Huawei Base station
Power Consumption Monitoring
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Power Consumption Monitoring Solution
BBU
Power Efficiency
Monitoring
RRU
OM
Statistics & Analysis
Description:
The BTS periodically measures and reports its power consumption to the M2000, which can deliver some statistics
report for power consumption analysis. Available in GSM, UMTS, LTE.
Benefit:
Easy monitoring of the BTS power consumption.
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 2
Power Consumption Monitoring Principles
Without Huawei PMU Energy consumption With Huawei PMU
by module adding
AC PSU DC RRU (1)
DC RRU (1)
…
∑ PSU
PSU
…
RRU (n) BSC,GW
RRU (n) BTS/NodeB BSC,GW
PMU
/eNodeB level BBU
BBU Sensor
PMU: Power Monitoring Unit
Sensor
PMU calculates the power consumption based on the
BBU calculates the module’s power consumption based
inquired PSU’s output voltage and current, then reports
on the module’s report and reports to M2000.
to BBU. BBU reports the power consumption to M2000.
DC IN
Sensor DC OUT There is a sensor for power consumption metering in
or
PSU and power supply modules of RRU and BBU.
AC IN Power Supply Module
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 3
Power Consumption Monitoring Features (RAN, OSS)
GSM UMTS LTE remark
BTS feature/function: BTS basic, basic, optional,
energy conmsumption No feature ID/name WRFD-020406 LOFD-001041 Power
accuracy:10%
report basic support of energy Intelligent Power Consumption Monitoring
consumption report (GBSS13) Measurement (RAN13) (eRAN2.0)
M2000 feature: optional optional optional funtion:(hourly counter report)
power consumption WOFD-200500:Base Station WOFD-200600:Base WOFD-200200:Base 1):BS Traffic and Energy Consumption
monitoring Power Saving Management - Station Power Saving Station Power-Saving 2):BS Traffic and Energy Consumption
GBSS Management -WRAN Management -LTE Comparison
PRS feature: optional: optional: optional:
funtion:(hourly/daily/weekly/monthly
Predefined Report—BS WOFD-090800 GSM BSS WOFD-091000 UMTS WOFD-091600 eRAN
report)
Energy Consumption Predefined Report RAN Predefined Report Predefined Report
1):BS Traffic and Energy Consumption
Report location:Root-GSM BSS location: location:
2):BS energy efficiency report
Performance Root-NodeB Root-eRAN Performance
Report-BTS Energy Performance Report-BTS Energy
sub-feature name: BS Energy
Consumption Report Report-BTS Energy Consumption Report
Consumption Report.
Consumption Report
(PRS V100R007C01)
Hardware support 3900 series base stations, 3900 series base 3900 series base stations
except BTS3900B, BTS3900E stations including
BTS3902E. Not
supported by BTS3803E.
licenses required M2000 M2000 eRAN, M2000
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 4
Power Monitoring Counters and Detection point
PSU BBU BSC,GW
AC
PSU ∑ RFU /RRU(1)
PSU
PMU
RFU/RRU (n) M2000
Other equipments FAN
(transmission,Battery,A/C)
BTS AC side BTS DC side
Counter name/ID——GSM Counter name/ID——GSM
SITE.EnerConsump.MEASURING / 1282449257 SITE.EnerConsump.ADDING / 1282449256 SRAN6.0 counter (GBTS)
VS.EnergyCons.BTS.Measuring / 1593835639 VS.EnergyCons.BTS.Adding / 1593835640 SRAN8.0 counter (eGBTS)
Counter name/ID-UMTS Counter name/ID-UMTS
VS.BTS.EnergyCons.Measuring / 50333221 VS.BTS.EnergyCons.Adding/ 50333220 SRAN6.0 counter
Counter name/ID-LTE Counter name/ID-LTE
VS.BTS.EnergyCons.Measuring / 1526728210 VS.BTS.EnergyCons.Adding/1526728153 SRAN6.0 counter
LTE only module Counter name/ID LTE only module Counter name/ID eRAN2.0 counter (LTE
VS.EnergyCons.BBU*/1526727551 only) – will be deleted
VS.EnergyCons.PMU / 1526727549
VS.EnergyCons.RRU/1526727065 after SRAN8.0
*Note: actual BBU power consumption monitoring requires the UPEUc board
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 5
Counters details (GSM)
GBTS/eGBTS Power Consumption
Counter ID / Name Description Measurement Point
For GBTS: This counter measures the power The system samples the power consumption of boards and RF
1282449256 / consumption of GSM within a measurement modules working in GSM mode every 5 minutes. At the end of
SITE.EnerConsump.ADDING period, which equals the sum of the power a measurement period, the sum of these estimated sampling
consumption of boards and RF modules results is used as the value of this counter.
For eGBTS (from SRAN8.0): working in GSM mode. Unit: kWh
1593835639 /
VS.EnergyCons.BTS.Adding.GSM
For GBTS: The counter measures the power The power consumption monitored by all the PMUs is sampled
1282449257/ consumption of the BTS within a every 5 minutes. At the end of a measurement period, the sum
SITE.EnerConsump.MEASURING measurement period, which is calculated by of these sampling results is used as the value of the counter.
the power system based on the detected Unit: kWh
For eGBTS (from SRAN8.0): current and voltage.
1593835640 /
VS.EnergyCons.BTS.Measuring.GSM
Note: eGBTS is a GSM BTS configured with UMPT control board (available from SRAN8.0).
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 6
Counters details (UMTS)
NodeB Power Consumption
Counter ID / Name Description Measurement Point
50333220 / This counter measures the power The system samples the power consumption of boards and RF
VS.BTS.EnergyCons.Adding (*) consumption of the UMTS within a modules working in UMTS mode every 5 minutes. At the end of
measurement period, which equals the sum a measurement period, the sum of these estimated sampling
From SRAN8.0 version: of the power consumption of boards and RF results is used as the value of this counter.
1593835628 / modules working in UMTS mode. Unit: kWh
VS.EnergyCons.BTS.Adding.UMTS
50333221 / The counter measures the power The power consumption monitored by all the PMUs is sampled
VS.BTS.EnergyCons.Measuring (*) consumption of the NodeB within a every 5 minutes. At the end of a measurement period, the sum
measurement period, which is calculated by of these sampling results is used as the value of the counter.
From SRAN8.0 version: the power system based on the detected Unit: kWh
1593835629 / current and voltage.
VS.EnergyCons.BTS.Measuring.UMTS
Note:
(*) Those counters will be deleted in later versions, it is therefore recommended to use new counters introduced in SRAN8.0 as soon as possible.
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 7
Counters details (LTE)
eNodeB Power Consumption (1)
Counter ID / Counter Name Description Measurement Point
1526728153 / This counter measures the power The system samples the power consumption of boards and RF
VS.EnergyCons.BTS.Adding (*) consumption of LTE within a modules working in LTE mode every 5 minutes. At the end of a
measurement period, which equals the measurement period, the sum of these estimated sampling results
From SRAN8.0 version: sum of the power consumption of is used as the value of this counter.
1593835637 / boards and RF modules working in LTE Unit: kWh
VS.EnergyCons.BTS.Adding.LTE mode.
1526728210 / The counter measures the total power The power consumption monitored by all the PMUs is sampled
VS.EnergyCons.BTS.Measuring (*) consumption monitored by all the every 5 minutes. At the end of a measurement period, the sum of
PMUs within a measurement period. these sampling results is used as the value of the counter. Unit:
From SRAN8.0 version: kWh
1593835638 /
VS.EnergyCons.BTS.Measuring.LTE
Note:
(*) Those counters will be deleted in later versions, it is therefore recommended to use new counters introduced in SRAN8.0 as soon as possible.
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 8
Counters details (LTE)
eNodeB Power Consumption (2)
Below listed counters are currently available in SRAN8.0 version, but will be removed in a later version.
It is therefore not recommended to use them.
Counter ID / Description Measurement Point
Counter Name
1526727551 / Power consumption of the BBU The BBU power consumption is sampled every 5 minutes based on
VS.EnergyCons.BBU the power of all configured and detected boards in the BBU subrack.
At the end of a measurement period, the sum of these sampling
results is used as the value of the counter. Unit: kWh
1526727065 / Power consumption of the RRU/RFU The RRU or RFU power consumption is sampled every 5 minutes.
VS.EnergyCons.RRU At the end of a measurement period, the sum of these sampling
results is used as the value of the counter. Unit: kWh
1526727549 / total DC power consumption The power consumption of each PMU is sampled every 30 seconds.
VS.EnergyCons.PMU monitored by a power monitoring unit At the end of a measurement period, the sum of these sampling
(PMU) results is used as the value of the counter.
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 9
Report Table Demonstration in M2000-1
BS Traffic and Energy Consumption
How to get a graph:
1) Select the BTS to be displayed,
2) Display EC, traffic(select CS/PS/CS+PS),
3) List display each BTS’ data, or sum up all selected BTS
data,
4) Select part of BTS to display,
5) Save the graph and date to XLS/CSV file, so we can do
more analysis to the data.
Hourly axis
Data can be saved in XSL/CSV file which can be used for further analysis .
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 10
Report Table Demonstration in M2000-2
Bs Traffic and Energy Consumption Comparison
30 day application model
1st week, set ECM feature on, select BTS
phase I
2nd week, Energy saving features on
3th week, awaiting for EC after
energy saving actions phase II
4th week, M2000 GUI report table
Energy saving data analysis:
EE_I: phase I EE;
EE_II: phase II EE;
Traffic_sum(kbit): the annual total traffic throuput Energy saving data analysis
K=(Tariff/Kwh/3600/1000)
Annual grid fee saved=K* T_sum* (1/EE_I – 1/EE_II)
Power consumption saved while EE is improved.
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 11
Report Table Demonstration in PRS-1
PRS: BS Traffic and Energy Consumption Report
Application
Scenarios:
This function provides the
BTS energy consumption
Data zone data and traffic data in a
specified duration. More
specific relationship
between the BTS traffic
load and energy
consumption can be
Graph zone obtained from the BTS
energy consumption data
and traffic data.
M2000:BS Traffic and Energy Consumption PRS:BS Traffic and Energy Consumption
Time interval Hourly level Hourly/daily/weekly/monthly
Location M2000 PRS
Counter storage 30 days Days:180; Week:106; Month:36
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 12
Report Table Demonstration in PRS-2
Network Energy Efficiency Indicator
EE
throuput (t ) i
E.C _ BTS (t ) i
EE unit: bit/joule
Axis:
Daily
Weekly
Monthly
sample
Data can be saved in XLS file which can be used for further analysis .
HISILICONTECHNOLOGIES
HUAWEI SEMICONDUCTOR
CO., LTD. Page 13
Thank you
www.huawei.com