0% found this document useful (0 votes)
222 views1 page

501/453/universal Cable Gland Type: Flameproof and Increased Safety

The document is a selection table for cable gland types that provides the specifications for different sizes including entry thread size, cable acceptance details, dimensions, material options, and certifications. It includes information on the metric entry threads, dimensions in millimeters, flameproof and increased safety approvals, operating temperature range, and ingress protection ratings. Accessories are available.

Uploaded by

mahdimazini
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
222 views1 page

501/453/universal Cable Gland Type: Flameproof and Increased Safety

The document is a selection table for cable gland types that provides the specifications for different sizes including entry thread size, cable acceptance details, dimensions, material options, and certifications. It includes information on the metric entry threads, dimensions in millimeters, flameproof and increased safety approvals, operating temperature range, and ingress protection ratings. Accessories are available.

Uploaded by

mahdimazini
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Cable Gland Type

15.0mm 'G' Approx (Compressed Length)

Metric Deluge Diaphragm Armour/Braid


Entry Boot Seal 'C'

501/453/Universal
ATEX
Entry Thread

Ø 'A'

Ø 'B'
Flameproof and Increased Safety

Application
CABLE GLAND SELECTION TABLE Outdoor or Indoor use.

501/453/Universal Cable Gland


Cable Acceptance Details For use with single wire
Entry Thread Hexagon
Size 'C' Dimensions armoured 'W', wire braided 'X'
Size Inner Sheath Outer Sheath
Armour/Braid 'G' and steel tape armoured 'Z',
Ref. NPT* 'A' 'B'
Across Across elastomer and plastic insulated
Metric Std./ Orientation Orientation cables.
Option Min. Max. Min. Max. 1 2
Flats Corners
For particular use with :-
Os M20 2 ½" 3.0 8.1 5.5 12.0 0.8/1.25 0/0.8 64.4 24.0 27.7 Cables that exhibit
2
O M20 ½" 6.5 11.9 9.5 16.0 0.8/1.25 0/0.8 64.4 24.0 27.7 "Cold Flow" characteristics.
A M20 ¾"/½" 8.4 14.3 12.5 20.5 0.8/1.25 0/0.8 65.4 30.0 34.6 See technical section of
B M25 1"/¾" 11.1 20.2 16.9 26.0 1.25/1.6 0/0.7 71 36.0 41.6 catalogue for installation rules
17.6 26.5 0/0.7 46.0 53.1 and regulations.
C M32 1¼"/1" 22.0 33.0 1.6/2.0 76
Features
C2 M40 1½"/1¼" 23.1 32.5 28.0 41.0 1.6/2.0 0/0.7 78.1 55.0 63.5
Provides armour clamping using
D M50 2"/1½" 28.9 44.4/42.31 36.0 52.6 1.8/2.5 0/1.0 93.1 65.0 75.1 one clamping arrangement for
E M63 2½"/2" 39.9 56.3/54.31 46.0 65.3 1.8/2.5 0/1.0 99 80.0 92.4 all armour/braid types.
F M75 3"/2½" 50.5 68.2/65.31 57.0 78.0 1.8/2.5 0/1.0 101.9 95.0 109.6 Provides a diaphragm seal on
Larger cable glands available in 501/453 design with a compression type inner seal. the cables inner sheath which
will not damage cable that has
G M80 3½" 67.0 73.0 75.0 89.5 # # 90.6 106.4 123.0
"Cold Flow" characteristics.
H M90 3½" 67.0 77.6 75.0 89.5 # # 90.6 115.0 132.8 Provides an outer deluge seal
J M100 4" 75.0 91.6 88.0 104.5 # # 90.6 127.0 146.7 to prevent moisture ingress to
1 Smaller value is applicable when selecting reduced NPT entry option. the cable armour/braid.
2 Sizes Os and O are available with an M16 thread size. For O size with M16 thread,
Provides a cable retention and
the maximum cable inner sheath diameter is 10.9mm. low smoke and fume, zero halogen
# Dedicated armour clamping rings are fitted. Please specify armour type and size when ordering.
seal onto the cables outer sheath.
General Information Alternative Reversible Armour Technical Data
Os - F size metric entry threads are 1.5mm Clamping Rings (RAC)
Flameproof Exd and Increased
pitch as standard. Safety Exe II 2 GD
For G size glands and above, a 2mm pitch is SELECTION TABLE
Steel Wire Armour/Braid/Tape
Baseefa 06ATEX0057X for sizes Os to F.
Size
supplied as standard. Ref. IECEx BAS06.0014X for sizes Os to F.
Orientation 1 Orientation 2
(1.5mm pitch with 15mm length of thread can B 0.9 - 1.25 0.5 - 0.9 Baseefa 06ATEX0056X for sizes G to J.
be supplied) please specify when ordering. C 1.2 - 1.6 0.6 - 1.2 IECEx BAS06.0013X for sizes G to J.
Thread length is 15mm for sizes Os to F and C2 1.2 - 1.6 0.6 - 1.2
Suitable for use in Zone 1,
D 1.45 - 1.8 1.0 - 1.45
20mm for sizes G to J. 1.0 - 1.45 Zone 2, Zone 21 and Zone 22.
E 1.45 - 1.8
All dimensions in millimetres F 1.45 - 1.8 1.0 - 1.45 Suitable for use in Gas Groups IIA, IIBand IIC.
(except* where dimensions are in inches). Construction and test standards
Assembly instruction data sheet No. A.I. 300 EN 50014, EN 50018, EN 50019
for sizes Os to F. and EN 50281-1-1. IEC 60079-0,
Assembly instruction data sheet No. A.I. 303 IEC 60079-1, IEC 60079-7 and IEC 61241-1.
for sizes G to J. IP66, IP67 and IP68 (30 metres for 7 days)
ingress protection to IEC 60529,
Accessories including locknuts, sealing washers, serrated washers, earth tags, shrouds, EN 60529 and NEMA 4X.
adaptors and reducers available. See pages 53 - 57. DTS01 deluge protection certified by ITS.
Operating temperature range
-60°C to +80°C as standard.
Materials & Finishes Alternative Certification Options Available.
The 501/453/Universal cable gland is manufactured in brass (standard), nickel plated brass, Exd IIC/Exe II.
316 stainless steel or aluminium.
BR-Exd IIC/Exe II.
Brass NPT entries are nickel plated as standard.
GOST R-Exd IICU/Exe IIU.
Cable Gland Ordering Examples Approved for use in Kazakhstan.
Cable Gland Type/Size/Thread Cable Gland with Alternative
Clamping Ring (AR) Exd IIC/Exe II/DIP A21 IP66.
e.g. 501/453/UNIV/C/M32 Marine Approval.
501/453/UNIV/C/1¼" NPT e.g. 501/453/UNIV/C/M32/AR
501/453/UNIV/C/1¼" NPT/AR
Marine Approval.

WWW.CABLEJOINTS.CO.UK
Connection Solutions
THORNE & DERRICK UK International
www.ehawke.com
TEL 0044 191 490 1547 FAX 0044 477 5371
HWK74 Feb '08
TEL 0044 117 977 4647 FAX 0044 977 5582