Small. Powerful. The perfect fit.

High performance in an
affordable, truly compact design Fast and easy to use

• Reliable and accurate patient results • Results in less than


• Standard barcode reader 60 seconds
• Multiple languages available • Small sample size
• Open-mode one touch operation • Low reagent consumption
• Auto shutdown • Zero daily and weekly
maintenance
• Quiet and lightweight

TM
CELL-DYN Emerald™ SPECIFICATIONS

Demographics CELL-DYN Emerald Reagents


• Sequence number
Reagent
• Alphanumeric specimen ID
Description Size and List Number
• Alphanumeric patient ID
• Date & time analyzed CN-Free Diff Lyse 960 mL
• Patient name List No. 09H47-02
• CBC with 3-part differential
Diluent 10 L
• Flagging and Alerts
List No. 09H48-02
Dispersional Data Alert Cleaner 960 mL
• O perator-defined patient limits for high and panic values List No. 09H46-02
• S ystem-defined limits for reportable range and analytical
measurement range
• S uspect parameter flags caused by interfering substances CELL-DYN Emerald Controls
or sample abnormalities and Calibrators
• S uspect parameter flags generated when WBC data indi-
cates possible presence of an abnormal population
CELL-DYN 09H70-01
Standards & Safety Compliance 18 Plus Calibrator
• UL61010A-1 CELL-DYN 09H69-01
• CE Mark 18 Plus Control 09H69-02
• CAN/CSA C22.2 No. 1010.1-92
• ETL Mark
• IEC 61000-3-2, 3-3, 4-2, 4-3, 4-4, 4-5, 4-6, 4-8, 4-11
Technology & Methods • Harmonics emissions
• Electronic impedance
• Absorption spectrophotometry
• EN 55011 and EN 61000 Main Menu
• Electronic valves Peripheral Devices
• Cyanide-free lyse reagent • Dot Matrix or Inkjet printer
• LCD color touch screen • USB thumb drive
• RS232 and TCP/IP LIS interface • Handheld barcode scanner
• USB ports
Physical Dimensions
Throughput • Height 13.8” (35cm)
• Up to 60 samples per hour • Width 9.9” (25cm)
• Depth 13.4” (35cm)
Sample Size • Weight 19.85lbs (9kg) (without on-board reagents)
• 9.8 μL
Parameters
Specimen Data Management
• Search by date or sequence number White Cells Red Cells Platelets
• Flagging for patient limit sets WBC RBC PLT Datalog File
• Flagging for panic values
LYM # HGB MPV
• 1,500 records with histograms on internal memory
• Up to 60,000 on external USB thumb drive LYM % HCT
• Flagging for patient limit sets
MID # MCV
• Programmable patient limits
• Programmable report units MID % MCH
• S tandard barcode reader (reads code 128, code 39, and GRAN # MCHC
interleaved 2 of 5)
GRAN % RDW
Quality Control
• 6 control files
• 100 runs per file
• Levey-Jennings graphs
• Upload/download control information
• eQC Online peer review program

CELL-DYN Emerald is a trademark of Abbott Laboratories in the U.S.

www.abbottdiagnostics.com
1-800-323-9100
© 2008 Abbott HM-08-33854v1-17.3 Oct Printed in USA