HP GND Air With APU Bleed AIRCOND Air With Air From Packs Simultaneously
HP GND Air With APU Bleed AIRCOND Air With Air From Packs Simultaneously
APU ELECTRONIC
FWD
CARGO
SDCU (others)
CH1 [DC ESS SHED]
FIRE PROTECTION
LIMITATIONS
RPM min 95%, max 107% (auto shut down)
CONTROL BOX
[BAT]
APU
BLEED
COMP
A321 only CH2 [DC2]
& CARGO VENT
running EGT max 682°C (5sec) or 700-742 VALVE OUTLET ISOL SMOKE DETECTORS
start EGT max 900°C > 25'000ft VALVE SQUIBS
B CIDS (IOM, JLP-S)
start EGT max 982°C < 25'000ft EXTRACT FAN B [DC BAT] F FIRE DETECTORS
LOW OIL LEVEL => 10 hrs APU ops APU FF [AC1]
CH1 [DC ESS]
CH2 [DC2]
start cycles: S 1min S 1min S 60min APU B FIREX BOTTLES
Enveloppe: STARTER AFT
START with AC pwr up to 39'000ft [BAT] CARGO
A321 only ELECTRICAL SUPPLY
START with EMER ELEC pwr up to 25'000ft COMP
APU LP VLV ENG 1 loop A [DC ESS], loop B [DC2]
BLEED ON 2packs max 15'000ft, 1 pack max 20'000ft [DC BAT]
BLEED ON for engine start max 20'000ft BULK ENG 2 loop A [DC2], loop B [DC ESS]
[HOT 1] APU loop A & B[DC BAT]
BLEED for WING A/ICE not permitted INLET CARGO
APU FUEL FLOW ~130 kg/hr APU PUMP ISOL ENG 1&2 BTL 1 squib A [HOT1] squib B [HOT2]
VENTILATION
[DC BAT] P VALVE ENG 1&2 BTL 2 squib A [DC2] squib B [DC2]
CONTROL
[AC ESS APU BTL squib A [HOT1] squib B [DC BAT]
[DC BAT]
SHED] CABIN AMBIENT AIR APU auto extinguish [DC BAT]
* all others from type !!! NOT FOR OPERATIONAL USE !!! ©Pierre-Michel Gasser, 12.1.2013