0% found this document useful (0 votes)
93 views1 page

Assay Values and Ranges Overview

This document provides the assay values and expected ranges for 3 controls - low, normal, and high - across multiple hematology parameters such as WBC, RBC, Hgb, Hct, MCV, MCH, and platelet counts. The controls are from lot number 1S0601 and were tested on instruments from Rayto and Tulip. For each parameter, the mean value, standard deviation, and expected value range are given based on previous testing results. This information serves as a reference for evaluating assay performance and accuracy.

Uploaded by

Nice Benny
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views1 page

Assay Values and Ranges Overview

This document provides the assay values and expected ranges for 3 controls - low, normal, and high - across multiple hematology parameters such as WBC, RBC, Hgb, Hct, MCV, MCH, and platelet counts. The controls are from lot number 1S0601 and were tested on instruments from Rayto and Tulip. For each parameter, the mean value, standard deviation, and expected value range are given based on previous testing results. This information serves as a reference for evaluating assay performance and accuracy.

Uploaded by

Nice Benny
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

D-Check D

CONTROL

ASSAY VALUES AND EXPECTED RANGES LOT: 1S0901


1S0601
05-12-2019
05-03-2020
05-03-2020
05-03-2020

Instruments: Rayto RT-7600S,Tulip


Hemax Councell-23
330 Plus
CONTROL "Low" CONTROL "Normal" CONTROL "High"
LOT: 1S0601 LOT: 1S0601 LOT: 1S0601
Parameter
Range Range Range
Mean ± Limit Mean ± Limit Mean ± Limit
Variation Variation Variation
WBC 3 9
10 /mL & 10 /L 2,53 ± 0,50 2,03 - 3,03 6,99 ± 1,00 5,99 - 7,99 17,06 ± 2,50 14,56 - 19,56

RBC 106/mL & 1012/L 2,36 ± 0,20 2,16 - 2,56 4,65 ± 0,30 4,35 - 4,95 5,52 ± 0,40 5,12 - 5,92

Hgb g/dL 7,1 ± 0.6


0,5
6 6,6 - 7,6 14,2 ± 0,6 13,6 - 14,8 18,2 ± 0,8 17,4 - 19,0

g/L 71 ± 5 66 - 76 142 ± 6 136 - 148 182 ± 8 174 - 190

Hct % 20,5 ± 3,0 17,5 - 23,5 42,7 ± 4,0 38,7 - 46,7 53,8 ± 4,5 49,3 - 58,3

L/L 0,205 ± 0,030 0,175 - 0,235 0,427 ± 0,040 0,387 - 0,467 0,538 ± 0,045 0,493 - 0,583

MCV fL 86,7 ± 6,0 80,7 - 92,7 91,8 ± 6,0 85,8 - 97,8 97,6 ± 6,0 91,6 - 103,6

MCH pg 30,2 ± 3,8 26,4 - 34,0 30,4 ± 3,8 26,6 - 34,2 33,0 ± 3,8 29,2 - 36,8

MCHC g/dL 34,9 ± 4,8 30,1 - 39,7 33,1 ± 4,8 28,3 - 37,9 33,8 ± 4,8 29,0 - 38,6

g/L 349 ± 48 301 - 397 331 ± 48 283 - 379 338 ± 48 290 - 386

RDW-CV % 18,7 ± 5,0 13,7 - 23,7 16,3 ± 5,0 11,3 - 21,3 14,3 ± 5,0 9,3 - 19,3

Plt 3 9
10 /mL & 10 /L 107 ± 25
30 82 - 132 269 ± 45 224 - 314 529 ± 75 454 - 604

MPV fL 8,21 ± 3,00 5,21 - 11,21 9,26 ± 3,00 6,26 - 12,26 9,56 ± 3,00 6,56 - 12,56

PDW % 11,86 ± 3,00 8,86 - 14,86 12,84 ± 3,00 9,84 - 15,84 8,47 ± 3,00 5,47 - 11,47

PCT % 0,069 ± 0,050 0,019 - 0,119 0,259 ± 0,100 0,159 - 0,359 0,540 ± 0,200 0,340 - 0,740

P-LCR % 33,7 ± 8,0 25,7 - 41,7 34,8 ± 7,0 27,8 - 41,8 34,6 ± 7,0 27,6 - 41,6

LYMPH# 103/mL & 109/L 1,38 ± 0,41 0,97 - 1,79 2,00 ± 0,70 1,30 - 2,70 3,36 ± 1,85 1,51 - 5,21

MID# 3 9
10 /mL & 10 /L 0,14 ± 0,13 0,01 - 0,27 0,45 ± 0,36 0,09 - 0,81 0,71 ± 0,53 0,18 - 1,24

GRAN# 103/mL & 109/L 1,01 ± 0,41 0,60 - 1,42 4,54 ± 0,68 3,86 - 5,22 12,99 ± 3,90 9,09 - 16,88

LYMPH% % 54,3 ± 13,6 40,7 - 67,9 28,6 ± 10,0 18,6 - 38,6 19,7 ± 6,9 12,8 - 26,6

MID% % 5,7 ± 4,2 1,5 - 9,9 6,5 ± 5,2 1,3 - 11,7 4,2 ± 3,3 0,9 - 7,5

GRAN% % 40,0 ± 14,0 26,0 - 54,0 64,9 ± 13,0 51,9 - 77,9 76,1 ± 11,4 64,7 - 87,5

DIAGON Ltd.
48-52., Baross Str.
Budapest, Hungary
H-1047

You might also like