Features (B)
Fiber
● High speed response: Max. 0.5ms Optic
Sensors
● Auto sensitivity setting (Button setting)/Remote sensitivity setting
● External synchronization input, mutual interference protection, self-diagnosis (C)
Door/Area
● Timer function: Selectable None / 40ms OFF Delay timer (fixed) (D)
(Standard type, remote sensitivity setting type only) Proximity
Sensors
Specifications (G)
External synchronization Remote sensitivity Connectors/
Standard type Sockets
Model input type setting type
BF4RP BF4GP BF4R BF4G BF4R-E BF4G-E BF4R-R BF4G-R
(H)
Light source Temperature
Red Green Red Green Red Green Red Green Controllers
(modulated light)
Power supply 12-24VDC ±10% (Ripple P-P: Max.10%)
(I)
Current consumption Max. 45mA SSRs / Power
Controllers
Operation mode Light ON/Dark ON switching
NPN or PNP open collector output
(J)
Control output ● Load voltage: Max. 30VDC ● Load current: Max. 100mA Counters
● Residual voltage - NPN: Max. 1V (load current: 100mA), Max. 0.4V (load current: 16mA) / PNP: Max. 2.5V
Protection circuit Reverse polarity protection circuit, short-circuit (overcurrent) protection circuit
(K)
Response frequency Max. 0.5ms (frequency 1), Max. 0.7ms (frequency 2) Timers
Sensitivity setting Sensitivity setting button (ON/OFF)
Indicator Operation indicator (OUT): Red LED, Stability indicator (STAB): Green LED (turns ON at stable light ON/OFF level) (L)
Panel
Interference Built-in differential frequency mode Meters
prevention function (frequency 1 (normal mode): max. 0.5ms, frequency 2: max. 0.7ms)
ON state under unstable sensing (when the target stays for 300ms in unstable level), (M)
Tacho /
ON state when control output is short-circuited Speed / Pulse
Self-diagnosis output Meters
● Load voltage: Max. 30VDC ● Load current: Max. 50mA
● Residual voltage - NPN: Max. 1V (load current: 50mA), Max. 0.4V (load current: 16mA) / PNP: Max. 2.5V (N)
Input of stop - Built-in -
Display
Units
transmission function
External Built-in (O)
synchronization - -
(Gate/Trigger) Sensor
function Controllers
Vibration 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 2 hours (R)
Graphic/
Shock 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Logic
Panels
Ambient Sunlight: Max. 11000㏓, Incandescent lamp: Max. 3000㏓ (received illumination)
illumination (S)
Environ- Ambient Field
-10 to 50℃, storage: -20 to 70℃ Network
ment temperature Devices
www.smartec-automacao.com.br
BF4 Series
Feature Data
Through-beam type Diffuse reflective type
● Measurement: BF4 (- )+ FT-420-10 ● Measurement: BF4 (- ) + FD-620-10
Parallel shifting characteristic Sensing area characteristic
180
600
Receiver ℓ1 150
500
120
400
300 90
L
ℓ1 200 60
L
100 30
0 0
200 100 0 -100 -200 30 20 10 0 -10 -20 -30
ℓ1 ℓ1
Emitter ℓ1 ℓ1
Left Center Right
Left Center Right
Sensing area (mm)
Sensing area (mm)
Main circuit
+ 12-24VDC +
Max. 100mA 12-24VDC
- ±10% (White) Load ※
- ±10%
(White) Self-diagnosis
output
Self-diagnosis output Load ※
Max. 50mA
(Blue)0V (Blue)0V
(Pink) (Pink)
Load ※
External Load ※ ON input of remote
synchronization input sensitivity setting
(Orange) (Orange)
※ + 12-24VDC + 12-24VDC
Main circuit
Load
Main circuit
www.smartec-automacao.com.br
Fiber Optic Amplifier
Connections (A)
Photoelectric
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(Brown) +V (Brown) +V
(D)
(Black) Control output Proximity
Load Sensors
(Black) Control output Load +
+ (White) Self-diagnosis output
12-24VDC±10% 12-24VDC±10%
(White) Self-diagnosis output Load (E)
- - Pressure
Load
Sensors
(Blue) 0V (Blue) 0V
(F)
● BF4R-E / BF4G-E ● BF4R-R / BF4G-R Rotary
Encoders
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
(Brown) +V (Brown) +V
(Pink) External synchronization input (Pink) ON input of remote sensitivity setting (I)
SSRs / Power
(Orange) Load (Orange) Load Controllers
Emission disable input Load + OFF input of remote sensitivity setting Load +
(Black) Control output 12-24VDC±10%
(Black) Control output 12-24VDC±10%
- (J)
-
(White) Self-diagnosis output (White) Self-diagnosis output
Counters
(Blue) 0V (Blue)0V
(K)
Timers
Dimensions
(L)
(unit: mm) Panel
Meters
(M)
Tacho /
12 62 Speed / Pulse
Meters
2-Ø2.4
(N)
Display
32.8
32.8
Units
7.3 8
(O)
Sensor
Ø4, 2m Controllers
16.4 36.5
3
(P)
Switching
Mode Power
● Connect the bracket Supplies
(Q)
Stepper Motors
& Drivers
12 & Controllers
(R)
2-Ø2.4 Graphic/
Logic
Panels
32.8
38
(S)
7.3 8
Field
Network
9
Devices
4
● Bracket
35
2 12
2
1
8.5
4
14 16
R1.6
27
www.smartec-automacao.com.br
BF4 Series
Installations
Mounting amplifier unit [Mounting] [Removing]
Hook the front part of the amplifier on DIN rail. Press the ①
②
rear part of the amplifier on DIN rail.
Push the back of amplifier toward ① and lift the hole for
fiber toward ② up then simply take it out without tools.
Fixing nut
※Notice: If setting bolt is tightened with over
specified tightening torque, hood of
fiber optic cable may be damaged.
Unit Description
● Standard type (BF4R/BF4RP/BF4G/BF4GP) ●E
xternal synchronization input type (BF4 -E)
Remote sensitivity setting type (BF4 -R)
1
2
3
www.smartec-automacao.com.br
Fiber Optic Amplifier
(B)
Fiber
Sensitivity setting Set/Relase the interference prevention function Optic
Sensors
prevention function
(E)
Pressure
Frequency 1 Frequency 2 Sensors
Press the [OFF] Press the [ON]
button at light OFF button at light OFF Press the [ON] Press the [OFF] (F)
button button Rotary
Encoders
(Frequency 1, (Frequency 2,
response time response time
: Max. 0.5ms) : Max. 0.7ms) (G)
The stability indicator [STAB] flashes once Connectors/
Sockets
when the difference of sensitivity between
ON and OFF is enough. (flashes 5 times
when the difference is not enough) The stability indicator (H)
[STAB] turns OFF Temperature
Controllers
SET (I)
Set the mode setting switch to [LOCK]. (Completes setting) SSRs / Power
LOCK Controllers
After completing the setting, do not move or bend the fiber optic cable. If not, it may cause incorrect detection.
Adjustment by the sensitivity setting button (Common) (K)
Timers
● Light ON ● Dark ON
The control output turns on at Light ON status and turns off The control output turns off at Light ON status and turns on (L)
at Light OFF status. at Light OFF status. Panel
Meters
www.smartec-automacao.com.br
BF4 Series
Setting as max. sensitivity (Common) Prohibition of inputting External
① Set the mode setting switch to [SET]. sensitivity setting[BF4 -R]
② If there is no sensing target, Even though mode switch is at Lock position, it is able to
- Light ON: Press the [ON → OFF] button input external sensitivity setting when Switch 1 and Switch
- Dark ON: Press the [OFF → ON] button 2 are ON. Therefore please install Switch 3 in order to
③ Set the mode selection switch to [LOCK] mode. prevent from malfunction as below.
※External sensitivity setting ※SW3 - OFF: Disable to set external sensitivity
- Light ON (From above ③) ※SW3 - ON: Enable to set external sensitivity
External sensitivity setting ON input (High→Low→High) (Brown) +V
External sensitivity setting OFF input (High→Low→High)
(Black) Control output
- Dark ON Mode (From above ③)
(White) Self-diagnosis output
External sensitivity setting OFF input
(Pink)ON input of remote sensitivity setting
(High→Low→High)
External sensitivity setting ON input (High→Low→High) (Orange)OFF input of remote
sensitivity setting
< Application >
● extend
o T sensing distance (diffuse reflective type): S/W3
If fiber optic sensor is used in place where there are (Blue)0V
targets with high reflectivity and low reflectivity, it is able S/W2 S/W1
to get stable detection by adjusting max. sensitivity. Switch for prohibiting sensitivity setting
● Used at bad environment (through-beam type):
If fiber optic sensor is used in place where there is lots of Self-diagnosis output (answer back)
dust or moisture, it might cause malfunction. function[BF4 -R]
It can perform the stable detection by using max.
When ON or OFF input of remote sensitivity setting is
sensitivity.
applied, after 300ms, self-diagnosis output turns on for
Remote sensitivity adjustment[BF4 -R] 40ms and then the sensor keeps normal sensing state.
Remote sensitivity setting type, BF4 -R can adjust the (Note: Time chart)
sensitivity with input signal lines without the mode setting ※Self-diagnosis output does not turn on if there is no
switch. difference of sensitivity between ON input and OFF input
(Brown) +V and stable sensing is not executed, but stable sensing
(Black) Control output
operates after 340ms.
(White) Self-diagnosis output <Time Chart: Light ON mode >
(Pink)ON input of remote sensitivity setting
Power ON
(Orange)OFF input of remote
sensitivity setting supply
OFF
S/W2 S/W1
(Blue)0V Remote
High T1 T2
sensitivity
(OFF)
setting
ON input Low
● Light ON (ON)
www.smartec-automacao.com.br
Fiber Optic Amplifier
Standard type and Remote sensitivity setting type both This function is available under light ON state only and it is (B)
Fiber
contain the built-in OFF Delay timer, approx. 40ms. The for checking normal state of the sensor. Optic
Sensors
timer works when the timer selection switch is set to [OFD].
The output turns off after remaining for additional 40ms at (C)
Door/Area
OFF position of the sensing output. It is useful when the (Orange)Input of stop transmission Sensors
ON (F)
Light Rotary
ON OFF Encoders
(Orange)Input of stop transmission
Normal
(G)
ON Low Connectors/
Dark Sockets
OFF
ON
(Blue)0V
(H)
Temperature
ON T T T [If input of stop transmission is at Low, light is transmitted.] Controllers
Light
ON OFF ① ① ① ①
High (I)
Input of stop (OFF) SSRs / Power
Timer
② ② ② Controllers
ON T transmission Low
Dark (ON) T T T
ON OFF
(J)
Sensing output Counters
ON ※1
(If it is in ON
OFF
state when light
External Synchronization Input is not received)
Normal Abnormal
(K)
Timers
synchronization. (trigger synchronization and gate on, but if control output does not turn on, it seems that (M)
synchronization) sensor has some problems. Tacho /
Speed / Pulse
www.smartec-automacao.com.br
BF4 Series
Operation
Light
ON level
level
Unstable light
OFF level
① Set the mode setting switch to [SET].
Stable light ② Press the [ON] + [OFF] buttons for
OFF level
L 2 sec. at the same time.
Control output ON
indicator ③ The Stability indicator [STAB] flashes
(red LED) OFF
Stability ON continuously.
indicator OFF
(green LED) 300ms ① 300ms ① ④ Press the [ON] button.
Self-diagnosis ON
output OFF ⑤ The Stability indicator [STAB] turns off.
● When detecting state remains over 300ms at unstable light
ON/OFF level, the self diagnosis output turns ON. In case
of stable light ON/OFF level, the self diagnosis output turns
OFF. (① position)
Flashing
Flashing
SMARTEC AUTOMACAO
Rua Equador, 25 - Santo André - SP
Phone: 4425-5103 / 2759-8615
www.smartec-automacao.com.br