0% found this document useful (0 votes)
727 views2 pages

7 Ton Point Load

This document analyzes the load capacity of a 175mm thick concrete slab on grade subjected to concentrated post loading. It calculates the cracking moment capacity, ultimate moment capacity due to rebars, effective load radius, ratio of load radius to radius of relative stiffness, and checks that the internal, edge, and corner load capacities exceed the factored loads for single point, dual separate points, and dual combined points. It also checks punching shear capacities and determines shrinkage reinforcement requirements using the subgrade drag method.

Uploaded by

arvind sharma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
727 views2 pages

7 Ton Point Load

This document analyzes the load capacity of a 175mm thick concrete slab on grade subjected to concentrated post loading. It calculates the cracking moment capacity, ultimate moment capacity due to rebars, effective load radius, ratio of load radius to radius of relative stiffness, and checks that the internal, edge, and corner load capacities exceed the factored loads for single point, dual separate points, and dual combined points. It also checks punching shear capacities and determines shrinkage reinforcement requirements using the subgrade drag method.

Uploaded by

arvind sharma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

LOAD CAPACITY ANALYSIS OF CONCRETE SLAB ON GRADE

For Slab Subjected to Concentrated Post Loading


th
Designed as per TR 34 4 Edition
Job Name: Kimberly Clark Subject: Saw-cut Floor Designer: TH
Design Date: 12/03/2020 Analysis Case: Max. Load Capacity Checker: VJ

Spacing, x
Input Data:

Slab Thickness, h = 175 mm P P


Concrete Strength Class = C25/30 Post Post Top of Slab

Char. Concrete Compressive Strength, fck = 25 MPa (cylinder)


Char. Concrete Compressive Strength, fcu = 30 MPa (cube)
Mean Concrete Axial Tensile Strength, fctm = 2.59 MPa
2
Contact Area, Lc × Wc h
Secant Modulus of Elasticity, Ecm = 31 kN/mm

Concrete Poisson's Ratio, μ = 0.15 (Sub-base)


Reinforcing Yield, fy = 500 MPa Typical Loading Scheme
3
Sub-base Modulus, k = 0.050 N/mm
Concentrated Load, P = 70.00 kN Bottom Rebars, As h/3 deep sawn joint

Base Plate Length, Lc = 175 mm Rebar Cover = 30 mm

Base Plate Width, W c = 175 mm


h
Load Spacing, (x<=2h) = 300 mm
Load Spacing, (x>2h) = 1000 mm
Load Safety Factor, γL = 1.20 Typical Saw-cut Joint
Material Safety Factor - Concrete, γc = 1.50
Material Safety Factor - Steel, γs = 1.15
Bottom Rebar Dia., db = 7 mm
Bottom Rebar Spacing, s = 200 mm (assumed)
Saw-cut Joint Spacing, L = 4.0 m

Edge Load Transfer Ratio, ξedge = 15 %

Corner Load Transfer Ratio, ξcorner = 40 %

Calculations:

Capacity Calculations
Design Concrete Flexural Tensile Strength, fctd,fl = 2.46 MPa , = (1.6 − 0.001ℎ)/ (Eqn.1)
Ultimate Cracking Moment Capacity, Mun = 12.57 kNm/m = , (ℎ /6000) (Eqn.2)
2
Area of Steel Reinforcement, As = 192.42 mm /m = (250 ⁄ )
Ultimate Moment Capacity due to Rebars, Mup = 11.52 kNm/m = 0.95 / (Eqn.3)

Check Slab Bending: Single Point Load


Effective Load Radius, a = 98.73 mm = ⁄
Radius of Relative Stiffness, lr = 732.33 mm = ℎ /(12 1 − )
Ratio a/lr = 0.135
Ultimate Factored Internal Load, Pu,i = 84.00 kN
Internal Load Capacity, Pinternal = 268.04 kN P(allow) >= P(actual), O.K. (From Eqn. 21 and Eqn. 22)
Ultimate Factored Edge Load at Joint, Pu,e = 71.40 kN
Joint Edge Load Capacity, Pedge = 118.52 kN P(allow) >= P(actual), O.K. (From Eqn. 23 and Eqn. 24)
Ultimate Factored Corner Load at Joint, Pu,c = 50.40 kN
Joint Corner Load Capacity, Pcorner = 50.57 kN P(allow) >= P(actual), O.K. (From Eqn. 25 and Eqn. 26)

Page 1 of 2
Job Name: Kimberly Clark Subject: Saw-cut Floor Designer: TH
Design Date: 12/03/2020 Analysis Case: Max. Load Capacity Checker: VJ

Check Slab Bending: Dual Point Loads Acting Separately


Effective Load Radius, a = 98.73 mm = ⁄
Radius of Relative Stiffness, lr = 732.33 mm = ℎ /(12 1 − )
Ratio a/lr = 0.135
Ultimate Factored Internal Load, Pu,i = 84.00 kN
Internal Load Capacity, Pinternal = 330.15 kN P(allow) >= P(actual), O.K. (From Eqn. 27 and Eqn. 28)
Ultimate Factored Edge Load at Joint, Pu,e = 71.40 kN
Joint Edge Load Capacity, Pedge = 145.99 kN P(allow) >= P(actual), O.K. (From Eqn. 27 and Eqn. 28)

Check Slab Bending: Dual Point Load Clubbed Together


Effective Load Radius, a = 162.664 mm = 2 + ( − )⁄
Radius of Relative Stiffness, lr = 732.33 mm = ℎ /(12 1 − )
Ratio a/lr = 0.222
Ultimate Factored Internal Load, Pu,i = 168.00 kN
Internal Load Capacity, Pinternal = 327.01 kN P(allow) >= P(actual), O.K. (From Eqn. 21 and Eqn. 22)
Ultimate Factored Edge Load at Joint, Pu,e = 142.80 kN
Joint Edge Load Capacity, Pedge = 147.88 kN P(allow) >= P(actual), O.K. (From Eqn. 23 and Eqn. 24)

Check Slab Punching Shear: Single Point Load


Internal Load Perimeter, u1i = 2522.1 mm
vRd,c = 0.49 MPa Eqn. 13
Ground Reaction Force (Internal Load), Rpi = 4.61 kN Eqn. 31
Design Punching Load (Internal), Ppui = 79.39 kN
Punching Load Capacity (Internal), Ppmax = 181.02 KN P(allow) >= P(actual), O.K. Eqn. 13

Edge Load Perimeter, u1e = 1436.1 mm


vRd,c = 0.49 MPa Eqn. 13
Ground Reaction Force (Edge Load), Rpe = 6.72 kN Eqn. 32
Design Punching Load (Edge), Ppue = 64.68 kN
Punching Load Capacity (Edge), Ppmax = 103.07 kN P(allow) >= P(actual), O.K. Eqn. 13

Corner Load Perimeter, u1c = 805.5 mm


vRd,c = 0.49 MPa Eqn. 13
Design Punching Load (Corner), Ppuc = 50.40 kN
Punching Load Capacity (Corner), Ppmax = 57.81 kN P(allow) >= P(actual), O.K. Eqn. 13

Shrinkage Reinforcement: (assuming subgrade drag method)


Friction Factor, F = 0.50 F = 0.5 (assumed friction factor between sub-base and slab)
Loaded Slab Weight, W = 54.38 kN/m2 W = 25 × (h/1000) + Equivalent UDL
Reinf. Allow. Stress, fs = 300 MPa fs = 0.6fy
Ashrinkage = 181.3 mm2/m Ashrinkage = F×L×W/(2×fs)
2
As, provided = 192 mm /m As(provided) >= As(shrinkage), O.K.

Results:

Design Outcome = SAFE for a Maximum Point Load Carrying Capacity of the Slab = 70.00 kN
Concrete Grade (Cube), fcu = 30 MPa
Slab Thickness, h = 175 mm
Bottom Reinforcement Area, As = 192 mm2/m

Rebar Diameter, db = 7 mm
Spacing c/c, s = 200 mm
Cover to Rebar = 30 mm
3
Modulus of Sub-base to be considered, k = 0.05 N/mm
Maximum Saw-cut Panel Size, L = 4.0 m

Page 2 of 2