ELECTRIFIED DOUBLE TRACK PROJECT
BETWEEN
UEM CONSTRUCTION RAWANG AND IPOH (BALANCE OF WORKS)
TEST CERTIFICATE
Test Conducted For : TRACKWORK Form No
INSPECTION DETAIL FOR TRACKWORK
Serial No :
1. Location :_____________________________________ 5. Status of Test : 1st. _______ 2nd. _______ 3rd. _________
2. Offset :_____________________________________
3. Chainages : From_____________to_________________
4. Date of Laying :_____________________________________
CURVE CHAINAGE FROM CH. TO CH. STRAIGHT CHAINAGE FROM CH TO CH REMARKS
Curve No :
Radius :
Length of Transition BTC
ETC
Length of Circular Curve BCC
ECC
Length of Transition BTC
ETC
TEST SPEC. REQUIREMENT SITE RESULTS REMARKS
1. Super Elevation
2. Versine (@10 m Chord)
3. Difference in Versine
4. Difference in S. Elevation
5. Gauge
i) Static +2 -1
ii) Dynamic +3 -1
iii) Variation between +2 -2
adjacent sleeper
6. Cross Level
i) Static +1.5 -1.5
ii) Dynamic +3 -2
7. Vetical Alignment over 10m Chord
i) Static +2 -4
ii) Dynamic +3 -3
8. Laterval Alignment over 10m Chord
i) Static +2 -2
ii) Dynamic +4 -4
9. Twist (1.8m base & 3 measures/
25m intervals)
i) Static +1 mm/m
ii) Dynamic +2 mm/m
10. Sleeper Spacing 5mm
Supervising Consultant
Name : Signature : Date :
Contractor
Name : Signature : Date :
UEMC-F-TW033 Rev 0 Date: 01-06-05