0% found this document useful (0 votes)
1K views93 pages

B33 - MAKER Manual Sliding Fire Doors PDF

This document provides instructions for installing and maintaining A60 sliding fire doors on Ship B33. It includes safety instructions, mounting procedures, operational descriptions, instructions for installing the fire door control system, recommended service intervals and items to check, including testing safety strips weekly and lubricating door seals monthly. Drawings and equipment lists are also included.

Uploaded by

Iustin Onosa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views93 pages

B33 - MAKER Manual Sliding Fire Doors PDF

This document provides instructions for installing and maintaining A60 sliding fire doors on Ship B33. It includes safety instructions, mounting procedures, operational descriptions, instructions for installing the fire door control system, recommended service intervals and items to check, including testing safety strips weekly and lubricating door seals monthly. Drawings and equipment lists are also included.

Uploaded by

Iustin Onosa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 93

4.11.

2008 B33

USER’S MANUAL

A60 sliding fire doors


Ship B33

Delivered 2008

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 1/22
4.11.2008 B33
Table of Contents

SAFETY INSTRUCTIONS 4 

Safety Strip and Door Handle 4 

Cables and Sensors 4 

Power On 4 

MOUNTING AND WELDING PROCEDURE FOR A-60 SLIDING DOOR 5 

LIST OF MOUNTING DRAWINGS 5 

SERVICE INTERVALS AND SERVICE ITEMS 6 

Doors, which are normally kept open 6 


Service approx. 2 times a year 6 
Service once a week 6 

Sealing of the SWT sliding doors 6 


Service every month 6 

OPERATIONAL DESCRIPTION 7 

Normal Door Operation 7 

Mechanical Operation of the Safety Strip 7 

Automate operation during an Emergency Situation 7 

Manual operation during an Emergency Situation 8 

Emergency opening device 8 

Electrical Moment Detection as “Safety Strip” 8 

Hold Back System 8 

Service Hatches 9 

INSTRUCTIONS FOR INSTALLATION OF FIRE DOOR CONTROL SYSTEM


10 

Main Power Supply 10 

Motor controller 10 

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 2/22
5.11.2008 B33
Electric Motor 10 

UPS system (Batteries) 10 

Latch Solenoid 11 

Limit Switch 11 

Buzzer 11 

Temperature sensors 11 

Test running 11 

Run Adjustments 12 

Manual Setting of Parameters 13 

Recommended Parameters 14 


Normal Open sliding doors 15 

FAULT FINDING 16 

DRAWING LIST 18 

COMPONENT AND SPARE PART LIST 19 

DATA SHEETS OF THE MAIN CONPONENTS 20 

DECLARATION OF CONFORMITY 21 

TYPE APPROVAL CERTIFICATES 22 

ELECTRIC FIRE DOOR CONTROL SYSTEM 22 

A-60 SINGLE LEAF SLIDING, SEMI WATERTIGHT DOOR 22 

A-60 SINGLE LEAF SLIDING DOOR 22 

QS-CERTIFICATE OF ASSESSMENT-EC 22 

DOOR LIST 23 

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 3/23
4.11.2008 B33

SAFETY INSTRUCTIONS

Safety Strip and Door Handle

It is very important to check safety strip regularly, once a week.


The safety strip will stop the door closing and reverse the
movement to opening when encounting an obstacle. Each door
has two safety strips. Test each safety strip individually. Test
also the open and close functions of the door handle (pull lever
in both directions while door moves).

Cables and Sensors

Damage to the cables or sensors have an adverse effect on the


closing and opening functions of the door. A severe damage will
switch the door into manual operation mode.

Power On

When you connect the door control system for the first time on,
pull the door leaf into the middle position and disconnect the
motor. In this way you will prevent unwanted movements. Test
all sensors. Connect the motor and check that door moves in
right direction. Green motor led to open direction and orange to
close direction.

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 4/22
4.11.2008 B33

MOUNTING AND WELDING PROCEDURE FOR A-60 SLIDING DOOR

Before mounting make sure that the size of bulkhead opening is


in accordance to the drawings. Note the final heights of the
flooring/sill.

Make sure that the bulkhead under the vertical and horizontal
parts of the frame is plumbed and faired.

Follow instructions of mounting drawings while installation and


welding works.

LIST of MOUNTING DRAWINGS

Drawing number / Description

mounting clarifications Clarifications of measurements


mounting frame 1/4 Cut-out dimensions
mounting frame 2/4 Frame preliminary fixing
mounting frame 3/4 Frame mounting warnings
mounting frame 4/4 Frame welding
mounting single Door plate mounting
clearances single Clearances
mounting SWT Door plate mounting
clearances SWT Clearances
A60 sliding door when A>1500 LA60WeO_ab
mounting double Door plate mounting
clearances double 1/2 Clearances
clearances double 2/2 Hoseport double
mounting LT Need of insulation on the bulkhead

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 5/22
4.11.2008 B33

SERVICE INTERVALS AND SERVICE ITEMS

Doors, which are normally kept open

Service approx. 2 times a year


• apply grease onto the slide rails
• check the sliding rollers
• check the door stopper
• check the functioning of the safety strip and oil the safety strip
rollers
• check the functioning of the handles and latch
• check the tightness of the screws
• check the cables
• check the latest date for use of the batteries

Service once a week


• check the functioning of the safety strip
• check the batteries

Sealing of the SWT sliding doors

Service every month

Important: Correct lubrication improves on the closing and


opening times of the door

• visual inspection of the rubber gasket


• grease the gasket (all around the door) with vaseline grease
or silicone spray in the back part of the door
• close and open the sliding door 5 times to ensure uniform
lubrication of the gasket
• remove and clean housing of foldable seals
Note: before cleaning the seal housing the power of the door
must be switched off

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 6/22
4.11.2008 B33

OPERATIONAL DESCRIPTION

Normal Door Operation

Doors which are normally open, can be closed either by remote


control from the wheelhouse or the local door release switches
mounted on both sides of the door. The alarm will sound for 5-
10s before the door begins to close when released from the
wheelhouse. The alarm will cease when the door is totally
closed.

If the door is closing, and the safety strip mounted on the side of
the door meets an obstacle, the door is immediately stopped and
re-opened. The opening distance is according IMO’s regulation
< 1000 mm.

Mechanical Operation of the Safety Strip

A sensor mounted inside the door handle is actuated by the


movement of the safety strip when touched, or by the action of
pulling on the door handle towards the open position. The door
opens for a set duration.

Automate operation during an Emergency Situation

The operation is the same as in normal operation with the


following additional functions.

If the power supply is interrupted, the batteries provide an


accumulated power supply. The capacity of batteries is
calculated to allow the door to be opened and closed at least 10
times during a 3,5° heeling (SWT-doors with a 15° heeling)
within 36 hour.

When a door is held open electrically , the door will close


automatically after one minute continuous black out or if voltage
level of batteries drops below 30% of its capacity or ambient
temperature is higher than 75°C. The safety strip and the door
handle functions remain operational. When the battery voltage

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 7/22
4.11.2008 B33
level is below 10VDC (nom. 24VDC) or temperature is over
300°C the system is shout down. The door is kept in the closed
position by means of a latch and it is capable of being used
manually.

Manual operation during an Emergency Situation

Malfunction of the control system or the main power supply may


turn the door to manual operation. Manual operation means that
the control system does not help or disturb door movements.
Person who wants to go through closed door has to open the
door by door handle with manpower After passing the door it
should be closed again manually. The latch of the door lock will
keep the door closed even if the ship is rolling.

Emergency opening device

Semi water tight doors has been equipped with emergency


opening device (because of the water tight seals of the door).
With leaver (emergency opening device), located both sides of
door leaf, the door can de opened 200 mm. Rest can be
operated with door handle with manpower (seals does not
disturb moving).

Electrical Moment Detection as “Safety Strip”

System is equip with moment detection. While door is move


(open or close direction) and current of motor increase suddenly
e.g. door meets an obstacle, the door is immediately stopped.
After short interval door try move again in original direction.

Hold Back System

When door is in open position and ship is rolling the hold back
function keeps door in open position. The system investigate
force and gives needed current to the DC motor to keep door in
open position. The system do not need separate door magnet.

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 8/22
4.11.2008 B33
Service Hatches

The following components require service hatches if they are


behind wall panelling: connecting box, electric motor, indication
sensors, belt rollers.

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 9/22
4.11.2008 B33

INSTRUCTIONS FOR INSTALLATION OF FIRE DOOR CONTROL SYSTEM

Before you start to install the system, make sure that door can
move freely in the slide rail and that the door can be closed
properly.

Main Power Supply

Power supply from the ship’s side is 220-230VAC 50/60Hz,


30VA according to drawings User_LA60e_el1 and
User_LA60e_lay3. Follow safety instructions when connecting
electricity to system. On the surface of the controller is the main
switch. Before service works turn system off.

Motor controller

The motor controller EL2001m (electric board) is fitted to the


isolated control box see drawing User_LA60e_lay1. The box
should be locate at the same side of the bulkhead as the door
see drawing User_LA60Se_ab_0001. Used versions of
hardware is v7.2 and software is v8.1.

Electric Motor

The motor can be connected to the front or back side belt roller
see drawing User_LA60e_el5. Power of the motor is 90 Watt.

UPS system (Batteries)

Two maintenance-free valve regulated lead-acid batteries are


installed inside the control cabinet see drawing
User_LA60e_lay1. The batteries must be change interval of 8
year. Batteries guarantee 36 hour uninterruptible power supplies
for control unit and 10 times movement. Or continuous
movement up to 3 hours for door.

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 10/22
4.11.2008 B33
Latch Solenoid

The latch solenoid is installed inside the door handle see


drawing User_LA60Se_ab_0003. Please note that final
adjustments of latch should be carried out after the power is
connected to the system

Limit Switch

Door close, safety strip and door handle sensors are installed
inside the door handle see drawing User_LA60Se_ab_0003.
Door open sensor is locate at the back side of the door see
drawing User_LA60Se_ab_0002. Please note that final
adjustments of sensors should be carried out after the power is
connected to the system.

Buzzer

The buzzer is installed inside of the door handle.

Temperature sensors

All doors are equipped with one PT100 temperature sensor


which is located above control cabinet. The system is also
provided with bi-metal thermostat which (300°C) is inside motor
connecting box.

Test running

While testing you do not need out side electrical supply. The test
can be carry out with batteries.

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 11/22
4.11.2008 B33

Run Adjustments

The door should work with factory settings. If you need adjust
parameters, it can be made it manually by the sliding door
controller as follow see also drawing User_LA60e_lay3 or with
computer and fire door control program.

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 12/22
4.11.2008 B33

Manual Setting of Parameters

Parameter adjustments can be made only by authorised person.


Choose parameter witch you want to adjust by turning
“parameter select” switch. “Parameter set” led is red in
parameter setting mode and green in normal operation mode.
Drive the door only when parameter setting led is green.
Led indicators 1..9 (Latch solenoid .. Temp 70°C) indicates value
of chosen parameter in parameter set mode (tens are shown by
continuous light and ones by blinking light).

Parameter: Range: SOLAS:


1 = Opening speed 0%-100% 0.1-0.2m/s
2 = Closing speed 0%-100% 0.1/0.2m/s
3 = Opening time by handle 0.1-25.5 s
4 = Opening time by safety strip 0.1-25.5 s less than 1m
5 = Closing delay by local switch 0.1-25.5 s
6 = Hold back force when healed 0%-100% 3.5° (15°SWT)
7 = Motor max. current 0.0-10.0 A
8 = Moment detection time 0.01-2.55 s
9 = Delta moment current 0.05-5.00 A
A = Not in use -
B = Lock force 0%-100%
C = Not in use -
D = Mode Switch 1 (Activating action mode, underlined are
factory settings)
1 -> ON/OFF = Battery charge/only when door is stopped
2 -> ON/OFF = Continuous buzzer/piping sound
3 -> ON/OFF = Hinged/Sliding fire door
4 -> ON/OFF = Fire wall/Fire door
5 -> ON/OFF = Sound alarm when moving/closing
6 -> ON/OFF = 5s delay with local release/not delay
7 -> ON/OFF = Invert/not invert errors
8 -> ON/OFF = Disable horn test/test active
E = Mode Switch 2 (Activating action mode, underlined are
factory settings)
1 -> ON/OFF = Hold back force ON/OFF
2 -> ON/OFF = Normal Closed door/Normal Open door
3 -> ON/OFF = SWT door/Classic fire door
4 -> ON/OFF = Remote 1=Light beam sensor/normal
5 -> ON/OFF = Negative/Positive remote open
6 -> ON/OFF = Black Out Detection ON/OFF

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 13/22
4.11.2008 B33
7 -> ON/OFF = Moment Detection ON/OFF
8 -> ON/OFF = Remote 2 =Remote 1 / Lock command
F = Mode Switch 3 (Activating Input / Output, underlined are
factory settings)
1 -> ON/OFF = Latch Solenoid active/inactive
2 -> ON/OFF = Alarm Buzzer active/inactive
3 -> ON/OFF = Lock Solenoid active/inactive
4 -> ON/OFF = Car Ramp sensor active/inactive
5 -> ON/OFF = Handle Open sensor active/inactive
6 -> ON/OFF = Handle Close sensor active/inactive
7 -> ON/OFF = Close Limit sensor active/inactive
8 -> ON/OFF = Open Limit sensor active/inactive

You can change value by pushing buttons (“Increment” or


“Decrement”) on the surface of the motor controller while system
is active and door not move. When setting is right, new value will
be registered by turning selection switch to other position.
Factory settings can recall when selection switch is “0” by
pushing both buttons “Increment” and “Decrement” two seconds.
Turn selection switch always in position “0” after adjusting, other
ways led indicators indicates value of parameter not states of
sensors.

Recommended Parameters

Parameter adjustments must be carry out for every door type.


Note: Final settings might not be same as factory settings.

Use following parameter value to ensure wanted functions.


Differences between door types are made with parameters:

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 14/22
4.11.2008 B33

Normal Open sliding doors

Parameter: Value:
1 = Opening speed 50
2 = Closing speed 37
3 = Opening time by handle 30
4 = Opening time by safety strip 30
5 = Closing delay by local switch 5
6 = Hold back force when healed 66
7 = Motor max. current 52
8 = Moment detection time 7
9 = Delta moment current 14 (SWT 25)
A = Not in use -
B = Lock solenoid holding force 5
C = Not in use -
D = Mode Switch 11000010
:1 -> ON = Battery charge active
:2 -> ON = Continuous buzzer
:3 -> OFF = Sliding fire door
:4 -> OFF = Fire door
:5 -> OFF = Sound alarm closing
:6 -> OFF = not delay with local release
:7 -> ON = Invert errors
:8 -> OFF = Horn test active
E = Mode Switch 2 10000110
:1 -> ON = Hold back force ON
:2 -> OFF = Normal Open door
:3 -> OFF = Classic fire door / ON = SWT door
:4 -> OFF = Remote 1=normal
:5 -> OFF = Positive remote control
:6 -> ON = Black Out Detection ON
:7 -> ON = Moment Detection ON
:8 -> OFF = Remote 2 = Lock command
F = Mode Switch 3 01001111
:1 -> OFF = Latch Solenoid inactive
:2 -> ON = Alarm Buzzer active
:3 -> OFF = Lock Solenoid inactive
:4 -> OFF = Car Ramp sensor inactive
:5 -> ON = Handle Open sensor active
:6 -> ON = Handle Close sensor active
:7 -> ON = Close Limit sensor active
:8 -> ON = Open Limit sensor active

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 15/22
4.11.2008 B33

FAULT FINDING

Possible error situations: (all the error situations will reset


automatically after the error is disappeared). These error
situations have been indicated on the circuit board cover with
red led light (15 different errors).

1st Circuit boards software/hardware error


-machine will switch to manual operation, program will stop
-error alarm, 220VAC alarm, 24VDC alarm

2nd Black out, 220VAC missing


-after 1min. continuous power failure door will close.
-batteries will ensure all the local functions for 1½ days. The
door will close automatically when battery capacity drops below
30% of full capacity.
-error alarm + 220 supply alarm

3rd Batteries will get dry etc, 24 VDC missing


-door will switch to manual operation, if 220VAC also missing.
Other vice the system will keep in function via 220 supply line.
-error alarm + battery alarm

4th Motor in short circuit or disconnect


-door will switch to manual operation
-error alarm

5th Open limit sensor broken/disconnect


-door will close automatically and switch to local control, moment
acquisition will stop the door when it is in open position.
-error alarm, door open error

6th Close limit sensor broken/disconnect


-door will stop to close position with moment acquisition based
on motor’s current, other functions based on moment acquisition
will not work.
-error alarm, door close error

7th Lock solenoid in short circuit/disconnect (option)


-door can not be locked
-error alarm

8th Handle’s open sensor broken/disconnect


-when door is closed it is manual operated so that it can be
opened manually, does not effect to other functions

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 16/22
4.11.2008 B33
-error alarm

9th Handle’s close sensor broken/disconnect


-door does not close from handle, does not have effect to other
functions of the door
-error alarm

10th Latch solenoid in short circuit/disconnect


-door does not open automatically by remote control
-error alarm

11th Buzzer in short circuit/disconnect


-buzzer does not work, does not have effect to other functions
-error alarm

12th Temperature >70°C


-door close automatically, error reset when temperature is <50°C
-error alarm

13th Temperature >300°C


-all the power supply will be cut off, restart manually, when
temperature is < 50°C
-error alarm

14th Temperature sensor in short circuit/disconnect


-function as in temperature >300°C

15th The door will be driven to close or open direction for 1 min
without any sensor information (door is jammed or tooth
belt/chain is broken, etc)
-motor keep on driven to original direction
-error alarm + Door closed / Door open alarm depending on
direction of drive

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 17/22
4.11.2008 B33

DRAWING LIST

Drawing number / Description

User_LA60Se_ab_0001 A60 sliding door, single leaf


User_LA60Se_ab_0002 Profile guide and supports, single door
User_LA60Se_ab_0003 Handle actuators, single
User_LA60Se_ab_0004 Bowl and handle
User_LA60Se_ab_0005 Hoseport, single
User_LA60Se_ab_0006 Safety edge, single
User_LA60Se_ab_0007 Door leaf bottom edge tighter
User_LA60Se_ab_0008 Tail
User_LA60Se_0128 Motor assembly

User_LA60We_0052AE SWT motor assembly A>1500


User_LA60We_0053 SWT rack assembly A>1500
User_LA60We_ab_0001 A60 sliding door, SWT
User_LA60We_ab_0002 Profile guide and supports, SWT
User_LA60We_ab_0003 Handle actuators, SWT
User_LA60We_ab_0004 Guiding bearing
User_LA60We_ab_0005 Safety edges, SWT, double
User_LA60We_ab_0006 Emergency opening device
User_LA60We_ab_0007 Foldable sill beams

User_LA60e_lay1 Control box


User_LA60e_lay3 Sliding door controller
User_LA60e_el1 Electric diagram
User_LA60e_el2 Electric cables
User_LA60Se_el3 Electric connections of the single leaf
User_LA60We_el3 Electric connections of the SWT

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 18/22
4.11.2008 B33

COMPONENT and SPARE PART LIST

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 19/22
4.11.2008 B33

DATA SHEETS of the MAIN CONPONENTS

Component: Tn: Type:

DC geared motor pn102 M1 / 808995


Close limit sensor pn217 IFS201
Open limit sensor pn224 IF5719
Safety strip sensors pn145 MP320XA-1M375/30PFTE
Buzzer pn144 DB-E38
Motor Controller pn226 EL2001m
Temperature sensor pn129 902004/10-390-1003-1-…
Back side socket pn139+pn195 701410 + 700210
Back side plug pn140+pn196 702610 + 700110
Door cable pn187 BiHFZP-O 8*1
Motor cable pn186 BiHFP-O 2*1
Tooth belt pn168 LL-S8M-20 STS
Battery pn127 RE5-12
Connecting terminal pn137 BK12
Belt tighter HNM98
Tooth wheel pn167 ST22S8M20

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 20/22
Inductive proximity switches
IFS201
IFB2007-ARKG/M/US
Metal thread M12 x 1
Plug and socket

Increased sensing range


gold-plated contacts

Sensing range 7mm [nf]


non-flush mountable

Electrical design DC PNP/NPN


Output normally open
Operating voltage [V] 10...30 DC
Current rating [mA] 100
Minimum load current [mA] 2
Short-circuit protection •
Reverse polarity protection / Overload •/•
protection
Voltage drop [V] < 2,5
Leakage current [mA] < 0,5

Real sensing range [mm] 7 ± 10%


Operating distance [mm] 0...5,7
Switch-point drift [% / Sr] -10...+10
Hysteresis [% / Sr] 3...15
Switching frequency [Hz] 700
Correction factors mild steel = 1 / stainless steel approx. 0.7 / brass approx. 0.5 / Al approx. 0.4 / Cu approx. 0.3
Operating temperature [°C] -25...+70
Protection IP 67
EMC IEC 1000-4-2 / EN 4kV / CD / 8kV AD
61000-4-2:
IEC 1000-4-3 / EN 10V/m, 80...1000MHz
61000-4-3:
IEC 1000-4-4 / EN 2kV
61000-4-4:
IEC 1000-4-6 / EN 10V / 0,15...80MHz
61000-4-6:
EN 55011: class B
Housing material brass special coated
active face: PBTP
Function display
Switching status LED yellow (4x90°)
Connection M12 connector, gold-plated contacts
Wiring

Remarks Conventional 3-wire pnp sensors can be replaced. In this case pin 3 (grey in the wiring diagram)
is not used.
Accessories (included) 2 lock nuts
ifm electronic gmbh · Teichstraße 4 · D-45127 Essen — We reserve the right to make technical alterations without prior notice. — GB - IFS201 — 06.03.2003
Inductive proximity switches
IF5719
IFB2004-ARKG/UP
Metal thread M12x1
Cable

Sensing range 4mm [nf]


non-flush mountable

Electrical design DC PNP/NPN


Output normally open
Operating voltage [V] 10...36 DC
Current rating [mA] 150
Minimum load current [mA] 4
Short-circuit protection •
Reverse polarity protection / Overload •/•
protection
Voltage drop [V] < 4,6
Leakage current [mA] < 0,6

Real sensing range [mm] 4 ± 10%


Operating distance [mm] 0...3,25
Switch-point drift [% / Sr] -10...+10
Hysteresis [% / Sr] 1...15
Switching frequency [Hz] 1500
Correction factors mild steel = 1 / stainless steel approx. 0.7 / brass approx. 0.4 / Al approx. 0.3 / Cu approx. 0.2
Operating temperature [°C] -25...+80
Protection IP 67
EMC EN 60947-5-2; EN 55011 class B

Housing material brass Optalloy-plated


CO-PC
Function display
Switching status LED yellow
Connection PVC cable / 2m; 2 x 0,34mm²
Wiring
Core colours
BK black

Accessories (included) 2 lock nuts


ifm electronic gmbh · Teichstraße 4 · D-45127 Essen — We reserve the right to make technical alterations without prior notice. — GB - IF5719 - / — 06.03.2003
SERIES MP320 & DERIVATIVES

MP320
SEALED MINIATURE
MICROSWITCH IP67

The MP320 miniature


microswitch is a
snap-action changeover
simple break with
the connection cable
directly over-moulded
into the housing.

GENERAL CHARACTERISTICS, TYPE MP320

Approvals :
depending on the version : CSA
Degree of protection : IP67
Class of protection : II
Micro-switch : µ
Contact-gap : 0.8 mm
Standards : EN61058-1:92 + A1:93
Frequent functioning : 50 E3
Mechanical life : 50 x 106 operations
Snap-action mechanism : Beryllium coppers leaf spring with
self-cleaning contact.
Actuators : Overall dimensions in stainless steel.
Dimensions : DIN 41 635, form A

SWITCHING CAPACITY
Depending on the material of the electrical contacts and the cross-section of conductors.

Approvals CSA

Cross-section of conductors 0.75 mm2 0.50 mm2 AWG 18

Ag contacts 6A 250VAC 2A 250VAC 6A 250VAC

Gold-plated contacts 0,1A 24VAC/DC

Microprecision Electronics SA - Tel +41 24 481 43 43 - Fax +41 24 481 43 60 - E-mail : [email protected] 30
SERIES MP320 & DERIVATIVES

* 1MPN : Chloroprene
protective sleeve

DIFFERENTIAL MOVEMENT
** 1MPSI : Silicone
protective sleeve

OPERATING POSITION
ACTUATING FORCE

RELEASE FORCE

FREE POSITION
DESIGNATION

OVER-TRAVEL

sd max. (mm)
sr min. (mm)
Fa max. (N)

Fr min (N)

Pa (mm)
Pr (mm)
MP320-1MS27/.. 3,5 1,0 27,7 ± 0,6 27,2 ± 0,3 2,0 0,10

MP320-1M/.. 3,5 1,0 50,3 ± 0,6 49,7 ± 0,3 5,0 0,10

* MP320-1MPN/..
4,0 1,0 50,3 ± 0,6 49,7 ± 0,3 3,0 0,10
** MP320-1MPSI/..

Microprecision Electronics SA - Tel +41 24 481 43 43 - Fax +41 24 481 43 60 - E-mail : [email protected] 34
SPECIFICATIONS SHEET
PRODUCT TYPE : PIEZO BUZZER
PRODUCT SERIES : DB-E38
DESCRIPTION : PZ BUZZER DUAL 24VDC FR ABS 300mmLL
COLOR : WHITE
DATE : 27.huhti.02
HANDLE BY : Joey
ELECTRICAL SPECIFICATIONS
MODEL NO. 3D3240 - L300B
OPERATING VOLTAGE RANGE ( VDC ) 6 ~ 28
RATED VOLTAGE ( VDC ) 24
* MAX. RATED CURRENT ( mA ) 35 / 20
* MIN. SOUND OUTPUT ( dBA/ 30 cm ) 100
* FREQUENCY ( Hz ) 2900 +/- 500
TONE NATURE DUAL
OPERATING TEMPERATURE (C) -20 ~ +60
TERMINAL LEADWIRE ( UL1007 , AWG#26 )
HOUSING MATERIAL FLAME RETARDANT ABS
WEIGHT (g) 28
* Value applying at rated voltage
DIMENSIONS UNIT : mm

Ref.:1-001
M. K. JUCHHEIM GmbH & Co JUMO Instrument Co. Ltd. JUMO PROCESS CONTROL INC.

Delivery address:Mackenrodtstraße 14, JUMO House 885 Fox Chase, Suite 103
36039 Fulda, Germany Temple Bank, Riverway Coatesville PA 19320, USA
Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2TT, UK Phone: 610-380-8002
Phone: +49 661 60 03-0 1-800-554-JUMO
Fax: +49 661 60 03-6 07 Phone: +44 12 79 63 55 33 Fax: 610-380-8009
E-mail: [email protected] Fax: +44 12 79 63 52 62 E-mail: [email protected]
Internet: www.jumo.de E-mail: [email protected] Internet: www.JumoUSA.com

Data Sheet 90.2004 Page 1/4

Screw-in resistance thermometers


with plug connector

■ for temperatures from -50 to +300°C


■ highly resistant to shock and vibration
■ connector locked in for reliable contact, Protection IP65

Shock-proof screw-in resistance thermometers enable temperature measurement under


pressure in motors and compressors, in plant engineering, as well as in ship building.
The connection between the protection fitting and the connecting cable incorporates a
locking system and is protected to IP65 when assembled.
The measuring insert is normally fitted with a Pt100 temperature sensor to EN 60 751,
Class B in 2-wire circuit. Versions with Pt500 or Pt1000, as well as with semiconductor or
NTC temperature sensors can be provided. With Type 902004/20 .../21, 2-wire or 4-wire
circuit connections can be selected.

Technical data
Connection Type 902004/10 plug connector with gold-plated contacts, IP5 when assembled
Type 902004/20 connector DIN 43 650, Pg9 (Type 902004/21, Pg11), max. conductor
cross-section 1.5mm2, IP65, ambient temperature -40 to +125°C.
Process connection thread, stainless steel 1.4301 / 1.4571, brass 2.0401
Protection tube stainless steel 1.4301, 6mm and 7.5mm dia. stepped down to 4mm
brass 2.0401, 7.5mm dia. stepped down to 4mm
stainless steel 1.4571, 8mm dia., pressure loading 50bar max. at 200°C
(Type 902004/20 .../21)
Measuring insert Pt100 temperature sensor, EN 60 751, Cl. B, 2-wire circuit (replaceable on Type 902004/
20.../21)*
KTY11-6 temperature sensor, 2-wire circuit
Protection IP65
Response times Type 902004/10: t0.5 = 1.2sec, t0.9 = 6sec, in water with 0.2m/sec, 4mm dia.
Type 902004/20 .../21: t0.5 = 15sec, t0.9 = 45sec, in water with 0.2m/sec, 8mm dia.
t0.5 = 23sec, t0.9 = 59sec, in oil with 0.2m/sec, 8mm dia.
Vibration strength Germanischer Lloyd Application Category D, Characteristic 2
Approvals Type 902004/20 .../21 GL Germanischer Lloyd
Accessories pocket, see Data Sheet 90.9721
mating plug for Type 902004/10 with siliconized connecting cable 0.34mm2, length 2.5m
Sales No. 90/00308880

* Note:
With Type 902004/20 .../21: short fitting lengths in conjunction with unfavorable mounting
conditions (heat conduction error) may result in the tolerance class being exceeded.

01.01/00311470
Series A 10 P +
16 A / 250 V EAN-No.
Description Part No. UL/CSA: 600 V g
4015609...

Screw terminal inserts


Female inserts
screw terminal 10
with wire protection 700 110 46 025442
0,5-2,5 mm² (20-14 AWG)

Male inserts
screw terminal 10
with wire protection 700 210 47 025510
0,5-2,5 mm² (20-14 AWG)

Crimp contact carriers


Contact carrier 10
for sleeve contacts 700 310 26 025565

Please order crimp contacts separately

Contact carrier 10
for pin contacts 700 410 27 025619

Please order crimp contacts separately

panel cut out view from termination side


Contact arrangement
B: Female inserts B S
S: Male inserts

1 6 6 1
2 7 7 2
3 8 8 3
4 9 9 4
5 10 10 5

conductor size
Contacts n marked by n-grooves
Sleeve contacts B silver-plated gold-plated 100
crimp-type 710 504 710 842 0 0,5 mm² 20 AWG 160 027583
solid, drilled 710 500 710 843 1 0,75 - 1 mm² 18 AWG 171 027545
weight per 100 710 501 710 844 2 1,5 mm² 16 AWG 173 027552
710 502 710 845 3 2,5 mm² 14 AWG 168 027569
710 503 710 846 0 4,0 mm² 12 AWG 163 027576
Pin contacts B silver-plated gold-plated 100
crimp-type 710 514 710 847 0 0,5 mm² 20 AWG 130 027637
solid, drilled 710 510 710 848 1 0,75 - 1 mm² 18 AWG 124 027590
weight per 100 710 511 710 849 2 1,5 mm² 16 AWG 128 027606
710 512 710 850 3 2,5 mm² 14 AWG 129 027613
710 513 710 851 0 4,0 mm² 12 AWG 125 027620

16 ⇒ Matching housings see page 91 - 92


Housings for series
A 10 and D 15 g
EAN-No.
Description Part No. M 4015609...

Housings: single locking system


Wall mount housings, height 52 mm
with single locking system 1. M 20 2. M 20
10
with cable gland 701 410 1 x M 20 210 026562
without cable gland 701 410 OV 197 112852

with cable gland 701 510 2 x M 20 222 026593


without cable gland 701 510 OV 195 112883

Panel housing, height 26 mm 10


with single locking system 704 310 panel 76 026975
cut out
57,5 x 24 mm

8
Wall mount housings, height 52 mm 1. M 20 2. M 20
with single locking system
with spring cover 10
with cable gland 701 610 1 x M 20 232 026623
without cable gland 701 610 OV 219 112913
with cable gland 701 710 2 x M 20 244 026654
without cable gland 701 710 OV 217 112944

Panel housing, height 26 mm


with single locking system 10
with spring cover 704 410 panel 98 027019
cut out
57,5 x 24 mm

Coupler hoods, height 52 mm


with single locking system
top cable entry 10
with cable gland 703 810 1 x M 20 121 026913
without cable gland 703 810 OV 108 113163

M 20

Hoods, height 53 mm
for single locking system M 20
side cable entry 10
with cable gland 702 610 1 x M 20 92 026746
without cable gland 702 610 OV 78 113002

Hoods, height 66 mm
for single locking system
side cable entry 10
with cable gland 708 610 1 x M 20 168 027163
without cable gland 708 610 OV 154 113262
M 20/25

10
with cable gland 708 710 1 x M 25 177 027187
without cable gland 708 710 OV 155 113286

91
BANDO STS SuperTorque SYNCHRONOUS BELT

BANDO STS SuperTorque belts were developed especially for very high requirements as to
power transmission, running characteristics (minimization of the polygon effect, noise reduction)
and drive precision . Based on the excellent ... conditions, STS SuperTorque belts offer the
following product advantages:

• Transmission of higher torques


• Quiet running
• Longer service life
• Increased precision
• No maintenance

Construction :
• NEOPRENE Rubber Backing (Single-toothed)
The tensile members are hermetically enclosed by the durable and flexible backing. It is made
of strong, resistant and very thin neoprene rubber protecting the tensile members from oil,
humidity and wear through friction.
• Tensile Members
The tensile members consist of constantly helically wound glass fibre resulting in high tensile
strength and flexibility.
• NEOPRENE-tooth
The teeth are made from a moderately tough, shear resistant and robust neoprene compound
vulcanised as a unit with the neoprene-backing.
• NYLON-Fabric Canvas
The teeth are covered by a tough and very wear-resistant NYLON-fabric canvas protecting the
teeth against wear. This material has a very low friction coefficient thus additionally supporting
the good running characteristics of the BANDO STS Synchronous Belts.

t H1 H2 W R
Type
(mm) (mm) (mm) (mm) (mm)
S8M 8,00 5,30 3,05 5,20 5,20
REL-B SERIES
RE SERIES

MAINTENANCE-FREE VALVE REGULATED


LEAD-ACID BATTERIES
LAYOUTS

SPECIFICATIONS

)
HR

ion
/20

(V)

ent
g)
(Ah

t (k

ge

onv
ity

igh

lta

tC
pac

Typ
Vo
We

n
Ca

Mo ivae
al
(V)

ng
x.

min
gth

t
l

del
ati
ted

pro
de

igh
th
lts

u
Len
Wid

Eq
Flo
Mo

Ter
Ra

He

Ap
Vo
REL-B15-12 15 12 76 181 167 6.0 13.65 A NPH16-12
REL-B24-12 24 12 125 166 175 10.5 13.65 B -
REL-B38-12 38 12 166 197 175 14.7 13.65 B NP38-12
REL-B65-12 65 12 166 311 175 24.2 13.65 C NP65-12

RE SERIES

3
4.11.2008 B33

DECLARATION OF CONFORMITY

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 21/22
4.11.2008 B33

TYPE APPROVAL CERTIFICATES

ELECTRIC FIRE DOOR CONTROL SYSTEM

Det Norske Veritas: MED-B-3446


MED-B-4154

A-60 SINGLE LEAF SLIDING, SEMI WATERTIGHT DOOR

Det Norske Veritas: MED-B-2820

A-60 SINGLE LEAF SLIDING DOOR

Det Norske Veritas: MED-B-3670

QS-CERTIFICATE OF ASSESSMENT-EC

Det Norske Veritas:


FIRE DOORS MED-E-89
FIRE DOOR CONTROL SYSTEMS MED-E-88

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 22/22
5.11.2008 B33

DOOR LIST

PARMARINE Ltd, BOX 22, 79101 LEPPÄVIRTA, FINLAND, P +358-17-570 211 Fax. +358-17-55 42 725

PAGE 23/23
Product: A-sliding doors, single-leaf Customer ref.: HA-MAT/I-252280/3 06.08.07 order PARMARINE OY LTD
Cusromer: CA Nom_FC_272M121_006.xls 05.09.07 doorlist
Ship: B33 272m 120-a-a33.pdf tech.spec. WORK id: 6149
Cert: EU/DNV: MED-B-3670 XA/V-278741/1 17.04.2008 18.04.08 additional doorleaf (row 13) e-mail TaJo 18.4.08
XA/V-278741/3 22.05.2008 23.05.08 additional frame(row 13) hardcopy TaJo 23.5.08

product identification type and dimensions color, material, additional equipment delivery remarks
ITEM door- width height sill KK handle handle frame handedness

door nbr.

doorpalte2
row

doorplate1
pintap.

pohjap.

karmi

letkul.

lock solenoid

lisäindik.

numero

delivery toim.
room

status
firezone FZ

hoseport

solenoid
kahva-
solenoidi

additional

order tilaus-
deck DK

lukitus-
solenoidi

vko / vuosi
resignation

handle

indication
motor position: back
type VAL VAK height height in width kät. upwards
HH doorleaf P LT moottori:
normaaliasennus

frame
(takareunassa ylhäällä)

12 SAS 06 04 06.0117 F5O16A19 LA60SeO_1600 1990 50 1102 1045 160 oik. N.O. Fe Fe Fe X - X - HA-MAT/I-252280/3 51/07
13 ATRIUM - PREDINER BAR 06 05 06.0067 F5O22A19 LA60SeO_2200 1990 50 1102 1045 155 vas. N.O. Fe Fe Fe X - - - XA/V-278741/3 23/08
14 PASSENGER ALLEYWAY 06 05 06.0132 F5O22A19 LA60SeO_2200 1990 50 1102 1045 140 oik. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 52/07
15 JAZZ BAR 07 04 07.0099 F5O21A19 LA60SeO_2100 1990 80 1132 1045 190 vas. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 45/07
16 SPORTING BAR 07 04 07.0100 F5O21A19 LA60SeO_2100 1990 80 1132 1045 190 oik. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 45/07
17 PHOTO GALLERY 07 07 07.0112 F5O24A19 LA60SeO_2400 1990 60 1112 1045 180 oik. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 51/07
18 TEX MEX 07 07 07.0113 F5O24A19 LA60SeO_2400 1990 60 1112 1045 180 vas. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 51/07
19 INSIDE POOL 14 03 14.0225 F5O18A19 LA60SeO_1800 1990 40 1092 1045 220 oik. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 03/08
20 INSIDE POOL 14 03 14.0226 F5O18A19 LA60SeO_1800 1990 40 1092 1045 220 vas. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 03/08
21 CAFETERIA 14 07 14.0163 F5O20A19 LA60SeO_2000 1990 50 1102 1045 170 vas. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 03/08
22 CAFETERIA 14 07 14.0171 F5O20A19 LA60SeO_2000 1990 50 1102 1045 170 oik. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 03/08
23 CAFETERIA 14 08 14.0205 F5O20A19 LA60SeO_2000 1990 50 1102 1045 200 oik. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 08/08
24 CAFETERIA 14 08 14.0206 F5O20A19 LA60SeO_2000 1990 50 1102 1045 200 vas. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 08/08
25 DISCO 16 05 16.0031 F5O20A19 LA60SeO_2000 1990 50 1102 1045 90 oik. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 03/08
26 DISCO 16 05 16.0049 F5O20A19 LA60SeO_2000 1990 50 1102 1045 90 vas. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 03/08
27 TEEN'S ARCADE 16 06 16.0037 F5O20A19 LA60SeO_2000 1990 25 1077 1045 180 vas. N.O. Fe Fe Fe X - - - HA-MAT/I-252280/3 03/08
Product: A-LIUKUOVET SWT PARMARINE OY LTD
Customer: CHANTIERS DE L'ATLANTIQUE
Ship: B33 WORK id: 6149_11696
Cert: EU/DNV MED-B-2820

product identification type and dimensions color, material, additional equipment delivery
door doortype width height sill KK handle handle frame handed order

karmi

kahva-
designation

doorplate1
pintap.

doorplate2
pohjap.

handle
solenoid

lock solenoid

page/pos.sivu/
row

room

deck DK

firezone FZ

delivery
emergency
opening

production
hoseport

solenoidi

pos.

series
lukko-solenoidi
nbr. VAL VAK height in height width ness
doorleaf HH LT
P

frame
1 4 07 04.0179 LA60We_ab 1500 1990 55 1045 1079 90 vas X Fe Fe Fe HA-MAT/I-252280/1 4807 1
2 4 07 04.0180 LA60We_ab 1500 1990 55 1045 1079 90 oik. X Fe Fe Fe HA-MAT/I-252280/1 4807 1
3 4 07 04.0181 LA60We_ab 1200 1990 55 1045 1079 140 oik. X Fe Fe Fe HA-MAT/I-252280/1 4707 1
4 4 07 04.0182 LA60We_ab 1200 1990 55 1045 1079 140 vas. X Fe Fe Fe HA-MAT/I-252280/1 4707 1
6 4 04 04.0184 LA60We_ab 900 1990 55 1045 1079 170 vas. X Fe Fe Fe HA-MAT/I-252280/1 4107 1
7 4 05 04.0185 LA60We_ab 1200 1990 55 1045 1079 90 oik. X Fe Fe Fe HA-MAT/I-252280/1 3907 1
8 4 01 04.0186 LA60We_ab 1500 1990 55 1045 1079 170 vas. X Fe Fe Fe HA-MAT/I-252280/1 5107 1
9 4 01 04.0187 LA60We_ab 900 1990 55 1045 1079 170 vas. X Fe Fe Fe HA-MAT/I-252280/1 5107 1
10 4 05 04.0188 LA60We_ab 900 1990 55 1045 1079 170 vas. X Fe Fe Fe HA-MAT/I-252280/1 3907 1
11 5 01 05.0117 LA60We_ab 2200 1990 55 1045 1079 370 oik. X Fe Fe Fe HA-MAT/I-252280/1 0608 1
12 4 03 04.0204 LA60We_ab 1600 1990 55 1045 1079 90 oik. X Fe Fe Fe HA-MAT/I-252280/1 2