PDS01.03.002-A - Wouter Witzel - EVCS Installation

This document provides installation data for rubber lined eccentric butterfly valves, including disc protrusion dimensions, flange thickness specifications, and minimum bolting lengths for inline and dead end installations. Sizes range from 50mm to 300mm. A formula is given to calculate the minimum bolting length between flanges based on flange thickness, hardware dimensions, and thread pitch. Only standard available bolt lengths are listed, and any deviation from the assumptions requires recalculation of the bolt length.

Uploaded by

Vilius Bukys
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
117 views1 page

PDS01.03.002-A - Wouter Witzel - EVCS Installation

This document provides installation data for rubber lined eccentric butterfly valves, including disc protrusion dimensions, flange thickness specifications, and minimum bolting lengths for inline and dead end installations. Sizes range from 50mm to 300mm. A formula is given to calculate the minimum bolting length between flanges based on flange thickness, hardware dimensions, and thread pitch. Only standard available bolt lengths are listed, and any deviation from the assumptions requires recalculation of the bolt length.

Uploaded by

Vilius Bukys
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GD200 01 03

Product data sheet Valves Rubber Lined - Centric EVCS

PDS01.03.002-A Installation Data - EVCS

TYPE EVCS IN LINE INSTALLATION DEAD END SERVICE

SIZE DISC PROTRUSION FLANGE THICKNESS BOLTING LENGTH (L)


EN 1092 EN 1092 ASME B16.5
DN NPS X Y PN 10 PN 16 CL 150
PN 10 PN 16 CL 150

50 2" 25 4 18 18 19.1 100 100 4¼"


65 2½" 46 10 18 18 22.4 110 110 4½"
80 3" 66 17 20 20 23.9 110 110 4¾"
100 4" 86 24 20 20 23.9 120 120 5"
125 5" 112 35 22 22 23.9 130 130 5¼"
150 6" 140 47 22 22 25.4 130 130 5½"
200 8" 191 70 24 24 28.5 140 140 5¾"
250 10" 241 91 26 26 30.3 150 150 6½"
300 12" 290 111 26 28 31.8 160 180 7"

FLANGE BOLTING LENGTH

The minimum bolting length of a wafer type valve between flanges with through bolting can be calculated with the
formula:

L MIN = 1 x FtoF + 2 x Flange Thickness + 1 x H NUT + 2 x H SPACER + 1 x pitch thread

The table shows the calculated bolt lengths for ISO PN and ASME flanges, based on the following assumptions:
- flange thickness of a steel welding neck flange according EN 1092 and ASME B16.5;
- use of hexagon head cap screws, two spacers and a nut;
- standard available bolt lengths.

Important: Only as guidline, any deviation requires recalculation of the bolt length.

Prepared: T. Pünt Checked: - Approved: -


www.eurovalve.nl -1-/1 04.11.2005
This data sheet is not contractual and may be changed without notice. All rights reserved.