Cable Gland Type
15.0mm 'G' Approx (Compressed Length)
Metric Deluge Diaphragm Armour/Braid
Entry Boot Seal 'C'
501/453/Universal
ATEX
Entry Thread
Ø 'A'
Ø 'B'
Flameproof and Increased Safety
Application
CABLE GLAND SELECTION TABLE Outdoor or Indoor use.
501/453/Universal Cable Gland
Cable Acceptance Details For use with single wire
Entry Thread Hexagon
Size 'C' Dimensions armoured 'W', wire braided 'X'
Size Inner Sheath Outer Sheath
Armour/Braid 'G' and steel tape armoured 'Z',
Ref. NPT* 'A' 'B'
Across Across elastomer and plastic insulated
Metric Std./ Orientation Orientation cables.
Option Min. Max. Min. Max. 1 2
Flats Corners
For particular use with :-
Os M20 2 ½" 3.0 8.1 5.5 12.0 0.8/1.25 0/0.8 64.4 24.0 27.7 Cables that exhibit
2
O M20 ½" 6.5 11.9 9.5 16.0 0.8/1.25 0/0.8 64.4 24.0 27.7 "Cold Flow" characteristics.
A M20 ¾"/½" 8.4 14.3 12.5 20.5 0.8/1.25 0/0.8 65.4 30.0 34.6 See technical section of
B M25 1"/¾" 11.1 20.2 16.9 26.0 1.25/1.6 0/0.7 71 36.0 41.6 catalogue for installation rules
17.6 26.5 0/0.7 46.0 53.1 and regulations.
C M32 1¼"/1" 22.0 33.0 1.6/2.0 76
Features
C2 M40 1½"/1¼" 23.1 32.5 28.0 41.0 1.6/2.0 0/0.7 78.1 55.0 63.5
Provides armour clamping using
D M50 2"/1½" 28.9 44.4/42.31 36.0 52.6 1.8/2.5 0/1.0 93.1 65.0 75.1 one clamping arrangement for
E M63 2½"/2" 39.9 56.3/54.31 46.0 65.3 1.8/2.5 0/1.0 99 80.0 92.4 all armour/braid types.
F M75 3"/2½" 50.5 68.2/65.31 57.0 78.0 1.8/2.5 0/1.0 101.9 95.0 109.6 Provides a diaphragm seal on
Larger cable glands available in 501/453 design with a compression type inner seal. the cables inner sheath which
will not damage cable that has
G M80 3½" 67.0 73.0 75.0 89.5 # # 90.6 106.4 123.0
"Cold Flow" characteristics.
H M90 3½" 67.0 77.6 75.0 89.5 # # 90.6 115.0 132.8 Provides an outer deluge seal
J M100 4" 75.0 91.6 88.0 104.5 # # 90.6 127.0 146.7 to prevent moisture ingress to
1 Smaller value is applicable when selecting reduced NPT entry option. the cable armour/braid.
2 Sizes Os and O are available with an M16 thread size. For O size with M16 thread,
Provides a cable retention and
the maximum cable inner sheath diameter is 10.9mm. low smoke and fume, zero halogen
# Dedicated armour clamping rings are fitted. Please specify armour type and size when ordering.
seal onto the cables outer sheath.
General Information Alternative Reversible Armour Technical Data
Os - F size metric entry threads are 1.5mm Clamping Rings (RAC)
Flameproof Exd and Increased
pitch as standard. Safety Exe II 2 GD
For G size glands and above, a 2mm pitch is SELECTION TABLE
Steel Wire Armour/Braid/Tape
Baseefa 06ATEX0057X for sizes Os to F.
Size
supplied as standard. Ref. IECEx BAS06.0014X for sizes Os to F.
Orientation 1 Orientation 2
(1.5mm pitch with 15mm length of thread can B 0.9 - 1.25 0.5 - 0.9 Baseefa 06ATEX0056X for sizes G to J.
be supplied) please specify when ordering. C 1.2 - 1.6 0.6 - 1.2 IECEx BAS06.0013X for sizes G to J.
Thread length is 15mm for sizes Os to F and C2 1.2 - 1.6 0.6 - 1.2
Suitable for use in Zone 1,
D 1.45 - 1.8 1.0 - 1.45
20mm for sizes G to J. 1.0 - 1.45 Zone 2, Zone 21 and Zone 22.
E 1.45 - 1.8
All dimensions in millimetres F 1.45 - 1.8 1.0 - 1.45 Suitable for use in Gas Groups IIA, IIBand IIC.
(except* where dimensions are in inches). Construction and test standards
Assembly instruction data sheet No. A.I. 300 EN 50014, EN 50018, EN 50019
for sizes Os to F. and EN 50281-1-1. IEC 60079-0,
Assembly instruction data sheet No. A.I. 303 IEC 60079-1, IEC 60079-7 and IEC 61241-1.
for sizes G to J. IP66, IP67 and IP68 (30 metres for 7 days)
ingress protection to IEC 60529,
Accessories including locknuts, sealing washers, serrated washers, earth tags, shrouds, EN 60529 and NEMA 4X.
adaptors and reducers available. See pages 53 - 57. DTS01 deluge protection certified by ITS.
Operating temperature range
-60°C to +80°C as standard.
Materials & Finishes Alternative Certification Options Available.
The 501/453/Universal cable gland is manufactured in brass (standard), nickel plated brass, Exd IIC/Exe II.
316 stainless steel or aluminium.
BR-Exd IIC/Exe II.
Brass NPT entries are nickel plated as standard.
GOST R-Exd IICU/Exe IIU.
Cable Gland Ordering Examples Approved for use in Kazakhstan.
Cable Gland Type/Size/Thread Cable Gland with Alternative
Clamping Ring (AR) Exd IIC/Exe II/DIP A21 IP66.
e.g. 501/453/UNIV/C/M32 Marine Approval.
501/453/UNIV/C/1¼" NPT e.g. 501/453/UNIV/C/M32/AR
501/453/UNIV/C/1¼" NPT/AR
Marine Approval.
WWW.CABLEJOINTS.CO.UK
Connection Solutions
THORNE & DERRICK UK International
www.ehawke.com
TEL 0044 191 490 1547 FAX 0044 477 5371
HWK74 Feb '08
TEL 0044 117 977 4647 FAX 0044 977 5582
WWW.THORNEANDDERRICK.CO.UK