power 15 to 30 VDC PIN-OUT FOR STANDARD


(white wire) (brown wire) CIRCULAR CONNECTO
AT TRANSDUCER HEAD

2 1 Position Common PIN- B BLACK


(gray wire) POWER SUPPLY
5 COMMON
3 4 PIN- C RED
+15/+30 VDC
POWER INPUT
Power Supply Common Position
(blue wire) Output PIN- K GRAY
POSITION COMMON
(black wire)
LDT Connector View PIN- E BROWN
POSITION OUTPUT

PIN- F BLUE
PROGRAM INPUT

PIN- A WHITE
NO CONNECTION

PIN- G ORANGE
NO CONNECTION

PIN- D GREEN
NO CONNECTION

PIN- H YELLOW
2nd POSITION COMMON

PIN- J PURPLE
2nd POWER SUPPLY
COMMON

20 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

952CP BlueOx
Part Numbering
952CP 0120 X X E

Control Pulse Null Zone Connector Option


BlueOx X Standard 2 inches. E Environmental MS connector*
Insert non-standard Null Zone over Potted pigtail cable assembly, insert
2 inches. (Add non-standard portion C_ pigtail length in feet. Example: C6 = 6
N_
of Null length to stroke length to foot cable.
calculate list price)

Stroke Length Dead Band


Insert stroke length to 0.1 inch. Enter as X Standard 2.5 inches.
a four-place number. Example: A 12.0” Insert non-standard Dead Band over
stroke enters as 0120. To convert metric 2.5 inches. (add non-standard portion
D_
strokes, multiply millimeter value by of Dead Band length to stroke length
0.03937 for inch value. to calculate list price)

* If option E (environmental connector) is selected, mating


connector and/or cable assembly must be ordered separately.

Note 1: On unsupported stroke lengths greater than Wiring Diagram


4 feet, rod support bracket(s) and a special magnet

952
should be used. PIN-OUT FOR STANDARD
CIRCULAR CONNECTOR
Note 2: Specify magnet as separate line item AT TRANSDUCER HEAD

(standard magnet is SD0400800).


PIN-C RED
+15 TO +26 VDC
POWER SUPPLY
PIN-B BLACK
POWER SUPPLY
COMMON
PIN-J PURPLE
-15 VDC FOR BIPOLAR
POWER SUPPLY*
PIN-K GRAY
+INTERROGATION

PIN-A WHITE
-INTERROGATION

PIN-F BLUE
+GATE

PIN-E BROWN
-GATE

PIN-D GREEN
NO CONNECTION

PIN-G ORANGE
NO CONNECTION

PIN-H YELLOW
NO CONNECTION
* FOR UNIPOLAR POWER SUPPLY, IT IS RECOMMENDED
TO CONNECT THIS WIRE TO POWER SUPPLY COMMON

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 21
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

952VP BlueOx
Part Numbering
952VP 0120 X X E I 001

Variable Pulse Dead Band Interrogation Mode


BlueOx Standard 2.5 inches. Internal Interrogation
X I
Insert non-standard Dead Band over E IExternal Interrogation
Stroke Length 2.5 inches. (add non-standard portion
D_
Insert stroke length to 0.1 inch. Enter as of Dead Band length to stroke length
a four-place number. Example: A 12.0” to calculate list price) Recirculations Required
stroke enters as 0120. To convert metric 001 (standard) to 127
strokes, multiply millimeter value by Connector Option
0.03937 for inch value. E Environmental MS connector*
Potted pigtail cable assembly, insert
Null Zone C_ pigtail length in feet. Example: C6 = 6
foot cable.
X Standard 2 inches.
Threaded metal connector
Insert non-standard Null Zone over T TM
(fits MTS - “RB” on Tempo II or III)
2 inches. (Add non-standard portion
N_
of Null length to stroke length to Consult factory for other connector options.
calculate list price)

* If option E (environmental connector) is selected, mating


connector and/or cable assembly must be ordered separately.
952

Note 1: On unsupported stroke lengths greater than


4 feet, rod support bracket(s) and a special magnet
should be used.
Note 2: Specify as magnet separate line item
(standard magnet is SD0400800).

Wiring Diagram
PIN-OUT FOR STANDARD
CIRCULAR CONNECTOR
AT TRANSDUCER HEAD

PIN- C RED
+15 TO +26 VDC
POWER SUPPLY
PIN- B BLACK
POWER SUPPLY
COMMON
PIN- J PURPLE
-15 VDC FOR BIPOLAR
POWER SUPPLY*
PIN- K GRAY
+INTERROGATION

PIN- A WHITE
-INTERROGATION

PIN- F BLUE
+GATE

PIN- E BROWN
-GATE

PIN- D GREEN
NO CONNECTION

PIN- G ORANGE
NO CONNECTION

PIN- H YELLOW
NO CONNECTION
* FOR UNIPOLAR POWER SUPPLY, IT IS RECOMMENDED
TO CONNECT THIS WIRE TO POWER SUPPLY COMMON

22 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

952RS BlueOx
Part Numbering
952RS 0120 X X E

RS422 Start/Stop Dead Band


with Interrogation Standard 2.5 inches.
X
Start Sequence Pulse
BlueOx Insert non-standard Dead Band over
2.5 inches. (add non-standard portion
D_
of Dead Band length to stroke length
Stroke Length to calculate list price)
Insert stroke length to 0.1 inch. Enter as
a four-place number. Example: A 12.0” Connector Option
stroke enters as 0120. To convert metric
E Environmental MS connector*
strokes, multiply millimeter value by
0.03937 for inch value. Potted pigtail cable assembly, insert
C_ pigtail length in feet. Example: C6 = 6
foot cable.
Null Zone Threaded metal connector
T TM
(fits MTS - “RB” on Tempo II or III)
X Standard 2 inches.
Consult factory for other connector options.
Insert non-standard Null Zone over
2 inches. (Add non-standard portion
N_
of Null length to stroke length to
calculate list price)

* If option E (environmental connector) is selected, mating


connector and/or cable assembly must be ordered separately.

952
Note1: On unsupported stroke lengths greater than
4 feet, rod support bracket(s) and a special magnet
should be used. Wiring Diagram
Note 2: Specify magnet as separate line item
(standard magnet is SD0400800). PIN-OUT FOR STANDARD
CIRCULAR CONNECTOR
AT TRANSDUCER HEAD

PIN-C RED
+15 TO +26 VDC
POWER SUPPLY
PIN-B BLACK
POWER SUPPLY
COMMON
PIN-J PURPLE
-15 VDC FOR BIPOLAR
POWER SUPPLY*
PIN-K GRAY
+INTERROGATION

PIN-A WHITE
-INTERROGATION

PIN-F BLUE
+GATE

PIN-E BROWN
-GATE

PIN-D GREEN
NO CONNECTION

PIN-G ORANGE
NO CONNECTION

PIN-H YELLOW
NO CONNECTION
* FOR UNIPOLAR POWER SUPPLY, IT IS RECOMMENDED
TO CONNECT THIS WIRE TO POWER SUPPLY COMMON

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 23
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

952QD BlueOx Magnetostrictive


LDT with Quadrature Output
The BlueOx Quadrature is a magnetostrictive linear
displacement transducer (LDT) for continuous
machine positioning in a variety of industrial
applications. The quadrature output makes it
possible for customers to have a direct interface to
virtually any incremental encoder input or counter
card, eliminating costly absolute encoder converters
and special PLC interface modules.

The BlueOx Quadrature LDT is lab tested and field


proven to stand up to high shock and vibration
without effect. With test results of 2,000 Gs of shock
and 30 Gs of random vibration without false signals
or mechanical damage, the BlueOx Quadrature
LDT is ready to perform in the most demanding
applications.

The BlueOx Quadrature LDT can be ordered with


1 to 9999 cycles per inch of output resolution Specifications
and the position data is absolute. The transducer
952

Input Voltage 13.5 to 26.4 VDC


features an input to re-zero the probe “on the fly”. < 200mA at 15 VDC
Current Draw
Another unique feature is the “burst” mode. An
Output Quadrature Output A+, A-, B+, B-, Z+, Z-.
input on the transducer triggers a data transfer Line Drivers: 5V or Input Power
of all the incremental position data relative to the Inputs 10 to 30 VDC
transducer’s absolute zero position. This can be Resolution 0.001”
used to achieve absolute position updates when Linearity <.05% (+/- .002” Min)
power is restored to the system. 0.001% of Full Stroke (+/- .002” Min.)
Repeatability
Hysteresis +/-.02% of Full Scale
The BlueOx Quadrature is shipped from the factory
Operating Temperature
pre-calibrated and ready for installation. In addition Head Electronics -40° to 155° F (-40° to 70° C)
-40° to 220° F (-40° to 105° C)
to its ability to withstand shock and vibration, Guide Tube

the BlueOx Quadrature is rugged in other ways. Operating Pressure 5000 PSI Operational, 10,000 PSI Spike

Sensing tube construction is welded stainless Span Length 2” to 168”

steel, suitable for insertion in 5,000 PSI hydraulic Null Zone 2.0”
cylinders. Dead Band 2.5”

Connectors 1/4 Turn MS Connector Standard. Potted Pigtail Assembly


Available Optionally
The electronics are enclosed behind an aluminum
Approx. 1ms for 1” to 50”
housing with O-ring seals. The BlueOx Quadrature Update Time
Approx. 2ms for 51” to 100”
LDT, with its rugged construction, is at home in Approx. 3ms for 101” to 150”
Approx. 4ms for 151” to 168”
heavy duty areas such as lumber mills, steel mills, IP67
Enclosure
stamping plants and any other harsh environment
Specifications are subject to change without notice.
where accurate and reliable continuous linear Specifications are based on a typical 36” LDT .
position sensing is needed.

24 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

952QD BlueOx Magnetostrictive


LDT with Quadrature Output
Dimension Drawing

.38
2.00 2.50
2.00 3.00 STROKE
NULL
METAL CIRCULAR DEAD BAND
CONNECTOR

.30 DIA.

.4O DIA.
TUBE
1.75 DIA.
.31
COVER & 1.28 DIA.
HEX VITON O-RING
CABLE FOR 1/2" DIA. MAGNET
PIGTAIL 3/4-16 TUBE BOSS SEAL.
X 1.00 THRD.
W/ ESNA JAM NUT

952
Wiring Diagram

PIN-OUT FOR STANDARD


CIRCULAR CONNECTOR
AT TRANSDUCER HEAD

PIN- B BLACK
POWER SUPPLY
COMMON
PIN- C RED
+15/+26 VDC
POWER INPUT
PIN- K GRAY
B-

PIN- E BROWN
Z-

PIN- F BLUE
A+

PIN- A WHITE
BURST INPUT

PIN- G ORANGE
A-

PIN- D GREEN
Z+

PIN- H YELLOW
B+

PIN- J PURPLE
ZERO INPUT

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 25
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

952QD BlueOx Magnetostrictive


LDT with Quadrature Output

Part Numbering
952QD 0120 X X E 1000 E F7 M1 V D X

Quadrature Input Options


BlueOx Sinking X None
E (typically used with
sourcing output type)
Stroke Length
Sourcing
Insert stroke length to 0.1 inch. C (typically used with
Enter as a four-place number. sinking output type)
Example: A 12.0” stroke enters as T TTL Level
0120. To convert metric strokes,
multiply millimeter value by
0.03937 for inch value. Quadrature Cycle Output
Frequency Range
F1 10 kHz
Null Zone
F2 25 kHz
X Standard 2 inches.
F3 50 kHz
Insert non-standard Null Zone over
2 inches. (Add non-standard portion F4 75 kHz
N_
of Null length to stroke length to F5 100 kHz
calculate list price)
F6 150 kHz
F7 250 kHz
Dead Band
952

F8 500 kHz
X Standard 2.5 inches. F9 1 MHz
Insert non-standard Dead Band over
2.5 inches. (add non-standard portion
D_ Output Mode
of Dead Band length to stroke length
to calculate list price) X1 quadrature, consult factory
M1
for other output modes

Connector Option
Zero Offset Storage
E Environmental MS connector*
V Volatile (non retentive)
Potted pigtail cable assembly, insert
C_ pigtail length in feet. Example: C6 = 6 Nonvolatile (retentive, 100,000
N
foot cable. storage cycles maximum)

Output Drivers
Output Resolution
D Differential RS422 line driver, TTL compatible
Cycles per inch, maximum internal
Differential line driver
resolution is 0.001 inches 1000 standard L
10 to 30 VDC, V out = V in (LDT Power) -1 Volt
(available range is 0001 through 9999)

* If option E (environmental connector) is selected, mating


connector and/or cable assembly must be ordered separately.

26 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

953A/D/SSI VMAX™ LDT


Mobile Equipment and Stationary Processing
Systems demand absolute accuracy and reliability in
linear position feedback . . . Regardless.

Innovation, proprietary technology and decades of


experience were the key to the development of our 953
VMAX Linear Displacement Transducer.

We know the manufacturing challenges of today are


extreme, so we designed and built a sensor to meet and
exceed these demands, regardless of the application or
environment.

Introducing the 953 VMAX LDT features:


• High Vibration Resistance to 30 Gs (lab tested)
• High Shock Resistance to 1000 Gs (lab tested)
• Wide Input Power Range of 7 to 30 VDC
(no need to specify different models)
• High Accuracy with High Resolution
• Applications Include All Mobile/Stationary Equipment, or
Both with the Same Sensor
• Sensor Lengths up to 300”
• Durability and Reliability Exceeds Competitive Offerings
• Tri-Color Diagnostic LED Indicator Applications Include
• Gives Quick Indication on the Status of the LDT Absolute linear position feedback for equipment and
• Very Low Power Consumption, 1 Watt Typical, Allows process automation in extreme applications.

953
Direct Connection to Display and Control Interface
Modules Process Automation
• Removable Cartridge for Hydraulic Applications • Steel Mills, Primary and Secondary Metals Processing
• Digital Output, Start/Stop, Variable Pulse (PWM), that includes Stamping, Roll Forming and Die-Casting
Control Pulse • Hydraulic & Pneumatic Cylinders
• SSI (Synchronous Serial Interface), 24, 25 or 26 Bit, • Adaptive Housing Options to Withstand Extreme
Binary or Gray Code, Position Update Temperatures and Contaminants
• Analog Output, 0-10 VDC, +/-10 VDC, 0-5 VDC, (Gemco 950MD units)
+/-5 VDC, 4-20mA
• Contaminant Resistant Mobile Equipment
• IP68 Rated • Lumber and Forest Products Processing
• Optional Stainless Steel Cover and Connector • Refuse Collection, Vehicles, Recycling and
• Multi-Magnet Option (Digital Start/Stop only) Compaction
• Off Road

Stationary Machines
• Sawmill, Plastic, Rubber, Injection Molding, Extrusion
Equipment, Material Handling, Nonwoven, Dancers
and Accumulators

Removable
Cartridge

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 27
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

953A/D/SSI VMAX™ LDT


Specifications
953SSI 6 Pin 12mm Euro micro, Standard. Shock 1000 Gs (lab tested) 953SSI Output 24, 25 or 26 Bit, Binary or Gray Code
Connector Integral cable ass'y, 7 Pin or 8 Pin DIN - option IEC 60068-2-27 (optional parity and error bit),
Interface Position Update
Vibration 30 Gs (lab tested)
953D 6 Pin 12mm Euro micro, Standard. IEC 60068-2-6 953D Output RS = RS422 Start/Stop Pulse
Connector Integral cable ass'y, 6 Pin or 8 Pin DIN or 10 Pin VP = RS422 Variable Pulse (PWM),
Interface MS- Optional Internal/External Interrogation
953SSI Update Time Measuring CP = RS422 Control Pulse
5 Pin 12mm Euro micro, Standard Length 300 750 1000 2000 5000mm TP = TTL Start/Stop Pulse
953A Measurements/ 3.7k 3.0k 2.3k 1.2k 0.5k
Connector Integral cable ass'y, 6 Pin or 8 Pin DIN or 10 Pin sec.
Interface MS- Optional 953A Output
Voltage 0-10 VDC, +/-10 VDC, 0-5 VDC, +/-5 VDC
953D Update Time Controller Dependant 4-20mA
Sensor Housing Body length 3.2”, hex base 1 3/4” dia., 3/4”x16x1” Current
and Mounting thread. Aluminum housing standard, stainless 953A Update Time
steel optional. < 2mS Typical 953A Current Output Max Load Resistance: 500 Ohms
Hex
953A Voltage Output Minimum Load Resistance: 2K Ohm
Displacement 1” to 300" Guide Tube Pressure 5,000 psi continuous Output Current: Guaranteed 5mA minimum
(10,000 psi spike) Analog Ripple: ≤1 mV maximum
Dead Band 2.50" (63.5 mm) standard, (2.25” Minimum) Approvals CE (EMC)

Null Zone 2.00" (50.8 mm) standard, (1.5” Minimum) Input Voltage 7 to 30 VDC Hysteresis 0.001”

Enclosure Rating IP68, IEC 600529 Current Draw 1 watt typical*, 40mA at 24 VDC typical Non-linearity < 0.01% or +/- 0.005”, whichever is greater,
(+/- 0.002 Typical)

953SSI English or Metric Units 953A Zero & Span Factory set at Null & Dead Band locations Storage Temperature -40° to 221° F
Resolution Metric: 1, 5, 10, 20 micron (5 micron standard) Adjustability Field re-settable at any location within active stroke (-40° to 105° C)
English: .00005", .0001", .0005", .001"
Consult Factory for Others. 953D Repeatability Equal to Resolution of Controller Operating
953D 953A Repeatability Equal to Resolution Temperature
Resolution Controller Dependant 953SSI Repeatability Equal to Output Resolution Head -40° to 185° F (­-40° to 85° C)
Guide Tube -40° to 221° F (-40° to 105° C)
953A
Resolution Single Magnet Displacement, Consult Factory for Tri-Color LED beside connector/cable exit,
Internal 0.00006” 953SSI Measured Diagnostics
16-Bit Variables Velocity or Differential Operation See 'LED Output Summary Table' on page 31
Output

NOTE: Specifications subject to change and are based on a typical 48” stroke.
*One watt typical at 1ms interrogation time with no recirculations. Faster interrogation times and/or recirculations increase power consumption.

SSI (Synchronous Serial Interface)


Displacement value is encoded into a 24, 25 or 26 Bit
953

format and transmitted at high speeds. Synchronization


in a closed loop system is made easy. A clock pulse train
from a controller is used to gate out sensor data: one bit
of position data is transmitted to the controller per one
clock pulse received by the sensor. The absolute position
data is continually updated by the sensor and converted
by the shift register into serial information. The sensors
fulfill all requirements to the SSI standard for absolute
encoders.

Stainless Steel
Cover and Connector

S Connector Style M Connector Style B Connector Style C Connector Style E Connector Style
5 or 6 Pin Micro, 12mm Euro 6 Pin DIN, Fits MTS D60 8 Pin DIN, Fits Balluff S32 Integral Cable Assembly 10 Pin MS Connector,
7 Pin DIN, Fits MTS D70 (for SSI only) Fits Gemco 951 & 952 Wiring

28 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Analog Part Numbering 953A/D/SSI VMAX™ LDT


953A V0 0120 X X S X
Null Zone
Output
X Standard 2 inches. Connector Option Optional Housing Style
V0 0 to 10 VDC - Mounting Threads
Insert non-standard Null Zone S Standard 5 Pin, 12mm Euro
V1 10 to 0 VDC N
(1.5” Minimum). Raised face hex
V2 -10 to 10 VDC Integral Cable Assembly. Insert length in
This value is called out in inches C_ base (standard) -
feet. Example: C6 = 6 foot cable.
V3 10 to -10 VDC regardless of units of measure Threads will be the
Blank
(i.e. 1.5” Null Zone = N1.5) M 6 Pin DIN, MTS Style D60 same as “Units of
V4 0 to 5 VDC
Measure” unless
V5 5 to 0 VDC B 8 Pin DIN, Balluff S32 specified otherwise.
Units of Measure
V6 -5 to 5 VDC US Threads with
Blank Inches. Environmental 10 Pin MS Connector
V7 5 to -5 VDC R raised face hex
M Metric E compatible w/951 & 952 LDTs w/
C4 4 to 20mA connector option “E”. base
C2 20 to 4mA US Threads with
High Temp., Integral cable assembly F
flat face hex base
Stroke Length Dead Band 200º C Teflon Cable. Insert length in feet.
H_
Example: H6= 6 foot High Temp Teflon Metric Threads with
Insert stroke length to 0.1 inch. Enter as a four-place X Standard 2.5 inches. M raised face hex
number. Example: A 12.0” stroke enters as 0120. Cable.
Insert non-standard Dead base
OR D
Band (2.25” Minimum) Options Metric Threads with
Insert stroke in millimeters to 1mm. Enter as a N
four-place number. Example: 305mm stroke entered This value is called out in X None flat face hex base
as 0305M. Metric length includes metric mounting, inches regardless of units Stainless Steel cover and Sensor cartridge
M18x1.5. Unless Specified Otherwise. of measure (i.e. 2.25” connector. Only available C
S only - No hex base
Dead Band = D2.25) with connector options S,
C, and H.

SSI Part Numbering


953S 0120 VP X X S 1 B S F 1 X
Units of Measure
Blank Inches Data Length Options Optional Housing Style
1 24 Bits X None - Mounting Threads
M Metric
2 25 Bits A Alarm Bit 25, Parity 26 Raised face hex
Stroke Length 3 26 Bits Stainless Steel cover and base (standard) -
1" to 300". Insert stroke length to 0.1 inch. Enter S connector. Only available with Threads will be the
Blank
as a four-place number. Example: A 12.0” stroke connector options S, C and H. same as “Units of
Data Format Measure” unless
enters as 0120.
B Binary specified otherwise.

953
OR
Insert stroke in millimeters to 1mm. Enter as G Gray US Threads with
a four-place number. Example: 305mm stroke R raised face hex
entered as 0305. Metric length includes metric Position Update base
mounting, M18x1.5. Unless Specified Otherwise
S Synchronous US Threads with
F
Null Zone A Asynchronous flat face hex base
X Standard 2 inches. Metric Threads with
Insert non-standard Null Zone Direction M raised face hex
N base
(1.5” Minimum). F Measures Direction Forward
This value is called out in R Measures Direction Reverse Metric Threads with
N
inches regardless of units of flat face hex base
measure (i.e. 1.5” Null Zone V Velocity
Sensor cartridge
= N1.5) C
Resolution only - No hex base

Dead Band 1 .005mm


X Standard 2.5 inches. 2 .01mm
Insert non-standard Dead Band 3 .05mm
D
(2.25” Minimum) 4 .1mm
This value is called out in inches 5 .02mm
regardless of units of measure (i.e.
2.25” Dead Band = D2.25) 6 .002mm
7 .001mm
Connector Option 8 .00005"
S Standard 6 Pin, 12mm Euro 9 .0001"
Integral Cable Assembly. Insert length in feet. Example: C6 = A .0005"
C_
6 foot cable.
B .001"
M 7 Pin DIN, MTS Style D70
B 8 Pin DIN, Balluff S32
Environmental 10 pin MS connector compatible with
E
SDO439700 LXX cable assembly
High Temp., Integral cable assembly 200º C Teflon Cable.
H_ Insert length in feet. Example: H6= 6 foot High Temp Teflon
Cable.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 29
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

953A/D/SSI VMAX™ LDT


Digital, CP and RS Part Numbering
953D RS 0120 X X S X

Output Dead Band Options


Optional Housing Style
CP Control Pulse X Standard 2.5 inches. X None - Mounting Threads
RS RS-422 Start/Stop Pulse Insert non-standard Dead Stainless Steel cover and
D
Band (2.25” Minimum) Raised face hex
TTL Level Start/Stop connector. Only available
S base (standard) -
TP Typically used to replace This value is called out in with connector options S,
Threads will be the
neutered style probes. inches regardless of units C, and H. Blank
same as “Units of
of measure (i.e. 2.25” Measure” unless
Dead Band = D2.25) Connector Option
specified otherwise.
Stroke Length S Standard 5 Pin, 12mm Euro
Null Zone US Threads with
Insert stroke length to 0.1 inch. Enter as a four-place number.
X Standard 2 inches. Integral Cable Assembly. Insert R raised face hex
Example: A 12.0” stroke enters as 0120.
C_ length in feet. Example: C6 = 6 base
OR Insert non-standard Null Zone
Insert stroke in millimeters to 1mm. Enter as a four-place number.
N
(1.5” Minimum). foot cable.
US Threads with
Example: 305mm stroke entered as 0305M. Metric length includes F
This value is called out in inches M 6 Pin DIN, MTS Style D60 flat face hex base
metric mounting, M18x1.5. Unless Specified Otherwise regardless of units of measure
B 8 Pin DIN, Balluff S32 Metric Threads with
(i.e. 1.5” Null Zone = N1.5)
M raised face hex
Environmental 10 Pin MS base
Units of Measure Connector compatible w/951
E Metric Threads with
& 952 LDTs w/connector N
Blank Inches. option “E”. flat face hex base
M Metric Sensor cartridge
High Temp., Integral cable C
assembly 200º C Teflon Cable. only - No hex base
H_ Insert length in feet. Example:
H6= 6 foot High Temp Teflon
Cable.

Digital, VP (PWM) Part Numbering


953D VP 0120 X X S I 001 X

Output Dead Band Options


Standard 2.5 inches.
Optional Housing Style
VP Variable Pulse X X None
953

- Mounting Threads
Insert non-standard Dead Band Stainless Steel cover and
D_ Raised face hex
Stroke Length (2.25” Minimum) connector. Only available
This value is called out in inches S
with connector options S, base (standard) -
Insert stroke length to 0.1 inch. Enter as a
regardless of units of measure C, and H. Threads will be the
four-place number. Example: A 12.0” stroke Blank
(i.e. 2.25” Dead Band = D2.25) same as “Units of
enters as 0120.
Measure” unless
OR
specified otherwise.
Insert stroke in millimeters to 1mm. Enter as Connector Option
a four-place number. Example: 305mm stroke S Standard 6 Pin, 12mm Euro Number of Recirculations US Threads with
entered as 0305M. Metric length includes R raised face hex
Integral Cable Assembly. Insert length in 001 001 (Standard) to 255
metric mounting, M18x1.5. Unless Specified C_ base
feet. Example: C6 = 6 foot cable.
Otherwise
M 6 Pin DIN, MTS Style D60 US Threads with
F
flat face hex base
B 8 Pin DIN, Balluff S32
Metric Threads with
Environmental 10 Pin MS Connector Interrogation Mode M raised face hex
E compatible w/951 & 952 LDTs w/ base
Units of Measure connector option “E”. I Internal Interrogation
Metric Threads with
Blank Inches. E External Interrogation N
flat face hex base
Metric
High Temp., Integral cable assembly
M
200º C Teflon Cable. Insert length in Sensor cartridge
H C
feet. Example: H6= 6 foot High Temp only - No hex base
Teflon Cable.

Null Zone
X Standard 2 inches.
N Insert non-standard Null Zone (1.5” Minimum).
This value is called out in inches regardless of
units of measure (i.e. 1.5” Null Zone = N1.5)

NOTE: Metric LDTs cannot be used with standard 950MD housings.


Consult factory.

30 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

953A/D/SSI VMAX™ LDT

953
953 LED Output Summary

Output 953A 953D 953SSI


Flashing Red Flash memory corrupt Flash memory corrupt Flash memory corrupt
Flashing Red/Green EE memory corrupt EE memory corrupt EE memory corrupt
Flashing Green N/A N/A N/A
Flashing Yellow Communication/programming mode Communication/programming mode Communication/programming mode
Fast Flashing Yellow Programming input held asserted Interrogation input held asserted Clock input held asserted
Solid Red No magnet signal detected No magnet signal detected No magnet signal detected
Green/Red Blip (1s to 0.12s) N/A Max Gain but signal detected and within range Max Gain but signal detected and within range
Solid Green Magnet signal detected and within the Normal probe operation; magnet signal and Normal probe operation; magnet signal
programmed range interrogation pulse detected and SSI clock operational
Solid Yellow Magnet signal detected outside of the No external interrogation pulse detected No SSI clock pulses detected
programmed range
Yellow/Red Blip (1s to 0.12s) N/A N/A SSI clock pulses do not match
LDT SSI data length
Green/Yellow Blip (1s to 0.12s) N/A N/A LDT data not synchronous with controller
(if LDT is programmed for synchronous mode)

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 31
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

953A/D/SSI VMAX™ LDT


Magnets 953A Accessories
Part Number Description Part Number Description Use With Connector

SD0400800 Standard Four Hole Magnet 949011L6 6 Foot, 5 Pin, Straight, 12mm Euro Cable S

SD0480900 Standard Four Hole Magnet, Stainless Steel 949011L12 12 Foot, 5 Pin, Straight, 12mm Euro Cable S

SD0403900 Aluminum Split Magnet 949012L6 6 Foot, 5 Pin, Right Angle, 12mm Euro Cable S

SD0411201 Large Split Magnet, Stainless Steel 949012L12 12 Foot, 5 Pin, Right Angle, 12mm Euro Cable S

SD0411200 Large Split Magnet, Standard SD0553200LXX 6 Pin DIN M

SD0410300 Cylinder Magnet, Standard SD0553300LXX 8 Pin DIN Voltage B

SD0410301 Cylinder Magnet, Teflon Coated SD0553400LXX 8 Pin DIN Current B

M0750500 Non-Ferrous Spacer for Split Magnet SD0400800 Standard 4 Hole Magnet All

M0822400 Non-Ferrous Spacer for Four Hole Magnet Consult factory for complete accessory offerings. XX = Length in Feet.

S .53
953D/953SSI Accessories
Part Number Description Use With Connector

949029L6 6 Foot, 6 Pin, Straight, 12mm Euro Cable S


N .331 TYP.
949029L12 12 Foot, 6 Pin, Straight, 12mm Euro Cable S
S N
.662 TYP. S
N S 949030L6 6 Foot, 6 Pin, Right Angle, 12mm Euro Cable S
N 949030L12 12 Foot, 6 Pin, Right Angle, 12mm Euro Cable S

SD0554500LXX 6 Pin DIN (953D) M

SD0558500LXX 7 Pin DIN (953SSI) M

S SD0554600LXX 8 Pin DIN B


.187
4 PLACES SD0400800 Standard 4 Hole Magnet All
1.29 .31 Consult factory for complete accessory offerings. XX = Length in Feet.

Standard 4 Hole Magnet


953

Standard P/N: SD0400800 SSI Cable Length Limits


Stainless Steel P/N: SD0480900 Baud Rate Max. Cable Length

1 MBd 10 ft. 3m

400 kBd 160 ft. 50 m

300 kBd 320 ft. 100 m

200 kBd 650 ft. 200 m

100 kBd 1300 ft. 400 m

NOTE: The maximum cable length recommendation is 10 meters or 33 feet. Longer cables are available, but
extra care must be taken while handling and installing.

32 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955LC BRIK Magnetostrictive LDT


In A Low Profile Package

The 955LC BRIK is an accurate, programmable zero


and span, non-contact linear position sensor in an
economical, low profile package. The sensor utilizes our
field proven magnetostrictive technology to give absolute
position, repeatable to .01% of the sensing distance.
The 955LC is a cost effective linear sensing solution,
designed for the OEM market.

The transducer can be ordered with 0-10 VDC or


4-20mA. The unit can easily be re-scaled and changed
from a 0-10 VDC to a 10-0 VDC or 4-20mA to a
20-4mA using programming module 955-1412. All units
are provided with a standard quick disconnect connector.
The streamlined anodized aluminum extrusion houses
the sensing element and electronics. The magnet slide
moves over the sensing element that determines the
position and converts it to a readable output.

The 955LC BRIK is a self-contained unit and does not


Specifications
have a can or head assembly. All of the electronics are
Input Voltage 24 VDC +/- 20%
incorporated in the transducer which is less than one
Current Draw 100mA Max.
inch tall. Units can be ordered in span lengths up to 180
inches long in 0.1 inch increments. The magnet slide is 0 to 10 VDC
10 to 0 VDC
Output
designed to move effortlessly along the transducer in 4 to 20mA
20 to 4mA
guide tracks.
+/- 0.05% of Stroke
Linearity

955
or +/- 0.028”, Whichever is Greater
A variety of hardware is available for attaching the Accuracy 0.1% of Full Stroke
magnet slide to the moving portion of the process. The +/- 0.01% of Full Stroke
Repeatability or +/- 0.014”, Whichever is Greater
transducer can be mounted vertically or horizontally
using mounting feet which slide on the lower part of Operating Temperature -20° to 70° C

the extrusion and clamp down when tightened. This Span Length 6” to 180”

packaging provides a compact and easy method of Null Zone 3.00”


mounting for OEM machine builders. Dead Band 1.50”

Connector Standard 4 Pin Micro 12mm Euro Connector


The 955LC BRIK is designed for OEM applications Agency Approvals CE Approved
where economical continuous feedback is necessary. Enclosure IP67
The sensor can be a cost effective replacement to limit Specifcation may change without notice.
switches, proximity sensors, linear potentiometers and
LVDT’s. Applications include presses, blow molding,
injection molding, extrusion, roll positioning, dancer
control and many more.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 33
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955LC BRIK
Part Numbering
955LC V0 0120 Wiring Diagram
Use Euro Connector (micro 12 mm single
Output Stroke Length
keyway) cordsets, available from most connector
V0 0 to 10 VDC Insert stroke to 0.1” as a four-place number, enter manufacturers or purchased from Ametek. Install
V1 10 to 0 VDC 12.0” stroke as 0120; to convert metric strokes,
multiply millimeter value by 0.03937 for inch value. according to the following diagrams:
C4 4 to 20mA
C2 20 to 4mA
No Connection Power 24VDC
Accessories (brown wire)

Item Part Number 2 1


Slide Magnet SD0521800
Floating Magnet SD0522100 3 4
Wide Floating Magnet SD0551500
Output
Ground (black wire)
Mounting Foot SD0522000 (blue wire)
6 Ft., 4 Pin Cable 949001L6 Connector View
12 Ft., 4 Pin Cable 949001L12
6 Ft. Cable; Right Angle Connector 949002L6 Note: The North side of a floating
magnet will face the LDT’s sensing
S
12 Ft. Cable; Right Angle Connector 949002L12
Program Module 955-1412 surface. N
Sensing Surface
955

34 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955 eBRIKTM High Resolution


Magnetostrictive LDT In A Low The transducer can be mounted vertically or horizon-
tally using our mounting feet which slide on the lower
Profile Package part of the extrusion and clamp down when tightened.
The 955 eBrik™ is an accurate, programmable zero and
This packaging provides a compact and easy method of
span, auto-tuning, non-contact linear position sensor in
mounting for machine builders.
an economical, low-profile package. The sensor utilizes
our field-proven Magnetostrictive technology to provide
The 955 eBrik™ is designed for applications where eco-
absolute position, repeatable to .001% of the sensing
nomical continuous feedback is necessary. The sensor
distance. The 955 eBrik™ is a cost effective linear sens-
can be a cost effective replacement to linear potentiom-
ing solution.
eters, limit and proximity sensors.
Applications include presses, blow molding, injection
The streamlined anodized aluminum extrusion houses
molding, extruding, roll positioning, tire press, and many
the sensing element and electronics. The magnet moves
more.
over the sensing element that determines the position
and converts it to a readable output. The 955 eBrik™ is
a self-contained unit and does not have a “can” or head
assembly. All of the electronics are incorporated in the
transducer, which is less than one inch tall.

Units can be ordered in span lengths up to 72 inches


long in 1 inch increments. The slide magnet is designed
to move effortlessly along the transducer in guide tracks,
or a floating magnet assembly can be positioned above
the unit. A variety of hardware is available for attaching
the magnet slide to the moving portion of the process.
The transducer can be ordered with 0 to10 VDC or 4 to
20 mA output.

All units are provided with our standard 5 pin 12mm Euro
Micro connector, mounting feet and magnet assembly.
Mating cables are sold in various lengths and must be Specifications
Input Voltage 24 VDC +/- 20%

955
ordered separately.
Current Draw 1.1w (44 mA typical)

The 955 eBrik™ has a few truly unique features. One 0 to 10 VDC
10 to 0 VDC
feature is the LDT’s auto-tuning capability, the ability to Output 4 to 20 mA
20 to 4 mA
sense the distance between the magnet and the sens-
Less than +/- 0.03% of stroke,
ing surface and adjust its signal strength accordingly. As Non-Linearity or +/- 0.013” whichever is greater
a bonus feature, the 955 eBrik™ offers Programmabil- Resolution 16 Bit (1 part in 65535)
ity, the ability to rescale the Zero and Span positions Update Time 1 ms
or invert the positions in the field. This is an optional Repeatability .001%
feature and must be called out at time of order under the Operating Temperature -40° to 85° C
“Options” field. All units come fully programmed from the Span Length 1” to 72”
factory, are 100% absolute, and do not require repro- Null Zone 2.75”
gramming unless desired. There is a unique diagnostic
Dead Zone 2.75”
that is built into the analog output on every unit. If there
Connectors 12mm Micro 5 Pin
is a loss of magnet, or if the magnet assembly moves
Enclosure IP67
beyond the programmed range, the analog output will
Approvals CE
transmit a fault voltage or current, warning the host con-
Specifcations are subject to change without notice.
troller that it is out of range.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 35
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955 eBRIKTM
Part Numbering
955e V0 0120 E FM X
955 eBrik™ Output Type Stroke Length Units of Measure Magnet Type Options
V0 = 0 to 10 Insert stroke length to 1 inch E = English US inches FM = Floating Magnet (Standard) X = No Options
V1 = 10 to 0 or 25mm. Enter as a four- M = Metric SM = Slide Magnet Top Swivel P = Programmable
C2 = 20 to 4mA place number. Example: SF = Slide Magnet Front Swivel Zero & Span
C4 = 4 to 20mA A 12.0” stroke is entered X = No Magnet
as 0120 (E) or 100mm is
entered as 0100 (M).

Dimension Drawing

All units are provided with mounting feet


and a magnet assembly. The mounting feet
(SD0522000) slide in the grooves on the side
of the extruded housing. When tightened down
with fastening hardware, the mounting brackets
clamp the unit into place.
955

Accessories Wiring Diagram


Item Part Number PIN Number Function Color
Slide Magnet SD0521800 1 +VDC POWER SUPPLY BROWN
Slide Magnet Side Adapter SD0521801 2 PROGRAM* WHITE
Large Float Magnet SD0551500 3 POWER SUPPLY COMMON BLUE
Mounting Foot SD0522000 LDT 4 ANALOG OUT BLACK
6 Ft. Cable - Straight 949019L6 Connector 5 ANALOG COMMON GRAY
12 Ft. Cable - Straight 949019L12 End View
*Optional feature must be specified in the part number at time of order.
6 Ft. Cable - Right Angle 949020L6
12 Ft. Cable - Right Angle 949020L12
Control Arm 955ARMXX (X = Inches)
Rod Ends 04-570252

36 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955S Smart BRIK Magnetostrictive LDT


In A Low Profile Package

The 955S Smart BRIK is an accurate, programmable


zero and span, auto-tuning, non-contact linear position
sensor in an economical, low profile package. The sensor
utilizes our field proven magnetostrictive technology to
give absolute position, repeatable to .01% of the sensing
distance. The 955S Smart BRIK is a cost effective linear
sensing solution.

The streamlined anodized aluminum extrusion houses the


sensing element and electronics. The magnet slide moves
over the sensing element that determines the position
and converts it to a readable output. The 955S Smart
BRIK is a self-contained unit and does not have a can
or head assembly. All of the electronics are incorporated
in the transducer which is less than one inch tall. Units
can be ordered in span lengths up to 180 inches long
in 0.1 inch increments. The magnet slide is designed to
move effortlessly along the transducer in guide tracks or
a floating magnet assembly can be positioned above the
unit.

A variety of hardware is available for attaching the magnet


slide to the moving portion of the process. The transducer
can be mounted vertically or horizontally using our Specifications
mounting feet which slide on the lower part of the extrusion Input Voltage 10 to 30 VDC
and clamp down when tightened. This packaging provides Current Draw 100mA Max.
a compact and easy method of mounting for machine
V0 = 0 to 10 VDC
builders. V1 = 10 to 0 VDC
V2 = -10 to 10 VDC
V3 = 10 to 10 VDC
The transducer can be ordered with 0 to 10 VDC, 4 to V4 = 0 to 5 VDC
Output
20mA, or -10 to 10 VDC output. All units are provided V5 = 5 to 0 VDC
V6 = -5 to 5 VDC
with a standard quick disconnect connector. A unique V7 = 5 to -5 VDC

955
feature is the diagnostic LED that remains green when C4 = 4 to 20mA
C2 = 20 to 4mA
a good magnet signal is present and when in the active
programmed area. The LED turns yellow when the magnet Linearity +/- 0.05% of Full Stroke
is out of the programmed active range but still within the Accuracy +/- 0.1% of Full Stroke
active stroke area. The LED turns red when there is no Repeatability +/- 0.01% of Full Stroke
magnet present or the magnet assembly is out of the Operating Temperature -40° to 158° F (-40° to 70° C)
sensing area. Span Length 4” to 180”
Null Zone 3”
The 955S Smart BRIK is designed for applications where
economical continuous feedback is necessary. The sensor Dead Band 1.5”
can be a cost effective replacement to limit and proximity Connectors 12mm Micro 4 Pin
sensors and linear potentiometers. Applications include Enclosure IP67, IP68 Optional
presses, blow molding, injection molding, extruding, roll Approvals CE, FM Class I, Div 2
positioning and many more. Specifications are subject to change without notice.

As an added benefit, the 955S is FM approved for Class


I, Div 2, Groups A, B, C, D applications when installed
and wired per drawing E0241100 as shown in the manual.
If your application does not require FM Class I, Div 2
approval, wire the 955S using a standard 4 pin Euro
cordset from Ametek or others.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 37
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955S Smart BRIK


Dimension Drawing

Note: The North side of a floating


magnet will face the LDT’s sensing
S

surface. N
Sensing Surface
955

Wiring Diagram
Use Euro Connector Program Input Power 10 to 30 VDC
(white wire) (brown wire)
(micro 12 mm single
keyway) cordsets, available 2 1
from most connector
manufacturers or purchased 3 4
from Ametek. Install
according to the following Ground Output
(blue wire) (black wire)
diagram:
Connector View

38 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955S Smart BRIK


Part Numbering
955S V0 0120 V0

Output Stroke Length Options


V0 0 to 10 VDC Insert stroke to 0.1” as a four-place number, enter 12.0” Leave blank for no options.
V1 10 to 0 VDC stroke as 0120. Wet environment, electronics sealed
OR E
to IP68 rating
V2 -10 to 10 VDC Insert stroke in millimeters to 1mm. Enter as a four-place
V3 10 to -10 VDC number followed by ‘M’. Example: 305mm stroke entered
V4 0 to 5 VDC as 0305M.
V5 5 to 0 VDC
V6 -5 to 5 VDC
V7 5 to -5 VDC
C4 4 to 20mA
C2 20 to 4mA

Accessories
Item Part Number
Slide Magnet SD0521800
Slide Magnet Side Adapter SD0521801
Floating Magnet SD0522100
Wide Floating Magnet SD0551500
Mounting Foot SD0522000
6 Ft., 4 Pin Cable 949001L6
12 Ft., 4 Pin Cable 949001L12
6 Ft. , 4 Pin Cable, Right Angle Connector 949002L6
12 Ft., 4 Pin Cable, Right Angle Connector 949002L12
Control Arm 955ARMXX (X = Inches)
In-Line Programming Unit 955-1409

955
Plastic Rod End 04-570252
FM Accessories
6 Ft., 4 Pin Straight Cable 949024L6
12 Ft., 4 Pin Straight Cable 949024L12
Connector Lock 04-521570
NOTE: FM approved cordset and connector lock must be used and installed per drawing
E0241100 when installing the 955S in Class I, Div 2, Group A, B, C, D applications.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 39
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Gemco 955A BRIK Gen III


The 955A BRIK Gen III is an accurate
programmable, auto-tuning, non-contact, linear
displacement transducer in an economical, low
profile package. The transducer utilizes our field
proven magnetostrictive technology to give absolute
position, repeatable to .006% of the programmable
sensing distance.

The streamlined anodized aluminum extrusion


houses the sensing element and electronics. The
magnet moves over the sensing element that
determines the position and converts it to an analog
output. It can be ordered with a 0 to 10 VDC or
4 to 20mA output.

The 955A BRIK Gen III has a few truly unique


features. The first one is the LDT’s auto-tuning
capability, the ability to sense a magnet other than
the standard slide magnet and adjust its signal
strength accordingly. Another feature is the analog
output is programmable over the entire active
stroke length. The active stroke area of the LDT Specifications
lies between the Null and Dead zones. There is Input Voltage 13.5 to 30 VDC

a diagnostic LED located at the connector end of Current Draw


2.5 Watts Maximum,
120mA @ 15 VDC Typical
the probe that remains green while a good magnet 0 to 10 VDC, 10 to 0 VDC, 4 to 20mA,
signal is present and when the magnet is in the Output 20 to 4mA
programmed stroke area. The LED turns yellow Resolution
Internal 0.001”
when the magnet is out of the programmed active Analog Output 16 Bit (1 part in 65,535)
955

range, but still within the active stroke area. The Linearity +/- 0.05% of Stroke
LED turns red and the output goes to 0 volts on Repeatbility +/- 0.006% of Full Stroke
voltage output units, or 4mA on current output +/- 0.02% of Full Scale
Hysteresis
units when there is no magnet present or when the
Update
magnet is out of the sensing area. 50” or less 1ms (Stroke Lengths 5” to 50”)
51” to 100” 2ms (Stroke Lengths 51” to 100”)
101” to 150” 3ms (Stroke Lengths 101” to 150”)
The unit can easily be changed in the field from a 151” to 180” 4ms (Stroke Lengths 151” to 180”)

0 - 10 VDC to a 10 - 0 VDC or 4 - 20mA to a Operating Temperature -20° to 70° C

20 - 4mA . As an added feature, the optional Span Length 5” to 180”


differential analog output allows the distance Null Zone 3.00”
between two magnets to be measured. Dead Band 2.00”
Green = Power is applied and magnet is present
The 955A BRIK is designed for applications where LED Red = Fault, magnet is in the Dead Band or lost
Yellow = Out of the active programmed range
economical continuous feedback is necessary. The Standard 5 Pin Micro
Connector
sensor can be a cost effective replacement to limit 12mm Euro Connector

switches, proximity sensors, linear potentiometers Approvals CE


and LVDT’s. Applications include presses, Enclosure IP67, IP68 Optional
blow molding, injection molding, extrusion, roll Specifications are subject to change without notice.
Specifications are based on a typical 36” LDT.
positioning, dancer control and many more.

40 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955A BRIK Gen III


Part Numbering

955A V0 0120 X

Output Stroke Length


V0 0 to 10 VDC Insert stroke to 0.1” as a four-place number, enter 12.0”
V1 10 to 0 VDC stroke as 0120.
C4 4 to 20mA OR
Insert stroke in millimeters to 1mm. Enter as a four-place
C2 20 to 4mA number followed by ‘M’. Example: 305mm stroke entered
D0 Differential 0 to 10 VDC* as 0305M.
D1 Differential 4 to 20mA*

Options
X No options.
*Analog differential output is the difference between E Wet environment, electronics sealed to IP68 rating

two magnets. Minimum distance is 2.5”.

Accessories
Wiring Diagram Item Part Number
Slide Magnet SD0521800
Use Euro Connector (micro 12 mm single
Floating Magnet SD0522100
keyway) cordsets, available from most
Wide Floating Magnet SD0551500
connector manufacturers or purchased from
Mounting Foot SD0522000
Ametek. Install according to the following
6 Ft., 5 Pin Cable 949019L6
diagram: 12 Ft., 5 Pin Cable 949019L12

Program Input 6 Ft., 5 Pin Cable; Right Angle Connector 949020L6


Power 10 - 30VDC
(white wire) (brown wire) 12 Ft., 5 Pin Cable; Right Angle Connector 949020L12

955
2 1 Analog Output Common
5 (grey wire)
3 4
Power Supply
Common Output
(blue wire) (black wire)

Connector View

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 41
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Gemco 955D Digital BRIK Gen III

The 955D Digital BRIK Gen III is an accurate


programmable, auto-tuning, non-contact, linear
displacement transducer in an economical, low
profile package. The transducer utilizes our field
proven magnetostrictive technology to give absolute
position, repeatable to .006% of the programmable
sensing distance.

The streamlined anodized aluminum extrusion


houses the sensing element and electronics. The
magnet moves over the sensing element that
determines the position and converts it to either a
control pulse, variable pulse or RS422 Start/Stop
digital output. The 955D is compatible with PLC
Interface Cards like our 2120L1 module and 1746
LTD Interface Card.

The 955D BRIK Gen III has some truly unique


features. The first one is the LDT’s auto-tuning
capability, the ability to sense a magnet other than
the standard slide magnet and adjust its signal Specifications
strength accordingly. Input Voltage 13.5 to 30 VDC
2.5 Watts Maximum,
Current Draw
There is a diagnostic LED located at the connector 120mA @ 15 VDC Typical
end of the probe that remains green while a good Output Control Pulse, Variable Pulse, Stop/Start
magnet signal is present and when the magnet is in Resolution Controller Dependent
the programmed stroke area. The LED turns yellow Linearity +/- 0.05% of Stroke
if no interrogation signal is detected. The LED turns Repeatbility +/- 0.006% of Full Stroke
red when there is no magnet present or when the
955

Hysteresis +/- 0.02% of Full Scale


magnet is out of the sensing area.
Update Controller Dependent

Operating Temperature -20° to 70° C


The 955D BRIK is designed for applications where
5” to 180”
economical continuous feedback is necessary. The Span Length

sensor can be a cost effective replacement to limit Null Zone 3.00”

switches, proximity sensors, linear potentiometers Dead Band 2.00”

and LVDT’s. Applications include presses, Green = Power is applied and magnet is present
LED Red = Fault, magnet is in the Dead Band or lost
blow molding, injection molding, extrusion, roll Yellow = No interrogation signal
positioning, dancer control and many more. Connector
Standard 6 Pin Micro
12mm Euro Connector
Approvals CE

Enclosure IP67, IP68 Optional


Specifications are subject to change without notice.
Specifications are based on a typical 36” LDT.

42 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955D BRIK Gen III

Part Numbering

955D CP 0120 X

Output Stroke Length Options


CP Control Pulse Insert stroke to 0.1” as a four-place number, enter 12.0” X No options.
RS RS422 Start/Stop Pulse stroke as 0120. Wet environment, electronics
OR E
sealed to IP68 rating
Insert stroke in millimeters to 1mm. Enter as a four-place
number followed by ‘M’. Example: 305mm stroke entered
as 0305M.

955D VP 0120 E 001 X

Output Interrogation Mode Options


VP Variable Pulse I Internal Interrogation X No options.
E External Interrogation Wet environment,
E electronics sealed to IP68
rating
Stroke Length Number of Recirculations
Insert stroke to 0.1” as a four-place number, enter 12.0” 001 (Standard) to 127
stroke as 0120.
OR
Insert stroke in millimeters to 1mm. Enter as a four-place
number followed by ‘M’. Example: 305mm stroke entered
as 0305M.

955
Accessories
Item Part Number Wiring Diagram
Slide Magnet SD0521800
Floating Magnet SD0522100
Wide Floating Magnet SD0551500
Mounting Foot SD0522000
6 Ft., 6 Pin Cable 949021L6
12 Ft., 6 Pin Cable 949021L12
6 Ft., 6 Pin Cable; Right Angle Connector 949022L6
12 Ft., 6 Pin Cable; Right Angle Connector 949022L12

Connector View

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 43
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955DQ BRIK Gen III Magnetostrictive LDT


In A Low Profile Package

The 955DQ BRIK is an accurate, auto-tuning, non-


contact linear displacement transducer in an
economical, low profile package with direct quadrature
output.

This new method of interfacing magnetrostrictive


transducers offers an interface as common as
analog but with the speed and accuracy of pulsed
type signaling. The Gemco 955DQ linear transducer
provides quadrature output directly from the transducer
to the controller. The output from the transducer can be
wired directly to any incremental encoder input card,
without the need for a special converter module or a
PLC interface card designed specifically for use with a
pulsed output magnetostrictive transducer.

The streamlined anodized aluminum extrusion houses


the sensing element and electronics. The BRIK with
quadrature output is a self-contained unit and does
not have a can or head assembly. All of the electronics
are incorporated in the transducer which is less than Specifications
one inch deep. The magnet slide is designed to move Input Voltage 13.5 to 30 VDC
effortlessly along the transducer in a guide track or a Current Draw
2.5 Watts Maximum,
120mA @ 15 VDC Typical
floating magnet assembly can be positioned above the
Quadrature Output A+, A-, B+, B-, Z+, Z-
unit. Output Line Drivers: 5V or Input Power
Resolution 0.001”
The 955DQ BRIK has a few truly unique features. First,
Linearity +/- 0.05% of Stroke
the LDT has auto-tuning capability. This is the abiliy to
955

Repeatbility +/- 0.006% of Full Stroke


sense a magnet other than the standard slide magnet
and adjust its signal strength accordingly. Another Hysteresis +/- 0.02% of Full Scale

feature is a diagnostic LED located at the connector end Update


50” or less 1ms (Stroke Lengths 5” to 50”)
of the probe that remains green when a good magnet 51” to 100” 2ms (Stroke Lengths 51” to 100”)
101” to 150” 3ms (Stroke Lengths 101” to 150”)
signal is present and power is normal. The LED turns 151” to 180” 4ms (Stroke Lengths 151” to 180”)
red when there is no magnet present or the magnet
Operating Temperature -20° to 70° C
assembly is out of the sensing area.
Span Length 5” to 180”

The 955DQ LDT can be ordered with 1-9999 cycles per Null Zone 3.00”

inch of output resolution in lengths of 5 to 180 inches. Dead Band 2.00”


The transducer features an input to re-zero the probe LED
Green = Power is applied and magnet is present
Red = Fault, magnet is in the Dead Band or lost
“on-the-fly”. Another unique feature is the “burst” mode.
Standard 12 Pin Micro (Option E)
An input on the transducer triggers a data transfer of all Connector 12mm Euro Connector
the incremental position data relative to the customers or 10 Pin HRS (Option H)

set zero position. This can be used to achieve absolute Approvals CE

position updates when power is restored to the system, Enclosure IP67, IP68 Optional (Connector Option E Only)
eliminating the time consuming need to “re-home” the Specifications are subject to change without notice.
Specifications are based on a typical 36” LDT.
machine.

44 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955DQ BRIK Gen III


Part Numbering
955DQ 0120 E 1000 E F7 X1 N D X

955DQ Quadrature Cycle Output Options


Quadrature Frequency Range X None
A1 1 kHz Wet environment,
A2 2 kHz electronics sealed to
Stroke Length E
A3 5 kHz IP68 rating, connector
Insert stroke to 0.1” as a four-place option E only
number, enter 12.0” stroke as 0120. F1 10 kHz
OR F2 25 kHz
Insert stroke in millimeters to 1mm. Output Drivers
F3 50 kHz
Enter as a four-place number Differential RS422 line driver,
F4 75 kHz D
followed by ‘M’. Example: 305mm TTL compatible
stroke entered as 0305M. F5 100 kHz Differential line driver
F6 150 kHz L 10 to 30 VDC, V out = V in
F7 250 kHz (LDT Power) -1 Volt

F8 500 kHz
F9 1 MHz
Connector Option
H HRS environmental connector
Output Mode
E Euro 12 Pin, 12mm connector
X1 quadrature, consult factory
X1
for other output modes
Dual magnet, difference
Output Resolution D1
between magnets
Cycles per inch, maximum internal
resolution is 0.001 inches 1000 standard
(available range is 0001 through 9999) Zero Offset Storage
V Volatile (non retentive)
Nonvolatile (retentive, 100,000
Input N
storage cycles maximum)
Sinking (typically used with
E
sourcing output type)
Sourcing (typically used with
C Wiring Diagram ( Connector Option H )
sinking output type)
T TTL Level

955
Accessories
10 PIN HIROSE CONNECTOR VIEW
Item Part Number
Slide Magnet SD0521800
Floating Magnet SD0522100
Wide Floating Magnet SD0551500 Wiring Diagram ( Connector Option E )
Mounting Foot SD0522000
6 Ft. Cable (Option H) SD0527700L6 - Obsolete, consult factory
12 Ft. Cable (Option H) SD0527700L12 - Obsolete, consult factory
25 Ft. Cable (Option H) SD0527700L25 - Obsolete, consult factory
6 Ft. 12 Pin (Option E Connector ) 949023L6
12 Ft. 12 Pin (Option E Connector) 949023L12
Control Arm 955ARMXX ( X = Length in Inches )
Plastic Rod End 04-570252
For non-standard lengths, consult factory. 12 PIN CONNECTOR VIEW

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 45
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955A/D/DQ BRIK Gen III


Dimension Drawing

Note: The North side of a floating


magnet will face the LDT’s sensing
S

surface. N
Sensing Surface
955

46 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955C BRIK for Pneumatic Cylinders


The 955C BRIK GEN III has truly unique features. The first
one being the LDT’s auto-tuning capability: the ability to
With the demand for automation greater than ever, the
need to replace limit and zone sensors on pneumatic sense a magnet within the pneumatic cylinder and adjust its
cylinders with continuous feedback has become obvious. signal strength accordingly.
Speeding up and improving your process is what you
need in order to stay competitive. Knowing your exact Another feature is that the analog output is programmable
position at any given moment is essential to that end. over the entire active stroke length. The active stroke area
of the LDT lies between the Null Zone and the Dead Band.
Replace your existing limit sensors with the GEMCO
955C BRIK GEN III for continuous position feedback There is also a diagnostic LED located at the connector to
with your choice of Analog, Digital, or Quadrature minimize setup time and troubleshooting. The LED is green
outputs. The 955C BRIK GEN III senses the magnet in normal operation. Red will indicate no magnet present
located in your existing pneumatic cylinder and uses it to
or that the magnet has moved out of sensing range. Yellow
relay absolute positioning information to the machine’s
is an indication the magnet is out of the programmed active
controller. The 955C BRIK GEN III can be retro-fitted to
cylinders in the field using standard mounting brackets range or if no interrogation signal is detected.
or your own customized solution. The 955C solution has
no moving parts to wear out. Magnetostrictive technol- The enclosure comes standard as IP67; however, up-
ogy is used to “see” through the aluminum extrusion and grading to IP68 is available as an option so the LDT can
detect the position of the magnet mounted inside the be used in wet environments.
cylinder.

Three versions of the 955C BRIK GEN III are available.
The 955CA offers analog output in either voltage or
current with your choice of 0 to 10 VDC, 10 to 0 VDC, 4
to 20mA, or 20 to 4mA. The unit can easily be reconfig-
Note: The Pneumatic cylinder must have a magnet in order
ured in the field from a 0-10 VDC to a 10-0 VDC or 4-20
to work. Each cylinder manufacturer uses different types
mA to a 20-4 mA output.
of magnets. In most cases the cylinder supplier installs the
The 955CD is designed for digital output with choice of magnet so that the South Pole is facing out. To date, we
Control Pulse, Start/Stop Pulse, or Variable Pulse output. have successfully worked with most brands of pneumatic

955
cylinders. Consult AMETEK APT for a list of compatible
The Quadrature output from the 955CDQ allows wiring cylinder manufacturers. Call 800.635.0289 to speak with
directly to any incremental encoder input card, with- a Sales Engineer.
out the need for a special converter module or a PLC
interface card. The 955CDQ can be ordered with 1-9999
cycles per inch of output resolution in lengths of 5 to 180
inches. The transducer features an input to re-zero the
probe “on-the-fly”. Another unique feature is the “burst”
mode. An input on the transducer triggers a data trans-
fer of all the incremental position data relative to the set
zero position. This can be used to achieve
absolute position updates when power is
restored to the system, eliminating the
time-consuming need to “re-home” the
machine.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 47
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Top Mounting Foot


Mounting Options for the 955C Part No. SD0522000
LDT Specifications
SPECIFICATIONS
Input Voltage 13.5 to 30 VDC
Current Draw 2.5 Watts Maximum,
120 mA@15 VDC Typical
Output Analog: 0 to 10VDC, 10 to 0 VDC,
4 to 20 mA, 20 to 4mA.
Digital: Control Pulse, Variable
Pulse, Start/Stop
Quadrature: A+, A-, B+, B-, Z+ ,Z-
Line Drivers: 5V or Input Power
Resolution
Internal: 0.001”
It is recommended to use one mounting
Analog Output: 16 Bit (1 part in 65,535)
bracket on each end and every 3 feet between.
Digital Output: Controller Dependent
Quadrature: 0.001”
Non-Linearity +/- 0.05% of Stroke Side Mounting Foot
Repeatability +/- 0.006% of Full Stroke Part No. SD0559200
Hysteresis +/- 0.02% of Full Scale
Update
Analog
50” or less: 1ms
51” to 100”: 2ms
101” to 150”: 3ms
151” to 180”: 4ms
Digital Controller Dependent
o
Operating Temperature -20o to 70 C
Span Length 5” to 180”
Null Zone 3.00”
Dead Zone 2.00”
LED
955

Tricolor diagnostic LED for communication of


LDT status.
It is recommended to use one pair of mounting
Connector brackets on each end and every 3 feet between.
955CA: Standard 5 Pin Micro 12mm Euro Connector
955CD: Standard 6 Pin Micro 12mm Euro Connector
955C DQ: Standard 12 Pin Micro (option E)
12mm Euro Connector or 10 Pin HRS (option H)
End Mounting Foot
Part No. SD0530600
Approvals CE
Enclosure IP 67
IP 68 Optional
Specifications are subject to change without notice.
Specifications are based on a typical 36” LDT.

48 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955CA Analog BRIK Gen III


Part Numbering

955CA S V0 0120 X

955CA Analog BRIK Gen III Output Type Options


V0 = 0 to 10 VDC
V1 = 10 to 0 VDC Stroke Length X No options
Cylinder Magnet Polarity C4 = 4 to 20 mA
C2 = 20 to 4 mA Insert stroke to 0.1” as a four-place Wet environment, electronics
E
S = South Pole facing LDT - Typical number, enter 12.0” stroke as 0120. sealed to IP68 rating
N = North Pole facing LDT OR
Note: It is important to identify the Insert stroke in millimeters to 1mm.
polarity of the magnet installed in the
Enter as a four-place number
cylinder. Most Pneumatic cylinder
manufactures typically install the followed by ‘M’. Example: 305mm
magnet with the South Pole facing stroke entered as 0305M.
out, but we have experienced both
North and South Pole magnets.

Dimension Drawing

955
Accessories for 955CA Wiring Diagram
Item Part Number
Use Euro Connector (micro 12 mm single keyway) cordsets,
Top Mounting Foot (2 min. required) SD0522000 available from most connector manufacturers or purchased from
Ametek. Install according to the following diagram:
End Mounting Feet - Set includes 2 pieces SD0530600
Program Input Power 13.5 to 30 VDC
(white wire) (brown wire)
Side Mounting Feet - Set includes 4 pieces SD0559200

6 Ft. Cable, Straight Connector 949019L6 2 1 Analog Output


5
Common
(grey wire)
12 Ft. Cable, Straight Connector 949019L12 3 4
Power Supply
6 Ft. Cable, Right Angle Connector 949020L6 Common
(blue wire) Output
(black wire)
12 Ft. Cable, Right Angle Connector 949020L12
Connector View

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 49
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955CD BRIK Gen III


Part Numbering
955CD S CP 0120 X

955CD Output Options


Digital
CP Control Pulse X No options
RS RS422 Start/Stop Pulse Stroke Length Wet environment, electronics
E
Insert stroke to 0.1” as a four-place sealed to IP68 rating
Cylinder Magnet Polarity number, enter 12.0” stroke as 0120.
OR
S = South Pole facing LDT - Typical Insert stroke in millimeters to 1mm.
N = North Pole facing LDT Enter as a four-place number
Note: It is important to identify the followed by ‘M’. Example: 305mm
polarity of the magnet installed in the stroke entered as 0305M.
cylinder. Most Pneumatic cylinder
manufactures typically install the
magnet with the South Pole facing
out, but we have experienced both
North and South Pole magnets.

955CD S VP 0120 E 001 X

Output Interrogation Mode Options


VP Variable Pulse I Internal Interrogation X No options
E External Interrogation Wet environment,
Cylinder Magnet Polarity E electronics sealed to IP68
Stroke Length rating
S = South Pole facing LDT - Typical
N = North Pole facing LDT Insert stroke to 0.1” as a four-place number, enter 12.0”
Note: It is important to identify the Number of Recirculations
stroke as 0120.
polarity of the magnet installed in the
cylinder. Most Pneumatic cylinder OR 001 (Standard) to 127
manufactures typically install the Insert stroke in millimeters to 1mm. Enter as a four-place
magnet with the South Pole facing number followed by ‘M’. Example: 305mm stroke entered
out, but we have experienced both as 0305M.
North and South Pole magnets.
955

Wiring Diagram
Accessories for 955CD
Item Part Number
Top Mounting Foot (2 min. required) SD0522000
End Mounting Feet- Set includes 2 pieces SD0530600
Side Mounting Feet - Set includes 4 pieces SD0559200
6 Ft., 6 Pin Cable 949021L6
12 Ft., 6 Pin Cable 949021L12
6 Ft., 6 Pin Cable; Right Angle Connector 949022L6
12 Ft., 6 Pin Cable; Right Angle Connector 949022L12

For non-standard lengths, consult factory.


Connector View

50 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955CDQ BRIK Gen III


Part Numbering
955CDQ S 0120 E 1000 E F7 X1 N D X

955CDQ Quadrature Cycle Output


Quadrature Frequency Range
A1 1 kHz Options
Cylinder Magnet Polarity A2 2 kHz X No options
A3 5 kHz Wet environment, electronics
S = South Pole facing LDT - Typical
N = North Pole facing LDT
E sealed to IP68 rating,
F1 10 kHz connector option E only
Note: It is important to identify the
polarity of the magnet installed in the F2 25 kHz
cylinder. Most Pneumatic cylinder F3 50 kHz
manufactures typically install the
magnet with the South Pole facing F4 75 kHz Output Drivers
out, but we have experienced both
North and South Pole magnets.
F5 100 kHz Differential RS422 line driver,
D
F6 150 kHz TTL compatible
Stroke Length F7 250 kHz Differential line driver
L 10 to 30 VDC, V out = V in
Insert stroke to 0.1” as a four-place F8 500 kHz (LDT Power) -1 Volt
number, enter 12.0” stroke as 0120. F9 1 MHz
OR
Insert stroke in millimeters to 1mm.
Enter as a four-place number Output Mode
followed by ‘M’. Example: 305mm X1 quadrature, consult factory
X1
stroke entered as 0305M. for other output modes

Connector Option
H HRS environmental connector
Euro 12 Pin, 12mm connector, Zero Offset Storage
E
consult factory for others V Volatile (non retentive)
Nonvolatile (retentive, 100,000
Output Resolution N
storage cycles maximum)
Cycles per inch, maximum internal
resolution is 0.001 inches 1000 standard
(available range is 0001 through 9999)

Wiring Diagram ( Connector Option H )


Input

955
Sinking (typically used with
E
sourcing output type)
Sourcing (typically used with
C
sinking output type)
T TTL Level

10 PIN HIROSE CONNECTOR VIEW

Accessories for 955CDQ


Item Part Number
Top Mounting Foot (2 min. required) SD0522000 Wiring Diagram ( Connector Option E )
End Mounting Feet - Set includes 2 pieces SD0530600
Side Mounting Feet - Set includes 4 pieces SD0559200
6 Ft. Cable (Option H Connector) SD0527700L6 OBSOLETE Consult Factory
12 Ft. Cable (Option H Connector) SD0527700L12 OBSOLETE Consult Factory
25 Ft. Cable (Option H Connector) SD0527700L25 OBSOLETE Consult Factory
6 Ft., 12 Pin (Option E Connector) 949023L6
12 Ft., 12 Pin (Option E Connector) 949023L12

For non-standard lengths, consult factory. 12 PIN CONNECTOR VIEW

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 51
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Gemco 956 BLOK Housing Option


The 956 BLOK is an optional housing for the 955 BRIK
Series of Linear Displacement Transducers. This housing
adds a chamber, magnet and piston.

The streamlined anodized aluminum extrusion


houses the sensing element and electronics. The
piston assembly moves over the sensing element that
determines the position and converts it to a readable
output.

The 956 BLOK is a self-contained unit and does not


have a can or head assembly. All of the electronics are
incorporated in the transducer which is less than 1.5
inches square. Units can be ordered in span lengths up
to 36 inches long in 0.1 inch increments. The piston is
designed to move effortlessly along the transducer. A
variety of hardware is available for attaching the LDT to Shown with optional
Metal Rod End.
the moving portion of the process. All units are provided
with a standard quick disconnect conector.

The transducer can be mounted vertically or horizontally


Specifications
using mounting feet or optional rod ends. The mounting
Because the 956 BLOK is an optional housing for the 955, electrical specifications are dependant
feet slide on the extrusion and clamp down when on the particular 955 sensor. See the 955 BRIK pages for specifications.
tightened. This package style provides a compact and Approvals CE
easy method of mounting for machine builders.
Enclosure IP67 (Optional IP68)
Specifications are subject to change without notice.
The 956 BLOK is designed for applications where
economical continuous feedback is necessary. The
sensor can be a cost effective replacement to limit and Part Numbering
proximity sensors and linear potentiometers. Applications To determine a 956 part number, replace the ‘955’ in a
include presses, blow molding, injection molding, 955 BRIK part number with ‘956’. Typical span lengths
extrusion, roll positioning, wicket gates and many more. range from 6” to 36”. Consult factory for other lengths.

955 -S-V0-0120
956

Accessories
Item Part Number
956 -S-V0-0120-X
Spacer Kit
Mount feet for .45” or .75” mounting SD0545100
Includes two mounting feet & spacers An option signifier from the table below must also be
Metal Rod End, Female for Option”F” 04-570256 added to the end of the part number.
Mounting Foot SD0522000
956 Options
Stainless Steel Rod End 1/4-28 Male for Option ”A” 04-570264
X No Options - Male Piston 1/4” - 28 Threads.
E Wet Environment. Electronics sealed to IP 68 Rating.
F Front Metal Rod End, Female - used with option “X”.
R Rear Metal Rod End (Connector End), Female - used with option “X”.
A Tapped Female Piston Rod 1/4” -28 .
S Stainless Steel Front Rod End used with option “A”.
T Stainless Steel Rear Rod End (Connector End) used with option “A”.

52 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

956 BLOK Housing


Dimensions - Standard 956 Housing with Option X

Dimensions - 956 Housing with F, R, and X Options

Dimensions - 956 Housing with S, T, and A Options

956

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 53
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

7230 HT Digital Probe


Proven Magnetostrictive Sensing Performance
Integrated with a Modbus or ASCII Digital
Multivariable Protocol

The 7230 HT Digital Probe is a new magnetostrictive


level measurement probe from Ametek APT for the
up-stream oil and gas industry where multi-layer and
temperature data is critical to everyday operations.

The 7230 Probe is a level measurement solution that


provides both total and interface levels as well as
temperature readings from up to 5 discreet positions.
All the data is collected by installing a single sensor
through a single process connection, eliminating the
need for multiple sensors and insertion points. The 7230
Series is approved as Explosion Proof (without intrinsic
safety barriers) for Class I, Div. 1 and Zone 1 hazardous
locations.

The 7230 is available with a choice of either Modbus


RTU or ASCII communication protocols. An optional
analog interface module is also available for use with the
Modbus RTU output. This option allows for multivariable Specifications
4-20mA outputs. Enclosure Type Type 4/4X IP66 Approvals
Output Level, Interface, Temperature
RS-485, Modbus RTU FM (US and Canada)
All of this performance is enhanced by Ametek APT’s Signal/Protocol* XP Class I, Div I, Group A, B, C, D, T4
Data Signed, Long, Binary DIP Class II, III, Group E, F, G, T4
patented magnetostrictive design. Magnetostrictive
Range Temp. -40°F to 257°F Process
technology requires no calibration yet provides the -40°F to 158°F Ambient
FM
highest accuracy of any of the most popular level 316SS Probe: 1000 psi max. C US
Pressure Rating, APPROVED
Wetted Parts Float Dependent: Consult Factory
technologies that are currently offered in today’s market. 316LSS
Wetted Parts
The 7230 Probe is no exception, as it exceeds the Probe Length Up to 24 foot, 21” to 288”
high accuracy of the proven 7330 Analog STIK with an Accuracy 0.01% of Span
impressive accuracy of 0.01% of measured span. Power Supply 10 to 30 VDC
40mA @ 30 VDC max.
26mA @ 24 VDC Typical
Product Features Null Zone 9.25”
• Multivariable readings Dead Band 2.75”
• Modbus or ASCII Protocol Specifications are subject to change without notice. Patented.
*7235 also available with TTL, proprietary output signal.
• High accuracy
• Reliable level measurement
7230

• Material’s electrical characteristics and densities do not


affect readings
• Easy to install, no technician needed
• Mixed hydrocarbons will not cause level measurement
errors
• A variety of floats are available

54 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

7230 HT Digital Probe


Part Numbering
723 X X X X LLL Rx Fx XXX H EX

7230 Series Connector Style # of Temp Points Overall Special Mounting


HT Digital Probe D = 3/4” NPT Dual R1 = 1 Sensor Length* EX = FM/CSA
S = 3/4” NPT Single R5 = 5 Sensors
T1 = 1 Sensor
Protocol
1 = Modbus Fittings Mounting Style
5 = Proprietary ASCII E = English # of Floats H = Condulet
M = Metric** F1 = 1 Float
F2 = 2 Floats * Specified in whole 1” increments.
Span* See Dimension Drawing for ranges.
Style/Material
X = 316 Stainless Steel

Dimension Drawing

7230 Wiring Diagram

Accessories 7235 Wiring 7231 Wiring


7230
Item P/N
Float Kit: Level Float, 316SS, 2.05” dia., 0.54sg Float, SD0557200
E-clip & spacer
Float Kit: Interface Float, 316SS, 2.05” dia., 0.96sg Float,
COM

SD0556800
E-clip & spacer
DATA
PWR

Float Kit: Level Float, Nitrophyl 2.0” d x 3.0” h 0.40sg, E-clip & spacer SD0548600
Float Kit: Interface Float (w/Nitro. level float), 316SS, 2.05” dia., SD0557300
0.96sg, E-clip & spacer
Adjustable Tube Coupling: 316SS, 5/8” x 3/4” NPT 04283800
Reducing Bushing: 316SS, 2” x 3/4” NPT 04587241
Analog Interface Board: Modbus RTU to analog (4-20mA) converter 04534047

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 55
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

7330 Pro-Stik II
Intrinsically Safe
Programmable Linear Position Sensor
7330X
The 7330 Pro-Stik II sensor combines the reliability Shown with
optional tube
and resolution of magnetostrictive continuous coupling, bushing
and float kit.
absolute positioning sensing with the Stik sensor
package to create a unique level measuring
instrument.

The magnetostrictive technology is the same


as used in Gemco LDT sensors. Ametek liquid 7330F
Shown with
level sensors have been proven in demanding optional float kit.

applications such as underground leak detection


and inventory management. The 7330 is available 7330X
Shown with
with a rigid 316 stainless steel or flexible PVDF optional tube
coupling and large
materials. split magnet.

All of the electronics are SMT components


integrated into the 5/8” diameter sensing tube. This
breakthrough in package design eliminates the
Specifications
electronics enclosure at the top of the sensor, which
Operating Voltage 13.5 to 30 VDC
reduces the cost and offers greater options for
Loop Impedance (R) 0 to 1000 @ 24 volts
insertion and mounting in tanks and vessels.
Output 4 to 20mA

Continuous position data is provided with resolution Operating Temperature -20° to 70° C

of .014”. The two wire loop powered 4 to 20mA Pressure Rating 1000 psi Max.

intrinsically safe output is field programmable for Resolution 0.025% full scale or 0.02” (whichever is greater)

zero and span via a separate programming pin. The Repeatablity 0.025% full scale or +/-0.020” (whichever is greater)

position data is absolute and can be referenced Accuracy 0.1% or .050” (whichever is greater)
from the top or bottom of the probe. Enclosure:
Material Probe: 316 SS or PVDF
Rating IP68
The rugged, all welded 316 stainless steel Probe Length
Stainless Steel 20” to 288”
construction is ideal for industrial, food processing,
pharmaceutical, sanitary environments and Null Zone 8”

even hazardous areas requiring intrinsically safe Dead Band 2”

protection. Intrisically Safe Barrier


Voc less than or equal to 31 VDC
Isc less than or equal to 165mA

Hazardous Areas Approvals


The sanitary and food grade versions of the Stik FM, CSA
are totally welded, ground and polished, and can be -20° ≤ Tamb ≤ 70° C FM
Class I, II, III, Div. 1 C
APPROVED
US
7330

Groups C, D, E, F, G, T4
easily installed with the Tri-clamp fitting. The 7330S Class I, Div. 2
probe design eliminates unacceptable cracks and Approvals Groups A, B, C, D, T4
Class I, Zone 0, AEx ia IIB T4
crevices and is available in a 3-A CIP version or ATEX
Ex ia IIB T4
food grade finish with a removable float. A variety of NEMKO 04 ATEX 1357X
0344 EX II 1G
floats, magnets, and mounting options are available
to fit virtually any application. Specifications may change without notice. Patented.

56 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

7330 Pro-Stik II
Part Numbering
733 0 X M E LLL F1 XXX X XX

7330 Output Connector Style Fittings # of Floats


Pro-Stik II 0 = 4 to 20mA M = 4 Pin Mini E = English Special Mounting
F1 = 1 Float XX = None
1 = 20 to 4mA R = 1/2” NPT Right Angle M = Metric
D = 3/4” NPT Dual
Style/Material S = 3/4” NPT Single Overall Length*
X = 316 Stainless Steel Span*
ie. 072 = 72” (Min 8” Max ie. 072 = 72”
278”. Max span is equal to Min 18” Max 288”
Consult factory for overall length -10)
other options.
* NOTE: Span and OAL in 1” increments only.
Mounting Style
X = None

Dimension Drawing
MM STYLE
Connector

OVERALL LENGTH (O.A.L.)

7/8-16 UNS-2A

1.00 .625

2.00"
8.00" NULL ZONE SPAN DEAD
BAND

Accessories Wiring Diagram


Item Part Number
Float Kit, 316 SS, 2.05” Diameter w/ E Clip and Spacer 0.54s.g. SD0515000
Loop In -
Float Kit, Nitrophyl, 2.02” Diameter w/ E Clip and Spacer 0.40s.g. SD0536500 (Black wire) Chassis
(Shield for Cable),
Cable Assembly, 4 pin, 6 feet long (M style only) 01533141 1 4 (Green wire for cordset)
7330

Adjustable Tube Coupling 5/8” x 3/4” NPT 04283800


2 3
Junction Box, side mount, N4X with zero & span push buttons SD0536101 Program Input
(White wire) Loop In +
Safety Barrier Single Channel 04517238 (Red wire)
Safety Barrier Dual Channel 04517248 Connector View
Contact Factory for additional drawings.
Meter, 4 1/2 digit display, panel mount, 2 output relays 04541069
Bushing, 3/4” x 2” NPT 316SS 04587241

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 57
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

7330EX/ED Pro-Stik II
Explosion/Flame Proof Design Integrated with
Magnetostrictive Technology

The 7330 EX/ED Series Pro-Stik II takes field proven


magnetostrictive sensing technology and incorporates
features such as explosion/flame proof design and
field programmable span. This is packaged in our
patented Stik design, making the Pro-Stik II ideal
for level monitoring in a variety of liquids and tanks.
Sensors are available in rigid 316 stainless steel up to
24 feet.

The 7330 EX/ED Series Pro-Stik II is a loop powered


explosion/flame proof sensor with a scalable 4 to
20mA span that provides 0.1% accuracy, full scale.
Calibration is not required, although the upper and
lower limits of the Span can be programmed in the
field.

The sensor’s electronics are SMT components


in a 5/8” diameter sensing tube. This packaging
breakthrough improves the environmental seal to the
electronics. Specifications
Operating Voltage 13.5 to 30 VDC

The 316 stainless steel sensor is available with 3/4” Output


Operating Output 4 to 20mA
NPT mounting threads or an optional tube coupling. 3.9mA and 20.1mA, float outside of span
Diagnostic Output
The housing has terminal connections as well as 3.8mA, no signal received
(Note: Diagnostic Tolerance +/- 0.02mA)
Zero/Span push buttons. The stainless steel provides Operating Temperature -40° to 70° C, (-40° to 158° F)
a totally welded construction and may be offered with Pressure Rating 316SS Probe: 1000 psi max.
Float Dependent. Consult Factory.
cathodic protec­tion. 0.025% of span or 0.014”
Resolution
(Whichever is Greater)
0.014” + 0.05% of span typical,
The probe provides a security feature by utilizing a Repeatability
0.014” + 0.4% of span maximum
timing sequence that is used to unlock the probe for Accuracy 0.1% of span or 0.050”
(Whichever is Greater)
programming. This ensures that the span cannot be 8”
Null Zone
accidentally programmed by someone in the field. Dead Band 2”
Enclosure Material Probe: 316 SS
The unique diagnostic output pro­vides continuous Rating IP68

information about the float’s position and passcode Probe Length


Stainless Steel D, S 18” to 288”
protection for programming. * Consult Factory
Approvals

FM (US & Canada)


If The float is... Output C
FM US XP Class I, Div I, Group A, B, C, D, T4
Below set span, but within active region 3.9mA APPROVED DIP Class II, III, Group E, F, G, T4
7330

Above set span, but within active region 20.1mA


Either above or below active range or 3.8mA
signal is lost

A variety of floats and mounting accessories are avail­ Specifications are subject to change without notice. Patented.
able to fit virtually any application.

58 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

7330EX/ED Pro-Stik II
Part Numbering
733 0 X D E XXX F1 XXX H XX

7330 Connector Style Span* Mounting Style


Pro-Stik II D = 3/4” NPT Dual H = Condulet
S = 3/4” NPT Single # of Floats
Output F1 = 1 Float
0 = 4 to 20mA Fittings Special Mounting
1 = 20 to 4mA E = English Overall Length* EX = FM/CSA
M = Metric** Explosion Proof

Style/Material
X = 316 Stainless Steel * Specified in whole 1” increments.
See Specifications for ranges.

Dimension Drawing

XS STYLE

XD STYLE

Accessories Wiring Diagram


Item Part Number
Float Kit, 316 SS, 2.05” Diameter w/ E Clip and Spacer 0.54s.g. SD0515000
Float Kit, Nitrophyl, 2.02” Diameter w/ E Clip and Spacer 0.40s.g. SD0536500 REMOTE SETTING OF SPAN
Cable Assembly, 4 pin, 6 feet long (M style only) 01533141
SPAN

Adjustable Tube Coupling 5/8” x 3/4” NPT 04283800


LOOP
+

Meter, 4 1/2 digit display, panel mount, 2 output relays 04541069


PRGM

7330
LOOP

Bushing, 3/4” x 2” NPT 316SS 04587241


-
ZERO

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 59
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Rod Style LDT Accessories

Part
Description 950IS 952 952QD 953 7230 7330 950MD
Number
Standard 4 Hole Rod Magnet SD0400800
   
Stainless Steel 4 Hole Magnet SD0480900
   
Non-Ferrous Spacer for 4 Hole Magnet M0822400
   
Aluminum Split Mag. Assembly SD0403900
   
Non Ferrous Spacer for Split Magnet M0750500
   
Large Split Magnet Assy for use w/ Rod
Supports (P/N SD0411200)
SD0411200
     
Large Split Mag S.S., Assy for use with
Rod Supports (P/N SD0411200)
SD0411201
     
Cylinder and 950MD Magnet SD0410300
    
Teflon Coated Cylinder Magnet SD0410301
    
Float Kit
Level Float, 316SS, 2.05” dia., 0.54sg
Float, E-clip & spacer
SD0557200

Float Kit
Interface Float, 316SS, 2.05” dia., 0.96sg
Float, E-clip & spacer
SD0556800

Float Kit
Level Float, Nitrophyl, 2.0” d x 3.0” h
0.40sg, E-clip & spacer
SD0548600

Float Kit
Interface Float (w/Nitro. level float),
316SS, 2.05” dia., 0.96sg, E-clip & spacer
SD0557300

Adjustable Tube Coupling
316SS, 5/8” x 3/4” NPT
04283800
 
Reducing Bushing
316SS, 2” x 3/4” NPT
04587241
 
Analog Interface Board Modbus RTU to
analog (4-20mA) converter
04534047

Float Kit
Level Float, 316SS, 2.05” dia., 0.54sg
Float, E-clip & spacer
SD0515000

Float Kit
Level Float, Nitrophyl, 2.0” dia., 0.40sg,
Float & E-clip
SD0548600

Stainless Steel Float
Miniature, .62 SG
04-535090

Stainless Steel Float
 
Misc.

04-535091
Egg Shape, .66 SG
Float and Stop Kit
Contains Float and Clamp
SD0565000

60 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Rod Magnets
Standard 4 Hole Magnet Non-Ferrous Spacer for 4 Hole Magnet
.19 THRU
(4) PLACES AS SHOWN
EQ SPACED ON A .937
BOLT CIRCLE.

S .53

45

N .331 TYP.
S N
.662 TYP. S
N S
N

S
.187
4 PLACES
1.29 .31

.530

1.290
Standard P/N: SD0400800 MATERIAL: ALUMINUM
.250

Stainless Steel P/N: SD0480900


P/N: M0822400

Aluminum Split Magnet Non-Ferrous Spacer for Split Magnet

.25

S .31

.812

.406 .19 DIA. THRU


(2) PLACES

.812
S .53

.234

N
.234
.187
(2) PLACES N N
S S

.56
SLOT

1.290
MAT’L.: ALUMINUM
MAT’L.: ALUMINUM
Misc.

P/N: SD0403900 P/N: M0750500

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 61
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Rod Magnets

Large Split Magnet Cylinder Magnet

S .38 .997 .312


.995
DIA.
1.407

S .75 THRU

.187 THRU
(2 PLACES)

N .406
N N

S S
.53

Standard P/N: SD0410300


2.50 REF.
Teflon Coated P/N: SD0410301

NOTE: USE THIS MAGNET WITH ROD


SUPPORT BRACKET SD0411100

Standard P/N: SD0411200


Stainless Steel P/N: SD0411201

Stainless Steel Float Stainless Steel Float


.555 min. i.d
.555 min. i.d.

stake stake
ring ring
magnet magnet
.125
1.295
2.000
1.245

2.000
1.545 o.d.
spherical
1.610 max. dia. O.D.

over weld bead


2.050 max. dia.
* For use with 952 over weld bead
Misc.

* For use with 952 & 953.


P/N: 04535090
P/N: 04535091

62 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955-956 Accessories
955 Slide Magnet
P/N: SD0521800

955 Slide Magnet


Side Adapter
P/N: SD0521801

955 Floating Magnet


P/N: SD0522100

955 Wide Floating Magnet


P/N: SD0551500

955 Mounting Foot


P/N: SD0522000
Misc.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 63
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

955-956 Accessories
955 Control Arm
P/N: 955ARMXX (X = Inches)

955 Plastic Rod Ends for Control Arms


P/N: 04-570252

956 Optional Optional Metal Rod End


Option “F” & “R” for 956 BLOKs
P/N: 04-570256

956 Optional Stainless Steel Male


Metal Rod End Option “S” & “T”
for 956 BLOKs P/N: 04-570264

In-Line Programming Unit


P/N: 9551409

Battery Operated
Test/Programming Unit

Use with 955e, 955S, 955A, 956S, 956A,


952A with connector option ‘S’,
953A with connector option ‘S’
Misc.

P/N: SD0528811 for Current Unit


P/N: SD0528810 for Voltage Unit

64 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Cable Assemblies
Description and 955e
950IS 950MD 951 952 952QD 953D 953A 953SSI 955LC 955S 955DQ 955D 955A 956 7230 7330
Part Number
7330 Cable
P/N 01533141 
2 Pin Mini 16mm Euro
Molded Cable
P/N 04521210 
4 Pin Micro 12mm Euro
Straight Cable
P/N 949001LXX  
4 Pin Micro 12mm Euro
Right Angle Cable
P/N 949002LXX  
5 Pin Micro 12mm Euro
Straight Cable (shielded)
P/N 949011LXX 1
5 Pin Micro 12mm Euro
Right Angle Cable
(shielded) P/N 949012LXX 1
5 Pin Micro 12mm Euro
Straight Cable
P/N 949019LXX 1  
5 Pin Micro 12mm Euro
Right Angle Cable
P/N 949020LXX 1  
5 Pin Micro 12mm Euro
Straight SS Cable
P/N 949013LXX 2
6 Pin Micro 12mm Euro
Straight SS Cable
P/N 949031LXX 3
6 Pin Micro 12mm Euro
Right Angle Cable
P/N 949032LXX 3
6 Pin Micro 12mm Euro
Straight Cable
P/N 949021LXX 
6 Pin Micro 12mm Euro
Right Angle Cable
P/N 949022LXX 
6 Pin Micro 12mm Euro
Straight Cable
P/N 949029LXX 1 1
6 Pin Micro 12mm Euro
Right Angle Cable
P/N 949030LXX 1 1
7 Pin DIN - M Connector Option
Straight Cable
P/N SD0558500LXX 7
12 Pin Micro 12mm Euro
Straight Cable
P/N 949023LXX 
MTS-6 pin, “M” Option, 7
(Voltage or Current Outputs)
P/N SD0553200LXX 
Balluff-8 pin, “B” Option,
(Voltage Outputs Only)
P/N SD0553300LXX 8
Balluff-8 pin, “B” Option,
(Current Outputs Only)
P/N SD0553400LXX 8
MTS-6 pin, “M” Option,
(Digital Outputs)
P/N SD0554500LXX 7
Balluff-8 pin, “B” Option,
(Digital Outputs)
P/N SD0554600LXX 8
10 Pin Micro 12mm Euro
Straight Cable
P/N SD0527700LXX
OBS
10 Pin Straight 5
4 5 5
Cable Assy
P/N SD0439700LXX      
10 Pin Right Angle
     5 5
4 5
Cable Assy
P/N SD0439701LXX
10 Pin Straight High Temp
Cable Assy
P/N SD0465500LXX 4   
951, 952, 953 Analog Cable
Termination Kit
P/N SD0443803L25  5 5
951, 952, 953 Digital Cable
Termination Kit
P/N SD0443800  5 5
953D Digital Cable
Termination Kit
P/N SD0443804L25 6
Misc.

NOTE: XX = Length in Feet.


1
Option S Connector. 4 Option C2 Connector. 7 Option M Connector.
2
Option C3 Connector. 5 Option E Connector. 8 Option B Connector.
3
Option C4 Connector. 6 Option S Connector.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 65
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Cable Accessories

10 Pin Straight Cable 4, 5 & 6 Pin Micro 12mm 10 Pin Straight Cable
(951, 952, & 953 Connector Option E) Euro Straight Cable (955DQ Connector Option H)
(955, 956, 952A, 953) (OBSOLETE)
1.013
MAX.

1.000 1.69
MAX.

1.760 .37

.58

10 Pin Right Angle Cable 4, 5 & 6 Pin Micro 12mm Universal Mounting Kit
(951, 952, & 953 Connector Option E) Euro Right Angle P/N: SD0441300
(955, 956, 952A, 953)
1.046 1.965
MAX.

.450

.812

2 Pin Mini 16mm 12 Pin Micro 12mm Cable Termination Kit


Euro Molded Cable Euro Straight Cable 951, 952 Digital P/N: SD0443800L25
(950IS) (955DQ Connector Option E) 951, 952 Analog P/N: SD0443803L25
953 Digital P/N: SD0443804L25

2.25

.55

1.00
Misc.

66 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Connector Options
952 Connector Options 953 Connector Options

Option “T”
S Connector Style
Threaded Metal Connector
5 Pin Micro, 12mm Euro
(MTS - “RB” on Tempo II & III)

M Connector Style
Option “M” 6 Pin DIN, Fits MTS D60
1/4 Turn Quick Disconnect Connector 7 Pin DIN, Fits MTS D70 (for SSI only)
(MTS - “MS” on Tempo II & III)

B Connector Style
Stainless Steel Head 8 Pin DIN, Fits Balluff S32
Cover and Connector (Consult Factory)

C Connector Style
Integral Cable Assembly

Stainless Steel Head


Cover and Connector
Misc.

M Connector Style
10 Pin MS, Wired to Replace 951 and 952 LDT’s

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 67
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Typical Installation

2.00
.28 1.25
2 PLACES .28 X 1.03 SLOT

.37
.44 C
L 1.00
NOTES: UNLESS OTHERWISE SPECIFIED 1.00
1. MOUNTING KITS FURNISHED WITH NULL STROKE DEAD
MOUNTING BOLTS. BAND
2. MOUNTING BRACKETS ARE MADE FROM PROBE MOUNTING KIT 1.03
3/16" X 2" X3" STAINLESS STEEL . (P/N 949003)

OPTIONAL
MAGNET
2.00

3/4-16 JAM NUT 2.00


PROBE SUPPLIED W/PROBE
1.75 HEX

.62 1.00 MAGNET MOUNTING


KIT (P/N 949005)

Use mounting kit No. 949-003 which includes the 2.00


1.25
.28
2 PLACES

head “L” bracket (M0748600) and the probe support


bracket (SD0411200). The magnet support bracket
includes the magnet “L” bracket and hardware.
It is important to use the mounting kit hardware
provided, or to follow the instructions below. The
magnet is sold separately. In instances where 1.00 2.00

the magnet will be mounted to a ferrous surface, .50

spacers manufactured of non-ferrous materials,


such as stainless steel, nylon, etc. should be used. .88 .28 X .75 SLOT

The spacer should be designed in such a way that 1.91 2.00

any ferrous surface is no closer than 0.25” from the


magnet. Ferrous material within 0.25” of the magnet
will distort the magnetic flux and adversely affect the .50
unit’s operation. NOTE: WHEN USING ROD SUPPORTS USE MAGNET P/N SD0411200

#6-32 THRU 2 PLACES 2.00 .766 THRU

2.00 .56 THRU

2.00
.937 2.00
.469 1.00
1.00

.25 REF. .37 1.25


.25 REF. .37 1.25 .19 MIN.
.19 MIN. 90 –1/4
90 –1/4

.28 THRU
.28 THRU 1.00 1.00
2.00 REF. 2.00 REF. 2 PLACES
2 PLACES

.62 .62
Misc.

3.00 REF. 3.00 REF.

68 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Typical Installation

In Cylinder Mounting
STANDARD 4-HOLE MAGNET

CABLE NUT 0.5" BORE MINIMUM

O-RING SEAL
MAGNET SPACER

OPTIONAL ROD BUSHING

Low Profile Mounting

Misc.

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com 69
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
AUTOMATION & PROCESS
TECHNOLOGIES

Direct Connectivity

Series Application Gemco Transducer Comments

951CP, VP, RS versions High speed, high accuracy card that delivers
PLC direct input for the Allen
1746L 952CP, VP2, RS versions position data directly to the I/O image table
Bradley SLC 500 Chassis
All 955D digital versions every 300 microseconds.

Display reads in inches or millimeters.


951VP-2110 version when a V1
LDT input module that Selectable BCD, Gray code, or Binary output.
board is specified. 951, 952 or 953 CP,
2120 displays position and acts as Optional analog output to indicate position
RS versions when an L1 board
PLC interface and/or velocity. Optional output board
is specified
provides two relay outputs.
Designed for press shut height. Offers
951VP-2110 version when a V1
programmable bolster offset, zero offset,
board is specified. 951, 952 or 953 CP,
2110 Press shut height monitor movement direction, count direction, scale
RS versions when an L1 board
offset, and negative overshoot. Decreases hit
is specified
to hit setup time and offers over-travel limits.

951CP versions, Automatically adjusts the ram up or down to


1996C Press shut height controller 952CP versions, a pre-programmed shut height value for up to
953CP versions 500 jobs. Optional binary output.

955 (0-10 VDC or 4-20mA), Allows the transducer to have programmable


1995L 951A voltage versions, setpoints throughout the range of the sensor.
(Consult Factory Programmable Limit Switch
952A voltage versions, This unit has multiple program capability and
for 4-20 Input ) 953A voltage versions can expand up to 30 outputs.

Hand-Held Programmer Allows 951 The field programmer allows for changes in
& PC Interface to be programmed in the All 951 output, polarity, span, and calibration in the
951-1405 field transducer.

Allows 951 Allows the user to plug in the hand-held


In Line Hand-Held Cable
to be programmed in the All 951 programmer. In Line Hand-Held Programmer
SD0457900
field Patch Cable, use with Part Number 951-1405

In Line Active Zone The field programmer allows for changes in


Allows 955S & 955A to be 952 with Connector Option S,
Programming Unit output, polarity, span, and calibration in the
programmed in the field 953A, 955A, 955e, 955S, 956A, 956S
955-1409 transducer.

Allows Voltage 955S & 955A


Battery Operated 952A, 953A The field programmer allows for changes in
to be
Test/Programming Unit 955A, 955e, 955S, output, polarity, span, and calibration in the
programmed in
SD0528810 956A, 956S transducer.
the field

Allows Current 955S & 955A 952A, 953A


Battery Operated The field programmer allows for changes in
to be 955A, 955e, 955S,
Test/Programming Unit output, polarity, span, and calibration in the
programmed in 956A, 956S
SD0528811 transducer.
the field
Misc.

70 1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com
Other Solutions
1025 Footswitch Cable & Hose Carriers
• Heavy duty treadle operated foot • All steel or nylon construction
switch • Prevents twisting & wear
• NEMA 1 & 4 • Steel withstands severe hydraulic
• Optional protective cover shock loads
• Single or dual circuit • Nylon resists corrosion and is
• Optional locking latch kit non-conductive
• Optional pneumatic valve installed
in place of electrical switches

1999 Semelex II Safetimeter GEMCO Industrial Brakes


• Two Safetimeters in one; the • AISE rated brakes
same unit can be used to check • Electro-Thrust shoe, magnetic
full or part revolution clutch DC shoe, solenoid AC shoe and
presses hydraulic shoe configurations
• Rugged construction built for • Non-Asbestos Linings
pressrooms; will release a run or • Made in the U.S.A.
E-Stop button to initiate press stop
when signaled
• Redesigned Auto-Flag connects to
the Auto-Hand and is positioned
outside the sensing field or
personnel safety devices
• Heavy-Duty Position/Velocity
Transducer uses industrial



grade magnets for secure
mounting to the base and upper
bolster
• Quick-Charge Battery is built in
and can be fully charged in eight
hours or run off AC power

MADE IN AMERICA

Copyright © 2013 by AMETEK Inc. All Rights Reserved. Made in the USA.

1080 North Crooks Road, Clawson, MI 48017


GTTB B10R
Phone: 248-435-0700 Toll Free: 800-635-0289
2/13 Z144
Email: [email protected] Web: www.ametekapt.com
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com