ETICS Fixings / E.W.I
ETICS Fixings / E.W.I
I
Dear Partners,
According to an ancient native American saying, „we have
not inherited the earth from our parents but are merely borro-
wing it from our children“. This prescient wisdom held by the
native Americans is now more applicable than ever. The fact
that our natural resources are limited and that we should only
use what we can replace is still given too little heed. Every
one of us can be more aware and can do more to avoid waste.
The fischer group of companies is answering this challenge
with innovative solutions for energy-efficient construction,
amongst other things. The ever-increasing requirements
with regard to the thermal protection of buildings are conti-
nuously increasing the need for façades that feature thermal
insulation composite systems, as well the demand for insu-
lation fixings. We offer a range of approved fixing systems in
line with the European Technical Approvals (ETA) for ETICS
system providers. The following pages provide an overview
of the extensive range of products and services that we
have to offer, as well as a description of the various items.
Here you will not just find all of the hammerset and screw
fixings that we offer for systems; you can also view our
special fixings – these provide an easy-to-use and satis-
factory building solution for every fixing problem.
We hope that you enjoy using the fixing systems presen-
ted here. Should you have any further questions or if you
require personal assistance, please utilise the service pro-
vided by our experts via the technical support hotline, or
by our dedicated and experienced technical support staff.
.
Klaus Fischer
Fixing selection
1) Only for termoz CN 8/370
Content
Service 2 1
Hammerset fixings 8 2
Screw fixings 18 3
Discs 32 4
Miscellaneous 36 5
1
Service A brand and its promise to perform
2
Service
Tailor-made services for you
In order to maintain close contact
with the market and system Active sales service in over 100 countries
manufacturers, the E.W.I.(External Cost-effective technical advice in line with directives
Wall Insulation) department at
fischer Deutschland Vertriebs
provided by over 130 engineers worldwide 1
Prototypes, extraction tests, individual calculations,
GmbH is a member of the ETICS
comparisons and development of customised solutions,
professional association. This
technical documentation and online services
ensures that we are able to
develop new innovative products Free software tools, including the Fixperience design
and can benefit from a constant software suite, CAD-FIX 3D fixings database, etc.
exchange of expertise. Practical training courses in the fischer Academy and
across Germany in the Competence Centres
ETICS fixings are exclusively sold by ETICS licence holders.
3
Service Approved
Gute Gründe
hammerset
für fischer
fixings
1)
(110, 370 and 390 = 0.001)
4
Approved screw fixings
Service
1
1)
(100 - 400 mm)
2)
(From 150 mm
insulation thickness)
5
Service FixingGründe
Gute selection
für fischer
Usage cate-
gory A
Concrete
Usage cate-
gory B
Usage cate-
gory C
1 Vertically perforated brick Perforated sand-lime brick Hollow blocks made from lightweight concrete
Usage cate-
gory D
Usage cate-
gory E
Aeratet concrete
Adhesive layer
} ttol
possible fixing safety. The specific characteristics of the job in hand must
always be taken into account hD
Determination of the required fixing length:
Anchorage depth hnom
+ Tolerance compensation ttol
+ Insulation thickness hD
= Required fixing length lD
6
Basic Knowledge of Drilling Technology
Service
Drilling
The building material is decives when drilling. Four methods are available:
Rotary drilling: Drilling in rotary mode without impact, with a sharply ground carbide
drill bit. For perforated bricks and materials with low strength, the drill hole does not
become too large with it and the bars in the perforated bricks do not break.
Carbide drill bits drill faster if they are ground sharp, similar to steel drill bits. There are
also special masonry drill bits available.
Rotary drilling Impact drilling: Rotation and a high number of light impacts with the impact drilling
machine, for solid building materials with dense structure.
Hammer drilling: Rotation and a small number of minor impacts with high impact
energy with the drilling hammer, also for solid building materials with dense structure.
Impact
drilling
Hammer
drilling
▸ Expert tip
• For almost all permissible fixings, rotary drillings and hammer drillings are
prescribed in the approval or guideline. 1
• Do not use drills with excessively worn out cutting edge width across
corners anymore (see rules of approval).
• The drill hole depth is always specified exactly and based on a definite thickness of
the anchoring base. The following rule of thumb is followed for general applications
without approval: Necessary thickness of the anchoring base = drill hole depth + 30
mm.
• To avoid tilting of the fixture, it must always be drilled perpendicular to the
anchoring base. Exceptional cases are regulated in the anchor approvals and/or the
manufacturer’s specifications (up to 5 ° is tolerable).
7
Hammerset fixings termoz LO 8
8
termoz LO 8
TECHNICAL DATA
Hammerset fixings
l
Ø 60 mm
termoz LO 8
h nom t fix
LOADS
Permissible loads1) 4) for a single anchor for fixing of external thermal insulation composite systems
For the design the complete approval ETA-10/0460 has to be considered.
min. raw density class min. compressive brick Drilling method 2) Permissible loads
strength according ETA-approval
ρ fb
3)
Base material [kg/dm³] [N/mm²] [-] [kN]
Concrete C12/15 H 0,17
Concrete C16/20 H 0,17
Concrete C50/60 H 0,17
Solid sand-lime brick KS 1,8 12 H 0,20
Solid brick Mz 2,0 12 R 0,20
1)
The required partial safety factors for material resistance as well as a partial safety factor for load actions F = 1,5 are considered.
2)
H = Hammer drilling; R = Rotary drilling
3)
Restrictions concerning each producer and the possible hole pattern resp. web thickness please see approval. The characteristic tension resistance of the anchor may be determined by means of job site
pullout tests carried out on the material actually used, if a characteristic resistance of the base material does not exist.
4)
Tensile loads only
9
Hammerset fixings termoz PN 8
10
termoz PN 8
TECHNICAL DATA
Hammerset fixings
l
Ø 60 mm
termoz PN 8
h nom t fix
LOADS
Permissible loads1) 4) for a single anchor for fixing of external thermal insulation composite systems
For the design the complete approval ETA-09/0171 has to be considered.
min. raw density class min. compressive brick Drilling method 2) Permissible loads
strength according ETA-approval
ρ fb
3)
Base material [kg/dm³] [N/mm²] [-] [kN]
Concrete C12/15 H 0,17
Concrete C16/20 H 0,17
Concrete C50/60 H 0,17
Solid sand-lime brick KS 1,8 12 H 0,20
Solid brick Mz 2,0 12 R 0,20
Perforated sand-lime brick KSL 1,4 12 H 0,13
Vertically perforated brick Hlz 1,0 12 R 0,13
Hollow brick of lightweight aggregate concrete Hbl 1,2 10 H 0,17
Triple-skin outer wall panels made of concrete C20/25 H 0,17
1)
The required partial safety factors for material resistance as well as a partial safety factor for load actions F = 1,5 are considered.
2)
H = Hammer drilling; R = Rotary drilling
3)
Restrictions concerning each producer and the possible hole pattern resp. web thickness please see approval. The characteristic tension resistance of the anchor may be determined by means of job site
pullout tests carried out on the material actually used, if a characteristic resistance of the base material does not exist.
4)
Tensile loads only
11
Hammerset fixings termofix CF 8
Polystyrene rigid foam boards on solid brick Mineralwool boards on a brick wall
12
termofix CF 8
TECHNICAL DATA
Hammerset fixings
l
Ø 60 mm
termofix CF 8
h nom t fix
LOADS
Permissible loads1) 4) for a single anchor for fixing of external thermal insulation composite systems
For the design the complete approval ETA-07/0287 has to be considered.
min. raw density class min. compressive brick Drilling method 2) Permissible loads
strength according ETA-approval
ρ fb
Base material 3) [kg/dm³] [N/mm²] [-] [kN]
Concrete C12/15 H 0,20
Concrete C16/20 H 0,25
Concrete C50/60 H 0,30
Solid sand-lime brick KS 1,8 12 H 0,25
Solid brick Mz 2,0 12 H 0,30
Full blocks made from concrete Vbn 2,0 20 H 0,20
Perforated sand-lime brick KSL 1,4 12 H 0,25
Vertically perforated brick Hlz 1,0 12 R 0,20
Hollow blocks made from lightweight concrete Hbl 1,2 10 H 0,17
Solid blocks made from lightweight concrete Vbl 1,4 8 H 0,10
Lightweight aggregate concrete LAC 0,8 4 H 0,10
Lightweight aggregate concrete LAC 0,8 6 H 0,13
Triple-skin outer wall panels made of concrete C20/25 H 0,25
1)
The required partial safety factors for material resistance as well as a partial safety factor for load actions F = 1,5 are considered.
2)
H = Hammer drilling; R = Rotary drilling
3)
Restrictions concerning each producer and the possible hole pattern resp. web thickness please see approval. The characteristic tension resistance of the anchor may be determined by means of job site
pullout tests carried out on the material actually used, if a characteristic resistance of the base material does not exist.
4)
Tensile loads only
13
Hammerset fixings termoz CN 8
14
termoz CN 8
TECHNICAL DATA
Hammerset fixings
l
Ø 60 mm
termoz CN 8
h nom t fix
LOADS
Permissible loads1) 4) for a single anchor for fixing of external thermal insulation composite systems
For the design the complete approval ETA-09/0394 has to be considered.
min. raw density class min. compressive brick Drilling method 2) Permissible loads
strength according ETA-approval
ρ fb
Base material 3) [kg/dm³] [N/mm²] [-] [kN]
Concrete C12/15 H 0,30
Concrete C16/20 H 0,30
Concrete C50/60 H 0,30
Solid sand-lime brick KS 1,8 12 H 0,30
Solid brick Mz 2,0 12 H 0,30
Full blocks made from concrete Vbn 2,0 20 H 0,25
Perforated sand-lime brick KSL 1,4 12 H 0,17
Vertically perforated brick Hlz 1,0 12 R 0,20
Hollow blocks made from lightweight concrete Hbl 1,2 10 H 0,20
Solid blocks made from lightweight concrete Vbl 1,4 8 H 0,20
Lightweight aggregate concrete LAC 0,8 4 H 0,13
Lightweight aggregate concrete LAC 0,8 6 H 0,20
Triple-skin outer wall panels made of concrete C20/25 H 0,30
1)
The required partial safety factors for material resistance as well as a partial safety factor for load actions F = 1,5 are considered.
2)
H = Hammer drilling; R = Rotary drilling
3)
Restrictions concerning each producer and the possible hole pattern resp. web thickness please see approval. The characteristic tension resistance of the anchor may be determined by means of job site
pullout tests carried out on the material actually used, if a characteristic resistance of the base material does not exist.
4)
Tensile loads only
15
Hammerset fixings termofix PN 8
BUILDING MATERIALS
▪ Concrete
▪ Building brick
▪ Solid sand-lime brick
▪ Vertically perforated brick
▪ Perforated sand-lime brick
16
termofix PN 8
TECHNICAL DATA
Hammerset fixings
l
Ø 60 mm
termofix PN 8
h nom t fix
17
Screw fixings termoz CS 8
18
termoz CS 8
Screw fixings
COUNTERSUNK INSTALLATION
ACCESSORIES
19
termoz CS 8
TECHNICAL DATA
Screw fixings
termoz CS 8
Drill diameter Fixing length Effect. ancho- Min. drill Max. usable Min. drill Max. usable Drive Sales unit
rage depth hole depth at length at hole depth at length at
Approval
20
termoz CS 8
LOADS
Screw fixings
termoz CS 8 3)
Highest permissible loads for a single anchor1) 4) for multiple use for non-structural applications.
For the design the complete assessment ETA-14/0372 has to be considered.
Beton und Mauerwerk
Type Brick raw density min. compressive min. min. permissible min. min.
brick strength embedment depth member thickness tensile load 3) spacing 2) edge distance 2)
fb hnom hmin Nzul smin cmin
[kg/dm³] [N/mm²] [mm] [mm] [kN] [mm] [mm]
Concrete
C12/15 - C45/55 0,40
CS 8 356) 100 100 100
C50/60 0,50
Weather shell
C20/25 - C45/55 0,40
CS 8 356) 5) 42 100 100
C50/60 0,50
Solid Clay bricks e.g. acc. to DIN 105-100:2012-01, EN 771-1:2011, Mz
CS 8 ≥ 1,8 20 356) 100 0,50 100 100
Calcium silicate solid bricks, e.g. acc. to DIN V 106:2005-10, EN 771-2:2011, KS
20 0,50
CS 8 ≥ 1,8 356) 100 100 100
12 0,30
Solid lightweight concrete block, e.g. acc. to DIN V 18152-100:2005-10 EN 771-3:2011 Vbl
CS 8 ≥ 1,4 8 356) 100 0,17 100 100
Solid concrete block, e.g. acc. to DIN V 18152-100:2005-10 EN 771-3:2011, Vbn
20 0,40
CS 8 ≥ 2,0 356) 100 100 100
12 0,25
Vertically perforated clay bricks e.g. acc. to DIN 105-100:2012-01, EN 771-1:2011, HLz
≥ 1,0 12 0,20
CS 8 257) 100 100 100
≥ 1,6 48 0,50
Hollow calcium silicate brick, acc. to DIN V 106:2005-10, EN 771-2:2011, KSL
20 0,30
CS 8 ≥ 1,4 257) 100 100 100
12 0,17
Hollow brick light-weight concrete, e.g. acc. to DIN V 18153-100: 2005-10, EN 771-3:2011 Hbl
CS 8 ≥ 0,9 4 256) 100 0,17 100 100
Hollow brick concrete, e.g. acc. to DIN V 18153-100: 2005-10, EN 771-3:2011 Hbn
10 0,40
8 0,30
CS 8 ≥ 1,2 25 6)
100 100 100
6 0,25
4 0,17
Lightweight Aggregate Concrete acc. to DIN EN 1520, LAC
CS 8 ≥ 0,9 6 356) 100 0,25 100 100
Autoclaved aerated concrete blocks, e.g. AAC acc. to DIN V 4165-100:2005-10, EN 771-4
4 357) 0,10
CS 8 ≥ 0,5 100 100 100
4 557) 0,20
1)
The partial safety factors for material resistance as regulated in the assessment as well as a 4)
The given loads are valid for installation and use of fixations in dry masonry for temperatures in
partial safety factor for load actions of F = 1,5 are considered. the substrate up to +24 °C (resp. short term up to 40 °C).
2)
Minimum possible axial spacings resp. edge distances acc. Assessment. 5)
Embedment depth permitted up to 45 mm.
3)
Plastic anchor for fixing of external thermal insulation composite systems with rendering acc. 6)
Hammer drilling
ETAG014. Only tensile wind loads are permitted. 7)
Rotary drilling
21
termoz 8 U
screw
22
termoz 8 U
TECHNICAL DATA
Screw fixings
termoz 8U
- Pre-assembled with screw T30
h nom
h1
ACCESSORIES
LOADS
Permissible loads1) 4) for a single anchor for fixing of external thermal insulation composite systems
For the design the complete approval ETA-02/0019 has to be considered.
min. raw density class min. compressive brick Drilling method 2) Permissible loads
strength according ETA-approval
ρ fb
3)
Base material [kg/dm³] [N/mm²] [-] [kN]
Concrete C12/15 H 0,50
Concrete C16/20 H 0,50
Concrete C50/60 H 0,50
Solid sand-lime brick KS 1,6 12 H 0,50
Solid brick Mz 1,6 12 H 0,50
Perforated sand-lime brick KSL 1,4 12 H 0,25
Vertically perforated brick Hlz 1,2 12 R 0,25
Hollow blocks made from lightweight concrete Hbl 0,5 2 R 0,13
Solid blocks made from lightweight concrete Vbl 0,5 4 R 0,20
Aerated concrete PP 0,5 4 R 0,40
Triple-skin outer wall panels made of concrete C20/25 H 0,50
1)
The required partial safety factors for material resistance as well as a partial safety factor for load actions F = 1,5 are considered.
2)
H = Hammer drilling; R = Rotary drilling
3)
Restrictions concerning each producer and the possible hole pattern resp. web thickness please see approval. The characteristic tension resistance of the anchor may be determined by means of job site
pullout tests carried out on the material actually used, if a characteristic resistance of the base material does not exist.
4)
Tensile loads only
23
termoz SV II ecotwist
material classes
24
termoz SV II ecotwist
TECHNICAL DATA
Screw fixings
Ø 66 mm
termoz SV II ecotwist
h ef t tol hD
h nom
h1
Insulation Shaft Thickness Effect. ancho- Shaft length Drillhole Total drill Sales unit
Approval
thickness diameter tolerance rage depth in drill hole depth in base hole depth
compensation material
hD ttol hef hnom h1
ETA [mm] [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
Item Art.-No.
termoz SV II ecotwist 0-10 530353 ■ 100 - 400 8 0 - 10 35 45 55 hD + 55 100
termoz SV II ecotwist 10-30 530354 ■ 100 - 400 8 0 - 30 35 65 75 hD + 75 100
termoz SV II ecotwist 30-60 530355 ■ 100 - 400 8 30 - 60 35 95 105 hD + 105 100
ACCESSORIES
Sales unit
LOADS
Permissible loads1) 4) for a single anchor for fixing of external thermal insulation composite systems
For the design the complete approval ETA-12/0208 has to be considered.
min. raw density class min. compressive brick Drilling method 2) Permissible loads
strength according ETA-approval
ρ fb
3)
Base material [kg/dm³] [N/mm²] [-] [kN]
Concrete C12/15 H 0,50
Concrete C16/20 H 0,50
Concrete C50/60 H 0,50
Solid sand-lime brick KS 2,0 12 H 0,40
Solid sand-lime brick KS 2,0 20 H 0,50
Solid brick Mz 1,8 12 H 0,40
Full blocks made from concrete Vbn 2,0 12 H 0,40
Full blocks made from concrete Vbn 2,0 20 H 0,50
Perforated sand-lime brick KSL 1,4 12 H 0,25
Perforated sand-lime brick KSL 1,4 20 H 0,40
Vertically perforated brick Hlz 1,0 12 R 0,25
Hollow blocks made from lightweight concrete Hbl 1,2 8 H 0,30
Hollow blocks made from lightweight concrete Hbl 1,2 10 H 0,20
Solid blocks made from lightweight concrete Vbl 1,4 8 H 0,20
Lightweight aggregate concrete LAC 1,0 6 H 0,25
Aerated concrete PP 0,5 4 R 0,13
Triple-skin outer wall panels made of concrete C20/25 H 0,30
1)
The required partial safety factors for material resistance as well as a partial safety factor for load actions F = 1,5 are considered.
2)
H = Hammer drilling; R = Rotary drilling
3)
Restrictions concerning each producer and the possible hole pattern resp. web thickness please see approval. The characteristic tension resistance of the anchor may be determined by means of job site
pullout tests carried out on the material actually used, if a characteristic resistance of the base material does not exist.
4)
Tensile loads only
25
termofix 6H-NT
Fixing of wooden soft fibre boards on solid Attachment of polystyrene boards on OSB-
wood panel
BUILDING MATERIALS
▪ 3-layer boards
▪ MDF boards
▪ OSB boards
▪ Chipboard
▪ Gypsum fibreboard
▪ Solid wood
26
termofix 6H-NT
Screw fixings
COUNTERSUNK INSTALLATION
TECHNICAL DATA
termofix 6H-NT
surface-flush installation
recessed installation
Fixing length Disk Ø Screw diameter Anchorage depth Usable length Usable length at Sales unit
at surface-flush anchorage depth
installation 70mm
l ds hv tfix tfix
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
termofix 6H-NT 60 523198 1) 60 60 6,0 35 30 — 100
termofix 6H-NT 80 523199 80 60 6,0 30 50 65 100
termofix 6H-NT 100 523200 100 60 6,0 30 70 85 100
termofix 6H-NT 120 523201 120 60 6,0 30 90 105 100
termofix 6H-NT 140 523202 140 60 6,0 30 110 125 100
termofix 6H-NT 160 523203 160 60 6,0 30 130 145 100
termofix 6H-NT 180 523204 180 60 6,0 30 150 165 100
termofix 6H-NT 200 523205 200 60 6,0 30 170 185 100
termofix 6H-NT 220 523206 220 60 6,0 30 190 205 100
termofix 6H-NT 240 523207 240 60 6,0 30 210 225 100
termofix 6H-NT 260 523208 260 60 6,0 30 230 245 100
termofix 6H-NT 280 523209 280 60 6,0 30 250 265 100
termofix 6H-NT 300 523210 300 60 6,0 30 270 285 100
termofix 6H-NT 320 523211 320 60 6,0 30 290 305 100
1) suitable for flush-mounting installation only
27
Screw fixings termofix 6H-NT
LOADS
termofix 6H-NT
Extraction values in various building materials.
Anchoring substrate Thickness Recommended maximum service load
values from internal laboratory tests
d safety coefficient 3, dephtment 30 mm
[mm] [kN]
OSB panel 16 0,40
Timber planking FP (laminated particle board) 16 0,30
3 Layer panel 19 0,50
Beams 60 0,60 (bei hv 40 = 1,0 kN)
Gypsum fibre board 12,5 0,15
MDF board 19 0,50
28
Screw fixings
Advantage for professionals:
The fischer International Catalogue offers lots of facts and helps with fast and
secure product selection. Over 300 pages of
▪ Product descriptions with advantages/benefits overview
▪ Installation tips
▪ Application aids
▪ Detailed technical data
▪ Fundamentals of fastening technology
29
termofix B
BUILDING MATERIALS
▪ Metal sheet / trapezoidal metal sheet
up to 1.5 mm
30
termofix B
TECHNICAL DATA
Screw fixings
l
termofix B
h t fix
Effect. anchorage Fixing length Max. usable Screw length Disk Ø Drive Sales unit
depth length
h l tfix ls
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs]
termofix B 70 008691 20 70 50 60 60 PH 2 100
termofix B 90 008692 20 90 70 80 60 PH 2 100
termofix B 110 008693 20 110 90 100 60 PH 2 100
termofix B 130 008694 20 130 110 120 60 PH 2 100
termofix B 160 008695 20 160 140 150 60 PH 2 100
termofix B 180 008696 20 180 160 170 60 PH 2 100
31
Insulation Disc DT
screw fixings
TECHNICAL DATA
DT 90 DT 110 DT 140
Disk Ø Sales unit
32
termofix H
Discs
The disc element for use with standard screws
BUILDING MATERIALS
▪ Panel building materials
▪ Solid wood
TECHNICAL DATA
termofix H 90
33
Discs Insulation discs
34
Insulation discs
TECHNICAL DATA
Discs
HV 36 plastic HV 36 zinc ISO-disk 8/60 DT 60/10 DTM-A4 DTM 70/10 DT 90
Disk Ø Disc height Through hole Steel sheet Sales unit
thickness
df s
Item Art.-No. [mm] [mm] [mm] [mm] [pcs]
HK 36 plastic 004283 36 4.5 5 — 100
HV 36 zinc 004286 36 3.5 5 0,7 100
HA 36 st. st. A4 004285 36 3.5 5 — 100
ISO-disk 8/60 001680 60 7 8 — 100
DT 60/10 044317 60 7 10 — 50
DTM 60/10 A4 088805 60 3 10,5 0,5 100
DTM 70/10 zinc 044318 70 3 10,5 — 50
DT 90/4 080957 1) 90 9.3 4 — 250
DT 90/8 080958 90 9.3 8,2 — 250
1) The central hole is adapted in such a way that the disc clamps well on the 4 mm wire of the VB walltie.
35
Hammerfix N-F
installation
36
Hammerfix N-F
TECHNICAL DATA
Miscellaneous
Hammerfix N-F with cylindrical head and
nail, pre-assembled
Drill hole diameter Effect. anchorage Anchor length Min. drill hole depth Max. fixture thick- Sales unit
depth for through fixings ness
d0 hef l h2 t fix
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs]
N 6 x 40/10 F (50) 513837 6 30 40 55 10 50
N 6 x 40/10 F (100) 513840 6 30 40 55 10 100
N 6 x 40/10 F (200) 513843 6 30 40 55 10 200
N 6 x 60/30 F (50) 513838 6 30 60 75 30 50
N 6 x 60/30 F (100) 513841 6 30 60 75 30 100
N 6 x 60/30 F (200) 513844 6 30 60 75 30 200
N 6 x 80/50 F (50) 513839 6 30 80 95 50 50
N 6 x 80/50 F (100) 513842 6 30 80 95 50 100
N 6 x 80/50 F (200) 513845 6 30 80 95 50 200
N 8 x 60/20 F (50) 513697 8 40 60 75 20 50
N 8 x 60/20 F (100) 513701 8 40 60 75 20 100
N 8 x 80/40 F (50) 513698 8 40 80 95 40 50
N 8 x 80/40 F (100) 513702 8 40 80 95 40 100
N 8 x 100/60 F (50) 513699 8 40 100 115 60 50
N 8 x 100/60 F (100) 513703 8 40 100 115 60 100
N 8 x 120/80 F (50) 513700 8 40 120 135 80 50
N 8 x 120/80 F (100) 513704 8 40 120 135 80 100
LOADS
Hammerfix N
Highest recommended loads1) for a single anchor.
The given loads are valid for screw nails with the specified diameter.
Type N5 N6 3) N8 N10
37
Miscellaneous Insulation fixing FID
BUILDING MATERIALS
▪ Non-plastered, pressure-resistant insu-
lating boards
▪ Plastered, pressure-resistant insulating
boards
▪ ETICS insulating boards
38
Insulation fixing FID
TECHNICAL DATA
Miscellaneous
Ø 25 mm
l
Insulation fixing FID 50 Insulation fixing FID 90
Anchor length Min. bolt pene- Wood and chip- Drive Sales unit
tration board screws
l ds
Item Art.-No. [mm] [mm] [mm] [mm] [pcs]
FID 50 048213 50 50 4,5 - 5 T40 40 50
FID 90 510971 90 90 6 6 mm / 6-kt 80 25
LOADS
Insulation fixing FID
Highest recommended loads1) for a single anchor.
The given loads are valid for chipboard screws with maximum diameter.
Type FID 50 FID 90
39
Miscellaneous Remedial wall tie VBS-M
Facing masonry
VERSIONS APPROVALS
▪ zinc-plated steel
▪ stainless steel
BUILDING MATERIALS
▪ Facing masonry with and without an
air layer
40
Remedial wall tie VBS-M
TECHNICAL DATA
Miscellaneous
Remedial wall tie VBS-M
zinc-plated stainless Max. shell Max. shell Facing mason- Drill diameter Drill hole depth Effect. ancho- Anchor length Sales unit
steel steel distance at distance at ry + cavity rage depth
115 mm facing 115 mm facing
masonry, flush masonry,
installation 20 mm sunk
installation
tfix d0 h0 hef l
Art.-No. Art.-No. [mm] [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4
VBS-M 8 x 120 514243 514236 20* — 70 8 140 >50 120 100
VBS-M 8 x 185 514244 514237 20 40 135 8 205 >50 185 100
VBS-M 8 x 205 514245 514238 40 60 155 8 225 >50 205 100
VBS-M 8 x 225 514246 514239 60 80 175 8 245 >50 225 100
VBS-M 8 x 245 514247 514240 80 100 195 8 265 >50 245 100
VBS-M 8 x 265 514248 514241 100 120 215 8 285 >50 265 100
VBS-M 8 x 285 514249 514242 120 140 235 8 305 >50 285 100
* Max. 20 mm mortar layer in the case of 50 mm thick economy facing.
The drill hole depth is to be adapted accordingly in the case of sunk installation of the anchor.
ACCESSORIES / DRILLS
SDS Plus IV 8/100/400 Masonry drill bit 8/100/400
SDS Plus II Pointer 8/400/460
Description Sales unit
Item Art.-No. [pcs]
fischer masonry drill bit with SDS fixture and short flute, ground sharp, for rotary
Masonry drill bit 8/100/400 517690 1
drilling in perforated brick and in the bed joint
SDS Plus II 8/400/460 503936 fischer hammer drill bit for drilling in concrete and in the facing brick 1
ACCESSORIES / BITS
41
Stand-off installation Thermax
VERSIONS APPROVALS
▪ zinc-plated steel
▪ stainless steel
BUILDING MATERIALS
Approved for:
▪ Concrete, cracked and non-cracked
▪ Vertically perforated brick
▪ Hollow blocks made from lightweight
concrete
▪ Perforated sand-lime brick
▪ Solid sand-lime brick
▪ Solid brick
Also suitable for:
▪ Aerated concrete
42
Stand-off installation Thermax
INSTALLATION
Miscellaneous
TECHNICAL DATA
steel steel
DIBt
Art.-No. Art.-No. [pcs]
Item gvz A4
20 M12 threaded rods, 20 anti-cold cones, 20 M12 A4 setscrews,
Thermax 12/110 M12 051291 — ▯ 20 A4 washers, 20 A4 nuts, 20 perforated sleeves 20 x 130, 5 bit, 20
5 cutting blades, 5 user manuals
10 M12-A4 threaded rods, 10 anti-cold cones, 10 M12-A4 setscrews,
Thermax 12/110 M12 — 051537 ▯ 10 A4 washers, 10 A4 nuts, 10 perforated sleeves 20 x 130, 3 bit, 10
3 cutting blades, 3 user manual
2 M12 threaded rods, 2 anti-cold cones, 2 M12 A4 setscrews, 2 A4 washers,
Thermax 12/110 M12 B 051290 — ▯ 1
2 A4 nuts, 2 perforated sleeves 20 x 130 , 1 bit, 1 cutting blade, 1 user manual
20 M16 threaded rods, 20 anti-cold cones, 20 M12 A4 setscrews,
Thermax 16/170 M12 051293 — ▯ 20 A4 washers, 20 A4 nuts, 20 perforated sleeves 20 x 200, 5 bit, 5 cutting 20
blades, 5 applicator tip extension hoses, 5 user manuals
10 M16 A4 threaded rods, 10 anti-cold cones, 10 M12-A4 setscrews,
Thermax 16/170 M12 — 051543 ▯ 10 A4 washers, 10 A4 nuts, 10 perforated sleeves 20 x 200, 3 bit, 10
3 cutting blades, 3 applicator tip extension hoses, 3 user manual
2 M16 threaded rods, 2 anti-cold cones, 2 M12 A4 setscrews, 2 A4 washers,
Thermax 16/170 M12 B 051292 — ▯ 2 A4 nuts, 2 perforated sleeves 20 x 200, 1 bit, 1 cutting blade, 1
1 applicator tip extension hose, 1 user manual
43
Stand-off installation Thermax
INSTALLATION DATA
Miscellaneous
td
hef tfix
ttol tWDVS
ETICS
Tinst
d0
Type Threaded Building Max. fixture Clamped Min. ancho- Nominal drill Drill hole depth Perforated Required Installation
rod material thickness thickness rage depth hole diameter sleeve resin quantity torque
tfix e hef do td Tinst
[mm] [mm] [mm] [mm] [mm] [Scale unit] [Nm]
Concrete/
70 14 tfix + 70 mm - 5
Thermax Solid brick
M12 60 - 1101) < 162) 20
M12/110 M12 (...) Perforated
130 20 tfix + 130 mm + 5 mm 20 x 130 26
brick
Concrete/
80 18 tfix + 80 mm - 7
Thermax Solid brick
M16 60 - 1701) < 162) 20
M16/170 M12 (...) Perforated
200 20 tfix + 200 mm + 5 mm 20 x200 40
brick
1) further usable lengths see approval
2) according to the approval the usable length up to 200 mm is possible
TECHNICAL DATA
Cleaning brush BS
44
Stand-off installation Thermax
Miscellaneous
Brush set Blow-out pump ABG
DISPENSER
Dispenser FIS DM S
LOADS
Stand-off installation Thermax 12 and 16
Highest permissible loads1) 6) for one Thermax5) in concrete and solid brick masonry8) for fixing in groups2). For the design the complete
approval Z-21.8-1837 as well as the approval of the used mortar has to be considered.
Concrete and solid brick masonry
Typ Compres- Brick type, Min. Max. in- Permis- Permissible shear load for Min. Min.
sive brick naming effective stallation sible spacing3) edge
tfix = tfix = tfix = tfix = tfix = tfix = tfix = tfix = tfix =
strength acc. DIN7) anchorage torque tensile distance
62mm5) 100mm5) 120mm5) 140mm5) 160mm5) 180mm5) 200mm5) 250mm5) 300mm5) 12)
depth load
Tinst, smin
fb [-] hef, min Nperm3) Vperm3) Vperm3) Vperm3) Vperm3) Vperm3) Vperm3) Vperm3) Vperm3) Vperm3) c (a )
max
9)
(amin) min r
[N/mm²] [-] [mm] [Nm] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [kN] [mm] [mm]
Non-cracked11) and cracked concrete14)
Thermax 12 25 C20/25 70 (72)10) 20,0 3,404) 0,88 0,49 0,31 0,21 0,16 0,11 0,08 - - 55 55
Thermax 16 25 C20/25 80 (96)10) 20,0 3,404) 1,51 0,85 0,62 0,45 0,34 0,26 0,21 0,14 0,08 65 65
Solid brick Mz
Thermax 12 12 Mz 75 20,0 1,70 0,88 0,49 0,31 0,21 0,16 0,11 0,08 - - 50 60
Thermax 16 12 Mz 75 20,0 1,70 1,51 0,85 0,62 0,45 0,34 0,26 0,21 0,14 0,08 50 60
Solid sand-lime brick and solid block KS
Thermax 12 12 KS 75 20,0 1,70 0,88 0,49 0,31 0,21 0,16 0,11 0,08 - - 50 60
Thermax 16 12 KS 75 20,0 1,70 1,51 0,85 0,62 0,45 0,34 0,26 0,21 0,14 0,08 50 60
1)
Required safety factors are considered. up to +50°C (resp. short term up to 80°C) and drillhole cleaning according approval.
2)
For single fixation see approval. 7)
For further conditions see approval.
3)
Minimum spacing while reducing the permissible load. For combinations of tensile loads, shear 8)
Masonry with satisfactory surcharge and no edge influence.
loads, bending moments as well as reduced edge distances or spacings (anchor groups) see 9)
Fixing screw M12.
approval. 10)
Values in brackets are valid for FIS PM with Powersleeve.
4)
Corresponding to the permissible tension load of the Thermax cone. 11)
The usage of FIS V is only approved for non-cracked concrete.
5)
The permissible loads refer to the Thermax with galv. threaded rod without anchor sleeve. When 12)
Only valid for masonry with satisfactory surcharge or proof against tilting. Not valid for shear
the displacement under short term load (e.g. wind load) is limited to 1mm the closing of the loads towards the free edge.
annular gap with fischer all-round sealing KD is sufficient. For measures for displacements larger 13)
No reduction of the permissible load necessary.
than 1mm see approval, chapter 3.2.4. 14)
The usage of FIS EM and FIS PM with Powersleeve is approved in cracked and non-cracked
6)
The given loads are valid for fixations in dry and humid concrete for temperatures in the substrate concrete.
45
Stand-off installation Thermax
LOADS
Miscellaneous
46
Weather facing reconctruction system FWS II
Miscellaneous
panels
VERSIONS APPROVALS
▪ stainless steel
BUILDING MATERIALS
▪ Triple-skin outer wall panels made of
concrete ≥ C12/15
47
Weather facing reconctruction system FWS II
INSTALLATION
Miscellaneous
TECHNICAL DATA
l
hef
d0
Total length Nom. drill diameter Effect. anchorage depth Anchors per cartridge Sales unit
Approval
TECHNICAL DATA
48
The information in this brochure is intended for general
guidance only and is given without engagement. Additional
information and advice on specific applications is available from
our Technical Support Team. For this however, we require a pre-
cise description of your particular application.
All the data in this brochure concerning work with our fixing
elements must be adapted to suit local conditions and the type of
materials in use.
If no detailed performance specifications are given for certain
articles and types, please contact our Technical Service
Department for advice.
Contacts
118163(7) · 06/2015 · V-MKS/MP · Printed in Germany · Subject to technical alternations without notice
www.fischer.de
Your dealer:
www.fischer.de