0% found this document useful (0 votes)
88 views9 pages

Honeywell NT Series Sealed Toggle Switches

This document provides information about an interactive catalog that supplements paper catalogs for a company's sensing and control products. The interactive catalog allows users to access more complete and up-to-date product information through searching compared to the paper catalogs. It includes extensive specifications, application data, and technical literature that can be searched based on user-selected criteria. This summary is intended to highlight the key purpose and functionality of the interactive catalog being described.

Uploaded by

Puti Benny Lakra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views9 pages

Honeywell NT Series Sealed Toggle Switches

This document provides information about an interactive catalog that supplements paper catalogs for a company's sensing and control products. The interactive catalog allows users to access more complete and up-to-date product information through searching compared to the paper catalogs. It includes extensive specifications, application data, and technical literature that can be searched based on user-selected criteria. This summary is intended to highlight the key purpose and functionality of the interactive catalog being described.

Uploaded by

Puti Benny Lakra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Interactive Catalog Supplements Catalog PDFs

If you need detailed product information, or help choosing the right


product for your application, see our Interactive Catalog. Use the Sensing and Control
Interactive Catalog to access the most complete and up-to-date Interactive
information available.
Catalog...
The Interactive Catalog provides an extensive collection of product
specifications, application data, and technical literature that can be Click this icon to try
searched based on criteria you select. the Interactive Catalog.

This PDF catalog information was published in November 2000.

Sensing and Control


Honeywell Inc.
11 West Spring Street
Freeport, IL 61032
www.honeywell.com/sensing
Manual Switches NT Series
Sealed Toggle Switches
FEATURES
1 Completely sealed switching
chamber
1 Step-design case provides added
space between terminals to help
prevent shorting
1 1, 2 or 4-pole circuitry
1 Standard and pull to unlock levers.
1 2 or 3 positions, maintained and
momentary action
1 Spring-loaded actuating mechanism
provides excellent tactile feedback
1 High impact strength, non-tracking
case enhances electrical stability
1 Temperature range: –40 to 71°C
CONSTRUCTION (–40 to 160°F)
1 UL recognized, File E12252, Vol. 1,
Section 44
1 CSA certified, File LR4442
1 CE approved

GENERAL INFORMATION
MICRO SWITCH NT Series toggle switch-
es meet severe environment application
needs for a rugged, cost-effective toggle
switch. Quality construction features in-
clude a molded-in elastomer seal be-
tween the toggle lever and bushing, and
between the cover and case. In addition,
the terminal inserts are molded into the
high impact strength thermoplastic case.

Complete sealing of the switching cham-


ber enables NT toggles to comply with UL
508, paragraph 13.3 hosedown test.
These switches can be used where pan-
UL AND CSA ELECTRICAL RATINGS els are subjected to periodic splash and
Rating Code* Electrical Rating washdowns, such as are common to food
and beverage equipment. They will also
L192 10 amps, 125, 250, 277 VAC; 1⁄4 Hp, 125 VAC; 1⁄2 Hp, 250, 277 VAC; 3 amps,
withstand exposure to heavy accumula-
125 VAC ‘‘L’’
tions of early morning dew that may con-
L191 15 amps, 125, 250, 277 VAC; 1⁄2 Hp, 125 VAC; 1 Hp, 250, 277 VAC; 5 amps, dense on the control panel in cabs of
125 VAC ‘‘L’’ vehicles left outdoors overnight.
* Referred to in order guides.
PULL-TO-UNLOCK LEVERS
ELECTRICAL RATINGS Pull-to-unlock toggle levers prevent acci-
dental toggle movement. The knobbed
In Amperes toggle lever must be pulled out approxi-
115 Volts AC mately .09 in. (2,3 mm) to change posi-
Elect.
28 Volts DC 115 VDC 250 VDC 60 & 400 Hz 230 VAC tions. Thirteen different locking configu-
Rating
Code Ind. Res. Lamp Res. Res. Ind. Res. Lamp Res. rations are available. This lever style also
has a non-glare matte nickel finish.
1 12 20 5 0.75 0.5 10 15 3 6
2 10 15 4 0.75 0.5 7 15 2 6
3 15 20 7 0.75 0.5 15 15 4 6
4 10 18 5 0.75 0.5 8 11 2 6
5 12 20 5 0.75 0.5 15 15 4 6
6 10 18 4 0.75 0.5 8 11 2 6

Application Note: Honeywell MICRO SWITCH does not recommend the use of
silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are
generally loads less than 12 volts and/or 0.5 amp. NT switches use silver cadmium
oxide contacts. For other options, contact the MICRO SWITCH Application Center at
1-800-537-6945.

108 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Manual Switches NT Series
Sealed Toggle Switches
NT 2-POSITION ORDER GUIDE

Circuits Made With Toggle At: Pull-To-Unlock


No. UL Elect. Standard Lever Lever (Add suffix
of Keyway Opposite Rating Rating Termination Style to Standard Lever
Poles Position Keyway Code Code Screw Solder Q-C Listing)
OFF 2-3 L191 1 1NT1-2 11NT1-2 1NT91-2 D, F, G
1 1-2 2-3 L191 1 1NT1-3 11NT1-3 1NT91-3 D, F, G
OFF* 2-3 L192 2 1NT1-4 11NT1-4 1NT91-4 F
1-2* OFF L192 2 1NT1-6 11NT1-6 1NT91-6 F
1-2* 2-3 L192 2 1NT1-8 11NT1-8 1NT91-8 F
OFF 2-3, 5-6 L191 3 2NT1-2 12NT1-2 2NT91-2 D, F, G
2 1-2, 4-5 2-3, 5-6 L191 3 2NT1-3 12NT1-3 2NT91-3 F
OFF* 2-3, 5-6 L192 4 2NT1-4 12NT1-4 2NT91-4 F
1-2, 4-5 * OFF L192 4 2NT1-6 12NT1-6 2NT91-6 D, F, G
1-2, 4-5 * 2-3, 5-6 L192 4 2NT1-8 12NT1-8 2NT91-8 F
OFF 2-3, 5-6, 8-9, 11-12 L191 5 4NT1-2 14NT1-2 4NT91-2 D, F, G
4 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 L191 5 4NT1-3 14NT1-3 4NT91-3 F
OFF* 2-3, 5-6, 8-9, 11-12 L192 6 4NT1-4 14NT1-4 4NT91-4 F
1-2, 4-5, 7-8, 10-11 * OFF L192 6 4NT1-6 14NT1-6 4NT91-6 D, F, G
1-2, 4-5, 7-8, 10-11 * 2-3, 5-6, 8-9, 11-12 L192 6 4NT1-8 14NT1-8 4NT91-8 F

NT 3-POSITION ORDER GUIDE

Circuits Made With Toggle At: Pull-To-Unlock


No. UL Elect. Standard Lever Lever (Add suffix
of Keyway Center Opposite Rating Rating Termination Style to Standard
Poles Position Position Keyway Code Code Screw Solder Q-C Lever Listing)
1-2 OFF 2-3 L191 1 1NT1-1 11NT1-1 1NT91-1 ALL TYPES
1 1-2* OFF 2-3 L192 2 1NT1-5 11NT1-5 1NT91-5 E, F, K, L, M, N
1-2* OFF 2-3* L192 2 1NT1-7 11NT1-7 1NT91-7 E, L, N
NONE** OFF 2-3 L191 1 1NT1-21 11NT1-21 1NT91-21 E, F, K, M
NONE** 1-2 2-3 L191 1 1NT1-31 11NT1-31 1NT91-31 E, F, K, M
NONE** 1-2 2-3* L192 2 1NT1-51 11NT1-51 1NT91-51 E
1-2* OFF NONE** L192 2 1NT1-61 11NT1-61 1NT91-61 E
1-2, 4-5 OFF 2-3, 5-6 L191 3 2NT1-1 12NT1-1 2NT91-1 ALL TYPES
2 1-2, 4-5 * OFF 2-3, 5-6 L192 4 2NT1-5 12NT1-5 2NT91-5 E, F, K, L, M, N
1-2, 4-5 * OFF 2-3, 5-6* L192 4 2NT1-7 12NT1-7 2NT91-7 E, L, N
NONE* OFF 2-3, 5-6 L191 3 2NT1-21 12NT1-21 2NT91-21 E, F, K, M
NONE** 1-2, 4-5 2-3, 5-6 L191 3 2NT1-31 12NT1-31 2NT91-31 E, F, K, M
NONE** 1-2, 4-5 2-3, 5-6* L192 4 2NT1-51 12NT1-51 2NT91-51 E
1-2, 4-5 * OFF NONE** L192 4 2NT1-61 12NT1-61 2NT91-61 E
1-2, 4-5 2-3, 4-5 2-3, 5-6 L191 3 2NT1-12 12NT1-12 2NT91-12 ALL TYPES
1-2, 4-5 1-2, 5-6 2-3, 5-6 L191 3 2NT1-10 12NT1-10 2NT91-10 ALL TYPES
1-2, 4-5 * 1-2, 5-6 2-3, 5-6 L192 4 2NT1-50 12NT1-50 2NT91-50 L, F, K, L, M, N
1-2, 4-5 * 1-2, 5-6 2-3, 5-6* L192 4 2NT1-70 12NT1-70 2NT91-70 E, L, N
1-2, 4-5, 7-8, OFF 2-3, 5-6, 8-9, L191 5 4NT1-1 14NT1-1 4NT91-1 ALL TYPES
10-11 11-12
4 1-2, 4-5, 7-8, OFF 2-3, 5-6, 8-9, L192 6 4NT1-5 14NT1-5 4NT91-5 E, F, K, L, M, N
10-11* 11-12
1-2, 4-5, 7-8, OFF 2-3, 5-6, 8-9, L192 6 4NT1-7 14NT1-7 4NT91-7 E, L, N
10-11* 11-12*
NONE* OFF 2-3, 5-6, 8-9, L191 5 4NT1-21 14NT1-21 4NT91-21 E, F, K, M
11-12
Toggle/Rockers

NONE** 1-2, 4-5, 7-8, 2-3, 5-6, 8-9, L191 5 4NT1-31 14NT1-31 4NT91-31 E, F, K, M
10-11 11-12
NONE** 1-2, 4-5, 7-8, 2-3, 5-6, 8-9, L192 6 4NT1-51 14NT1-51 4NT91-51 E
10-11 11-12*
1-2, 4-5, 7-8, OFF NONE** L192 6 4NT1-61 14NT1-61 4NT91-61 E
10-11*
1-2, 4-5, 7-8, 2-3, 4-5, 7-8, 2-3, 5-6, 8-9, L191 5 4NT1-12 14NT1-12 4NT91-12 ALL TYPES
10-11 11-12 11-12
1-2, 4-5 2-3, 4-5 2-3, 5-6 L191 5 4NT1-10 14NT1-10 4NT91-10 ALL TYPES
7-8, 10-11 8-9, 11-12
1-2, 4-5, 7-8, 2-3, 4-5, 7-8, 2-3, 5-6, 8-9, L192 6 4NT1-50 14NT1-50 4NT91-50 E, F, K, L, M, N
10-11 * 11-12 11-12
1-2, 4-5, 7-8, 2-3, 4-5 2-3, 5-6, 8-9, L192 6 4NT1-70 14NT1-70 4NT91-70 E, L, N
10-11* 11-12*
* These positions are momentary. All others are maintained.
** Toggle lever is blocked from these products. Toggle becomes 2-position, with center being one extreme position.

Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 109
Manual Switches NT Series
Sealed Toggle Switches
PULL-TO-UNLOCK OPTION
When ordering pull-to-unlock toggle list- der a INTI-1 pull-to-unlock toggle switch
ings, add the suffix letter shown in the with the lever locked in the center posi-
chart below to the standard toggle listing tion, add the letter E; i.e., INTI-1E.
and the MS number. For example, to or-

LOCKING CONFIGURATIONS
A B D E F G H

Locked In Locked Out Of


Center and Locked Out Locked In Locked In Center And
Locked In Extreme Position Of Center Locked In Extreme Position Extreme Position Extreme Position
Three Positions (Keyway Side) Position Center Position (Opposite Keyway) (Keyway Side) (Keyway Side)
J K L M N P

Locked Out Of Locked In Locked Out Of Locked Out Of


Center And Center And Locked Out Of And Into Locked Out Of And Into
Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position
(Opposite Keyway) (Opposite Keyway) (Keyway Side) (Opposite Keyway) (Opposite Keyway) (Keyway Side)

MOUNTING DIMENSIONS:
(For reference only) 0,0 = mm
Key: 0.00 = inches

Panel cutout

With locking ring Without locking ring

Note:
0 1,4/.06 MIN DEEP TO ACCOMMODATE LOCKING
RING. 15PA87 PANEL SEAL REQUIRES BLIND HOLE
DIM ‘‘A’’ TO INSURE SEAL INTEGRITY
1-pole 29,5/1.16
2 & 4-pole 34,4/1.35
NOTES: Terminal Circuit Identification
1. Pull-to-unlock levers have 10,7/42 dia. knob
2. Locking ring, lockwasher, 2 hexnuts and terminal screws are
furnished unassembled.

Solder Terminals

Bushing mounting
torque is 10–15
in./lbs.
Terminal screw
Quick Connect Terminals mounting torque is 5
in./lbs. max.

110 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
This page intentionally left blank.

Toggle/Rockers

Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 111
Manual Switches NT Series
Flat Base Sealed Toggles and Rockers
FEATURES
1 Sealed switching chamber
1 1 or 2-pole circuitry
1 2 or 3 position maintained and
momentary action
1 Flat base with quick-connect
terminals – mating connectors are
available
1 Spring-loaded actuating mechanism
provides tactile feedback
1 High impact strength, non-tracking
case enhances electrical stability
1 Temperature range: –40 to 71°C (–40
to 160°F)
1 UL Recognized, File E12252, vol. 1,
section 44
1 CSA Certified, File LR4442
UL AND CSA ELECTRICAL RATINGS 1 CE approved
Rating Code* Electrical Rating
L192 10 amps, 125, 250, 277 VAC; 1⁄4 Hp, 125 VAC; 1⁄2 Hp, 250, 277 VAC; 3 amps, GENERAL INFORMATION
125 VAC ‘‘L’’ MICRO SWITCH NT Series toggle switches
are designed to meet severe environment
L191 15 amps, 125, 250, 277 VAC; 1⁄2 Hp, 125 VAC; 1 Hp, 250, 277 VAC; 5 amps,
application needs for rugged, cost-effective
125 VAC ‘‘L’’
manual switches. These flat base style
products are identical to the stepped
ELECTRICAL RATINGS base style in construction and features.

In Amperes The flat base allows for PC board or con-


115 Volts AC nector use for easy wiring/connection.
28 Volts DC 115 VDC 250 VDC 60 & 400 Hz 230 VAC The flat base NT toggle switches are
Rating
provided with quick-connect (spade)
Code Ind. Res. Lamp Res. Res. Ind. Res. Lamp Res.
termination. Mating connectors are
1 12 20 5 0.75 0.5 10 15 3 6 available.
2 10 15 4 0.75 0.5 7 15 2 6
3 15 20 7 0.75 0.5 15 15 4 6
TERMINAL CIRCUIT IDENTIFICATION
4 10 18 5 0.75 0.5 8 11 2 6
Terminal identifications are referenced in
the order guides to indicate which circuits
Application Note: Honeywell MICRO SWITCH does not recommend the use of silver are made in each toggle position (e.g.
cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally ‘‘1-2’’ refers to circuit closure through ter-
loads less than 12 volts and/or 0.5 amp. NT switches use silver cadmium oxide minals 1 and 2).
contacts. For other options, contact the MICRO SWITCH Application Center at
1-800-537-6945.

112 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Manual Switches NT Series
Flat Base Sealed Toggles
NT 2-POSITION ORDER GUIDE

Circuits Made At:


Catalog
No. of Keyway Opposite UL Rating Electrical Listing
Poles Position Keyway Code Rating Code Toggle Q-C
OFF 2-3 L191 1 31NT91-2
1 1-2 2-3 L191 1 31NT91-3
OFF** 2-3 L192 2 31NT91-4
1-2** OFF L192 2 31NT91-6
1-2** 2-3 L192 2 31NT91-8
OFF 2-3, 5-6 L191 3 32NT91-2
2 1-2, 4-5 2-3, 5-6 L191 3 32NT91-3
OFF** 2-3, 4-6 L192 4 32NT91-4
1-2, 4-5** OFF L192 4 32NT91-6
1-2, 4-5** 2-3, 4-6 L192 4 32NT91-8

NT 3-POSITION ORDER GUIDE

Circuits Made At: Electrical Catalog


No. of Keyway Center Opposite UL Rating Rating Listing
Poles Position Position Keyway Code Code Toggle Q-C
1-2 OFF 2-3 L191 1 31NT91-1
1 1-2** OFF 2-3 L192 2 31NT91-5
1-2** OFF 2-3** L192 2 31NT91-7
NONE*** OFF 2-3 L191 1 31NT91-21
NONE*** 1-2 2-3 L191 1 31NT91-31
NONE*** 1-2 2-3** L192 2 31NT91-51
1-2** OFF NONE*** L192 2 31NT91-61
1-2, 4-5 OFF 2-3, 5-6 L191 3 32NT91-1
2 1-2, 4-5** OFF 2-3, 5-6 L192 4 32NT91-5
1-2, 4-5** OFF 2-3, 5-6** L192 4 32NT91-7
NONE*** OFF 2-3, 5-6 L191 3 32NT91-21
NONE*** 1-2, 4-5 2-3, 5-6 L191 3 32NT91-31
NONE*** 1-2, 4-5 2-3, 5-6** L192 4 32NT91-51
1-2, 4-5** OFF NONE*** L192 4 32NT91-61
1-2, 4-5 2-3, 4-5 2-3, 5-6 L191 3 32NT91-12
1-2, 4-5 1-2, 5-6 2-3, 5-6 L191 3 32NT91-10
1-2, 4-5** 1-2, 5-6 2-3, 5-6 L192 4 32NT91-50
1-2, 4-5** 1-2, 5-6 2-3, 5-6** L192 4 32NT91-70
** These positions are momentary. All others are maintained.
*** Toggle lever is blocked from these positions. Toggle becomes 2-position, with center being one extreme
position.

MATING CONNECTORS ORDER GUIDE

Description Catalog Listing


2-pole connector 19PA168-NT
1-pole connector, same package size as 2-pole connector 19PA169-NT

LOCKING CONFIGURATIONS
A B D E F G H
Toggle/Rockers

Locked In Locked Out Of


Center and Locked Out Locked In Locked In Center And
Locked In Extreme Position Of Center Locked In Extreme Position Extreme Position Extreme Position
Three Positions (Keyway Side) Position Center Position (Opposite Keyway) (Keyway Side) (Keyway Side)
J K L M N P

Locked Out Of Locked In Locked Out Of Locked Out Of


Center And Center And Locked Out Of And Into Locked Out Of And Into
Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position
(Opposite Keyway) (Opposite Keyway) (Keyway Side) (Opposite Keyway) (Opposite Keyway) (Keyway Side)

Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 113
This page intentionally left blank.

114 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Manual Switches NT Series
Flat Base Sealed Toggles and Rockers
MOUNTING DIMENSIONS (For reference only)

Toggle Switches

Bushing mounting torque is 10–15 in./lbs.


Toggle/Rockers

Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 115