0% found this document useful (0 votes)
317 views102 pages

Reference Manual of Module Switch and Jumper Settings For Ne

ABB DCS

Uploaded by

Dang Jinlong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
317 views102 pages

Reference Manual of Module Switch and Jumper Settings For Ne

ABB DCS

Uploaded by

Dang Jinlong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 102
L760273 f ‘90 fi Reference Manual REFERENCE MANUAL OF MODULE SWITCH AND JUMPER SETTINGS FOR NETWORK 90 / INFI 90 Baillely Bailey Canada Inc. NOMENCLATURE SHEET NUMBER NOMENCLATURE cac 74 75,76 77.78.79 Mapcor : iLco: 28 30.31 32.33 forces 7 cucoz 29 30 31 32,33 MORSO2 Bee crco3 29 30,31 3233 © MROOS a cuco+ 29 30°31 32.33 MSPMOt Bo 3¢ 50 51,52 53 NB MC? ’ “EATHO! i NBTMOI 7 —8MMO1 9394 N CTO! 46 47 FomMe! N Tot 3458 SACO! 84 85 86 Noe tne MANMOS 7 NPTOT 8990, EOD 3 NPTC FUTURE was 02 6 at 2 | eewor : NLMCS 1.2.7 MASMO2 18 NN SO1 43044 bese 13 NNPMOA 67 MaSOS 18 Nperc* 6 Meee 7 NPPTOV 87 88 esr 34 30 NPTMO} 7 _ MCOMLS a NSMf oe MCO 494 Ww MOS 92 20 M_SMO4 24 ee Me SM35 25 Pgwion 20ST nS." PEN OFF ANE hereee 27 Dee QU VALENT peaee Fererass Noss03 seats MOSCS4 (OUT MFCSOI = MH5E01 vines MMFCO3 eee MMFCO4 atti MMFCOS: Ww | MMEPOT 200 NOT USE 4 LEAD Pernt Tt MMEPO2 rae Sock me Swrones, UsaPn Te ELE UF an CAUSE SHORT ORCS” ee a Maee Phe om Cee BUTE 8 a GE AL760273K SHT P1 Y \ NE TWORS cen ae Baileys CAD FLE— 760273 \ NDEX FOR MODULE SW TCH 2 DO NOT USE A LEAD PENG AL760273G SHT P2 peTeone 07 CAD FLE | 7602732 SETTNGS cont NOMENCLATURE SHEET NUMBER NOMENCLATURE SHEET NUMBER NAMMO2 16 NDSMO5S 25 NAMMOZA 2 Nosoo1 7 NAMMO3. 37 NDSOO2 27 NAOMOt 19 NOSOO3 2 NAS O} 38 Nosoo# Po NaS 02 35 NFCSO1 31 NASMO" 7 NGCMO* 6465 NASMOZ "3 NSCMC2 87 88 NASMO3 18 NGCMOS bonne . HHSSOT 70 ho : os z . HAOs 37 a se55 Hawa? se 2 NN AQOT so a Z NeLot 6292 = NCSO1 60 NoS02 3338 Nweot & a NMPOT 62 83 NCOMO3 a t 1 2 Noowos 2 NUMOZ (FOR POU) 13 NCOMO2 (VLS ) n SEXESAL NOTES jNCOWOS (vist) ” 1 SWITCH POS NS “OPEN', ‘OFF AND. NcOMOs (VLS 4 PNOT_ON. APs EQU VALENT Nemer (*S? 10 Se BELOW NOCSO3 1314 2 NO S01 5 TOG NDLSO2 28 OPEN NDSO1 26 ON NDS O2 40 7 NosMo3 23 TTDI NOSMO4 24 veseee tasese7s TOU00000 OFF LTO SLOE THE SWICHES SRAPH TE BULD UP CAN CAUSE A SHORT CRCUT USE A PROBE OF OTHEP SU TABLE OBJECT Oo ley: NOMENCLATURE. NLMOZ NLMOZ NLMO2 | NLMO2 NOMO2 NLSOT NLMMO1A | NUMMO2 | NLSMO1 NLSMa2 NMFCOI NMFCO2 NMFCO3, NMFCO4 | NMFCOS NwPCO" NPTMOIA NORCO1 NQRCO2 NQRSOt NQRSO2 NR OOt NR 002 NSBMO1 NSCMO1 NSMO1 NSPMO1 NSSMO1 NTCLOI NTMPOt AL7602730 SHT PS \CAO FILE= 76027303 NOEX FOR MODULE SW TCH ud) cud2) uU03) PPGOI) C02) Wadhecks DORNANNNN SN GuUbU 1 SWTCH POS TIONS "OPEN" PNOT_ONT ARE £QU VALENT 20 NOT USE A LEAD PENCL TC SUOE THE SMTOFES GRAPH TE BULC 19 ‘GAN CAUSE A SHOPT CRCUT USE * PROBE OP OTHED SL TABLE OBJECT NETWORK $0/NF 90 BUS AND LOOP NTERFACE MODULE SWTCH SETTNGS NOTE NOTE FOR MORE INFORWATION ON NBIMO2/NUNO2 SEE PRODUCT NSTRUCTION £93 908-1 FOR MORE NFORMATION ON INBMOZ/NLINOS SEE PRODUCT NSTRUCTON F95~60S AL760273€ SHT 1 CAD FILE— SWTCH OPEN = LOGE 1 (POS 5S THE LEAST SGNF CANT 87) SWI § SET TO THE MODULE ADDRESS (0 OR 1) SW1-2 TO 4 NOT NORWALLY USED SWI-i DEFNES REDUNDANT BM'S SUPPLIED (O=NO, 1=YES) Vi ENABLE — OSABLE STATUS ALARM (1 2 ENABLE, 2~3-D SABLE) 32 SELECT NODE OF OPERATION (1=BMOIA 298 M02) sw a 2 ‘Ppp! 73 | v2 FLAT DMA CABLE (BNOZ TO LMOT]P4 CONNECTOR) 2 eT res | nae 1 Beas wi Prsasere T1000 SWITCH OPEN = LOGC 1 (POS 8 S THE LEAST SGNFCANT BT) SW2 -3 TO 8 SELECTS PCU NODE ADORESS (0 63) <1 OPEN = ENABLES UM TO CONTINUE RUNNNG 30 SECONDS AFTER 4 DOUBLE LOOP FAULT occuRS : CLOSED ~ NORMAL OPERATION ‘SWS DAGNOSTIC/DISPLAY SWITCH REFER TO SHT. 3 FOR STANDARD JUMPER SETINGS (NOT APP CABLE TO NLMO3) CA owe Talsllslel7lelels 141s 16 fol | fofolrfolelo: @ NETWORK 90/NF 90 7, eas Sabo: W\\ ucts ~ TTA P WICH SE PART OF CUO! PCOt he pes 7 T2345 Fob suffi] NeTMora ‘OPEN NPTWOt FXED ADDRESS - 2 NOTE 1 SWI S NOT NORMALLY USED (0 AGNOSTC/D SPLAY LED. s) 21 ENABLE ~ DSABLE STATUS ALARM (1 2 ENABLE 2 3-D SABLE)| 3.2 = NOT USED | SW a 12) 3)4}5 1/3 ' ojofo FLAT DMA CABLE (NPTMOIA/NPTMO1 TO NLMO2/NLMO3 P4 CONNECTOR) ~ P4ES 12345676 sw] 1 iss | ut, 2 OPEN {| | eve NEMO | 3 12345678 ncHGd | | sw 1 LSB oy OPEN | NOTE 1 SwGN O6EN = 1GG0 1 (ROS BIS THE LEAST SGNFCANT 91) 2 Sw2 ~3 70 8 SELECTS PCU NODE ADDRESS (0 63) uM TO. CONTINUE RUN NG_30 SECONDS AFTER A DOUBLE LOOP FAULT OCCURS ‘OR TROUBLE SHOOTING PURPOSE ONLY SEE EN 670-N90~2667 ‘cuosep = NORMAL OPERATION 3. §ML_S DAGNOSTC/O SPLAY SMICH ONLY. 4 REFER 10 SrT”3 FOR STANDARD WUMPER’SETINGS (NOT APPUCARLE TO NUMOS) swt (TYP CAL) sw2 ‘J2]3]4]s]6]7Ja[s]2]3]4]s]6]7]8 [ofofs[+folofrfofofo SEE PRODUCT NSTRUCTION £95-905 FOR MORE NFORMATION ON NUMOZ/NPTWOIA SEE PROCUCT NSTRUCTION £96~620 FOR MORE NFORMATION ON NUMO3/ NPTMG! NETWORK 80/NF 90 JAL760273€ SHT 2 = CAD FILE 76027302 \)\. Selvcckoc, 7/AN00175 NUMO2 AL7602738 SHT 3. CAD FLE- 76027303 ws STANDARD ALTERNATE POS TON POS TION CHP 25132 2732 TyPE=Us| 2532/99401 2 yt) 2 El +1 wt pee eee 3 T23 123 2 + = ALWAYS _NSERTED (USED FOR 3 [COMPUTER ZED TEST SETUP. ONLY) NETWORK SO/INF 90 \wexiee ¢ © © T/ai00175 : SWS AL 7602730 SHT. 4 CAD FILE 76027304 RAL NTERFACE M Lor FC OT NsiMOt NS MOT NOTES. 1 SWICH SET OPEN = LOGC 1 2. SW2 SELECT COMPUTER PORT ADDRESS cfo}cfo)cfo}cho 3 Sw3_SELECT FORT OPTONS AND SW4 SELECTS PORT OPERATON OPTIONS finect Shawn Tec roe OR a fsean ‘twee oem ene ros me ; ; se 8 foe] SHA) SROey tte owas "o we Te bart oe [COMPUTER PORT ADDRESS DEFNTON ea Sae [ADDRESS = (Swa POLE 4) & (SWZ POLES 1=5) “ONLY VAUD WHEN Sha POLES = T 4. JP1_AND JP2 SELECT ROM TYPES [ONPER TET FOE ALY | UTS LY i Tz Ty e+ {| +o +« 74 ve | sefiz | seme : = P3_TO IPS AND _JPO TO _JP12 OPTONS: Dene Rae re SSPE ee be Sr SEE SHEET 5 FOR FURTHER DETALS QL wv 1@ 7/AMO0175 ® vewonk so/ne so [Blalllely [| SER AL NTERFACE MODULE SWITCH SETTNGS TYP CAL SETTINGS ‘Sw2. ‘Sw Sw4 JP9 | JP10[ JP 1]UP 2)? SUP 41P SPE PTDP T: T]213]4]5! 11213] 4) 1121314 [1 105] Tosh /3n 74h 73h 7h 73h 73h 73h 7a ofofofofolol+fojtjolojols STSI3TST3 31313 SEE PRODUCT NSTRUCTON £93 905 FOR MORE NFORMATION ON NSMOI SEE PRODUCT NSTRUCTION £96-620 FOR MORE NFOMATON ON NSMO} NETWORK 90/NFI 90 AL76O273E SHT.5 0 ws CR Fie= geazs0s WN). Sued: a a OP _STCRAGE MODULE SWTCH SETTNGS THE LSMO1_S PART OF NCUO2, LSMO2 $ PART OF CUO3 pcrOY § PART GF PCO? ARs TO MEMORY CARD P4 NPCTOL NLSMCO cPu CARD TO MEMORY CARD PS [= | UOOUONUO (Ui000 NOTES 1 SWTCH SET "OPEN’ — 1 2 SWTCH U7S SELECTS PORT ADDRESS. POSN 5 S LEAST SGNF CANT 8T 3 Ji-2 3 SELECTS EPROM TYPE NSTALLED Ji—J2 - 27256 32-53 = 27128 4 SW TCH _U73 SELECTS TRANSM SSION RATES FOR TWO RS232 PORTS POS'N 1 TO 4 = TERMNAL PORT (POSNN 1 POS'N 5 TO 8 = PRINTER PORT (POS'N S _ AUD RATES: 5000 4 = 1 a= 75 5 = 300 $= 2 1i0_ 8 = 600 10 = 1345 7=12 = 5 SWTCH U72 SELECTS OPERATING OPTIONS: POLE 1 = ROM CHECKSUNMNM.NG, 1 = OFF, 0 = ON POLES 2 & 3 = PORT 0 & 1 DATA CHARACTER STCS 00 -8 BTS, 1 STOP ST, NO PARTY 01 -8 BITS, 1 STOP BIT, EVEN PARTY “0 8 BTS, * STOP B87, OOD PARTY 11 -8 BTS, 2 STOP BTS. POLE 4 = PORT 1 OPTION (1 = UTILITY/O = COMPUTER) POLE 5 = MODEM PASSWORD PROTECTON (1 = ON/O — OFF) POLE 6 = PORT ADDRESSING MODE (1 = CN/O = OFF) POLE 7 = CHECKSUMMING (1 = ON/O = OFF) POLE 8 = PRMARY/SECONDARY (DFFERENT BETWEEN REDUNDANT usm’s/ PCT's) ° 1 2 3 REFER TO PROGRAMME'S REFERENCE MANUAL E93-905-2 FOR FURTHER FORMATION ON NLSMOI_ NLSMO2 ‘SEE PRODUCT NSTRUCT ON E96-621 FOR MORE INFORMATION ON NPCTO! @® NETWORK. 80/NF_ 90 le |AL760273E SHT 6) Cad FLE= Jo027308_\N\, Ss nee 7/M100175, TRANSFER A INTERE TCH SETTINGS PART OF CIUOZ AND CUO3, PPGO! OR PPGO2, PCIO2, PPROT rr T2545 fe ti ad f a so 0000) NBTMOIA 23 OPEN NBTMO1 FIXED NTERNAL ADDRESS 2 Notes: 1 SWTCH SET OPEN = LOGC 1 2 SWI S NOT NORMALLY USED (D AGNOSTICS) au ENABLE/O SABLE STATUS ALARM (1-2=ENABL:, 2 3 D SABLE) 4/2 - NOT USED MODULE ‘Swi Jt aopress _[7]2]3]4]51 1/3 | 2 ofofofoto FLAT DMA CABLE (NBTMOTA/INBTMO1 TO NLMO2/NLIMO3 P4 CONNECTOR) 4 ps 1 Pom NL MO2 NLMO3, i 1 33 1 SWITCH OPEN = LOGIC 1 (POS 8 S THE LEAST SIGNF CANT BT) 2 Sw2 -3 TO 8 SELECTS PCU NODE ADORESS (0 — 63) OPEN ENABLES Um, TO. CONTNUE FUMING. 30 SECONDS "ABTER A OOUBLE LOOP FAULT OCCURS FOR TROUBLE SHOOTING PURPOSES ONLY SEE EN 6/0-NSO 2667 CLOSE - NORMAL OPERATION 3. Swi IS DAGNOSTIC/DISPLAY SWITCH 4 REFER To SHT 5 FOR STANDARD AIMPER SETTINGS (NOT APPUCAB.E TO NLMOS) Sw CALD sez Tz]3}413161 718] ]2]5] 415/611 fafoit {+0161 ro[o[o} [REFER TO PRODUCT INSTRUCTION £93-905~2 FOR FURTHER NFORWATION ON NBTMOIA/WL MG2 SEE PROOUCT NSTRUCTION £95 621 FOR MORE NFORMATION ON NBTMOI/NLMOS B AL760273F SHT. 7 ] NETWORK 90/NF $0 CAD FILES 76027307 \\\ Sn Wart (a AL7602730_SHT 8 CAD FLE~ 76027308, SER AL PORT MODULE SWITCH SETT NGS NSPMO1 MSPMOt NOTES 1 SWITCH SET OPEN ~ LOG¢ 1 2 SW2 SELECT ADDRESS (5-isB) 3 Sw3 SELECT PORT OPTONS AND Sw3 =e) ee 4, JPL ae JP2 SELECT ROM TYPES Fame Pe UB ger | RE REE Tr 72 eee T * +E5 +e +e 2 * vt | eRe | ee arf? | s+ +=] un cath wm OO a}rm OO 3] 200 OO sm OO sLixe 6 0 SEE SHEET 9 FOR FURTHER DETALS NETWORK 90/NF 90 NV Sys Meeks Es loo000| 00000] 7/A100175 SER AL PORT Moe SWITCH SETTNGS TYP CAL SETTINGS Sw2 SWS Swa [PS | JPi0] P| PaP SP PS Pepe PRIA EIEIEIEREEARICS 1705/3 TOSH/sh Jah 73h 73h 730 73h 7sh73\ iyo STsT313 1313 Is le a ie io io a SEE PRODUCT INSTRUCTION £93-305-1 FOR MORE NFORMATION ON NSPMOt SEE PRODUCT MSTRUCTON FOR MORE NFORMATON ON MSPMOi NETWORK 90/NF 90 7/AN00175 AL 7602730 SHT, 9 cad FLE- 76027309 WV Se \sccbeae T3 .cps NCTMO}} FR tases é& @ “tll NOTE 1) SWTCH OPEN = LOGC 1 (POS 5 S THE LEAST SGNFICANT BT) 2)SW2 S THE MODULE ADDRESS WHICH S NORMALLY SET TO 2 a ha 23 MODLUE Sw ADDRESS TT27T3sTe Ts — Tecan [o|o[o[1lo WUMPER TABLE POS TIONS CLOSED JUMPER | STD. (25L32) COMP. DES. ALT. (2532) ALT (2732) : I 2-3 1-2 Uae JP2 1-2 2-3 = PS 2-3 1-2 Pa 1-2 2-3 uae PS 1-2 1-2 Wai, 022 7/N100175 NETWORK 90/NF 90 }AL760273C SHT.10 7 {can rie Fe62710 Spork TR RM SW TCH SETTNGS wren omen = 00 + & tesase ws sS(Q00000] aur 2 NCOMO2/03/04 7 2B woncar/oz assure + a3es6 2 / MGRCO}/02 (00000000) = sAQDOD0O] ors ; ss OPEN NOTES 1) SWTCH OPEN - LOGC 1 2)S4 ADDRESS SWITCH (POS TION 8 S LEAST SGNIF CANT) $4-1 TO S4—3 SELF TEST — NORMALLY CLOSED S4—4 TO S4-8 ADDRESS (0-31) 3)S2 AND S3 ANALOG OUPUT CONFIGURATION S2-OLTPUT #1 S3-OJTPUT 42 OPEN 5.25V ON POWER-UP SLOSED 0 75V ON POWER-UP 2 OPEN AND 3 CLOSED HOLD LAST VALUE 2 CLOSED AND 3 OPEN POWER UP SETTING 4 AND 6 CLOSED AND 5 OPEN vOLTAGE OUTPUT 4 AND 6 OPEN AND 5 CLOSED CURRENT OUTPUT USER MUST VERIFY THAT SWITCHES S2 & S3 ARE PROPERLY SET UP FCR CURRENT/VOLTAGE ALONG WITH TU DPSHUNT CONFIGURATION PRIOR TO POWER UP, OTHERWISE POSS BLE DAMAGE TO MODULE COULD OCCUR. FOR NON-CONF GURED SYSTEMS ENSURE THAT S2 & S3 ARE ALL OPEN 4) Jt, 2, JB SELECT DGITAL NPUT VOLTAGE (1-2=24V0C, 2 3-125vDC) 4 32 s3 wt [2] 5 i[2Tsl4[slej7tels [27s]4[sfels [2134 [sis h7ah/si7a) ofofo FOR FURTHER INFORMATION ON NCOMOZ/03/04 SEE PRODUCT NSTRUCTION £95-S06-« FOR FURTHER INFORMATION ON NORCO! SEE PRODUCT NSTRUCTON E63 905-3 FOR MORE NFORWATION ON MCOMO3/04, MORCO!/02 SEE PROOUCT NSTRUCTION £96 207 7/1001 75 NETWORK 90/NF 90 AL760273E SHT._11 Gad FILE 7602731 W\ Scion > R_MODU SWITCH SETTNGS TYPE NCOMO2/03/04 12345 1234 Sw2 { q 1 Ts NCOMO2/03/04 ‘OPEN 12345678 us] 20000000 09900000 3 3 fH te FP sane v205 93 ob 33 ust ave spatter 3] 4 [ { SWITCH OPEV = LOGC 1 Sw2 Ig SET 10 THE MODULE ADDRESS (0 THRU 31) W3—3 SELECTS POWER-UP OPTION Fo! 1B 4 ARE NORMALLY CLOSED 2 3 SELECTS TYBE OF AOR! (O10 = CURRENT 101 = VOLTAGE) & 3 Steers ee Oe acl (oro = Gunwenr ‘dr = VaLtace) UAL eevee ran OP ON at POS. 5S THE LEAST SGNF CANT 8) ‘AoW! (O=0R, 1=100%) 3 70 HOD. ao [ro poweR=Ue To [1 BO, 2 3 SELECT O1G TAL NPUT VOLTAGE, (1, = 24VEC, 3 = 32540C) 20E SELECTS THE-OUT OPTION FOR ADE (1 = HOLD, 3 = POWER-UP) W205 SELECTS POWER—UP OPTION FOR AD#2 (1 1S USED 70 ZERO MEMORY REFER TO PRODUCT NSTRUCTON E93-906-2 FOR FURTHER NFORMATION AL760273C SHT 12 [CAD FILE 76027312 (ss \sooke = 109%, 3 = 0%) network 90/nF so |B, T/A100175 2G TAL CONTROL SWITCH SETTNGS BYPASS 7 orn xu18 v 1a rs LI 1H ves oT -23 iH} re Nocsos op 5 Eos Hs wi { \ Ae FY ies NOTE 1 SWITCH OPEN — LOGIC 1 (POS 3S THE LEAST SGNF CANT 87) 2SW1 S SET TO THE STATON ADDRESS (0 TO 7) 3BY-PASS CARD — XUI6 DPSHUNT (SEE BELOW) vt AND J2 NORMALLY (1-2) 4 JP1 TO UPS SELECT OPTONS PER TABLE 5 uP3 SELECTS VALUE TO BE DSPLAYED ON OUTPUT METER DUR NG NORMAL OPERATION 6 JP4 SELECTS ON WHICH METER THE ANALOG NPUT IS D PLAYED DUR NG_SYPASS. WUMPER [SELECT] OPTON = ‘AUTO _BYPASS ay 2-3 CANCEL AUTO BYPASS 1-2 REVERSE ACT NG ets 2-3 CANCEL REVERS ACTNG. 1=2 ‘COM OUTPUT 1D SPLAYED. WPS 2-3_| ANALOG NBUT DsPLaveD (SEE NOTE 5) 7=2 "ANALOG INPUT DiSPLAYED ON CO SCALE uP 223 _| ANALOG INPUT DISPLAYED ON BV Scate (SEE NOTE 6) e 1-2 ER GHT NIENSITY SELECTED oP 2-3__|_CM_NTENSITY SELECTED, XU16— FOR ANALOG SGNALS ONLY (£ DCSO3_$ USED FOR ORIVER REFER TO INSTRUCTON 300«) INTERNAL EXTERNAL ANALOG "ANALOG SIGNAL SIGNAL’ NOTE 39 oo] XB ON TU. TYRE NTCSOO 8-9] ust ALSO SE CONF CURED N os SS] CON NCTION WH THs, 808 © S| (REFER DL7E0010) 85 88 ca o8 S33 3 REFER JQ PRODUCT NSTRUCTION E93-S02—1 FOR FURTHER 5 REEMA? oe nerwoak co /me so [BAlilley| 7/M100175 AL760273C SHT 13. } GAO FLE~ 7e027H3 W\. Se\ecoke - PLANT LOOP /SUFER LOOP/ NF —NET TERMNATON UNT NTCLO1 te (663699701) NOTES 1 THERE ARE TWO VERSONS OF NTCLON's PLEASE NC E ASSEMBLY NUMBER TO DETERMNE VERS ON SEE_SHEET 63 FOR _NFORMATONON 66369971 (APPROX MATE DATE OF BOARD CHANGE S NOV 1990) 2 Ji TO vd ARE BNC CONNECTORS FOR COAX CABLES. I= LOOP TN, J4 — LOOP 2 N v2 = LOIP 1 OUT «3. = LOOP 2 OUT 3 JS - JI2 SELECTS MODULE TYPE (LM OR LS/NS) 1 2) LM & 3) = LS/Ns 4.y13 TO JIB SELECTS CABLE TYPE (TWNAX OR COAX) ("= 2) = Twinae (2 - 3) = Coax SEE PPODUCT NSTPUCTIONS £93 911 FOR MORE NFORMATON ®O® NETWORK 90/NF go Gad PLEX HeaadSe NX Selene T/NO0175, DGTAI ATNG STATON SW TCH TENG: \D sor NOTES. 1 SWTCH SET OPEN = LOGC 1 2S! SELECTS ADDRESS (2 = LSB) STATON ADDRESS Si si-2 8 ° ° 9 ° 1 10 1 ° " 1 1 3. JP1 SELECT DISPLAY NTENSITY 1 = BRIGHT D SPLAY 3 = DM OSPLAY REFER TO PRODUCT INSTRUCTION E93~904—2 FOR FURTHER NFORMAT ON. [o|® i T/A100175 NETWORK 90/NF SO |AL760273C SHT.15 cad FE 7e08755 {\\ clout « ANA MASTER M SW TCH SETTNGS — Pe PS 5 | NAMMO2 MOTHER: | BOARD 12 7 effi | | NOTES 1) SWTCH OPEN - LOGC 1 (POS 5 S THE LEAST SGNF CANT 87) 2)S101 5 SET TO THE MODULE ADDRESS (3 TO 31) NAMMO2 | MASTER ANALOG 7 BOARD sw l NOTES 1) SWTCH OPEN = LOGC 1 (POS 5 S THE LEAST SGNF CANT 61) 2)SW1 ON "ANALOG BOARD” SET FOR EAROM NTALZE MODE NTALZE DARL CONF G_EAROM ofofol1{o CALS EAROM ofofoy its ofolifoyo | | BOTH EAROMS | REFER TO PRODUCT NSTRUCTION €93-912-2 FOR FURTHER NFORMAT ON network so/ne 90 [B. T/MO00175 AN OPES Sore WV Sclvcokk eee SS) 18 NaSMoS WasMo! =5 hm = a 15 18 NOTES: 1) SWITCH OPEN LOGIC 1 (POS 3 S THE LEAST SGNF CANT BT) 2) JPi SELECTS GROUP A, JP2 GROUP B (A—D SABLE, B=ENABLE) 3) 51S SET TO GROUP & ADDRESS, SZ TO GROUP A ADORESS REFER TO PRODUCT NSTRUCTION £93~912~4 FOR FURTHER INFORMATION ON NASMOt REFER To PRODUCT INSTRUCTION E96-205 FOR FUTHER NFORWATION ON MASMO! NETWORK 90/NF 90 AL7602730 SHT.17_ ow CAD _FLE— 76027317 7/A100175 LOW LEVEL ANALOG SLAVE MODULES SW TCH SETTNGS SLAVE, NASMO2/03/04 MASMO2/03/04 NOTES, 1) SWITCH OPEN = LOGC 1 (POS 3 S THE LEAST SGNF CANT 87) 2)S1 $ SET TO SLAVE ADORESS (0 TO 7) | ~ TABLE 1 NOMENCLATURE | __DESCRPTION [PRODUCT _NSTRUCTON # NASMOZ_— | THERWOCOUPLE /mvOLT €93-912-5, NASMO3___[100 ARTO €93-9 2-6 NasMos [10 @_RTO €93—9 2-7 MaswO2 | THERMOCOUPLE /mVOLT £9520 MASMOS [100 RTD = 208 ‘MASMO4 70 ARTO E96-205 NETWORK 80/NF_ $0 AL760275€ SHT.18 = GAD FLE= 7602788 _\\\ Sr \vcoker - ANALOG OUTPUT M £233 teas Maomor | E16 soll IE] waomor | *'82 oe >o 0008 NOTES. 1) SWTCH OPEN = LOGC 1 (POS 5 S THE LEAST SGNF CANT BT) SWITCH SETINGS ANMAAMmE 2BET8 00000000, 000000009 00000000 2) SWI S SET TO THE MODULE ADDRESS (0 To 31) 3)E3_S THE VOLTAGE RANGE (A ~ 1 5V/4 20mA, 8 ~ 0-10V) S)F6—FI3 SETS THE TYPE OF OUTPUT (A = VOITAGE, 8 = CURRENT) | MEMORY et AND TYPE USED] £2 2532 Das 25.32 2&3 12732 1&2) 190401 2&3 REFER TO PROOUCT INSTRUCT ON £93-S12~3 FOR FURTHER NFORMATON ON NAOMO1 REFER TO PRODUCT NSTRUCTION £96-206 FOR FUTHER NFORMATION ON MAOMOT |AL760273D SHT 19 da ee roo27s9 WN \. RAneee NETWORK 90/NF 90 4 Pia|® [| ee T/N00175 MMFCOS AB MMpCot 70 MOWORY CARD PA NMECOI ee NMFCO2 peer NMFCO3 NMPcOr CPU CARD 172 4 1 RB gs favpoGoon) (ouoooeo 0) me 1g} (ono NOTE. SLAVE ADORESS 0 HAS LOWEST PROR IY (AND 53 HGHEST) RELATVE TO SLAVE NTERRUPTS TO MFC 1 SWTCH SET “OPENT = 060 1 2 SNITCH U7S SELECTS MODULE ADORESS (POS TION S = LSB) NOTE. REDUNDANT WFC APPL CATONS USE SAME ADDRESS. 3 vt 2-3 SELECTS EPROM TYPE NSTALLED Siw 2 = 77236 2 = M3 = 27128 4 SMTCH U73 SELECTS TRANSMISSION RATES FOR TWO RS2S2 PORTS POSN 110 4= TERNAL PORT (POS'N 1 = LSB) POSN TO 8 = PRNTER PORT (POSN 5 = LSB) BAUD RATES. o= 50 42 150 eK 12 = 40K 1273 S300 o= 2K 35 = 72K 2-10 6 = 600 = 24 34 2 98k Bees | 7a 12K me 36K 1s = 192« 5 SWITCH U72 SELECTS OPERATING OPTIONS. POSN 1 = SPECAL OPERATIONS SWTCH — NORMALLY SET CLOSED 13 4 OPEN = ‘SUPERLOG MODE LUS TIME STAMPING 1&4 OPIN = SUPERLOGR MODE 1&3 OPN = PLANTLOOP MODE + 1+ THS SWITCH SETTING § USED TO NTIALIZE NVRAM CONF GURATION SPACI SPECAL NTALZATON PROCEDURES FOR NWFCOS. ‘ONLY REDU RED ONCE ONLY (ALL OTHER POLES MUST BE CLOSED ) E “HS ENABLES "HE MODES 70 RECOVER FROM SOME ERROR MODES (MFCOS Ov”) 2 = ONCLNE CONFIGURATON = OPEN 5 2 Ghat oma CHECK = OPEN 2 2 hatB Row CHECKGUEWORY) = OPEN or 5 1 hier Row cneoxccru) = & 7 coupAct NvRaw FREE SPACE tom | cox $2 wnauze nwa = on 2 rN AsTeR/Suave MFC (OPEN — SLAVE) os 7 TEs TBSP EDET TI a) B REFER TO PRODUCT NSTRUCTION E93~906—1 FOR FURTHER NFCRMATION ON NuFco REFER TO TECHN CAL OVERVIEW FOR FURTHER INFORMATION ON NMPCOI REFER TO PRODUCT NSTRUCTION REFER TO PRODUCT NSTRUCTION \\\ |AL760273K SHT.20 CAD FLE- 76027320 FOR MORE NFORMATION ON MMFCOS FOR’ MORE "NFORMATION ON IMMECOX 3|2 = NETWORK $0/NF 93 Sa iad 7/AN00175, CONTRO! /O_ SLAVE MODULE SWTCH SETTNGS 455 iz s2[QOD000]}o7 2 OREN Reco: s: [D00000]ou" » ee = 123456 iasase s\ (000000 oo0000 a | OFEN 1 SWITCH SET OPEN ~ LOGC 1 281 - 1 SELECTS D NO.1 VOLTAGE } OPEN = 125vDC CLOSED -"24VDC Si - 3 SELECTS 0 NO2 VOLTAGE St - 5 SELECTS D. NO3 VOLTAGE Ss 2, 4 AND 6 ARE UNUSED 3S ANALOG OUTPUT O>TONS (S2 - AO NO 2, S3 AO NO 1) POS'N 1 -3 — CURRENT - 101 VOLTAGE =010 POSN 4 = SLAVE FAULT DEFAULT VALUE (=LOSED = 0% OPEN = 100%) POS'IN S TME-OUT OPTON (OPEN = HOLD, CLOSED - POWER—UP) POSN 6 = POWER-UP STATE (OPEN - 100% CLOSED ~ 0%) 4.54 S SLAVE ADDRESS (POS'N 6 - LSB) POS TIONS swrch | usace [1 [2[3]4]5 [6 31 OF ROE Save USE-ONLY ADORE S¢ | ADDRESS nore: SAE RSS REFER TO PRODUCT NSTRUCTION E93~913-9 FOR FURTHER NFORMATON @@® network 20/ nF so [BiAlillle! T/A100175, AL7602736 SHT.21 cad FLE~ 76027321 _\\\ S\ncetie MLMMO2 iii SWITCH SET OPEN = LOGC 1 2 S2-4 TO 8 S MODULE ADDRESS (POS 8 S LEAST SGNF CANT BT) 3 $2-1 TO 3 S MODULE SELF TESTS NORMALLY ALL SET CLOSED 4 $2-2 OPEN NTALZES NVRAM. $2 2 AND S2-3 OPEN COMPRESSES NVRAM — 5 JUMPERS J1 TO JB SELECT DIG TAL NPUT VOLTAGE: 1-2 = 125vDC/120VAC 2-3 = 24V0C 32 PISASE REINS) 4][5[6]7 18 VA AL760273E SHT 22 ~ CAD FILE~ 76027322 _\N\. Tkvcchs ¢ REFER TO PRODUCT NSTRUCTION £93-907-5 FOR FURTHER NFORMATION ON NUMMOZ REFER TO PRODUCT NSTRUCTION FOR FURTHER NFORMATION ON MLMMO2 NETWORK 90/NF 90 7/A100175, CONTACT _NPUT SLAVE MODULE SW TCH SETT NG! iP. 2,208, | jo 3883 geese T3338 5888855 a VRB 3538 33.33.85 \psvo3 $282 wae ae we 8888 123 oP Poh ene 3533383 | sf 83° 51°39 0g) 5 : TE open NOlglatcn seT OPEN = LOGC 1 2 Ji TO JI6 SELECTS PONT RESPONSE TME: 1- 2= DC SLOW 2 3 = D.C FAST 3 4= AC C: 3. y'7 SELECTS SLAVE USAGE: 2 = 3 LMMat fora (701) 4 yI8 TO J33 SELECTS PONT VOLTAGE 1 - 2 = 24vDC 2 3 = 125v0C/120VAC 5. Sl SELECTS SLAVE ADRRESS | ATF LMMO1/O1A — GROUP 7A” = POSIN1 — 4 (4 = LSB, GROUP "BY = POSN 5 — 8 (8 = LSB B F MFC/LMMO2 — USE POS'N 3 TO 8 6 S2 SELECTS GROUP ENABLE~ A IF LMMOT/O1A POS'N 1= GROUP a 8. F MFC/LUMOZPOSN {= NOT USED fEnae = 8. F-MFC/LUMOZPOSN f= NOT U' POS'N 2— OPEN eee REFER TO PRODUCT NSTRUCTON £93-913-5 FOR FURTHER RE OmmaTiON NETWORK 90/NF 90 3|® o fee T/M00175 AL760273C SHT. 23 Gad FILE 76027323 \\\> Se-\n cote ¢ PULSE NPUT SLAVE MODULE Ns2 Our PREANe an ss out va Ee] C NOSMO4 MOSMOs 1 SWITCH SET OPEN - LOGC 1 281 SELECTS SLAVE ADDRESS. 6 — LSB (USE ONLY ADDRESS 0 TO 63) 3S2—N =ROUES CHANNEL * NPUTS TAROUGn PRE-AMP ~OUT = CHANNEL 1 NPUTS BYPASS PRE—AMP 4S3.—N = ROUTES CHANNEL 2 NPUTS THROUGH PREAMP OUT = CHANNEL 2 NPUTS BYPASS PRE-AMo 5 Jt TO J8 SELECT VOLTAGE RANGE FOR NPUTS.(CH 1 TO B RESPECT VELY) A=lLOGCO=OT01 WC Loci 41 6 cc B - LOGC 0 = 0 102 WC LOGC 1 = 216 TO 27 woe 6 J9 TO J16 SELECT DEBOUNCE FOR NPUTS(CH.1 70 8 RESPECT VELY) © =NO DEBOUNCE D = & SmSEC RESPONCE OELAY REFER TO PRODUCT NSTRUCTION E93-913-6 FOR FURTHER NFORMATION ON NOSMO4 REFER 10 PRODUCT INSTRUCTION E95~308 FOR FUTHER NFORMATION ON MOSMC NETWORK 90/NF 90 }AL7602730 SHT. 24 GAD FLE~ 76027304 W\ Relate 7/a100175, OGTAL SLAVE MODULE SWTCH SETTNGS an Be USS ofev00] | (OUGUNOO FF HB age Bs NOSMOS eh Bx wosMos 3B 3B a 3Bne 39 ao 7 i 7 erage | eg gy omMONTG) GaNNATTD Bede ‘NOTES. 1 Son! ST STS aE 2.4 TO 16 SELECT TYPE OF SGNAL (3 = SOLATED OUTPUT, 1 = OTHER) Slav a sta stuccr nIEwACE NPE (0 = cuter/o\e 9 = WFP/ uroAANEA} dar sacs persct vues rom enue “a rons S SESS SEPA! VUES FOR SMES SOR oe oe mens re TS oaneeD 88 + scers /o noe ron cums rons } = we wo 31 EGS 70 Tie Oe Seaver pong Oper 1 = over 3 3 Seer fe wotute nantton Go we 1 = para uace sranow) @ SS mew str wo Berane «0 See mate 5) So eater te 70 Saar ae reese ese OUTPUTS) 6 s+ mers wopwe soneess SE a Raw 1 ro 4 = one 0 (= us) oer ye) 8 F urcAureAuionese POSNSTO Bee La) 3 5 Ainvans Gaur 3: ony $e = Ome Fon umuo2/MFC/urr 59-2 ACINATES AL PONTE REFER TO PRODUCT NSTRUCTION E95-915-7 FOR FURTHER NFORMATION ON NOSMOS REFER “O PRCOUC™ NSTRUCTON £96—309 FOR FL"MER NFORMATON ON MOSMOS @® network 90/nF 90 (BI } a [@| Ke AL760273" SHT, 25 GAD FILE~ 76027325 \\\, Se\n pete T{M00175 GTAI NPUT MOD WICH SETT NGS NDS 01 notes. 1 SWTCH SET OPEN = LOGC 1 2 S1 SELECTS SLAVE /GROUP_ADDORESSES. FOR LMMOI/O1A S1-1 TO Si-4 — GROUP A ADDRESS (4-LSB) 51-5 TO Si 8 = GROUP & ADDR?SS (8=LS8) FOR LMMO2/MFC Si-1 AND $i 2 MUST BE CLOSED S1-3 TO Si-8 = SLAVE ADDRESS (8=LS8) = 3 JI8 TO 33 SELECTS NPUT VOLTAGE LEVEL (3 128vDC, 120vAC_ 1 - 24v0C) 4 NDSO} MUST HAVE PGGY BACK BOARD NSTALI WHEN WORKING WTH AN NLMMOT OR NLMMOIA\ (KT 4258355) REFER TO PRODUCT NSTRUCTION £93-913-15 FOR FURTHER NFORMAT ON 2 @@s eee verwone so/ne oo Bille CAD FLE- 76027326 \\\. Sel kes | re) DGTAL SLAVE OUTPUT MODULE SWITCH SETT NG: MODULE OUTPUT TYPE DS5001 | 4VAC_240VA ‘Ds002_| 4vDe_SOvDC ‘S003 | 5vDC_160vDC NDSOOt /02/03 MDso01 /09/0% we OPEN NOTES. 1 SWITCH SET OPEN ~ LOGC 1 2 $1 SELECT ADDRESS 6 LSB (ADDRESS 0 TO 63 ONLY) 3 Fi TO FB FOR DSO0" - 40 AMP NORMAL (WAS 7 AMP SLOW BLOW) FOR DSO02 ~ 30 AMP NORMAL (WAS 4 AMP NORMAL) FOR DSOO3. 15 AMP NORMAL MODULE OUTPUT TYPE. Ds004 ZaOC npsoo4 M0SO04 1 8 0000000 ‘OPEN Notes, 1 SWITCH SET OPEN = LOGC I 2 S1 SELECT ADDRESS, 8 — LSB (ADDRESS 0 TO 63 ONLY) REFER TO PRODUCT INSTRUCT ON £93~G15-10 FOR FURTHER INFORMATION ON NOSOO1 /02/03/04 REFER “0 PRODUC~ NE-RUCION E96=310 FOR FUTHER MFORMATON ON MOSOO-/02/03 REFER TO PRODUCT NSTRUGTION E96 313 FOR FUTHER NFORMATION ON WOSOOS @@s iS |AL760273F SHT. 27 = NETWORK 90/KF 90 = CAO FLE~ 76027327 A a I~ — TA\ TATON SWITCH SETTN 3 { | = = | 2 =) | novso2 310 st SS 1 S 23 = = NOTE 1} SWTCH OPEN = Log. 1 (POS 3. S THE eS SGNF CANT 81) ! QSL S Set TO THE STATON ADRESS (0 70 { (3)S9_& S10 SELECTS NTENS TY DEPEND NG ON oor LEO'S NSTALLEO OPEN=RED/YELLOW CLOSED=GREEN $9 POS 1 — CR2 S10 POS 1 - CRIO 2- CRS 2- CRI 3 - CR4 3 - CRI2 ~ 4 - CRS 4 CRIS 5 - CRE 5 - cRié 6 - cR7 6 CRIS {i — cre 7 = CRIB cRo 8 CRIT 4)LED S ARE RED ON STANDARD MODULE GED'S MUST BE CHANGE TO OBTAN OTHER COLORS. REFER TO PRODUCT NSTRUCTONS £93-904—1 FOR FUTHER NFORMATION @ © ALT60273C SHT 28 NETWORK 90/NF 90 ~ CAD FLE— 76027328 Ws acoker T/A100175, f LOOP COMMAND CONTROLLER SWTCH SETTNGS Pt (OPERATOR NTERFACE BOARD Poa aT i AL780273C SHT. 29 CAD FILE—" 76027329 NOTES: 1 R100 ADJUSTS BARGRAPH NTENS TY (ADJUST N PCWER-UP COND TON) DECREASE INTENSITY NCREASE NTENS TY — ADJUST COUNTERCLOCKW SE 2 Swi OPTONS ADJUST CLOCKWISE, 92 23) orn ‘erm oesaRPTON ae aoe wT 7 SnD [pa a = eS Pes ec Ely w wana Soca Janke NeuT TaKoe rmow anaccc Saroae oe sicarate pone ive. Ovean OE MSDE ene iat 3 on Tee TeRuATON [pearo Ws? ALSO Be Se7) SEE DWG ALI0S033 SHT 30 FOR MORE DETALS. REFER TO PRODUCT NSTRUCTON £92-500-1 FOR FURTHER NFORMATON. NETWORK 90/NF 90 Qsedcccee c 7/M00175, MMA NIROLLER SWITCH SETTNGS (OPERATOR NTERFACE BOARD) NOTES: (cow) 4 sw2 oProns om aaa aaa ar Oe oe eee FO RA ST OSU eat gy [ne omar onus gr oer Tae |e Sn eae on no Nc, be eet omy larpeueas emer Ta ia — Tacos ae ovo | cr ao ge era TERS ane RE eee om | edt STS TS a Reariane Peat ce es Seka Sia ae sre {io noe some ao aa BT ae See ar core [ape nom amnonon SEE SHEET 31 FOR FURTHER DETALS. REFER TO PRODUCT NSTRUCTON £92~S00-1 FOR FURTHER NFORMATON AL7602730 SHT 30 = [CAD FILE 76027330 \\\s Sch cet :— NETWORK 90/NF 90 Bailey @@ 7/a100175' OP MMAN. NTR! R SWITCH SETTNGS 123tb678 (MAN BOARD) saslers cugos Pagans (00000000) C.CO3 a Slee NOTES 1 SWTCH OPEV - LOGC 1 2 S2 - 4 TO 6 SELECTS ADDRESS (8 = LSB) $2 - 1 ~ CLOSED = NORMAL OPERATION OPEN — FACTORY TEST ENABLED $2.2 OPEN = NVRAM NTAUZED CLOSED = NORMAL OPERATION S23 OPEN. = GENERAL PURPOSE SWITCH (H GH) CLOSED = GENERAL PURPOSE SwiCH (LOW) (REFERENCE EXECUT VE BLOCK 242 AND FUIICTON CODE 53_N FUNCTION CODE MANUAL E93-900-20 3.1 ANALCG OUTPUT OPTIONS oe aaa one ‘sere DESERPTION ae on mcouT GOES TO PoweR-U VALE SET BY ar Tet SEY Sr roe eater ue omer vue er ican | tose ‘cose ‘Oren ‘Fo | VaLOS Sav OUTBUT FOR POwa OF cioseo Po closeo ose SEE SHEET 32 FOR FURTHER DETALS NETWORK 90/KF 90 |AL760273F SHT. 31 = ICAO FILE— 76037331 \V Txlarote REFER TO PRODUCT NSTRUCTON £92-500-1 FOR FURTHER NFORMATON@)(@): 7/M00175, Pailley, MM AN, INTROLLER SW TCH. TTN (TERMINATION BOARD) Bt mez 8 ] 2B “=| acor $2 cLCO2 “EE cucos -|S} 04 pa cu 13 ~ NOTES: 1 SWTCH OPEN = LOGC 1 2 $2 OPTONS ‘orn SEIN ‘DESCRETION ae RS es |e ocr nwur aaa _opew |r ror oxarea nur Rez eed | SE Fon ROCA veut para veur [mos _groe, far ron uae a SEE DWG. AL105033 SHT 33 FOR MORE DETALS. REFER TO PRODUCT NSTRUCTION £92-500-1 FOR FURTHER NFORMATION a 3 AL760273D SHT. 32 ne TWORE: 007 NES 90) S = CAD FILE— 76027332 a LOOP MMAND. NTR: SWITCH TT NGS (TERM NATION BOARD) NOTES (CON'T) 3 S1 OPTIONS orTEN serve ‘DESCRIPTOR ae RAIDS WATT Nat [SOOPER TTR VaR WOT lost Fon Connent NUT ckosto FoR Coenen NUT Talos BRIT Was [m8 or koto Toe ene waar FOR coment Neu TAGE RAT nae [7 SP bso To eee teoT Fon Chor Neu SATE TRACE | =e OPEN Soren |S BSE oR AE ua Sotaaton areesace soun) ane Raga wut eds Neveatvaten Sout Riadbo wor ness seat SORT oT [aioe = oe Ssuarernon [Ses See aT Sareea DePtAy cpmeN oF A seconoARy Sar bean ttos ae RATES OUTPUT wat | =F OPER ruioe OUmPUT Ma2|si-1 opp Tor CoRReRT OoeUT Fon Yarra Suieut ron cunmext ourvur Foe Settaae Sutra + SEE ANALOG NPUT DISPLAY OPTION ON SHEET 29 FOR ADD TONAL SWITCH SETTINGS ON THE NTERFACE BOARD + SEE SHEETS 13 AND 14 FOR ADD TONAL SWITCH SETTINGS ON THE NDCSOS. REFER TO PRODUCT INSTRUCT ON £92~500-1 FOR FURTHER NFORMATION AL 760273" SHT.33 5 CAD FILE~ 76027333 \\\. Gc\nedkee NETWORK 90/NF 90 }@) wD hee 1 8 ooo00000) FEN NeIsoz 5 NORSO2 pees s21000000) IMQRSO2 1 SWTCH SET OPEN - LOGC 1 2 S1-3 TO 8 SELECT ADDRESS (POS'N 8 - LSB) 3 Si - 1 AND 2 NOT USED 4 $2 — 1 AND 4 NOT USED 5 ANALOG OUTPUT OPTIONS con cd eee | ey czevOeTace esecurmaer ExRoRE SEE DWG AL760273 SHT. 35 FOR MORE DETALS. 1AL7602730 SHT.34 NETWORK 90/INFi 90 Gap ries soorrsse \\\. SCA eo CONTROL 70 SLAVE MODULE SWICH SETTNGS QUCK RESFONSE CONTROL /O SLAVE SWITCH SETTNGS T/A100175 aaa CONTROL /O SLAVE MODULE SWTCH SETTNGS 5 DGTAL NPUT OPTONS OPTIONS |JUMPER|120VAC |125VDC SLOW 125VDC FAST| 2¢VOC SLOW |24vDC FAST DGITAL Jt ee 2-3 2-3 34 3-4 wi Je 1-2 2-3 3-4 2-3 3-4 OGTAL J2 aoe 2-3 2-3 34 3-4 2 8. 2 23 3a4 2-3 34 OGTAL J 1-2 2-3 2-3 3-4 34 “3 Tos [re 2-3 3o4 2-3 3¢ | 6. .7 S$ FACTORY SET AND SHOULD NOT BE CHANGED BY LISFR MUST ALWAYS 82 NSTALLEO POS TONS eS USAGE | _SwiTcH [RBEBED ERR A RavivcL see] SLAVE ADO St T ANALOG 52 OPTONS 1 FOR NCSO2 REFER TO PRODUCT INSTRUCTION E93 913 16 FOR FURTHER INFORMATION FOR NORSO2 REFER TO PRODUCT INSTRUCTION E93-S15 1¢ FOR FURTHER INFORMATION FOR MCISO2 REFER TO PRODUCT NSTRUCTON £96-—306 FOR FURTHER NFORMATON FOR MORSO2 REFER TO PRODUCT NSTRUCTON E96~316 FOR FUTHER NFORMATON ©® AL760273F SHT. 35 CAD FILE “76027338 DO Sc\wle NETWORK 90/N- 90 Z/aioot/5, ANALOG NPUT SLAVE MODULE SWITCH SETTNGS NAS O1 Naso2 “1 2sesera msca LOUD OPEN NOTES. 1 SWITCH SET OPEN LOGC 1 2 S1 SELECTS ADDRESS, 8=LS8 (ADDRESS 0 TO 63 ONLY) 3 Ji ALLOWS THE NSTTOI\NSTTO2 TO CONNECT TO THE SLAVE REFER TO PRODUCT NSTRUCTION E93-912-9 FOR FURTHER NFORMATION ON NAS 02 REFER TO PRODUCT NSTRUCTION 96-304 FOR FUTHER INFORMATION ON MAS 02 NETWORK 80/NF 90 AL7602730 _ SHT 36 CAD Pie 76027336 WV: scl, eke @@3 8/A0t nat) eae ANALOG MASTER MODULE SWITCH SETTINGS NAMMOS 12 NAMMO2A 1 j MAMMO3 i. ‘OPEN 1 SWITCH SET OPEN ~ LOGC 1 2 52 — ADDRESS AND DAGNOSTC SWTCH (S-LSB) SwicH $2 (Pore Ti [2]3]4[s 16] 716 DESCRPT ON O[OlO) MOOULE [NORMAL ofops] ADDRESS |conF GURATON Lock of1}o N TIAL ZE NVRAM ola}t NH®T CHECKSUMS tJofo PR MARY tot PRMARY & CONFG LOCK hilo UNUSED TP Tk x XX X[DAG.OSTE MODE REFER TO PRODUCT INSTRUCTION E93-912-8 FOR FURTHER NFORMATION ON NAMMOS REFER TO PRODUCT NSTRUCTION E96~205 FOR FUTHER NFORMATION ON VAMOS: NETWORK 90/N- 90 AL760273€ SHT. 57 CAD FLE— 76027337 _\\ 8/A00542 MULTFUNCT ON CONTROLLER MODULE SWITCH SETT NGS a L2sese7e z 2B BBS DUA0DOLN a | Nwecos os NOTEEy TCH SET OPEN = Loge 3 2 SMTCH SW3 — 4 To 8 SELECTS MODULE ADDRESS (8-158) SW3 — 1 MUST BE OPEN FOR PROPER MODULE OPERATION SW3 — 2 CLOSED FOR NORMAL OPERATON OPEN FOR D AGNOSTIC MODE Sw3 = 3 NOT USED 5 SMTCH SW4 SELECTS OPERATING OPTONS POSN t= SPECAL OPERATIONS SWTCH - NORMALLY SET CLOSED 13 & 4 OPEN = SUPERLOOP MODE SPEC AL NT ALZATON PLUS TIME STAMPING | pROCEDURES REQU RED 1 & 4 OPEN = SUPERLOOP MODE ONCE ONLY (ALL OTHER 1&3 OPEN = PLANTLOOP MODE * _) POLES MUST 8E CLOSED) = THS SWITCH SETTING _S USED TO NTIALZE NVRAM CONF GURATON SPACE THS ENABLES THE MODULE TO RECOVER FROM SOME ERROR MODES: ‘ON-LINE CONF GURATION = OPEN NHBT NVRAM CHECK “= OPEN NHBT EPROM (U39) CHECK = OPEN NORMALLY INH BT EPROM (U40) CHECK = OPEN SET COMPACT NVRAM FREE SPACE = OPEN CLOSED NTIALZE NVRAM = OPEN CLOSED = PRIMARY MFC OPEN “= SECONDARY MFC 4 J1_TO J18 NOT USED BY MFCO4. FACTORY SET TO 3-4 5 N17 TO 22 FACTORY SET TO 1-2. (MUST REMAIN AT 1 2 FOR PROPER MODULE OPERATION’ 6 J23 AND J24 RESERVED FOR FUTURE USE ‘SWS Sw4 OMPERS TT2]3]4 [5161718] 1121314 [51S] 7 8 brmae [uv7—scalias—i2) rlolx oO] forofofofol [a+ [sz | x REFER TO PRODUCT NSTRUCTON £95-906-12 FOR FURTHER NFORMAT ON ON NMFCOS REFER TO PRODUCT NSTRUCTION FOR FURTHER NFORMATON ON MMFCOS @@8 S| oNouAuN tonnnne 8 NETWORK 90/NF 90 eye |AL760273€ SHT.38 . S CAD FILE 76027338 \N\. Sc\. cle ¢ sae es MULTFUNCT ON CONTROLLER MODULE SWICH SETTNGS | NMFCOS OFF oF MMFCOS NOTES Tso ser OPEN Lose 4 | 2 SWITCH SW3 4 TO_& SELECTS MODULE ADDRESS (8-LS3) Sw3 1 MUST _BE_OPEN FOR PROPER MODULE OPERATION } ANS ~ 3 WiSces" Be Non Seeks MS OPEN FOR DACNOST.C MODE ays = 3 oT USS 3 SWITCH SW4 SELECTS OPERATING OPT ONS f POS'N 1 - SPEC AL OPERATIONS SWITCH ~ NORMALLY SET CLOSED 1S 04 OPEN SUPERLOD MODE” specaL una zaTON | y-Seactbures “aed en ONCE ONLY (ALL OTHER POLES MUST BE CLOSED) + THS SWTCH SETTAG § USED TO NTALZED NVRAM CONF GLRATON SPACE THS ENABLES THE MOOULE TO RECOVER FROM SOME ERROR MODES. = ON-LINE CONF GURATION = OPEN — N1BT NVRAM CHECK — OPEN = NABT EPROM = OPEN NORMALLY = RESERVED SET ~ COMPACT NVRAM FREE SPACE = OPEN CLOSED = NTAL Ze NVRAM = OPEN = CLOSED = PRIMARY MFC OPEN — SECONDARY MFC 1 & 4 OPEN = SUPERLOOP MODE 1 & 3 OPEN — PLANTLOOP MODE * ) OVOunuNn f Sw ‘Swe if2[sf47s[el7felt[2]3[4 [sels tfolxt Tt ol Tofolxfoto REFER TO PROOUCT NSTRUCTION E83 90E=13 FOR FURTHER NFORMATION ON MUFCOS FEFER To PRODUCT NSTRICTION FOR FUTHER RFORMATION ON MMMFCOS @® 90 (Blalill wee reno oyun oo (RITCY CAD FLE— 76027339 _\\\_. Seka coke = 8/A00542 REMOTE NPUT/OUTPUT MODULE SWITCH SETT NGS S s (O000000 FEN NR O01 2 suvguogo) ss (O00 ooG000) u NOTES. 1 SWITCH SET OPEN = LOGC 1 2 S1 HAS 2 FUNCTONS DEPENDING ON WHCH MODE THE NROOI S OPERATING N N REMOTE MODE S!_SELECTS NODE ADDRESS (8=(SB) N LOCAL MODE Si SELECTS SLAVE ADDRESS $1 = 3 TO 8 SELECTS ADDRESS (8=LSB) St - 7 TO 2 NOT USED 3. S2 SELECTS OPERATION MODES $2 = = D AGNOSTIC MODE = NORMAL RUN, S2 2 OPEN = REMOTE MODE (REMOTE MASTER PROCESSOR) = LOCAL MODE (REMOTE SLAVE PROCESSOR) $2. 3 OPEN - NHBT CHECKSUM ROUT NE = PERFORM CHECKSUM ROUTNE $2 - 4708 = MODULE BUS ADDRESS = D SABLE MODULE BUS = D SABLE MODULE BUS TO 11111 = ENABLE MODULE BUS (D AGNOSTIC MODE ONLY) SEE SHEET 42 FOR FURTHER DETALS. tel@ ) 8/A00542 NETWORK 90/NF 90 AL7602738 SHT 41 — GAD FILES Jeoz73e1 \\\ . S\N eck < 1 2 AL7602730 SHT 40 = CAD PLE 76027340 \\\ » Se \n setts = eo(ttamnay 2° EBB Bg CFER q° NDS 02 MDS 02 NOTES SWITCH SET OPEN = LOGC 1 SWI SELECTS SLAVE /GROUP ADDRESS FoR LumiOi/01A sun — 1 7B 4 = GRoue A appREss (4n/sB} Swi— 5 TO 8 = GROUP @ ADDRESS (8-LS8) FOR LMMU2/MFC/MEP SWI 1 AND 2 MUST BE CLOSED ‘SWI — 3 TO B SELECT SLAVE ADCRESS (8=LS8) Jl TO u16 SELECTS PONT VOLTAGE. 1-2 - 120VAC 2-3 = 125V0E 3-4 = 24v0C JI7 TO J32 SELECTS PONT RESPONSE TME 1-2 — 2.3.5 02 SLOW 3 4 - DC FAST 0S 02 MUST 4AVE P.GGY BACK BOARD NSTALLED (KT # 258355) WHEN WORKING WITH AN NLMMO1 OR NLMMO1A REFER TO PRODUCT INSTRUCTION £83-913-20 FOR FURTHER NFORMATION oN NOSIG2 REFER “0 PRODUCT NSTRUCTON E96-307 FOR FUTHER NFORMATON ON MUSuZ NETWORK 90/NF 90 8/A00542 REMOTE NPUT/OUTPUT MODULE SWITCH SETTNGS (con't) 4 S3 AND S4 SELECTS MODE AND CABLE TYPE | N REMOTE MODE 3S 3 i2[3]41sfe] 718 Peeeeere x[xbxfyfifofoyo ofojofofofofoto N LOCAL MODE 33 S. T213]/415 6) 718 T[2[3]4 15161715 xixPxtyfori tr Thapar WHERE X = SWICH MAY BE OPEN OR CLOS_D Y = OPEN = FBER OPTIC CABLES APE USED. CLOSED = ELECTR CAL CABLES ARE USED Si TJ2]sy4{s]ey 778] 11213 0 0 S5 SARIS GE CIRIESE SEE PRODUCT INSTRUCTION £93-908-18 FOR FURTHER INFORMATION ®@® network 20/xF 90 [Bla ey 87a00542 |AL760273C SHT 42 et Bae OEe SoA NV, Solacebe nt }OP_NTERFA AVE M SWTSH SET NGS NETWORK INTERFACE SLAVE MODULE SWITCH S' TINGS ———— cH. fears | coms ome coos 14 14 NUSO1 oo. oom | | \ nh 01 12345678 12345878 12345678 12345878 OONDG00) (ODDHH000} (ONdHno0o [onDoO 200) EN SA OPEN SW3 OPEN SW? OREN SA NOTES. + SWITCH SET OPEN = LOGC 1 2. SWI SELECTS NODE ADDRESS 1 THROUGH 250 (8=LSB) 3 SW2 SELECTS RNG ADDRESS 1 THROUGH 250 (8=LSB) 4 SWS SELECTS OPERATON MODES ‘SW3-1 OPEN = BRDGE MODE CLOSED = PCU/CU/NU/C/T MOLE SW3-2 OPEN PERFORM ROM CHECKSUM CLOSED = NHIBIT ROM CHECKSUM SW3-3 OPEN = TEST MODE, NO TMEOUT FOR FANDSHAKE FA LURE CLOSED = NORMAL OPERATING MODE SW3 4 OPEN — BUSY NAK Au LOOP WESSAGES CLOSED — NORMAL OPERATING MODE SW3-5 OPEN = WLL TOGGLE ON/OFF GROUP A LEDS F LOOP 11S DLE OR SHORTED OUT WLL TOGGLE ON/OFF GROUP B LEDS F LOOF 2 S$ DLE OR SHORTED OUT F BOTH LOOPS ARE GOOD, NORMAL LED DSPLAY AS DEF NED 8Y SW4 CLOSED = LED DISPLAY AS DEF NED BY Sw4 SW3 6 OPEN = ENABLE XM TTER “ERROR TYPE” CHECK CLOSED = DSABLE XMTTER "ERROR TYPE” CHECK SWS 7/8 CLOSED/CLOSED = 10 MHZ LOOP (SU?ER LOOP/NF_NET) CLOSED/OPEN = 2 MHZ LOOP (SUPER LOOP/NF NET) OPEN/CLOSED = NOT USED ol OPEN/OPEN = S00KHZ LOOP (PLANT LOOP) @@3 SEE SHEET 44 FOR FURTHER DETALS Ss NETWORK 90/NF 90 8/M |AL760273F SHT._43 : CAD FILE— 76027343 QQ\qur yon’ LOOP INTERFACE SLAVE MODULE SWTCH SETTNGS con't 5. SW4 POLES 1 TO 3 SELECTS THE NLSO1/NN SOI EXPANDER BUS AODRESS (3=LS8) ‘SW4 POLES 4 TO 8 SELECT EVENT/ERROR COUNTERS ADDRESS (8-LSB) 6 JI TO J6 SELECTS BAUD RATE (MUST MATCH SW3 POLES 7/8) ALL SX JUMPERS MUST BE SET TO SAME POSTON *=2 = 500Knz (PLANT LOOP) 2-3 = 2MHz (SUPER LOOP/ NF ~NET) 3-4 0 MHz (SUPER LOOP /INFI-NET) 7. SWI,SW2 & SW3 MUST BE SET DENTICALLY ON REDUNDANT NLISO!S/INN SOt'S (670-N90-2842) aye ET BLA] 2] 313475] 36. ws etal FOR FURTHER INFORMATION ON NLISO! SEE PRODUCT INSTRUCTION £93-908-7 FOR FURTHER INFORMATION ON INNISO' SEE PRODUCT INSTRUCTION E96—80t NETWORK 80/INF_ 90 AL76027F SHT. 44 : CAD FILES 76027344 _\\\. Se\n cde 87000542 1 |AL760273G SHT. 45, [CAD FLE~ 76027345 + Se\nceky SUPER LOOP BUS MODULE SWITCH SETTNG 12345678 om (ONCOOOND 7 OPEN 12545878 swe 111000000 a. OPEN NOTES SWITCH SET OPEN = LOGC 1 2 SW3-1 OPEN = MFC MODE, ALWAYS SET TO 1 SW3—2 OPEN = HARDWARE D AGNOSTC MODE ENABLED CLOSED = HARDWARE D AGNOSTC MODE 0 SABLED SW-3 TO 7 NOT USED SW3—8 OPEN = MODULE US ADDRESS 1 CLOSED — MODULE BUS ADDRESS 0 3. SW4 SELECTS OPERATON MODES (MUST BE SET DENTICALLY ON REDUNDANT NSBMO1 S_.670-N90—2842) SW4—1 OPEN ~ NHET ROM CHECKSUM CLUSED = PERFORM ROM CHECKSUM SW4-2 OPEN — FAL OVER TO REDUNDANT SBM ON POWER SYSTEM STATUS FALURE (670 NF 90-2871) CLOSED = DSABLE FAL OVER TO REDUNDANT SBM ON POWER SYSTEM STATUS FAILURE (670 NF 90 2871) SW4-3 GPE ~ REDUNDANCY SELECTED (BOTH MODULES MUST BE SET ) GLOSED = NO REDUNDANCY SW4—4 OPEN = SUPER LOOP DIAGNOSTCS ENABLED CLOSED = SJPER LOOP D AGNOST CS 0 SABLED SW4~5/8 (EXCEPTION REPORT POLL RATES) ‘OPEN/OPEN = 8 POLLS/SECOND (FAST) CLOSED /CLOSED = 1 POLL/SECOND (SLOW) CLOSED /OPEN = 2 POLLS/SECOND (SLOW) OPEN/CLOSED = 4 POLLS/SECOND (STANDARD) SW4-7 OPEN = TEST MODE ENABLED CLOSED = TEST MODE DSABLED SW4-8 NOT USED (NOTE, MUST BE SET DENTICALLY ON REDUNDANT SEM S ‘SEE EN 670-NSO-2842) Se FOR NSSMOT SEE PRODUCT NSTRUCTION 8: @ 1e 908-7 NETWORK 90/NF 90 8/A00542 PI P_ ST TCH TT NGS | NF--=NET TO COMPUTER NTERFACE SWITCH SETTINGS TO MEMORY CARD P4 NCTO1 NSSWO! TO MEMORY CARD PS Pu CARO PS PA yasase7e 12345678 12548 (goaocood quuoa0d (goon NOTES. 1, SWITCH SET OPEN = LOGC 1 2 SWITCH U72 SELECTS OPERATNG OPT ONS: U72-1 OPEN “= NHIBT ROM CHECKSUM SLOSED — PERFORM ROM CHECKSUM U72-2/3 = PORT 0 & 1 DATA CHARACTERISTICS ~ CLOSED /CLOSED BTS, 1 STOP BT, NO PARITY CLO: PEN 1g] S108 BT EVEN Patty 2 IN 8 BTS, 1 OPEN/CLOSEL BTS, 1 STOP BT. ODD PARITY OPEN/OPEN = 8 BITS, 2 STOP BITS ‘NO PAR TY U72-4 OPEN = PORT 1 OPTON = MCS/OS OR TERMNAL (UTL TY) CLOSED = PORT 1 OPTION = EWS(COMPUTER) | U72-8 OPEN = MODEM, PASSWORD, PROTECT ON ON = MODEM PASSWORD PROTECTION OFF 72-6 GEN = PORT ADDRESENG HOSE GN CLOSED = PORT ADDRESSNG MODE OFF U72-7 OPEN = CHECKSUNMNG ON = CHECKSUMM NG OFF 72-8 GEEN = SECONDARY S2M/OT CLOSED = PRIMARY SSM/{CT 8 8 Br oP. SEE SHEET 47 FCR MORE DETAILS 1® 1 NETWORK SO/NFI 90 8/A00542 }AL7602730 SHT. 46 \ ~ [ea PER 76027346 Wada eke POLES 1 TO 4 POLES 5 70 6 — BAUD RATES 0 1 2 3 U75=1 OPEN, CLOSED U75~2 OPEN U75-3 OPEN CLOSED, OPEN/< ‘SUPER LOOP STORAGE MODULE SW TCH S= 3 SWTCH U73 SELECTS TRANSM SSION RATES FOR TWO RS232 PORTS TERMNAL PORT (1—LSB) FRNTER PORT (5—LSB) 150 B= 18K 12 - 48K 300 9 = 2K 13 73k 600 10-24 14 = 98K 12K 115 36K 18 = 18 2k 4 U7S SELECTS ADDRESS AND TEST MODE TEST MODE ENABLE (1 S/NIS HANDSHAKE TMEOUTS GNORED) NORMAL OPERATNG MODE LS/NIS_D AGNOST.CS ENABLED CLOSED — NORMAL OPERATNG MODE. DAGNOST CS ENABLED CLOSED ~ NORMAL OPERATING MODE u75~4/5 CLOSED/CLOSED = SSM/C™ ADDRESS 0 EN = SSM/ICT ‘ADDRESS 1 (SsE0 = SM /CT ADDRESS 2 OPEN/OPEN = SSM/ICT ADDRESS 3 7 ws Us if2]3]4 [5 7e[7 6a [2 [3] 4Ts]e]7 8) 1213145 ooo} |AL7602750 SHT. 47. [CAD FILE— 76027347 REFER TO PRODUCT INSTRUCTION £93-908-7 FOR FURTHER NFORMATION ON NSSMOI REFER TO PRODUCT NSTRUCTION E96~601 FOR FURTHER INFORMATION ON NCTOI NETWORK S0/INF 90 TNG' 1 }AL760273C SHT. 48 = \\ Wy CAD FILE 76027348 » Ste RAI IMMUN CAT ON MODU \W TCH TTNGS NF =NET TO TERMINAL TRANSFER MODULE SWTCH SETTINGS s TO MEMORY CARD P4 NITTOI NSCMO1 TO MEMORY CARD PS PU CARD PS Pe sasase7s — rz3ase7a 12588 00000000 (goonan00 00000} c NOTES: SWITCH SET OPEN = LOGC 1 2 SWITCH U72 SELECTS OPERATNG OPT ONS. U72-1 OPEN = INHB~ ROM CHECKSUM CLOSED = PERFORM ROM CHECKSUM U72-2 FUTURE U72-3/4 CLOSED/CLOSED = NO PARTY - PORT 0 CLOSED/OPEN = ODD PARTY PORT 0 OPEN/CLOSED = EVEN PARTY ~ PORT 0 OPEN/OPEN = NO PARTY — PORT 0 U72-5 OPEN =" 2 STOP BTS — PORT O CLOSED = 1 STOP BT — PORT O U72-6 OPEN = DATA LENGTH 8 BTS — PORTO LOSED = DATA LENGTH 7 BTS — PORT 0 u72-7 OPEN = INITALIZE NODULE CLOSED = NORMAL OPERATNG MODE u72-8 = NOT USED 3. SWITCH U73 SELECTS TRANSMSSION RATES FOR TWO RS232 PORTS. POLES 1 10 4 = TERMINAL PORT (1=58) POLES 5 TO B = PRINTER PORT (5=LSB) BAUD RATES. O = 50 4=150 8 =18K 12 = 48K 1= 75 5 = 300 = 2K 13 - 72k 2= 110, 6 = 800 24K 14 = 36K 321345 7 = 12K 36k 15 = 192k SEE SUEET 49 FOR SURTHER DETALS NETWORK 90/INF 90 @|® © §7a00542 an r 4 U75 SELECTS PORT 1 OPTIONS. U75 1 OPEN ~ PORT 7 OTE SELECT CLOSED PORT 1 OCE SELECT U75-2/3 CLOSED/CLOSED = NO PARTY PORT 1 G.OSED/OFEN ODD PAR’ PORT + OPEN/CLOSED EVEN PARTY, PORT 1 OPEN/OPEN ~ NO PARTY — PORT 1 U75 4 OPEN = 2 STOP BIS PORT 1 CLOSED = } STOP BT - PORT 1 75-5 OPEN” DATA LENGTH @ BTS - PORT 1 CLOSED = DATA LENGTH 7 BTS PORT 1 U72 U7 Uys REFER TO PRODUCT NSTRUCTION £93-S05 11 FOR FURTHER NFORMATION ON NSCMOt REFER TO PRODUCT NSTRUCTION FOR FUTHER NFORMATION ON NTTOI : . NETWORK 90/INFI 90 |AL760273D SHT. 49 GAD pe~ 7e0s7549 NN? Scnech in x SER AL COMMUN CATON MODULE SWITCH SETT NGS con ¢ N. MMAND_ CONTR: R_SW TCH TTN cscol 12345678 xU40_ ss _. (guga0ong — 12345678 s2|00000000) xU47 oR NOTES. 1 SWITCH SET OPEN = LOGIC 1 2, S14 TO & SELECTS ADDRESS (8=LSB) 1-2/3 SELECTS BAUD RATE FOR RS232 PORT CLOSED/CLOSED = 300 CLOSED/OPEN = 12K OPEN/CLOSED = 2.4K OPEN/OPEN = 9 6K S11 UNUSED 3 S2 SELECTS D AGNOSTIC TESTS OR FACEPLATE OPTIONS AND STATON ADDRESS $2-1 TO 3 SELECTS STATION ADDRESS (1=LS8) S2=4 UNUSED . S2-5 OPEN = FACEPLATE LED'S ARE GREEN FOR 'OFF” COND TION OF /0 CLOSED = FACEPLATE LEO'S ARE RED FOR “OFE"GONDTION OF /S 82-8 OPEN = FACEPLATE LED'S ARE E.COLOR FOR /O STATUS CLOSED = FACEPLATE LED'S ARE MONOCOLOR FOR /O STATUS S2-7 OPEN = SELECTS FACEPLATE OPTONS (NORMAL MODE) CLOSED = SELECTS DIAGNOSTIC MODE, REMANNG POLE SELECTS VARIOUS TESTS S2-8 OPEN = ENABLE AUD BLE ANNUNC ATOR WHEN ALARM CONDITION EXISTS CLOSED = DISABLE AUD BLE ANNUNCIATOR 4. $3 SELECTS OPERATION MODE $3-1 NOT USED S3-2 NOT USED $3-3 OPEN = NHBT NVRAM CHECKSUM CLOSED = PERFORM NVRAM CHECKSUM SEE SHEET 51 FOR FURTHER DETALS NETWORK 90/NF 90 AL760273C SHT. tr \ Cad PLE~ 76639350 Wy be 7 8/A00542 fae SEQUENCE COMMAND CONTROLLER MODULE WW TCH TTN n” 2 N3a0. ze nn | OPTONAL MANUAL CONTROL BOARD aa aS SEE SHEET 53 FOR FURTHER DETALS NETWORK 90/NF $0 |AL760273D SHT.52 \ CAD FLE- 76027352 _(\\ Sola eee” SEQUENCE COMMAND CONTROLLER MODULE SWITCH SETTNGS con’t L Tas aca cas > (i000 nes 7 oom tt AUT BOARD OUTPUT BOARD NOTE: 1. SWITCH SET OPEN ~= LOGIC t 2 JUMPERS J1 TO JS DETERMINE NPUT VOLTAGE LEVELS NPUT BOARD JUMPER | POSITION |DESCR PTON a 1=2 [CONF GURES Di-012 FOR AC OPERATION 2-3 |CONF GURES NON— SO_ATED OGTAL_NFUTS 1 THROUGH 12(0 1-0 12) FOR OC OPERAT ON. v2 1=2 [CONFIGURES D13 FOR AC OPERATON 2-3 |CONFIGURES SOLATED DG TAL NPUT 13 (0113) FOR DC _OPERAT ON 7-2 [CONF GURES DIi4 FOR AC OPERATON 2-3 |CONFIGURES ISOLATED DG TAL NPUT 14 (N14) FOR DC OPERAT ON 4 7=2 [CONF GURES D15 FOR AC _OPERATON 2-3 |CONF GURES ISOLATED DGTAL NPUT 15 (OS) FOR OC OPERAT ON 3 1=2 [CONFIGURES 016 FOR AC OPERATON 2-3 |ROUNOURES, SCLATED,O.GITAL NPUT 16 (06) FOR OG OPERAT ON 3 3. S1 DETERMINES /O ADDRESS THE LEAST SGNFCANT BIT S FABR CATED ON BOARD SO THAT THE NPUT CARD HAS AN EVEN ADDRESS AND THE OUTPUT CARD HAS AN ODD ADDRESS (ADDRESSES 0 OR 1 ARE NVALD) THE NEXT LEAST SGNF CANT BIT IS POLE 1. REGRIG.GROOUST NSTRUCTION €92-500—4 FOR FURTHER MATION: B ener airs. = Network 90/n so [B/A CAD FILE "76027353 \\\. 8/0005420® i U72-8 OPEN = REDUNDANCY REQURED RDGE COMMUN CATON MODULE SWTCH SETTNGS NF-NET TO_NF-NET TRANSFER MODULE SWITCH SETTNGS - TO MEMORY CARD Ps N Tot Nacwor TO MEMORY CARD PS cru CARD PSP sasasere 123458 1334s Qncoo0o0} © (O0e00000) [oneng NOTES: 1 SWTCH SET OPEN = LOGC 1 2 SWTCH U72 SELECTS OPERATNG OPT ONS: v72—* OPEN = NHB T ROM CHECKS. CLOSED = PERFORM ROM CHECKSUM U72-2/3 PORT 0 & 1 DATA CHARACTER STICS, CLOSED/CLOSED = 8 DATA BTS 1 STOP BT, NO PARTY SLOSER/OREN = 8 DATA TS, | STOP BT, EVEN PAR Ty SSEN/CLOSED = 8 DATA BITS, * S10 BT. OOD Pak Ty QPEN/OPEN = 8 DATA BTS, 2 STOP BTS, NO PAR TY U72-4/5 EXCEPT ON REPORTNG RATES (TME BETWEEN SCANS) CL OSED/CLOSED = 2.0 SECONDS * CLOSED/OPEN” = 1.6 SECONDS OPEN/CLOSED — 0.5 SECONDS QPEN/OREN = 025 SECONDS U72-6/7 UNUSED. SELIHE SAME ON REDUNDANT MODULES) LOSED = REDUNDANCY NOT REQU RED” 3. U73 SELECTS TRANSMISSION RATES FOR TWO RS232 PORTS ES 1 TO 4 = TERMINAL PORT (1-156) POLES 5 18 & = PRINTER PORT (SuLSBH BAUD RATES. O= 50 4= 150 8 = 18K 12 - 48K 1275 5= 300 9520 13-72 2-10, 6= 800 10=34 12 5 96K Sa 1S 7a TK Me 3K B= I82k | SEE SH 59 FOR FURTHER DETALS ® |AL760273¢ SHT._ 54 ‘ Pe eee oe CAD FILE= 76027354 \N\ . Sncetds 13700542 4 u75-1 u7s-2 U75-3 u75~4 u75-5 SEE SEE jal 7602750 SUT. 5S AD F LES, COMMUN CATON M SWITCH SETTNGS (CON’ OPEN = TEST MODE ENABLED (L.S/NS HANOSHAKE TIMEOUTS GNORED) CLOSED = NORMAL OPERATING MODE UNUSED OPEN — DAGNOSTC PORT ENABLED CLOSE = NORMAL OPERATNG MODE CONTROLS TME-SYNC SOLATION BETWEEN THE CENTRAL AND SATELL TE RNGS (EN—670-NSO~2725A) CLOSED ~ CENTRAL AND SATELL TE RNGS ARE SYNCHRON ZED TC A COMMON TME BASE OPEN — CENTRAL SATELLTE RNGS WLL HAVE. NDEPENDENT TME BASES AND MASTER NODES SELECTS MODULE BUS ADDRESS (EACH MODULE OF A REDUNDANT SET MUST HAVE A UN QUE ADDRESS EN 870 NF 90-3014) CLOSED ~ MODULE ADDRESS 0 OPEN = MODULE ADDRESS 7 u72 U7 UTS *[2[3]4]s]6]7 [8] [21314 [s]6] 78 [213] 4/5 ‘010 of [ole PRODUCT INSTRUCT ON E93-908-7 FOR FURTHER NFORMATON ON NBCMOt PRODUCT NSTRUCT ON E96-601 FOR FURTHER NFORMATION ON N TOI i ? NETWORK 90/NF 90 76027385 > 4 r ANALOG NPUT TERMNATON MODULE TERM NAL 32 PI CONNECTOR} EPEC NOTES: NAOT 1 THE D PSWICH NUMBER CORRESPONDS NUMER CALLY TO THE ANALOG NPUT NUMBER 2SWITCH SET OPEN = 0 j¢- TERMINAL 1 ‘APPL CAT ON/SGNAL TYPE ANALOG NPUT VAR ATIONS . 1 SYSTEM POWERED 4—20mA 1 EXTERNALLY POWERED 4—20mA ° DFFERENT AL VOLTAGE, ° SNGLE_ENDED VOLTAGE ° @®® REFER TO PRODUCT NSTRUCTON £93-911 FOR FURTHER NFORMATON| AL760273C | SHT 56. NETWORK 90/NF 90 CAD FILES _ 76027356 : 1B/A00542 ANALOG INPUT TERMINATION MODULE TERMINAL 32 CONNECTOR] NOTE, we He TERMNAL 1 1 SWITCH SET OPEN - 0 2$1 TO S15 SELECT ANALOG NPUT OPTIONS. (OFS WITCH NUMBER CORRESPCNDS “uMER'CALY TO THE ANALOG INPLT NUMBER) POLE: 12345678 SYSTEM POWERED 4—20mA 12111100 EXTERNAL.Y POWERED 4—20mA ooooriit BEreRINT AL VOLTAGE $080 bbT SNGLE ENDED VOLTAGE oeotornt ‘3S16 SELECTS WHICH MODULE/SLAVE THE NAO4 IS NTERFACED WTH roe 1s S458 ‘AMMO1 /ASMO1 100110 ASOT /AS 02 011001 REFER TO PRODUCT NSTRUCTION £96463 FOR FURTHER NForwaTon ©@® ALT60273€ SHT 57 < network 90/Fi 90 (BIA! CAD FILE 76027357 _\\\- ho cz 18/A00542 ao ofa ofa 8 c >| s}ofor] fests} — jojojofololelo|=|= ofolololoto Slolofolo}-lolola| ololofolol-lolol~ ajolo|—lole fololo}=lolo} 3]--[ofololololols} PHflefeleelel= ° 3 SW TCH, S2, $3 & S4 ENABLES PROPER COMMUN CATION BETWEEN REDUNDANT AMM! PRIMARY NIAMO2 "SECONDARY N AMO2] 0] 1 fol allele = Tole ha fol-fal“ ia = ola] | fol=|~ =o} © ® 18/A00542 REFER TO PRODUCT INSTRUCT ON €93-911 FOR FURTHER NFORMAT ON; |AL.7602730 _SHT 58. NETWORK 90/INFi SO GAD FIE= 76027358 Wx: Sc\wochoe — f ~ ANALOG MASTER TERM NATON MOCULE | i a CONNECTOR} (eeseese] TERM NAL 6 NOTE: A ogres er eee TERMNAL 1 3 SWITCH ST WANBULATES R10’S FOR THE ANMO2/ANMO3 WHEN ASMO2'S ARE USED NOWBER OF si RTD ASMO2'S PAR A ANALOG OUTPUT TERM NAT ON MODULE TERMNAL 25, NOTES puis se Fl€- TERM NAL 1 1 SWITCH SET OPEN = 0 2 SWITCH St TO SB SELECTS OUTPUT OPTIONS pout numeer [1 ]2]3[a 41=5 voc ofetiys 4-20mA sfofofo| SFUSES Fl & F2 = 3 AMPS network 20/nA1 30 [BI }AL7602730_ SHT 59 CAD FILE 76027359 \\\ faa PL CONNECTOR Ncso1 NOTE. 1. THE ANALOG NPUT OD PSWITCH NUMBER CORRESPONDS TO THE ANALOG INPUT NUMBER: 2SWTCH OPEN = 0 CONTROL _NTERFACE SLAVE/CONTROLLER/STATON TERN NATON MODULE) NUMERICALLY 3 5 ANALOG NPUT VARIATIONS ‘SYSTEM POWERED 4—20mA EXTERNALLY POWERED 4-20mA SINGLE ENDED VOLTAGE (1~SVDC) DFFERRNTIAL VOLTAGE (1-SVDC) Soo 4/25] Flo 0 = =u in| a on 1 ES + ofc | gjoco=ls a] g ANALOG OUTOUT VARIAT ONS ul= = olN a BOTH OUTPUTS ARE 1=5 V DC OUTPUT 1 S 1-SVDC, OUTPUT 2 IS 4-20mA 0¢| OUTPUT 1S 4—20mA DC, OUTPUT § 1-5¥DC BOTH OUTPUTS ARE 4-20mA OC loo al Bloo0 alu loo = =| Zio + 0 =} 9 lo so -lu a lo +0 aa Flo + + ao NETWORK 90/NF 90 AL7602730 _SHT 60 \ oS \ CAD FILE 76027360 Sow eker REFER TO PRODUCT NSTRUCTION £93-911 FOR FURTHER NFORMATION §/n00542 O@ MULT —FUNCT ON CONTROLLER TERM NAT ON MODULE. Pt CONNECTOR ES} NOTE: 1 1-10 REPRESENT STRAP NUMBERS ON DIPSHUNTS XU1 THRCUGH xXU4 WHERE O REPRESENTS A CUT STRAP AND 1 REPRESENTS A STRAP LEFT NTACT TPEUNT CONF CURATION APPLCATON SGNAL TYPE | DIPSHUNTS 12345678910 COMPUTERS — Te BC™ AND COMPATIBLE, CoMPAQ® | xut/xU3 } 1110011010 TERM NALS—VT1. ADM3 XU2/XU4 oo010100000 VISUAL 50, WYS= (WY50) TELEV DEO SEQUENT AL EVENTS XU1/XU2, NOT USED RECORDER xU3 1110000010 wos [0000111000 REFER TO PRODUCT NSTRUCTION 93-911 FOR FURTHER NFORMAT ON. |AL760273 C_ SHT 61 [CAD FLE— 76027361 __ NETWORK $0/INFI 80 PLANT LOOP/SUPER LOOP TERM NATON MODU J#- TERMNAL 32 ¢ TERMNAL 25 J-TERMNAL 11 I-TERMNAL 1 NOTE THERE ARE TWO VERS ONS OF NCLO1's THE BOARD MUST BE VSUALLY NSPECTEO TO DETERMNE VERS ON SEE SHEET 92 FOR NFORMATON ON THE OTHER VERS ON (APPROX MATE DATE OF BOARD CHANGE S MAR 1980) 2 J3 TO J7 AND JiO TO JIB SELECTS CABLE TYPE USED FOR PLANT LOOP OR SUPER LOOP 3 JT, u2, vB, AND v9 ARE BNC CONNECTORS FOR COAX CABLES PLANT LOOP: SUPER LOOP i TWINAX COAK TWNAX | COAX JUMPER No (i= 2)0R(2=3)] (I= 2)OR(2—3) = 2)OR(2_ 3) 2)OR(2=F 3,10. G=2) = G=2)_ | (2-3) Te Jt = Fal O=3) (2=3) 3) (23) NS = 18 (23) Q=3) 1-2) (23) REFER TO PRODUCT NSTRUCTION £93—911 FOR FURTHER NFORMATION @@¢ 8 BalilleYz }AL7602738 SHT 62. on 7 NETWORK $0/NF 30 <= CAD FLES 76027362 \\\ SS ca) B PI P / NF =NET TERM NATON UN T td BREE BEE thes vTcLot (663699741) BR ORE a] | i e NOTES. 1 THERE ARE TWO VERSIONS OF NTCLOIs PLEASE NOTE ASSEMBLY NUMBER FOR VERS ON SEE SHEET 14 FOR INFORMATON ON 663699701 (APPROX MATE DATE OF BCARD CHANGE S NOV '990 2 J3 TO J7 AND JIO TO Ji8 SELECTS CABLE TYPE USED FOR PLANT LOOP OR SUPER LOOP/NF NET 3 Jt, 42 JB, AND J9 ARE BNC CONNECTORS FOR COAX CABLES v= LOOP 1 2 = Loop 1 our J&8 = LOOP 2 N JQ = LOOP 2 OUT PLANT LOOP SUPER LOOP TWINAX COAX TWNAX COAX JUMPER No__[CT=2)OR(2=3)ICI=2IOR—S)| (I= 2)OR(Z_3)|CT_2OR@=S)| B,J 7=2) (2=3) G@=3) ea 7s = wa] (= 2) G=3) (Q=3) wis — 8 (2=3) (Q=3) G=3) REFER TO PROOUCT NSTRUCTION £93-911 FOR FURTHER NFORMAT ON @@¢ a AL760273E _ SHT 63 nerworx 90/ne 20 Blalillleyls Deo reSarSes WK. Shetty >] ATEWAY CONTR RM W TCH TTN ax JN ———* TO MEMORY CARD P4 ecmor TO MEMORY CARD PS cpu CARD | FS PA sa345678 2345578 1350s (gtooo000 (onuoooag ores: 1 SWITCH SET“OPEN’= LOGC 1 2u1 - 2 ~ 3 SELECTS EPROM TYPE INSTALLED JI - J2 = 27256 J2 - J3 = 27128 3.U72 SELECTS OPERA™NG OP™ ONS: U72-1 OPEN = NHIBT ROM CHECKSUM CLOSED = PERFORM ROM CHECKSUM U72~1 OPEN = DTE MODE SELECTED CLOSED — OCE MODE SELECTED 72~3 OPEN = EQUIPMENT SELECT OUTPUT ENERGIZED CLOSED = EQUPMENT SELECT OUTPUT DE-ENERG ZED U72-4 OPEN = UTLTY 72-5 SERREO Ree” \Y COMMUN CATION: u72~ = 7 CLOSED = Local 7 GATEWAY D U72~6 OPEN = ONE WAY CONTROL CLOSED = TWO WAY CONTROL U72~7 OPEN = IN TIALIZE MODULE. CLOSED = NORMAL OPERA™NG MODE U72-8 OPEN = SECONDARY GCM CLOSED = PRMARY GCM SEE SHEET 65 FOR MORE DETALS . NETWORK 90/NF 90 AL7602738 SHT 64 . CAD FILE~ 76027364 NN Sk ake §7A00542 GATEWAY CONTROLLER MODULE SWITCH SETTNGS con't | | 4 SWITCH U73 SELECTS TRANSM SSON RATES FOR TWO RS252 PORTS POLES 1 TO 4 — TERMNAL PORT (1~LSB) u POLES 5 70 8 ~ PRNTER PORT (5~LSB) BAUD RATES. O= 50 4= 150 8=18kK 12 - 48K 1-78 55300 92 20K 13 = 73K 2= 110, 6 = 600 10-24 14 - 96K 321345 7-12 11> 38K 15 ~ 196k 5 SWITCH U75 SELECTS NODE ADDRESS 0 THROUGH 31 (5-LSB) U7z U73 U5, siefie wa eee REFER TO PRODUCT NSTRUCTION E93-908-14 FOR FURTHER NFORMATION aazeoazse sures ee ee ee GAD FILE 76027365 : [es REMOTE NPUT/OUTPUT MODULE SWITCH SETTNGS . | MR 002 are NR O02 | 12245678 12345678 12345678 s= (QU¢UO00o) = (ONOGO00} + [DooggOUD] NOTES, 1 SWITCH SET OPEN = LOGC 1 2 Si HAS 2 FUNCTONS DEPENDING ON WHCH MODE THE NROO2 S OPERATNG N REMOTE MODE_Si_SELECTS NODE ADDRESS (8=LS8) N LOCAL MODE ST SELECTS SLAVE ADDRESS 51 — 3 TO 8 SELECTS ADDRESS (8=LSB) $1 = 1 “0 2 NO™ used 3 SZ PROVIDES NO USER OPTIONS AND MUST BE SET AS SHOWN MODE $2 T2qsl4{slel7 8 Revore |Olofojofofo|o o tocat “Tol ifofofofoloto 4 $3 AND S4 SELECTS MODE AND CABLE TYPE N REMOTE MODE $3 4 IARCIEGEE! IEAEIIEI EAC xix[xTyTifototo. ojofoyoforo N LOCAL MODE 3 | a T2]3] 41S [6] 718 T2Ts]4 [516] 718. xbxtxtyfots ts mehr ahhs WHERE X = SWITCH MAY BE OPEN OR CLOSED Y = OPEN = FBER OPTIC CABLES ARE USED CLOSED = ELECTR CAL CABLES ARE USED SEE PRODUCT NSTRUCTON £93-308-21 FOR FUTHER NFORMATION ON NR1002 SEE PRODUC” NS"RUC™ ON E96-317 FOR FUTHER NFORMA™ON ON MROO2 @@ 87A00542 ‘ network 90/nF 90 (BIal ey, |AL760273C SHT.66 \ CAD FILE 76027366 NG Srvetcc NETWORK PROCESSOR MODULE SWITCH SEITNGS i> (fittii~ 5 NNPMO1 | JUMPER POSTS NOTES 1 SWITCH SET ‘OPEN = Locc 1 2 SWITCH SW3 1 CLOSED FOR NORMAL OPERATIONS, OPEN FOR MFP D AGNOSTC MODE ENABLED ‘SW3-2 UNUSED Sw3 3 CLOSED FOR CON"ROL WAY MODE (* Mnz) OPEN FOR MODULE BUS MODE (83.3 kHz) SW3 4 5, 6, 7 UNUSED SW3 8 C.OSED FOR MODULE BUS ADDRESS 0” OPEN FOR MODULE BUS ADDRESS "17 3. SWITCH SWé SELECTS OPERATING OPTIONS SW4-1 CLOSED ~ PERFORMS ROM CHECKSUM (NORMAL OPERATON) OPEN — INHIB TS ROM CHECKSUMM.NG(USED BY DEVELOPMENT PERSONNEL) SEE SHEET 68 FOR MORE DETALS NETWORK 90/NF 90 ABR BEA WA Sperber AL7602730 _SHT 68 CAD FLE— 76027368 _\\\ neh ote a NETWORK PROCESS NG MODULE SWTCH SETTINGS cont swa-2 CLOSED ~ FAL OVER ON POWER SYSTEM STATUS FALURE 0 SABLED OPEN = FAL OVER ON POWER SYSTEM STATUS FALUR ENABLED SW4 3 CLOSED = NO REDUNDANT MODULE EXPECTED OPEN = REDUNDANT MODULE EXPECTED (SET THE SAME ON RECLNOANT MODULES) Sw4 4 CLOSED — SUPER LOOP D AGNOSTICS D SABLED OPEN — SUPER LOOP D AGNOSTICS ENABLED Sw4-5/8 SELECTS EXCEPTON REPORT POLL RATE CLOSED/CLOSED = 1 POLL PER SECOND (SLOW) CLOSED/OPEN — 2 POLLS PER SECOND (SLOW) OPEN/CLOSED = 4 POLLS PER SECOND (STANDARD) OPEN/OPEN = 8 POLLS PER SECOND (FAST) Sw4-7 CLOSED - DSABLED TEST MODE (D SABLES NS HANDSHAKE TMEOUT) OPEN = ENABLES TEST MODE SW4—8 UNUSED (MUST BE CLOSED ON PRMARY/SECONDARY NPM'S) AL OPTION SWITCHS MUST BE SET DENTICALLY ON REDUNDANT NNPMO1 CONF GURATIONS JUMPERS Jt TO J4 ARE FACTORY SET TO 1 AND 2 DO NOT CHANGE Swe 7 Tele [s14 [sles o ‘of fol | of | flo SEE PRODUCT NSTRUCTIONS E96-601 FOR FUTHER INFORMAT ON q =e Ze B/A00D42, NETWORK 90/NF 90 HYDRAUL C SERVO SLAVE SWITCH SI NGS NHSSO1 MHSSO1 NOTES. 1 SWITCH SET OPEN = LOGC 1 2. SWTCH S1 1 MUST BE OPEN S1-2 TO 8 SELECTS EXPANDER BUS ADDRESS © THROUGH 63 (8 = LSB) 3 SWTCH $2 SELECTS THE GAN FOR NTERNAL ERROR AMPLF ER WHCH COMPARES POSITION DEMAND TO FEEDBACK s2| Bere FOR vt 20 50 1825 1505 1310 10 00 § 00 201 41.10 * ALL OTHER POLES ARE OPEN 4. SWITCH S3 SELECTS D THER OSCLLATOR FREQUENCY ool ws Jonfen fs fou fpo | = $3. = FREQUENCY 0 [1 | 300 Hz (HGH) + To [200 nz (cow) @®® SEE SHEET 70 FOR FURTHER NFORMATON 7 NETWORK 90/NF 90 Balijlely |AL7602730 _SHT 69 \ cao Fie 76027369 WA. Sn ekel 87400542 HYDRAUL C SERVO SLAVE SW TCH SETTNGS con't 5, SWTCH S4 SELICTS D THER OSCILLATOR CURRENT AMPL TUDE. = POE =| AMPL TUDE o [0 [D0 NOT USE oO i 24 MA : 0 “2 MA 1 1 THER_D SABLE) 6. SWTCH $5 SELECTS EXCTATON VOLTAGE OF THE LNEAR VAR ABLE DIFFERENT AL TRANSFORMER (LVDT) $5 oes TT] VOLTAGE o [0 o [4 1 oO 1 4 DO NOT USE 7 SWITCH S6 SELECTS DEMODULATER AND FEEDBACK GAIN. se | CLOSE | FOR A POLE «| GAN OF 150) 700 75 49 20 10 499 2.00 * ALL OTHER POLES ARE OPEN ee T i T aa t REFER TO PRODUCT INSTRUCTION EB-913~17 FOR FURTHER INFORMATION ON” NHSSO1 REFER “0 PRODUCT NSTRUCTON E96~3'S FOR FLTHER NFORMATION Oh MHSSOt \ Joo] fonts] a fears] — NETWORK SO/INF 90 }AL7602730 _SHT.70 [aD FILE 76027370 WA. SO woh [ae ANALOG SLAVE QUTPUT MODULE SWITCH SETTNGS sweffft) sw 1 sw i 58 vt swsiii sve ff sw7 NASOOt =" swe (fill swf] swollfd] suis rt ce smafif) swi3 ii sw NOTES: 7 SWI SELECTS EXPANDER BUS ADDRESS 0 THROUGH 63 (8 = LSB ; SWTCH SET OPEN = LOGC 1 ) 2 SW2 THROUSH SWI5 SELECTS OUTPUT MODE OF OUTPUTS 1 THROUGH 14 RESPECTIVELY. sw2- swis | po | move [273 +10 [1 | VOUTAce oli to » OPEN - 0, CLOSED = 1 REFER TO PRODUCT INSTRUCTION £93-912—11 FOR FURTHER NFORMATON ON NASOO1 REFER TO PRODUCT INSTRUCTION £96—303 FOR FURTHER NFORMATON ON MASOO1 @® NETWORK 90/NF 90 AL7602730_SHT.71 5 CAD FLE- 76027371 \- SAarotec 87400542 MULTFUNCTON PROCESSOR MODULE SW TCH SETTNGS. | ini ti- | crs 8 - OD ae JUMPER POSTS NOTES 3 SMTCH SET “OPEN” = Loge 1 2 SMICH SWS -'# TO 8 SELECTS MopULE ADDRESS (S=LSB) SWS = 1 CLOSED FOR NORMAL OPERAT O GEER NVORES DAGNOSTICS USNE SWS SWS ~ 2 RESEVED (MUST BE CLOSED) SWS - 3 CLOSED ~ CONTROLWAY (1 oe), SeEN YOR WE BIS (83 5 KHz) 3. SWICH SW4 SELECTS OPERATION OPTONS AND 0 AGNOSTICS (REFER TO PRODUCT NSTRUCTIONS FOR D AGNOSTIC NFORMATION) SW4 = 1 SPEC AL OPERATION — CLOSED = DISABLED OPEN = ENABLED 'SW4 — 2 ON-LNE CONF GURATION - CLOSED = D SABLED OPEN LED, ‘SW4 — 3 BATRAM CHECKSUM ROUTNE - CLOSED = ENABLED = SPEN = DSABLED (DO NOT DSABLE CHECKSUM ROUTINE N NORMAL OPERATION MODE THS SWITCH S USED BY DEVELOPMENT PERSONNEL Swa-4 RCM CHECKSUM ROUTINE ~ CLOSED = ENABL (00 NOT DSABLE CHECKSUM ROUTINE N NORMAL OPERATION MODE. THS SWITCH 'S USED BY DEVELOPMENT PERSONNEL) | §W4” "5 RESERVED (SET 70 CLOSED) SW4 — 6 NVRAM FREE SPACE - CLOSED = NORMAL = _OPEN = COMPACT (NOTE SWITCH MUST BE CLOSED BEFORE ENTERNG CONF GURATON MODE ) | ‘SW4—7 NTIALZE NVRAM — CLOSE = D SABLE | = OPEN = ENABLE (SMTCH MUST BE CLOSED | BEFORE ENTERING CONF GURATON MODE) SW-8 CLOSED = PRMARY MFP OPEN = SECONDARY MFP SEE SHEET 73 FOR FUTHER DETA_S NETWORK 90/NF 90 | AL7602750 SHT.72_ | CAD FILE "76027372 A) Schw ce ee MULT FUNCT ON PROCESSOR MODULE SWTCH SETTNGS (CON’T) 4 SW4 SPEC AL OPERATION SETTINGS QOH = RESERVED DO NOT USE BIH ~ RESERVED FOR FUTURE OPTONS 82H — NITALZE NVRAM CONF GURATON SPACE 83H — RESERVED DO NOT USE 84H ~ NF—NET PRO-OCUL ENABLED ( HS ALLOWS THE MFP TO TAKE ADVANTAGE OF THE NF —NET/SUPER LOOP CAPABL TES) 85H PERM T SEGMENT MODF CATIONS (ALLOWS CHANGE TO SEGMENT SCHEME CONF GURED WTH FC 82 SPEC 1) 86H — ENABLE TME STAMP NG 5. JUMPERS Jt TO J4 ARE FACTORY SET TO 1 AND 2 DO NOT CHANGE 6 JUMPER POST LOCATED TOWARD FRONT EDGE OF BOARD SHOULD NEVER HAVE A JUMPER ACROSS THE PINS. THESE POST ARE USED BY DEVELOPMENT PERSONNEL ONLY. sw sw sl2|3}e}s}e}7}a}1 2 |3]a|s|6|7 (8 | .rj2[u3}ue ojo} jo} lo Jojo are] 2] Ht REFER TO PRODUCT NSTRUCTION £96 - 201 FOR FURTHER NFORMATON ON MFO REFER TO PRODUCT NSTRUCTION £96-202 FOR FUTHER NFORMATON ON MMFPOI 6/a00542 NETWORK 90/NF 90 AL760273¢ SHT 73 \ CAD FILE 76027373 WK Sc\ eke - BATCH COMMAND CONTROLLER MODULE SW TCH SETTNGS (CEU BOARD) ceco!* QU ™. 7 NOTES 3 SMTCH SET “OPEN = Loge 1 2 Smicn S14 TO a sevecTs anoaess (s = (sa) 2: LPR ae Bes aa eavee Seen eiosen = a8 OPEN/OPEN = 9500 3 SWITCH S2 SELECTS 0 AGNOSTIC TESTS OR FACEPLATE OPTIONS AND STATON ADDRESS 33 = 2 IRR SHEETS SranON anoness (1 = 58) 324 Ao 52 — 3 ReseRven [oe Factory, BTL FUUcTON (wuss BE C.CSED) 6 OBEN = FACEELATE. (a INDICAT Sant EOF NooE OF THE cobe closto = FAGEPATE Uh anit? MB CATING E'S ane Res AUTOMAMC MODE OF S27 OPEN = SELECT FAGERLATE OPTIONS AND STATON ADDRESS wee 4 swton s3 seurclS OeeRanans moot” GSE out wa SonttnSt ew was cater som ERROR THEREFORE NORMALLY NOT USE0}) SFE SHEET 75 FOR FUTHER DETALS NETWORK $0/NF 90 |AL7602738 SHT 74 CAD FLE— 76027374 Saved c BATCH COMMAND CONTROLLER MODULE SWTCH SETTNGS (CONT) (CPU BOARD) 83 3/4 CLOSED/CLOSED = NYRAM AND EPROM CHECKSUM ROUTINE ENABLED oral GoeakTiON) ‘OPEN/OPEN = NVBAMU AND EPROM CvECKSUM ROUTINE DISABLED (USED BY" DEVELOPMENT PERSONNEL) S38 2/8 CLOSED/CLOSED = UNUSED S3 = 6 CLOSED = \HB™ NVRAM FREE SPACE COMPACTON OBEN = PEREORW NVRAM FREE SPACE COMPACTION (NOTE. "SWITCH MUST BE CLOSED BEFORE ENTER NG ‘CONFIGURATION MODE) 53 - 7 CLOSE = NHST NVRAM N-TALZATION OPEN = NTALZE WyRaw (HOTE SWITCH MUST BE CLOSED BEFCRE ENTER NG CONFIGURATION MGOE) SS = 8 CLOSED = PRWARY CONTROLER SPEN w SECONDARY CONTROLLER 5 SMTCH S4 SELECTS STATION NK BAUD RATE C1 = 5000 SAUD. 2% 40000 BAUD 5 xU40 WT O.PSHUNT NSTALLED (NO STRAPS BROKEN) ENABLES RS 232 PORT XUS1 WITH DIPSHUNT S_NSATALLED (NO STRAPS BROKEN) ENABLES REDUNDANCY UNK ETHER DPSHUNT 5 NSTALLED N xu40 OR XU41 BUT NoT BOTH 7 U7 wm OpSUNT NSTALLED (NO Smaps BROKEN) ENABLES GBC '10' ACT AS WASTER CONTROLLER 1/0 ON XP) sus XU47 WT NO DPSHUNT STALLED ENABLES CBC TO ACT AS SLAVE WIM NO RECT CONTROL OVER TS 70 SI S2 S83 s4 | xuso | xuar [xu42 alsle] eh] 213]«]5]6] 718 61702 w/our| nour] n/our} 4 xo] fh] bl2)9]9}0)0)0 I SEE SHEET 78 FOR FUTHER DETALS REFER TO PRODUCT NSTRUCTION E92~500—3 FOR FUTHER NFORMATION 35 8/A00542 NETWORK 90/NF 90 JAL760273C SHT 75 4 ICAD FILE— 76027375 \) see coktex BATCH COMMAND CONTROLLER MODULE SWTCH SETTNGS (CON 7) {ANALOG BOARD) , it at “gb” a | “ANALOG BOARD ' ‘SPTION. ‘conmro.| sernnc| descr pron ‘ANALOG NPUT No 1] $3-1 [OPEN [FOR VOLTAGE NPUTS | $324 __|Closen |For cuarenr Series | ANALOG NPUT No 2/ $3-2 | OPEN [FOR VOLTAGE NPUTS S3=2_| cLoseo [FOR CURRENT NPUTS ‘ANALOG NPUT No S| S3-3 | OPEN [FOR VOLTAGE NPUTS s3-3 | cuosep [For CURRENT NeUTS: ~ ‘ANALOG _NPUT No 4] ANALOG NPUT No 5] ANALOG NPUT No 6 "ANALOG BOARD st $8, 2. $6, ay 7 MMP TION. s2sh234s67h2sro2zese 712 3h 234567 For voutace neut | ca0jocooccalcodocooosdccojocaccod a5 Vac) rom cunt Pur cacjecooaoacodccocoacleaoccaaoed| (4-20 mA} Fon Twemuacoure ccclocecooolcclocecoodoccacccood| | FoR Swe 87D ceeloooocecloccdocooccdoccloococcd| cecloooccecioccococcedoccooacced { ecelocooooa|occdococoadocclocacoad| SEE SHEET 77 FOR FUTHER DETALS REFER TO PRODUCT NSTRUCTION £92-500-3 FOR FUTHER NFORWATION AL7602736 SHT.76 oan GAD FILE 76037376 Se\n ceks y- io : NETWORK $0/NF 90 =~ BATCH COMMAND CONTROLLER MODULE SWITCH SETTNGS (CON T) (DG TAL BOARD) wey "Tt u 3 ve toh aoe ves Notes "| SWITCH St SELECT /O ADDRESS (1 = LSB) ADDRESS 0 S NVAUD 2 SWITCH $2 SELECTS, DERQUNCE GPmION FOR 2 PULSE, NPUTS OPEN PULSE. NEUT No tb SwiTEH DEBOLNCE © (50 Kita MAK, FREQUEN cose Kitist’ NeUT wot Swen OEBOUNCE ACTIVATED (40 Hz MAX FREGUENCY) S2 -2 OPEN = PULSE NEUT No 2 NO SWITCH DEBOUNCE $0 a UA Ie ouESC crosen'? Butst“NeUT No 2 SWTCH DEBOUNCE ACTYATED (40 Hz MAX FREQUENCY) 3_SWITOM $4 SELECTS ANALOG OUTPUT OPTIONS ETON, CONTROL] SETENG | DESCRPTION ANALOG GUTRUT Nov] S41 | OPEN ‘PROVIDES CURRENT cuTPUT CLoseo | Paowoes vowrace SuTHU? se=2 | OPEN WES £35 5 (SP EY SR PEE Closeo | VEL 075 v (+S) OUTPUT FOR POWER UP Sa=3 | OPEN WOLDS LAST ANALOG OUTPUT VALUE ON Wer tMeur cLosed | GOES TO POWER-UP VALUE SET BY 4-2 GR wer TweOUT ANALOG OU-PUI NO 2] Sane | OPEW BROVDES CURREN- Ou Pu CLoseo _| PROMDES VouTAGE OUTPUT Sa-5 | OPEN YELDS $25 v (105% OUTPUT FoR POWER UP Ctoseo | YeLos 075 v (Sa) CuTPUT FoR POWER UP S4=6 | OPEN HOLDS LAST ANALOG OUTPUT VALUE ON Mer tMeour cxosen | S065 TO FOWER-UP VALUE SET BY S4—5 BR maou SEE SHEET 78 FOR FUTHER DETALS 1@ }@ 97600 006 NETWORK 80/4F 90 AL7602738 SHT 77. i \ CAD FLE— 76027377 No ac oe BATCH COMMAND CONTROLLER MODULE SWITCH SETTNGS (CON'T) (OG TAL BOARD) 4 JUMPER v1 SELECTS VOLTAGE MODE OPERATON FOR DGTAL NPUT No 1 wt 1 2 = AC OPERATON 2-3 = OC OPERATION 5 JUMPER J2 SELECTS VOLTAGE MODE OPERATON FOR DGITAL NPUT No 2 J2 1-2 = AC OPERATION 2-3 = DC OPERATON 6 JUMPER J3 SELECTS THE AMPL TUDE RANGE FOR PULSE NPUT No 1 31-2 = VALD LOW -500 V TO BO VALD HGH = 140 V 70 300 V 2-3 = VALO LOW = 500 VTO23V VALD HGH - 3.5 V TO 80 V 7 JUMPER J& SELECTS THE AMPL TUDE RANGE FOR PULSE NPUT No 2 v4 1-2 = VAUD LOW = 50.0 V TO 6.0 v VALD HGH = 140 V 70 30.0 V 2-3 = VALO LOW = -SO0 Vv TO23V VALD HGH = 3.5 VT0 BOV SHEET 79 FOR FUTHER DETALS. REFER TO PRODUCT NSTRUCTON E92—500-3 FOR FUTHER NFORMATON @@z ES ayzeoa7se sun 78 WL \ HeTwoes Coane 36: illey, [CAD FILE— 76027378 97600 f BATCH COMMAND CONTROLLER MODULE SWTCH SETTNGS (CON 1) (MANUAL CONTROL BOARD) ores 1 SMTCH $1 SELECTS MANUAL CON"ROL OPTON For DG7AL OV HUTS S11 OPEN ~ OUTPUT HOLD LAST VALUE UPON CPU FAILURE OR REMOVAL ‘CLOSED = OUTPUT CAN BE CONTROLLED BY DEFAULT 'SWTCHS ($2) UPON CPU FAILURE OR REMOVAL si-2 UNUSED 2 SWITCH 82 SELECTS DEFAULT FOR OGITAL OUTPUTS (St=1 CLOSED) S2-1 OPEN = DGTAL OUTPUT 1 iS OFF CLOSED = OGTAL OUTPLT 1 15 ON 82-2 OPEN = DGITAL OUTPUT 2 S OFF CLOSED - OGTAL OUTPUT 2 S ON 3. SWITCH $3 SELECTS ANALOG OUTPUT MANUAL CONTROL 'S3 OPEN (SMITCH NOT DEPRESSED) = OUTPUTS WiLL DEFAULT TO SWTCH SETTINGS ON DG TAL BOARD CLOSED (SWITCH DEPRESSED) = DEFAULT OUTPUTS OVERRIDDEN BY SCREWOR VER ADJUSTMENTS UPON (CPU FAILURE OR REMOVAL, REFER TO PRODUCT NSTRUCTON £82 500-3 FOR FUTHER NFORMATION — @ @ sl nerwork so/xr oo [BIA 97600 ORS Rite WO SA eter MMFPOCT TERM NAT ON UNIT 2 S S a0 = woo z z on sl\e =& »oO # ns-aas port |e7 ee Ps eee ee 5 5 & “oo a aco «co wee 6 “EH z = are rol) NTMPO1 Notes 1 1 AND _J2 SELECTS THE NTERFACE MODE OF THE MFP ‘Ji_CONTROLS P6 AND J2 CONTROLS PS FOR STANDARD DCE, NTERFACE TO AN BM COMPUTER CONFIGURE ut AND/OR 2 AS” FOLLOWS Seat ze ee FOR DTE NTERFACE CONF GURE J1 AND/OR J2 AS FOLLOWS: ee Be 30-06 4005 SEE SHEET 81 FOR FUTHER DETALS NETWORK 90/INF 90 |AL.7602738 SHT. 80 CAD FILE— 76027380 NTMPO1 TERMNATON UN T CON’T 2 JS TO J10 ENABLE THE HANDSHAKE FOR THE COMMUN CATION LNK "ANO MUST BE SET TO MATCH EQUPMENT BENG USED JUMPERS NSTALLED (TO +12 SUPPLY) CORRESPONDS TO LOGO 12 A \/-_—{i er POSE a DIR 3 ub NSTALLED CONNECTS P6'S CABLE SHIELD (© 1) TO CHASES GROUND Ja NSTALLED CONNECTS PS'S CABLE SHELO (PN 1} TO CHASSIS GROUND 4 JUMPER POSTS LABELLED J11 AND J12 ARE PROVIDED TO STORE JUMPERS USED BY J3 THROUGH 10. 5 18 JUMPERS NSTALLED_ ACROSS PNS 1 AND 2 SELECTS RS—485 OPERATON VA Pz (PS IS NOW NACTIVE AND THE JUMPERS ASSOC ATED WITH T HAS NO EFFECT ON P7 P7 HAS A FXED PNOUT) JIS NSTALLED CONNECTS P7 CABLE SHELD (PN 1) TO CHASSS GROUNO 7 JUMPERS JI4 THROUGH J17 MUST BE LEFT _N THE FACTORY NSTALLED POSTON (GUMPERS” NSTALLED ACROSS PNS 1 AND 2) aI RPT PTR] APO WO ssl NETWORK 90/NF 90 SOMES Bf Qh scletec 97600 006 IMMFPOC TERMINATION MODULE essssaazal| = ae PS oe eg oF 8 lz & HO, Le i S = com se ve OO = ys be = mow wee ra Co ws wz | ze 5 cons : ol 8 = ‘co é = wn o P7 BP 8 CD wto5? a] 8 oh B« =i wea EG, |] ® fLccrcomee SPARE SPARE 2 = NIMPO1 NOTES 1 JI ANO_J2 SELECTS THE NTERFACE MODE OF THE MFP. SI CONTROLS P& AND U2 CONTROLS PS FOR STANDARD DCE NTERFACE TO AN ‘BM COMPUTER CONF GURE. I AND/OR 2 AS FOLLOWS. wz 3 a 1 z SEE SHEET 83 FOR FUTHER DETAILS. CAD PIES Feskhe WV cle be NETWORK $0/NF 90 wo 97600 006. NTMPO1 TERM NATION MODULE (CON’T) Fon OTE NTERFAGE CONRURE st AND/OR J2 AS FOLLOWS wey ee 2 WS TO JNO ENABLE THE HANOSHAKE, FORTHE COMMUN CATON LN “AND MUST BE SET TO MATCH EQU PMENT BENG USED JUMPERS NSTALLED (10 #12 SUPPLY) CORRESPONDS TO LOGC“O way | Jere 2 6] 582-05 BS Homes lssvio 1 - Je yoe{ J 3 + 3 JUMPERS POST LABELLED 11 AND J12 ARE PROVIDED TO STORE THE JUMPERS NOT USED BY JS THROUGH Wid 4 J18 JUMPER NSTALLED ACROSS PNS 1 AND 2 SELECTS RS~485 OPERATON iA 7 (P5 SNOW NACIIVE AND THE JUMPERS ASSOC ATED WITH T HAS NO EFFECT ON P7: B7 HAS A FXED PNOUT.) 5 JI3 NSTALLED CONNECTS P7's CABLE SHIELD (PN 1) TO CHASSS GROUND JUMPERS J14 THROUGH J17 MUST BE LEFT N THE FACTORY NSTALLED POS TON (UMPERS” NSTALLED ACROSS PNS 1 AND 2.) 73 conerror ae ae a no Po Ram OTE ROOT PCR] IT x «le [x [™ i] Kay itt] apa sout arr| wart] wane NETWORK 90/NF 90 97600 005, \L760273C SHT 83. -. \ Ckoriee Jeoz7ses \N\> SA cee ANALOG CONTROL STATON SWITCH SETTNGS NOTES 1 SWITCH SET ‘OPEN" LOCC 1 2 S1 * OPEN ENABLES D AGNOS™CS CLOSE FOR NORMAL OPERAT ON S12 OPEN FOR 40K SAUD SER AL COMMUN CATONS, CLOSED FOR 5k BAUD SER AL COMMUN CAT ONS, 31-3 TO 8 SELECTS STATON ADDESS (8 LSB) 3.52 - 1 OPEN ENABLES AUTO BYPASS CLOSED DSABLES AUTO BYPASS S22 OPEN FOR REVERSE 00 OUTPUT CLOSED FOR NORMAL 00 OUTPUT 52 - 3 OPEN ENABLES ELECTRC OR VE CLOSE _DSABLES ELECTR C OR VES 4 S3 SELECTS DSPLAY OPTONS FOP STAND ALONE DSPLAY OPT ONS OPSWICH S3_ | BAR GRAPH OSPLAY 1 ONLY DSPLAY OPTONS AVA LABLE WHEN ELECTRC ORVE OPTON wren Pos TONS ie VAR. OUT ‘S ENABLED o-oo | gang Bhan wa m 2 VAR SWITCH TOGGLES THE D-SPLAY ae ae ae FROM At TO 00 a NA zi MA ra Ma ay # ut @@s SEE SHEE” 85 FOR MORE NFORMA™ ON Ball s ijley oe NETWORK 90/NF 90 ley 3) cad Fie~ 76027384 \\\_.Soc\ use y = ANALOG CONTROL STATON SWTCH SETTNGS ( S4+1 OPEN ENABLES SQUARE ROOT (ON ANALOG NPUT 1 ONLY) CLOSED D SABLES SQUARE ROOT (GN ANALOG NPUT T GNLYI $4-2 TO 4 SELECTS NORMAL MODE DSPLAY OPTIONS DSPLAY OPTONS: DPSWITCH S& BAR GRAPH 0 SPLAY ISMTCH POS TIONS 3 VAR OUT ___seT o Pv a P. i PV AY op oa a 4} LLldetelo}. -}-lo}o|-|-lofo fo = Py [AUL ON [SF c AZ| oO SP. 7 AD AL SE o AQ [BANK | SP a ALE ON] SP S4~5 TO 8 SELECTS BYPASS MODE DSPLAY OPTIINS DSPLAY OPTONS. OPSWTCH S4 BAR GRAPH D SPLAY STC POS TIONS 678 vaR___QUT __seT. oo 00" | Bank [At N 001 atank [00 NA oO tO Ad BO. NA OO 20 ‘D0 NA I oo 16) AG NA | Oo Ar AT NA [a aE AZ| 00- NAL | Ot TEE AT NA | roe 9 PuMrFe) | 00 NA | 7 BLANK | BLANK [NA SEE SHEET 86 FOR MORE NFORMATON NETWORK 90/N 90 a: Te07784 947.25 ARBPORA eT Es WA SA be 97600 006 ANALOG CONTROL STATON SWTCH SETTNGS (con't) & JP1 TO JP3 SELECTS CONTROL STATON OPTONS ren ‘enon jameen | Sermc| optiow stars WANGAL OVERROE | PP ENABLE WANUAL OVERR OE SwTGH swrcn DSABLE WANUAL OVERR OE SmICH ELECTR DAVE | 2 Rw On ve mee MERGCOMPTTER | 3 RORMAL_CPERATON NODE _OF OPERATION] FACTORY SETTING 5 SOR Ras ny warm 2 sauce cum. vam tosrcT De con 2 RT LOENS COn SSCS Ss Mite ae neve eaten SWITCH POLES Ta] 3 41S] 775) JUMPERS (1 OR 3)/ er] 2 | 3} H sz tf 33 Sa SEE PRODUCT NSTRUCTION E96-117 FOR MORE NFOMATION NETWORK 90/NF 90 97600 006 |AL760273A SHT 86 \ cad FiE-7e027306 \\\, S\nrer tcc GATEWAY COMMUNUCATONS MODULE SWTCH SETTNGS (PLANT LOOP TO PLANT LOOP TRANSFER MODULE SWTCH SETTNG, SA, | To newory caro 94 a NGCMO2 @) [Sle To MEMORY CARD PS — NPE TOI | 1 u72_s 1 U7 8 LSS THOGOGD) (COAG (ooaNe] =—— aa) ren ‘OPEN GEN eeee woes 1 SwTO4 Set “OPEN = LoS 2. SWITCH U72 SELECTS OPERATING OPTONS 1U72=" CLOSED ENABLES ROM CHECHSUMM NG (NORMAL OPERATION) ‘OPEN 0 SABLES ROM CHECKSUMMNG (USED BY OEVELCPMENT PERSONNEL U72 2 CLOSED = R522 PORT N DCE MODE (DRECT CONNECT ONS) (OPEN = R5252 PORT N OTE MODE (MODEM CONNECTIONS) UZ 3 CLOSED = EQUPMENT SELECT OUTPUT DE~ENERG ZED ‘OPEN EQUPMENT SELECTS OUTPUT ENERG ZED (4 UNQUE EQUPMENT SELECT MAY EXST BETWEEN THE PR MARY BND SECONDARY PPT/GCM THE EQUPMENT SELECT OUTPUT IS DIGITAL OUTPUT 3 OF A DIGITAL SLAVE (MOSMOE “OSGI /02 7/03/04 AND NDSMOS, NOSOOI/02/03/08) U72. 4 CLOSED = PORT 1 OPTON NTERFACE/GATEWAY COMMUN CAT ON ‘OPEN = PORT 1 UTILITY OPTION (PORT 1 RESPONDS AS DCE WHEN T 5. ‘CONF GURED AS UML TY PORT, SET U72~4 OPEN F PORT 5 NOT USED AS A COMMUN CATION. NTERFACE ) SEE SHEET 88 FOR MORE CETALS ® network 90/n 90 [BIA S