NF10FX Standard Compressor R134a 115-127V 60Hz: Compressors

This document provides specifications for the Danfoss NF10FX standard compressor, including: 1. It is designed for use in low back pressure and medium back pressure applications with an operating temperature range of -20 to 45°F. 2. Key specifications include a displacement of 0.62 cubic inches, maximum refrigerant charge of 16.1 ounces, and motor size of 330 watts. 3. Dimensions include a height of 7.76 inches, suction connector ID of 0.320-0.327 inches, and it can be shipped on a pallet containing 80 compressors.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views2 pages

NF10FX Standard Compressor R134a 115-127V 60Hz: Compressors

This document provides specifications for the Danfoss NF10FX standard compressor, including: 1. It is designed for use in low back pressure and medium back pressure applications with an operating temperature range of -20 to 45°F. 2. Key specifications include a displacement of 0.62 cubic inches, maximum refrigerant charge of 16.1 ounces, and motor size of 330 watts. 3. Dimensions include a height of 7.76 inches, suction connector ID of 0.320-0.327 inches, and it can be shipped on a pallet containing 80 compressors.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

NF10FX Compressors

Standard Compressor
R134a
115-127V 60Hz
Data Sheet (Replaces CD.43.X4.22)

General
Compressor NF10FX Application NF10FX 105G
Connector-material Sealing Code number R134a
Blue stripe
Copper-plated steel Aluminium caps SUCTION
CONNECTOR
Copper-plated steel Rubber plugs 105G5941
5941

8309-7
Copper Rubber plugs 105G5946 Barcode on
white background DANFOSS COMPRESSORS
Green background

Application R

Application LBP/MBP
Evaporating temperature range °F (°C) LBP: -20 to 0 (-28.9 to -17.8) NF10FX
MBP: 0 to 45 (-17.8 to 7.2) 115V-60Hz
Voltage range V/Hz 95 - 135 /60
1PH

8309-8
THERMALLY
Motor type CSIR PROTECTED
Max. ambient temperature °F (°C) 110 (43) Approval mark
S = Static cooling normally sufficient
Comp. cooling at LBP: F2 O = Oil cooling
F1 = Fan cooling 1.5 m/s
max. ambient temperature 110°F (43°C) MBP: F1 (compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary

Design
Displacement cu.in. (cm3) 0.62 (10.09)
2.34" (59.5)
6.54"(166)

3
Oil quantity fl.oz. (cm ) 10.8 (320)
2.83"(72)

2.13"
27°

3.01"(78)
51°

(54)
Maximum refrigerant charge oz. (g) 16.1 (460) 47°
3
Free gas vol. in compressor housing fl.oz. (cm ) 79.7 (2360)
Weight without electrical equipment lbs. (kg) 22.0 (10.0) 4.45"(113) 4.69"(119)
5.00"(127)
D 8.10"(205)
Motor E
Motor size watt 330 C
LRA (rated after 4 sec.UL984) HST A 30.0
Cut-in current HST A 30.0
25°

35°

A B
15°

Resistance, main and start winding (77°F) Ω 1.7/5.4


3.68"(93.5)

2.97"(75.5)
4.04"(102.5)

Approvals UL984/CSA-C22.2

Dimensions 9.92"(252)
8367
8.03"(204)
Height in. (mm) A 7.76 (197) 6.70"(170)
B 7.52 (191)
Suction connector location/I.D. in. (mm) C 0.320-0.327 (8.2±0.09)
4.00"(101.6)
5.20"(132)

2.76"(70)
1.38"(35)

ø0.75"(19)
Process connector location/I.D. in. (mm) D 0.252-0.259 (6.5±0.09)
ø0.63"(16)
Discharge connector location/I.D. in. (mm) E 0.252-0.259 (6.5±0.09)
ø0.38"(9.7)
Compressors on a pallet pcs. 80
6.50"(165)
7.32"(186)

July 2003 CD.43.X5.22 1


Capacity at LBP conditions (ASHRAE) Btu/h
Comp.\°F -20 -13 -10 0 10 20 30 40 45
Comp.\°C -28.9 -25 -23.3 -17.8 -12.2 -6.7 -1.1 4.4 7.2
NF10FX 746 950 1046 1411 1854 2391 3036 3805 4240

Capacity at MBP conditions (ASHRAE) Btu/h


c
Comp.\°F -20 -13 -10 0 10 20 30 40 45
Comp.\°C -28.9 -25 -23.3 -17.8 -12.2 -6.7 -1.1 4.4 7.2 a2
NF10FX 663 845 930 1254 1647 2123 2693 3372 3756 8226
d

Capacity (EN 12900/CECOMAF) watt


Comp.\°C -28.9 -25 -23.3 -17.8 -12.2 -6.7 -1.1 4.4 7.2 dc
Comp.\°F -20 -13 -10 0 10 20 30 40 45
NF10FX 178 227 249 336 440 567 719 899 1001
b
a2
Power consumption watt
c
Comp.\°F -20 -13 -10 0 10 20 30 40 45
Comp.\°C -28.9 -25 -23.3 -17.8 -12.2 -6.7 -1.1 4.4 7.2 10 11 Start winding
NF10FX 225 250 261 302 345 391 438 487 512 12 13

Thermostat
Main winding
14
Current consumption A
Comp.\°F -20 -13 -10 0 10 20 30 40 45
Comp.\°C -28.9 -25 -23.3 -17.8 -12.2 -6.7 -1.1 4.4 7.2
M
NF10FX 3.48 3.64 3.71 3.97 4.25 4.55 4.87 5.21 5.39
Motor protector

EER at LBP conditions (ASHRAE) Btu/Wh


Comp.\°F -20 -13 -10 0 10 20 30 40 45
Comp.\°C -28.9 -25 -23.3 -17.8 -12.2 -6.7 -1.1 4.4 7.2
NF10FX 3.32 3.80 4.00 4.68 5.38 6.12 6.93 7.81 8.29

EER at MBP conditions (ASHRAE) Btu/Wh


Comp.\°F -20 -13 -10 0 10 20 30 40 45
Comp.\°C -28.9 -25 -23.3 -17.8 -12.2 -6.7 -1.1 4.4 7.2
NF10FX 2.95 3.38 3.56 4.16 4.78 5.43 6.15 6.93 7.34

COP (EN 12900/CECOMAF) W/W Accessories


Comp.\°C -28.9 -25 -23.3 -17.8 -12.2 -6.7 -1.1 4.4 7.2 Devices Fig. NF10FX
Comp.\°F -20 -13 -10 0 10 20 30 40 45
NF10FX 0.79 0.91 0.95 1.11 1.27 1.45 1.63 1.84 1.95 Star ting relay (protector incl.) 117U4129
a2
Protector 3/4" Texas Instr. MRT22AFZ-6
Test conditions ASHRAE (LBP) ASHRAE (MBP) EN12900/CECOMAF
Condensing temperature 130°F (54.4°C) 130°F (54.4°C) 55°C (131°F) Star ting capacitor 320 µF c 117U5022
Ambient and suction gas temp. 90°F (32°C) 95°F (35°C) 32°C (90°F) Cover b 117U1021
Liquid temperature 90°F (32°C) 115°F (46°C) 55°C (131°F)
Fan cooling F1, 115V 60Hz Cord relief d 117U0349
Cord relief for capacitor dc 117U0349
Mounting accessories Ø in. (mm)
5
Bolt joint for one comp. /8 (16) 118-1946
3
Bolt joint for one comp. /4 (19) 118-1949
5
Snap-on for one comp. /8 (16) 118-1947

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2 CD.43.X5.22 July 2003

You might also like