Gelo HARDNESS REPORT For PB Sheet

This hardness test report provides the results of microhardness tests conducted on samples of 0.20mm CuSn6 sheet material. The tests were performed according to ASTM E 384-17 using a load of 200gf and a diamond pyramid indenter. Three indentations were made on each of two samples and the average Vickers hardness values were determined to be 253.9 HV for sample 1 and 338.83 HV for sample 2.

Uploaded by

P NAVEEN KUMAR
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
91 views1 page

Gelo HARDNESS REPORT For PB Sheet

This hardness test report provides the results of microhardness tests conducted on samples of 0.20mm CuSn6 sheet material. The tests were performed according to ASTM E 384-17 using a load of 200gf and a diamond pyramid indenter. Three indentations were made on each of two samples and the average Vickers hardness values were determined to be 253.9 HV for sample 1 and 338.83 HV for sample 2.

Uploaded by

P NAVEEN KUMAR
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

HARDNESS TEST REPORT

CUSTOMER NAME & ADDRESS: Work order No. CMSS/20/1042


Test Report No/ULR No. TC6850200000003172P
Date of Receipt of test Item 09-07-2020
GELO TECHNOLOGIES PVT. LTD.
Date of testing 10-07-2020
Plot #38, Phase II, IDA, Cherlapally,
Hyderabad- 500 051.
Issue Date of Test Report 10-07-2020
Material CuSn6
Sample Description 0.20mm CuSn6 sheet

Identification of the sample 0.20mm CuSn6 sheet-1 & 2

S.NO Test Details


Machine Details HARDNESS TEST PARAMETERS
Name: HARDNESS TESTER Test Procedure : ASTM E 384-17
1 Srl. No: 3266 Load applied : 200gf(load)
Calibration on Date : 08-12-2019 Type of Hardness : Microhardness(HV)
Calibration Due Date : 07-12-2020 Indenter : 136⁰ Diamond Pyramid
Location : On surface

Observed Values in HV Avg


Value in HV
Identification
S.ID of the
sample
Impression 1 Impression 2 Impression 3

0.20mm
1 252.4 254.3 255 253.9
CuSn6 sheet-1
0.20mm
2 334.8 340.8 340.9 338.83
CuSn6 sheet-2

-------------------------------------------End of the test report----------------------------------------


Verified by Witnessed by for CRYSTAL METALLURGICAL SERVICES & SOLUTIONS

Format No. CMSS/FM/48(HN) Authorized Signature


Rev No.00: DT: 01/01/2016 (P.NAVEEN KUMAR)