Q45AD9 NAMUR Series Sensor: Datasheet

This document provides information and specifications for the Q45AD9 NAMUR Series Sensor. It describes the purpose and functions of the sensor, lists available models and their performance specifications, and provides installation instructions for use in explosive environments.

Uploaded by

Engineer ajmal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
202 views10 pages

Q45AD9 NAMUR Series Sensor: Datasheet

This document provides information and specifications for the Q45AD9 NAMUR Series Sensor. It describes the purpose and functions of the sensor, lists available models and their performance specifications, and provides installation instructions for use in explosive environments.

Uploaded by

Engineer ajmal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Q45AD9 NAMUR Series Sensor

Datasheet
No revision without agency approval.
• Designed for use with approved amplifiers and intrinsically safe barriers in
explosive environments
• NAMUR compliant sensor with the rugged design and exceptional optical
performance of Q45 series sensors
• Output passes ≤ 1.2 mA in the “dark” condition and ≥ 2.1 mA in the “light”
condition
• Internal multi-turn SENSITIVITY (Gain) control accessible beneath hinged, o-ring
sealed top cover
• Models are available with an integral cable or a quick-disconnect connector
• Supply voltage: 5 to 15 V dc

WARNING: Not To Be Used for Personnel Protection


Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death.
This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output
condition.

Models
Standard 2 m (6.5 ft) cable models are listed. To order the 9 m (30 ft) cable model, add suffix "W/30" to the cabled model number
(Q459E W/30). Models with a QD connector require a mating cable (see Accessories list).

Opposed Models - Emitter (E) and Receiver (R)


Models Cable Performance Output Type

Q459E 2 m (6.5 ft)

Q459EQ 4-Pin Euro QD Constant current


880 nm, infrared
≤ 1.2 mA dark
Q45AD9R 2 m (6.5 ft) Range: 6meters (20 feet)
≥ 2.1 mA light
Q45AD9RQ 4-Pin Euro QD

Retroreflective Models
Retroreflective range is specified using one model BRT-3 P retroreflector (3-inch diameter). Actual sensing range may be more or less
than specified, depending upon the efficiency and reflective area of the retroreflector(s) in use.
Non-Polarized Models Cable Performance Output Type

Q45AD9LV 2 m (6.5 ft) Constant Current


680 nm, visible red
≤ 1.2 mA dark
Q45AD9LVQ 4-pin Euro QD Range: 9 m (30 ft) ≥ 2.1 mA light

Polarized Models Cable Performance Output Type

Q45AD9LP 2 m (6.5 ft) Constant Current


680 nm, visible red
≤ 1.2 mA dark
Q45AD9LPQ 4-pin Euro QD Range: 6 m (20 ft) ≥ 2.1 mA light

Diffuse Models
Performance curves are based on a 90% reflectance white test card.

Original Document 3 April 2017


38343 Rev. K
38343
Q45AD9 NAMUR Series Sensor

Short Range Models Cable Performance Output Type

Q45AD9D 2 m (6.5 ft) Constant Current


880 nm, infrared
Range: 300 mm (12 in) ≤ 1.2 mA dark
Q45AD9DQ 4-pin Euro QD ≥ 2.1 mA light

Long Range Models Cable Performance Output Type

Q45AD9DL 2 m (6.5 ft) 880 nm, infrared Constant Current

Range: 1 m (40 in) ≤ 1.2 mA dark


Q45AD9DLQ 4-pin Euro QD ≥ 2.1 mA light

Convergent Models
Convergent mode models operate at 680 nm, visible red. Performance curves are based on a 90% reflectance white test card.
Models Cable Focus Output Type

Q45AD9CV 2 m (6.5 ft) 38 mm (1.5 in) Constant Current


≤ 1.2 mA dark
Q45AD9CVQ 4-pin Euro QD Spot size at focus: 1.3 mm (0.05 in) ≥ 2.1 mA light

Q45AD9CV4 2 m (6.5 ft) 100 mm (4 in) Constant Current

Spot size at focus: 1.5 mm (0.06 in) ≤ 1.2 mA dark


Q45AD9CV4Q 4-pin Euro QD ≥ 2.1 mA light

Plastic Fiber Optic Models


Performance curves are based on a 90% reflectance white test card.
Models Cable Performance Output Type

Q45AD9FP 2 m (6.5 ft) 660 nm, visible red Constant Current


Range: varies by sensing mode and fiber ≤ 1.2 mA dark
Q45AD9FPQ 4-pin Euro QD optics used ≥ 2.1 mA light

Glass Fiber Optic Models


Performance curves are based on a 90% reflectance white test card.
Models Cable Performance Output Type

Q45AD9F 2 m (6.5 ft) 880 nm, infrared Constant Current


Range: varies by sensing mode and fiber ≤ 1.2 mA dark
Q45AD9FQ 4-pin Euro QD optics used ≥ 2.1 mA light

Models Cable Performance Output Type

Q45AD9FV 2 m (6.5 ft) 650 nm, visible red Constant Current


Range: varies by sensing mode and fiber ≤ 1.2 mA dark
Q45AD9FVQ 4-pin Euro QD optics used ≥ 2.1 mA light

Overview
The Q45AD9 Series NAMUR Sensor is a rugged, self-contained two-wire sensor designed for use with certified intrinsically safe switching
amplifiers and barriers (Approved Apparatus) with intrinsically safe circuits.
The Q45AD9 Series NAMUR sensor is designed in accordance with DIN 19234 (IEC/EN 60947-5-6) for operation via two-wire connection
to an Approved Apparatus controlled by the variable internal resistance of the sensor.
The sensor varies the impedance across the sensor output, which passes 1 mA or less in the "dark" condition and 2 mA or more in the
"light" condition. A highly visible red LED indicator is located beneath a raised transparent dome on top of the sensor.
• SIGNAL—LED lights red when the sensor sees its modulated light source
• POWER (Emitters only)—LED lights red when 5 to 15 V dc power is applied
Multi-turn sensitivity control on top of sensor, beneath a transparent cover, allows precise sensitivity setting (turn clockwise to increase
gain).

2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 38343 Rev. K


Q45AD9 NAMUR Series Sensor

Models are available with either a 2 m (6.5 ft) or 9 m (30 ft) long attached PVC-covered cable, or a 4-pin M12/Euro-style quick
disconnect (QD) connector. Quick disconnect models (with Q in the model number suffix) use MQD9-4.. mating cable (either straight or
right angle connector; see Accessories on page 9). Contact Banner Engineering for the availability of sensor models with 9 m (30 ft)
long attached cable.

Installation Instructions

Ex/HazLoc Applications
WARNING:
• Explosive Atmospheres/Hazardous Locations
• The user has the responsibility to ensure that all local, state, and national laws, rules, codes, or regulations
relating to the installation and use of this Banner device in any particular application are satisfied. This
Banner device must be installed by Qualified Persons, in accordance with this document and applicable
regulations.
• A Qualified Person is a person who, by possession of a recognized degree or certificate of professional
training, or who, by extensive knowledge, training and experience, has successfully demonstrated the
ability to solve problems relating to the subject matter and work.

WARNING:
• Explosion Hazard
• Do not disconnect equipment unless the power has been switched off or the area is known to be non-
hazardous.

CAUTION: Electrostatic Discharge (ESD)


Special Conditions for Safe Use. Parts of the enclosure are non-conducting and may generate an ignition-capable
level of ESD. Cleaning of the equipment shall be done only with a damp cloth.

General Notes and Conditions for Safe Use:


• See Specifications and Wiring Diagrams for important information concerning entity parameters, permissible locations,
electrical connections and certifications.
• In addition to the warning above concerning user responsibility, the installation must comply with the following:
◦ All installations must comply with all manufacturer's instructions.
◦ U.S. Installations: The relevant requirements of the National Electrical Code® (ANSI/NFPA-70 (NEC®) and when
appropriate ANSI/ISA-RP12.06.01 Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations.
◦ Canadian Installations: The relevant requirements of the Canadian Electrical Code (CSA C22.1).
◦ ATEX and IECEx Installations: The relevant requirements of EN 60079-14 and applicable National regulations.
• Do not attempt any repairs to this Banner device; it contains no field-replaceable parts or components. Tampering and/or
replacement with non-factory components may adversely affect the safe use of the system.
• Approved Apparatus entity parameters must meet the following requirements:
◦ Voc or Vt ≤ Vmax
◦ Ca ≥ Ci + Ccable
◦ Isc or It ≤ Imax
◦ La ≥ Li + Lcable
• Sensor Entity Parameters:
◦ Vmax (Ui) ≤ 15 V dc
◦ Imax (li) ≤ 60 mA
◦ Pi ≤ 225 mW
◦ Ci = 0.3 μF
◦ Li = 0 mH
• Cable Entity Parameters (if unknown):
◦ Ccable = 60 pF/ft
◦ Lcable = 0.2 µH/ft
• The ambient operating temperature range of the Sensors is −40 °C to +70 °C (−40 °F to +158 °F).
• For U.S. installations, Class II and III, Division 2 applies only to model numbers ending in a Q suffix.
• For intrinsically safe installations, sensors must be used with certified intrinsically safe switching amplifiers and barriers
(Approved Apparatus) with intrinsically safe circuits that limit supply voltage and current in the event of failures.
• Associated Apparatus is not required for installation of the devices within a Division 2 hazardous (classified) location when
installed per the National Electrical Code. The maximum voltage for Division 2 installation is 15V dc. In Division 2 installations
(without Associated Apparatus), observe Explosion Hazard warning at the beginning of this section.
• Associated Apparatus is not required for installation of the devices within a Division 2 hazardous (classified) location when
installed in, or through the wall of a suitable enclosure with provision for connection of rigid metal conduit per the Canadian
Electrical Code, as acceptable to the local inspection authority having jurisdiction. The maximum rating for Division 2
installation is 15V dc, 60 mA. In Division 2 installations (without Associated Apparatus), observe Explosion Hazard warning at
the beginning of this section.
• Maximum non-hazardous area voltage that the Approved Apparatus (intrinsically safe circuit) is connected to must not exceed
250V.

P/N 38343 Rev. K www.bannerengineering.com - Tel: +1-763-544-3164 3


Q45AD9 NAMUR Series Sensor

• Intrinsic safety ground, if required for the Associated Apparatus, shall be less than 1 ohm.
• Maximum connector torque: 6 ft-lbs.

Wiring Connections
Q45AD9 Series NUMAR sensors are intrinsically safe ONLY when used with certified intrinsically safe switching amplifiers and barriers
(Approved Apparatus) with intrinsically safe circuits. Banner does not manufacture such devices; however, our applications engineers
can refer you to suppliers of certified devices that will interface with Banner sensors.
The user is responsible for proper installation and maintenance of this equipment, and must conform with the certification
requirements relating to barriers and to maximum allowable capacitance and inductance of the field wiring. If in doubt about these
requirements, our applications engineers can refer you to the appropriate authority.
NAMUR Sensors with Attached Cable NAMUR Sensors with Quick-Disconnect

Hazardous Area Non-hazardous Area Hazardous Area Non-hazardous Area

NAMUR Sensor Approved Apparatus NAMUR Sensor Approved Apparatus

+ 1 br
+ Sensor +
Power ≤ 15 V dc 2 bu ≤ 15 V dc
br – – Input Power –
+ Sensor
bu 3
– Input
4

Output Output

Specifications for Q45 NAMUR Sensors


Supply Voltage and Current Indicators
5 to 15 V dc. Supply voltage is provided by the amplifier to which the sensor is Indicator LEDs are highly visible, located beneath a raised transparent dome on
connected. top of the sensor.
POWER (red) LED (emitters only) lights whenever 5 to 15 V dc power is applied
Adjustments
SIGNAL (red) LED lights whenever the sensor sees its modulated light source
Multi-turn sensitivity control on top of sensor, beneath a transparent o-ring
sealed cover, allows precise sensitivity setting (turn clockwise to increase gain). Connections
Output PVC-jacketed 2 m (6.5 ft) or 9 m (30 ft) cables, or 4-pin Euro-style quick-
disconnect (QD) fitting are available. QD cables are ordered separately. See
Constant current output: ≤ 1.2 mA in the “dark” condition and ≥ 2.1 mA in the Accessories.
“light” condition
Operating Conditions
Output Response Time
Temperature: −40 °C to +70 °C (−40 °F to +158 °F)
Opposed mode receiver: 2 milliseconds on/0.4 milliseconds off. All others 5 Maximum relative humidity: 90% at 50 °C (non-condensing)
milliseconds on/off (does not include amplifier response)
Certifications
Construction
Molded thermoplastic polyester housing, o-ring sealed transparent Lexan® top
cover, molded acrylic lenses, and stainless steel hardware. Q45s are designed
to withstand 1200 psi washdown. The base of cabled models has a 1/2-inch
NPS integral internal conduit thread. 1
Environmental Rating
Banner tested to NEMA 6P, IEC IP67
Application Note
Special Conditions for Safe Use: Parts of the enclosure are non-conducting and
may generate an ignition-capable level of ESD. Cleaning of the equipment must
be done only with a damp cloth. IEC IECEx FMG 14.0029X
ATEX FM12ATEX0094X
FM CoC 0003046293 (US)
FM CoC 0003046293C (CAN)

Design Standards

ATEX (European) EN 60079-0, EN 60079-11 and EN 60079-26

Canada CAN/CSA C22.2: No.0-M91, No.142-M1987, No.157-92, No.213-M1987, No.1010.1, E60079-0 and E60079-11

United States FM Class 3600, 3610, and 3810; ANSI/ISA 61010-1 (82.02.01), 60079-0 and 60079-11

IECEx IEC 60079-0, IEC 60079-11

1 Lexan® is a registered trademark of General Electric Co.

4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 38343 Rev. K


Q45AD9 NAMUR Series Sensor

Approvals

Q45AD9(a)(b), a = Sensing mode D, DL, F, FP, FV, LV, LP, CV, CV4 or R.
Q459E(b) b = Connection method Q or blank

ATEX (European) II 1 G Ex ia IIC T5 Ta = -40°C to 70°C - 38343; Entity


Entity Parameters: U i = 15 V dc, I i = 60 mA, P i = 225 mW, C i = 0.3 μF, L i = 0 mH.

Canadian IS / I,II,III / 1 / ABCDEFG / T5 Ta = -40°C to 70°C - 38343; Entity


I / 0 / Ex ia / IIC / T5 Ta = -40°C to 70° C - 38343; Entity
(Non-incendive) NI / I / 2 / ABCD / T5 Ta = -40°C to 70°C
Entity Parameters: V Max = 15 V dc, I Max = 60 mA, P i = 225 mW, C i = 0.3 μF, L i = 0 mH

United States IS / I,II,III / 1 / ABCDEFG / T5 Ta = -40°C to 70°C - 38343; Entity


I / 0 / AEx ia / IIC / T5 Ta = -40°C to 70°C - 38343; Entity
(Non-incendive) NI / I / 2 / ABCD / T5 Ta = -40°C to 70°C
S / II,III / 2 / FG* / T5 Ta = -40°C to 70°C
*Class II and III, Division 2 applies only to model numbers ending in a Q suffix.
Entity Parameters: V Max = 15 V dc, I Max = 60 mA, P i = 225 mW, C i = 0.3 μF, L i = 0 mH

IECEx Ex ia IIC T5 Ta= -40 °C to +70 °C - 35331; Entity


Entity Parameters: U i = 15 V dc, I i = 60 mA, C i = 0.3 μF, L i = 0 mH.

147291D

Performance Curves
Opposed
Excess Gain Beam Pattern
1000

E Q45AD9 E/R
X Opposed Mode
C Q45AD9 E/R
100
E 150 mm Opposed Mode 6 in

S 100 mm 4 in
S 50 mm 2 in
0 0
G 10
A 50 mm 2 in

I 100 mm 4 in
N 150 mm 6 in
1
0.1 m 1.0 m 10 m 100 m 0 1.2 m 2.4 m 3.6 m 4.8 m 6m
0.33 ft 3.3 ft 33 ft 330 ft 4 ft 8 ft 12 ft 16 ft 20 ft

DISTANCE DISTANCE

P/N 38343 Rev. K www.bannerengineering.com - Tel: +1-763-544-3164 5


Q45AD9 NAMUR Series Sensor

Retroreflective Non-Polarized Retroreflective Polarized


Excess Gain Beam Pattern Excess Gain Beam Pattern
1000 1000
Q45AD9LV Q45AD9LP
E E
X X
C Retroreflective Mode Q45AD9LV C Retroreflective Mode
100 75 mm 3.0 in
E 100 Q45AD9LP
E Retroreflective Mode 75 mm
Retroreflective
3.0 in
S 50 mm 2.0 in S 50 mm Mode 2.0 in
S 25 mm 1.0 in S 25 mm 1.0 in
With BRT-3 Reflector
0 With BRT-3 Reflector 0 0 With BRT-3 Reflector 0
G 10 G 10
25 mm 1.0 in A
A 25 mm 1.0 in
I 50 mm 2.0 in I 50 mm 2.0 in
N With BRT-3 Reflector N
75 mm 3.0 in 75 mm 3.0 in
1 1
.01 m .10 m 1.0 m 10 m 0 3m 6m 9m 12 m 15 m .01 m .10 m 1.0 m 10 m 0 1.5 m 3m 4.5 m 6m 7.5 m
.033 ft .33 ft 3.3 ft 33 ft 10 ft 20 ft 30 ft 40 ft 50 ft .033 ft .33 ft 3.3 ft 33 ft 5 ft 10 ft 15 ft 20 ft 25 ft

DISTANCE DISTANCE DISTANCE DISTANCE

Diffuse Short Range Diffuse Long Range


Excess Gain Beam Pattern Excess Gain Beam Pattern
1000 1000
Q45AD9D Q45AD9DL
E E
X Diffuse Mode X Diffuse Mode
C C Q45AD9DL
100 15 mm Q45AD9D 0.6 in 100 7.5 mm Diffuse Mode 0.3 in
E Diffuse Mode
E
S 10 mm 0.4 in S 5.0 mm 0.2 in
S 5 mm 0.2 in S 2.5 mm 0.1 in
0 0 0 0
G 10 G 10
A 5 mm 0.2 in 2.5 mm 0.1 in
A
I 10 mm 0.4 in I 5.0 mm 0.2 in
N 15 mm 0.6 in N 7.5 mm 0.3 in
1 1
1.0 mm 10 mm 100 mm 1000 mm 0 100 mm 200mm 300 mm 400 mm 500 mm 0.01 m 0.1 m 1m 10 m 0 0.3 m 0.6 m 0.9 m 1.2 m 1.5 m
0.04 in 0.4 in 4.0 in 40 in 4.0 in 8.0 in 12.0 in 16.0 in 20.0 in 0.033 ft 0.33 ft 3.3 ft 33 ft 1 ft 2 ft 3 ft 4 ft 5 ft
DISTANCE DISTANCE DISTANCE DISTANCE

Convergent (CV and CVQ Models) Convergent (CV4 and CV4Q Models)
Excess Gain Beam Pattern Excess Gain Beam Pattern
1000 1000
Q45AD9CV Q45AD9CV4
E E
X Convergent Mode X Convergent Mode
C C
100 Q45AD9CV Q45AD9CV4
E 3.8 mm 0.15 in E 100 3.8 mm 0.15 in
Convergent Mode
S 2.5 mm
Convergent Mode
0.10 in S 2.5 mm 0.10 in
S S 1.2 mm 0.05 in
1.2 mm 0.05 in
0 0
G 10 0 0
G 10
A 1.2 mm 0.05 in A 1.2 mm 0.05 in
I 2.5 mm 0.10 in I 2.5 mm 0.10 in
N 3.8 mm 0.15 in N 3.8 mm 0.15 in
1 1
1 mm 10 mm 100 mm 1000 mm 0 38 mm 75 mm 113 mm 150 mm 190 mm 1 mm 10 mm 100 mm 1000 mm 0 38 mm 75 mm 113 mm 150 mm 190 mm
.04 in .4 in 4 in 40 in 1.5 in 3.0 in 4.5 in 6.0 in 7.5 in .04 in .4 in 4 in 40 in 1.5 in 3.0 in 4.5 in 6.0 in 7.5 in
DISTANCE DISTANCE DISTANCE DISTANCE

6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 38343 Rev. K


Q45AD9 NAMUR Series Sensor

Plastic Fiber Optic (Opposed Mode) Plastic Fiber Optic (Diffuse Mode)
Excess Gain Beam Pattern Excess Gain Beam Pattern
1000
1000
Q45AD9FP
Q45AD9FP E
E
X
X Diffuse Mode
C
Opposed Mode C Q45AD9FP
Q45AD9FP 100
E 100 45 mm 1.8 in E 2.4 mm Diffuse Mode 0.09 in

S 30 mm Opposed Mode PIT46U Fibers 1.2 in S PBT46U Fiber 1.6 mm 0.06 in


S 15 mm 0.6 in
S PBT46U Fiber
0.8 mm 0.03 in
PIT46U Fibers
0 0
G 10 PIT26U Fibers G 10 0 0

A 15 mm 0.6 in A 0.8 mm 0.03 in

I PIT26U Fibers
30 mm 1.2 in I 1.6 mm 0.06 in
N 45 mm 1.8 in
N PBT26U Fiber 2.4 mm 0.09 in
1 1
1 mm 10 mm 100 mm 1000 mm 0 25 mm 50 mm 75 mm 100 mm 125 mm 0.1 mm 1 mm 10 mm 100 mm 0 10 mm 20 mm 30 mm 40 mm 50 mm
0.04 in 0.4 in 4.0 in 40 in 1.0 in 2.0 in 3.0 in 4.0 in 5.0 in 0.004 in 0.04 in 0.4 in 4 in 0.4 in 0.8 in 1.2 in 1.6 in 2.0 in

DISTANCE DISTANCE DISTANCE DISTANCE

Glass Fiber Optic, Infrared (Opposed Mode) Glass Fiber Optic, Infrared (Diffuse Mode)
Excess Gain Beam Pattern Excess Gain Beam Pattern
1000 1000
Q45AD9F Q45AD9F
E E
X Opposed Mode
X Diffuse Mode
C Opposed Mode
C
100 Q45AD9F 100 Q45AD9F
E 37.5 mm 1.5 in E 1.5 mm 0.06 in
S IT23S fibers 25.0 mm 1.0 in S 1.0 mm
Diffuse Mode
0.04 in
S 12.5 mm
IT23S Fibers
0.5 in
S
BT23S fiber 0.5 mm 0.02 in
BT23S Fiber
0 0
G 10 IT13S Fibers G 10 0 0
BT13S Fiber
A IT13S fibers 12.5 mm 0.5 in A 0.5 mm 0.02 in
I 25.0 mm 1.0 in I 1.0 mm 0.04 in
N 37.5 mm 1.5 in
N BT13S fiber 1.5 mm 0.06 in
1 1
1.0 mm 10 mm 100 mm 1000 mm 0 125 mm 250 mm 375 mm 500 mm 625 mm 1.0 mm 10 mm 100 mm 1000 mm 0 12.5 mm 25.0 mm 37.5 mm 50.0 mm 62.5 mm
0.04 in 0.4 in 4 in 40 in 5 in 10 in 15 in 20 in 25 in 0.04 in 0.4 in 4 in 40 in 0.5 in 1.0 in 1.5 in 2.0 in 2.5 in
DISTANCE DISTANCE DISTANCE DISTANCE

Glass Fiber Optic, Visible Red (Opposed Mode) Glass Fiber Optic, Visible Red (Diffuse Mode)
Excess Gain Beam Pattern Excess Gain Beam Pattern
1000 1000

E Q45AD9FV Q45AD9FV
E
X Opposed Mode X Diffuse Mode
C Q45AD9FV C Q45AD9FV
100 30 mm 1.2 in 100 3.0 mm 0.12 in
E Opposed Mode E Diffuse Mode
S 20 mm
IT23S Fibers
0.8 in S 2.0 mm 0.08 in
S IT23S Fibers 10 mm 0.4 in S 1.0 mm 0.04 in

0 0 0 BT13S Fiber 0
G 10 G 10
1.0 mm 0.04 in
A IT13S Fibers 10 mm IT13S Fibers 0.4 in
A BT13S
BT23S Fiber
I 20 mm 0.8 in I Fiber BT23S Fiber 2.0 mm 0.08 in
N 30 mm 1.2 in N 3.0 mm 0.12 in
1 1
1.0 mm 10 mm 100 mm 1000 mm 0 100 mm 150 mm 200 mm 250 mm 300 mm 1 mm 10 mm 100 mm 1000 mm 0 5 mm 10 mm 15 mm 20 mm 25 mm
0.04 in 0.4 in 4 in 40 in 4 in 6 in 8 in 10 in 12 in 0.04 in 0.4 in 4.0 in 40 in 0.2 in 0.4 in 0.6 in 0.8 in 1.0 in

DISTANCE DISTANCE DISTANCE DISTANCE

P/N 38343 Rev. K www.bannerengineering.com - Tel: +1-763-544-3164 7


Q45AD9 NAMUR Series Sensor

Dimensions
NAMUR Series Opposed, Retro, and Diffuse Sensing Modes (Model Suffix E, R, D, DL, LP, and LV)
Cabled Models Quick-Disconnect 4-pin Euro-style Models

54.1 mm
(2.13")

44.5 mm
(1.75") Lens Centerline

50.8 mm
(2.00")

69.0 mm
(2.72")

6.4 mm (0.25")
87.6 mm
(3.45") 4.5 mm (#10) Screw
Clearance (2)
7.1 mm
(0.28")

30.0 mm
(1.18")
Internal Thread
(1/2–14NPSM) ø 6.1 (0.24")
2m (6.5') Cable
External thread (M30 x 1.5)
hex nut supplied Euro- or Micro-style
15 mm (0.6") QD Connector

Convergent Sensor Models (CV and CV4) Glass Fiber Optic Models (F and FV) Plastic Fiber Optic Models (FP)

61.7 mm 60.5 mm
59.9 mm
(2.43") (2.38")
(2.36")

8 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 38343 Rev. K


Q45AD9 NAMUR Series Sensor

Accessories

Quick-Disconnect (QD) Cables


4-Pin Threaded M12/Euro-Style Cordsets (for use with NAMUR sensors)

Model Length Style Dimensions Pinout (Female)

MQD9-406 1.83 m (6 ft)


44 Typ.
MQD9-415 4.57 m (15 ft)
Straight

MQD9-430 9.14 m (30 ft) M12 x 1


ø 14.5
2
1
MQD9-406RA 1.83 m (6 ft) 3
32 Typ.
[1.26"]
4
MQD9-415RA 4.57 m (15 ft)

30 Typ. 1 = Brown
Right-Angle [1.18"] 2 = Blue
MQD9-430RA 9.14 m (30 ft)
M12 x 1
ø 14.5 [0.57"]

Replacement Lenses
Replacement Lens Assemblies
Models Description
UC-45L Replacement lens for E, R, DL and LV models
UC-45LP Replacement lens for LP
UC-45D Replacement lens for D
UC-45F Replacement lens for F and FV
UC-45FP Replacement lens for FP
UC-45C Replacement lens for CV
UC-45C4 Replacement lens for CV4
Q45 Series lens assemblies are field-replaceable.

Brackets
Mounting Brackets

SMB30C 56 SMB30SC 67
• 30 mm split clamp, black PBT • Swivel bracket with 30 mm
bracket A mounting hole for sensor B
• Black reinforced thermoplastic
• Stainless steel mounting 66
polyester 58
hardware included B
• Stainless steel mounting and
• Mounting hole for 30 mm swivel locking hardware
sensor included
29
13 A

Hole center spacing: A=ø 45 Hole center spacing: A=ø 50.8


Hole size: B=ø 27.2 Hole size: A=ø 7.0, B=ø 30.0

P/N 38343 Rev. K www.bannerengineering.com - Tel: +1-763-544-3164 9


Q45AD9 NAMUR Series Sensor

Mounting Brackets

SMB30MM SMB30UR
• 12-ga. stainless steel bracket 70 57 • 2-piece universal swivel bracket
with curved mounting slots for for limit-switch style sensors
versatile orientation • 300 series stainless steel
• Clearance for M6 (¼ in) C
• Stainless steel swivel locking
57
hardware B hardware included
• Mounting hole for 30 mm
sensor Hole center spacing: A to B=31.8, B to C=19.0, A to C=50.8, D=50.8
A
Hole size: C=6.9x32, D=73.0x6.9

Hole center spacing: A = 51, A to B = 25.4


Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1

Repairs and Translations


Obtain assistance with product repairs by contacting your local Banner Engineering Corp distributor or by calling Banner directly at (763)
544-3164. Access literature translated into your native language on the Banner website at www.bannerengineering.com or contact
Banner directly at (763) 544-3164.
Para reparaciones de productos, por favor contacte a su distribuidor local de Banner Engineering o llame a Banner directamente al (763)
544-3164. Vea la literatura traducida en su idioma en el sitio web Banner en www.bannerengineering.com o comuníquese con Banner
directamente al (763) 544-3164.
Pour vous aider lors de la réparation de produits, contactez votre distributeur Banner local our appelez directement Banner au (763)
544-3164. La documentation traduite dans votre langue est disponible sur le site internet de Banner www.bannerengineering.com ou
contactez directement Banner au (763) 544-3164.

Banner Engineering Corp. Limited Warranty


Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover
damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY
OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT
DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the
product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time.
Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:
www.bannerengineering.com.

© Banner Engineering Corp. All rights reserved

You might also like