Bedford Street, St.
Helens, Merseyside, WA9 1PN, United Kingdom, Tel: +44 (0) 1744 453393
[email protected]
Anchor Flange Design & Dimension Data Sheet
W Maass UK Ltd has a range of standard Anchor Flanges that match ASME B16.5 pressure classess and
comply with design rules and regulations of ASME VIII Division 1 Appendix 2 & ASME II Part D. Detailed
below on Page 1 are the design principles used for the standard Anchor Flange design and on Pages 2
to 4 are outline dimensions sufficient to give an external envelope size. For further dimensional detail
or supply information, contact W Maass UK Ltd.
Anchor Flange Design Principles
1) Anchor flange is considered to be symmetrical,
constant angle hubs and no bolt holes (if bolt holes are
included then it's considered to be a Hanger Flange - see
different W Maass UK Data Sheet).
2) To generate the standard sizes shown in Page 2,
Material Group No. 1.1 as per ASME B16.5 is considered
(typically A105, LF2). Materials of other Group Numbers
are also acceptable subject to review by W Maass UK
Ltd.
3) The range of Anchor Flanges shown on Pages 2 & 3 correspond to ASME B16.5 pressure classes.
Maximum Allowable Operating Pressure is per ASME B16.5 for Material Group No. 1.1 at temperature
-29°C to +38°C. Other Operating Pressures & Temperatures are also acceptable subject to review by W
Maass UK Ltd.
4) Allowable flange stress is derived from ASME II Part D Table 1A for ASTM A105 material at
temperature -29°C to +38°C for all Anchor Flanges except those suffixed with (F65). For these Anchor
Flanges, it is necessary to use allowable stresses according to ASTM A694 F65 to achieve a practical
flange design.
5) Bearing Stress of the anchor flange face at full Thrust Load is limited to 12MPa maximum. This is
typical for most concrete embedded applications but should be checked for each application.
6) The bore size shown on Pages 2 & 3 is indicative only, used for generating the Anchor Flange design.
The corresponding wall thickness maintains pipe hoop stress below 50% SMYS.
7) The Thrust Load used to develop the standard Anchor Flange designs correspond to the Maximum
Allowable Operating Pressure applied to the bore area of the flange. Other Thrust Loads are also
acceptable subject to review by W Maass UK Ltd.
Note: The design approach used in this Data Sheet is the most conservative available. There are options available
to refine the Anchor Flange designs to reduce size and weight. Contact W Maass UK Ltd for more information.
Doc: WM_2017_007 Rev A Page 1 of 4
Bedford Street, St. Helens, Merseyside, WA9 1PN, United Kingdom, Tel: +44 (0) 1744 453393
[email protected]Anchor Flange Design & Dimension Data Sheet
The following dimensional data is provided as indicative information only suitable for use to establish an external
envelope size of the Anchor Flange. Contact W Maass UK Ltd for further information.
ASME B16.5 Class: 150lb
Nom Size MAOP Thrust (kN) Pipe OD (d) Bore Flange OD Flange Lnth Flange Thk Weight
(MPa) (mm) (b) (mm) (D) (mm) (L) (mm) (T) (mm) (kg)
2
Use 600lb
3
4
5
6
Use 300lb
8
10
12
ASME B16.5 Class: 300lb
Nom Size MAOP Thrust (kN) Pipe OD (d) Bore Flange OD Flange Lnth Flange Thk Weight
(MPa) (mm) (b) (mm) (D) (mm) (L) (mm) (T) (mm) (kg)
2
Use 600lb
3
4 5.1 48,162 114.3 109.6 150.0 60.2 10.0 1.2
5 5.1 73,792 141.3 135.6 185.0 62.9 12.0 1.9
6 5.1 104,687 168.3 161.5 220.0 80.8 14.0 3.6
8 5.1 177,423 219.1 210.3 280.0 86.3 18.0 6.3
10 5.1 275,455 273.0 262.0 346.0 90.0 20.0 10.0
12 5.1 402,025 323.8 310.7 415.0 110.6 24.0 18.0
ASME B16.5 Class: 600lb
Nom Size MAOP Thrust (kN) Pipe OD (d) Bore Flange OD Flange Lnth Flange Thk Weight
(MPa) (mm) (b) (mm) (D) (mm) (L) (mm) (T) (mm) (kg)
2 10.2 24,622 60.3 55.4 90.0 45.3 10.0 0.5
3 10.2 53,465 88.9 81.7 125.0 49.1 12.0 1.0
4 10.2 88,836 114.3 105.3 165.0 67.5 14.0 2.3
5 10.2 135,762 141.3 130.1 200.0 73.1 18.0 3.8
6 10.2 192,603 168.3 155.0 240.0 91.8 20.0 6.7
8 10.2 326,423 219.1 201.8 310.0 100.9 26.0 13.0
10 10.2 506,783 273.0 251.4 380.0 110.1 32.0 22.2
12 10.2 712,934 323.8 298.2 450.0 134.2 38.0 37.8
MAOP = Maximum Allowable Operating Pressure
Doc: WM_2017_007 Rev A Page 2 of 4
Bedford Street, St. Helens, Merseyside, WA9 1PN, United Kingdom, Tel: +44 (0) 1744 453393
[email protected]Anchor Flange Design & Dimension Data Sheet
The following dimensional data is provided as indicative information only suitable for use to establish an external
envelope size of the Anchor Flange. Contact W Maass UK Ltd for further information.
ASME B16.5 Class: 900lb
Nom Size MAOP Thrust (kN) Pipe OD (d) Bore Flange OD Flange Lnth Flange Thk Weight
(MPa) (mm) (b) (mm) (D) (mm) (L) (mm) (T) (mm) (kg)
2 15.3 33,905 60.3 53.1 95.0 47.1 10.0 0.6
3 15.3 73,622 88.9 78.2 135.0 53.7 14.0 1.5
4 15.3 122,650 114.3 101.0 175.0 74.8 18.0 3.4
5 15.3 187,439 141.3 124.8 215.0 81.2 22.0 5.9
6 15.3 265,916 168.3 148.7 260.0 102.6 26.0 10.8
8 15.3 450,673 219.1 193.5 330.0 115.1 34.0 20.7
10 15.3 699,685 273.0 241.1 410.0 126.0 40.0 36.0
12 15.3 984,308 323.8 286.0 490.0 163.5 58.0 72.3
ASME B16.5 Class: 1500lb
Nom Size MAOP Thrust (kN) Pipe OD (d) Bore Flange OD Flange Lnth Flange Thk Weight
(MPa) (mm) (b) (mm) (D) (mm) (L) (mm) (T) (mm) (kg)
2 25.5 47,442 60.3 48.6 100.0 54.5 14.0 1.0
3 25.5 103,015 88.9 71.7 145.0 62.8 18.0 2.5
4 25.5 172,571 114.3 92.8 190.0 87.2 24.0 5.9
5 25.5 263,730 141.3 114.7 235.0 97.0 30.0 10.5
6 25.5 374,148 168.3 136.6 280.0 119.9 34.0 17.8
8(F65) 25.5 760,366 219.1 195.6 375.0 123.6 44.0 33.1
10(F65) 25.5 1,188,703 273.0 243.4 465.0 142.2 58.0 64.4
12(F65) 25.5 1,672,253 323.8 288.8 560.0 169.4 66.0 108.4
ASME B16.5 Class: 2500lb
Nom Size MAOP Thrust (kN) Pipe OD (d) Bore Flange OD Flange Lnth Flange Thk Weight
(MPa) (mm) (b) (mm) (D) (mm) (L) (mm) (T) (mm) (kg)
2 42.6 58,104 60.3 41.7 108.0 61.8 16.0 1.5
3 42.6 126,167 88.9 61.4 155.0 74.6 22.0 3.9
4 42.6 213,656 114.3 80.0 205.0 102.9 30.0 9.3
5 42.6 326,519 141.3 98.9 250.0 112.5 36.0 15.9
6 42.6 463,225 168.3 117.7 300.0 134.9 42.0 27.2
8(F65) 42.6 1,092,228 219.1 180.8 420.0 146.8 56.0 49.1
10(F65) 42.6 1,695,719 273.0 225.3 520.0 162.4 70.0 107.2
12(F65) 42.6 2,385,517 323.8 267.2 620.0 193.0 84.0 183.4
MAOP = Maximum Allowable Operating Pressure
Doc: WM_2017_007 Rev A Page 3 of 4
Bedford Street, St. Helens, Merseyside, WA9 1PN, United Kingdom, Tel: +44 (0) 1744 453393
[email protected]Anchor Flange Design & Dimension Data Sheet
Figure 1 below shows the W Maass UK Ltd Anchor Flange standard geometry and information relating to
the dimensions.
Figure 1 - W Maass UK Ltd standard Anchor Flange Geometry
Notes
1) Calculated flange stresses are compliant to ASME VIII Div 1 rules. Also, flange thickness (t) complies with
ASME VIII Div 1 Appendix 2 Section 2-14 Rigidity Check.
2) Thrust Load is calculated by: MAOP * b2 * p / 4
Doc: WM_2017_007 Rev A Page 4 of 4