DB GammaTwin en 19092013

The GammaTwin is a small, handy dose rate meter approved by PTB for measuring gamma radiation and X-rays. It uses a Geiger-Müller tube detector and displays measured dose and dose rate values digitally with an additional analog dose rate display. It has four preset dose and dose rate alarm thresholds, stores dose readings in memory, and is designed for rough use in an IP54 housing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
140 views1 page

DB GammaTwin en 19092013

The GammaTwin is a small, handy dose rate meter approved by PTB for measuring gamma radiation and X-rays. It uses a Geiger-Müller tube detector and displays measured dose and dose rate values digitally with an additional analog dose rate display. It has four preset dose and dose rate alarm thresholds, stores dose readings in memory, and is designed for rough use in an IP54 housing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Dose Rate Meter

GRAETZ GammaTwin
• small and handy, PTB-approved 1) dose rate meter for the measurement of
gamma radiation and X-rays for ambient dose rate equivalent Ḣ*(10) and
ambient dose equivalent H*(10) (local dose) 2)
• detector: energy compensated Geiger-Müller-tube
• large, digital indication of measured values on LC-display (backlit)
• selectable simultaneous or separate indication of dose and dose rate,
additionally analog indication of dose rate (logarithmic bargraph)
• 4 preset dose and dose rate alarm thresholds; upon request GRAETZ
changes the standard alarm thresholds according to customer requirements
• switchable acoustic single-pulse indication
• automatic and continuous storage of the dose into a non-voltile memory
• storage of the dose and of set parameters even at battery change
• permanent self test
• designed for rough use, housing made of aluminium, protection class IP54
(splash proof)
• menu-driven user navigation
• supplied with a robust nylon bag

1)
Physikalisch-Technische Bundesanstalt, Braunschweig
2)
For detecting the personal dose a measuring instrument with the measurand Hp(10) is required.

Technical Data
Dose rate indication range: 0 nSv/h – 70 mSv/h
Dose rate measuring range: 0.5 μSv/h – 70 mSv/h
Dose indication range: 0 nSv – 1.0 Sv
Dose measuring range: 0.5 μSv – 1.0 Sv
Energy range: 45 keV – 1.3 MeV
7.5 μSv/h, 25 μSv/h,
Dose rate alarm thresholds:
40 μSv/h, 300 μSv/h
200 μSv, 500 μSv,
Dose alarm thresholds:
1000 μSv, 2000 μSv
Temperature range: -20 °C up to +60 °C
Power supply: 2 batteries 1.5 V (type AAA)
Acoustic alarm: 80 dB(A) measured in 30 cm distance
PTB-Approval No.: 23.51 / 10.02
Dimensions: (26 x 66 x 103) mm
Weight: 190 g (with batteries)

Available special version:


GammaTwin S with connection facility for external probes (such as the NaI-
scintillation probe 2002 for high-sensitive β- and γ-measurement or the large-
area probe ABG170 for the detection of contaminations)

09/2013 GRAETZ Strahlungsmeßtechnik GmbH


Westiger Str. 172 • 58762 Altena / Germany
Subject to P.O. Box 81 00 • 58754 Altena / Germany
technical change Phone: +49 2352 7007-0 • Fax: +49 2352 7007-10
E-Mail: [email protected] • Website: www.graetz.com

You might also like