Industrial
Management Ethernet Switch
IES-3073GC Series User’s Manual
Version 1.3
Feb, 2010
ORing Industrial Networking Corp.
4F., NO.3, Lane235, Baociao Rd.Sindian City,
Taipei County 23145 Taiwan, R.O.C.
Tel: + 886 2 2918 3036
Fax: + 886 2 2918 3084
Website: www.oring-networking.com
E-mail: [email protected]
IES-3073GC User’s Manual
Table of Content
Getting to Know Your Switch........................................................................4
1.1 About the IES-3073GC Managed Industrial Switch.......................................................4
1.2 Software Features ..............................................................................................................4
1.3 Hardware Features.............................................................................................................5
Hardware Installation.....................................................................................6
2.1 Installing Switch on DIN-Rail.............................................................................................6
2.1.1 Mount IES-3073GC on DIN-Rail.....................................................................................6
2.2 Wall Mounting Installation..................................................................................................7
2.2.1 Mount IES-3073GC Series on the wall ............................................................................7
Hardware Overview........................................................................................9
3.1 Front Panel ..........................................................................................................................9
3.2 Front Panel LEDs ............................................................................................................. 11
3.3 Top view Panel ..................................................................................................................12
3.4 Rear Panel .........................................................................................................................12
Cables ...........................................................................................................13
4.1 Ethernet Cables ................................................................................................................13
4.1.1 100BASE-TX/10BASE-T Pin Assignments...................................................................13
4.2 SFP .....................................................................................................................................14
4.3 Console Cable...................................................................................................................15
WEB Management........................................................................................16
5.1 Configuration by Web Browser .......................................................................................16
5.1.1 About Web-based Management ......................................................................................16
5.1.2 System Information ........................................................................................................18
5.1.3 Front Panel......................................................................................................................18
5.1.4 Basic setting....................................................................................................................19
5.1.4.1 Switch Setting .......................................................................................................19
5.1.4.2 Admin Password ...................................................................................................20
5.1.4.3 IP Setting...............................................................................................................20
5.1.4.4 SNTP (Time) .........................................................................................................21
5.1.4.5 LLDP.....................................................................................................................24
ORing Industrial Networking Corp 1
IES-3073GC User’s Manual
5.1.4.6 Auto Provision ......................................................................................................24
5.1.4.7 Backup & Restore .................................................................................................25
5.1.4.8 Upgrade Firmware ................................................................................................25
5.1.5 DHCP Server ..................................................................................................................26
5.1.5.1 DHCP Server – Setting..........................................................................................26
5.1.5.2 DHCP Server – Client List....................................................................................27
5.1.5.3 DHCP Server – Port and IP bindings ....................................................................27
5.1.6 Port Setting .....................................................................................................................28
5.1.6.1 Port Control...........................................................................................................28
5.1.6.2 Port Status .............................................................................................................28
5.1.6.3 Port Alias...............................................................................................................29
5.1.6.4 Rate Limit .............................................................................................................30
5.1.6.5 Port Trunk .............................................................................................................31
5.1.7 Redundancy ....................................................................................................................33
5.1.7.1 O-Ring...................................................................................................................33
5.1.7.2 Open-Ring.............................................................................................................34
5.1.7.3 O-RSTP.................................................................................................................35
5.1.7.4 RSTP .....................................................................................................................36
5.1.7.5 MSTP ....................................................................................................................39
5.1.8 VLAN .............................................................................................................................43
5.1.8.1 VLAN Setting .......................................................................................................43
5.1.8.2 VLAN Setting – Port Based ..................................................................................45
5.1.9 SNMP .............................................................................................................................47
5.1.9.1 SNMP – Agent Setting ..........................................................................................47
5.1.9.2 SNMP – Trap Setting ............................................................................................48
5.1.10 Traffic Prioritization...................................................................................................49
5.1.11 Multicast ....................................................................................................................53
5.1.11.1 IGMP Snooping.....................................................................................................53
5.1.11.2 MVR .....................................................................................................................54
5.1.11.3 Multicast Filter ......................................................................................................55
5.1.12 Security ......................................................................................................................56
5.1.12.1 IP Security.............................................................................................................56
5.1.12.2 Port Security..........................................................................................................57
5.1.12.3 MAC Blacklist ......................................................................................................58
5.1.12.4 802.1x....................................................................................................................58
5.1.13 Warning......................................................................................................................61
5.1.13.1 Fault Alarm ...........................................................................................................61
ORing Industrial Networking Corp 2
IES-3073GC User’s Manual
5.1.13.2 System Alarm........................................................................................................62
5.1.14 Monitor and Diag.......................................................................................................65
5.1.14.1 MAC Address Table ..............................................................................................65
5.1.14.2 MAC Address Aging .............................................................................................66
5.1.14.3 Port Statistics.........................................................................................................66
5.1.14.4 Port Monitoring.....................................................................................................67
5.1.14.5 System Event Log .................................................................................................68
5.1.14.6 SFP Monitor ..........................................................................................................69
5.1.14.7 Ping .......................................................................................................................70
5.1.15 Save Configuration ....................................................................................................71
5.1.16 Factory Default ..........................................................................................................71
5.1.17 System Reboot ...........................................................................................................72
Command Line Interface Management ......................................................72
6.1 About CLI Management .................................................................................................72
6.2 Commands Set List—System Commands Set................................................................78
6.3 Commands Set List—Port Commands Set .....................................................................80
6.4 Commands Set List—Trunk command set .....................................................................83
6.5 Commands Set List—VLAN command set....................................................................84
6.6 Commands Set List—Spanning Tree command set........................................................85
6.7 Commands Set List—QoS command set........................................................................87
6.8 Commands Set List—IGMP command set.....................................................................88
6.9 Commands Set List—MAC/Filter Table command set ..................................................89
6.10 Commands Set List—SNMP command set ....................................................................89
6.11 Commands Set List—Port Mirroring command set .......................................................90
6.12 Commands Set List—802.1x command set....................................................................91
6.13 Commands Set List—TFTP command set......................................................................93
6.14 Commands Set List—SYSLOG, SMTP, EVENT command set .....................................94
6.15 Commands Set List—SNTP command set .....................................................................95
6.16 Commands Set List—O-Ring command set...................................................................97
Technical Specifications .............................................................................98
ORing Industrial Networking Corp 3
IES-3073GC User’s Manual
Getting to Know Your Switch
1.1 About the IES-3073GC Managed Industrial
Switch
The IES-3073GC is powerful managed industrial switch with many features. The switch can
work under wide temperature, dusty environment and humid condition. They can be
managed by WEB, TELNET, Console or other third-party SNMP software as well. Besides,
the switch can be managed by a useful utility that we called Open-Vision. Open-Vision is
powerful network management software. With its friendly and powerful interface, you can
easily configure multiple switches at the same time, and monitor switches’ status.
1.2 Software Features
World’s fastest Redundant Ethernet Ring (Recovery time < 10ms over 250 units
connection)
Supports Ring Coupling, Dual Homing over O-Ring
Supports SNMPv1/v2c/v3 & RMON & Port base/802.1Q VLAN Network Management
Event notification by Email, SNMP trap and Relay Output
Web-based ,Telnet, Console, CLI configuration
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
VLAN (802.1Q ) to segregate and secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
RSTP (802.1w)
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with double tagging and GVRP supported
IGMP Snooping for multicast filtering
Port configuration, status, statistics, mirroring, security
Remote Monitoring (RMON)
ORing Industrial Networking Corp 4
IES-3073GC User’s Manual
1.3 Hardware Features
Redundant dual DC power inputs
Wide Operating Temperature: -40 to 70oC
Storage Temperature: -40 to 85oC
Operating Humidity: 5% to 95%, non-condensing
Casing: IP-30
10/100/1000Base-T(X) Gigabit Ethernet port (combo port)
10/100Base-T(X) Ethernet port
1000Base-X on SFP port (combo port)
Console Port
Dimensions(W x D x H) :74.3 mm(W)x 109.2 mm( D )x 153.6 mm(H)
ORing Industrial Networking Corp 5
IES-3073GC User’s Manual
Hardware Installation
2.1 Installing Switch on DIN-Rail
Each switch has a DIN-Rail kit on rear panel. The DIN-Rail kit helps switch to fix on the
DIN-Rail. It is easy to install the switch on the DIN-Rail:
2.1.1 Mount IES-3073GC on DIN-Rail
Step 1: Slant the switch and mount the metal spring to DIN-Rail.
Metal Spring
Step 2: Push the switch toward the DIN-Rail until you heard a “click” sound.
ORing Industrial Networking Corp 6
IES-3073GC User’s Manual
2.2 Wall Mounting Installation
Each switch has another installation method for users to fix the switch. A wall mount panel
can be found in the package. The following steps show how to mount the switch on the wall.
2.2.1 Mount IES-3073GC on the wall
Step 1: Remove DIN-Rail kit.
Step 2: Use 6 screws that can be found in the package to combine the wall mount panel. Just
like the picture shows below:
ORing Industrial Networking Corp 7
IES-3073GC User’s Manual
The screws specification shows in the following two pictures. In order to prevent switches
from any damage, the screws should not larger than the size that used in IES-3073GC switch.
Pozidrive
ORing Industrial Networking Corp 8
IES-3073GC User’s Manual
Hardware Overview
3.1 Front Panel
The following table describes the labels that stick on the IES-3073GC.
Port Description
10/100 RJ-45 fast 7 10/100Base-T(X) RJ-45 fast Ethernet ports support
Ethernet ports auto-negotiation.
Default Setting :
Speed: auto
Duplex: auto
Flow control : disable
Gigabit RJ-45 port 3 10/100/1000Base-TX Gigabit ports (combo port)
Fiber port 3 100/1000Base-X on SFP port (combo port)
Console Use RS-232 to RJ-45 connecter to manage switch.
Reset Push reset button 2 to 3 seconds to reset the switch.
Push reset button 5 seconds to reset the switch into Factory
Default.
ORing Industrial Networking Corp 9
IES-3073GC User’s Manual
IES-3073GC
1. LED for PWR. When the PWR links, the green led will be light on.
2. LED for PWR1. When the PWR1 links, the green led will be light on.
3. LED for PWR2. When the PWR2 links, the green led will be light on.
4. LED for R.M (Ring master). When the LED light on, it means that the switch is the ring
master of O-Ring.
5. LED for Ring. When the led light on, it means the O-Ring is activated.
6. LED for Fault Relay. When the fault occurs, the amber LED will be light on.
7. Console port (RJ-45).
8. Reset button. Push the button 3 seconds for reset; 5 seconds for factory default.
9. LED for Ethernet ports speed.
10. LED for Ethernet ports link status.
11. 10/100Base-T(X) Ethernet ports.
12. Gigabit combo ports with SFP and RJ-45 connectors
ORing Industrial Networking Corp 10
IES-3073GC User’s Manual
3.2 Front Panel LEDs
LED Color Status Description
PWR Green On DC power ready
PW1 Green On DC power module 1 activated.
PW2 Green On DC power module 2 activated.
R.M Green On O-Ring Master.
On O-Ring enabled.
Ring Green Slowly blinking O-Ring topology has problem
Fast blinking O-Ring work normally.
Fault relay. Power failure or
Fault Amber On
Port down/fail.
10/100Base-T(X) Fast Ethernet ports
On Port link up.
LNK / ACT Green
Blinking Data transmitted.
Full Duplex Amber On Port works under full duplex.
Gigabit Ethernet ports (combo ports)
On Port link up.
LNK/ACT Green
Blinking Data transmitted.
Speed Amber On Port working at 100Mbps
Gigabit SFP ports (combo ports)
On Port link up.
LNK / ACT Green
Blinking Data transmitted.
ORing Industrial Networking Corp 11
IES-3073GC User’s Manual
3.3 Top view Panel
The bottom panel components of IES-3073GC are showed as below:
1. Terminal block includes: PWR1, PWR2 (48V DC)
2. Ground wire
3.4 Rear Panel
The components in the rare of IES-3073GC is shown as below:
1. Screw holes for wall mount kit.
2. DIN-Rail kit
ORing Industrial Networking Corp 12
IES-3073GC User’s Manual
Cables
4.1 Ethernet Cables
The IES-3073GC switch have standard Ethernet ports. According to the link type, the
switch use CAT 3, 4, 5, 5e UTP cables to connect to any other network device (PCs, servers,
switches, routers, or hubs). Please refer to the following table for cable specifications.
Cable Types and Specifications
Cable Type Max. Length Connector
10BASE-T Cat.3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat.5 100-ohm UTP UTP 100 m (328 ft) RJ-45
1000BASE-TX Cat.5/Cat.5e 100-ohm UTP UTP 100 m (328ft) RJ-45
4.1.1 100BASE-TX/10BASE-T Pin Assignments
With 100BASE-TX/10BASE-T cable, pins 1 and 2 are used for transmitting data, and
pins 3 and 6 are used for receiving data.
RJ-45 Pin Assignments
Pin Number Assignment
1 TD+
2 TD-
3 RD+
4 Not used
5 Not used
6 RD-
7 Not used
8 Not used
The IES-3073GC switch support auto MDI/MDI-X operation. You can use a
straight-through cable to connect PC to switch. The following table below shows the
10BASE-T/ 100BASE-TX MDI and MDI-X port pin outs.
ORing Industrial Networking Corp 13
IES-3073GC User’s Manual
MDI/MDI-X pins assignment
Pin Number MDI port MDI-X port
1 TD+(transmit) RD+(receive)
2 TD-(transmit) RD-(receive)
3 RD+(receive) TD+(transmit)
4 Not used Not used
5 Not used Not used
6 RD-(receive) TD-(transmit)
7 Not used Not used
8 Not used Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
4.2 SFP
The IES-3073GC has fiber optical ports with SFP connectors. The fiber optical ports are in
multi-mode (0 to 550M, 850 nm with 50/125 µm, 62.5/125 µm fiber) and single-mode with LC
connector. Please remember that the TX port of Switch A should be connected to the RX port
of Switch B.
Switch A Switch B
Fiber cord
ORing Industrial Networking Corp 14
IES-3073GC User’s Manual
4.3 Console Cable
IES-3073GC switch can be management by console port. The DB-9 to RJ-45 cable can be
found in the package. You can connect them to PC via a RS-232 cable with DB-9 female
connector and the other end (RJ-45 connector) connects to console port of switch.
PC pin out (male) assignment RS-232 with DB9 female connector DB9 to RJ 45
Pin #2 RD Pin #2 TD Pin #2
Pin #3 TD Pin #3 RD Pin #3
Pin #5 GD Pin #5 GD Pin #5
ORing Industrial Networking Corp 15
IES-3073GC User’s Manual
WEB Management
5.1 Configuration by Web Browser
This section introduces the configuration by Web browser.
5.1.1 About Web-based Management
An embedded HTML web site resides in flash memory on the CPU board. It contains
advanced management features and allows you to manage the switch from anywhere on the
network through a standard web browser such as Microsoft Internet Explorer.
The Web-Based Management function supports Internet Explorer 5.0 or later. It is based
on Java Applets with an aim to reduce network bandwidth consumption, enhance access
speed and present an easy viewing screen.
Note: By default, IE5.0 or later version does not allow Java Applets to open sockets. You need to explicitly modify
the browser setting in order to enable Java Applets to use network ports.
Preparing for Web Management
The default value is as below:
IP Address: 192.168.10.1
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.10.254
User Name: admin
Password: admin
System Login
1. Launch the Internet Explorer.
2. Type http:// and the IP address of the switch. Press “Enter”.
ORing Industrial Networking Corp 16
IES-3073GC User’s Manual
3. The login screen appears.
4. Key in the username and password. The default username and password is
“admin”.
5. Click “Enter” or ”OK” button, then the main interface of the Web-based
management appears.
Login screen
Main Interface
Main interface
ORing Industrial Networking Corp 17
IES-3073GC User’s Manual
5.1.2 System Information
System Information interface
System Information
The system information will display the configuration of Basic Setting / Switch Setting page.
Enable Location Alert
When click , PWR1 and PWR2 LEDs of the switch will start to
flash together, and click , the LEDs will stop flashing.
5.1.3 Front Panel
Show the panel of IES-3073GC. Click “Close” to close panel on web.
ORing Industrial Networking Corp 18
IES-3073GC User’s Manual
5.1.4 Basic setting
5.1.4.1 Switch Setting
Switch setting interface
The following table describes the labels in this screen.
Label Description
System Name Assign the name of switch. The maximum length is 64 bytes
System Description Display the description of switch.
System Location Assign the switch physical location. The maximum length is 64
bytes
System Contact Enter the name of contact person or organization
System OID Display the switch’s OID information
Firmware Version Display the switch’s firmware version
Kernel Version Display the kernel software version
MAC Address Display the unique hardware address assigned by manufacturer
(default)
ORing Industrial Networking Corp 19
IES-3073GC User’s Manual
5.1.4.2 Admin Password
Change web management login username and password for the management security
issue
Admin Password interface
The following table describes the labels in this screen.
Label Description
User name Key in the new username (The default is “admin”)
New Password Key in the new password (The default is “admin”)
Confirm password Re-type the new password.
Apply Click “Apply” to activate the configurations.
5.1.4.3 IP Setting
You can configure the IP Settings and DHCP client function through IP configuration.
IP Configuration interface
ORing Industrial Networking Corp 20
IES-3073GC User’s Manual
The following table describes the labels in this screen.
Label Description
DHCP Client To enable or disable the DHCP client function. When DHCP
client function is enabling, the switch will be assigned the IP
address from the network DHCP server. The default IP address
will be replaced by the IP address which the DHCP server has
assigned. After clicking “Apply” button, a popup dialog shows
up to inform when the DHCP client is enabling. The current IP
will lose and you should find a new IP on the DHCP server.
IP Address Assign the IP address that the network is using. If DHCP client
function is enabling, you do not need to assign the IP address.
The network DHCP server will assign the IP address for the
switch and it will be display in this column. The default IP is
192.168.10.1
Subnet Mask Assign the subnet mask of the IP address. If DHCP client
function is enabling, you do not need to assign the subnet mask
Gateway Assign the network gateway for the switch. The default gateway
is 192.168.10.254
DNS1 Assign the primary DNS IP address
DNS2 Assign the secondary DNS IP address
Apply Click “Apply” to activate the configurations.
5.1.4.4 SNTP (Time)
The SNTP (Simple Network Time Protocol) settings allow you to synchronize switch clocks
in the Internet.
ORing Industrial Networking Corp 21
IES-3073GC User’s Manual
SNTP Configuration interface
The following table describes the labels in this screen.
Label Description
SNTP Client Enable or disable SNTP function to get the time from the SNTP
server.
Daylight Saving Time Enable or disable daylight saving time function. When daylight
saving time is enabling, you need to configure the daylight saving
time period.
UTC Time zone Set the switch location time zone. The following table lists the
different location time zone for your reference.
Local Time Zone Conversion from UTC Time at 12:00 UTC
November Time Zone - 1 hour 11 am
Oscar Time Zone -2 hours 10 am
ADT - Atlantic Daylight -3 hours 9 am
AST - Atlantic Standard
-4 hours 8 am
EDT - Eastern Daylight
EST - Eastern Standard
-5 hours 7 am
CDT - Central Daylight
CST - Central Standard
-6 hours 6 am
MDT - Mountain Daylight
MST - Mountain Standard
-7 hours 5 am
PDT - Pacific Daylight
PST - Pacific Standard
-8 hours 4 am
ADT - Alaskan Daylight
ALA - Alaskan Standard -9 hours 3 am
HAW - Hawaiian Standard -10 hours 2 am
Nome, Alaska -11 hours 1 am
ORing Industrial Networking Corp 22
IES-3073GC User’s Manual
CET - Central European
FWT - French Winter
MET - Middle European
+1 hour 1 pm
MEWT - Middle European
Winter
SWT - Swedish Winter
EET - Eastern European,
+2 hours 2 pm
USSR Zone 1
BT - Baghdad, USSR Zone
+3 hours 3 pm
2
ZP4 - USSR Zone 3 +4 hours 4 pm
ZP5 - USSR Zone 4 +5 hours 5 pm
ZP6 - USSR Zone 5 +6 hours 6 pm
WAST - West Australian
+7 hours 7 pm
Standard
CCT - China Coast, USSR
+8 hours 8 pm
Zone 7
JST - Japan Standard,
+9 hours 9 pm
USSR Zone 8
EAST - East Australian
Standard GST
+10 hours 10 pm
Guam Standard, USSR
Zone 9
IDLE - International Date
Line
NZST - New Zealand +12 hours Midnight
Standard
NZT - New Zealand
Label Description
SNTP Sever IP
Set the SNTP server IP address.
Address
Daylight Saving Set up the Daylight Saving beginning time and Daylight Saving
ORing Industrial Networking Corp 23
IES-3073GC User’s Manual
Period ending time. Both will be different each year.
Daylight Saving
Set up the offset time.
Offset
Switch Timer Display the switch current time.
Apply Click “Apply” to activate the configurations.
5.1.4.5 LLDP
LLDP (Link Layer Discovery Protocol) function allows the switch to advertise its information
to other nodes on the network and store the information it discovers.
LLDP configuration interface
The following table describes the labels in this screen.
Label Description
LLDP Protocol “Enable” or “Disable” LLDP function.
LLDP Interval The interval of resend LLDP (by default at 30 seconds)
Apply Click “Apply” to activate the configurations.
Help Show help file.
5.1.4.6 Auto Provision
Auto Provision allows you to update the switch firmware automatically. You can put
firmware or configuration file on TFTP server. When you reboot the switch, it will upgrade
automatically. Before updating, make sure you have your TFTP server ready and the
firmware image and configuration file is on the TFTP server.
Auto Provision interface
ORing Industrial Networking Corp 24
IES-3073GC User’s Manual
5.1.4.7 Backup & Restore
You can save current configuration from the switch to TFTP server, or restore the
configuration from TFTP server in this page.
Backup & Restore interface
The following table describes the labels in this screen.
Label Description
TFTP Server IP Fill in the TFTP server IP
Address
Restore File Name Fill the file name.
Restore Click “restore” to restore the configurations.
Restore File Name Fill the file name.
Restore Click “restore” to restore the configurations.
Backup Click “backup” to backup the configurations.
5.1.4.8 Upgrade Firmware
Upgrade Firmware allows you to update the firmware of switch. Before updating, make
sure you have your TFTP server ready and the firmware image is on the TFTP server.
ORing Industrial Networking Corp 25
IES-3073GC User’s Manual
Update Firmware interface
5.1.5 DHCP Server
5.1.5.1 DHCP Server – Setting
The system provides with DHCP server function. Enable the DHCP server function, the
switch system will be a DHCP server.
DHCP Server Configuration interface
The following table describes the labels in this screen.
Label Description
DHCP Server Enable or Disable the DHCP Server function. Enable – the
switch will be the DHCP server on your local network
Start IP Address The dynamic IP assign range. Low IP address is the beginning
of the dynamic IP assigns range. For example: dynamic IP
assign range is from 192.168.1.100 to 192.168.1.200.
192.168.1.100 will be the Start IP address.
End IP Address The dynamic IP assign range. High IP address is the end of the
ORing Industrial Networking Corp 26
IES-3073GC User’s Manual
dynamic IP assigns range. For example: dynamic IP assign
range is from 192.168.1.100 to 192.168.1.200. 192.168.1.200
will be the End IP address
Subnet Mask The dynamic IP assign range subnet mask
Gateway The gateway in your network.
DNS Domain Name Server IP Address in your network.
It is the period that system will reset the assigned dynamic IP to
Lease Time (Hour)
ensure the IP address is in used.
Apply Click “Apply” to activate the configurations.
5.1.5.2 DHCP Server – Client List
When the DHCP server function is activated, the system will collect the DHCP client
information and display in here.
DHCP Server Client Entries interface
5.1.5.3 DHCP Server – Port and IP bindings
You can assign the specific IP address which is in the assigned dynamic IP range to the
specific port. When the device is connecting to the port and asks for dynamic IP assigning,
the system will assign the IP address that has been assigned before in the connected device.
DHCP Server Port and IP Binding interface
ORing Industrial Networking Corp 27
IES-3073GC User’s Manual
5.1.6 Port Setting
5.1.6.1 Port Control
By this function, you can set the state, speed/duplex, flow control, and security of the port.
Port Control interface
The following table describes the labels in this screen.
Label Description
Port NO. Port number for setting.
Speed/Duplex You can set Auto-negotiation, 100 full, 100 half, 10 full or 10 half
Flow Control Support symmetric and asymmetric mode to avoid packet loss
when congestion occurred.
Security Support port security function. When enable the function, the
port will STOP learning MAC address dynamically.
Apply Click “Apply” to activate the configurations.
5.1.6.2 Port Status
The following information provides the current port status information
ORing Industrial Networking Corp 28
IES-3073GC User’s Manual
Port Status interface
5.1.6.3 Port Alias
The user can define the name of every Port. Can let user, convenient management every Port.
ORing Industrial Networking Corp 29
IES-3073GC User’s Manual
5.1.6.4 Rate Limit
By this function, you can limit traffic of all ports, including broadcast, multicast and flooded
Unicast. You can also set “Ingress” or “Egress” to limit traffic received or transmitted
bandwidth.
Rate Limit interface
The following table describes the labels in this screen.
Label Description
Ingress Limit Frame You can set “all”, “Broadcast only”, ”Broadcast/Multicast”
Type or ”Broadcast/Multicast/Flooded Unicast” mode.
Ingress The switch port received traffic.
Egress The switch port transmitted traffic.
Apply Click “Apply” to activate the configurations.
ORing Industrial Networking Corp 30
IES-3073GC User’s Manual
5.1.6.5 Port Trunk
Port Trunk – Setting
You can select static trunk or 802.3ad LACP to combine several physical links with a logical
link to increase the bandwidth.
Port Trunk - Setting interface
The following table describes the labels in this screen.
Label Description
Group ID Select port to join a trunk group.
Type Support static trunk and 802.3ad LACP
Apply Click “Apply” to activate the configurations.
ORing Industrial Networking Corp 31
IES-3073GC User’s Manual
Port Trunk – LACP
With LLDP Protocol, the user can define port that want to work to count by oneself
Label Description
Work Ports Work ports counted (max:4 ports)
Apply Click “Apply” to activate the configurations.
Port Trunk – Status
You can check the configuration of port trunk.
Port Trunk - Status interface
ORing Industrial Networking Corp 32
IES-3073GC User’s Manual
5.1.7 Redundancy
5.1.7.1 O-Ring
O-Ring is one of the most powerful redundant ring technologies in the world. The recovery
time of O-Ring is less than 10 ms over 250 units of connections. It can reduce unexpected
malfunction caused by network topology change. O-Ring technology supports three Ring
topologies for network redundancy: O-Ring, Coupling Ring and Dual Homing.
O-Ring interface
The following table describes the labels in this screen.
Label Description
O-Ring To enable O-Ring.
Ring Master There should be one and only one Ring Master in a ring.
However if there are two or more switches which set Ring Master
to enable, the switch with the lowest MAC address will be the
actual Ring Master and others will be Backup Masters.
st
1 Ring Port The primary port, when this switch is configured in O-Ring.
nd
2 Ring Port The backup port, when this switch is configured in O-Ring.
Coupling Ring To enable Coupling Ring. Coupling Ring can be used to divide a
big ring into two smaller Rings to avoid effecting all switches when
network topology change. It is a good application for connecting
two Rings.
Coupling Port Set a port as coupling port to link to the Coupling Port of the
switch in another ring. Coupling Ring need four switch to
construct an active and a backup link. The coupled four ports of
four switches will be operated at active/backup mode.
Dual Homing To enable Dual Homing. By selecting Dual Homing mode, Ring
ORing Industrial Networking Corp 33
IES-3073GC User’s Manual
will be connected to normal switches through two RSTP links (i.e.,
backbone Switch). The two links act as active/backup mode,
and connect each Ring to the normal switches in RSTP mode.
Apply Click “Apply” to activate the configurations.
Note: It is not recommended to set one switch as a Ring Master and a Coupling Ring at the same time due to
heavy load of system.
5.1.7.2 Open-Ring
Open-Ring technology can be applied for other vendor’s proprietary ring. Thus, you can
add switches of ORing into the network constructed by other ring technology and enable
Open-Ring to co-operate with other vendor’s managed switch.
Click ”Connect to other vendor’s ring…..” to join the ring constructed by other vendor.
Open-Ring interface
Label Description
Enable Enabling the Open-Ring function
Vender Choosing the venders that you want to join to their ring
st
1 Ring Port Choosing the port which connect to the ring
2nd Ring Port Choosing the port which connect to the ring
ORing Industrial Networking Corp 34
IES-3073GC User’s Manual
The application of Open-Ring is shown as below.
Open-Ring connection
5.1.7.3 O-RSTP
O-RSTP is proprietary redundant ring technology invented by ORing. Different from
standard STP/RSTP, the recovery time of O-RSTP is less than 20ms and support more nodes
of connection in a ring topology.
ORing Industrial Networking Corp 35
IES-3073GC User’s Manual
O-RSTP interface
The application of O-RSTP is shown as below.
O-RSTP connection
5.1.7.4 RSTP
The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol
(STP). It provides faster convergence of spanning tree after a topology change. The
ORing Industrial Networking Corp 36
IES-3073GC User’s Manual
system also supports STP and the system will detect the connected device that is running STP
or RSTP protocol automatically.
RSTP setting
You can enable/disable RSTP function, and set parameters for each port.
RSTP Setting interface
ORing Industrial Networking Corp 37
IES-3073GC User’s Manual
The following table describes the labels in this screen.
Label Description
RSTP mode You must enable or disable RSTP function before configuring the
related parameters.
Priority (0-61440) A value used to identify the root bridge. The bridge with the
lowest value with the highest priority and is selected as the root.
If the value changes, you must restart the switch. The value
must be multiple of 4096 according to the rule of the protocol.
Max Age (6-40) The number of seconds for a bridge to wait without receiving
Spanning-tree Protocol configuration messages before
reconfiguration. Enter a value between 6 through 40.
Hello Time (1-10) The time that controls switch sends out the BPDU (Bridge
Protocol Data Unit) packet to check RSTP current status. Enter
a value between 1 through 10.
Forwarding Delay The number of seconds a port to wait before changing from its
Time (4-30) learning/listening state to forwarding state. Enter a value
between 4 through 30.
Path Cost The cost of the path to the other bridge from this transmitting
(1-200000000) bridge at the specified port. Enter a number 1 through
200000000.
Priority (0-240) Decide which port should be blocked by setting the priority in
LAN. Enter a number 0 through 240. The value of priority must
be the multiple of 16
Admin P2P Some of the rapid state transactions that are possible within
RSTP are dependent upon whether the port concerned can only
be connected to exactly one other bridge (i.e., It is served by a
point-to-point LAN segment), or it can be connected to two or
more bridges (i.e., It is served by a shared medium LAN
segment). This function allows the P2P status of the link to be
manipulated administratively. True means P2P enabled. False
means P2P disabled.
Admin Edge The port directly connected to end stations, and it cannot create
bridging loop in the network. To configure the port as an edge
port, set the port to “True”.
Admin Non STP The port includes the STP mathematic calculation. STP
algorithm is included for “True“ setting, STP algorithm is not
included for “False“ setting.
ORing Industrial Networking Corp 38
IES-3073GC User’s Manual
Apply Click “Apply” to activate the configurations.
NOTE: Follow the rule to configure the MAX Age, Hello Time, and Forward Delay Time:
2 x (Forward Delay Time value –1) ≥ Max Age value ≥ 2 x (Hello Time value +1)
RSTP Information
Show RSTP algorithm result at this table.
RSTP Information interface
5.1.7.5 MSTP
Multiple Spanning Tree Protocol (MSTP) is a standard protocol base on IEEE 802.1s. The
function is that several VLANs can be mapping to a reduced number of spanning tree
instances because most networks do not need more than a few logical topologies. It supports
load balancing scheme and the CPU is sparer than PVST (Cisco proprietary technology).
ORing Industrial Networking Corp 39
IES-3073GC User’s Manual
MSTP Setting interface
The following table describes the labels in this screen.
Label Description
MSTP Enable You must enable or disable MSTP function before configuring the
related parameters.
Force Version The Force Version parameter can be used to force a VLAN Bridge
that supports RSTP to operate in an STP-compatible manner.
Configuration Name The same MST Region must have the same MST configuration
name.
Revision Level The same MST Region must have the same revision level.
(0-65535)
Priority (0-61440) A value used to identify the root bridge. The bridge with the
lowest value has the highest priority and is selected as the root.
If the value changes, You must reboot the switch. The value
must be multiple of 4096 according to the protocol standard rule.
Max Age Time(6-40) The number of seconds a bridge waits without receiving
Spanning-tree Protocol configuration messages before attempting
a reconfiguration. Enter a value between 6 through 40.
Hello Time (1-10) The setting follow the rule below to configure the MAX Age, Hello
ORing Industrial Networking Corp 40
IES-3073GC User’s Manual
Time, and Forward Delay Time at controlled switch sends out the
BPDU packet to check RSTP current status. Enter a value
between 1 through 10.
2 x (Forward Delay Time value –1) ≥ Max Age value ≥ 2 x (Hello Time value
+1)
Forwarding Delay The number of seconds a port waits before changing from its
Time (4-30) Rapid Spanning-Tree Protocol learning and listening states to the
forwarding state. Enter a value between 4 through 30.
Max Hops (1-40) This parameter is additional to those specified for RSTP. A single
value applies to all Spanning Trees within an MST Region (the
CIST and all MSTIs) for which the Bridge is the Regional Root.
Apply Click “Apply” to activate the configurations.
MSTP Port interface
Label Description
Port No. Selecting the port that you want to configure.
Priority (0-240) Decide which port should be blocked by priority in LAN. Enter a
number 0 through 240. The value of priority must be the multiple
of 16
Path Cost The cost of the path to the other bridge from this transmitting
(1-200000000) bridge at the specified port. Enter a number 1 through
200000000.
Admin P2P Some of the rapid state transactions that are possible within
RSTP are dependent upon whether the port concerned can only
be connected to exactly one other bridge (i.e. It is served by a
ORing Industrial Networking Corp 41
IES-3073GC User’s Manual
point-to-point LAN segment), or it can be connected to two or
more bridges (i.e. It is served by a shared medium LAN segment).
This function allows the P2P status of the link to be manipulated
administratively. True means P2P enabling. False means P2P
disabling.
Admin Edge Label
Admin Non STP Label
Apply Click “Apply” to activate the configurations.
MSTP Instance interface
Label Description
Instance Set the instance from 1 to 15
State Enable or disable the instance
VLANs Set which VLAN will belong which instance
Proprietary (0-61440) A value used to identify the root bridge. The bridge with the
lowest value has the highest priority and is selected as the root.
If the value changes, You must reboot the switch. The value
must be multiple of 4096 according to the protocol standard rule.
Apply Click “Apply” to activate the configurations.
ORing Industrial Networking Corp 42
IES-3073GC User’s Manual
MSTP Instance Port interface
Label Description
Instance Set the instance’s information except CIST
Port Selecting the port that you want to configure.
Priority (0-240) Decide which port should be blocked by priority in LAN. Enter a
number 0 through 240. The value of priority must be the multiple
of 16
Path Cost The cost of the path to the other bridge from this transmitting
(1-200000000) bridge at the specified port. Enter a number 1 through
200000000.
Apply Click “Apply” to set the configurations.
5.1.8 VLAN
A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain, which
allows you to isolate network traffic. Only the members of the same VLAN will receive the
traffic from the other members. Basically, to create a VLAN from a switch is logically
equivalent of separating a group of network devices. However, all the network devices are
still plugged into the same switch physically.
This managed switch supports port-based and 802.1Q (tagged-based) VLAN. The default
configuration of VLAN operation mode is at “802.1Q”.
5.1.8.1 VLAN Setting
Tagged-based VLAN is an IEEE 802.1Q specification standard, and t is possible to create a
VLAN across devices from different switch venders. IEEE 802.1Q VLAN uses a technique to
ORing Industrial Networking Corp 43
IES-3073GC User’s Manual
insert a “tag” into the Ethernet frames. Tag contains a VLAN Identifier (VID) that indicates the
VLAN numbers.
You can create Tag-based VLAN, and enable or disable GVRP protocol. There are 256
VLAN groups available. Enable 802.1Q VLAN, all ports on the switch belong to default VLAN,
VID is 1. The default VLAN cannot be deleted.
GVRP allows automatic VLAN configuration between the switch and nodes. If the switch is
connected to a device with GVRP enabled, you can send a GVRP request by using the VID of
a VLAN defined on the switch; the switch will automatically add that device to the existing
VLAN.
VLAN Configuration – 802.1Q interface
ORing Industrial Networking Corp 44
IES-3073GC User’s Manual
The following table describes the labels in this screen.
Label Description
VLAN Operation Configure VLAN Operation Mode: disable, Port Base,802.1Q
Mode
GVRP Mode Enable/Disable GVRP function.
Management VLAN Management VLAN provide network administrator a secured
ID VLAN to management Switch. Only the devices in the
management VLAN can access the switch.
Link type There are 3 types of link type:
Access Link: single switch only, allows you to group ports by
setting the same VID.
Trunk Link: extended application of Access Link, allows you to
group ports by setting the same VID with 2 or more switches.
Hybrid Link: Both Access Link and Trunk Link are available.
Hybrid(QinQ) Link: enable QinQ mode,allow you to insert one
more VLAN tag in a original VLAN frame.
Untagged VID Set the port default VLAN ID for untagged devices that connect to
the port. The range is 1 to 4094.
Tagged VIDs Set the tagged VIDs to carry different VLAN frames to other
switch.
Apply Click “Apply” to activate the configurations.
5.1.8.2 VLAN Setting – Port Based
Traffic is forwarded to the member ports of the same vlan group. vlan port based startup, set in
the same group of the port, can be a normal transmission packet, without restricting the types
of packets.
VLAN Configuration – Port Base interface-1
ORing Industrial Networking Corp 45
IES-3073GC User’s Manual
The following table describes the labels in this screen.
Label Description
Add Click “add” to enter VLAN add interface.
Edit Edit exist VLAN
Delete Delete exist VLAN
Help Show help file.
VLAN Configuration – Port Base interface-2
The following table describes the labels in this screen.
Label Description
Group Name VLAN name.
VLAN ID Specify the VLAN ID
Add Select port to join the VLAN group.
Remove Remove port of the VLAN group
Apply Click “Apply” to activate the configurations.
Help Show help file.
ORing Industrial Networking Corp 46
IES-3073GC User’s Manual
5.1.9 SNMP
Simple Network Management Protocol (SNMP) is the protocol developed to manage nodes
(servers, workstations, routers, switches and hubs etc.) on an IP network. SNMP enables
network administrators to manage network performance, find and solve network problems, and
plan for network growth. Network management systems learn of problems by receiving traps
or change notices from network devices implementing SNMP.
5.1.9.1 SNMP – Agent Setting
You can set SNMP agent related information by Agent Setting Function.
SNMP Agent Setting interface
The following table describes the labels in this screen.
Label Description
SNMP agent Version Three SNMP versions are supported such as SNMP V1/SNMP
V2c, and SNMP V3. SNMP V1/SNMP V2c agent use a
community string match for authentication, that means SNMP
ORing Industrial Networking Corp 47
IES-3073GC User’s Manual
servers access objects with read-only or read/write permissions
with the community default string public/private. SNMP V3
requires an authentication level of MD5 or DES to encrypt data to
enhance data security.
SNMP V1/V2c SNMP Community should be set for SNMP V1/V2c. Four sets of
Community "Community String/Privilege" are supported. Each Community
String is maximum 32 characters. Keep empty to remove this
Community string.
SNMPv3User If SNMP V3 agent is selected, the SNMPv3 you profiled should be
set for authentication. The Username is necessary. The Auth
Password is encrypted by MD5 and the Privacy Password which
is encrypted by DES. There are maximum 8 sets of SNMPv3
User and maximum 16 characters in username, and password.
When SNMP V3 agent is selected, you can:
1. Input SNMPv3 username only.
2. Input SNMPv3 username and Auth Password.
3. Input SNMPv3 username, Auth Password and
Privacy Password, which can be different with
Auth Password.
To remove a current user profile:
1. Input SNMPv3 user name you want to remove.
2. Click "Remove" button
Current SNMPv3 Show all SNMPv3 user profiles.
User Profile
Apply Click “Apply” to activate the configurations.
Help Show help file.
5.1.9.2 SNMP – Trap Setting
A trap manager is a management station that receives traps, the system alerts generated by
the switch. If no trap manager is defined, no traps will issue. Create a trap manager by
entering the IP address of the station and a community string. To define management
stations as trap manager and enter SNMP community strings and selects the SNMP version.
ORing Industrial Networking Corp 48
IES-3073GC User’s Manual
SNMP Trap Setting interface
The following table describes the labels in this screen.
Label Description
Server IP The server IP address to receive Trap
Community Community for authentication
Trap Version Trap Version supports V1 and V2c.
Add Add trap server profile.
Remove Remove trap server profile.
Help Show help file.
5.1.10 Traffic Prioritization
Traffic Prioritization includes 3 modes: port base, 802.1p/COS, and TOS/DSCP. By traffic
prioritization function, you can classify the traffic into four classes for differential network
application. IES-3073GC support 4 priority queues.
Polocy Setting interface
ORing Industrial Networking Corp 49
IES-3073GC User’s Manual
Label Description
QoS Mode Port-base: the output priority is determined by ingress port.
COS only: the output priority is determined by COS only.
TOS only: the output priority is determined by TOS only.
COS first: the output priority is determined by COS and
TOS, but COS first.
TOS first: the output priority is determined by COS and
TOS, but TOS first.
QoS policy Using the 8,4,2,1 weight fair queue scheme: the output
queues will follow 8:4:2:1 ratio to transmit packets from the
highest to lowest queue. For example: 8 high queue
packets, 4 middle queue packets, 2 low queue packets, and
the one lowest queue packets are transmitted in one turn.
Use the strict priority scheme: always the packets in
higher queue will be transmitted first until higher queue is
empty.
Help Show help file.
Apply Click “Apply” to activate the configurations.
Port-based Priority interface
ORing Industrial Networking Corp 50
IES-3073GC User’s Manual
Label Description
Port base Priority Assign Port with a priority queue. 4 priority queues can be
assigned: High, Middle, Low, and Lowest.
Help Show help file.
Apply Click “Apply” to activate the configurations.
COS/802.1p interface
ORing Industrial Networking Corp 51
IES-3073GC User’s Manual
Label Description
COS/802.1p COS (Class Of Service) is well known as 802.1p. It describes
that the output priority of a packet is determined by user priority
field in 802.1Q VLAN tag. The priority value is supported
0to7.COS value map to 4 priority queues: High, Middle, Low, and
Lowest.
COS Port Default When an ingress packet has not VLAN tag, a default priority value
is considered and determined by ingress port.
Help Show help file.
Apply Click “Apply” to activate the configurations.
TOS/DSCP interface
Label Description
TOS/DSCP TOS (Type of Service) is a field in IP header of a packet. This
TOS field is also used by Differentiated Services and is called the
Differentiated Services Code Point (DSCP). The output priority
of a packet can be determined by this field and the priority value is
supported 0 to 63. DSCP value map to 4 priority queues: High,
Middle, Low, and Lowest.
Apply Click “Apply” to activate the configurations.
Help Show help file.
ORing Industrial Networking Corp 52
IES-3073GC User’s Manual
5.1.11 Multicast
5.1.11.1 IGMP Snooping
Internet Group Management Protocol (IGMP) is used by IP hosts to register their dynamic
multicast group membership. IGMP has 3 versions, IGMP v1, v2 and v3. Please refer to
RFC 1112, 2236 and 3376. IGMP Snooping improves the performance of networks that
carry multicast traffic. It provides the ability to prune multicast traffic so that it travels only to
those end destinations that require that traffic and reduces the amount of traffic on the
Ethernet LAN.
IGMP Snooping interface
The following table describes the labels in this screen.
Label Description
IGMP Snooping Enable/Disable IGMP snooping.
IGMP Query Mode Switch will be IGMP querier or not. There should exist one and
the only one IGMP querier in an IGMP application. The "Auto"
mode means that the querier is the one with lower IP address.
IGMP Snooping Table Show current IP multicast list
Apply Click “Apply” to activate the configurations.
Help Show help file.
ORing Industrial Networking Corp 53
IES-3073GC User’s Manual
5.1.11.2 MVR
MVR Function can provide a different VLAN users to receive MVR Mode VLAN Multicast
Packet.
Label Description
MVR Mode Enable or Disable MVR Mode
MVR VLAN Setting MVR VLAN
TYPE Setting Port Type to inactive、Receiver、Source
Immediate Leave Enable or disable Immediate leave
ORing Industrial Networking Corp 54
IES-3073GC User’s Manual
5.1.11.3 Multicast Filter
Multicast filtering is the system by which end stations only receive multicast traffic if they
register to join specific multicast groups. With multicast filtering, network devices only forward
multicast traffic to the ports that are connected to registered end stations.
Multicast Filtering interface
The following table describes the labels in this screen.
Label Description
IP Address Assign a multicast group IP address in the range of 224.0.0.0 ~
239.255.255.255
Member Ports Tick the check box beside the port number to include them as the
member ports in the specific multicast group IP address.
Add Show current IP multicast list
Delete Delete an entry from table
Help Show help file.
ORing Industrial Networking Corp 55
IES-3073GC User’s Manual
5.1.12 Security
Five useful functions can enhance security of switch: IP Security, Port Security, MAC Blacklist,
and MAC address Aging and 802.1x protocol.
5.1.12.1 IP Security
IP security can enable/disable remote management from WEB or Telnet or SNMP. Additionally,
IP security can restrict remote management to some specific IP addresses. Only these secure
IP addresses can manage this switch remotely.
IP Security interface
The following table describes the labels in this screen.
Label Description
IP security MODE Enable/Disable the IP security function.
Enable WEB Mark the blank to enable WEB Management.
Management
ORing Industrial Networking Corp 56
IES-3073GC User’s Manual
Enable Telnet Mark the blank to enable Telnet Management.
Management
Enable SNMP Mark the blank to enable SNMP Management.
Management
Apply Click “Apply” to activate the configurations.
Help Show help file.
5.1.12.2 Port Security
Port security is to add static MAC addresses to hardware forwarding database. If port
security is enabled at Port Control page, only the frames with MAC addresses in this list will
be forwarded, otherwise will be discarded.
Port Security interface
The following table describes the labels in this screen.
Label Description
MAC Address Input MAC Address to a specific port.
Port NO. Select port of switch.
Add Add an entry of MAC and port information.
Delete Delete the entry.
Help Show help file.
ORing Industrial Networking Corp 57
IES-3073GC User’s Manual
5.1.12.3 MAC Blacklist
MAC Blacklist can eliminate the traffic forwarding to specific MAC addresses in list. Any
frames forwarding to MAC addresses in this list will be discarded. Thus the target device will
never receive any frame.
MAC Blacklist interface
The following table describes the labels in this screen.
Label Description
MAC Address Input MAC Address to add to MAC Blacklist.
Port NO. Select port of switch.
Add Add an entry to Blacklist table.
Delete Delete the entry.
Help Show help file.
5.1.12.4 802.1x
802.1x - Radius Server
802.1x makes the use of the physical access characteristics of IEEE802 LAN infrastructures
in order to provide a authenticated and authorized devices attached to a LAN port. Please
refer to IEEE 802.1X - Port Based Network Access Control.
ORing Industrial Networking Corp 58
IES-3073GC User’s Manual
802.1x Radius Server interface
The following table describes the labels in this screen.
Label Description
Radius Server Setting
Radius Server IP The IP address of the authentication server.
Server port Set the UDP port number used by the authentication server to
authenticate.
Account port Set the UDP destination port for accounting requests to the
specified Radius Server.
Shared Key A key shared between this switch and authentication server.
NAS, Identifier A string used to identify this switch.
Advanced Setting
Quiet Period Set the time interval between authentication failure and the start
of a new authentication attempt.
Tx Period Set the time that the switch can wait for response to an EAP
request/identity frame from the client before resending the
request.
ORing Industrial Networking Corp 59
IES-3073GC User’s Manual
Supplicant Timeout Set the period of time the switch waits for a supplicant response
to an EAP request.
Server Timeout Set the period of time the switch waits for a Radius server
response to an authentication request.
Max Requests Set the maximum number of times to retry sending packets to the
supplicant.
Re-Auth Period Set the period of time after which clients connected must be
re-authenticated.
Apply Click “Apply” to activate the configurations.
Help Show help file.
802.1x-Port Authorized Mode
Set the 802.1x authorized mode of each port.
802.1x Port Authorize interface
The following table describes the labels in this screen.
Label Description
Port Authorized Reject: force this port to be unauthorized.
Mode Accept: force this port to be authorized.
Authorize: the state of this port was determined by the
outcome of the 802.1x authentication.
Disable: this port will not participate in 802.1x.
ORing Industrial Networking Corp 60
IES-3073GC User’s Manual
Apply Click “Apply” to activate the configurations.
Help Show help file.
802.1x-Port Authorized State
Show 802.1x port authorized state.
802.1x Port Authorize State interface
5.1.13 Warning
Warning function is very important for managing switch. You can manage switch by
SYSLOG, E-MAIL, and Fault Relay. It helps you to monitor the switch status on remote site.
When events occurred, the warning message will send to your appointed server, E-MAIL, or
relay fault to switch panel.
5.1.13.1 Fault Alarm
When any selected fault event is happened, the Fault LED in switch panel will light up and
the electric relay will signal at the same time.
Fault Alarm interface
ORing Industrial Networking Corp 61
IES-3073GC User’s Manual
The following table describes the labels in this screen.
Label Description
Power Failure Mark the blank of PWR 1 or PWR 2 to monitor.
Port Link Mark the blank of port 1 to port 10 to monitor.
Down/Broken
Apply Click “Apply” to activate the configurations.
Help Show help file.
5.1.13.2 System Alarm
System alarm support two warning mode: 1. SYSLOG. 2. E-MAIL. You can monitor
switch through selected system events.
System Warning – SYSLOG Setting
The SYSLOG is a protocol to transmit event notification messages across networks.
Please refer to RFC 3164 - The BSD SYSLOG Protocol
System Warning – SYSLOG Setting interface
The following table describes the labels in this screen.
Label Description
SYSLOG Mode Disable: disable SYSLOG.
Client Only: log to local system.
Server Only: log to a remote SYSLOG server.
Both: log to both of local and remote server.
SYSLOG Server IP The remote SYSLOG Server IP address.
Address
Apply Click “Apply” to activate the configurations.
Help Show help file.
ORing Industrial Networking Corp 62
IES-3073GC User’s Manual
System Warning – SMTP Setting
The SMTP is Short for Simple Mail Transfer Protocol. It is a protocol for e-mail
transmission across the Internet. Please refer to RFC 821 - Simple Mail Transfer Protocol.
System Warning – SMTP Setting interface
The following table describes the labels in this screen.
Label Description
E-mail Alarm Enable/Disable transmission system warning events by e-mail.
Sender E-mail The SMTP server IP address
Address
Mail Subject The Subject of the mail
Authentication Username: the authentication username.
Password: the authentication password.
Confirm Password: re-enter password.
Recipient E-mail The recipient's E-mail address. It supports 6 recipients for a
Address mail.
Apply Click “Apply” to activate the configurations.
Help Show help file.
ORing Industrial Networking Corp 63
IES-3073GC User’s Manual
System Warning – Event Selection
SYSLOG and SMTP are the two warning methods that supported by the system. Check
the corresponding box to enable system event warning method you wish to choose. Please
note that the checkbox can not be checked when SYSLOG or SMTP is disabled.
System Warning – Event Selection interface
The following table describes the labels in this screen.
Label Description
System Event
System Cold Start Alert when system restart
Power Status Alert when a power up or down
SNMP Authentication Alert when SNMP authentication failure.
Failure
O-Ring Topology Alert when O-Ring topology changes.
Change
ORing Industrial Networking Corp 64
IES-3073GC User’s Manual
Port Event Disable
SYSLOG / SMTP Link Up
event Link Down
Link Up & Link Down
Apply Click “Apply” to activate the configurations.
Help Show help file.
5.1.14 Monitor and Diag
5.1.14.1 MAC Address Table
Refer to IEEE 802.1 D Sections 7.9. The MAC Address Table, that is Filtering Database,
supports queries by the Forwarding Process, as to whether a frame received by a given port
with a given destination MAC address is to be forwarded through a given potential
transmission port.
MAC Address Table interface
The following table describes the labels in this screen.
Label Description
Port NO. : Show all MAC addresses mapping to a selected port in table.
ORing Industrial Networking Corp 65
IES-3073GC User’s Manual
Clear MAC Table Clear all MAC addresses in table
Help Show help file.
5.1.14.2 MAC Address Aging
You can set MAC Address aging timer, as time expired, the unused MAC will be cleared
from MAC table. IES-3073GC also support Auto Flush MAC Address Table When ports Link
Down.
MAC Address Aging interface
The following table describes the labels in this screen.
Label Description
MAC Address Table Set the aging time for MAC table. The value is between 0 and
Aging Time 3825. Default setting is 300 secs.
Auto Flush MAC Enable this function,
Address Table When
ports Link Down
Apply Click “Apply” to activate the configurations.
Help Show help file.
5.1.14.3 Port Statistics
Port statistics show several statistics counters for all ports
ORing Industrial Networking Corp 66
IES-3073GC User’s Manual
Port Statistics interface
The following table describes the labels in this screen.
Label Description
Type Show port speed and media type.
Link Show port link status.
State Show ports enable or disable.
TX GOOD Packet The number of good packets sent by this port.
TX Bad Packet The number of bad packets sent by this port.
RX GOOD Packet The number of good packets received by this port.
RX Bad Packet The number of bad packets received by this port.
TX Abort Packet The number of packets aborted by this port.
Packet Collision The number of times a collision detected by this port.
Clear Clear all counters.
Help Show help file.
5.1.14.4 Port Monitoring
Port monitoring function supports TX (egress) only, RX (ingress) only, and both TX/RX
monitoring. TX monitoring sends any data that egress out checked TX source ports to a
selected TX destination port as well. RX monitoring sends any data that ingress in checked
RX source ports out to a selected RX destination port as well as sending the frame where it
normally would have gone. Note that keep all source ports unchecked in order to disable port
monitoring.
ORing Industrial Networking Corp 67
IES-3073GC User’s Manual
Port monitoring interface
The following table describes the labels in this screen.
Label Description
Destination Port The port will receive a copied frame from source port for
monitoring purpose.
Source Port The port will be monitored. Mark the blank of TX or RX to be
monitored.
TX The frames come into switch port.
RX The frames receive by switch port.
Apply Click “Apply” to activate the configurations.
Clear Clear all marked blank.(disable the function)
Help Show help file.
5.1.14.5 System Event Log
If system log client is enabled, the system event logs will be shown in this table.
ORing Industrial Networking Corp 68
IES-3073GC User’s Manual
System event log interface
The following table describes the labels in this screen.
Label Description
Page Select LOG page.
Reload To get the newest event logs and refresh this page.
Clear Clear log.
Help Show help file.
5.1.14.6 SFP Monitor
DDM function, can pass SFP module which supports DDM function, measure the temperature
of the apparatus .And manage and set up event alarm module through DDM WEB
ORing Industrial Networking Corp 69
IES-3073GC User’s Manual
Label Description
Warning Temperature Setting Warning Temperature
Event Alarm Select warning method(syslog or SMTP)
5.1.14.7 Ping
Ping function allows the switch to send ICMP packets to detect the remote notes.
Ping interface
The following table describes the labels in this screen.
Label Description
IP Address Enter the IP address that you want to detect.
Active Click “Active” to send ICMP packets
ORing Industrial Networking Corp 70
IES-3073GC User’s Manual
5.1.15 Save Configuration
If any configuration changed, “Save Configuration” should be clicked to save current
configuration data to the permanent flash memory. Otherwise, the current configuration will
be lost when power off or system reset.
System Configuration interface
The following table describes the labels in this screen.
Label Description
Save Save all configurations.
Help Show help file.
5.1.16 Factory Default
Factory Default interface
Reset switch to default configuration. Click Reset to reset all configurations to the
default value. You can select “Keep current IP address setting” and “Keep current
username & password” to keep current IP and username and password.
ORing Industrial Networking Corp 71
IES-3073GC User’s Manual
5.1.17 System Reboot
System Reboot interface
Command Line Interface Management
6.1 About CLI Management
Besides WEB-base management, IES-3073GC also support CLI management. You can
use console or telnet to management switch by CLI.
CLI Management by RS-232 Serial Console (9600, 8, none, 1, none)
Before Configuring by RS-232 serial console, use an RJ45 to DB9-F cable to connect the
Switches’ RS-232 Console port to your PC’s COM port.
Follow the steps below to access the console via RS-232 serial cable.
Step 1. From the Windows desktop, click on Start -> Programs -> Accessories ->
Communications -> Hyper Terminal
ORing Industrial Networking Corp 72
IES-3073GC User’s Manual
Step 2. Input a name for new connection
ORing Industrial Networking Corp 73
IES-3073GC User’s Manual
Step 3. Select to use COM port number
ORing Industrial Networking Corp 74
IES-3073GC User’s Manual
Step 4. The COM port properties setting, 9600 for Bits per second, 8 for Data bits, None for
Parity, 1 for Stop bits and none for Flow control.
Step 5. The Console login screen will appear. Use the keyboard to enter the Username and
Password (The same with the password for Web Browser), then press “Enter”.
ORing Industrial Networking Corp 75
IES-3073GC User’s Manual
CLI Management by Telnet
Users can use “TELNET” to configure the switches.
The default value is as below:
IP Address: 192.168.10.1
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.10.254
User Name: admin
Password: admin
Follow the steps below to access the console via Telnet.
Step 1. Telnet to the IP address of the switch from the Windows “Run“ command (or from the
MS-DOS prompt) as below.
Step 2. The Login screen will appear. Use the keyboard to enter the Username and
Password (The same with the password for Web Browser ), and then press “Enter”
ORing Industrial Networking Corp 76
IES-3073GC User’s Manual
Commands Level
Modes Access Method Prompt Exit Method About This Model
User EXEC Begin a session switch> Enter logout The user command
with your switch. or quit. available at the level of
user is the subset of
those available at the
privileged level.
Use this mode to
• Enter menu mode.
• Display system
information.
Privileged Enter the enable switch# Enter The privileged
EXEC command while in disable to command is advance
user EXEC mode. exit. mode
Privileged this mode to
• Display advance
function status
• save configures
Global Enter the configure switch(co To exit to Use this mode to
configuration command while in nfig)# privileged configure
privileged EXEC EXEC mode, parameters that apply
mode. enter exit or to your
end Switch as a whole.
VLAN Enter the vlan switch(vla To exit to Use this mode to
database database n)# user EXEC configure
command while in mode, enter VLAN-specific
privileged exit. parameters.
EXEC mode.
Interface Enter the interface switch(co To exit to Use this mode to
configuration command (with a nfig-if)# global configure
specific configuration parameters for the
interface)while in mode, switch and Ethernet
global configuration enter exit. ports.
mode To exist
privileged
EXEC mode
or end.
ORing Industrial Networking Corp 77
IES-3073GC User’s Manual
Symbol of Command Level.
Mode Symbol of Command Level
User EXEC E
Privileged EXEC P
Global configuration G
VLAN database V
Interface I
configuration
6.2 Commands Set List—System Commands Set
IES-3073GC Commands Level Description Example
show config E Show switch switch>show config
configuration
show terminal P Show console switch#show terminal
information
write memory P Save your switch#write memory
configuration into
permanent memory
(flash rom)
system name G Configure system switch(config)#system name xxx
[System Name] name
system location G Set switch system switch(config)#system location xxx
[System Location] location string
system description G Set switch system switch(config)#system description
[System Description] description string xxx
system contact G Set switch system switch(config)#system contact xxx
[System Contact] contact window string
show system-info E Show system switch>show system-info
information
ip address G Configure the IP switch(config)#ip address
[Ip-address] address of switch 192.168.1.1 255.255.255.0
[Subnet-mask] 192.168.1.254
[Gateway]
ip dhcp G Enable DHCP client switch(config)#ip dhcp
function of switch
ORing Industrial Networking Corp 78
IES-3073GC User’s Manual
show ip P Show IP information of switch#show ip
switch
no ip dhcp G Disable DHCP client switch(config)#no ip dhcp
function of switch
reload G Halt and perform a switch(config)#reload
cold restart
default G Restore to default Switch(config)#default
admin username G Changes a login switch(config)#admin username
[Username] username. xxxxxx
(maximum 10 words)
admin password G Specifies a password switch(config)#admin password
[Password] (maximum 10 words) xxxxxx
show admin P Show administrator switch#show admin
information
dhcpserver enable G Enable DHCP Server switch(config)#dhcpserver enable
dhcpserver lowip G Configure low IP switch(config)# dhcpserver lowip
[Low IP] address for IP pool 192.168.1.1
dhcpserver highip G Configure high IP switch(config)# dhcpserver highip
[High IP] address for IP pool 192.168.1.50
dhcpserver subnetmask G Configure subnet switch(config)#dhcpserver
[Subnet mask] mask for DHCP clients subnetmask 255.255.255.0
dhcpserver gateway G Configure gateway for switch(config)#dhcpserver gateway
[Gateway] DHCP clients 192.168.1.254
dhcpserver dnsip G Configure DNS IP for switch(config)# dhcpserver dnsip
[DNS IP] DHCP clients 192.168.1.1
dhcpserver leasetime G Configure lease time switch(config)#dhcpserver
[Hours] (in hour) leasetime 1
dhcpserver ipbinding I Set static IP for DHCP switch(config)#interface
[IP address] clients by port fastEthernet 2
switch(config-if)#dhcpserver
ipbinding 192.168.1.1
show dhcpserver P Show configuration of switch#show dhcpserver
configuration DHCP server configuration
show dhcpserver clients P Show client entries of switch#show dhcpserver clinets
DHCP server
show dhcpserver P Show IP-Binding switch#show dhcpserver ip-binding
ip-binding information of DHCP
ORing Industrial Networking Corp 79
IES-3073GC User’s Manual
server
no dhcpserver G Disable DHCP server switch(config)#no dhcpserver
function
security enable G Enable IP security switch(config)#security enable
function
security http G Enable IP security of switch(config)#security http
HTTP server
security telnet G Enable IP security of switch(config)#security telnet
telnet server
security ip G Set the IP security list switch(config)#security ip 1
[Index(1..10)] [IP 192.168.1.55
Address]
show security P Show the information switch#show security
of IP security
no security G Disable IP security switch(config)#no security
function
no security http G Disable IP security of switch(config)#no security http
HTTP server
no security telnet G Disable IP security of switch(config)#no security telnet
telnet server
6.3 Commands Set List—Port Commands Set
IES-3073GC Commands Level Description Example
interface fastEthernet G Choose the port for switch(config)#interface
[Portid] modification. fastEthernet 2
duplex I Use the duplex switch(config)#interface
[full | half] configuration fastEthernet 2
command to specify switch(config-if)#duplex full
the duplex mode of
operation for Fast
Ethernet.
speed I Use the speed switch(config)#interface
[10|100|1000|auto] configuration fastEthernet 2
command to specify switch(config-if)#speed 100
the speed mode of
operation for Fast
ORing Industrial Networking Corp 80
IES-3073GC User’s Manual
Ethernet., the speed
can’t be set to 1000 if
the port isn’t a giga
port..
flowcontrol mode I Use the flowcontrol switch(config)#interface
[Symmetric|Asymmetric] configuration fastEthernet 2
command on Ethernet switch(config-if)#flowcontrol mode
ports to control traffic Asymmetric
rates during
congestion.
no flowcontrol I Disable flow control of switch(config-if)#no flowcontrol
interface
security enable I Enable security of switch(config)#interface
interface fastEthernet 2
switch(config-if)#security enable
no security I Disable security of switch(config)#interface
interface fastEthernet 2
switch(config-if)#no security
bandwidth type all I Set interface ingress switch(config)#interface
limit frame type to fastEthernet 2
“accept all frame” switch(config-if)#bandwidth type all
bandwidth type I Set interface ingress switch(config)#interface
broadcast-multicast-floo limit frame type to fastEthernet 2
ded-unicast “accept broadcast, switch(config-if)#bandwidth type
multicast, and flooded broadcast-multicast-flooded-unicast
unicast frame”
bandwidth type I Set interface ingress switch(config)#interface
broadcast-multicast limit frame type to fastEthernet 2
“accept broadcast and switch(config-if)#bandwidth type
multicast frame” broadcast-multicast
bandwidth type I Set interface ingress switch(config)#interface
broadcast-only limit frame type to fastEthernet 2
“only accept switch(config-if)#bandwidth type
broadcast frame” broadcast-only
bandwidth in I Set interface input switch(config)#interface
[Value] bandwidth. Rate fastEthernet 2
Range is from 100 switch(config-if)#bandwidth in 100
ORing Industrial Networking Corp 81
IES-3073GC User’s Manual
kbps to 102400 kbps
or to 256000 kbps for
giga ports,
and zero means no
limit.
bandwidth out I Set interface output switch(config)#interface
[Value] bandwidth. Rate fastEthernet 2
Range is from 100 switch(config-if)#bandwidth out 100
kbps to 102400 kbps
or to 256000 kbps for
giga ports,
and zero means no
limit.
show bandwidth I Show interfaces switch(config)#interface
bandwidth control fastEthernet 2
switch(config-if)#show bandwidth
state I Use the state interface switch(config)#interface
[Enable | Disable] configuration fastEthernet 2
command to specify switch(config-if)#state Disable
the state mode of
operation for Ethernet
ports. Use the
disable form of this
command to disable
the port.
show interface I show interface switch(config)#interface
configuration configuration status fastEthernet 2
switch(config-if)#show interface
configuration
show interface status I show interface actual switch(config)#interface
status fastEthernet 2
switch(config-if)#show interface
status
show interface I show interface switch(config)#interface
accounting statistic counter fastEthernet 2
switch(config-if)#show interface
ORing Industrial Networking Corp 82
IES-3073GC User’s Manual
accounting
no accounting I Clear interface switch(config)#interface
accounting fastEthernet 2
information switch(config-if)#no accounting
6.4 Commands Set List—Trunk command set
IES-3073GC Commands Level Description Example
aggregator priority G Set port group system switch(config)#aggregator priority 22
[1to65535] priority
aggregator activityport G Set activity port switch(config)#aggregator
[Port Numbers] activityport 2
aggregator group G Assign a trunk group switch(config)#aggregator group 1
[GroupID] [Port-list] with LACP active. 1-4 lacp workp 2
lacp [GroupID] :1to3 or
workp [Port-list]:Member port switch(config)#aggregator group 2
[Workport] list, This parameter 1,4,3 lacp workp 3
could be a port
range(ex.1-4) or a port
list separate by a
comma(ex.2, 3, 6)
[Workport]: The
amount of work ports,
this value could not be
less than zero or be
large than the amount
of member ports.
aggregator group G Assign a static trunk switch(config)#aggregator group 1
[GroupID] [Port-list] group. 2-4 nolacp
nolacp [GroupID] :1to3 or
[Port-list]:Member port switch(config)#aggreator group 1
list, This parameter 3,1,2 nolacp
could be a port
range(ex.1-4) or a port
list separate by a
comma(ex.2, 3, 6)
ORing Industrial Networking Corp 83
IES-3073GC User’s Manual
show aggregator P Show the information switch#show aggregator
of trunk group
no aggregator lacp G Disable the LACP switch(config)#no aggreator lacp 1
[GroupID] function of trunk group
no aggregator group G Remove a trunk group switch(config)#no aggreator group 2
[GroupID]
6.5 Commands Set List—VLAN command set
IES-3073GC Commands Level Description Example
vlan database P Enter VLAN configure switch#vlan database
mode
vlan V To set switch VLAN switch(vlan)# vlanmode 802.1q
[8021q | gvrp] mode. or
switch(vlan)# vlanmode gvrp
no vlan V Disable vlan group(by switch(vlan)#no vlan 2
[VID] VID)
no gvrp V Disable GVRP switch(vlan)#no gvrp
IEEE 802.1Q VLAN
vlan 8021q port V Assign a access link switch(vlan)#vlan 802.1q port 3
[PortNumber] for VLAN by port, if the access-link untag 33
access-link untag port belong to a trunk
[UntaggedVID] group, this command
can’t be applied.
vlan 8021q port V Assign a trunk link for switch(vlan)#vlan 8021q port 3
[PortNumber] VLAN by port, if the trunk-link tag 2,3,6,99
trunk-link tag port belong to a trunk or
[TaggedVID List] group, this command switch(vlan)#vlan 8021q port 3
can’t be applied. trunk-link tag 3-20
vlan 8021q port V Assign a hybrid link for switch(vlan)# vlan 8021q port 3
[PortNumber] VLAN by port, if the hybrid-link untag 4 tag 3,6,8
hybrid-link untag port belong to a trunk or
[UntaggedVID] group, this command switch(vlan)# vlan 8021q port 3
tag can’t be applied. hybrid-link untag 5 tag 6-8
[TaggedVID List]
vlan 8021q aggreator V Assign a access link switch(vlan)#vlan 8021q aggreator 3
[TrunkID] for VLAN by trunk access-link untag 33
ORing Industrial Networking Corp 84
IES-3073GC User’s Manual
access-link untag group
[UntaggedVID]
vlan 8021q aggreator V Assign a trunk link for switch(vlan)#vlan 8021q aggreator 3
[TrunkID] VLAN by trunk group trunk-link tag 2,3,6,99
trunk-link tag or
[TaggedVID List] switch(vlan)#vlan 8021q aggreator 3
trunk-link tag 3-20
vlan 8021q aggreator V Assign a hybrid link for switch(vlan)# vlan 8021q aggreator 3
[PortNumber] VLAN by trunk group hybrid-link untag 4 tag 3,6,8
hybrid-link untag or
[UntaggedVID] switch(vlan)# vlan 8021q aggreator 3
tag hybrid-link untag 5 tag 6-8
[TaggedVID List]
show vlan [VID] V Show VLAN switch(vlan)#show vlan 23
or information
show vlan
6.6 Commands Set List—Spanning Tree command set
IES-3073GC Commands Level Description Example
spanning-tree enable G Enable spanning tree switch(config)#spanning-tree enable
spanning-tree priority G Configure spanning switch(config)#spanning-tree priority
[0to61440] tree priority parameter 32767
spanning-tree max-age G Use the spanning-tree switch(config)# spanning-tree
[seconds] max-age global max-age 15
configuration
command to change
the interval between
messages the
spanning tree
receives from the root
switch. If a switch
does not receive a
bridge protocol data
unit (BPDU) message
ORing Industrial Networking Corp 85
IES-3073GC User’s Manual
from the root switch
within this interval, it
recomputed the
Spanning Tree
Protocol (STP)
topology.
spanning-tree G Use the spanning-tree switch(config)#spanning-tree
hello-time [seconds] hello-time global hello-time 3
configuration
command to specify
the interval between
hello bridge protocol
data units (BPDUs).
spanning-tree G Use the spanning-tree switch(config)# spanning-tree
forward-time [seconds] forward-time global forward-time 20
configuration
command to set the
forwarding-time for the
specified
spanning-tree
instances. The
forwarding time
determines how long
each of the listening
and
learning states last
before the port begins
forwarding.
stp-path-cost I Use the spanning-tree switch(config)#interface fastEthernet
[1to200000000] cost interface 2
configuration switch(config-if)#stp-path-cost 20
command to set the
path cost for Spanning
Tree
Protocol (STP)
calculations. In the
event of a loop,
ORing Industrial Networking Corp 86
IES-3073GC User’s Manual
spanning tree
considers the path
cost when selecting
an interface to place
into the forwarding
state.
stp-path-priority I Use the spanning-tree switch(config)#interface fastEthernet
[Port Priority] port-priority interface 2
configuration switch(config-if)# stp-path-priority
command to configure 127
a port priority that
is used when two
switches tie for
position as the root
switch.
stp-admin-p2p I Admin P2P of STP switch(config)#interface fastEthernet
[Auto|True|False] priority on this 2
interface. switch(config-if)# stp-admin-p2p
Auto
stp-admin-edge I Admin Edge of STP switch(config)#interface fastEthernet
[True|False] priority on this 2
interface. switch(config-if)# stp-admin-edge
True
stp-admin-non-stp I Admin NonSTP of switch(config)#interface fastEthernet
[True|False] STP priority on this 2
interface. switch(config-if)# stp-admin-non-stp
False
Show spanning-tree E Display a summary of switch>show spanning-tree
the spanning-tree
states.
no spanning-tree G Disable spanning-tree. switch(config)#no spanning-tree
6.7 Commands Set List—QoS command set
IES-3073GC Commands Level Description Example
qos policy G Select QOS policy switch(config)#qos policy
ORing Industrial Networking Corp 87
IES-3073GC User’s Manual
[weighted-fair|strict] scheduling weighted-fair
qos prioritytype G Setting of QOS switch(config)#qos prioritytype
[port-based|cos-only|tos priority type
-only|cos-first|tos-first]
qos priority portbased G Configure Port-based switch(config)#qos priority portbased
[Port] Priority 1 low
[lowest|low|middle|high]
qos priority cos G Configure COS switch(config)#qos priority cos 22
[Priority][lowest|low|mid Priority middle
dle|high]
qos priority tos G Configure TOS switch(config)#qos priority tos 3 high
[Priority][lowest|low|mid Priority
dle|high]
show qos P Display the switch>show qos
information of QoS
configuration
no qos G Disable QoS function switch(config)#no qos
6.8 Commands Set List—IGMP command set
IES-3073GC Commands Level Description Example
igmp enable G Enable IGMP switch(config)#igmp enable
snooping function
Igmp-query auto G Set IGMP query to switch(config)#Igmp-query auto
auto mode
Igmp-query force G Set IGMP query to switch(config)#Igmp-query force
force mode
show igmp P Displays the details of switch#show igmp configuration
configuration an IGMP
configuration.
show igmp multi P Displays the details of switch#show igmp multi
an IGMP snooping
entries.
no igmp G Disable IGMP switch(config)#no igmp
snooping function
no igmp-query G Disable IGMP query switch#no igmp-query
ORing Industrial Networking Corp 88
IES-3073GC User’s Manual
6.9 Commands Set List—MAC/Filter Table command set
IES-3082GC Commands Level Description Example
mac-address-table static I Configure MAC switch(config)#interface fastEthernet
hwaddr address table of 2
[MAC] interface (static). switch(config-if)#mac-address-table
static hwaddr 000012345678
mac-address-table filter G Configure MAC switch(config)#mac-address-table
hwaddr address table(filter) filter hwaddr 000012348678
[MAC]
show mac-address-table P Show all MAC switch#show mac-address-table
address table
show mac-address-table P Show static MAC switch#show mac-address-table
static address table static
show mac-address-table P Show filter MAC switch#show mac-address-table filter
filter address table.
no mac-address-table I Remove an entry of switch(config)#interface fastEthernet
static hwaddr MAC address table of 2
[MAC] interface (static) switch(config-if)#no
mac-address-table static hwaddr
000012345678
no mac-address-table G Remove an entry of switch(config)#no mac-address-table
filter hwaddr MAC address table filter hwaddr 000012348678
[MAC] (filter)
no mac-address-table G Remove dynamic switch(config)#no mac-address-table
entry of MAC address
table
6.10 Commands Set List—SNMP command set
IES-3073GC Commands Level Description Example
snmp agent-mode G Select the agent mode switch(config)#snmp agent-mode
[v1v2c | v3] of SNMP v1v2c
snmp-server host G Configure SNMP switch(config)#snmp-server host
[IP address] server host 192.168.10.50 community public
ORing Industrial Networking Corp 89
IES-3073GC User’s Manual
community information and trap-version v1
[Community-string] community string (remove)
trap-version Switch(config)#
[v1|v2c] no snmp-server host
192.168.10.50
snmp G Configure the switch(config)#snmp
community-strings community string right community-strings public right RO
[Community-string] or
right switch(config)#snmp
[RO|RW] community-strings public right RW
snmp snmpv3-user G Configure the switch(config)#snmp snmpv3-user
[User Name] userprofile for test01 password AuthPW PrivPW
password SNMPV3 agent.
[Authentication Privacy password
Password] [Privacy could be empty.
Password]
show snmp P Show SNMP switch#show snmp
configuration
show snmp-server P Show specified trap switch#show snmp-server
server information
no snmp G Remove the specified switch(config)#no snmp
community-strings community. community-strings public
[Community]
no snmp snmpv3-user G Remove specified switch(config)# no snmp
[User Name] user of SNMPv3 snmpv3-user test01 password
password agent. Privacy AuthPW PrivPW
[Authentication password could be
Password] [Privacy empty.
Password]
no snmp-server host G Remove the SNMP switch(config)#no snmp-server
[Host-address] server host. 192.168.10.50
6.11 Commands Set List—Port Mirroring command set
IES-3073GC Commands Level Description Example
monitor rx G Set RX destination switch(config)#monitor rx
port of monitor
ORing Industrial Networking Corp 90
IES-3073GC User’s Manual
function
monitor tx G Set TX destination switch(config)#monitor tx
port of monitor
function
show monitor P Show port monitor switch#show monitor
information
monitor I Configure source port switch(config)#interface fastEthernet
[RX|TX|Both] of monitor function 2
switch(config-if)#monitor RX
show monitor I Show port monitor switch(config)#interface fastEthernet
information 2
switch(config-if)#show monitor
no monitor I Disable source port of switch(config)#interface fastEthernet
monitor function 2
switch(config-if)#no monitor
6.12 Commands Set List—802.1x command set
IES-3073GC Commands Level Description Example
8021x enable G Use the 802.1x global switch(config)# 8021x enable
configuration
command to enable
802.1x protocols.
8021x system radiousip G Use the 802.1x switch(config)# 8021x system
[IP address] system radious IP radiousip 192.168.1.1
global configuration
command to change
the radious server IP.
8021x system serverport G Use the 802.1x switch(config)# 8021x system
[port ID] system server port serverport 1815
global configuration
command to change
the radious server port
8021x system G Use the 802.1x switch(config)# 8021x system
accountport system account port accountport 1816
[port ID] global configuration
command to change
ORing Industrial Networking Corp 91
IES-3073GC User’s Manual
the accounting port
8021x system sharekey G Use the 802.1x switch(config)# 8021x system
[ID] system share key sharekey 123456
global configuration
command to change
the shared key value.
8021x system nasid G Use the 802.1x switch(config)# 8021x system nasid
[words] system nasid global test1
configuration
command to change
the NAS ID
8021x misc quietperiod G Use the 802.1x misc switch(config)# 8021x misc
[sec.] quiet period global quietperiod 10
configuration
command to specify
the quiet period value
of the switch.
8021x misc txperiod G Use the 802.1x misc switch(config)# 8021x misc txperiod
[sec.] TX period global 5
configuration
command to set the
TX period.
8021x misc G Use the 802.1x misc switch(config)# 8021x misc
supportimeout [sec.] supp timeout global supportimeout 20
configuration
command to set the
supplicant timeout.
8021x misc G Use the 802.1x misc switch(config)#8021x misc
servertimeout [sec.] server timeout global servertimeout 20
configuration
command to set the
server timeout.
8021x misc maxrequest G Use the 802.1x misc switch(config)# 8021x misc
[number] max request global maxrequest 3
configuration
command to set the
ORing Industrial Networking Corp 92
IES-3073GC User’s Manual
MAX requests.
8021x misc G Use the 802.1x misc switch(config)# 8021x misc
reauthperiod [sec.] reauth period global reauthperiod 3000
configuration
command to set the
reauth period.
8021x portstate I Use the 802.1x port switch(config)#interface fastethernet
[disable | reject | accept | state interface 3
authorize] configuration switch(config-if)#8021x portstate
command to set the accept
state of the selected
port.
show 8021x E Display a summary of switch>show 8021x
the 802.1x properties
and also the port
sates.
no 8021x G Disable 802.1x switch(config)#no 8021x
function
6.13 Commands Set List—TFTP command set
Defaults
IES-3073GC Commands Level Description
Example
backup G Save configuration to switch(config)#backup
flash:backup_cfg TFTP and need to flash:backup_cfg
specify the IP of TFTP
server and the file
name of image.
restore flash:restore_cfg G Get configuration from switch(config)#restore
TFTP server and need flash:restore_cfg
to specify the IP of
TFTP server and the
file name of image.
ORing Industrial Networking Corp 93
IES-3073GC User’s Manual
upgrade G Upgrade firmware by switch(config)#upgrade
flash:upgrade_fw TFTP and need to lash:upgrade_fw
specify the IP of TFTP
server and the file
name of image.
6.14 Commands Set List—SYSLOG, SMTP, EVENT command
set
IES-3073GC Commands Level Description Example
systemlog ip G Set System log server switch(config)# systemlog ip
[IP address] IP address. 192.168.1.100
systemlog mode G Specified the log switch(config)# systemlog mode
[client|server|both] mode both
show systemlog E Display system log. Switch>show systemlog
show systemlog P Show system log switch#show systemlog
client & server
information
no systemlog G Disable systemlog switch(config)#no systemlog
functon
smtp enable G Enable SMTP function switch(config)#smtp enable
smtp serverip G Configure SMTP switch(config)#smtp serverip
[IP address] server IP 192.168.1.5
smtp authentication G Enable SMTP switch(config)#smtp authentication
authentication
smtp account G Configure switch(config)#smtp account User
[account] authentication
account
smtp password G Configure switch(config)#smtp password
[password] authentication
password
smtp rcptemail G Configure Rcpt e-mail switch(config)#smtp rcptemail 1
[Index] [Email address] Address
[email protected]show smtp P Show the information switch#show smtp
of SMTP
no smtp G Disable SMTP switch(config)#no smtp
ORing Industrial Networking Corp 94
IES-3073GC User’s Manual
function
event device-cold-start G Set cold start event switch(config)#event
[Systemlog|SMTP|Both] type device-cold-start both
event G Set Authentication switch(config)#event
authentication-failure failure event type authentication-failure both
[Systemlog|SMTP|Both]
event G Set s ring topology switch(config)#event
O-Ring-topology-change changed event type ring-topology-change both
[Systemlog|SMTP|Both]
event systemlog I Set port event for switch(config)#interface fastethernet
[Link-UP|Link-Down|Bot system log 3
h] switch(config-if)#event systemlog
both
event smtp I Set port event for switch(config)#interface fastethernet
[Link-UP|Link-Down|Bot SMTP 3
h] switch(config-if)#event smtp both
show event P Show event selection switch#show event
no event G Disable cold start switch(config)#no event
device-cold-start event type device-cold-start
no event G Disable Authentication switch(config)#no event
authentication-failure failure event typ authentication-failure
no event G Disable O-Ring switch(config)#no event
O-Ring-topology-change topology changed ring-topology-change
event type
no event systemlog I Disable port event for switch(config)#interface fastethernet
system log 3
switch(config-if)#no event systemlog
no event smpt I Disable port event for switch(config)#interface fastethernet
SMTP 3
switch(config-if)#no event smtp
show systemlog P Show system log switch#show systemlog
client & server
information
6.15 Commands Set List—SNTP command set
IES-3073GC Commands Level Description Example
ORing Industrial Networking Corp 95
IES-3073GC User’s Manual
sntp enable G Enable SNTP function switch(config)#sntp enable
sntp daylight G Enable daylight saving switch(config)#sntp daylight
time, if SNTP function
is inactive, this
command can’t be
applied.
sntp daylight-period G Set period of daylight switch(config)# sntp daylight-period
[Start time] [End time] saving time, if SNTP 20060101-01:01 20060202-01-01
function is inactive,
this command can’t be
applied.
Parameter format:
[yyyymmdd-hh:mm]
sntp daylight-offset G Set offset of daylight switch(config)#sntp daylight-offset 3
[Minute] saving time, if SNTP
function is inactive,
this command can’t be
applied.
sntp ip G Set SNTP server IP, if switch(config)#sntp ip 192.169.1.1
[IP] SNTP function is
inactive, this
command can’t be
applied.
sntp timezone G Set timezone index, switch(config)#sntp timezone 22
[Timezone] use “show sntp
timzezone” command
to get more
information of index
number
show sntp P Show SNTP switch#show sntp
information
show sntp timezone P Show index number of switch#show sntp timezone
time zone list
no sntp G Disable SNTP switch(config)#no sntp
function
no sntp daylight G Disable daylight switch(config)#no sntp daylight
ORing Industrial Networking Corp 96
IES-3073GC User’s Manual
saving time
6.16 Commands Set List—O-Ring command set
IES-3073GC Commands Level Description Example
Ring enable G Enable O-Ring switch(config)# ring enable
Ring master G Enable ring master switch(config)# ring master
Ring couplering G Enable couple ring switch(config)# ring couplering
Ring dualhoming G Enable dual homing switch(config)# ring dualhoming
Ring ringport G Configure 1st/2nd switch(config)# ring ringport 7 8
[1st Ring Port] [2nd Ring Ring Port
Port]
Ring couplingport G Configure Coupling switch(config)# ring couplingport 1
[Coupling Port] Port
Ring controlport G Configure Control Port switch(config)# ring controlport 2
[Control Port]
Ring homingport G Configure Dual switch(config)# ring homingport 3
[Dual Homing Port] Homing Port
show Ring P Show the information switch#show ring
of O-Ring
no Ring G Disable O-Ring switch(config)#no ring
no Ring master G Disable ring master switch(config)# no ring master
no Ring couplering G Disable couple ring switch(config)# no ring couplering
no Ring dualhoming G Disable dual homing switch(config)# no ring dualhoming
ORing Industrial Networking Corp 97
IES-3073GC User’s Manual
Technical Specifications
Technology
Ethernet Standards 802.3 - 10Base-T,
802.3u - 100Base-TX, 100Base-FX,
802.3z - 1000Base-X
802.3ab - 1000Base-TX,
802.3ad - Link Aggregation Control Protocol
802.3x - Flow Control
802.1D - Spanning Tree Protocol
802.1p - Class of Service,
802.1Q - VLAN Tagging
802.1w - Rapid Spanning Tree Protocol,
802.1X - Authentication
802.1ad - VLAN QinQ
802.1AB - LLDP
802.1s - MSTP
MAC addresses 8192
Priority Queues 4
Flow Control IEEE 802.3x Flow Control and Back-pressure
Processing Store-and-Forward
Interface
RJ45 Ports 10/100Base-T(X), Auto MDI/MDI-X
Gigabit SFP Ports (combo port) 100/1000 Base-X SFP connector
Gigabit RJ45 Ports (combo port) 10/100/1000 Base-T(X), Auto MDI/MDIX
LED Indicators Per Unit : Power x 3(Green)
RJ45 Ports:
Per Port : Link/Activity(Green/Blinking Green), Full
duplex(Amber)
Gigabit RJ-45 Ports:
Per Port : Activity/Link(Green), 100Mbps indicator
(Amber)
Gigabit SFP Ports :
Per Port : Activity/Link(Green)
Power Requirements
ORing Industrial Networking Corp 98
IES-3073GC User’s Manual
Power Input Voltage PWR1/2: 12 to 48VDC on 6-pin Terminal Block
Reverse Polarity Protection Present at terminal block
Power Consumption 12 Watts Max
Environmental
Operating Temperature -40 to 70 oC
Storage Temperature -40 to 85 oC
Operating Humidity 5% to 95%, non-condensing
Mechanical
Dimensions(W x D x H) 74.3 mm(W)x 109.2 mm(D)x 153.6 mm(H)
Casing IP-30 protection
Regulatory Approvals
Regulatory Approvals FCC Part 15, CISPER (EN55022) class A
EMS EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4
(EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS)
Shock IEC 60068-2-27
Free Fall IEC 60068-2-32
Vibration IEC 60068-2-6
Warranty 5 years
ORing Industrial Networking Corp 99