HS-UK Octopus 900 Brochure
HS-UK Octopus 900 Brochure
c e sso
c
Su he
t nn
to dma
l
Go
OCTOPUS 900
Reliably assess static & kinetic
visual fields
THE OCTOPUS 900 VISUAL FIELD ANALYSER
02 |
Covers all your clinical
needs
The Octopus 900 performs standard white-on-
white threshold testing in just 2-4 minutes. With
its flexible Octopus and HFA-style printouts and its
comprehensive test library for central and peripheral
tests, it covers all your clinical needs.
Cost-effective electronic
records
HFA-STYLE PRINTOUT
| 03
2-IN-1 STATIC & KINETIC PERIMETRY
Top fast-thresholding
strategy
Tendency Oriented Perimetry (TOP) presents a further
optimisation in fast-threshold testing by reducing the
examination time by nearly 80%, to just 2–4 minutes.
The TOP algorithm is a systematic method which
takes the correlation of the threshold values in
neighbouring locations into account.
Since the first test points are presented at a supra-
threshold level, even inexperienced patients quickly
SYSTEMATIC TESTING
understand the nature of the test.
Increased efficiency
The shorter test time enables a more efficient
practice, faster patient throughput and improved
clinical workflow.
04 |
SENSITIVE GLAUCOMA ANALYSIS
Cluster analysis
The sensitive cluster analysis groups visual field
defects along nerve fibre bundles and combines
high sensitivity with good specificity to detect early
glaucomatous changes. Significant defects are
highlighted and the cluster defects can be used for
structural comparison. Cluster analysis is available
in both single field and trend view.
SERIES ANALYSIS
| 05
AUTOMATED EYE-TRACKING
Controlled position
Maintaining the correct pupil position during an
examination is essential for correct identification of
the location of a defect.
If the pupil position changes during stimulus
presentation, due to either shifting of the head or PUPIL POSITION CONTROL
eye movement, the Pupil Position Control pauses
the examination automatically, until the pupil is
re-centred. This stimulus is then repeated later in
the test.
Minimise artefacts
Positioning the pupil in the centre of the trial lens
is essential to prevent lens rim and anatomical
artefacts. Automated Eye-Tracking recognises the
position of the pupil and keeps the pupil centred by
automatically moving the head and chin rest into the
ideal position. AUTOMATED EYE-TRACKING
06 |
TRUE GOLDMANN KINETIC PERIMETRY
Fully-flexible
With the Octopus 900, kinetic vectors can be defined
anywhere and with all the characteristics available in
the manual Goldmann perimeter. Additionally, user-
defined templates help generate fast and reproducible
results when defining standard isopters and mapping
the blind spot, as well as for ptosis, driving standards
and functional vision loss.
Adaptable templates
The Octopus 900 allows you to standardise your
clinical workflow without losing the flexibility to adapt
to individual situations. Your kinetic testing protocols
can be translated into a template to standardise
your methodology. Templates can then be adapted
depending on pathology or patient response, with
vectors added or deleted during the test.
CUSTOM TEMPLATES
| 07
INTEGRATION, NETWORKING & SUPPORT
EyeSuite
Whether you use a Haag-Streit biometer, perimeter,
or imaging system, you always use the same EyeSuite
software. Intuitive and easy-to-use, EyeSuite utilises
the same patient management, preferences, import/
export functionality and back-up process across
all Haag-Streit devices. This simplifies your clinical
processes by shortening the learning curve of your
staff.
08 |
OCTOPUS 900 TRAINING & EDUCATION
Comprehensive suite of
learning management tools
Haag-Streit UK understands the importance of
comprehensive training and education, both in terms
of device operation and clinical applications.
That’s why we have developed an extensive suite
of education and training content, including; on-site
customer training, live events, e-learning courses
and video user guides.
ONLINE COURSES
On-site training
Soon after an Octopus 900 is installed, each
customer is provided with an on-site training
workshop, which is delivered to all key members of
staff.
Workshops are usually facilitated by our Product
Manager, an expert in both the operation and clinical
applications of the Octopus system.
These workshops cover all the areas necessary to
allow you to begin using your device effectively.
This includes; setting-up and calibrating your ON-SITE TRAINING WORKSHOPS
system, entering and amending patient data, patient
positioning, patient testing and result evaluation, as
well as other functions such as creating customised
tests and data exporting.
The information provided in these workshops is
replicated in a handy user guide, which is provided
to each member of your team.
In addition to this guide, short videos detailing each
key area of device operation are available via the
Haag-Streit UK website.
| 09
E-LEARNING & LIVE TRAINING EVENTS
10 |
HAAG-STREIT UK
Unit C
Woodside Industrial Estate
Dunmow Road
Bishop’s Stortford
Hertfordshire
CM23 5RG
(01279) 883842
[email protected]
https://hs-uk.co/Octopus900
© HAAG-STREIT UK 2025
E& OE. July 2025