0% found this document useful (0 votes)
525 views31 pages

JINLI Products Manual

This document discusses Anhui Jinli Electric Tech. Co., Ltd., a leading Chinese manufacturer of surge protection devices (SPDs). It provides an overview of the company's testing facilities and capabilities, lightning protection concepts, product categories including power, PV, and signal SPDs, and the company's achievements and certifications over its history of developing innovative SPD technologies and solutions.

Uploaded by

Milton Cusco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
525 views31 pages

JINLI Products Manual

This document discusses Anhui Jinli Electric Tech. Co., Ltd., a leading Chinese manufacturer of surge protection devices (SPDs). It provides an overview of the company's testing facilities and capabilities, lightning protection concepts, product categories including power, PV, and signal SPDs, and the company's achievements and certifications over its history of developing innovative SPD technologies and solutions.

Uploaded by

Milton Cusco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 31

Providing overvoltage solutions for low voltage system

Improving user electricity reliability

S URGE P ROTECTIVE
Vision
Become the leading enterprises in lightning
protection and the global well-known brand
D EVICE
Mission
Continuously improve electricity safety of users

Value
Mutual undertaking, Mutual creation, Mutual benefit,
Mutual sharing

Scan the QR code and access Anhui Jinli

Address: NO.97-2 Yonghe Road,High-tech Zone,HeFei,Anhui.


Tel:0086-0551-65307363
Fax:0086-0551-65319396
Postcode:230031
http://www.ahjinli.com

The version is subject to change without prior notice.


The company has the final interpretation.
CS2018, 1st edition Anhui Jinli Electric Tech . Co.,Ltd
Company profile

Contents

Company profile 01
Anhui Jinli Electric Tech. Co.,Ltd (hereinafter referred to as Jinli ), located in Hi-tech industrial development zone, Hefei, Anhui province, is
Test equipment 03 a national high-tech enterprise and one of the best innovation enterprises in China's lightning protection industry, with 56000 sq.m. for
R&D, production and office, including 3800 sq.m. for laboratory. The laboratories have the full test capacity compliance with national and
Lightning protec on overview 05
international standards such as GB/T 18802.11/21/31, IEC61643-11/21/31, UL1449 and have been assessed and found eligible to
Lightning strike and harm 05 participate in UL witness data program.
Lightning protec on zones 05
Standards 07 2006/3 The birth of Anhui Golden Power Electronics Co.,Ltd
2008/9 Surge protective devices were 1st used in Luanda railway project in Angola
2009/6 1st manufacturer to offer SPD in 2*300MW cogeneration project
Surge protec ve device 08 2009/11 Achieved the National Hi-tech enterprise certification
Power surge protec ve device 08 2011/5 Renamed to Anhui Jinli Electric Tech. Co.,Ltd
Photovoltaic surge protec ve device 37 2012/8 Participated in formulating China lightning protection GB/T 21714
2012/11 Build the largest enterprise-class test center and MOV material laboratory in east China
PCB type surge protec ve device 39
2014 /4 Passed TUV approval for photovoltaic SPD,
Integrated PCB type surge protec ve device 42 2014 /11 Awarded the best innovative enterprise in lightning protection industry.
Signal surge protec ve device 45 2015/3 "Special intelligent power saving cabinet for PV SPD " came to the market
2016/4 Released new products of photovoltaic surge protective device

SPD backup protector 53 2016/8 Obtained RoHS certificate


2017 /8 Obtained CE certificate and Thayer certificate of DOC;

SPD smart monitoring terminal 56 2018/7 Obtained the eligibility to participate in UL witness test data program.
2018/7 Changed to new logo

Company achievement 59
Based on the concept of "adhering to the original", Jinli is committed to power system security and focuses on the over-voltage
protection of the electrical system. With technical service network, we can provide fast and professional service for users and create a safe
and worry-free electricity environment.

http://www.ahjinli.com 01
Certificates and approval Jinli Electric SPD Specialist Test equipment

FIG.1

Testing hall of surge protective device


Jinli has the test capability compliance with national and
international standards such as GB/T 18802.11/21/31,
IEC61643-11/21/31, UL1449, and has been assessed and found
eligible to participate in UL witness data program

FIG.2

Current impulse generators up to 200kA -


8/20μs and 60kA - 10/350μs
Applied to impulse test for T1 and T2 specified in IEC standard
and TYPE4 specified in UL standards

FIG.3

Combined wave generators


Applied to impulse test for T3 power surge protective device and
type C3 wave signal surge protective device of IEC standards

FIG.4

Aging test device


Accelerated aging test at 115℃ or 85℃、1000h

02 http://www.ahjinli.com http://www.ahjinli.com 03
Test equipment Jinli Electric SPD Specialist Lightning Protection Overview

Lightning strike and harm


As failures in building power systems and b e i n g s . With the extensive use of electronic
FIG.5 equipment are unpleasant and expensive, information products with high precision and low
faultless operation of devices must be ensured v o l t a g e tolerance and the deterioration of
both during normal operation and thunderstorms. meteorological environment, the casualties
Automa c salt spray test chamber Three characteristics of lightning: large and property losses caused by lightning
Environmental test for testing metal materials and their protective current, high voltage and great strikes have been far greater than those
layers against salt spray corrosion instantaneous power. Statistics shows caused by other natural disasters, lightning
there are about 1 billion thunderstorms protection is urgent. The phenomenon
annually in the world, with 30 to 100 that lightning strikes directly to cause
lightning flashes per second and an building or personal injury is called
average of 8 million lightning flashes direct lightning damage. The
per day, which can help to maintain phenomenon that equipment damage is
the electrical balance between caused by electromagnetic pulse
earth and the atmosphere, while generated by lightning is called
FIG.6 they bring great harm to human induced lightning damage.

Thermal stability test device


An important test to ensure the thermal stability and safety of
surge protective device (SPD)

Lightning protec on zones


FIG.7
Concepts of lightning protec on zones
AC/DC ac on load power supply Surge occurring during a thunderstorm is caused impulse current of 8/20 μs waveform.
by direct, nearby or remote lightning strike. Direct or The building is divided into different endangered
To test the ability of withstanding impulse current under actual nearby lightning strike can enter into external zones, which help to define the necessary
operating conditions by supplying specified voltage and nominal
lightning protection system and entrance cable protection measures, in particular the lightning and
discharge current (different electrical angles) on tested samples.
system of the building. The risks caused by impulse surge protection devices and components. Part of an
Current impulse generator is needed to finish the test together
with the action load power supply current are enormous because of large energy of EMC compatible lightning protection zone concept is
lightning. The characteristic parameters of impulse the external lightning protection system (including
current are described in impulse current of 10/350 air-termination system, down-conductor system, earth-
μs wave form, which is defined as the test waveform of termination system), equipotential bonding, spatial
direct lightning protection device according to shielding and surge protection for power supply and
international standards. Electromagnetic induction information technology systems, lightning
FIG.8 of the lightning will cause rise surge in building protection zones are divided into LPZOA-LPZn
distribution system and other associated systems according to the lightning protection zone concept
and equipment, which is far lower than the energy of as described in IEC62305-4:2010, see following
10/700μs surge generator direct lightning, and is therefore described by figure:
Impulse test for 10/700µs waveform of signal surge protective
device

04 http://www.ahjinli.com http://www.ahjinli.com 05
Lightning Protection Overview Jinli Electric SPD Specialist Lightning Protection Overview

Effects on overhead lines

Overhead lines are widely exposed and


When the thundercloud discharges may be struck directly by lightning, thus the
circuits or cables could be partially or fully
to the ground, the powerful lightning
destroyed, thus high surge voltages will enter
current which reaches hundreds of into the equipment connected in the circuit.
thousands of amps enters into the The extent of the damage depends on the
objects from the lightning strike point, intensity of unanticipated lightning and the
and generates high temperature and distance between the strike and equipment.
strong mechanical force.

The flow of lightning in the ground


causes rise in ground potential that vary
according to the current intensity and the
As the lightning current has a great
local earth impedance. A strike will cause a
crest value and steepness and will
very large potential difference so that the
Figure 1.1 Lightning protec on zone overview radiate intense electromagnetic fields,
equipment connected to the affected
the values depend on the distance
networks will be destroyed or severely
from the flash and the connection type.
disrupted.

Zone where the threat is due to the direct Zone protected against direct lightning
lightning flash and the full electromagnetic flashes but where the threat is the full lightning Rise in ground potential
field and where the internal systems may be electromagnetic field. The internal systems Electromagnetic radiation
subjected to full or partial lightning surge may be subjected to partial lightning surge
current. currents.

Direct lightning effects Indirect lightning effects

Zone where the surge current may


be further limited by current sharing and Zone where the surge current is limited
isolated interfaces and/or by additional SPDs
at the boundary. Additional spatial shielding may
by current sharing and isolated interfaces
and /or by SPDs at the boundary. Spatial
Standards
be used to further attenuate shielding may attenuate the lightning
the lightning electromagnetic field. electromagnetic field. As the diversity and importance of transient overvoltage, standards organizations have created specifications for
testing the effects of overvoltage on equipment. The phenomena were first characterized and a series of standardized
waves created (8/20μs、10/350μs current waveforms), then a number of standards defining surge protective device
performance were issued, among them:

Lightning overvoltage protec on


According to IEC 61024-1:2001, lightning Internal lightning protection mainly prevent indirect
protection is divided into external lightning lightning strike through equipotential bonding,
protection and internal lightning protection. External object internal shielding, earth-termination system,
lightning protection mainly prevents direct lightning reasonable wiring, surge protective device and
strike through air-termination, down-conductor, other measures.
earth-termination system and spatial shielding.

06 http://www.ahjinli.com http://www.ahjinli.com 07
Power surge protective device Jinli Electric SPD Specialist Type I surge protective device

JINLI surge protective device adopts the excellent nonlinear component with over-voltage protection. The SPD
has a high impedance and low leakage current when no surge is present, can have a sudden change within
nanosecond time in impedance to a low value in response to a voltage surge, limiting the surge amplitude to the safe Reliable thermal tripping protection
Status indicator: transparent (normal),red (defect)
working range of the equipment, and releasing the surge energy into the ground. Thus, the surge protective device
Discharge current: 15kA (10/350μs)
quickly becomes high impedance, and does not affect the working of the power system. Low voltage protection level
Fast response: action within nanosecond
Optional remote signaling
Test class I + ll

JLSP - BC 15/ /
Auxiliar y function(A:remote signaling;C:counter)

L Protection mode(nP,nP+1,nP+N)
Lightning impulse current Iimp
MOV type SPD(class I+Ⅱ)
JLSP-BC15 JINLI surge protective device
K1

3
SK K2
1 JLSP
inner
structure

2
Green MOV Red

Green (Normal) Red (defect)

Pluggable module inner structure

K1:Over voltage protection K2:Thermal tripping protection Technical parameters


SK:Remote signaling MOV:Metal oxide varistors
Model JLSP-BC15

SPD structure diagram IEC Class Class Ⅰ+Ⅱ


AC network UN (50/60Hz)(V) 230/400 (TN/TT/IT)
Max.continuous operating voltage Uc(V) 385
Lightning impulse current(10/350μs) Iimp(kA) 15
Nominal discharge current(8/20μs) In(kA) 30
AC type surge protective device is used in AC power supply system (50/60Hz) and low-voltage control system to Voltage protection level Up(kV) ≤2.0
protect from lightning strike and transient over-voltage. The maximum continuous operating voltage (Uc): 175V, 275V, Max. backup fuse(A ) 125(gG)
350V, 385V, 440V, 485V, 750V. Response time tA (ns) ≤25
DC type surge protective device is used in all kinds of DC power system, such as industrial control system, Capacity of withstand short circuit (k A) 25
communication system and fire control system with DC voltage of 24V, 48V, 110V, 220V etc. Operating temperature (℃ ) -40~+85
Operating humidity ≤95%(25℃)
Max.cross-sectional area 35mm2multi-strand cord
Certificates CE
Dimensions (1P) (mm) 36 ×90×65
Mounting DIN Rail 35mm
Protection rating IP 20
Housing material PA66
Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 1.5mm2 multi-strand cord / single cord
Status indicator normal:transparent / defect:red
Standards compliance IEC61643-11、GB/T 18802.11

08 http://www.ahjinli.com http://www.ahjinli.com 09
Type I surge protective device Jinli Electric SPD Specialist Type I surge protective device

Reliable thermal tripping protection Reliable thermal tripping protection


Status indicator: transparent (normal), red (defect) Status indicator: transparent (normal), red (defect)
Discharge current: 25kA (10/350μs) Discharge current: 12.5kA (10/350μs)
Low voltage protection level Low voltage protection level
Fast response: action within nanosecond Fast response: action within nanosecond
Optional remote signaling Optional remote signaling
Test class I + ll Test class I + ll

JLSP - BC 25/ / JLSP - BC 680/12.5/ /


Auxiliar y function(A:remote signaling;C:counter)
Auxiliar y function(A:remote signaling;C:counter)
Protection mode (nP,nP+1,nP+N)
Protection mode(nP,nP+1,nP+N) Lightning impulse current Iimp
Lightning impulse current Iimp Max. continuous operating voltage
MOV type SPD(class I+Ⅱ) MOV type SPD(class I+Ⅱ)
JINLI surge protective device JINLI surge protective device

JLSP-BC25 JLSP-BC680/12.5

Technical parameters Technical parameters


Model JLSP-BC25 Model JLSP-BC680/12.5
IEC Class Class Ⅰ+Ⅱ IEC Class Class Ⅰ+Ⅱ
AC network UN (50/60Hz)(V) 230/400 (TN/TT/IT) AC network UN (50/60Hz)(V) 460、277/480、400/690 (TN/TT/IT)
Max.continuous operating voltage Uc(V) 385 Max.continuous operating voltage Uc(V) 680
Lightning impulse current(10/350μs) Iimp(kA) 25 Lightning impulse current(10/350μs) Iimp(kA) 12.5
Nominal discharge current(8/20μs) In(kA) 50 Nominal discharge current(8/20μs) In(kA) 12.5
Voltage protection level Up(kV) ≤2.0 Voltage protection level Up(kV) ≤2.8
Max. backup fuse(A ) 125(gG) Max. backup fuse(A ) 125(gG)
Response time tA (ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature (℃) -40~+85 Operating temperature (℃) -40~+85
Operating humidity ≤95%(25℃) Operating humidity ≤95%(25℃)
Max.cross-sectional area 35mm2multi-strand cord Max.cross-sectional area 35mm2multi-strand cord
Certificates CE Certificates CE
Dimensions (1P) (mm) 36 ×90×65 Dimensions (1P)(mm) 36×90×65
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PA66 Housing material PA66
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:transparent / defect:red Status indicator normal:transparent / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

10 http://www.ahjinli.com http://www.ahjinli.com 11
Type I surge protective device Jinli Electric SPD Specialist Type II surge protective device

Reliable thermal tripping protection


Status indicator: transparent (normal), red (defect) Reliable thermal tripping protection
Discharge current: 12.5kA (10/350μs) Status indicator: green (normal), red (defect)
Low voltage protection level Max. discharge current: 40kA (8/20μs)
Fast response: action within nanosecond Low voltage protection level
Optional remote signaling Fast response: action within nanosecond
Test class I + ll Optional remote signaling
Apply to industrial field, PV system and wind turbine system Pluggable design

JLSP - BC 750/12.5/ /
Auxiliar y function(A:remote signaling;C:counter) JLSP - GA 175/40/ /
Protection mode (nP,nP+1,nP+N) Auxiliar y function(A:remote signaling;C:counter)
Lightning impulse current Iimp Protection mode (nP,nP+1,nP+N)
Max. continuous operating voltage Max. discharge current Imax
MOV type SPD(class I+Ⅱ) Max. continuous operating voltage
JLSP-BC750/12.5 JINLI surge protective device
AC series
JINLI surge protective device

JLSP-GA175/40

36 54 72 62
18 18 18 18

45.5
90

90

90
90
COM NC NO COM NC NO COM NC NO COM NC NO

Technical parameters Technical parameters


Model JLSP-BC750/12.5 Model JLSP-GA175/40
IEC Class Class Ⅰ+Ⅱ IEC Class Class Ⅱ
AC network UN (50/60Hz)(V) 460、277/480、400/690 (TN/TT/IT) AC network UN (50/60Hz)(V) 120 (TN-S)
Max.continuous operating voltage Uc(V) 750 Max.continuous operating voltage Uc(V) 175
Lightning impulse current(10/350μs) Iimp(kA) 12.5 Nominal discharge current(8/20μs) In(kA) 20
Nominal discharge current(8/20μs) In(kA) 12.5 Max. discharge current(8/20μs) Imax(kA) 40
Voltage protection level Up(kV) ≤2.8 Voltage protection level Up(kV) ≤1.2
Max. backup fuse(A ) 125(gG) Max. backup fuse(A ) 100(gG)
Response time tA (ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature (℃) -40~+85 Operating temperature (℃) -40~+85
Operating humidity ≤95%(25℃) Relative humidity ≤95%(25℃)
Max.cross-sectional area 35mm2multi-strand cord Max.cross-sectional area 35mm2 multi-strand cord
Certificates CE Certificates CE
Dimensions (1P) (mm) 36×90×65 Dimensions (1P) (mm) 18×90×62
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PA66 Housing material PBT
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 2
1.5mm multi-strand cord / single cord Max.cross-sectional area for remote signaling contact 1.5mm2 multi-strand cord / single cord
Status indicator normal:transparent / defect:red Status indicator normal:green / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

12 http://www.ahjinli.com http://www.ahjinli.com 13
Type II surge protective device Jinli Electric SPD Specialist Type II surge protective device

Reliable thermal tripping protection Reliable thermal tripping protection


Status indicator: transparent (normal), red (defect) Status indicator: transparent (normal), red (defect)
Max. discharge current: 80kA (8/20μs) Max. discharge current: 100kA (8/20μs)
Low voltage protection level Low voltage protection level
Fast response: action within nanosecond Fast response: action within nanosecond
Optional remote signaling Optional remote signaling

JLSP - GA 175/80/ / JLSP - GA 175/100/ /


Auxiliar y function(A:remote signaling;C:counter) Auxiliar y function(A:remote signaling;C:counter)
Protection mode (nP,nP+1,nP+N) Protection mode (nP,nP+1,nP+N)
Max. discharge current Imax Max. discharge current Imax
Max. continuous operating voltage Max. continuous operating voltage
AC series AC series
JLSP-GA175/80 JINLI surge protective device JLSP-GA175/100 JINLI surge protective device

54 81 108 62
27 27 27 27

45.5
90

90

90

90

COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC

Technical parameters Technical parameters


Model JLSP-GA175/80 Model JLSP-GA175/100
IEC Class Class Ⅱ IEC Class Class Ⅱ
AC network UN (50/60Hz)(V) 120 (TN-S) AC network UN (50/60Hz)(V) 120 (TN-S)
Max.continuous operating voltage Uc(V) 175 Max.continuous operating voltage Uc(V) 175
Nominal discharge current(8/20μs) In(kA) 40 Nominal discharge current(8/20μs) In(kA) 60
Max. discharge current(8/20μs) Imax(kA) 80 Max. discharge current(8/20μs) Imax(kA) 100
Voltage protection level Up(kV) ≤1.4 Voltage protection level Up(kV) ≤1.6
Max. backup fuse(A ) 100(gG) Max. backup fuse(A ) 125(gG)
Response time tA (ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature (℃) -40~+85 Operating temperature (℃) -40~+85
Relative humidity ≤95%(25℃) Relative humidity ≤95%(25℃)
Max.cross-sectional area 35mm2 multi-strand cord Max.cross-sectional area 35mm2 multi-strand cord
Certificates CE Certificates CE
Dimensions (1P) (mm) 27×90×62 Dimensions (1P) (mm) 36×90×65
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PA66 Housing material PA66
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:transparent / defect:red Status indicator normal:transparent / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

14 http://www.ahjinli.com http://www.ahjinli.com 15
Type II surge protective device Jinli Electric SPD Specialist Type II surge protective device

Reliable thermal tripping protection Reliable thermal tripping protection


Status indicator: green (normal), red (defect) Status indicator: transparent (normal), red (defect)
Max. discharge current: 40kA (8/20μs) Max. discharge current: 80kA (8/20μs)
Low voltage protection level Low voltage protection level
Fast response: action within nanosecond Fast response: action within nanosecond
Optional remote signaling Optional remote signaling
Pluggable design

JLSP - GA 275/40/ / JLSP - GA 275/80/ /


Auxiliar y function(A:remote signaling;C:counter) Auxiliar y function(A:remote signaling;C:counter)
Protection mode (nP,nP+1,nP+N) Protection mode (nP,nP+1,nP+N)
Max. discharge current Imax Max. discharge current Imax
Max. continuous operating voltage Max. continuous operating voltage
AC series AC series
JINLI surge protective device
JLSP-GA275/80 JINLI surge protective device
JLSP-GA275/40

54 81 108 62
27 27 27 27
36 54 72 62
18 18 18 18

45.5
90

90

90

90
45.5
90

90

90
90

COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC

COM NC NO COM NC NO COM NC NO COM NC NO

Technical parameters Technical parameters


Model JLSP-GA275/40 Model JLSP-GA275/80
IEC Class Class Ⅱ IEC Class Class Ⅱ
AC network UN (50/60Hz)(V) 202,230,102/208 (TN/TT/IT) AC network UN (50/60Hz)(V) 202,230V,102/208 (TN/TT/IT)
Max.continuous operating voltage Uc(V) 275 Max.continuous operating voltage Uc(V) 275
Nominal discharge current(8/20μs) In(kA) 20 Nominal discharge current(8/20μs) In(kA) 40
Max. discharge current(8/20μs) Imax(kA) 40 Max. discharge current(8/20μs) Imax(kA) 80
Voltage protection level Up(kV) ≤1.4 Voltage protection level Up(kV) ≤1.5
Max. backup fuse(A ) 100(gG) Max. backup fuse(A) 100(gG)
Response time tA (ns) ≤25 Response time tA(ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature (℃) -40 ~+85 Operating temperature (℃) -40~+85
Relative humidity ≤95%(25℃) Relative humidity ≤95%(25℃)
Max.cross-sectional area 35mm2 multi-strand cord Max.cross-sectional area 35mm2 multi-strand cord
Certificates CE Certificates CE
Dimensions (1P) (mm) 18×90×62 Dimensions (1P) (mm) 27×90×62
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PBT Housing material PA66
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:green / defect:red Status indicator normal:transparent / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

16 http://www.ahjinli.com http://www.ahjinli.com 17
Type II surge protective device Jinli Electric SPD Specialist Type II surge protective device

Reliable thermal tripping protection Reliable thermal tripping protection


Status indicator: transparent (normal),red (defect) Status indicator: green (normal), red (defect)
Max. discharge current: 100kA (8/20μs) Max. discharge current: 40kA (8/20μs)
Low voltage protection level Low voltage protection level
Fast response: action within nanosecond Fast response: action within nanosecond
Optional remote signaling Optional remote signaling
Pluggable design

JLSP - GA 275/100/ /
Auxiliar y function(A:remote signaling;C:counter) JLSP - GA 350/40/ /
Auxiliar y function(A:remote signaling;C:counter)
Protection mode (nP,nP+1,nP+N)
Protection mode (nP,nP+1,nP+N)
Max. discharge current Imax
Max. discharge current Imax
Max. continuous operating voltage
Max. continuous operating voltage
AC series
JLSP-GA275/100 JINLI surge protective device
AC series
JLSP-GA350/40 JINLI surge protective device

36 54 72 62
18 18 18 18

45.5
90

90

90
90
COM NC NO COM NC NO COM NC NO COM NC NO

Technical parameters Technical parameters


Model JLSP-GA275/100 Model JLSP-GA350/40
IEC Class Class Ⅱ IEC Class Class Ⅱ
AC network UN (50/60Hz)(V) 202,230,102/208 (TN/TT/IT) AC network UN (50/60Hz)(V) 230/400(TN/TT/IT)
Max.continuous operating voltage Uc(V) 275 Max.continuous operating voltage Uc(V) 350
Nominal discharge current(8/20μs) In(kA) 60 Nominal discharge current(8/20μs) In(kA) 20
Max. discharge current(8/20μs) Imax(kA) 100 Max. discharge current(8/20μs) Imax(kA) 40
Voltage protection level Up(kV) ≤1.8 Voltage protection level Up(kV) ≤1.7
Max. backup fuse(A) 125(gG) Max. backup fuse(A) 100(gG)
Response time tA(ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature (℃) -40~+85 Operating temperature (℃) -40~+85
Relative humidity ≤95%(25℃) Operating humidity ≤95%(25℃)
Max.cross-sectional area 35mm2 multi-strand cord Max.cross-sectional area of wire 35mm2 multi-strand cord
Certificates CE Certificates CE
Dimensions (1P) (mm) 36×90×65 Dimensions (1P) (mm) 18×90×62
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PA66 Housing material PBT
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 2
1.5mm multi-strand cord / single cord Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:transparent / defect:red Status indicator normal:green / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

18 http://www.ahjinli.com http://www.ahjinli.com 19
Type II surge protective device Jinli Electric SPD Specialist Type II surge protective device

Reliable thermal tripping protection Reliable thermal tripping protection


Status indicator: transparent (normal), red (defect) Status indicator: transparent (normal), red (defect)
Max. discharge current: 80kA (8/20μs) Max. discharge current: 100kA (8/20μs)
Low voltage protection level Low voltage protection level
Fast response: action within nanosecond Fast response: action within nanosecond
Optional remote signaling Optional remote signaling

JLSP - GA 350/80/ /
Auxiliar y function(A:remote signaling;C:counter) JLSP - GA 350/100/ /
Auxiliar y function(A:remote signaling;C:counter)
Protection mode (nP,nP+1,nP+N)
Protection mode (nP,nP+1,nP+N)
Max. discharge current Imax
Max. discharge current Imax
Max. continuous operating voltage
Max. continuous operating voltage
AC series
AC series
JLSP-GA350/80 JINLI surge protective device JLSP-GA350/100 JINLI surge protective device

54 81 108 62
27 27 27 27

45.5
90

90

90

90

COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC

Technical parameters Technical parameters


Model JLSP-GA350/80 Model JLSP-GA350/100
IEC Class Class Ⅱ IEC Class Class Ⅱ
AC network UN (50/60Hz)(V) 230/400(TN/TT/IT) AC network UN (50/60Hz)(V) 230/400(TN/TT/IT)
Max.continuous operating voltage Uc(V) 350 Max.continuous operating voltage Uc(V) 350
Nominal discharge current(8/20μs) In(kA) 40 Nominal discharge current(8/20μs) In(kA) 60
Max. discharge current(8/20μs) Imax(kA) 80 Max. discharge current(8/20μs) Imax(kA) 100
Voltage protection level Up(kV) ≤2.0 Voltage protection level Up(kV) ≤2.3
Max. backup fuse(A) 100(gG) Max. backup fuse(A) 125(gG)
Response time tA (ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature (℃) -40~+85 Operating temperature (℃) -40~+85
Operating humidity ≤95%(25℃) Operating humidity ≤95%(25℃)
Max.cross-sectional area of wire 35mm2 multi-strand cord Max.cross-sectional area of wire 35mm2 multi-strand cord
Certificates CE Certificates CE
Dimensions (1P) (mm) 27×90×62 Dimensions (1P) (mm) 36×90×65
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PA66 Housing material PA66
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:transparent / defect:red Status indicator normal:transparent / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

20 http://www.ahjinli.com http://www.ahjinli.com 21
Type II surge protective device Jinli Electric SPD Specialist Type II surge protective device

Reliable thermal tripping protection


Status indicator: green (normal), red (defect) Reliable thermal tripping protection
Max. discharge current: 40kA (8/20μs) Status indicator: transparent (normal), red(defect)
Low voltage protection level Max. discharge current: 80kA (8/20μs)
Fast response: action within nanosecond Low voltage protection level
Optional remote signaling Fast response: action within nanosecond
Pluggable design Optional remote signaling

JLSP - 385/40/ / JLSP - 385/80/ /


Auxiliar y function(A:remote signaling;C:counter) Auxiliar y function(A:remote signaling;C:counter)
Protection mode (nP,nP+1,nP+N) Protection mode (nP,nP+1,nP+N)
Max. discharge current Imax Max. discharge current Imax
Max. continuous operating voltage Max. continuous operating voltage
JLSP-385/40 JINLI surge protective device JLSP-385/80 JINLI surge protective device

36 54 72 62 54 81 108 62
18 18 18 18 27 27 27 27

45.5
45.5

90

90

90

90
90

90

90
90

COM NC NO COM NC NO COM NC NO COM NC NO COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC

Technical parameters Technical parameters


Model JLSP-385/40 Model JLSP-385/80
IEC Class Class Ⅱ IEC Class Class Ⅱ
AC network UN (50/60Hz)(V) 230/400,240/415 (TN/TT/IT) AC network UN (50/60Hz)(V) 230/400,240/415 (TN/TT/IT)
Max.continuous operating voltage Uc(V) 385 Max.continuous operating voltage Uc(V) 385
Nominal discharge current(8/20μs) In(kA) 20 Nominal discharge current(8/20μs) In(kA) 40
Max. discharge current(8/20μs) Imax(kA) 40 Max. discharge current(8/20μs) Imax(kA) 80
Voltage protection level Up(kV) ≤1.8 Voltage protection level Up(kV) ≤2.1
Max. backup fuse(A) 100(gG) Max. backup fuse(A) 100(gG)
Response time tA (ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature (℃) -40~+85 Operating temperature (℃) -40~+85
Relative humidity ≤95%(25℃) Relative humidity ≤95%(25℃)
Max.cross-sectional area 35mm2 multi-strand cord Max.cross-sectional area 35mm2 multi-strand cord
Certificates CE、UL Certificates CE
Dimensions (1P) (mm) 18×90×62 Dimensions (1P) (mm) 27×90×62
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PBT Housing material PA66
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:green / defect:red Status indicator normal:transparent / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

22 http://www.ahjinli.com http://www.ahjinli.com 23
Type II surge protective device Jinli Electric SPD Specialist Type II surge protective device

Reliable thermal tripping protection Reliable thermal tripping protection


Status indicator: transparent (normal), red (defect) Status indicator: green (normal), red (defect)
Max. discharge current: 100kA (8/20μs) Max. discharge current: 40kA (8/20μs)
Low voltage protection level Low voltage protection level
Fast response: action within nanosecond Fast response: action within nanosecond
Optional remote signaling Optional remote signaling
Pluggable design

JLSP - 385/100/ /
Auxiliar y function(A:remote signaling;C:counter)
Protection mode (nP,nP+1,nP+N) JLSP - GA 440 /40/ /
Max. discharge current Imax Auxiliar y function(A:remote signaling;C:counter)
Max. continuous operating voltage Protection mode (nP,nP+1,nP+N)
Max. discharge current Imax
JLSP-385/100 JINLI surge protective device
Max. continuous operating voltage
AC series
JLSP-GA440/40 JINLI surge protective device

36 54 72 62
18 18 18 18

45.5
90

90

90
90
COM NC NO COM NC NO COM NC NO COM NC NO

Technical parameters Technical parameters


Model JLSP-385/100 Model JLSP-GA440/40
IEC Class Class Ⅱ IEC Class Class Ⅱ
AC network UN (50/60Hz)(V) 230/400,240/415 (TN/TT/IT) AC network UN (50/60Hz)(V) 230/400,240/415 (TN/TT/IT)
Max.continuous operating voltage Uc(V) 385 Max. continuous operating voltage Uc(V) 440
Nominal discharge current(8/20μs) In(kA) 60 Nominal discharge current(8/20μs) In(kA) 20
Max. discharge current(8/20μs) Imax(kA) 100 Max. discharge current(8/20μs) Imax(kA) 40
Voltage protection level Up(kV) ≤2.5 Voltage protection level Up(kV) ≤2.2
Max. backup fuse(A) 125(gG) Max. backup fuse(A) 100(gG)
Response time tA (ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature (℃) -40~+85 Operating temperature (℃) -40 ~+85
Relative humidity ≤95%(25℃) Relative humidity ≤95%(25℃)
Max.cross-sectional area 35mm2 multi-strand cord Max. cross-sectional area of wire 35mm2 multi-strand cord
Certificates CE Certificates CE
Dimensions (1P) (mm) 36 ×90×65 Dimensions (1P) (mm) 18×90×62
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PA66 Housing material PBT
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Max. cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:transparent / defect:red Status indicator normal:green / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

24 http://www.ahjinli.com http://www.ahjinli.com 25
Type II surge protective device Jinli Electric SPD Specialist Type II surge protective device

Reliable thermal tripping protection Reliable thermal tripping protection


Status indicator: transparent (normal), red (defect) Status indicator: transparent (normal), red (defect)
Max. discharge current: 80kA (8/20μs) Max. discharge current: 100kA (8/20μs)
Low voltage protection level Low voltage protection level
Fast response: action within nanosecond Fast response: action within nanosecond
Optional remote signaling Optional remote signaling

JLSP - GA 440 /80/ / JLSP - GA 440/100/ /


Auxiliar y function(A:remote signaling;C:counter) Auxiliar y function(A:remote signaling;C:counter)
Protection mode (nP,nP+1,nP+N) Protection mode (nP,nP+1,nP+N)
Max. discharge current Imax Max. discharge current Imax
Max. continuous operating voltage Max. continuous operating voltage
AC series AC series
JLSP-GA440/80 JINLI surge protective device
JLSP-GA440/100 JINLI surge protective device

54 81 108 62
27 27 27 27

45.5
90

90

90

90

COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC

Technical parameters Technical parameters


Model JLSP-GA440/80 Model JLSP-GA440/100
IEC Class Class Ⅱ IEC Class Class Ⅱ
AC network UN (50/60Hz)(V) 230/400,240/415 (TN/TT/IT) AC network UN (50/60Hz)(V) 230/400,240/415 (TN/TT/IT)
Max. continuous operating voltage Uc(V) 440 Max. continuous operating voltage Uc(V) 440
Nominal discharge current(8/20μs) In(kA) 40 Nominal discharge current(8/20μs) In(kA) 60
Max. discharge current(8/20μs) Imax(kA) 80 Max. discharge current(8/20μs) Imax(kA) 100
Voltage protection level Up(kV) ≤2.3 Voltage protection level Up(kV) ≤2.5
Max. backup fuse(A) 100(gG) Max. backup fuse(A) 125(gG)
Response time tA (ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature (℃) -40~+85 Operating temperature (℃) -40~+85
Relative humidity ≤95%(25℃) Relative humidity ≤95%(25℃)
Max. cross-sectional area of wire 35mm2 multi-strand cord Max. cross-sectional area of wire 35mm2 multi-strand cord
Certificates CE Certificates CE
Dimensions (1P) (mm) 27×90×62 Dimensions (1P) (mm) 36×90×65
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PA66 Housing material PA66
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max. cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Max. cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:transparent / defect:red Status indicator normal:transparent / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

26 http://www.ahjinli.com http://www.ahjinli.com 27
Type II surge protective device Jinli Electric SPD Specialist Type II surge protective device

Reliable thermal tripping protection


Reliable thermal tripping protection Status indicator: transparent (normal), red (defect)
Status indicator: green (normal), red (defect) Max. discharge current: 80kA (8/20μs)
Max. discharge current: 40kA (8/20μs) Low voltage protection level
Low voltage protection level Fast response: action within nanosecond
Fast response: action within nanosecond Optional remote signaling
Optional remote signaling
Pluggable design

JLSP - GA 485/40/ /
Auxiliar y function(A:remote signaling;C:counter)
JLSP - GA 485/40/ / Protection mode (nP,nP+1,nP+N)
Auxiliar y function(A:remote signaling;C:counter) Max. discharge current Imax
Protection mode (nP,nP+1,nP+N) Max. continuous operating voltage
Max. discharge current Imax AC series
Max. continuous operating voltage JINLI surge protective device
AC series
JLSP-GA485/80
JLSP-GA485/40 JINLI surge protective device

54 81 108 62
36 54 72 62 27 27 27 27
18 18 18 18

45.5
90

90

90

90
45.5
90

90

90
90

COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC

COM NC NO COM NC NO COM NC NO COM NC NO

Technical parameters Technical parameters


Model JLSP-GA485/40 Model JLSP-GA485/80
IEC Class Class Ⅱ IEC Class Class Ⅱ
AC network UN (50/60Hz)(V) 460,277/480 (TN/TT/IT) AC network UN (50/60Hz)(V) 460,277/480 (TN/TT/IT)
Max. continuous operating voltage Uc(V) 485 Max. continuous operating voltage Uc(V) 485
Nominal discharge current(8/20μs) In(kA) 20 Nominal discharge current(8/20μs) In(kA) 40
Max. discharge current(8/20μs) Imax(kA) 40 Max. discharge current(8/20μs) Imax(kA) 80
Voltage protection level Up(kV) ≤2.2 Voltage protection level Up(kV) ≤2.4
Max. backup fuse(A) 100(gG) Max. backup fuse(A) 100(gG)
Response time tA (ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature (℃) -40~+85 Operating temperature (℃) -40~+85
Relative humidity ≤95%(25℃) Relative humidity ≤95%(25℃)
Max. cross-sectional area 35mm2multi-strand cord Max. cross-sectional area 35mm2multi-strand cord
Certificates CE Certificates CE
Dimensions (1P) (mm) 18×90×62 Dimensions (1P) (mm) 27×90×62
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PBT Housing material PA66
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max. cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Max. cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:green / defect:red Status indicator normal:transparent / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

28 http://www.ahjinli.com http://www.ahjinli.com 29
Type II surge protective device Jinli Electric SPD Specialist Type II surge protective device

Reliable thermal tripping protection Reliable thermal tripping protection


Status indicator: transparent (normal), red (defect) Status indicator: green (normal), red (defect)
Max. discharge current: 100kA (8/20μs) Max. discharge current: 40kA (8/20μs)
Low voltage protection level Low voltage protection level
Fast response: action within nanosecond Fast response: action within nanosecond
Optional remote signaling Optional remote signaling
Pluggable design
Apply to industrial field, PV system and wind turbine system

JLSP - GA 485/100/ /
Auxiliar y function(A:remote signaling;C:counter)
Protection mode (nP,nP+1,nP+N) JLSP - GA 750/40/ /
Max. discharge current Imax Auxiliar y function(A:remote signaling;C:counter)
Max. continuous operating voltage Protection mode (nP,nP+1,nP+N)
AC series Max. discharge current Imax
JINLI surge protective device Max. continuous operating voltage
JLSP-GA485/100 AC series
JINLI surge protective device
JLSP-GA750/40

36 54 72 62
18 18 18 18

45.5
90

90

90
90
COM NC NO COM NC NO COM NC NO COM NC NO

Technical parameters Technical parameters


Model JLSP-GA485/100 Model JLSP-GA750/40
IEC Class Class Ⅱ IEC Class Class Ⅱ
AC network UN (50/60Hz)(V) 460,277/480 (TN/TT/IT) AC network UN (50/60Hz)(V) 690,400/690 (TN/TT/IT)
Max. continuous operating voltage Uc(V) 485 Max.continuous operating voltage Uc(V) 750
Nominal discharge current(8/20μs) In(kA) 60 Nominal discharge current(8/20μs) In(kA) 20
Max. discharge current(8/20μs) Imax(kA) 100 Max. discharge current(8/20μs) Imax(kA) 40
Voltage protection level Up(kV) ≤2.7 Voltage protection level Up(kV) ≤2.8
Max. backup fuse(A) 125(gG) Max. backup fuse(A) 100(gG)
Response time tA(ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature (℃) -40~+85 Operating temperature (℃) -40~+85
Relative humidity ≤95%(25℃) Operating humidity ≤95%(25℃)
Max. cross-sectional area 35mm2multi-strand cord Max.cross-sectional area 35mm2multi-strand cord
Certificates CE Certificates CE、UL
Dimensions (1P) (mm) 36×90×65 Dimensions (1P) (mm) 18×90×62
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PA66 Housing material PBT
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:transparent / defect:red Status indicator normal:green / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

30 http://www.ahjinli.com http://www.ahjinli.com 31
Type II surge protective device Jinli Electric SPD Specialist Type II surge protective device

Reliable thermal tripping protection Reliable thermal tripping protection


Status indicator: transparent (normal), red (defect) Status indicator: transparent (normal), red (defect)
Max. discharge current: 80kA (8/20μs) Max. discharge current: 100kA (8/20μs)
Low voltage protection level
Low voltage protection level
Fast response: action within nanosecond
Optional remote signaling
Fast response: action within nanosecond
Optional remote signaling
Apply to industrial field, PV system and wind turbine system

JLSP - GA 750/80/ /
Auxiliar y function(A:remote signaling;C:counter)
JLSP - GA 750/100/ /
Protection mode (nP,nP+1,nP+N) Auxiliar y function(A:remote signaling;C:counter)
Max. discharge current Imax Protection mode (nP,nP+1,nP+N)
Max. continuous operating voltage Max. discharge current Imax
AC series Max. continuous operating voltage
JLSP-GA750/80 JINLI surge protective device JLSP-GA750/100 AC series
JINLI surge protective device

54 81 108 62
27 27 27 27

45.5
90

90

90

90

COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC COM NC

Technical parameters Technical parameters


Model JLSP-GA750/80 Model JLSP-GA750/100
IEC Class Class Ⅱ IEC Class Class Ⅱ
AC network UN (50/60Hz)(V) 690,400/690 (TN/TT/IT) AC network UN (50/60Hz)(V) 690,400/690 (TN/TT/IT)
Max.continuous operating voltage Uc(V) 750 Max.continuous operating voltage Uc(V) 750
Nominal discharge current(8/20μs) In(kA) 40 Nominal discharge current(8/20μs) In(kA) 60
Max. discharge current(8/20μs) Imax(kA) 80 Max. discharge current(8/20μs) Imax(kA) 100
Voltage protection level Up(kV) ≤3.2 Voltage protection level Up(kV) ≤3.7
Max. backup fuse(A) 100(gG) Max. backup fuse(A) 125(gG)
Response time tA (ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (kA) 25 Capacity of withstand short circuit (kA) 25
Operating temperature(℃) -40~+85 Operating temperature (℃) -40~+85
Operating humidity ≤95%(25℃) Operating humidity ≤95%(25℃)
Max.cross-sectional area 35mm2multi-strand cord Max.cross-sectional area 35mm2multi-strand cord
Certificates CE Certificates CE
Dimensions (1P) (mm) 27×90×62 Dimensions (1P) (mm) 36×90×65
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PA66 Housing material PA66
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:transparent / defect:red Status indicator normal:transparent / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

32 http://www.ahjinli.com http://www.ahjinli.com 33
DC type surge protective device Jinli Electric SPD Specialist DC type surge protective device

Reliable thermal tripping protection Reliable thermal tripping protection


Status indicator: green (normal), red (defect) Status indicator: green (normal), red (defect)
Max. discharge current: 40kA (8/20μs) Max. discharge current: 40kA (8/20μs)
Low voltage protection level Low voltage protection level
Fast response: action within nanosecond Fast response: action within nanosecond
Optional remote signaling Optional remote signaling
Pluggable design Pluggable design
Apply to DC 24V~48V system Apply to DC 110V system

JLSP - DC 85/40/ / JLSP - DC 225/40/ /


Auxiliar y function(A:remote signaling;C:counter) Auxiliar y function(A:remote signaling;C:counter)
Protection mode (nP,nP+1,nP+N) Protection mode (nP,nP+1,nP+N)
Max. discharge current Imax Max. discharge current Imax
Max. continuous operating voltage Max. continuous operating voltage
DC series DC series
JINLI surge protective device JINLI surge protective device
JLSP-DC85/40 JLSP-DC225/40

36 62
36 54 62
54
18 18 18 18 18 18

45.5

45.5
90

90

90

90
90

90
COM NC NO COM NC NO COM NC NO
COM NC NO COM NC NO COM NC NO

Technical parameters Technical parameters


Model JLSP-DC85/40 Model JLSP-DC225/40
IEC Class Class Ⅱ IEC Class Class Ⅱ
DC network UN (V) 24,48 DC network UN (50/60Hz)(V) 110
Max.continuous operating voltage Uc(V) 85 Max.continuous operating voltage Uc(V) 225
Nominal discharge current In(kA) 20 Nominal discharge current In(kA) 20
Max. discharge current(8/20μs) Imax(kA) 40 Max. discharge current(8/20us) Imax(kA) 40
Voltage protection level Up(kV) ≤0.8 Voltage protection level Up(kV) ≤1.2
Max. backup fuse ( A ) 35A DC(gG) Max. backup fuse(A) 35A DC(gG)
Response time tA (ns) ≤25 Response time tA (ns) ≤25
Capacity of withstand short circuit (A) 300 Capacity of withstand short circuit (A ) 300
Operating temperature (℃) -40~+85 Operating temperature (℃) -40~+85
Relative humidity ≤95%(25℃) Relative humidity ≤95%(25℃)
Max.cross-sectional area 35mm2multi-strand cord Max.cross-sectional area 35mm2multi-strand cord
Certificates CE Certificates CE
Dimensions (1P) (mm) 18×90×62 Dimensions (1P)(mm) 18×90 ×62
Mounting DIN Rail 35mm Mounting DIN Rail 35mm
Protection rating IP 20 Protection rating IP 20
Housing material PBT Housing material PBT
Flame retardant rating UL94 V-0 Flame retardant rating UL94 V-0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:green / defect:red Status indicator normal:green / defect:red
Standards compliance IEC61643-11、GB/T 18802.11 Standards compliance IEC61643-11、GB/T 18802.11

34 http://www.ahjinli.com http://www.ahjinli.com 35
DC type surge protective device Jinli Electric SPD Specialist Photovoltaic surge protective device

Photovoltaic surge protective device is available for 1000V and 1500V DC power system of photovoltaic power
Reliable thermal tripping protection
generation equipment in DC side, DC combiner box, inverter in DC side, etc.
Status indicator: green (normal), red (defect)
Max. discharge current: 40kA (8/20μs)
Low voltage protection level Reliable thermal tripping protection
Fast response: action within nanosecond Status indicator: green (normal), red (defect)
Optional remote signaling Max. discharge current: 40kA (8/20μs)
Pluggable design
Apply to DC 220V system Fast response: action within nanosecond
Optional remote signaling
Pluggable design
Apply to PV system: DC 1100V

JLSP - DC 350/40/ /
Auxiliar y function(A:remote signaling;C:counter)
Protection mode (nP,nP+1,nP+N)
Max. discharge current Imax
JLSP - GD 1000/40/ /
Max. continuous operating voltage Auxiliar y function(A:remote signaling;C:counter)
DC series
Protection mode
JINLI surge protective device
Max. discharge current Imax
JLSP-DC350/40 Nominal voltage
PV series SPD for DC network
JINLI surge protective device

36
JLSP-GD1000/40
54 62
18 18 18

36 54 62
18 18 18

45.5
90

90
90

45.5
90

90
90
COM NC NO COM NC NO COM NC NO

COM NC NO COM NC NO COM NC NO

Technical parameters
Model JLSP-DC350/40
Technical parameters
IEC Class Class Ⅱ Model JLSP-GD1000/40
DC network UN (V) 220 IEC Class Class Ⅱ
Max.continuous operating voltage Uc(V) 350 DC network UN (Vdc) 1000, 1100
Nominal discharge current In(kA) 20 Max.continuous operating voltage Uc 1200
Max. discharge current(8/20μs) Imax(kA) 40 Nominal discharge current In(kA) 20
Voltage protection level Up(kV) ≤1.4 Max. discharge current (8/20μs) Imax(kA) 40
Max. backup fuse(A) 35A DC(gG) Voltage protection level Up(kV) ≤4.0
Response time tA (ns) ≤25 Max. backup fuse(A ) 100A DC(gG)
Capacity of withstand short circuit (A ) 300 Response time tA(ns) ≤25
Operating temperature (℃) -40 ~+85 Capacity of withstand short circuit (A) 1000
Relative humidity ≤95%(25℃) Operating temperature (℃) -40~+85
Max.cross-sectional area 35mm2multi-strand cord Relative humidity ≤95%(25℃)
Certificates CE Max.cross-sectional area of wire 35mm2 multi-strand cord
Dimensions (1P) (mm) 18×90×62 Certificates CE
Mounting DIN Rail 35mm Dimensions (1P) (mm) 18×90×62
Protection rating IP 20 Mounting DIN Rail 35mm
Housing material PBT Protection rating IP 20
Flame retardant rating UL94 V-0 Housing material PBT
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A Flame retardant rating UL94V -0
Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Status indicator normal:green / defect:red Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Standards compliance IEC61643-11、GB/T 18802.11 Status indicator normal:green / defect:red
Standards compliance IEC61643-31、GB/T 18802.31

36 http://www.ahjinli.com http://www.ahjinli.com 37
Photovoltaic surge protective device Jinli Electric SPD Specialist PCB type surge protective device

Reliable thermal tripping protection


Status indicator: green (normal), red (defect)
Max. discharge current: 40kA (8/20μs)
Low voltage protection level Surge protective device soldered directly onto PCB is voltage-limiting type SPD and mainly
Fast response: action within nanosecond
Optional remote signaling
used to prevent surge overvoltage in AC/DC power supply circuit, which equipped with safety
Pluggable design disconnection device and status indicator. Normally, the indicator window is green, and will turn
Apply to PV system: ≤ DC 1500V
to red under malfunction and generate remote alarm signaling(Normal closed electrical
independent contacts)
It is applicable to 220V/380V AC power system or 670V (<670V) DC system. In is 10kA and Imax
JLSP - GD 1500/40/ /
Auxiliar y function(A:remote signaling;C:counter) is 20kA. It can increase nominal discharge current by parallel connections. Different protection
Protection mode
Max. discharge current Imax modes are available according to the requirements of customers. Surge protective device is
Nominal voltage
PV series SPD for DC network
soldered directly onto PCB of various electrical and electronic equipment, such as AC circuit of
JINLI surge protective device
charging pile, inverter, communication equipment, household appliances etc. as the second or
JLSP-GD1500/40 third stage protection.

36 54 62
18 18 18

45.5
90

90
90

COM NC NO COM NC NO COM NC NO

Technical parameters
Model JLSP-GD1500/40
IEC Class Class Ⅱ
DC network UN (Vdc) 1500
Max.continuous operating voltage Uc(V) 1800
Nominal discharge current In(kA) 20
Max. discharge current (8/20μs) Imax(kA) 40
Voltage protection level Up(kV) ≤ 6.0
Max. backup fuse(A) 100A DC(gG)
Response time tA (ns) ≤25
Capacity of withstand short circuit (A) 1000
Operating temperature (℃) -40~+85
Relative humidity ≤95%(25℃)
Max.cross-sectional area of wire 35mm2 multi-strand cord
Certificates CE
Dimensions (1P) (mm) 18×90×62
Mounting DIN Rail 35mm
Protection rating IP 20
Housing material PBT
Flame retardant rating UL94V -0
Capacity of remote signaling contact 250VAC/0.5A 30VDC/3A
Max.cross-sectional area for remote signaling contact 1.5mm2multi-strand cord / single cord
Status indicator normal:green / defect:red
Standards compliance IEC61643-31、GB/T 18802.31

38 http://www.ahjinli.com http://www.ahjinli.com 39
PCB type surge protective device Jinli Electric SPD Specialist PCB type surge protective device

AC series DC series
Reliable thermal tripping protection Reliable thermal tripping protection
Low voltage protection level Low voltage protection level
Status indicator Status indicator
Optional remote signaling Optional remote signaling
Free combination for protection mode Free combination for protection mode
Easy for automatic soldered Easy for automatic soldered
Apply to protection for inverter ,charge pile, etc. Apply to protection for inverter ,charge pile, etc.

GTSP - M AV / /A GTSP - M DV / /A
Remote signaling function (optional) Remote signaling function (optional)
Max. discharge current Max. discharge current
Max. continuous operating voltage Max. continuous operating voltage
AC single MOV DC single MOV
GTSP-MAV Mechanical tripping GTSP-MDV Mechanical tripping
JINLI surge protective device JINLI surge protective device

34.6±0.2
34.6±0.2
27.4±0.2
31.4±0.2

27.4±0.2
31.4±0.2

14±0.2
14±0.2
4

2*0.2 0.8

4
3.8±0.3 2*0.2
3.4
2*0.4 3.8±0.3 0.8
30±0.5 5 2*0.4 3.4
30±0.5
5

Technical parameters Technical parameters


Model GTSP-MDV500/20/A GTSP-MDV670/20/A GTSP-MDV890/20/A
IEC Class Class Ⅱ
UL level Type 4
Max.continuous operating voltage of PV system Ucpv(V) 500 670 890
Nominal discharge current(8/20μs) In(kA) 10
Max. discharge current(8/20μs) Imax(kA) 20
Voltage protection level Up(kV) 1.6 2. 0 2.7
Iscpv Capacity of withstand short circuit(A)Iscpv 20A/750Vdc 20A/1000Vd c 20A/1500Vdc
Remote signaling NC (Optional)
Capacity of remote signaling contact AC 250V/2A、DC 50V/0.5A
Flame retardant rating UL94 V-0
temperature:-40℃~85℃;relative humidity:95%(25℃)
Operating temperature& humidity temperature:-40℃~85℃;relative humidity:95%(25℃)
Protection rating IP20
(m)
(kPa)
Altitude (m) ≤4000
Air pressure (kPa) 70~106
Housing material PBT
Certificates CE、RoHS Housing color Red(Normal)
(not including the pin) Certificates CE、RoHS
soldered onto PCB Dimensions(mm) 34.9*14.2*27.4(not including the pin)
normal:green / defect:red
Mounting soldered onto PCB
Status indicator normal:green / defect:red

40 http://www.ahjinli.com http://www.ahjinli.com 41
Integrated PCB type surge protective device Jinli Electric SPD Specialist Integrated PCB type surge protective device

Reliable thermal tripping protection


Low voltage protection level
Status indicator
Integrated surge protective device soldered onto PCB is voltage-limiting type SPD and mainly Optional remote signaling
Integrated full mode protection
used to prevent surge overvoltage in AC power system, performance of surge protective device is Easy for automatic soldered
Apply to protection for inverter ,charge pile, etc.
stable with common mode protection and reliable tripping device. Remote signaling function is Full-mode protection
optional according to the customer requirement (Normal closed electrical independent
contact). In=10kA and Imax=20kA. It is applicable for 220/380V AC system. Integrated surge GTSP - T F / /A
protective device is soldered directly onto PCB of various electrical and electronic equipment, Remote signaling function (optional)
Max. discharge current
such as AC circuit of charging pile, inverter, communication equipment, household appliances Max. continuous operating voltage
Full-mode protection
etc. as the second or third stage protection. Temperature tripping

GTSP-TF JINLI surge protective device

34.9±0.3

14.2±0.2
27.4±0.2
+0.2
0
2*0.2

4
3.8±0.3 0.8
2*0.4 3.4 5
30±0.5

Technical parameters

Model GTSP-TF275/20 GTSP-TF320/20 GTSP-TF350/20 GTSP-TF385/20


Max. continuous operating voltage Uc(Vac) 275 320 350 385
Nominal discharge current In(8/20μs(kA) 10 10 10 10
Max.discharge current Imax(8/20μs)
(kA) 20 20 20 20
Voltage protection level Up(L/N-PE)(kV) 1.3 1.5 1.6 1.7
Voltage protection level Up(L-N)(kV) 1.7 1.7 1.7 1.7
IEC Class Class Ⅱ
UL level Type 4
Remote signaling Normal close
Remote signaling contact AC 250V/2A DC 50V/0.5A
Flame retardant rating of housing UL94 V-0
Operating environment Temperature:-40℃~85℃; Relative humidity:95%(25℃)
Protection rating IP20
Altitude (m) ≤4000
Air pressure(kPa) 70-106
Housing material PBT
Housing color Black (Normal)
Certificates CE、RoHS
51.2*25.2*35 (not including the pin);
Dimensions(mm)
51.2*25.2*40.5 ( including the pin)
Mounting soldered directly onto PCB
Standards compliance IEC61643-11,GB/T18802.11

42 http://www.ahjinli.com http://www.ahjinli.com 43
Integrated PCB type surge protective device Jinli Electric SPD Specialist Signal surge protective device

Reliable thermal tripping protection


Low voltage protection level
Status indicator Jinli signal surge protective devices are based on reliable multistage protection design that combines a high
Optional remote signaling discharge current capacity and low residual voltage with fast response time. Different protection stages are fully
Integrated full mode protection
coordinated with one another to ensure the reliability of protectors, otherwise the protection stages will not reliably
Easy for automatic soldered
Apply to protection for inverter ,charge pile, etc and cause faults in the protective devices.
Common-mode protection Signal surge protective device is used in weak current control systems (industrial control systems,
telecommunication systems, fire alarm systems, security monitoring systems etc.). To ensure the telecom or data
equipment sufficiently reliable, the signal surge protective device must be installed to protect data equipment from
transient overvoltage.
GTSP - T C / /A Antenna systems, especially exposed to lightning phenomena, are particularly sensitive to surge voltage, Jinli
Remote signaling function (optional)
Max. discharge current
coaxial SPD compliance with EMC is recommended to install to comply to different operation requirements. Excellent
Max. continuous operating voltage shielding is important for data transmission. Jinli SPD with metal housing can provide good shielding and is widely
Common-mode protection used in harsh industrial environments with no attenuation, and different connections are available.
GTSP-TC Temperature tripping
JINLI surge protective device

34.9±0.3

14.2±0.2
27.4±0.2
+0.2
0

2*0.2
4

3.8±0.3 0.8
2*0.4 3.4 5
30±0.5

Technical parameters
Model GTSP-TC275/20 GTSP-TC320/20 GTSP-TC350/20 GTSP-TC385/20

Max. continuous operating voltage Uc (V) 275 320 350 385

Nominal discharge current In(8/20μs)


(kA) 10 10 10 10

Max. discharge current(8/20μs)(kA) 20 20 20 20

Voltage protection level (L/N-PE) (kV) 1.3 1.5 1.6 1.7

Voltage protection level Up (L-N) (kV) 2.2 2.7 2.9 3. 0

IEC class Class Ⅱ

UL level Type 4

Remote signaling Normal close

Remote signaling contact AC 250V/2A DC 50V/0.5A

Flame retardant rating of housing UL94 V-0

Operating environment Temperature:-40℃~85℃;Relative humidity:95%(25℃)

Protection rating IP20

Altitude (m) ≤4000

Air pressure (kPa) 70-106

Housing material PBT

Housing color Black(Normal)

Certificates CE、RoHS
51.2*25.2*35(not including the pin);
Dimensions(mm)
51.2*25.2*40.5 ( including the pin)
Mounting soldered directly onto PCB

Standards compliance IEC61643-11,GB/T 18802.11

44 http://www.ahjinli.com http://www.ahjinli.com 45
Signal surge protective device Jinli Electric SPD Specialist Signal surge protective device

Data line surge protective device ( Terminal block series) DB9 series
Terminal block series Low insertion loss and low voltage protection level
Fast response: action within nanosecond
JLSP-DB9FM High rate transmission
Low insertion loss and low voltage protection level Large discharge current capacity
Fast response: action within nanosecond DB9 interface, easy mounting
High rate transmission Protection for data line with D-SUB interface
Large discharge current capacity
DIN rail 35mm mounting
Protection for 2 signal data lines
JLSP-DP2C

63 17
JLSP - D P 2 C
Nominal voltage
Connector JLSP - D B9 F M
No. of interface Nominal voltage

34
Housing material:plastic Output:Male
Data line surge protective device Input:Female
JINLI surge protective device B9 connection
Data line surge protective device
JINLI surge protective device

Technical parameters PE
Technical parameters
Nominal
Max.continuous discharge Protection level Protection level
Nominal Frequency Impedance Insertion loss
Model operating current Up(line-line) Up(line-PE)(V)
voltage Un(V) (8/20μs)In (MHz) (Ω) (dB)
voltage Uc(Vdc) (V)(B2:4kV) (B2:4kV)
(kA)

JLSP-DB9FM5 5 8
JLSP-DB9FM15 15 18 5 ≤40 ≤600 10 - ≤0.3
JLSP-DB9FM24 24 30

Low insertion loss and low voltage Protection level


Surge protective device for video data transmission
Fast response: action within nanosecond 12.4 70
High rate transmission
Large discharge current capacity
Low insertion loss and low voltage protection level
DIN rail 35mm mounting
Fast response: action within nanosecond
Direct grounding by rail
High rate transmission
Pluggable design and easy for replacement
Large discharge current capacity
Protection for 3/4 signal data lines
DB9 interface, easy mounting
90.1

Protection for data line with D-SUB interface

JLSP-VABFM5
JLSP-DO4C

JLSP - D O 4 C
Nominal voltage 84 25
Connector
JLSP - V A B F M 5
No. of interface Nominal voltage
Housing material:pluggable plastic Output:Male

25
Data line surge protective device Input:Female
JINLI surge protective device Interface type: BNC
Housing material:aluminum
Video data series
JINLI surge protective device

Technical parameters PE

Model
Nominal voltage
Max.continuous
operating
Nominal
discharge
Protection level Protection level
Up(line-line) Up(line-PE)
Frequency Impedance
Insertion
Loss
Technical parameters
Un(V) current(8/20μ (MHz) (Ω)
voltage Uc(Vdc) s)In(kA) (V)(B2:4kV) (V) (B2:4kV) (dB)
Nominal
Max.continuous discharge Protection level Protection level
JLSP-DO4C5 5 8 ≤30 Nominal voltage Frequency Impedance Insertion
Model operating current Up(line-shield) Up(line-PE)(V)
Un(V) (8/20μs)In (MHz) (Ω) loss(dB)
JLSP-DO4C15 15 18 5 ≤40 ≤600 10 ≤3 ≤0.3 voltage Uc(Vdc) (V)(B2:4kV) (B2:4kV)
(kA)
JLSP-DO4C24 24 30 ≤60
JLSP-VABFM5 5 8 5 ≤30 ≤600 10 50 ≤0.3

46 http://www.ahjinli.com http://www.ahjinli.com 47
Signal surge protective device Jinli Electric SPD Specialist Signal surge protective device

Multi-function surge protective device for video survey camera

Low insertion loss and low voltage protection level Low insertion loss and low voltage protection level
Fast response: action within nanosecond Fast response: action within nanosecond
High rate transmission High rate transmission
Large discharge current capacity Large discharge current capacity
RJ45 connection BNC connection
Power and video in single unit Power and video in single unit

JLSP-MA2E JLSP-MA2BFM

JLSP - M A 2 B FM
Nominal voltage
A: AC Power, D: DC Power
JLSP - M A 2 E Input/output:Female/Male
Nominal voltage
Interface type: BNC
A: AC Power, D: DC Power
Function 2: AC and video in single unit
Interface type: RJ45
Housing material: aluminum
Function 2: AC and video in single unit
Multi-function SPD
Housing material: aluminum
JINLI surge protective device
Multi-function SPD
JINLI surge protective device

Technical parameters Technical parameters

Max. Nominal Protection Protection Max. Nominal Protection Protection


Nominal continuous discharge level Up level Up Nominal continuous discharge level Up level Up
Max. data Impedance Insertion Max. data Impedance Insertion
Model Function Application voltage operating current (line-line) (line-PE) Connecton Model Function Application voltage operating current (line-line) (line-PE) Connecton
rate (Mbps) (Ω) loss (dB) rate (Mbps) (Ω) loss (dB)
Un(V) voltage (8/20μs) (V) (V) Un(V) voltage (8/20μs) (V) (V)
Uc(Vdc) In(kA) (B2:4kV) (B2:4kV) Uc(Vdc) In(kA) (B2:4kV) (B2:4kV)

JLSP- AC 220 350 5 --- ≤1300 --- --- --- --- AC 220 350 5 --- ≤1300 --- --- --- ---
JLSP-
MA2EA220 Video --- --- 5 ≤60 ≤600 100 --- ≤0.3 RJ45 MA2BFMA220 Video --- --- 5 ≤30 ≤600 10 50 ≤0.3 BNC
Power and AC 24 30 5 --- ≤400 --- --- --- ---
JLSP- video in Power and AC 24 30 5 --- ≤400 --- --- --- ---
JLSP-
MA2EA024 single unit video in
Video --- --- 5 ≤60 ≤600 100 --- ≤0.3 RJ45 MA2BFMA024 single unit Video --- --- 5 ≤30 ≤600 10 50 ≤0.3 BNC
JLSP- DC 24 30 5 --- ≤400 --- --- --- ---
JLSP- DC 24 30 5 --- ≤400 --- --- --- ---
MA2ED024 Video --- --- 5 ≤60 ≤600 100 --- ≤0.3 RJ45 MA2BFMD024 Video --- --- 5 ≤30 ≤600 10 50 ≤0.3 BNC

48 http://www.ahjinli.com http://www.ahjinli.com 49
Signal surge protective device Jinli Electric SPD Specialist Signal surge protective device

Coaxial surge protec ve device

Low insertion loss and low voltage Protection Low insertion loss and low voltage protection level
Fast response: action within nanosecond Fast response: action within nanosecond
High rate transmission Large discharge current capacity
Large discharge current capacity Wide frequency signal transmission
BNC connection Optional different interface
Power, data and video in single unit

JLSP-CC50BFM
JLSP-MA3BFM

JLSP - M A 3 B FM 97 25
Nominal voltage JLSP - C C 50 B FM 180
A: AC Power, D: DC Power Max. continuous operating voltage
Input/output:Female/Male Max. frequency range
Interface type: BNC Input/output: Female/Male
Connection:BNC

29
Function 3: power ,data and video in single unit
Impedance
Housing material: aluminum
Housing material:copper
Multi-function SPD Coaxial surge protective device
JINLI surge protective device JINLI surge protective device
PE

Technical parameters
Max. Nominal Protection Protection
Nominal continuous discharge level Up level Up
Max. data Impedance Insertion
Technical parameters
Model Function Application voltage operating current (line-line) (line-PE) connecton
rate (Mbps) (Ω) loss (dB)
Un(V) voltage (8/20μs) (V) (V)
Uc(Vdc In(kA) (B2:4kV) (B2:4kV) Max.continuous Nominal discharge Protection level Up
Model operating voltage current(8/20μs)In (line‐PE)(V) Frequency(GHz) Impedance(Ω) Insertion loss (dB)
AC 220 350 5 --- ≤1300 --- --- --- ---
JLSP- Uc(Vdc) (kA) (B2:4kV)
MA3BFMA2 Video --- --- 5 ≤30 ≤600 10 50 ≤0.3 BNC
JLSP-
20 180 10 ≤800 3 50 ≤0.3
Data --- --- 5 ≤30 ≤600 --- --- ≤0.3 --- CC50BFM3G180

AC 24 30 5 --- ≤400 --- --- --- --- JLSP-


JLSP- 180 10 ≤800 5.3 50 ≤0.3
Power and CC50BFM5G180
MA3BFMA0 video in Video --- --- 5 ≤30 ≤600 10 50 ≤0.3 BNC
24 single unit
Data --- --- 5 ≤30 ≤600 --- --- ≤0.3 ---

DC 24 0 10 --- ≤400 --- --- --- ---


JLSP-
MA3BFMD0 Video --- --- 5 ≤30 ≤600 10 50 ≤0.3 BNC
24
Data --- --- 5 ≤30 ≤600 --- --- ≤0.3 ---

50 http://www.ahjinli.com http://www.ahjinli.com 51
Signal surge protective device Jinli Electric SPD
JinliSpecialist
Electric SPD backup protector

Telecom surge protec ve device


The protector device must be connected in series with SPDs to avoid the risk of degradation of SPDs
Low insertion loss and low voltage protection level
JLSP-DAE Fast response: action within nanosecond according to IEC61643-12. As the conventional protective device can not cooperate very well with SPDs, it
Large discharge current capacity can’t timely disconnect the power supply when the circuit is abnormal or SPD is degraded, which could lead to
High rate transmission fire and equipment damage.
RJ45 connection The defects of conventional protective device are as follow:
Available for telecom networks • Difficult to determine the setting value of protection current
• Difficult to balance the large lightning impulse current and small follow current of power frequency
• Easy stripping or damage under lightning impulse
• Exist protection blind areas:Don’t disconnect under lower follow current
84 25 • High residual voltage
JINLI SCB series backup protector can provide reliable protection to avoid the above shortages, and the
JLSP - D A E remote status indicator is available with integrated remote terminal.

25
Interface type:RJ45
Housing material: aluminum
Data surge protective device
JINLI surge protective device
PE

Technical parameters
Nominal
Max.continuous Protection level Protection level Up
Nominal voltage discharge current Max. data rate
Model operating voltage Up(line-line)(V) (line-PE)(V) Insertion loss (dB)
Un(V) (8/20μs)In (Mbps)
Uc(Vdc) (B2:4kV) (B2:4kV)
(kA)

JLSP-DAE 5 8 5 ≤30 ≤600 100 ≤0.3

Mul -port integrated signal surge protec ve device


JLSP-ISE5 Integrated multiple line surge protective device
Low insertion loss and low voltage protection level
Fast response: action within nanosecond
Large discharge current capacity
High rate transmission
Optional different interface
Rack mounting

JLSP - I S E5
Input/output: Female/Male
Connection:RJ45
Impedance
Housing material:copper
Coaxial surge protective device
JINLI surge protective device

Technical parameters
Max.continu Nominal Protection Protection
Data rate
Nominal ous discharge level Up level Up
Impedance (Mbps) Insertion loss Protection
Model voltage operating current (line-line) (line-PE) Connection
(Ω) / Frequency (dB) circuit
Un(V) voltage (8/20μs)In (V) (V)
(MHz)
Uc(Vdc) (kA) (B2:4kV) (B2:4kV)

JLSP-IS16E5 5 8 5 ≤60 ≤600 --- 100 ≤0.3 16


RJ45
JLSP-IS24E5 5 8 5 ≤60 ≤600 --- 100 ≤0.3 24

52 http://www.ahjinli.com http://www.ahjinli.com 53
SPD backup protector Jinli Electric SPD
JinliSpecialist
Electric SPD backup protector

Selectively disconnect according to the difference of amplitude and Selectively disconnect according to the difference of amplitude and
frequency characteristics between lightning current and follow current frequency characteristics between lightning current and follow current
Don’t trip when withstanding the maximum discharge current of SPD Don’t trip when withstanding the maximum discharge current of SPD
Timely disconnect under small follow current Timely disconnect under small follow current
Low residual voltage and fast response Low residual voltage and fast response
Handle closing with status indicator window (Red or Green) Handle closing with status indicator window (Red or Green)
Built-in remote communication terminal to transfer SCB status Built-in remote communication terminal to transfer SCB status
Various models to meet the needs of T1 SPD Various models to meet the needs of T2、
T3 SPD

JLSP-SCB1 JLSP-SCB2

JLSP - SCB 1/25 / JLSP - SCB 2/25 /

No. of pole No. of pole


Breaking capacity:L(Low)、M(Medium)、H(High) Breaking capacity:L(Low)、M(Medium)、H(High)
Impulse current Iimp Impulse current Iimp
T1 T2
Backup protector Backup protector
JINLI surge protective device JINLI surge protective device

Technical parameters Technical parameters


Model JLSP-SCB1/25 Model JLSP-SCB2/40 JLSP-SCB2/80 JLSP-SCB2/100 JLSP-SCB2/120

SPD T1 SPD T2 T2 T2 T2

Nominal discharge current / Nominal discharge current(kA) 20 40 50 60

Max. discharge current / Max. discharge current(kA) 40 80 100 120

Impulse current (kA) 25 Impulse current / / / 25

Low (L)(kA) 35 Low (L)(kA) 20 25 35 35


Short circuit breaking
Short circuit breaking capacity Medium (M)(kA) 50 Medium (M)(kA) 25 35 50 50
capacity

High (H)(kA) 100 High (H)(kA) / 50 100 100

Rated voltage (V) Rated voltage(V) 230/400 230/400 230/400 230/400


230/400
Frequency(Hz ) 50/60
Frequency (Hz) 50/60
Short circuit action current (A) 3
Short circuit action current (A) 3
Protection rating IP20
Protection rating IP20
Dimensions (1P)(mm) 30*82*73
Dimensions (1P)(mm) 30*82*73
Max.cross-sectional area of teminal(mm2) 25
Max.cross-sectional area of teminal (mm2) 25
2 Max.cross-sectional area for remote signaling contact(mm2 ) 1.5
Max.cross-sectional area for remote signaling contact (mm ) 1.5
Operating temperature(℃) -25~+60
Operating temperature (℃) -25~+60
Mounting DIN Rail 35mm
Mounting DIN Rail 35mm

54 http://www.ahjinli.com http://www.ahjinli.com 55
SPD smart monitoring terminal Jinli Electric SPD
JinliSpecialist
Electric SPD smart monitoring terminal

JINLI SPD smart monitoring terminal adopts external transformer coil induced pulse current, which is 1 2 3 4 5 6

compatible with AC and DC power supplies; three 8-segment digital display; Built-in non-volatile storage, it can
save data when power is off and easy to connect with RS485 interface. SPD smart monitoring terminal has the
function of monitoring SPD power off, failure of SPD and count of lightning strike action, the function of remote
control or remote signaling is selectable, Which can remote control related equipment in the site or transmit the
fault information to other equipment.
It is easy mounting with 35mm din rail, and the width of single module is 36mm.
SPD smart monitoring terminal can be directly used with SPD in AC 220V/380V low voltage power 7 8 9 10 1112
JLSP - T 20
distribution system or in 100V~350V DC system.
Series number
Smart monitoring terminal
JINLI brand

JLSP-T20

Wide voltage range Single button to modify terminal address

compatible with AC and DC power supply Single button to change terminal switch

Visual status monitoring: site / remote Wide range of counts

Sound and light alarm 10kV/5kA withstand impulse capability

Automatic screen saver

Installa on diagram

L1 L1 +
L2 L2
L3
N L3 -
N

485GND
485A 485GND 485GND
485B 485A 485A
485B 485B

1 2 3 4 5 6
L1 L2 L3 N
1 2 3 4 5 6 1 2 3 4 5 6
L1 L2 L3 N + - PE

PE
7 8 9 10 11 12

PE
7 8 9 10 11 12 7 8 9 10 11 12

Coil Coil

Coil

(a)AC multi-signaling remote terminals (b)AC single signaling remote terminal (c)DC single signaling remote terminal

56 http://www.ahjinli.com http://www.ahjinli.com 57
SPD smart monitoring terminal Jinli Electric SPD
JinliSpecialist
Electric Company achievement

Technical parameters
MPCL Power Plant project in India
Model JLSP-T20
Cuddalore 2*60W Supercritical coal-fired power plant in India
Power supply (V) AC 85~265 DC 100~350

1circuit for SPD action count Polyethylene (PVC), caustic soda and methanol production complex project in Navoiy
1circuit for remote signaling of SPD failure、1circuit for remote signaling of malfunction、 of Uzbekistan
function
sound and light alarm
1circuit for SPD power on、1circuit for remote control output / remote signaling of 2*150MW thermoelectric project in Bishkek of Kyrgyzstan
malfunction
Initial count current (kA) ≥0.5 3*660MW Coal-fired power plant project in Laos
Lightning count range 0~999

Monitoring
Angren Expansion project of 150MW heating unit in power plant in Uzbekistan
Input of SPD failure alarm Electrical independent contact
Remote control / remote
signaling
Electrical independent contactAC 125V /0.5A DC 30V/2A Technical transformation and expansion of power network (second stage) in Republic
A00/A01:SPD normal/failure;L00/L01:SPD power on/power off; of guinea Bata
Status indicator oA0/oA1:Remote signaling normal/ alarm;
oc0/oc1: Remote control contact disconnect/ close。
2*600MW Iskenderun project Flue gas denitration steel project in Turkey Atlas
Enter into the screensaver mode without alarm and no operation during several
Screen saver 、Sound and
light alarm
seconds.Display the corresponding alarm symbol and flash when fault alarm occurs, and Kaléta Hydropower Plant project in Republic of guinea
the buzzer will sound 8 seconds

Communication methods RS485 Ma Kou 5000T cement production line project in Malaysia
Communication protocol Modbus
Communication 1*660MW power plant engineering in Troitsk of Russia
(for T20) Transmission rate (bps) 9600

Transmission distance (m) ≮800


Congo Hituru copper mine Cobalt hydroxide production line supporting 10KV oil
Power circuit ≤20kA(8/20μs)、10kV(1.2/50μs)-5.0kA(8/20μs)
immersed power transformer project
Impulse capability
485 interface A-BA-PE/B-PE ≤5kV(1.2/50μs)-2.5kA(8/20μs) Pola 225MW Gas combined cycle power plant project in Bengal
Dimensions (mm) 91*36*66
Coal-fired 750MW combined cycle power plant project in Angola
Working temperature / humidity -40~85℃/ <90%

Protection level IP20 Hot rolling and cold rolling of iron and steel Public Auxiliary Project Construction EPC
Housing material Thermoplastic material General Contract Project in Russia
Screw torque (N·m) 0.2
Karakato Steelmaking system engineering in Indonesia
Mounting 35mm DIN rail

Min.cross-sectional area of wire(mm2 ) 0.5 400kV center power plant 400kV Substation reconstruction project in Venezuela
2
Max.cross-sectional area of wire (mm ) 1.5
Kostolac-B power plant first stage project in Serbia
1:SL 2:PL 3:S/PN 4:485GND 5:485A 6:485B 7/8:Connection to induction coil
Connection sign
9/10:Connection to signaling remote of SP 11/12:Defect of signaling remote Mesames 3*135MW CFB Coal-fired power plant project in Philippines
400kV Substation reconstruction project in Venezuela
North Nitrogen Production Line New Project in Vietnam
Eritrea Gold mining and selection project in Africa
PERWAJA Concentrator project in Malaysia
Upper Marty Hydropower Station Nepal

58 http://www.ahjinli.com http://www.ahjinli.com 59

You might also like