Daikin Air Conditioning Solutions Overview
Daikin Air Conditioning Solutions Overview
Prior to
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this
product conforms to the applicable standards, and is suitable for use, in the region where the product PLXSID1605
will be used. This statement does not purport to exclude, restrict or modify the application of any local
legislation.
Use only those parts and accessories supplied or specified by Daikin.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of June 2016 but subject to change without notice. c All rights reserved
The solution for light commercial sector
Providing the ideal solution for all kinds of small commercial space such as shops, restaurant and
small offices. The Sky Air series offers a complete comfort solution that puts you in total control.
Product Lineup
PK 2.0 2.5 3.0 3.0 3.5 4 5
Capacity Btu/h 18500 23000 28000 28000/29000* 36000 42000 55000
kW 5.4 6.7 8.2 8.2/8.5* 10.5 12.3 16.1
Ceiling Cassette
Type
Floor Standing
Type
Outdoor Unit
01 02
4-way air flow Compact body and quiet operation
Ceiling Cassette This unit promotes even air distribution covering every
corner of the room by combining 4-ways air discharge
and large discharge area.
Indoor units as an aerodynamically designed Difuser
Turbo Fan.
Type
4 way air flow ceiling cassette
FCRN50/60/71/100/125FXV14
Draft resistance has been reduced by incorporating into
Fine square panels a single unit, an impeller and a diffuser to control air flow
Panel size is same for all models. It is easy to maintain a inside the unit. The Diffuser Turbo Fan is both quiet
neat appearance when multiple units are installed. during operation and compact.
Low Quiet
Indoor Unit dB(A) dB(A)
FCRN50F 33 29
FCRN60F 34 31
950mm
FCRN71F 35 32
FCRN100F 37 34
FCRN125F 41 37
950mm
1 2 3
Air direction in Air direction in draft Air direction in ceiling
standard setting prevention setting soiling prevention setting
For gentle drafts. Select this setting to eliminate Recommended for location
direct drafts which can lead to with light colour ceiling that
discomfort. must be kept spotless.
The default setting for air swing pattern is 1. The air swing pattern can be selected through the wireless remote control.
Network Interface Module (NIM)
Two selectable temperature
Group control by
Self diagnosis
Swing pattern
Auto swing
sensor
Both indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be
set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature
must be set during commissioning by the technicians.
* Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
*1 *1
03 04
Switchable fan speed: Indoor unit ON/OFF switch Drain pump is equipped as standard accessory with 700mm lift
The unit can be conveniently started manually in the This unit comes with a condensate water drain pump which can pump water up to 700mm higher from drain pipe
High ➡ Medium ➡ Low ➡ Quiet event the wireless remote controller is misplaced or the outlet. Safety float is incorporated to monitor water level.
wireless remote controller batteries are not charged.
High setting provides maximum reach while low setting
minimises drafts.
Extra protection
Timer selector This unit covered with insulation material acts as extra
protection when installed under very high humidity 700mm
Operation starts when the preset time of the ON timer
environment to prevent condensation.
elapses and stops when the preset time of the OFF
timer elapses.
Powerful operation
New powerful operation boosts airflow to maximum
volume for a 20-minute period with highest fan
speed. After this, the unit automatically returns to its
previous settings.
Easy Maintenance
Easy Installation
Drain plug
*246mm Simple step to change fan motor
• Without removing panel, it can be
easily access and service to
* 246mm high with FCRN50/60/71
fan motor
* 288mm high with FCRN100/125
• Reduced troubleshooting and Self-diagnosis function
servicing time This intelligent feature helps to detect faults or
All models can be installed without using lifter because • Three simple steps: malfunctioning in the system and give user a warning by
of the light weight.
Control box ➡ Fan cover ➡ Blower fan ➡ Fan motor blinking of the LED light or display error code on wired
controller.
Detachable corner
For the ease and flexibility of installation, this unit is Position of connecting pipe and drain hose
designed with 4 detachable corners where installer is In order to create more space for installer to work on Options required for specific operating environments
able to fit their hand in to adjust hanging hook and connection pipe of indoor unit, the connection pipe of
perform drain leakage check. gas and liquid are located further from each other and
purposely not align to hanging hook. Fresh air intake kit
To enhance the convenience of installation, drain hose Using this kit*, a duct can be fitted to increase the intake
location is relocated to another side of cassette unit (not of outdoor air.
same side with connection pipe)
Knock-out hole
Easy accessible control box The built-in knock-out hole are available for fresh air
Control box of this unit can be accessed directly from intake or branch duct.
the intake grille for ease of installation and servicing
process.
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.
05 06
Floor Standing Auto-swing mode
This unit uses its automatic horizontal swing louver to spread
comfortable air flow to cool every corner of the room. Its
Timer selector
Operation starts when the preset time of the ON timer
elapses and stops when the preset time of the OFF
Powerful operation
The floor standing is designed to look sleek, stylish and modern to New powerful operation boosts airflow to maximum
blend into any environment. Its slim profile promotes an ideal way volume for a 20-minute period with highest fan
of space saving with style and functionality. Its high gloss speed. After this, the unit automatically returns to its
finishing makes it easy for cleaning. With its ease of installation, it previous settings.
is suited to be installed in offices, commercial shops, restaurants,
showrooms and mosque. Indoor unit ON/OFF switch
The unit can be conveniently started manually in the
event the wireless remote controller is misplaced or the
FVRN71/100/125/140FXV14 wireless remote controller batteries are not charged.
Manual setting of
Auto horizontal swing
vertical airflow louvers
1.22
controls.
0.00
* Temperature-sensor on indoor unit must be used when the air conditioner is controlled
Washable saranet filter
Switchable fan speed
Group control by
Timer selector
Self diagnosis
Auto swing
07 08
Outdoor Unit Controllers
Wireless controller BRC52A
Fitted with wide inlet fan Equipped with scroll compressor for
Fully shaped aerodynamic propellers are designed to quiet operation
push air with a large wing surface, providing both high Wired controller BRC51A
blow volume and quiet operation with turbulence. Smooth running, minimal vibration, low operating sound.
* Only applicable to RR100/125/140DXY1A4
1
Durability
• The unit is covered with corrosion-proof galvanized steel to enhance its durability.
• Heat exchange fins are provided with anti-corrosion treatment.
09 10
Simple system that provides flexibility of controls Sequential control by Sequential Network Interface Module (S-NIM)
Control two units of air conditioner in a master and slave system, operating at alternate sequence of preset hours
Control Pattern Remote Controls
(3/4/5/7/9/11/12 hours), controlled by a single BRC51A controller.
The S-NIM controls consist of:
• Mainboard
• Control panel (BRC51A)
Group control by Network For simultaneous control of • S-NIM controller
Interface module (NIM) up to 16 indoor units NIM NIM NIM NIM • Communication bus
The S-NIM is suitable in environment requiring 24-hours air conditioning, such as server room, room containing critical
electronics equipment, laboratories, telecommunication towers, railway switching centre and 24-hours shoplets. It also
extends the operating lifetime of existing air conditioning units.
Preset Switching
Sequential control by For sequential control of Time: 3 hours
After 3 hours
ON OFF OFF ON
• Mainboard
• Control panel (BRC51A) Control by external command using G-way
• NIM controller
• Communication bus
The G-way controls consist of:
NIM utilizes master-slave configurations. One master can control up to 15 slave
units in a group. The master unit operates in conjunction with a control panel. Any • Mainboard
settings done via the control panel connected to the master overwrite the settings • Control panel (BRC51A)
of its slave units. Slave units can be operated with or without control panel. If a • G-way controller
slave unit is operating with a control panel, its settings can be changed without • Communication bus
following its master’s.
It is a gateway between the air conditioning unit and basic Building
• DIP switch setting for group and unit address Management System (BMS). G-way controller enables:
• Automatic detection of control panel
• Error codes and error unit’s ID indication on control panel • Remote (ON/OFF) of air conditioner via BMS.
• Supported configurations of NIM: • Unit error indication via BMS and BRC51A controller.
• Unit operation status monitoring via BMS.
Master Slave
• DIP switch setting for control or monitoring function.
BRC51A • Maximum point-to-point distance of 1000m.
NIM controller BRC52A G-way controller
11 12
Control by external command using BMS Access Gateway (BAG) Abundance of functions that provide comfortable air-conditioning in stores and offices
BAG interfaces the air conditioner unit to BMS system via input contacts,
resistance inputs and dry contacts outputs which allows the monitoring
Comfort
and controls of the air conditioner. The BAG enables:
Auto-swing Two selectable temperature-sensors
• Controls of the air conditioner unit’s ON/OFF status, operating mode, Delivers comfortable air-conditioning to all areas, near Temperature-sensors are included in the indoor unit
fan speed setting, room temperature setting as well as forcing off the unit in to and far from the air-conditioner. and optional wired remote controller. temperature
the event of fire. sensing closer to target area is possible to further
• Indication to warn the control room in the event of air conditioner failure. increase the comfort level.
• Maximum point-to-point distance of 1100m (please refer to the Swing pattern selection
You can freely set 3 air discharge setting by remote controller. Use the temperature-sensor in the indoor unit when
installation manual)
controlling air conditioning from another room.
Individual air conditioners can be turned on from the control room’s Input Contact
Switchable fan speed (*available on all models) Timer selector
connection Selectable High, Medium and Low fan speed. High Operation starts when the preset time of the ON
setting provides maximum reach while low setting timer elapse and stops when the preset time of the
minimizes drafts. OFF timer elapses.
Cleanliness
Washable saranet filter
Removal of air-borne dust particles through saranet filter ensures cleaner air supply.
BAG
BAG
BAG
Work and Servicing
BAG
Comparison between G-way controls and BAG controls Drain pump mechanism
Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.
Features G-way BAG
Force Off
ON/OFF
Pre-charge for up to 7.5 metres
Input Contacts Operating Mode
If refrigerant piping length does not exceed 7.5m, there is no need for on-site gas charging. However for any piping
Fan Speed
length more than 7.5m, requires for additional charge.
(Applies for all models)
Set Temperature
ON/OFF Status
Dry Contact
Outputs
Operating Mode Self diagnosis function (*available on all models)
Fault Status
The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the
Note: system, are constantly monitored using a microcomputer. This intelligent feature helps to detect faults or
Communication Bus malfunctioning in the system and give user a warning by blinking of the LED light on the unit or display error code
A 2-way twisted pair cable is used as the communication bus. Recommended cable for communication bus is a pair of screened & shielded, wisted single core wire with on the wired controller.
core diameter of 0.5mm to 1.0mm.
13 14
Auto random restart (*available on all models)
Control features
Specifications
If there is a power outage while the equipment is operating, operations will restart randomly (within 180 to 244
seconds) in the same mode as before the power cut when electricity is restored.
Ceiling cassette
Group control by Network Interface Module (NIM) Capacity PK 2.0 2.5 3.0 3.0 3.5 4.0
You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the Indoor unit FCRN50FXV14 FCRN60FXV14 FCRN71FXV14 FCRN71FXV14 FCRN100FXV14 FCRN125FXV14
settings must all be the same and on/off will be simultaneous.) Model Outdoor unit RN50CXV1A4 RN60CXV1A4 RR71CXV1A4 RR71CXY1A4 RR100DXY1A4 RR125DXY1A4
Power supply V/Ph/Hz 220-240/1/50 (power from outdoor) 380-415/3/50 (power from outdoor)
Options
Airflow (H/M/L/Q) cfm 730/620/510/360 840/700/560/440 890/760/620/490 890/760/620/491 1030/870/730/580 1120/1030/890/760
Sound pressure level (H/M/L/Q) dB(A) 38/35/33/29 39/37/34/31 41/38/35/32 41/38/35/33 46/41/37/34 48/45/41/37
Indoor unit
Unit mm 246x840x840 246x840x840 246x840x840 246x840x841 288x840x840 288x840x840
You can provide air-conditioning with fresh air from outside. Unit kg 22 22 22 22 25 25
It is convenient for places where a ventilation fan cannot be installed. Machine weight
decoration panel kg 5 5 5 5 5 5
Outdoor unit
Machine weight kg 43 47 57 56 71 95
1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length: 7.5m
Floor standing
Capacity PK 3.0 3.0 3.5 4.0 5.0
220-240/1/50 380-415/3/50
Power supply V/Ph/Hz
(power from outdoor) (power from outdoor)
Indoor unit
Sound pressure level (H/M/L) dB(A) 44/42/39 44/42/39 49/47/44 49/47/44 54/53/51
Machine weight kg 42 42 45 45 51
1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length: 7.5m
15 16
Note:
17