Mann Process Filters
Mann Process Filters
Contents
• HydroFluid Page 7
• AutoFluid Page 11
2
MANN+HUMMEL – Partner to Industry
MANN+HUMMEL’s extensive Automotive Technology Industrial Filters Business The product range includes:
product range comprises Unit – Solutions for nume-
products and services for • Air cleaner systems rous filtration applications • Air cleaners and cabin
various industries. The com- • Intake Manifold Systems filters
pany organization consists • Liquid filter systems The Industrial Filters • Liquid filters
of two company divisions • Filters business unit in Speyer • Process filters
for automotive and industrial has customers in almost • EDM filters
applications divided into seven Industrial Technology all technical fields: • Air/oil separators
business units. This speziali-
sation enables us to react • Industrial Filters • Mechanical engineering
more flexibly to the individual • ProTec and production technology
needs of our customers. • Hydromation • Industrial engines, con-
struction and agricultural
machines
• Compressed-air and
vacuum technology
• Representatives and
subsidiaries
3
Efficient and economic solutions
The filtration of products Applications which involve So choose MANN+HUMMEL A wide range of
and liquids in a production the filtration of process as your filter partner. We MANN+HUMMEL services
process often demands the liquids are never the same. offer efficient and economic also ensures that you will
highest requirements from Basic parameters such as solutions. Our expertise be professionally advised
a filter system. Customers dirt volumes, type of dirt, combined with an extensive during the consultation
need low-cost solutions nominal flow rate or gap product range incorporating process and after the
which offer maximum pro- widths will always vary. Ideal a variety of cleaning systems purchase of your
cess reliability. function and economy can enables customised solutions MANN+HUMMEL filter
therefore only be achieved available for each individual system.
with a filter solution which application.
is specially adapted to the
application. In the long run
standard products „off the
shelf“ are inefficient and
expensive.
4
Overview of all process filters
5
6
HydroFluid
Dynamic filter system
7
HydroFluid –
the fine one for a lot of dirt
The HydroFluid dynamic filter continuous production flow All advantages at a glance:
system from MANN+HUMMEL as is required for industrial
is an innovative product which, application areas. • high dirt volumes with
regarding efficiency and eco- The HydroFluid functions simultaneous small gap
nomy, sets new standards in without interrupting production widths from 10 µm
the field of continuous filtration as is often necessary with • continuous filter cleaning
of liquids containing solids. other systems due to a filter without loss of performance
It has been very successful change, backflushing or • continuous production
for applications with high dirt switchover to a parallel filter process
volumes where small gap system. As a result sensitive • process reliability through
widths are also required. A production processes enjoy defined gap widths
new kind of hydrodynamic stable production conditions • lasting filtration of fibrous
cleaning principle enables without process fluctuations. materials and suspended
matter
• change of filter elements
unnecessary
• low maintenance costs
• very economic
8
Working principle of the HydroFluid
The dirtied liquid flows tan- rotate the liquid. Centrifugal ciency. Both effects also pre- carried out at defined time
gentially into the ring channel forces transport dirt particles vent filter cake from forming intervals.
located separately from the from the insert in the direc- on the surface of the insert
housing of the HydroFluid. tion of the housing wall where so that this remains perma- The HydroFluid with its
The ring channel design they are continuously deflec- nently free. The design of innovative working principle
dampens the flow and achie- ted downwards. the dirt collection chamber is the first automatic filter
ves an ideal preseparation. enables an ideal build-up of which allows the continuous
The dynamic scrapers gene- dirt and the tangential dis- fine filtration of heavily dirtied
Dynamic scrapers move rate a partial vacuum (Fig. 2) charge of sludge from the liquids.
around the insert without and unstable flow conditions filter. The sludge discharge
making contact. The scrapers on the surface of the insert. is either regulated by means
additionally displace and This improves filtration effi- of differential pressure or
Insert
Unfiltered
media side
Dynamic scrapers Support profile
Sludge
discharge
Die hydrodynamic cleaning and local pressure differences dirt particles onto the surface flow (with a partial vacuum)
effects can be explained by in the filter housing. The of the insert so that they are through the insert. This pro-
looking at the pressure distri- result is that the insert is scraped off without direct cess repeats itself many times
bution in the filter housing. cleaned continuously. contact. At the same time per second at each position of
The rotation of the dynamic there is a pressure reduction the insert.
scrapers at a speed of approx. The scraper pushes a shoul- (blue) at the rear end of the
12 m/s generates turbulence der wave (red) in front raising scraper generating a back
9
a
b
d
a b c d e f
Sizes 100 96 200 28 001 Stainless steel (1.4301) 320 1140 700 R2 R2 ø 508
Sizes 200 96 200 48 001 Stainless steel (1.4301) 410 1200 900 R 21/2 R 21/2 ø 600
* Other materials on request.
10
AutoFluid
Automatic backflushing filter
11
AutoFluid –
the fine one for low and high viscosity liquids
• high potential for reducing • quick cleaning cycles with • easy to service
operating costs minimal backflushing
volumes and pressure loss • variable and easy integra-
• fully-automatic operation tion of a filter in an existing
• compact system thanks to production line
• long service life the easy-to-clean charac-
teristics of the inserts • easy operation with the
• process reliability through supplied control system
a defined sieve geometry • high stability of inserts with
varying differential pressu- • innovative design
• gap widths from 10 µm res
12
Working principle of the AutoFluid
13
Filtration Filtered media side
Unfiltered media side
Backflushing
Filtered media side The dirt particles filtered out and the sludge discharge
Unfiltered media side lead to an increase in the valve is opened. As a result
differential pressure. When the insert is cleaned. After the
Valve inlet
closed the pre-set differential pres- cleaning of the first insert has
sure is reached, all four taken place, the other three
inserts are backflushed one inserts are backflushed one
after the other without stop- after the other. When the
ping the operation of the backflushing cycle has ended
whole system. During this the differential pressure in the
cleaning process the inlet in filter has returned to its initial
the respective insert is closed value.
14
550 440
G3
G3
760
629
ø 70
AutoFluid
insert
15
16
Profluid and Gap-type tube filters
Automatic filters
17
Profluid and Gap-type tube filters –
the efficient answer for multi-purpose applications
Automatic filters such as Gap-type tube filters can it very efficient for filtration
Profluid or Gap-type tube be cleaned during operation tasks where varying types
filters are used to efficiently by means of mechanical and sizes of particle must be
increase the service life of scraping. The Profluid is an filtered out of a liquid. This
process liquids. They are automatic self-cleaning filter working principle has proven
suitable for the filtration of system with a design based to be extremely efficient for
low and high viscosity media. on gap-type technology. The gap widths under 100 µm.
Accordingly, they may be combination of cleaning by
used in almost all industrial backflushing together with
fields. mechanical scraping makes
18
The advantages at a
glance:
Profluid
• high performance regarding
filter fineness and nominal
flow rates
• gap widths from 30 µm
• effective dual cleaning
mechanism
• automatic cleaning without Gap-type tube filters
interrupting production • easy to service
• robust and reliable • gap widths from 50 µm
• individual setting of back- • automatic cleaning without
flushing cycles interrupting production
• reliable with all kinds of • the classic filter - proven
dirt particles time and time again
• economic • economic
19
The working principle
Rotating
gap-type tube (3)
Profluid
Backflusing chamber (7)
+ Scraper (5)
Filtered Unfiltered
media side media side
Housing (2)
Profluid
20
The working principle
Unfiltered
Filtered media side media side
Gap width
Backflushing
chamber
(only Profluid)
Usual direction of flow
Backflushing direction
of flow
The medium to be cleaned Driven by a geared motor (4), Particles from a certain size towards the outside. The
flows into the housing (2) the gap-type tube rotates up cannot be removed by the backflushing procedure is
via the filter inlet (1) and along a stationary scraper scraper. On conventional submitted to specific para-
passes through the gap-type plate (5) that removes the gap-type tube filters, they meters, such as operation
tube (3) from the outside to filter cake. It then sinks to the deposit in the gaps and – hours, time pulse and in-
the inside. All impurities in bottom of the housing and is under certain operation crease of the differential
the medium which are larger discharged when necessary conditions – quickly clog pressure.
than the gap width are re- via the sludge outlet (6). To the filter.
tained on the surface of the simplify the disposal of the Operating pressure and set
tube. The coarse dirt particles solid particles filtered out, a Near size particles can be backflush volume influence
either sink to the lower part drying valve can be installed. eliminated from the gap-type decisively the efficiency of
of the housing or form a filter tube through the use of a backflushing.
cake on the exterior surface backflushing chamber (7).
of the tube. The whole length of the tube Profluid’s combined action
is flushed: When the back- of dirt scraping and back-
flushing line is opened, the flushing, a patented
medium flows into the un- procedure, ensure quality
pressurized backflushing cleaning without interrup-
chamber in opposite direction ting the production.
to normal, and is drained
21
Specifications and order numbers DN 50
813
ø 57 405.5
420 ø 57 405.5
232
232
M 22x1.5
210
Sludge outlet G1
ø 108
22
Specifications and order numbers DN 65
1080
ø 85 644
640 ø 85 644
358
358
G 3 /4
232.5
Sludge outlet G1
ø 170
Gap widths 30 µm (nur Profluid), 50 µm, 75 µm, 100 µm, 150 µm, 200 µm, 500 µm
(other gap widths on request)
Nominal flow rate 30 m3/h with 0.1 bar initial differential pressure, gap width 50 µm
(e.g.: water, 25 °C) 50 m3/h with 0.5 bar initial differential pressure, gap width 50 µm
Connections DN 65 PN 16 (unfiltered and filtered media side), G 11/2 (sludge outlet)
G 3/4 (backflushing, only Profluid)
Backflushing Integrated (backflushing, only Profluid)
Sludge outlet Integrated
Permissible operating pressure 12 bar
Differential pressure supervision Available
Pressure on the unfiltered media side P1 = 1.5 – 12 bar
Permissible operating temperature 100 °C (higher temperatures on request)
Materials Aluminium, aluminium chemically nickeled, other materials on request
Mains connection 230 V AC, 50/60 Hz
Control Available
Sludge outlet valves and backflushing Available
Backflushing medium Own medium (only Profluid)
Cleaning Time or differential pressure dependent as option
Version for explosive atmospheres Optional
Filter configuration For your filter system enquiry please use the filter
configuration questionnaire on page 50.
23
Specifications and order numbers DN 80
1310
ø 97 745
770 ø 97 745
400
400
Sludge outlet DN 50
ø≠220
Gap widths 30 µm (nur Profluid), 50 µm, 75 µm, 100 µm, 150 µm, 500 µm
(other gap widths on request)
Nominal flow rate 50 m3/h with 0.3 bar initial differential pressure, gap width 50 µm
(e.g.: water, 25 °C) 80 m3/h with 0.6 bar initial differential pressure, gap width 50 µm
Connections DN 80 PN 16 (unfiltered and filtered media side), DN 50 PN 16 (sludge outlet)
G1/DN 25 PN 16 (backflushing, only Profluid)
Backflushing Integrated (backflushing, only Profluid)
Sludge outlet Integrated
Permissible operating pressure 12 bar
Differential pressure supervision Available
Pressure on the unfiltered media side P1 = 1.5 – 12 bar
Permissible operating temperature 100 °C (higher temperatures on request)
Materials Aluminium, aluminium chemically nickeled, other materials on request
Mains connection 230 V AC, 50/60 Hz
Control Available
Sludge outlet valves and backflushing Available
Backflushing medium Own medium (only Profluid)
Cleaning Time or differential pressure dependent as option
Version for explosive atmospheres Optional
Filter configuration For your filter system enquiry please use the filter
configuration questionnaire on page 50.
24
Specifications and order numbers DN 100
1780
ø 190 1050
1200 ø 190 1050
625 625
Sludge outlet DN 80
ø 340
Gap widths 30 µm (nur Profluid), 50 µm, 75 µm, 100 µm, 150 µm, 200 µm, 500 µm
(other gap widths on request)
Nominal flow rate 80 m3/h with 0.2 bar initial differential pressure, gap width 50 µm
(e.g.: water, 25 °C) 100 m3/h with 0.4 bar initial differential pressure, gap width 50 µm
Connections DN 100 PN 16 (unfiltered and filtered media side), DN 80 PN 16 (sludge outlet)
DN 50 PN 16 (backflushing, only Profluid)
Backflushing Integrated (backflushing, only Profluid)
Sludge outlet Integrated
Permissible operating pressure 12 bar
Differential pressure supervision Available
Pressure on the unfiltered media side P1 = 1.5 – 12 bar
Permissible operating temperature 100 °C
Materials Aluminium, aluminium chemically nickeled, other materials on request
Mains connection 230 V AC, 50/60 Hz
Control Available
Sludge outlet valves and backflushing Available
Backflushing medium Own medium (only Profluid)
Cleaning Time or differential pressure dependent as option
Version for explosive atmospheres Optional
Filter configuration For your filter system enquiry please use the filter
configuration questionnaire on page 50.
25
26
Wire and Plate gap-type filters
27
Wire and Plate gap-type filters
Stationary
The Plate gap-type filter discs, the dirt particles are gap cleaner
insert consists of steel discs deposited on the surface and
which are piled up on a in the gaps. By turning the
central pin. insert with the handle, the
The gap width between the dirt gathers on the row of
discs is determined by gap cleaners and falls into
spacers between the discs. the sludge collection cham-
A stationary gap cleaner ber where it is discharged
runs through every gap. As by opening a ball valve.
the fluid flows between the
Gap width
28
ca. 500 M 16
32 deep ø 56 ca. 420
Screw
holes 250
ø 125
Sludge outlet G1
ø 108
Gap widths Plate gap-type filters 100 µm, 200 µm, 400 µm, 800 µm
(other gap widths on request)
Nominal flow rate 12 m3/h with 0.3 bar initial differential pressure, gap width 100 µm
(e.g.: water, 25 °C)
Gap widths Wire gap-type filters 30 µm, 50 µm, 100 µm, 150 µm, 200 µm, 500 µm
(other gap widths on request)
Nominal flow rate 10 m3/h with 0.15 bar initial differential pressure, gap width 50 µm
(e.g.: water, 25 °C) 15 m3/h with 0.30 bar initial differential pressure, gap width 50 µm
Connections Metric threads, pipe threads and flange
Sludge outlet Integrated
Permissible operating pressure 40 bar (4 MPa)
Differential pressure supervision Integrated, adjustable
Pressure on the unfiltered media side P1 = 1.5 - 40 bar
Permissible operating temperature 100 °C
Materials Housing: AL, GG 1.4581
Insert: AL, GG 1.4301
Mains connection for drive 230/110 V AC, 50/60 Hz
Control and supervision Optional
Control for dirt outlet Time or differential pressure dependent as option
Version for explosive atmospheres Optional
Filter configuration For your filter system enquiry please use the filter
configuration questionnaire on page 50.
29
30
High-Pressure Filters
Hydraulic filtration
31
High-Pressure Filters
Design Application Versions available:
P
without bypass valve
with service switch
32
High-Pressure Filters
Tank
Suction filter
Low-pressure filter
Technical data
Filter element Performance data as per ISO 4572 at a differential pressure of 5 bar (500 KPa)
(differential pressure stability)
HD ... / 1 ß6 ≥ 75
HD ... / 2 ß10 ≥ 75 (∆p 15 bar/1.5 MPa)
HD ... / 3 ß10 ≥ 75 (∆p 60 bar/6.0 MPa)
HD ... ß25 ≥ 75
33
High-Pressure Filters
Nominal pressure 200 bar (20 MPa)
Characteristics
2.0
Differential pressure ∆ p (bar)
/1
46
1.0 HD
0.5
0.3
X
0.2 /3
46
HD
/2,
46 46
0.1 HD HD
0.05
h2
0.03 Service switch
swivels by 360°
0.02
1 2 3 4 5 10 20 30 50 100 21.5
d
Volume flow (l/min)
182 ø 63
SW 19
ø 52
removal clearance 125
52
62
34
High-Pressure Filters
Nominal pressure 400 bar (40 MPa)
2.0
Differential pressure ∆ p (bar)
Characteristics
1.0
0.1
0.05
0.03
5 10 20 30 50 100 200 500
25.5
G 3/4 G 3/4
158.5 View X
ø 100 M 10, 20 deep
Service switch
swivels by 360°
38
15
SW 36 75
h2
6 kt removal
ø 78 clearance 12 18
35
High-Pressure Filters
Nominal pressure 400 bar (40 MPa)
2.0
0.1
X 0.05
h2
25.5
G1 G1
211.5
ø 100 Dimensions and part
numbers
View X
M 10, 20 deep
Service switch
swivels by 360°
38
15
h2
12 18
36
High-Pressure Filters
Nominal pressure 400 bar (40 MPa)
2.0
Differential pressure ∆ p (bar)
Characteristics
1.0
0.5
Flow resistance as per
2
3/
61 ISO 3968 at 32 mm2/s.
0.3 HD
1,
3/ 3
61 61
0.2 HD HD
0.1
0.05
0.03
5 10 20 30 50 100 200 500
258.5
ø 100
View X
M 10, 20 deep
Service switch
swivels by 360°
38
15
SW 36 125 h2
removal
4 kt
clearance 12 18
ø 79
37
High-Pressure Filters with star-pleated strainer inserts
For the filtration of polyurethane components
These high pressure filters To meet the requirements of Please send us the fax on
are used primarily for the reaction injection moulding page 50. We would like to
filtration of polyurethane com- machines MANN+HUMMEL help you determining the
ponents. The filter housings has developed special inserts. optimal filter for your special
are the same as on page 34 application.
to 37.
Technical Data
Filter fineness: 25 to 200 µm
Nominal flow rate: 25 to 175 l/min
Operating pressure: maximum 400 bar (40 MPa)
Operating temperature: -25 °C to +120 °C
Material: Filter head: cast iron with spheroidal graphite
Filter can: steel (also chemically nickeled)
Insert:
Collapse-/burst pressure as per ISO 2941: max. 45 bar (4.5 MPa)
38
High-Pressure Filters with star-pleated strainer inserts
Nominal pressure 400 bar (40 MPa)
G 3/4 G 3/4
View X
M 10, 20 deep 168
ø 100
38
15
SW 36 75
6 kt removal clearance
12 18 ø 78
Type 300
Housing
39
High-Pressure Filters with star-pleated strainer inserts
Nominal pressure 400 bar (40 MPa)
G 3/4 G 3/4
268
View X ø 100
M 10, 20 deep
38
15
SW 36 175
removal clearance
4 kt
12 18 ø 75
Type 302
Housing
40
High-pressure filters with star-pleated strainer inserts
Nominal pressure 400 bar (40 MPa)
View X 152
49 55
100 M 12 144
25 min
deep
20 439
ø 110
Example:
Type 506
Housing
41
42
Technical service
43
Excellent service
44
Excellent service
The ideal fine tuning of the A service contract with A regular filter service offers • use of original spare parts
filter to your requirements is MANN+HUMMEL offers you you the following advanta- for MANN+HUMMEL pro-
ensured by the installation the maximum reliability of ges: ducts and other brands
and startup carried out by operation. Our service offer • high process reliability • ideal operating conditions
our experts. During filter start- not only covers our own fil- • filter guarantee for the and good economy
up we train your operating ters, but also includes other duration of the contract, • transparent filter operating
personnel in your company brands. The result is you can i.e. we ensure the filter costs and return on invest-
on how to handle the filter. have all your production line functions during the con- ment
filters serviced by one spe- tract period without extra • an easy solution for you
cialist. Together with you we costs for you. since you can rely on
draw up the service intervals. MANN+HUMMEL as our
customer.
45
46
Useful information
47
Viscosity/temperature chart
mm2/s
2 000 000
1 000 000
500 000
300 000
200 000
100 000
70 000
50 000
30 000
20 000
10 000
7 000
5 000
4 000
3 000
2 000
1 500
1 000
800
700
600
500
400
300
AT
F
200 oil
HD
Viskosity
150 40
en
gi
100 ne
90 oi
80
l
70
60
50
HD
40 HD
30
10 en
30
W gi
en ne
gin oi
25
e l
oil
20 IS
O
17 VG
15 10
14 0
13 (H
12 -L
P
11 10
10 0)
9 IS
O
8 VG
IS 32
7 O
VG (H
-L
6 22 P
(H 32
-L )
P
5 22
)
4.5
4.0
3.5
3.0
2.8
48
Viscosity/temperature chart
mm2/s
30 000
20 000
10 000
7 000
5 000
4 000
3 000
2 000
Ex Oi
1 500 tra l fo
he rs
1 000 up
av er
800 y he
700 he at
600 at ed
500 in ste
g am
400 oi
l( cy
300 Bu lin
nk de
er rs
200 C US
)
fu
150 el
oi
l,
100 gr
ad
90 e
80 Mu 6
70 ltig
60 ra
de
50 oil
Viskosity
40
C
ut Mu
30 tin M
g ltig ult
25 oi ra igr
l de ad
oil e
20 oil
20
17 W
-5
15 0
14
13 15
12 W
11 -4
10 0
10
W
9 -3
8
0
G
as
7
oi
l
R
an
6 ge
Ke of
ro fu
se
US
5 ne el
oi
he
4.5 ls
at
in
g
4.0
oi
l,
gr
ad
3.5
e
2
3.0
2.8
Di
2.5 es
el EL
2.3 fu
el he
at
in
g
2.0 oi
l
1.7
1.5
49
Configuring the size of filters for liquids
Fax to: c o p y,
fill ou
t and
FILTERWERK Fax N fax
o. +49
MANN+HUMMEL GMBH (62 32
) 53 –
Geschäftsbereich Industriefilter, Dept. IF-V1 81 50
67323 Speyer, Germany
Please send us information on a filter for liquids for the following application:
• Use/process:
• Type of contamination:
• Type of impurities:
• Other:
Company
Name
Department
Street
Postal code/City
Country
Telephone
Mobile phone
Fax
50
Conversion factors
51
Further information on our products is obtainable
under the following brochure titles:
" Single stage air cleaners " Spin-on filters " Automatic filters " Standard wrap elements
" Two stage air cleaners " Fuel filters " Gap-type filters " Depth Separator element
" Vacuum filters " Filter elements for liquid " High pressure filters " Air-oil separator boxes
" Filters for two-way venti- filters " Air-oil separator filters
lation " In-line filters
" Oil-wetted air cleaners " Suction filters
" Oil bath air cleaners " Two-way ventilation filters
" Accessories, e.g. supports,
sludge outlet valves, service
switches, etc
52
International locations
„Made by MANN+HUMMEL“, worldwide.
• Locations
• Licensees
• FILTERWERK MANN+HUMMEL GMBH, Ludwigsburg (Germany) • FILTROS MANN S.A. de C.V., Tlalnepantla (Mexiko)
• FILTERWERK MANN+HUMMEL GMBH, Marklkofen (Germany) • FILTERWERK MANN+HUMMEL GMBH, Warsaw (Poland)
• FILTERWERK MANN+HUMMEL GMBH, Speyer (Germany) • MANN+HUMMEL FILTER TECHNOLOGY (S.E.A.) PTE LTD,
• FILTERWERK MANN+HUMMEL GMBH, Sonneberg (Germany) (Singapore)
• MANN+HUMMEL ProTec GmbH, Königswinter (Germany) • FILTROS MANN S.A., Saragossa (Spain)
• MANN+HUMMEL ProTec GmbH, Ludwigsburg (Germany) • G.U.D. MANN+HUMMEL FILTER SYSTEMS (PTY) LTD,
• MANN+HUMMEL ProTec GmbH, Weiterstadt (Germany) Atlantis (South Africa)
• MANN+HUMMEL HYDROMATION GMBH, Ludwigsburg (Germany) • MANN+HUMMEL (CZ) s.r.o., Nová Ves
• MHB FILTRATION GMBH+CO. KG, Erkrath (Germany) (Czech Republic)
• FILTROS MANN S.A., Buenos Aires (Argentina) • MANN+HUMMEL FILTER TECHNOLOGY, INC.,
• MANN AND HUMMEL AUSTRALIA PTY LIMITED, Greensboro, NC (USA)
Sydney (Australia) • UNIVERSAL DYNAMICS, INC., Woodbridge, VA (USA)
• MANN+HUMMEL HYDROMATION N.V., Tongeren (Belgium) • MANN+HUMMEL AUTOMOTIVE, INC., Bloomfield Hills,
• FILTROS MANN LTDA., Indaiatuba (Brazil) MI (USA)
• FILTERWERK MANN+HUMMEL GMBH, Shanghai (China) • MANN+HUMMEL ADVANCED FILTRATION CONCEPTS, INC.,
• HYDROMATION FRANCE S.A.R.L., Paris (France) Louisville, KY (USA)
• MANN+HUMMEL FRANCE S.A.R.L., Argenteuil (France) • MANN+HUMMEL AUTOMOTIVE, INC., Portage, MI (USA)
• MANN+HUMMEL (UK) LTD.,
Wolverhampton (United Kingdom)
• MANN+HUMMEL (UK) LTD., Ilminster (United Kingdom) • J. Riveros S.A.I.C., Santiago (Chile)
• MANN+HUMMEL JAPAN LTD., Yokohama (Japan) • G.U.D. Filters Pty. Ltd., Durban (South Africa)
53
Notes
54
The Group
The MANN+HUMMEL Automotive Technology Division
Group has its head offices
in Ludwigsburg in the
German state of Baden- Air Filter Systems Liquid Filter Systems Filters Business Unit (AM)
Württemberg close to the Business Unit Business Unit • Filter elements for air and
state capital of Stuttgart. • Air cleaners and air filter • Plastic and aluminum liquid liquids, and cabin filters
systems for automobiles filter systems for auto- (MANN-FILTER)
MANN+HUMMEL is repre- and commercial vehicles mobiles and commercial • Cabin filters for particle
sented in 30 locations all • Components, e.g. mufflers, vehicles filtration and gas adsorption,
over the world and its control cabinets, heating • Components, e.g. integrated and combined filters for
workforce consists of pipes, control valves, oil-water heat exchangers automobiles and commer-
approximately 8,000 design covers • Oil sumps, valves cial vehicles
employees. • Crankcase ventilation • Air-drying boxes
systems • Cooling-water filters
The automotive industry, • Spin-on oil filters and fuel
mechanical engineering filters
and the plastics proces- Intake Manifold Systems • Elements for oil mist
sing industry are among Business Unit separators
the international customers • Engine intake manifolds,
of MANN+HUMMEL. intake manifold modules
To meet the different and systems made of
requirements of all these plastic and metal for auto
customers efficiently, mobiles and commercial
MANN+HUMMEL is divided vehicles
into seven business units. • Components for auto-
mobiles and commercial
vehicles, e.g. fuel rails, oil
mist separators, cylinder
head covers