100% found this document useful (1 vote)
273 views10 pages

Daikin Air Conditioning Solutions Overview

This document provides warnings and instructions for Daikin products manufactured for export. It states that before purchasing, users should confirm that the product complies with applicable standards in their region. It also instructs users to only use approved parts and accessories, and to carefully read the user manual for important safety information and warnings. Contact local importers, distributors or retailers for any inquiries.

Uploaded by

Ben Firdaus
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
273 views10 pages

Daikin Air Conditioning Solutions Overview

This document provides warnings and instructions for Daikin products manufactured for export. It states that before purchasing, users should confirm that the product complies with applicable standards in their region. It also instructs users to only use approved parts and accessories, and to carefully read the user manual for important safety information and warnings. Contact local importers, distributors or retailers for any inquiries.

Uploaded by

Ben Firdaus
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Warning Daikin products are manufactured for export to numerous countries throughout the world.

Prior to
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this
product conforms to the applicable standards, and is suitable for use, in the region where the product PLXSID1605
will be used. This statement does not purport to exclude, restrict or modify the application of any local
legislation.
Use only those parts and accessories supplied or specified by Daikin.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Dealer PT. DAIKIN AIRCONDITIONING INDONESIA


Head Office:
Wisma KEIAI, 18th Floor
JI. Jendral Sudiman Kav 3, Jakarta Pusat 10220
Telp : +6221-572 4377
Fax : +6221-572 4366/55
Website : http://www.daikin.co.id
Service and Spare Parts, Telp.: 021-736 92899 • Training Center, Telp.: 021-295 61950 • Bandung,
Telp.: 022-601 4781 • Semarang, Telp: 012-841 2695 • Surabaya, Telp.: 031-503 1138 • Denpasar,
Telp.: 0361-900 5514 • Makassar, Telp.: 0411-446 263 • Palembang, Telp.: 0711-319 776
Daikin Contact Center: 0800 1 081 081 (Toll Free)

Specifications, designs and other content appearing in this brochure are current as of June 2016 but subject to change without notice. c All rights reserved
The solution for light commercial sector
Providing the ideal solution for all kinds of small commercial space such as shops, restaurant and
small offices. The Sky Air series offers a complete comfort solution that puts you in total control.

Product Lineup
PK 2.0 2.5 3.0 3.0 3.5 4 5
Capacity Btu/h 18500 23000 28000 28000/29000* 36000 42000 55000
kW 5.4 6.7 8.2 8.2/8.5* 10.5 12.3 16.1

Ceiling Cassette
Type

Indoor unit FCRN50FXV14 FCRN60FXV14 FCRN71FXV14 FCRN71FXV14 FCRN100FXV14 FCRN125FXV14


Outdoor unit RN50CXV1A4 RN60CXV1A4 RR71CXV1A4 RR71CXY1A4 RR100DXY1A4 RR125DXY1A4

Floor Standing
Type

Indoor unit FVRN71BXV14 FVRN71BXV14 FVRN100BXV14 FVRN125BXV14 FVRN140BXV14


Outdoor unit RR71CXV1A4 RR71CXY1A4 RR100DXY1A4 RR125DXY1A4 RR140DXY1A4

Outdoor Unit

RN50CXV1A4 RN60CXV1A4 RR71CXV1A4 RR71CXY1A4 RR100DXY1A4 RR125DXY1A4 RR140DXY1A4

*Only applicable for Floor Standing Type

01 02
4-way air flow Compact body and quiet operation
Ceiling Cassette This unit promotes even air distribution covering every
corner of the room by combining 4-ways air discharge
and large discharge area.
Indoor units as an aerodynamically designed Difuser
Turbo Fan.

Type
4 way air flow ceiling cassette

FCRN50/60/71/100/125FXV14
Draft resistance has been reduced by incorporating into
Fine square panels a single unit, an impeller and a diffuser to control air flow
Panel size is same for all models. It is easy to maintain a inside the unit. The Diffuser Turbo Fan is both quiet
neat appearance when multiple units are installed. during operation and compact.

Low Quiet
Indoor Unit dB(A) dB(A)
FCRN50F 33 29

FCRN60F 34 31
950mm
FCRN71F 35 32

FCRN100F 37 34

FCRN125F 41 37
950mm

Wired Controller: Wireless Controller:


BRC51A BRC52A
* Optional * Supplied with panel Optimal comfort and convenience assured by air discharge modes
To increase the comfort level of the air conditioned area, the system is built-in with 3 different types of air flow pattern
to suit different requirements.

1 2 3
Air direction in Air direction in draft Air direction in ceiling
standard setting prevention setting soiling prevention setting
For gentle drafts. Select this setting to eliminate Recommended for location
direct drafts which can lead to with light colour ceiling that
discomfort. must be kept spotless.

COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES OPTIONS

The default setting for air swing pattern is 1. The air swing pattern can be selected through the wireless remote control.
Network Interface Module (NIM)
Two selectable temperature

Pre-charged for up to 7.5m

External command control


Weekly scheduled timer

Drain pump mechanism


Washable saranet filter
Switchable fan speed

using G-way or BAG


Auto random restart

Fresh-air intake kit


Programme “Dry”

Group control by

Two selectable temperature sensors


Timer selector

Self diagnosis
Swing pattern
Auto swing

sensor

Both indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be
set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature
must be set during commissioning by the technicians.
* Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
*1 *1

*1 Applicable when wired controller is used.

03 04
Switchable fan speed: Indoor unit ON/OFF switch Drain pump is equipped as standard accessory with 700mm lift
The unit can be conveniently started manually in the This unit comes with a condensate water drain pump which can pump water up to 700mm higher from drain pipe
High ➡ Medium ➡ Low ➡ Quiet event the wireless remote controller is misplaced or the outlet. Safety float is incorporated to monitor water level.
wireless remote controller batteries are not charged.
High setting provides maximum reach while low setting
minimises drafts.
Extra protection
Timer selector This unit covered with insulation material acts as extra
protection when installed under very high humidity 700mm
Operation starts when the preset time of the ON timer
environment to prevent condensation.
elapses and stops when the preset time of the OFF
timer elapses.

Powerful operation
New powerful operation boosts airflow to maximum
volume for a 20-minute period with highest fan
speed. After this, the unit automatically returns to its
previous settings.

Easy Maintenance
Easy Installation

Quick and easy to install Panel-hook mechanism Easier to maintain


The condition of the drain pan and drain water can be Just open the
Just 246mm high. Installable in tight ceiling spaces. This feature enables the installer to work with both
checked by removing the drain plug and intake grille. intake grille!
hands as the panel can be hung on the unit.

Drain plug
*246mm Simple step to change fan motor
• Without removing panel, it can be
easily access and service to
* 246mm high with FCRN50/60/71
fan motor
* 288mm high with FCRN100/125
• Reduced troubleshooting and Self-diagnosis function
servicing time This intelligent feature helps to detect faults or
All models can be installed without using lifter because • Three simple steps: malfunctioning in the system and give user a warning by
of the light weight.
Control box ➡ Fan cover ➡ Blower fan ➡ Fan motor blinking of the LED light or display error code on wired
controller.
Detachable corner
For the ease and flexibility of installation, this unit is Position of connecting pipe and drain hose
designed with 4 detachable corners where installer is In order to create more space for installer to work on Options required for specific operating environments
able to fit their hand in to adjust hanging hook and connection pipe of indoor unit, the connection pipe of
perform drain leakage check. gas and liquid are located further from each other and
purposely not align to hanging hook. Fresh air intake kit
To enhance the convenience of installation, drain hose Using this kit*, a duct can be fitted to increase the intake
location is relocated to another side of cassette unit (not of outdoor air.
same side with connection pipe)

Knock-out hole
Easy accessible control box The built-in knock-out hole are available for fresh air
Control box of this unit can be accessed directly from intake or branch duct.
the intake grille for ease of installation and servicing
process.
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.

05 06
Floor Standing Auto-swing mode
This unit uses its automatic horizontal swing louver to spread
comfortable air flow to cool every corner of the room. Its
Timer selector
Operation starts when the preset time of the ON timer
elapses and stops when the preset time of the OFF

Type vertical louvers are adjusted manually to match different


interior spaces and partition as well as to avoid direct airflow.
timer elapses.

Powerful operation
The floor standing is designed to look sleek, stylish and modern to New powerful operation boosts airflow to maximum
blend into any environment. Its slim profile promotes an ideal way volume for a 20-minute period with highest fan
of space saving with style and functionality. Its high gloss speed. After this, the unit automatically returns to its
finishing makes it easy for cleaning. With its ease of installation, it previous settings.
is suited to be installed in offices, commercial shops, restaurants,
showrooms and mosque. Indoor unit ON/OFF switch
The unit can be conveniently started manually in the
event the wireless remote controller is misplaced or the
FVRN71/100/125/140FXV14 wireless remote controller batteries are not charged.
Manual setting of
Auto horizontal swing
vertical airflow louvers

User-friendly controls Easy Maintenance


The unit comes with a stylish black control panel with white
LED light for clear display. It comes with a keylock function Safety clip
to prevent setting change from unauthorised personnel. The safety clip feature allows the users to remove the
washable saranet filter with ease during maintenance.
OFF State ON State At the same time, it also acts as a safety feature to
White display lights up to
indicate modes and temperature prevent the users from reaching into the electrical and
settings when switched on
mechanical components.

Keylock icon displayed


when activated

Keylock Function: Safety clip


Activation and deactivation of
keylock by pressing “SWING”
and “TURBO” together for
5 seconds

Wired Controller: Wireless Controller: Additionally, this unit is incorporated


BRC51A BRC52A Far air flow with infrared sensor for usage with
* Optional * Supplied with unit
The Daikin floor standing is able to achieve air flow distance as wireless controller (BRC52A62) Space for water drain pump
far as 25m* which is about the size of a basketball court. which comes with the unit as the There is a space in the unit below the fan that allows
standard package. Thus, it can also users to install an external condensate water pump.
be controlled using wireless * The condensate water drain pump is separately purchased and field installed.
controller for the flexibility in
V_r (m/s)
Global
2.44

1.22
controls.
0.00

25m Two selectable temperature sensors


Both indoor unit and wired remote controller (option)
* Note: Based on size 140

contain temperature-sensors. Temperature sensing can be


set at the unit or, to further improve comfort level, closer to
COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES the target area at the wired remote control. This feature
must be set during commissioning by the technicians.
Network Interface Module (NIM)
Two selectable temperature

Pre-charged for up to 7.5m

External command control


Weekly scheduled timer

* Temperature-sensor on indoor unit must be used when the air conditioner is controlled
Washable saranet filter
Switchable fan speed

using G-way or BAG


Auto random restart

from another room.


Programme “Dry”

Group control by
Timer selector

Self diagnosis
Auto swing

**Wireless remote controller does not have a temperature-sensor


sensor

Switchable fan speed:


High ➡ Medium ➡ Low
*1 *1 Piping Condensate
High setting provides maximum reach while low setting Floor Standing Unit
water
drain pump
*1 Applicable when wired controller is used.
minimizes drafts.

07 08
Outdoor Unit Controllers
Wireless controller BRC52A

1 “Glow-in-the-dark” ON/OFF switch 6 Vertical auto-swing


1 2 Fan speed selection: 7 Selectable mode: Cool, Dry, Fan
6
2 Low, Medium, High, Auto
7
8 Turbo function
8 3 Temperature setting: Up & down 9 Quiet function
3
RR100DXY1A4 9 4 Sleep mode function 10 On timer setting
RN50CXV1A4 RR71CXV1A4 4
RR125DXY1A4 5 Off timer setting
RN60CXV1A4 RR71CXY1A4 10 5 11 Real time clock
RR140DXY1A4
11

Fitted with wide inlet fan Equipped with scroll compressor for
Fully shaped aerodynamic propellers are designed to quiet operation
push air with a large wing surface, providing both high Wired controller BRC51A
blow volume and quiet operation with turbulence. Smooth running, minimal vibration, low operating sound.
* Only applicable to RR100/125/140DXY1A4
1

1 Real time clock and day display 7 Turbo function


2 2 Temperature operate in ˚C and ˚F 8 Cool, Dry, Fan mode
7 3 3 Swing function 9 Delay timer (1 or 2 hours)
RR71C RR71C 8
Outdoor RN50C RN60C 4 7-days programmable timer
(1PH) (3PH)
9
4 Quiet function 10
Sound Pressure Level dBA 52 52 56 56 10 5 5 Sleep function 11 Low, Medium, High, Auto fan speed
11 6 6 ON/OFF switch
Outdoor RR100D RR125D RR140D

Sound Pressure Level dBA 58 60 65


Wide inlet fan Wired controller BRC51A can directly be connected to the unit’s main board to start operating without extra setting or
modification. It also has a built-in temperature sensor that enables temperature sensing closer to target area for
improved comfort (no settings required to activate the handset temperature sensor).

Installation and Maintenance

Pre-charged for up to 7.5 metres


Pre-charged Max. Piping Max. Piping
Model Piping Length, m Length, m Elevation, m
RN50C 7.5 30 15
RN60C 7.5 30 15
RR71C(1PH) 7.5 45 25
RR71C(3PH) 7.5 45 25 IR receiver on wired handset
received the signal
RR100D 7.5 50 30
RR125D 7.5 50 30
RR140D 7.5 45 25
Signal sent from
wireless handset

Durability
• The unit is covered with corrosion-proof galvanized steel to enhance its durability.
• Heat exchange fins are provided with anti-corrosion treatment.

09 10
Simple system that provides flexibility of controls Sequential control by Sequential Network Interface Module (S-NIM)
Control two units of air conditioner in a master and slave system, operating at alternate sequence of preset hours
Control Pattern Remote Controls
(3/4/5/7/9/11/12 hours), controlled by a single BRC51A controller.
The S-NIM controls consist of:

• Mainboard
• Control panel (BRC51A)
Group control by Network For simultaneous control of • S-NIM controller
Interface module (NIM) up to 16 indoor units NIM NIM NIM NIM • Communication bus

The S-NIM is suitable in environment requiring 24-hours air conditioning, such as server room, room containing critical
electronics equipment, laboratories, telecommunication towers, railway switching centre and 24-hours shoplets. It also
extends the operating lifetime of existing air conditioning units.

Preset Switching
Sequential control by For sequential control of Time: 3 hours
After 3 hours

Sequential Network Interface 2 indoor units at alternate


Module (S-NIM) sequence of pre-set hour S-NIM S-NIM
S-NIM S-NIM S-NIM S-NIM

ON OFF OFF ON

Operation and surveillance


Control by external command is carried out using the contact
using G-way or BAG signal from the operation
G-way/ G-way/ G-way/
control box in the building BAG BAG BAG
surveillance (security) room.
BMS
When the operating unit is faulty, the standby unit automatically takes over. Other features of S-NIM:

• Auto restart feature with last state settings.


Group control by Network Interface Module (NIM) • Error indication via error code display on the control panel.
• Pre-set operation hours via DIP switch.
• Maximum point to point distance of 1000m.
The NIM group controls consist of:

• Mainboard
• Control panel (BRC51A) Control by external command using G-way
• NIM controller
• Communication bus
The G-way controls consist of:
NIM utilizes master-slave configurations. One master can control up to 15 slave
units in a group. The master unit operates in conjunction with a control panel. Any • Mainboard
settings done via the control panel connected to the master overwrite the settings • Control panel (BRC51A)
of its slave units. Slave units can be operated with or without control panel. If a • G-way controller
slave unit is operating with a control panel, its settings can be changed without • Communication bus
following its master’s.
It is a gateway between the air conditioning unit and basic Building
• DIP switch setting for group and unit address Management System (BMS). G-way controller enables:
• Automatic detection of control panel
• Error codes and error unit’s ID indication on control panel • Remote (ON/OFF) of air conditioner via BMS.
• Supported configurations of NIM: • Unit error indication via BMS and BRC51A controller.
• Unit operation status monitoring via BMS.
Master Slave
• DIP switch setting for control or monitoring function.
BRC51A • Maximum point-to-point distance of 1000m.
NIM controller BRC52A G-way controller

11 12
Control by external command using BMS Access Gateway (BAG) Abundance of functions that provide comfortable air-conditioning in stores and offices
BAG interfaces the air conditioner unit to BMS system via input contacts,
resistance inputs and dry contacts outputs which allows the monitoring
Comfort
and controls of the air conditioner. The BAG enables:
Auto-swing Two selectable temperature-sensors
• Controls of the air conditioner unit’s ON/OFF status, operating mode, Delivers comfortable air-conditioning to all areas, near Temperature-sensors are included in the indoor unit
fan speed setting, room temperature setting as well as forcing off the unit in to and far from the air-conditioner. and optional wired remote controller. temperature
the event of fire. sensing closer to target area is possible to further
• Indication to warn the control room in the event of air conditioner failure. increase the comfort level.
• Maximum point-to-point distance of 1100m (please refer to the Swing pattern selection
You can freely set 3 air discharge setting by remote controller. Use the temperature-sensor in the indoor unit when
installation manual)
controlling air conditioning from another room.

Inputs Inputs Controls Applications 1) Air direction in standard setting


BAG controller Input Force off/unchange Smoke alarm system
contacts ON/OFF Long distance unit ON/OFF control
The BAG controls consist of: 2) Air direction in draft prevention
Resistance Temperature setting Long distance unit temperature
setting
(16˚C-30˚C) setting control
• Mainboard Inputs

• Control panel (BRC51A) Outputs Output Indications Applications


• BAG controller Relay ON/OFF Status 3) Air direction in ceiling soiling
Long distance unit operation status monitoring prevention setting
• Communication bus outputs Unit faulty / normal
Note: Wireless remote controllers have no temperature-sensor

Individual air conditioners can be turned on from the control room’s Input Contact
Switchable fan speed (*available on all models) Timer selector
connection Selectable High, Medium and Low fan speed. High Operation starts when the preset time of the ON
setting provides maximum reach while low setting timer elapse and stops when the preset time of the
minimizes drafts. OFF timer elapses.

Programme “Dry” (*available on all models) Weekly schedule timer


Dehumidification is microprocessor controlled to Available in Timer 1 & Timer 2 with operation
prevent abrupt and uncomfortable changes in air ON/OFF settings programmed for 7 days of the
temperature. Useful for reducing uncomfortable week.
humidity without uncomfortable cooling of the room.

Cleanliness
Washable saranet filter
Removal of air-borne dust particles through saranet filter ensures cleaner air supply.
BAG
BAG

BAG
Work and Servicing
BAG

Comparison between G-way controls and BAG controls Drain pump mechanism
Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.
Features G-way BAG
Force Off
ON/OFF
Pre-charge for up to 7.5 metres
Input Contacts Operating Mode
If refrigerant piping length does not exceed 7.5m, there is no need for on-site gas charging. However for any piping
Fan Speed
length more than 7.5m, requires for additional charge.
(Applies for all models)
Set Temperature
ON/OFF Status
Dry Contact
Outputs
Operating Mode Self diagnosis function (*available on all models)
Fault Status
The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the
Note: system, are constantly monitored using a microcomputer. This intelligent feature helps to detect faults or
Communication Bus malfunctioning in the system and give user a warning by blinking of the LED light on the unit or display error code
A 2-way twisted pair cable is used as the communication bus. Recommended cable for communication bus is a pair of screened & shielded, wisted single core wire with on the wired controller.
core diameter of 0.5mm to 1.0mm.

13 14
Auto random restart (*available on all models)
Control features
Specifications
If there is a power outage while the equipment is operating, operations will restart randomly (within 180 to 244
seconds) in the same mode as before the power cut when electricity is restored.
Ceiling cassette
Group control by Network Interface Module (NIM) Capacity PK 2.0 2.5 3.0 3.0 3.5 4.0

You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the Indoor unit FCRN50FXV14 FCRN60FXV14 FCRN71FXV14 FCRN71FXV14 FCRN100FXV14 FCRN125FXV14
settings must all be the same and on/off will be simultaneous.) Model Outdoor unit RN50CXV1A4 RN60CXV1A4 RR71CXV1A4 RR71CXY1A4 RR100DXY1A4 RR125DXY1A4

External command control using G-way or BAG


Decoration panel BC50F2XW4

Btu/hr 18,500 23,000 28,000 28,000 36,000 42,000


Operation and surveillance is carried out using the contact signal from the operation control box in the building Nominal cooling capacity
kW 5.4 6.8 8.2 8.2 10.6 12.3
surveillance (security) room. Nominal total input power W 1,760 2,050 2,930 2,900 3,660 4,110
Nominal COP W/W 3.08 3.29 2.80 2.83 2.88 3.00

Power supply V/Ph/Hz 220-240/1/50 (power from outdoor) 380-415/3/50 (power from outdoor)

Options
Airflow (H/M/L/Q) cfm 730/620/510/360 840/700/560/440 890/760/620/490 890/760/620/491 1030/870/730/580 1120/1030/890/760

Sound pressure level (H/M/L/Q) dB(A) 38/35/33/29 39/37/34/31 41/38/35/32 41/38/35/33 46/41/37/34 48/45/41/37

Indoor unit
Unit mm 246x840x840 246x840x840 246x840x840 246x840x841 288x840x840 288x840x840

Fresh-air intake kit


Dimensions
(HxWxD)
with decoration panel mm 301x950x950 301x950x950 301x950x950 301x950x951 343x950x950 343x950x950

You can provide air-conditioning with fresh air from outside. Unit kg 22 22 22 22 25 25
It is convenient for places where a ventilation fan cannot be installed. Machine weight
decoration panel kg 5 5 5 5 5 5

Sound pressure level dB(A) 52 52 56 56 58 60


Note: * Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.
Dimensions (HxWxD) mm 651x855x328 651x855x328 753x855x328 753x855x329 852x1030x400 852x1030x400

Outdoor unit
Machine weight kg 43 47 57 56 71 95

Liquid (Flare) mm 6.35 6.35 9.52 9.52 9.52 9.52


Piping connections
Gas (Flare) mm 12.70 15.88 15.88 15.88 15.88 15.88
Max. interunit piping length m 30 30 45 45 50 50

Max. installation level difference m 15 15 25 25 30 30

1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length: 7.5m

Floor standing
Capacity PK 3.0 3.0 3.5 4.0 5.0

Indoor unit FVRN71BXV14 FVRN71BXV14 FVRN100BXV14 FVRN125BXV14 FVRN140BXV14


Model
Outdoor unit RR71CXV1A4 RR71CXY1A4 RR100DXV1A4 RR125DXY1A4 RR140DXY1A4

Btu/hr 29,000 28,000 36,000 42,000 55,000


Nominal cooling capacity
kW 8.5 8.2 10.6 12.3 16.1

Nominal total input power W 2,900 2,850 3,550 4,100 5,490

Nominal COP W/W 2.93 2.88 2.97 3.00 2.94

220-240/1/50 380-415/3/50
Power supply V/Ph/Hz
(power from outdoor) (power from outdoor)

Airflow (H/M/L) cfm 675/625/530 675/625/530 1035/945/845 1035/945/845 1170/1085/985

Indoor unit
Sound pressure level (H/M/L) dB(A) 44/42/39 44/42/39 49/47/44 49/47/44 54/53/51

Dimensions (HxWxD) mm 1850x600x270 1850x600x270 1850x600x350 1850x600x350 1850x600x350

Machine weight kg 42 42 45 45 51

Sound pressure level dB(A) 56 56 58 60 65


Outdoor unit Dimensions (HxWxD) mm 753x855x328 753x855x328 852x1030x400 852x1030x400 852x1030x400

Machine weight kg 57 56 71 95 105

Liquid (Flare) mm 9.52 9.52 9.52 9.52 9.52


Piping connections
Gas (Flare) mm 15.88 15.88 15.88 15.88 19.05

Max. interunit piping length m 45 45 50 50 45

Max. installation level difference m 25 25 30 30 25

1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length: 7.5m

15 16
Note:

17