PMI-SLE
RECTILINEAR DISPLACEMENT TRANSDUCER WITH
MAGNETIC DRAG (analog output)
TECHNICAL DATA
Useful electrical stroke (C.E.U.)
50/100/150/200/250/300/350/400/450/500/550/600/750/800/850/900/950
/1000
Independent linearity (within C.E.U.)
± 0,35%
Resolution
Infinite
Repeatability
≤ 0.08 mm
Hysteresis
< 250µm
Life
> 25x106 m strokes, or > 100x106 maneuvers, whichever is less
Applicative characteristics Displacement sensitivity (no hysteresis))
• The PMI-SLE transducer, is the amplified version of from 0.05 to 0.1 mm
the PMI-SL, a product designed for all inside cylinder Tracking error
applications which require a smaller transducer (the see table
rod diameter is only 12,7 mm). Displacement speed
• The PMI Slim offers the same robustness: stainles- standard < 5 m/s
steel body, IP67 protection level, and pressure resi- Max. acceleration
stance up to 250 bar (400 bar peak) < 10m/s2 max displacement
• Available with flanged or threaded heads, to guaran- Cursor dragging force
tee mechanical compatibility with all main cylinder ≤ 0.5 N
types Vibrations
• Patented solution 5...2000Hz, Amax =0,75 mm amax. = 20 g
• Ideal for applications inside hydraulic cylinders,
Shock
demanding simple solutions which guarantee measu-
50 g, 11ms.
rement repeatability.
Power supply voltage
10...30Vdc (see the load diagram)
Max power consumption
MECHANICAL DIMENSION 35mA
Min load allowed
Version Flange (X) Std see the load diagram
Output signal 4...20 mA
- ZERO position (4mA): between 1% and 3% of the C.E.U.
3-pole
cable PUR
SEALING
ZONE
- SPAN position (20mA): between 96% and 99% of the C.E.U.
IP67 0,2 BAR
Electrical connection
Sealing 1 mt. 3-pole shielded cable
gasket
Sampling time
Case
≤ 1 ms
Welding
Noise on output
SEALING
ZONE < 0.08%FS RMS
AT 250 BAR
Version Flange (M) Electrical isolation
M24x1,5 thread
> 100 MΩ at 45 Vdc = 1 bar, 2 s
Zero and FSO temperature drift
3-pole
cable PUR < 0.02%FS/°C
Polarity inversion protection
Yes
Pulse overvoltage protection
Yes
Working temperature
-30...+80°C
Storage temperature
-40...+100°C
Protection level
Stem
IP67
Welding
Material for transducer case
Steel AISI 304
MECHANICAL / ELECTRICAL DATA
MODEL 50 100 150 200 250 300 350 400 450 500 550 600 750 800 850 900 950 1000
Useful electrical stroke (C.E.U.) + 1/-0 mm Model
Theoretical electrical stroke (C.E.T.) ± 1 mm C.E.U. + 1
Independent linearity (within C.E.U.) ±% 0.35
Mechanical stroke (C.M.) mm C.E.U. + 5
Lenght “A” ±1 mm C.E.U. + 100.2
PCUR010 CURSOR STANDARD FLANGE (X) THREADED FLANGE (M)
Stem Stem
Welding
Welding
INSTALLATION INSIDE THE CYLINDER
O-Ring recommended
PARKER 2-117 20,29x2,62
Material NBR 90 Shore-A
Compound PARKER N552-90
Flange Version (M) thread M24x1,5
O-ring surface must be free of spiral
or longitudinal scratches Ro 1,6μm for
O-rings with NOT PULSING pressure
Ro 0,8μm for O-rings with PULSING
pressure
O-Ring recommended PARKER 2-117
20,29x2,62 Material NBR 90 Shore-A
Compound PARKER N552-90
INSTALLATION INSIDE THE CYLINDER
Groove in cylinder shaft, for OR Seal
Cylinder shaft assembly of cursor, corrugated recommended:
washers and snap ring OR119 NBR-90
Locking
Potentiometer No. 2 corrugated washers must be Cursor screw
Flange Version (X) standard rod assembled in a pack so to prevent
any axial movements of cursor and
to allow cursor to rotate toward Snap ring
piston shaft
Non-magnetic spacer
thickness 2 + -0.1
Non-magnetic spacer Cursor
thickness 2 + -0.1
Cursor housing size PMI-SL assembly with
corrugated washers and non-magnetic spacer
Cursor assembly PMI-SL with thickness 2+-0.1
screws and magnetic spacer
ELECTRICAL CONNECTIONS
CONTROLLER
Supply +
brown INSTALLATION INSTRUCTIONS
Supply -
blue • Respect the indicated electrical connections
Output -
AMPLIF.
• When calibrating the transducer, be careful to set the stroke
Output +
yellow so that the output does not drop below 1% or rise beyond
99% of the 4/20mA output.
Connection
side
Connected to the transducer’s housing
(do not connect to the panel side)
TRACKING ERROR LOAD DIAGRAM
2
1000
1,8
900
1,6
800
1,4
Load (Ohm)
700
Error (mm)
1,2 600
1 500
0,8 400 Area of use
300
0,6
200
0,4
100
0,2
0
10 12 14 16 18 20 22 24 26 28 30
2 4 6 8 10 12 14 16 18 20 22
Acceleration (g) Power supply (V)
ACCESSORIES (series)
Standard magnetic cursor PCUR010
ORDERING CODE
Displacement
P M I S L E 0 0 0 0 X 0 0 0 X X X X X
transducer
No certificate attached 0 Version F cable length
4...20mA analog output
Linearity curve to be attached L 1 mt cable (standard) 00
3-pole PUR cable output 2 mt cable 02
F
3x0.25, 1 mt 3 mt cable 03
4 mt cable 04
Model 5 mt cable 05
10 mt cable 10
Standard flange X
15 mt cable 15
Threaded flange M24x1.5 M
Ex.: PMI-SLE-F-0400-X 0000X000XX00XXX
PMI SLE displacement transducer, 4...20mA analog output, useful electrical stroke (C.E.U.) 400mm, standard flange, no certificate attached,
cable length 1 mt.
Sensors are manufactured in compliance with:
- EMC 2004/108/CE compatibility directive
- RoHS 2002/95/CE directive
Electrical installation requirements and Conformity certificate are available on our web site: www.gefran.com
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice.
GEFRAN spa
via Sebina, 74
25050 PROVAGLIO D’ISEO (BS) - ITALIA
ph. 0309888.1 - fax. 0309839063
Internet: http://www.gefran.com DTS_PMI-SLE_03-2016_ENG