0% found this document useful (0 votes)
148 views8 pages

Industrial Solenoid Valve Specs

The document summarizes an electromagnetic solenoid valve called the ICO3S. It has 2/2, 3/2 or 5/2 poppet valves and is direct solenoid operated. It is suitable for pneumatic or hydraulic applications up to 12 bar inlet pressure. It has various port sizes and configurations, materials include stainless steel and NBR seals. It provides flow rates from 0.6 to 3.3 Cv and operates from -55 to +90°C. It has certifications like ATEX and is NEMA 4X rated for environmental protection.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
148 views8 pages

Industrial Solenoid Valve Specs

The document summarizes an electromagnetic solenoid valve called the ICO3S. It has 2/2, 3/2 or 5/2 poppet valves and is direct solenoid operated. It is suitable for pneumatic or hydraulic applications up to 12 bar inlet pressure. It has various port sizes and configurations, materials include stainless steel and NBR seals. It provides flow rates from 0.6 to 3.3 Cv and operates from -55 to +90°C. It has certifications like ATEX and is NEMA 4X rated for environmental protection.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

ICO3S

2/2, 3/2 or 5/2 poppet valves


Electromagnetically actuated, direct solenoid operated
1/4 NPT ... 1/2 NPT, G 1/4 ... G 1/2, Namur or manifold versions

Direct acting solenoid valve


High flow
12 bar inlet pressure
Reliable and long life, ideal for a one time
installation
Control of pneumatic or hydraulic operated
equipment
Certifications: ATEX, CSA, GOST K & R, IECEx,
FM, CSA, CRN, CCOE, IN-METRO, KOSHA FM
APPROVED
Environmental Protection: NEMA 4X, IP66/X8

Technical features
Medium: Flow: Fluid temperature:
Materials:
Hydraulic and pneumatic – 0,6 Cv (8,7Kv) ... 3.3 Cv (46.4 Kv) -55 ... +90°C (-67 ... +194°F)
Valve body, trim, coil housing and
customer to specify and confirm Port size: Ambient temperature:
top cover:
compatibility G 1/4, 1/2 NPT, G 1/4, G 1/2 See table on page 2
stainless steel 1.4404 (316 L)
Operation: NAMUR or manifold versions Air supply must be dry enough
O-rings seats & seals: NBR
Direct solenoid operated Operating pressure: to avoid ice formation at
poppet valves 0 ... 12 bar (0 ... 174 psi) temperatures below 2°C (+35°F).
Other seal materials available on
Mounting position:
request
Solenoid vertical

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.7.540.01
ICO3S

Technical data – standard models with conduit connection M20 x 1,5


Symbol Port Function Operating Manual ATEX Power Ambient Weight Dimension Model
size pressure override/ certification consumption temperature
(bar) reset at 24 Vdc (W) (kg) No.
2 1/4 NPT 2/2 NC 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 1 Y011AA1H1BS
G 1/4 2/2 NC 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 1 Y011AE1H1BS
1

2 1/4 NPT 2/2 NC 0 ... 12 JSMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.0 2 Y011SA1H1BS
G 1/4 2/2 NC 0 ... 12 JSMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.0 2 Y011SE1H1BS
1

1/4 NPT 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 3 Y013AA1H1BS
2
G 1/4 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 3 Y013AE1H1BS
1/2 NPT 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 4 Y013AA3H1BS
1 3
G 1/2 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 4 Y013AE3H1BS
2 1/4 NPT 3/2 UNI 0 ... 12 JSMO* Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 5 Y013SA1H1BS
G 1/4 3/2 UNI 0 ... 12 JSMO* Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 5 Y013SE1H1BS
1 3

2 1/4 NPT 3/2 UNI 0 ... 12 TPMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 6 Y013TA1H1BS
G 1/4 3/2 UNI 0 ... 12 TPMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,5 6 Y013TE1H1BS
1 3

1/4 NPT 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 7 Y013PA1H1BS
2
G 1/4 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,0 7 Y013PE1H1BS
1/2 NPT 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 8 Y013CA3H1BS
1 3
G 1/2 3/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 8 Y013CE3H1BS
2 1/2 NPT 3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,8 8 Y013PA3H1BS
G 1/2 3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,8 8 Y013PE3H1BS
1 3

Manifold 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2,8 9 Y013AKFH1BS

3 1 2

2 2 1/4 NPT NAMUR 3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.5 10 Y013PNAH1BS
G 1/4 NAMUR 3/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C), T4 (+90°C max) 2.5 10 Y013PNEH1BS
1 3

4 2 1/4 NPT 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,8 11 Y015AA1H1BS
G 1/4 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,8 11 Y015AE1H1BS
513 NAMUR 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,3 14 Y015ANAH1BS
4 2 1/4 NPT 5/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,3 12 Y015CA1H1BS
G 1/4 5/2 UNI 0 ... 12 PBMO*1) Ex II 2 GD, Exd IIC 2 T6 (-55 … +50°C), T4 (+90°C max) 2,3 12 Y015CE1H1BS
513

4 2 1/4 NPT 5/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 2 T6 (-55 … +50°C), T4 (+90°C max) 2,5 13 Y015PA1H1BS
G 1/4 5/2 UNI 0 ... 12 PBMR*1) Ex II 2 GD, Exd IIC 7,8 T6 (-55 … +50°C), T4 (+90°C max) 2,5 13 Y015PE1H1BS
513

*1) PBMR = Push button manual reset, PBMO = Push button manual override, JSMO = Jack screw manual override,
TMRP = Tamperproof manual reset button

N/en/en 5.7.540.02 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12
ICO3S

Option selector Y˙1˙˙˙˙˙˙˙S


ATEX certification Substitute Voltage / Signal Substitute
Ex d O 24 V d.c. B
Ex mbe Z 50 V d.c. C
Ex ia* X 110 V d.c. D
Operation Substitute 125 V d.c. E
2/2 NC 1 24 V a.c. G
2/2 NO 2 110 V a.c. J
3/2 3 220 /240 V a.c. (240 V) M
5/2 5 120 V a.c. T
Operation Substitute Conduit / Signal connection Substitute
Automatic A 20mm x 1.5mm ISO (F) 1
Push button manual override C 1/2 NPT (F) 2
Push button manual reset P Seat /seal material Substitute
Tamper proof manual reset T Nitrile (-55° ... +90 °C) H
Jackscrew manual override S FKM (-20° ... +90 °C) V
Port size Substitute
1/4 NPT A1
G 1/4 E1
1/2 NPT A3
G 1/2 E3
NAMUR NA
Manifold KF
* For Zone 0 - see separate catalogue
section.

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.7.540.03
ICO3S

Dimensions Dimensions shown in mm


Projection/First angle
1 2
47 ø 58 47 ø 58

1 1

28

28
2 2

22

22
157

157
2 2
1 1
27,5

27,5
6

16

16
11 25,5

24
15,5

15,5
27
11 5 25,5
50
27
50

3 4
47 ø 58 47 ø58

1 1

28
28

2 2

22
22

187
157

3 3
2
39

1 2
27,5

26
6

16

66
42
42

11 25,5 1
15,5

18
18

27
6,5

50 44 26
65

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
5 Jack screw manual override (JSMO)

N/en/en 5.7.540.04 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12
ICO3S

Dimensions shown in mm
5 6
Projection/First angle

47 ø 58 47 ø 58

1 1

28
28
2 2

22
22

157
157
3 3
2 2

39
1 39 1
27,5

27

26
26

15

16
6
6

16
24

11 25
15,5

11
11 5 25,5 27
27 50
50

7 8
47 ø 58 47 ø58

1 1

28
28

2 2

22
22

187
157

3 3
2
39

1 2
27

26
15

16
6

66
42
42

11 25 1
3

3
13 18
18
6,5

27
50
44 3 26
65

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 Push button manual reset (PBMR)
4 Push button manual override (PBMO)
6 Tamer proof manual reset (TPMR)

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.7.540.05
ICO3S

Dimensions shown in mm
9
Projection/First angle

47 ø58

28
2

22

157
6,5
3
2

39
1

26
25

16
ø5
ø8,8

51 38
51

10
47 ø 58

1 28

2
22

157

1
39
5,5
36

3
14

16
12
12

19,5 1,6 3 51
32 64

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 Push button manual reset (PBMR)

N/en/en 5.7.540.06 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12
ICO3S

Dimensions shown in mm
11 12
Projection/First angle

47 ø58 47 ø58

1 1

28

28
2 2

22

22
177

177
5 5
4 4
1 1
59

59
2
43

43
36

36
3 3
20

20
12

12
50 30
50 3 30

6
47 ø58
13
1
28

2
22

177

5
4
1
59

2
43

36

3
20

11 12

50 4 30

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 Manual override PBMO
4 Manual override PBMR

11/12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/en/en 5.7.540.07
ICO3S

Dimensions shown in mm
14 47 ø58
Projection/First angle
1

28
2

22

177
5
4
1

59
5,5
46

2
34

36
3
22

12
19,6 1,6 51
3

32

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth

Warning
These products are intended for use in industrial compressed air equipment in the event of such failure.
systems only. Do not use these products where pressures and System designers must provide a warning to end users in the system
temperatures can exceed those listed under »Technical features«. instructional manual if protection against a failure mode cannot be
adequately provided.
Before using these products with fluids other than those specified,
for non-industrial applications, life-support systems, or other System designers and end users are cautioned to review specific
applications not within published specifications, consult NORGREN. warnings found in instruction sheets packed and shipped with these
Through misuse, age, or malfunction, components used in fluid products.
power systems can fail in various modes. Functional safety (SIL):
The system designer is warned to consider the failure modes of Suitable for certain applications can only be evaluated through
all component parts used in pneumatic systems and to provide examination of each safety-related overall system with regard to the
adequate safeguards to prevent personal injury or damage to requirements of IEC 61508/61511.

N/en/en 5.7.540.08 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11/12

You might also like