QuickGuide: DM32 Dual-Channel Digital manometer
Tap in the boxes on
the touch sensitive
Home screen
Control fan speed
[Channel A]
pressure difference
Fan speed, time average, across blue “input” and
network and battery red “ref” ports
status
Baseline being subtracted
[Channel B]
Select Device and Range
….across green “input”
and yellow “ref” ports
Set to any pressure
Dimensions eliminate
calculations
On/Off and Home
On for charging,
off when charged
Recharge using micro-
USB to USB cable
Computer connection
with Ethernet cable
Get latest updates online
1: Make connections and power On
Plug in color-
coded tubes
Connect ethernet-style Press for 2 seconds
Cable from gauge to fan to turn On /Off
2: Set Range or Device
Tap Tap
to select Device to select Range
Tap for options
OR Tap for more choices
Tap a Range to select Tap [Change Device]
and return Home to see options Tap to return Home
3: Choose desired Result
Tap [Channel B] Tap to select Result Tap to change units
Tap
for previous screen Tap for more
Page 2 of 4
4: Set Area and Volume
Tap and [Set] area for:
Flow/Area
EqLA10/Area
EfLA4/Area
Tap and [Set] volume for:
ACH (Air Changes per Hour)
5: Run a test
Tap to target a pressure
OR
Tap to set to a speed
a Tap to “Hold”,
Tap to release
d Tap
b Tap to change Result
Tap to calculate Result
d exactly at (@) the “Set
Pressure”
a
c Tap or
to decrease or increase
b
c e c
Tap
e Tap to turn fan Off
to remove @
Page 3 of 4
Change gauge Settings
Tap [Settings] allows you to change:
[Baseline]: Measure and remove Bias/Baseline pressures.
Tap [Capture Baseline] to begin sampling
Tap [End Capture] after 15 to 60 seconds
The displayed Baseline pressure is subtracted from all
future [Channel A] readings.
Tap [Settings]>>[Baseline] >>[Clear Baseline] to
remove.
[Area]
[Volume]
[Time Averaging]
[Result to be displayed]
[Network] Shows connection information.
[Default @ Pressure] Adjust the pressure to which results
are extrapolated.
[Power down time] Enter time, “Off” means never.
[Sound] On or off.
[Ducts=0.6, House=0.65] Enter “n” for ducts or house.
[Firmware]: View current version or initiate update process.
[Re-calibrate touchscreen] Adjust the sensitivity.
Tap OR
to return to Home
Connect many gauges to a computer
Tap
Tap …
Tap [Network]
Tap [Status] and
select “Wired “
If connecting to Switch or PC, OR
tap [Mode] and select “Static “.
For 2nd gauge enter IP Address: 169.254.1.2
If connecting to a Router just
For 3rd gauge enter IP Address: 169.254.1.3 tap [Mode] and select “DHCP “
……
Page 4 of 4