0% found this document useful (0 votes)
93 views

HP GND Air With APU Bleed AIRCOND Air With Air From Packs Simultaneously

The document provides a diagram and descriptions of an aircraft's avionics ventilation system. It includes labels for components like fans, valves, filters and air conditioning units. Caution notes provide information on using different air sources and what happens in failure cases. The diagram is complex with many interconnected components in the air ventilation system.

Uploaded by

Alex Alex
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views

HP GND Air With APU Bleed AIRCOND Air With Air From Packs Simultaneously

The document provides a diagram and descriptions of an aircraft's avionics ventilation system. It includes labels for components like fans, valves, filters and air conditioning units. Caution notes provide information on using different air sources and what happens in failure cases. The diagram is complex with many interconnected components in the air ventilation system.

Uploaded by

Alex Alex
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

BLEED AVIONICS VENTILATION CAUTION, do not use GND AIRCOND

CONFIGURATIONS: AIRCOND air with air from *PACK CTL


Prim fail => reg. not optimized
CAUTION, do not use CLOSED, on GND (skin<9°-12°C), in FLT(skin<32°-35°C) packs simultaneously
Sec fail => ECAM sgnal lost
HP GND air with APU bleed INTERMEDIATE if (skin>32°-35°C) then EXTRACT VLV partially opens
(IOM, JLP-S) Both fail => 5-30°C in 6’
OPEN, on GND (skin>9°-12°C) PACK 1 AIR COND SYS 1 CTL by a/ice vlv
SMOKE CONFIG FLOW *ZONE CTL
Regulated pressure 45 +/- 5 psi Air from avionics bay CONTROL *ZONE CTL
CABIN Prim fail => 24°C by packs
Leak detection FANs SPD (-IOM,-JLP-S) SKIN EXCH VALVE Sec fail => no effect
SKIN HEAT AIR
- single loop for APU and pylon ducts HI if T > 40°C [DC ESS *PACK 1 CTL Both fail => 20°C pack 1
OUTLET EXCHANGER SKIN
- double loop for wing ducts LO if T < 35°C SHED] 10°C pack 2
BYPASS VLV EXCH FILTER
AEVC ISOL CAB FAN 1
[DC1] VLV [AC1]
[DC ESS PACK
BLOWER COCKPIT EXTRACT 1 COCKPIT
SHED]
ENG A/ICE VALVE FAN PANELS FAN SKIN AIR
ENG 1 [DC1] SKIN AIR [AC1] [AC2] EXTRACT HOT AIR FLAP
INLET VLV AVIONICS VLV
ENG 2 [DC2] PRESS VALVE
EQPMT TRIM
valve opens if unpowered REG VLV
AIR VALVES
FILTER FWD
AIRCOND SKIN CABIN
INLET MIXING
EXCH UNIT
VALVE INLET
FAN AIR VALVE EMER
ENG 1 [DC ESS SHED] 5th BYPASS
VLV RAM AIR AIRCOND TRIM
ENG 2 [DC2] HP VLV, maintain 36+/-4 psi [DC ESS] GND
cargo AIR VALVES
regulates BLEED temp at 200°C 9th ENG 1 [DC ESS SHED] CONNECT
under-floor PACK 2
ENG 2 [DC2] FLOW
CONTROL AFT
BLEED MONITORING BLEED VALVE (ENG 1 only)
VALVE [DC2] PACK CABIN
COMPUTER ENG 1 [DC ESS SHED] pressure
BMC 1 [DC ESS SHED] ENG 2 [DC2] HYD WATER 2 CAB FAN 2
indication LOOP A
BMC 1 [DC2] RES TANK [AC2]
OVERPRESS LOOP B FILTER
VALVE (85psi) FF SATCOM
STARTER VLV *PACK 2 CTL
FF CABIN AIR
FF IOM, JLP-S
*ZONE CTL (85% recycle air)
temperature AIR COND SYS CTL
B1 one lane fail => no effect
indication X-BLEED VLV (IOM, JLP-S)
AUTOCTL [DC2] B2 AIR COND SYS 2 CTL both lanes fail => PACK lost
HOT BLEED MANCTL [DC ESS SHED]
COLD FAN AIR
COLD AIR FROM PACK
MIXED CONDITIONNED AIR
SAFETY
VALVES
PRESSURIZATION
MOT 1 CPC 1
- 2 safety valves (max 8.6psi or -.25psi)
WING ANTI ICE VLV [DC ESS] [DC ESS]
HP GND - RAM AIR ON and ∂p<1psi, outfl. vlv 50% opens
[AC ESS SHED]
Valve closes if unpowered CONNECT
MAN - CAB PR EXCESS CAB ALT (>9550+/-350ft)
MAN V/S
MOT
SWITCH
[DC BAT]
only SLATS 3,4 & 5
are heated OUTFLOW RPCU (IOM, JLP-S)
VALVE MOT 2 CPC 2 Depressurizes in case of residual press on GND
[DC2] [DC2]

APU ELECTRONIC
FWD
CARGO
SDCU (others)
CH1 [DC ESS SHED]
FIRE PROTECTION
LIMITATIONS
RPM min 95%, max 107% (auto shut down)
CONTROL BOX
[BAT]
APU
BLEED
COMP
A321 only CH2 [DC2]
& CARGO VENT
running EGT max 682°C (5sec) or 700-742 VALVE OUTLET ISOL SMOKE DETECTORS
start EGT max 900°C > 25'000ft VALVE SQUIBS
B CIDS (IOM, JLP-S)
start EGT max 982°C < 25'000ft EXTRACT FAN B [DC BAT] F FIRE DETECTORS
LOW OIL LEVEL => 10 hrs APU ops APU FF [AC1]
CH1 [DC ESS]
CH2 [DC2]
start cycles: S 1min S 1min S 60min APU B FIREX BOTTLES
Enveloppe: STARTER AFT
START with AC pwr up to 39'000ft [BAT] CARGO
A321 only ELECTRICAL SUPPLY
START with EMER ELEC pwr up to 25'000ft COMP
APU LP VLV ENG 1 loop A [DC ESS], loop B [DC2]
BLEED ON 2packs max 15'000ft, 1 pack max 20'000ft [DC BAT]
BLEED ON for engine start max 20'000ft BULK ENG 2 loop A [DC2], loop B [DC ESS]
[HOT 1] APU loop A & B[DC BAT]
BLEED for WING A/ICE not permitted INLET CARGO
APU FUEL FLOW ~130 kg/hr APU PUMP ISOL ENG 1&2 BTL 1 squib A [HOT1] squib B [HOT2]
VENTILATION
[DC BAT] P VALVE ENG 1&2 BTL 2 squib A [DC2] squib B [DC2]
CONTROL
[AC ESS APU BTL squib A [HOT1] squib B [DC BAT]
[DC BAT]
SHED] CABIN AMBIENT AIR APU auto extinguish [DC BAT]

FUEL A319/A320 refueling / defueling lines


feeding lines
FUEL EIU
A319: CFM56-5B6/2 23'500lbs
NOZZLES ENG1 [DC BAT]
A320: CFM56-5B4/2 27'000lbs
ENGINE
ENG2 [DC ESS]
A320E: CFM56-5B4/P 27'000lbs
TOTAL TANKS CAPACITY (den 0.785kg/l)
FF A321: CFM56-5B1/2 30'000lbs
CENTER TANK
18728kg / 19004kg (JLP-S) CENTER TANK
6476kg 6437kg
HP VLV [DC ESS] N1 100% = 5000 rpm
N2 100% = 14460 rpm
OUTER to INNER TRANSFER X-FEED FUEL METERING VLV TOGA EGT max 950° (5’, 10’OEI)
- XFR valves open when INNER have ~750kg MOT 1 [DC ESS SHED] IDG OIL COOLER ENG cool-down time 3' (1' for ops)
- T/O only with Outer TK full LP VALVE START cycle 4x(St.2’/20”) then 15’
MOT 2 [DC1] SERVO FUEL
- Automatic XFR after landing MOT 1 [DC ESS] ENG
HEATER IGNITION
(to avoid, switch REFUEL panel PWR ON!) MOT 2 [DC2] PMP FADEC
or transfer via DEFUEL/XFR valve. jet pump FUEL/OIL HEAT ENG1&2 CH A [DC ESS] ENG1&2 A [AC ESS]
1 or [AC STAT INV]
LP VALVE ENG1 CHB [DC BAT] ENG1 B [AC1]
DEFUEL ENG2 CHB [DC2]
MOT 1 [DC ESS] ENG2 B [AC2]
FQI INNER TANKS 1 2 XFR 1 2 MOT 2 [DC2]
CH1 [DC ESS SHED] XFR VALVES VLV
1 [DC ESS SHED] 2 x 5435kg* CENTER to WING TRANSFER
CH2 [DC2]
2 [DC2] 2 x 5573kg (JLP-S) A320 -Valve opens until wing tank is full then wait
A319 A321 until 250kg are used and re-opens
PUMP PUMP PUMP PUMP PUMP
- Gravity transfer from CTR TK
OUTER TANKS LH 1 LH 2 CTR1 RH 1 RH 2
CTR XFR [AC1] [AC2] WING TANKS only possible if >2000kg in
2 x 691kg REFUEL VALVE [AC1] [AC2] [AC1] VLV center tank these
[DC2] refueling on [DC1] [DC2] [DC1] [DC1] [DC2] 2 x 6084kg* REFUEL
are trapped
[DC ESS] L[DC1] [DC ESS] VALVE
batteries with
PUMP R[DC2] 2 x 6221kg (IOM)
[HOT1]
REFUEL
COUPLING
CTR2
[AC2] A321
REFUEL
COUPLING VENT TANK
FUEL IMBALANCE A319/A320 [DC2]
INNER TK Full, max 1500kg TOTAL CAPACITY ~50kg
INNER TK 4300kg, max 1600kg
TANK PUMPS WING PUMPS
(den 0.785kg/l) A321 FUEL IMBALANCE
INNER TK 2250kg, max 2250kg FUEL TEMPERATURE
no limitations below 2250kg
OUTER TK max 530kg, if OUTER+INNER same
JET A1 min -43°C max +54°C 18605kg WING TK Full, max 1350kg
WING TK 4000kg, max 1500kg
JET A min -36°C max +54°C
or INNER of empty OUTER equal or higher (up to 3t) of
opposite INNER
(IOM)18879kg WING TK 2350kg, max 2350kg
no limitations below 2350kg

* all others from type !!! NOT FOR OPERATIONAL USE !!! ©Pierre-Michel Gasser, 12.1.2013