Bogart Engineering
www.bogartengineering.com
07/31/2017
How to use the TM-2030 to control two SC-2030 Solar chargers to control up to
62 amps from solar panels in a 12 or 24V battery system.
You can't just parallel the solar inputs of the SC-2030 and connect 60 amps from panels, because the current won't properly
divide between the two. Therefore when using two SC-2030’s, the solar panels should be separated into two roughly equal
groups, with a separate pair of wires for each group going to the inputs of two separate SC-2030's. However the outputs from
each SC-2030 to the batteries can be paralleled in the obvious way: + to + and minus to minus .This is illustrated on the next
page.
The two SC-2030 Solar Chargers are slightly different: one will be identified as Unit 1 and the other Unit 2. They will be
distinguished because Unit 2 has an identifying jumper (see kit below) that needs to be plugged into connector J6 on the rear
of the unit. The temperature sensor should be connected to the SC-2030 Unit 1, without the jumper. Temperature
information from the Unit 2 SC-2030 will be ignored.
When these are wired as shown on the wiring diagram on page 2, you will be able to see solar
current (SOL) separately from each SC-2030. To access the SOL display, the SC-2030 must be
properly connected to the Trimetric, and solar current must be available to the panels.
Press and hold select until you see AH appear in the display, then repeatedly press select to access
SOL. This should appear after “rPC”. The SOL display will show the solar current from unit 1. Press
reset to show solar current from unit 2 (S02).
The “crossed” and “non-crossed” cables are distinguished by the way the two connectors are
attached at each end as shown in the diagram below. Polarity of the connectors must be carefully
observed.
As shown on wiring diagram, three communication cables from TM2030 to SC2030’s are required. Two of the two cables
need to be “non crossed” as described below, and are usually short. One of these is connected to each of the SC-2030's,
with the other end connected to the 3 way modular triplex adapter--thus occupying two of the three positions on the adapter.
A kit is available that contains two 3.5 ft straight cables, one triplex phone adapter, and one
identifying jumper referred to above. The third longer cable must be crossed as shown
below. This goes from the TM-2030 to the phone adapter. Verify polarity if purchasing from
another store or retailer.
Make or purchase one (usually longer) Crossed Make two (usually shorter) Non-crossed
phone cable from TM-2030 to 3 way phone adapter phone cables.
connector.
yellow yellow yellow black
not necessarily the
green green colors shown here green red
red red red green
black black black yellow
Hold two RJ-14 connectors Hold two RJ-14 connectors
from each end together of 4 from each end together of 4
wire phone cable. wire phone cable.
These views show facing the sides of the connectors that do not have the plastic retainer
clip. Commercially modular cables used to usually be made "crossed", but recently
there seems to be no consistency to the way they are made.
Each SC-2030 can deliver up to 31 Amps to batteries. If current exceeds 31
amps, this will not damage the SC-2030 but the battery current will then be
limited to less than 31A to protect the charger and the yellow light will flash.
One unit must be distinguished by inserting a “unit 2” identifying jumper on
connector J6 on rear of SC-2030. Temperature sensor should be placed
on unit 1.
Set 1 of solar
panels. Solar Set 2 of solar
Unit 1 current shown on Unit 2 panels. Solar
UP TM-2030 “SoL” SC-2030
UP
current shown
SC-2030 display.
Overcurrent if flashing
on TM-2030
Overcurrent if flashing
Solar DOWN Temperature also Solar DOWN “So2” display.
displayed. Charger(2)
Battery Type: AGM -down. FLOOD -up
Charger Battery Type: AGM -down. FLOOD -up
System volts:12V-down. 24V-up.
System volts:12V-down. 24V-up.
For 12V or For 12V or
24V systems 24V
only systems
only
Connected
Connected
TM-2030
TM-2030
BATTERY SOLAR BATTERY SOLAR
NON CROSSED
communication phone cables
3 plug phone
adapter. 3 Male end
female not used.
connections
shunt
To Battery
Temp Bank
sensor
Back of
Connect
temperature TriMetric TM-2030
sensor to battery monitor
Unit 1.
Wiring for two
CROSSED
SC-2030 with communication
G1 G2 SIG B1 B2
one TM-2030 phone cable
4 (or 5) wires to shunt and battery.