12.
Design of Vertical Stirrup
Given Data : Find : Spacing S
Compressive strength of concrete f'c := 25 MPa
Yeild strength of reinforcement for bending moment fy := 390 MPa
Yeild strength of reinforcement for shear forces fyt := 390 MPa
Width of beam bw := 300 mm
Height of beam h := 700 mm
Effective depth of beam d := h − 90 mm
Maximum Shear forces for simple beam Vu := 250kN
Number leg of Strirrup n := 2
Strirrup Diameter dv := 10 mm
Solution Reference
Modification factor
λ := λ=1 (ACI.8.6.1)
Shear strength of concrete
ϕ := 0.75 (ACI.9.3.2.3)
f'c
Vc := 0.17 λ MPa bw d Vc = 155.55 kN (ACI.11.2.1.1)
MPa
ϕVc := ϕ Vc ϕVc = 116.663 kN
f'c
Vs.max := 0.66 MPa bw d Vs.max = 603.9 kN (ACI.11.4.7.9)
MPa
Vs < ϕVs.max Enlarge the Section (ACI.11.4.7.9)
Av fyt d
Vs = (ACI.11.4.7.2)
S
Vu ϕVc + ϕVs (ACI.11.1.1)
Vu
Vs := − Vc Vs = 177.783 kN
ϕ
ϕVc
Calculate Shear Reinforcement := "No Need Shear Reinforcement" if Vu < (ACI.11.4.6.1)
2
"Shear Reinforcement is Required" otherwise
Calculate Shear Reinforcement = "Shear Reinforcement is Required"
Number leg of Strirrup n=2
Strirrup Diameter dv = 10 mm
π dv
2
Area of Strirrup Av := n
4
Minimum Shear reinforcement
(ACI.11.4.6.3)
Av fyt Av fyt
Smax := min ,
0.35 bw MPa
0.062 f'c MPa bw
Smax = 583.439 mm
ϕVc
min , 600 mm if
d
S := > Vu
2 2
ϕVc
min Smax , , 600 mm if
d
Vu < ϕVc
2 2
if Vu > ϕVc
Av fyt d d
min , Smax , , 600 mm if Vs 0.33 f'c MPa bw d (ACI.11.4.5.1)
Vs 2
Av fyt d d
min , Smax , , 300 mm if 0.33 f'c MPa bw d < Vs Vs.max (ACI.11.4.5.3)
Vs 4
"Enlarge The Section" otherwise
S := Floor ( S , 10 mm) = 210 mm