Release Note                                                                             OmniPCX Enterprise
TC2632en-ed.06                                                                                               Release 12.3.1
              Release Note & Installation procedure for
             OmniPCX Enterprise R12.3.1 Released version
                             M4.501.14
  This is the released version of OmniPCX Enterprise release 12.3.1 with the version M4.501.14
  Due to a new Linux integration OXE R12.3 does not have an MD2 patch or even further MDs. It is replaced by that version
  R12.3.1
  R12.3.1 will have its own MDs patches.
  Technical modes for migration, new features, registered restrictions and controlled features are described in that document
  This document is based on the TC2585en-Ed05 with added information from version M4.501
  Revision History
  Edition 1: July 6, 2020             New edition for R12.3.1 / M4.501.10.f (rework of previous document from R12.3) - New
  version R12.3.1: adding features details. Adding compatibilities for AS in oxe native & GAS mode (chap. 14.4) … etc
  Edition 2: January 6,2020 R12.3.1 MD1 M4.501.11
  Edition 3: February 24,2020 R12.3.1 MD2 M4.501.12
  Edition 4: 18th of March 2020 add-on to MD2 M4.501.12.A
  Edition 5: 22th of April 2020 add-on to MD3 M4.501.13
  Edition 6: 10th of July 2020 add-on to MD4 M4.501.14
Legal notice:
www.al-enterprise.com The Alcatel-Lucent name and logo are trademarks of Nokia used under license by ALE. To view other
trademarks used by affiliated companies of ALE Holding, visit: www.al-enterprise.com/en/legal/trademarks-copyright. All other
trademarks are the property of their respective owners. The information presented is subject to change without notice. Neithe r
ALE Holding nor any of its affiliates assumes any responsibility for inaccuracies contained herein. © Copyright 20XX ALE
International, ALE USA Inc. All rights reserved in all countries.
Table of Contents
1 APPLICATION DOMAIN ............................................................................................................................ 7
2 DOCUMENTS .......................................................................................................................................... 8
3 INTRODUCTION TO RELEASE 12.3.1 ...................................................................................................... 10
   3.1 Generalities .................................................................................................................................... 10
   3.2 New hardware ................................................................................................................................ 11
   3.3 List of new features/ interoperability in R12.3/ R12.3 MD1 & R12.3.1(since TR) .................................. 11
     3.3.1 Call Handling features ............................................................................................................... 11
     3.3.2 CCS/CCD .................................................................................................................................. 12
     3.3.3 Cloud Connect .......................................................................................................................... 12
     3.3.4 Encryption ................................................................................................................................ 12
     3.3.5 Increasing provisioning level/ product limits ............................................................................... 12
     3.3.6 Infra ........................................................................................................................................ 12
     3.3.7 Interworking/ Interoperability tested .......................................................................................... 12
     3.3.8 Maintenance ............................................................................................................................. 12
     3.3.9 Mobility .................................................................................................................................... 13
     3.3.10 O2G ....................................................................................................................................... 13
     3.3.11 Rainbow ................................................................................................................................. 13
     3.3.12 Security .................................................................................................................................. 13
     3.3.13 SIP......................................................................................................................................... 13
     3.3.14 Terminals ............................................................................................................................... 13
     3.3.15 Virtualization........................................................................................................................... 13
   3.4 Features under PCS......................................................................................................................... 13
4 SOFTWARE PACKAGE & OTHER COMPONENTS ....................................................................................... 14
5 BEFORE STARTING ............................................................................................................................... 16
   5.1 Checks to perform........................................................................................................................... 16
   5.2 Getting the software ....................................................................................................................... 19
   5.3 ACTIS, eLP & software locks ............................................................................................................ 19
   5.4 Before saving the database ............................................................................................................. 20
     5.4.1 Rebuilding the database before saving ....................................................................................... 20
     5.4.2 Tickets ..................................................................................................................................... 21
     5.4.3 From crystal to GAS or vm or common hardware ........................................................................ 21
   5.5 Call Server compatibilities ................................................................................................................ 21
   5.6 Firmware upgrade ........................................................................................................................... 22
   5.7 Voice guides ................................................................................................................................... 22
     5.7.1 System voice guides ................................................................................................................. 22
     5.7.2 Alcatel 4645 voice guides .......................................................................................................... 22
   5.8 4645 .............................................................................................................................................. 24
   5.9 Recommendations about security ..................................................................................................... 24
   5.10 Translations .................................................................................................................................. 24
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14                                        TC2632en-ed.06
Copyright © ALE International 2020                                                                                                         page 2/143
  5.11 Migrating old versions ................................................................................................................... 26
  5.12 Dect ............................................................................................................................................. 26
  5.13 New installation ............................................................................................................................ 27
  5.14 Updating the PCSs ........................................................................................................................ 28
  5.15 OmniPCX 4400 migration to R12.3.1............................................................................................... 28
    5.15.1 Use of the hardware key ......................................................................................................... 28
    5.15.2 Crystal hardware compatibility with an Appliance Server............................................................ 28
6 INSTALLING THE SOFTWARE ................................................................................................................ 28
  6.1 Using dual partitioning or not........................................................................................................... 28
  6.2 Virtualization................................................................................................................................... 29
  6.3 S.O.T. ............................................................................................................................................ 29
  6.4 Installation of PCS (OXE secured or not by ssh) ................................................................................ 29
  6.5 Using the Remote Download ............................................................................................................ 29
  6.6 Secured systems ............................................................................................................................. 30
    6.6.1 Security activated by default during an installation ...................................................................... 30
    6.6.2 Installation of a secured system for VoIP encryption ("IP Touch Security" service – Thales solution)
    ........................................................................................................................................................ 30
  6.7 Reading the hardware key, CPU-id, CCS-ID ...................................................................................... 31
  6.8 Restoring Chorus/Linux data, twincpu .............................................................................................. 31
7 INSTALLING & CHECKING Actis files ...................................................................................................... 31
  7.1   Procedure ....................................................................................................................................... 31
  7.2   Checks on physical CPUs ................................................................................................................. 31
  7.3   Checks on virtualization ................................................................................................................... 32
  7.4   Checks on Cloud Connected system ................................................................................................. 32
8 CLIENT INFORMATION .......................................................................................................................... 32
  8.1 Reminder of changes appeared in Release R12.3.1 ........................................................................... 33
  8.2 Reminder of changes appeared in Release R12.3 .............................................................................. 33
  8.3 Reminder of changes appeared in Release R12.2 .............................................................................. 33
  8.4 Reminder of changes appeared in Release R12.1 .............................................................................. 33
  8.5 Reminder of changes appeared in Release R12.0 .............................................................................. 33
  8.6 Reminder of changes appeared in Release R11.2.x ........................................................................... 34
  8.7 Reminder of changes appeared in Release R11.1 .............................................................................. 34
  8.8 Reminder of changes appeared in Release R11.0.1 ........................................................................... 34
  8.9 Reminder of changes appeared in Release R11.0 .............................................................................. 34
  8.10 Reminder of changes appeared in Release 10.1.1 ........................................................................... 34
  8.11 Reminder of changes appeared in Release 10.1 .............................................................................. 34
  8.12 Reminder of changes appeared in Release 10.0 .............................................................................. 34
  8.13 Reminder of changes appeared in Release 9.1 ................................................................................ 35
  8.14 Reminder of changes appeared in Release 9.0 ................................................................................ 35
  8.15 Reminder of changes appeared in Release 8.0 and 8.0.1 ................................................................. 35
  8.16 Reminder of changes appeared in Release 7.1 ................................................................................ 35
  8.17 Reminder of changes appeared in Release 7.0 ................................................................................ 35
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14                                         TC2632en-ed.06
Copyright © ALE International 2020                                                                                                          page 3/143
  8.18   Reminder      of   changes    appeared       in Release 6.1.1 ............................................................................. 35
  8.19   Reminder      of   changes    appeared       with R4.2 ....................................................................................... 35
  8.20   Reminder      of   changes    appeared       with R4.1 ....................................................................................... 36
  8.21   Reminder      of   changes    appeared       with R3.0 ....................................................................................... 36
9 SYSTEM MANAGEMENT ......................................................................................................................... 36
  9.1 General .......................................................................................................................................... 36
  9.2 Special case of IO2N boards (CPU7s2/ CPU8) ................................................................................... 36
  9.3 Integrated WebBasedManagement................................................................................................... 37
10 COMPULSORY MINIMUM ADDITIONAL DATABASE MANAGEMENT .......................................................... 37
  10.1 Reminders .................................................................................................................................... 37
  10.2 Reminder for ABC networked sites migrating from Release < 7.x ..................................................... 38
  10.3 Important management if IO2N is present ...................................................................................... 38
  10.4 Important management with sets (noe3Gs, 8018) ........................................................................... 39
  10.5 Synchronization............................................................................................................................. 39
  10.6 Some system parameters to check ................................................................................................. 39
    10.6.1 Direct RTP .............................................................................................................................. 39
    10.6.2 Frame VoIP (Enhanced quality voice) ....................................................................................... 39
    10.6.3 Direct RTP for H323 terminals .................................................................................................. 40
    10.6.4 Inter-node protocol H323 ........................................................................................................ 40
    10.6.5 tftp (oxe) ................................................................................................................................ 40
11 STARTING UP THE CPU IN ITS ENVIRONMENT ON SITE ....................................................................... 40
  11.1   Download of couplers and sets....................................................................................................... 40
  11.2   8088 Android upgrade ................................................................................................................... 41
  11.3   SIP sets upgrade ........................................................................................................................... 41
  11.4   Moving from CPU7s1/2 to a CPU8 .................................................................................................. 41
12 CHECKING CORRECT OPERATION ........................................................................................................ 41
13 CHECKS IN A VIRTUALIZED VMWARE INFRASTRUCTURE ...................................................................... 43
14 COMPATIBILITIES/ PRODUCT LIMITS/ FEATURE LIST ........................................................................... 44
  14.1 Documents ................................................................................................................................... 44
  14.2 Status of the Version (database, Product Reports) .......................................................................... 44
  14.3 Interoperability tests status ........................................................................................................... 45
    14.3.1 OXE compatibilities in ABC network .......................................................................................... 45
    14.3.2 Open Touch ............................................................................................................................ 45
    14.3.3 OXO interop. .......................................................................................................................... 45
    14.3.4 IP sets compatibility ................................................................................................................ 45
    14.3.5 8770 ...................................................................................................................................... 45
    14.3.6 Sub-device on older sets ......................................................................................................... 46
    14.3.7 Common hardware & Crystal hardware mixed........................................................................... 46
  14.4 Appliance Servers & GAS: compatibilities ........................................................................................ 46
  14.5 UPS on A.S. & GAS ........................................................................................................................ 46
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14                                      TC2632en-ed.06
Copyright © ALE International 2020                                                                                                       page 4/143
  14.6 SIP sets, Dect sets, other sets … Latest firmware tested. ................................................................. 47
  14.7 Genesys Compact Edition .............................................................................................................. 48
15 NEW FEATURES AND NEW HARDWARE IN RELEASE 12.3 & 12.3.1 ........................................................ 48
  15.1 New hardware .............................................................................................................................. 49
    15.1.1 Set 8008G .............................................................................................................................. 49
    15.1.2 Set 8008G CE ......................................................................................................................... 49
  15.2 New features: description/explanation & management .................................................................... 49
    15.2.1 Call Handling features ............................................................................................................. 49
    15.2.2 CCD ....................................................................................................................................... 62
    15.2.3 Cloud Connect/Fleet dashboard ............................................................................................... 63
    15.2.4 Dect ....................................................................................................................................... 63
    15.2.5 Infra ...................................................................................................................................... 69
    15.2.6 Maintenance ........................................................................................................................... 70
    15.2.7 Noe & Sip sets ........................................................................................................................ 75
    15.2.8 OT ......................................................................................................................................... 76
    15.2.9 Security .................................................................................................................................. 76
    15.2.10 SIP ....................................................................................................................................... 81
    15.2.11 Terminals ............................................................................................................................. 87
16 OXE COMPONENTS ............................................................................................................................. 90
17 COUNTRIES IN WHICH RELEASE 12.3.1 IS TECHNICALLY RELEASED ..................................................... 93
18 REMARKS, RESTRICTIONS, TIPS … ...................................................................................................... 99
  18.1 ABC-F IP TRUNK GROUP ............................................................................................................... 99
  18.2 APPLICATIONS ........................................................................................................................... 100
    18.2.1 AAS (Audio Station) .............................................................................................................. 100
    18.2.2 External Voice Mail ................................................................................................................ 100
    18.2.3 LDAPs & ABC netw ................................................................................................................ 100
  18.3 BOARDS ..................................................................................................................................... 100
  18.4 CCS ............................................................................................................................................ 101
  18.5 CLIP ........................................................................................................................................... 101
  18.6 Cloud Connect ............................................................................................................................ 101
  18.7 COMMUNICATION SERVERS ........................................................................................................ 101
    18.7.1 Call Server CPU ..................................................................................................................... 101
    18.7.2 G.A.S. (Generic Appliance Server) .......................................................................................... 102
    18.7.3 UPS ...................................................................................................................................... 102
    18.7.4 Blade Center & older CPUs .................................................................................................... 103
    18.7.5 Passive Communication Server............................................................................................... 103
    18.7.6 Appliance Servers/ G.A.S. & Bill Of Material (BOM) .................................................................. 104
  18.8 DECT .......................................................................................................................................... 104
  18.9 DIRECTORY ................................................................................................................................ 105
  18.10 FSNE ........................................................................................................................................ 106
  18.11 IP CRYSTAL MEDIA GATEWAY ................................................................................................... 107
  18.12 IP TOUCH SECURITY FEATURE .................................................................................................. 108
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14                                      TC2632en-ed.06
Copyright © ALE International 2020                                                                                                       page 5/143
  18.13 MEDIA GATEWAY ...................................................................................................................... 109
    18.13.1 GD/GA boards ..................................................................................................................... 109
    18.13.2 INTIPB board ...................................................................................................................... 109
    18.13.3 Remote connection towards GD/GA/INTIP boards ................................................................. 109
    18.13.4 NGP boards (GD3/GA3/INTIP3) ............................................................................................ 110
    18.13.5 OMS (remote access & ESXi configuration rules) ................................................................... 111
  18.14 SECURITY ................................................................................................................................. 111
  18.15 SETS ........................................................................................................................................ 112
    18.15.1 8088 Noe/ Android .............................................................................................................. 112
    18.15.2 DECT .................................................................................................................................. 112
    18.15.3 IP DECT system (NEC) ........................................................................................................ 113
    18.15.4 IP Phone V1 – V1S – V2 (e-Reflexe) – Alcatel series 8 & 9 ..................................................... 114
    18.15.5 MIPT 300 & 600 handsets .................................................................................................... 114
    18.15.6 NOE3G (premium ip phones) ............................................................................................... 114
    18.15.7 NOE3G EE (Extended Edition) .............................................................................................. 114
    18.15.8 OTC Android Smartphone .................................................................................................... 114
    18.15.9 NOE sets: new reboot cause ................................................................................................ 115
    18.15.10 SIP SETS .......................................................................................................................... 115
  18.16 SIP TLS FOR EXTERNAL GATEWAY ............................................................................................. 116
  18.17 VIRTUALIZATION ...................................................................................................................... 116
    18.17.1 CONFIGURATION ................................................................................................................ 116
    18.17.2 SUMMARY ON COMPONENTS NEEDED FOR INSTALLATION ................................................... 117
    18.17.3 RESTRICTIONS ................................................................................................................... 118
    18.17.4 Virtualized attendants .......................................................................................................... 118
  18.18 VOIP ........................................................................................................................................ 118
  18.19 MISCELLANEOUS....................................................................................................................... 120
19 TECHNICAL SUPPORT........................................................................................................................ 124
20 INTEROPERABILITY with Third-Party applications ............................................................................... 124
21 README/ LIST OF FIXES ................................................................................................................... 125
  21.1   M4.501.14 R12.3.1 MD4 .............................................................................................................. 125
  21.2   M4.501.13 R12.3.1 MD3 .............................................................................................................. 128
  21.3   M4.501.12.A R12.3.1 MD2 ........................................................................................................... 133
  21.4   M4.501.12 .................................................................................................................................. 133
  21.5   M4.501.11 R12.3.1 MD1 .............................................................................................................. 138
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14                                    TC2632en-ed.06
Copyright © ALE International 2020                                                                                                     page 6/143
1 APPLICATION DOMAIN
 This document describes:
  The installation method with compatibilities & eventual warnings
  Some restrictions and remarks
  The new features brought by that release (details, management)
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 7/143
2 DOCUMENTS
Release documents & related products that can all be found on the Business Portal
OXE
OmniPCX Enterprise Release 12.3.1 presentation
  - Reference: OXE_R12_3_Rel_Pres_ENT_MLE_034239_ed01
OmniPCX Enterprise Features List and Provisioning Level Releases R10.0 - R12.3.1
  - Reference: OXE_R100-R123_FeatureList_and_ProvisioningLevel_Ed33a_ ENT_MLE_034630
OmniPCX Enterprise R12.2 & Generic Appliance Server
  - Reference: TBE063 - Pre-sales presentation introducing the Generic Appliance Server package,
      available as of OmniPCX Enterprise R12.2 (edition 01) - June 2018
OT
OpenTouch 2.5 Overview
   - Reference: TBE075
OpenTouch 2.5 - What's new - Sales overview
OpenTouch architecture and network design principles
   - Reference: TBE037 - OT architecture and network design principles - Ed05
8770 product
OmniVista 8770 R4.1 Release presentation
Virtualization
OpenTouch Suite for MLE in virtualized environment, overview
     - Reference: TBE031 - Pre-Sales presentation describing the MLE products virtualization capabilities and
         the main principles regarding license control deployment - Edition 03b, update for H1 2018 offers -
         June 2018
OpenTouch Suite for MLE virtualization design guide (Pre-Sales design guide related to the deployment in
virtualized environment of products part of OpenTouch Suite for MLE offer)
     - Reference: TBE043 - Pre-Sales design guide related to the deployment in virtualized environment of
         products part of OpenTouch Suite for MLE offer - Edition 03b, update for H2 2018 offer - December
         2018
Virtualization: OXE configuration related to OXE releases and ESXi infrastructure versions
     - TC2431: Technical Communication from Technical Support L3.
Other
EF-Phase-In-C139-EN - Phase-in and Pricing | OpenTouch Suite for Mid- and Large-sized Enterprises
Cross Compatibility. This document covers compatibility between OpenTouch Suite software releases and
applications.
    - Reference: MLE_CrossCompatibility_April_2019_Ed35_ENT_MLE_034190
Release phase-out policy
     - Reference: MLV_ReleasePolicy_PhaseOutProduct_April_2019_Ed43a_ENT_MLE_034198.xlsx
H1 2019 OpenTouch Suite for MLE Offer Release Management - Actis/eBuy Rules
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 8/143
    - Reference: ENT_MLE_033785 - Ed.04: March 6th, 2019
Hardware / Applications Compatibilities
        TC0418 Ed. 19
S.O.T. release note
    - TC2456 Release Note for S.O.T (Software Orchestration Tool) version R2.1 (2.1.004.008)
System documentation
OmniPCX Enterprise R12.3.1 Documentation note
OXE R12.3.1 Documentation package (All languages)
   - Reference: OXE_R12.3.1_DocumentationPackage_8AL90168ENAK_1_en
8770 R4.1 Documentation package (All languages) + Documentation Note Omnivista 8770 4.1
8770 R4.1 Release note
   - Reference: TC2571en
Related Technical Communications
Note: Most of the old technical communications are not mentioned anymore. Refer to previous release notes
same section if needed.
New management in OXE R12.3:
“List of parameters and system options added in M4, M3, M2, M1 and L2__3BA_29000_0536_DPZZA.xls”
TC2517 Release Note for 4059 EE 2.1 on OmniPCX Enterprise + A4059EE 2.1.0.5 changelog
TC2515en-Ed01_Warning_OMS_Suse_SP3
TC2481-RN for Base Station 8378 DECT IP-xBS Release R100
TC2462en-Ed05_OXE_configuration_guide_for_Rainbow_PBX_Integration.pdf
TC2308 Technical Release Notes For 8028S, 8058S, 8068S, 8078S Premium Deskphones
TC2181en-Ed14_Release_Note_for_8088_Smart_DeskPhone_Release_302_in_Business_mode
TC2347en-Ed04_Technical Release Notes For 8088 R301 Smart Deskphone
TC2431en-Ed01_Virtualization Configuration of OXE following releases and ESXi infra version
TC2312 Ed03: “OXE mgr Configurations Management Evolution”. This document describes the new
parameters and the modified parameters introduced in all the releases starting from k1.520 (TC to be released
soon)
TC1854en-Ed25_OmniPCX_Enterprise_patch_aligment_procedure.xlsm
TC1897 installation AS HP DL320E G8v2
TC1868 Multicodec evolutions in OXE Release 11.0: Database translation
TC1708 Installing and using the OmniPCX Enterprise PC Installer Software (with compatibility information)
TC1854 OXE patch alignment (patches alignment + database translation table)
TC1271 Checks for integrity and authenticity of downloaded software
TC1255 4008 / 4018 SIP set deployment with OmniPCX Enterprise
TC0779 Synchronization of the system after migration to OmniPCX Enterprise with Appliance Server
TC0778 Migration OmniPCX 4400 to OmniPCX Enterprise
TC2400 PCS upgrade to R12.x improvement
TC2338 R12 Remote installation of PCS
TC1676 messages CONNECT, management Burst size & Burst delay
TC2431 Virtualization: Configuration of OXE following releases and ESXi infra version
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 9/143
          Remote worker sip sets on internet/noe on vpn:
          Server_deployment_guide_for_remote_workers_8AL90345ENAAEd:08
          Phase-in products
          E-Flash phase-in EF-Phase-in-C114 – announce of a new MLE offer: the Alcatel-Lucent OmniPCX® Enterprise
          Communication Server release 12.3
          Phase-out products
          Always check for latest phase-out products on the Business Portal (EF-Phase-out)
          3 INTRODUCTION TO RELEASE 12.3.1
          3.1 Generalities
          In this document, you will find the steps necessary for installing version M4.501 for:
           a new installation,
           evolution from the releases R5.0 Lx, R5.x, R6.x, R7.x, R8.x, R9.x, R10.0, R10.1, R11.0, R11.0.1, R11.1,
              R11.2.x, R12.0, R12.1, R12.2 & R12.3.1
           a migration from OmniPCX 4400 to OmniPCX Enterprise R12.3.1
          Plus, the description of the new 12.3 & 12.3.1 features restrictions, features to come & misc. information.
          Release R12.3.1 is a version with NO change of software locks. See chap. 5.3
          Same Commercial Items of Software Release R12.3:
                3BA09005KA - SOFTWARE LICENSE ENTERPRISE R12.3
                3BA27860AE- OMNIPCX ENTERPRISE R12.3 DVD-R
                3BA27861AE- OMNIPCX ENTERPRISE R12.3 SECURED DVD-R
                3BA27870AE- OXE GENERIC AS R12.3 DVD-R SW MEDIA KIT
                3BA50280AE - OMNIPCX ENTERPRISE RELEASE R12.3
Warning    Release R12.3.1 needs CCS version 10.10.93.01 – otherwise CCS will not connect to OXE R12.3.1 !!
          OmniPCX Enterprise - Release 12.3.1
          Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
          Copyright © ALE International 2020                                                                   page 10/143
Status of the Version:
Patch M450114 - MAO DB software version: M45014
        Patch                         Patches Aligned                       DB version Compatible till
         j2.5                            j2.501.23                                   j2.501.21
          j2                             j2.603.38                                   j2.603.38
          k1                             k1.400.37                                   k1.400.35
         k1.5                            k1.520.47                                   k1.520.43
          l1                             l1.301.42                                   l1.301.41
          l2                             l2.300.43                                   l2.300.43
         m1                              m1.403.27                                   m1.403.26
         m2                              m2.300.29                                   m2.300.25
         m3                              m3.402.32                                   m3.402.26
3.2 New hardware
   sets CLOUD EDITION: only a software difference
   8008G (Gb edition)
3.3 List of new features/ interoperability in R12.3/ R12.3 MD1 & R12.3.1(since
    TR)
see details in chap. 15 NEW FEATURES AND NEW HARDWARE IN RELEASE 12.3/ 12.3.1
3.3.1 Call Handling features
   Greeting Guide when calling a hunt group
   Huntgroup should take care of "busy camp-on" setting of user in multiline configuration
   Disable Oxe phonebook ldap overflow when 4059ee performs a cbn query
   OXE CSTA: generate the private event when user is added in a Hunting Group
   OXE LDAP overflow using LDAPS
   OMS and PCS interworking support
   Voice flow duplication for IP DR Link (R12.3.1)
   filtering of OXE events sent to 8770
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 11/143
   DR link and IP DR-link request for VG play on OXE for OPR (R12.3.1)
   Synchronization of OXE MWI (Message Warning Indicator) and advanced call-log (R12.3.1)
3.3.2 CCS/CCD
   Protocol adaptation: need of a new CCS version 10.10.93.01
   Extension of PERCC-39
   Log of abandoned CC calls while queuing or ringing
   OXE Integrated Call Log also for CCD agents
   Support of 8019 - Leftovers (Add of proACD feature)
   Redirecting Info on SIP public trunk for Contact Center (R12.3.1)
3.3.3 Cloud Connect
   Remote console (maintenance/management) offered through the Fleet Dashboard: NOT RELEASED. In a
    future version.
3.3.4 Encryption
   Native Encryption - Scalability up to 15k (new virtual machine: External Encryption gateway)
   Native Encryption - SIP Trunk TLS for installed base with Thales
   Native Encryption in ABCF network
   Ipdsp available in native encryption solution (MD1). Minimum version is 11.2.0
   Migration from secured SSM boxes to FSNE (Full Software Native Encryption): explanatory document to be
    published as a Technical Communication. No OXE development.
3.3.5 Increasing provisioning level/ product limits
   Nothing new
3.3.6 Infra
   Support of VMware Release R6.7
   Support of Hyper-V (MD1)
3.3.7 Interworking/ Interoperability tested
   OT 2.4 & new OT 2.5
   8770 R4.1
3.3.8 Maintenance
   Syslog server for dect xBS.
   3 new tools to check DNS resolution: "nslookup, host & dig" (R12.3.1)
    New OXE editor friendlier then “vi”: “nano” (R12.3.1)
    Check for manpages & other internet Linux sites for more information & usage related to those new
        integrated tools
   RAINBOW/CC – tools to check DNS resolution: "nslookup, host,dig" (R12.3.1)
   Tool to check encryption data coherency ("cryptcheck")
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 12/143
3.3.9 Mobility
   SUOTA (on all base stations)
   Campus (IBS, RBS with new xBS)
3.3.10 O2G
   No OXE development
3.3.11 Rainbow
   No OXE development
3.3.12 Security
   INFRA – vulnerability fixes (Meltdown/ Spectre) through a new kernel (R12.3.1)
   Support of VMware encryption and VMware motion with OXE-V
   Hashing of administrator passwords using SHA2 instead of MD5 (MD1)
3.3.13 SIP
   support TLS 1.2 and certificates of 4096 bits for SIP Trunk natively while allowing other devices to work
    with existing SSM boxes solution
   Advice of Charge (AOC) on SIP trunk (R12.3.1)
   SIP trunk: filtering of the OXE calling name (R12.3.1)
   SIP trunk recording (R12.3.1)
3.3.14 Terminals
   8008/8018/8028s SIP phone on Internet through OTSBC and native encryption
   Noe release R500 (R12.3) & R510 (R12.3.1 from patch “F”) including Super Wideband audio "step 2" for
    NOE 3G EE sets & use of desk-phone as a USB speakerphone for a computer (R12.3.1)
   8008G CE set (Cloud Edition – 8008 as sip only, no noe possibility)
3.3.15 Virtualization
   Support of VMware encryption and VMware motion with OXE-V
3.4 Features under PCS
   No features under PCS
PCS = Premium Customer Support. The Premium Customer Support process allows the Partner Businesses to
profit of an assistance on features or products whose marketing was announced (DR3) but which are not
launched yet on the market. The PCS process replaces the SDP (Specific Deal Process) previous process; refer
to the eFlash EF_Marketing_003_260704.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 13/143
       4 SOFTWARE PACKAGE & OTHER COMPONENTS
       The software package contains the OmniPCX Enterprise R12.3.1 MD4
       Delivery from factory:
            M4.501.14
                  - Full version M4.501
                  - Static patch M4.501.14
                  - Secured patch SM4.501.14
       The Generic Appliance Server software is based on factory version & consists in:
       SWS version : 6.17
       OXE Version : m4.501.14
       OMS Version : 9.06
       FlexLM Version : 11.16.5.0-006.104-IP0002
       BootDVD version used for OMS VM : 12.3.022.000
       This OXE SW Server is compatible with Bootdvd Version : 12.3.022.000
       Delivery at the Business Partner Web Site:
       It I STRONGLY recommended to check on the Business Portal if a new dynamic patch is present to take
       advantage of the latest fixes.
Note    The access to secured patch is only given on request after filing the appropriate document posted on
        Business Portal Customer Support > Technical Support > Software download > OmniPCX Enterprise >
        OmniPCX Enterprise > All Release > Request for Security Patch Access.
        For systems using Full Software Native Encryption, secured patch MUST NOT be installed
       Other:
       Memory bank for CPU7s2 (ONLY for releases from R12.0): orderable item is 3BA27056AC (SDRAM 512MB for
       CPU7-2)
              Product/ Component                  Reference or type                            Misc
       OMNIPCX ENTERPRISE R12.3.1                       OXE              System documentation is available on the
       Version M4.501.14                                                 Business Portal, in the section Technical
                                                                         Support\ Technical Documentation Library
       OmniPCX Enterprise - Release 12.3.1
       Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
       Copyright © ALE International 2020                                                                   page 14/143
       OMNIPCX ENTERPRISE R12.3.1                         OXE            Use ONLY for secured systems with SSM/MSM
       Secured Version SM4.501.14                                        boxes
       vmFlex-2.1.100.019 for CentOS 7 if            vmflex centOS       vmFlex-2.1.100.019
       ESXi release is 5.5 or above                                      esxi >= 5.5
       or
       vmFlex-CentOs5-2.1.000.093 for                                    Esxi < 5.5
       CentOS5 if ESXi release is lower than
       5.5
       vmFlex-CentOs5-2.1.000.093 for KVM                                KVM
       OST                                       ipv4/v6 translator/     OST.iso 5.18 (iso), to be used with bootDVD
       - OXE IPV6-IPV4 translator                EEGW                    12.3.016.000 minimum
       - OXE External Encryption Gateway                                 See NOTE hereafter
       OXE MS APPLICATION DVD-R                           OMS            OXE binary 8.03 (updated along with the OXE
       Software Version 9.06                                             patches) minimum version
                                                                         To be used with bootDVD Suse SP3 bootdvd-
                                                                         bootdvd-12.3.022.000-x86_64
       GAS/ OXE Software Server                   GAS/ Oxe Software      OXE SW Server 6.17 (oxe version M4.501.14),
                                                       Server            to be used with bootDVD Suse SP3 bootdvd-
                                                                         12.3.022.000-x86_64
       OmniVista 8770 R4.1 Software                                      At technical release : OmniVista 8770
       (technical released version               OmniVista 8770          8770.4.1.10.00 + patches
       8770.4.1.10.00) including patches A-F                             System documentation is available on the
       at Technical Release date                                         Business Portal, in the section Technical
                                                                         Support\ Technical Documentation Library
       O2G                                         O2G R1.0 DVD-R        Technical Release version 14.0.000.035
                                                    SW MEDIA KIT
       Before installing any software, we strongly advise you to check the integrity and authenticity of the software.
       For detailed information about checksums, please refer to the technical communication TC1271 Checks for
       integrity and authenticity of downloaded software.
       (*)      That Sip DM is not usable for 8002/8012 sets in hotel environment
Note    PSP software (Phone Set Programming) is not delivered with the R12.1 DVDs.
        PSP software is available on Business Portal (https://businessportal2.alcatel-lucent.com) in section
        Customer Support > Technical Support > Software Download > OmniPCX Enterprise > OmniPCX Enterprise
        > All Releases. This version is compatible with OmniPCX Enterprise RELEASE 12.1
        Component OST:
        “OST” is a component that is a merge of OST64 (ipv6/4 translator) & new External Encryption Gateway.
        Version 5.13 correspond to the version of OST65.
        OST64 & Eegw cannot be started simultaneously. Eegw is installed by SOT version 2.1 step1: choice to
        start ost64 or eegw has to be done at installation time.
       OmniPCX Enterprise - Release 12.3.1
       Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
       Copyright © ALE International 2020                                                                   page 15/143
List of binaries in all different versions of version M4.501.14
Version of all components is in chapter 16 - OXE Components.
5 BEFORE STARTING
5.1 Checks to perform
    Compatibilities/ Product Limits
Consult document about CROSS-COMPATIBILITY/ PRODUCT LIMITS (see chap. 2 DOCUMENTS)
    Hardware: phased-out boards
Check for phase-out boards in the Alcatel-Lucent business portal documents (Eflash Phase out) or in the
Technical Knowledge Center database (Applications/ Hardware/ Terminals Cross compatibility)
    Conditions for installation in ABC network
Conditions for Installation of RELEASE 12.3.1 in network is detailed in the last “MLE CrossCompatibility”
document available on Business Portal.
     Reminder on applications & functionalities
The table below shows all the applications and functionalities which are no more longer provided by OmniPCX
Enterprise R12.3.1, whatever hardware used.
                                                                      Compulsory
                                                                       deletion/
    Family        Type of application           Migration to                              Documentation
                                                                  modification before
                                                                  migrating to R12.3
47xx            OmniVista 4760i           “mgr” or OmniVista 8770 Yes                 System Documentation
                                          or WBM (from R12.0)
                4715, 4730, 4740 or       OmniVista 8770          No                  TC1479
                4740 PTP
                4730i                     mgr or OmniVista 8770      Not applicable       System Documentation
                4755                      OmniVista 8770             No                   TCV010
                4000 Directory Server     8770 LDAP Server                                TCV017
                Directory PC Client for   8770 Directory Client                           TC1479
                4755/4000
Voice mail      4630, 4620 or VPS35       4645 or OT MediaCenter
systems         4635 VPCPU, 4635 or
                VPCPU-1
ACT migration 4300, 2600, 4600 or         Manage the equipment in Yes                     No
              5400                        a new crystal ACT or
                                          common hw rack
ACD-V1          ACD-V1                    CCD or OTCCSE              Yes                  TC0487 (CCD)
                4735 & 4736               CCS
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 16/143
                                                                         Compulsory
                                                                          deletion/
      Family         Type of application          Migration to                              Documentation
                                                                     modification before
                                                                     migrating to R12.3
                 4961 first party TAPI      No migration – Not       Not applicable      No
                 middleware                 supported
                 4973 Telephony             Not supported (Replaced Not applicable
                 Assistant                  by OmniTouch UC My
                                            Phone)
CCS              ccs                        Ccs version evolution   UPGRADE to
                                                                    version
                                                                    10.10.93.01 !!
VoWLAN           VoWLAN R1.x                VoWLAN R5.x             No                    TC1596
Others           Alcatel Unified            OTMC                    Not applicable
                 Messaging
                 Daughter board SPB         Moxa box IP/V24 module No                     System Documentation
                 Overflow on QoS            Not supported          No                     No
                 (VoIP)
                 CPU2, CPU3,                Replaced by              No                   No
                 CPU5 Step1/Step2/          CPU7-2 – with 512 MB
                 Step3, CPU6, CPU7s1,       memory change or CS-2
                 All Appl. Servers except   or Appliance Server or
                 Lenovo M6 & HP             vmWare virtualisation
                 G8v1/v2                    (depends on the Actis
                                            configuration)
                                            or new cpus CS-3/CPU8
                 LIOE & TSC-LIOE            INTIP3                   Yes                  No
                 INT1/INT2                  INTOF-2                  Yes                  No
     Applications and functionalities dependent on CPUs and hardware platform used
Depending on the type of CPU (crystal CPU, Appliance Server, Call Server in rack, virtualization) and the
hardware platform used (Crystal, common hardware), some applications or functionalities are not authorized.
                                                                           Appliance Server or virtualization
                                           Crystal CPU   Call Server
                                                                           Common
                                            (7s2 or 8)    (CS-2/3)                       Crystal hardware
                                                                           hardware
Voice mail     4645                      No              Yes              Yes          No
               4615 / VMU-OBCA           Yes             No               No           No
               4615/VMU-OBCA2            (only CPU6)
               (1)
Various        Campus DECT               Yes             No               No            No (4)
               DTM for DECT on           Yes             No              No           No  DECT8 (2)
               CPU6                                      DECT8            DECT8
               VG on CPU6                Yes             No               No            No  GPA2 (2)
               DTMF                      Yes             No               No            No  GPA2 (2)
                                         (on CPU6 &
                                         CPU7)
               V24                       Yes             No               No            No  V24-IP module (3)
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 17/143
                                                                                   Appliance Server or virtualization
                                                 Crystal CPU       Call Server
                                                                                   Common
                                                  (7s2 or 8)        (CS-2/3)                     Crystal hardware
                                                                                   hardware
                       Music on hold on         Yes               Yes             No  Z port No  Z port (3)
                       CPU
                       IO2/OBCA (5)             Yes               No              No              No (5)
                                                (only with
                                                CPU6)
                       IO2N                     Yes               No              No              No (5)
                       SPB                      No  IO2          No              No              No  V24-IP module (3)
                       3 ACT levels             Yes               No              No              No (3)
                       eRMA                     No                Yes             Yes             No
          (2) Replacement is carried out by Actis.
          The DECT8 board is not compatible with DECT2/DECT4 boards. If DECT2/DECT4 boards are present, ACTIS
          will replace them.
Warning    REMINDER
           DECT2/DECT4 and DECT4 HB boards are phase-out. They are still supported by RELEASE 12.3.1 but can no
           more be configured for addition or for new installation.
           They are NOT compatible with SUOTA functionality
          (3) Manual modifications are required.
          (4) No alternative possible.
          (5) Boards of IO2/OBCA type do not exist in common hardware. A certain number of applications and
          functionalities are therefore no more supported, such as:
                  Extension of V24 physical ports via SPB board => use the Moxa box
                  Direct management of data applications in V120 accessible from a terminal adapter (TA in V120)
                       locally or from the outside (appli login, SLIP, hotel management, etc.).
           Data transmission in the B channel of a digital support (T2, PCM, etc.)
                  Link in a B channel of a T2 (switched or not switched)
                  Link in a B channel of a PCM board (often encountered in South America where T2s are less
                       common)
                  Link via TA/Modems
                  No more back-up signaling via ISDN
                  X25 in a B channel (Tunnel operation in T2 and Centrex operation for centralized network
                       management via 4740)
                  Frame Relay in the case of saturation of the signaling channel in D
                 In this case, the Tunnel, Broadcast and network incident type X25 applications pass through a B
                 channel (application of over-reservation coefficient 15 in the D channel of a link allows Frame Relay not
                 to be carried out, but the mechanism still exists).
                 Installation on second partition
          OmniPCX Enterprise - Release 12.3.1
          Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
          Copyright © ALE International 2020                                                                   page 18/143
Coming from ANY version <12.0 the cpu MUST be reformatted: no possible use of unactive
partition (partitions are resized + multipartition process NOK). Coming from R12.0 second
partition installation can be used
      VoIP network conformity check
The OmniPCX Enterprise R12.3.1 is a native IP product when using a dedicated cpu hardware or virtualization
and in the case of hardware mixing. All signaling exchanged between the Call Server and the Media Gateways
or ACT Media Gateways is transported over IP. It guarantees a reliable IP connection and respects the VoIP
criteria (delay, jitter, packet loss) for VoIP configurations.
VoIP conformity tests are compulsory before deploying the VoIP solution; consult the VoIP
Engineering section on Business Portal for the methodology, recommendations and tools to
secure the VoIP installation. In particular, the VoIP Assessment tool for VoIP Audit and
diagnostic help guide are strongly recommended (available in the Brest training catalog).
CAUTION
With the "Modem, Fax, Data transparency over IP" feature, it is mandatory that the IP network is almost
perfect; see technical communication TC0712 Modem, Fax, Data transparency over IP.
5.2 Getting the software
Virtualization requires extra DVDs or tools like Operating Systems, firmwares …
Virtualized OXE:
      ESXi boot DVD or Suse boot DVD (for the KVM solution)
Flex server:
      OVF file (image of CentOS OpSyst + Flex server binary: vmware solution) or separate CentOS ISO
         image + flex server binary (for the KVM solution)
OMS:
      Boot DVD, OXE MS APPLICATION DVD-R
S.O.T.:
      S.O.T. v2.2 or upper plus vmware player (free download & use) or workstation on a user PC.
         Download S.O.T. on the BPWS at product versions level. Some virtualization features may require
         extra virtualization software or licenses.
      S.O.T. 2.2 is needed if PCS cpus have to be reinstalled (for systems coming from releases lower than
         12.0)
Note: ALEDS & PC Installer tools are no more supported & are replaced by S.O.T.
5.3 ACTIS, eLP & software locks
Release 12.3.1 does NOT need a change in software locks (use of swk of release 12.3) Actis 22.5 is requested
     Oxe version lock: lock 165: value 48
     Oxe Beta lock 87: value 28
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 19/143
       NEW SIP TRUNK RECORDING: 428
Product catalogue OXE: E33-Ed42
Full Software Native Encryption & Full Software Native Encryption on ABC network need software lock 424 (set
to the value of the number of ip phones).
To prepare any system to the Cloud connection a new CC-suite id is inserted by eLP or Actis. This data stands
before the CPUids in the swk file constitution.
CAUTION
An add-on via Actis is only possible if the current Actis offer includes the “. swk” file (generated by eLP then
imported into Actis).
When you make a configuration request four or five OPS files will be generated:
         <offer_id>.zip
         <offer_id>.swk (this file results from the eLP)
         <offer_id>.hw
         hardware.mao
         <offer_id>.sw8770 (if 8770 is present)
In the case of the migration of an OmniPCX 4400, the lock files of the site (photoconfig) should be put in
Actis. Actis will then allow you migrating these locks (in "Migration to OXE" Offer) by proposing migration
packages for the functionalities and hardware that are not supported by R12.3
NEW LOCKS in R12.3
Lock 428: SIP TRUNK RECORDING
5.4 Before saving the database
The following operation may be necessary coming from an old release:
In the current version, carry out the following commands.
5.4.1 Rebuilding the database before saving
Login:                  mtcl
Directory:              /DHS3data/mao
Command:                /DHS3bin/fab/fichges recover all (if R  1.5.2)
                        fichges force_recover_dico       (if R > 1.5.2)
This operation may be long (over 30mn depending on the database & cpu type) and it is essential not to
interrupt it while running.
Carry out the back-up in swinst and transfer it to disk or PC.
CAUTION
 Do not choose the save option "Save for rebuilt" (index files will not be saved).
 Do not use a database saved in "Automatic save" (same reason).
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 20/143
          5.4.2 Tickets
          REMARKS: On the saving of charging tickets.
          Sites going from A9.5xx to R12.3.1 who wants to retain client tickets (hotel or hospital type) in the
          ‘TABJUSTIF’ files should "empty" the administrative tickets before saving as these are no more processed as of
          R3.0. As of R3.0, administrative tickets are stored in compressed files.
          Sites going from R1.5.2 to R12.3.1 which already have compressed files should save them as they will be
          compatible.
          5.4.3 From crystal to GAS or vm or common hardware
          CAUTION:
          The shelves already created in position 18 and 19 must be moved before the translation. If this is not done,
          they will not start. When migrating to OXE R12.2 with change of CPU 4400 by a VM or a CS or GAS, there is
          an automatic translation of shelves created in these 2 positions. This automatic translation does not exist if the
          CPU of type 4400 is retained.
          5.5 Call Server compatibilities
Warning    FOLLOW CAREFULY THE RULES OF THIS SUB-CHAPTER (same rules as those from R12.0)
          Only the following CPUs are compatible:
               CPU7s2 with a change of memory bank to 512Mb. To obtain this memory bank:
                        Automatically added during a R12.0 or upper upgrade by Actis
                        Can be ordered separately in Actis
               CPU8
               CS-2
               CS-3
               Appliance servers to be used now in GAS mode only for new installations
                       - Check for compatibility with Suse 12.3 & KVM (white lists manufacturer)
                       - Memory: 4GB minimum (1 oxe vm, 1 OMS)
               VM with following characteristics
                       - Memory size from 1Gb to 2Gb
                       - OS: other Linux or CentOS
                       - Hard drive size: 40Gb minimum
                       - Network card:
                              - E1000
                              - VMNETX3 IF CentOS is selected
                       - S.O.T. R2.1 will generate vm with following characteristics:
                               500 Users – 1 vCPU – 1024 MB RAM – 40 GB disk
                               3000 users – 1 vCPU – 1024 MB RAM – 60 GB disk
                               7000 users – 1 vCPU – 1024 MB RAM – 80 GB disk
                               15000 users – 1 vCPU – 2048 MB RAM – 80 GB disk
          OmniPCX Enterprise - Release 12.3.1
          Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
          Copyright © ALE International 2020                                                                   page 21/143
!! The CPUs not mentioned above ARE NOT compatible and most of them will not be able to be installed
For installing a CPU7s2 the bios must be at a minimum version. Follow the chapter 19.2.2
Thus the menu “boot Alizee” is no more available to load this cpu => use the “A4400” boot method.
Coming from any version up to M1.401.x (included) the disk must be reformatted meaning that remote
download feature cannot be used to go to M1/2/3/4.
This concerns main & standby CPUs as well as PCS cpus.
From M1.403.x to any other version remote download is operational.
A system running in L2 for instance can remote load & install a M4 to a cpu already installed in M1 or above
5.6 Firmware upgrade
Going from any version up to this release: iptouch sets will upgrade their firmware. Take this time into account
before upgrading. Chapter 5 shows all the components & firmware versions (in bold: new).
8088 Android sets will do the upgrade on the Cloud if correct management is performed (see dedicated
chapter on system documentation/ terminals
5.7 Voice guides
Ensure that you have the voice guides required in RELEASE 12.3.1 (no change from previous version)
5.7.1 System voice guides
The version of system voice guides compatible with the OmniPCX Enterprise R12.3.1 is v5.3 CD-ROM
reference: 3BA 57423 AAAG
The following files are provided on the CD-ROM:
 Voice guide transfer tool.
 Business generic voice guides in language 1.
 Business standard voice guides in language 1.
 Hotel generic voice guides in languages 2&3.
 Hotel standard voice guides in languages 2&3.
 Alcatel music on hold.
 Voice guide documentation.
They can be downloaded from the Business Portal section Customer Support > Technical Support > Software
Download > OmniPCX Enterprise > All releases.
5.7.2 Alcatel 4645 voice guides
The version of the Alcatel 4645 voice guides is v1.10. CD-ROM reference: 3BA 27588 AAAH
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 22/143
Version details:
09          07.16.10     e-Va voice guides CD-ROM – v1.8
                         Corrected fault reports:
                         crms00197618 – New voice prompts 1071, 1091, 1608,
                         1626, 1628 & 1646 in Cantonese
10          12.28.12     e-Va voice guides CD-ROM – v1.9
                         New Swedish voice prompts.
                         Add of Hebrew language.
11          06.27.16     e-Va voice guides CD-ROM – v1.10
                         New voice prompt 1911 “Your account is locked” in all
                         languages
The following files are provided on the CD-ROM:
 Voice guide transfer tool.
 Voice guides in 40 languages in law A.
 Voice guides in 20 languages in law .
 Voice guide documentation.
They can be downloaded from the Business Portal section: Customer Support > Technical Support > Software
Download > OmniPCX Enterprise > 4645.
The following languages are available:
            Country                           Code                      Law A                     Law µ
Arabic female                                 AR1                         x
Arabic male                                   AR0                         x
Cantonese                                     CA0                         x                         x
Catalan                                       ES1                         x
Croat                                         HR0                         x
Czech                                         CS0                         x
Danish                                        DA0                         x
Dutch                                         NL0                         x                         x
English                                       EN0                         x                         x
English Australia                             AS0                         x
English United States                         US0                         x                         x
Finnish                                        FI0                        x                         x
Flemish                                       NL1                         x
French                                        FR0                         x
French Canada                                 FR2                         x                         x
German                                        DE0                         x                         x
Greek                                         GR0                         x
Hungarian                                     HU0                         x
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 23/143
            Country                           Code                      Law A                     Law µ
Icelandic                                      IS0                        x
Italian                                        IT0                        x                         x
Japanese                                       JP0                        x                         x
Korean                                        KR0                         x                         x
Latvian                                       LV0                         x
Lithuanian                                     LT0                        x
Mandarin China                                CN0                         x                         x
Mandarin Taiwan                               CN1                         x                         x
Norwegian                                     NO0                         x                         x
Polish                                         PL0                        x                         x
Portuguese                                    PT0                         x                         x
Portuguese Brazil                             PT1                         x                         x
Romanian                                      RO0                         x
Russian                                       RU0                         x                         x
Slovak                                        SK0                         x
Slovenian                                      SI0                        x
Spanish                                       ES0                         x
Spanish United States                         ES2                         x                         x
Spanish Latin America                         ES3                         x                         x
Swedish                                       SV0                         x                         x
Turkish                                       TR0                         x
5.8 4645
Issue is detected in case of backing up/restoring big files bigger than 2Gb (crqms00177881): the file does not
have the right size (issue related in both os & client tool).
the size of /tmpd (usr4) increased to 25 GB. This change will reflect only for HD size >=80 GB. For other disk
size, there is no change.
5.9 Recommendations about security
The security rules and recommendations for securing the access and using the system are described in the
System Documentation "Security" section.
The IP services and port numbers used by the system are also available in this section.
It is strongly advised to have full network security managed & change regularly the account passwords.
Consult also the security news alerts.
You can use the embedded oxe tool “securitystatustool” to perform a check of the OXE. Those controls are
described at chapter 15 in the release note OXE R12.2
5.10 Translations
DO NOT USE THE “mao for rebuild” type of database backup to translate to a release <R12 to R12.0: the
rebuild tool always included in that backup is NOT compatible with the new Linux OS.
Things to know …
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 24/143
          Consult TC1854 for database translation compatibilities to see if an intermediate translation is needed (for
          chorus/linux netadmin as well as database)
               There is no automatic translation of Chorus data of Releases below R3.0. You should not restore the
                Chorus data of Releases below R3.0 but perform manually a complete netadmin.
               There is no automatic translation from the Custom Release 3.0C (C1.580.1) to RELEASE 12.3.1 It is
                essential to carry out an intermediate translation with Custom Release 3.2-C2 (C1.762.18 minimum).
               As of Release 8.0.1, the translation creates automatically a fictive shelf in which the virtual UA boards of
                ACT 19 (intended for the assignment of IP sets) will be migrated.
                This fictive shelf is created automatically with the first free shelf number in the translated database.
                In XL configuration, the number of fictive shelves dedicated to IP sets allocation can go up to 3.
               When migrating (use of photoconfig), Actis takes into account the creation of fictive shelves dedicated to
                IP sets allocation.
               all standard SIP sets must be declared with the SIP Extension type. Standard SIP sets are no longer
                supported with the former "SIP Device" mode (formerly called "External set"). Only items other than
                standard sets (Nokia sets in Dual mode, 4135 IP Conference Phones, fax, video, etc.) should remain with
                the former "SIP Device" mode.
                When migrating a system with "SIP Device" / "External set" to R9.0, the system moves these sets into the
                new mode (SIP extension) automatically.
Warning       It is mandatory to declare Nokia sets, used in Dual mode with OXE, and OT4135 IP Conference Phones with
              type "SIP device".
          Procedure to follow:
               Export the SIP entities which are not standard SIP sets (Nokia sets in Dual mode, OT4135 IP
                 Conference Phones, fax, video, etc.) by OmniVista 4760(i) by using “.prg” as export format.
               Remove these entities then migrate to R9.0.
               Import again the items which have been previously exported: standard SIP sets are in "SIP Extension"
                 and the other SIP entities in "SIP Device".
 Note         Fictive shelves dedicated to IP sets allocation created automatically by the system must in no way be
              changed by the management.
               As of RELEASE 11.0, the Direct RTP mode (in network) is automatically enabled and the relative
                parameter removed. The same is done for “H323 Internode Protocol” system parameter.
               When creating a new Media Gateway or an A4645 voicemail after the upgrade to RELEASE 12.1, a GD3
                board will be automatically created and no more a GD one. The already created Media Gateways and
                A4645 are of course not modified and will remain with a GD board. For the A4645 voicemail, absolutely no
                functional difference exists depending a fictive GD or GD3 is used.
          Check if translation performed correctly: operation & error messages are located in a file that can be displayed
          by “swinst”:
          7     Database tools
          OmniPCX Enterprise - Release 12.3.1
          Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
          Copyright © ALE International 2020                                                                    page 25/143
then
5    About last database operation
Translation log file is located under “/usr3/mao/TRANSLATE.dat” and is also included in the infocollect result
file.
5.11 Migrating old versions
       Sometimes there is no automatic translation between 2 releases. An intermediate translation has to be
        done. For that you need to use the document “TC1854en-
        Ed25_OmniPCX_Enterprise_patch_aligment_procedure.xlsm“ in the business portal.
       As the IP addressing plan has changed since Release 3, it is not possible to reuse the Chorus data
        from a previous version in its current state.
       The restoration of Chorus data from a release lower than 3.0 is possible only in the case of a
        intermediate translation in Release  R5.0.1 Ux. A translation is then carried out including the names
        and addresses of the CPU and its twin, addressing by role, the local tunnel, SLIP management and
        "trusted hosts".
       There is no automatic translation of Chorus data of Releases below R3.0. You should not restore the
        Chorus data of Releases below R3.0 but perform manually a complete netadmin.
       The translation of the tunnel creates static LCNs. For a network where all nodes are in R7.1, the static
        LCNs must be deleted.
       It is essential to save the site OPS files (photoconfig). They will be required to be able to carry out a
        migration to R12.0
       If the lanpbx.cfg file was used in Release 3.2, it is essential to save it before passing to RELEASE 12.x
        (usr2/downbin/lanpbx.cfg). It should be restored after the translations in usr3/mao. If forgotten, this
        file should be recreated. For more information, refer to the System documentation (Functional
        documentation/IP-PCX networks/IP Phones section).
5.12 Dect
Each system equipped with DECT needs a unique PARI configured in the system. To obtain the PARI, refer to
articles in TKC : 000007973, 000011120 on Business Portal.
Information about DECT licenses in case of migration.
If you have an OmniPCX 4400 with DECT, you will find the number of DECT sets in the lock 82 (no lock 175
and no lock 200).
If you make a migration to OmniPCX Enterprise, you will be able to see locks 82, 175 and 200. During this
migration, if you update the number of DECT sets, only locks 82 and 175 will change, the lock 200 will keep
the value of the number of DECT sets present in OmniPCX Enterprise configuration.
Example:
OmniPCX 4400 with 50 DECT sets:
       Lock 82 = 50.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 26/143
          Migration to OmniPCX Enterprise:
                  Lock 82 = Lock 175 = 50
                  Lock 200 = 50.
                  If you change the number of DECT sets from 50 to 60:
                  => Lock 82 = Lock 175 = 60
                  => Lock 200 = 50.
                  In that case the maximum declarable of DECT sets is the value of the lock 82 (or 175) but not the
                  sum of locks 82 and 200 or the sum of locks 175 and 200.
          Concerning the new solution ip dect on xBS there is no change on software locks.
Warning    Before upgrade, make sure that the value of the licenses matches the number of DECT users. So, if you
           have more DECT users than the value of the license you have to make an add-on with Actis to increase the
           license.
          Dect migration to xBS
             -   “old” sets are not considered in new ip dect solution (no support, no firmware fix)
             -   Autoreg feature needs a minimum version on each set. Make sure to perform a SUOTA operation
                 before.
             -   SUOTA is not yet automatically set to TRUE. This has to be done manually.
          5.13 New installation
          CCS must be upgraded to version 10.2.92.0
 Note      All OMS in Red Hat should migrate to Suse.
           There is no data backup or translation for doing that: configuration done by “mgconfig” must be managed
           again at the identical.
Warning    Migrating from a CPU7S1/2 to CPU8: if the embedded ethernet was used a new cable has to be
           installed on the cpu that lacks this connection to the external switch.
           This internal interface is not present anymore. See corresponding chapter 18.1.1 new CPUS
          All the elements required for passage to R12.0 are given in paragraphs 7 to 16.
          REMINDER
          It is mandatory to reconfigure the system by Actis even if there is no changing of license or hardware.
          OmniPCX Enterprise - Release 12.3.1
          Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
          Copyright © ALE International 2020                                                                   page 27/143
5.14 Updating the PCSs
Coming from versions lower than R12.0 there is no possibility to use the second partition. Disk must be re-
installed from scratch.
S.O.T. 2.2 can be used for that in environments where telnet/ftp protocols are filtered or NOT.
Method described in TC2338 can be forgotten.
5.15 OmniPCX 4400 migration to R12.3.1
Two possibilities are provided for migration to R12.3.1:
 Migration to R12.3.1, keeping the 4400 type CPU: only CPU7s2 with new memory bank (512Mb) or new
   CP8 are compatible
 Migration to R12.3.1, changing the 4400 type CPU to vm (or Generic Appliance Server) or CS-2/3. This
   operation is done automatically as a translation.
The migration to R12.3.1 offers the same level of functionalities as the R5.0 Ux, except for three restrictions:
 As of Release 5.1, certain applications, hardware or functionalities are no more supported; see paragraph
   5.1.
 The replacing of 4400 CPUs with CD/vm or Generic Appliance Server leads to restrictions on the use of
   certain functionalities.
 In ISO migration, the shelves already created in position 18 and 19 must be moved before the translation.
   If this is not done, they will not start. In fact, when migrating from OmniPCX 4400 to OmniPCX Enterprise
   R11.0 with change of CPU 4400 by an Appliance Server, there is an automatic translation of shelves
   created in these 2 positions. This automatic translation does not exist if the CPU of type 4400 is retained.
Actis is used to migrate locks (resulting from site by photoconfig) of an OmniPCX 4400, proposing migration
packages for functionalities and hardware not supported by R12.3
5.15.1 Use of the hardware key
Hardware key is no more used on CPU7s2 since it is no more proposed by Actis.
Hardware key is not available on CPU8.
5.15.2 Crystal hardware compatibility with an Appliance Server
See also phase-out & compatibility documents
Technical communication TC0778 Migration OmniPCX 4400 to OmniPCX Enterprise describes the steps
necessary for transition to Release 9.1 but is not updated to R12.0
6 INSTALLING THE SOFTWARE
6.1 Using dual partitioning or not
       Coming from ANY version <12.0 the cpu MUST be reformatted: no possible use of
        unactive partition (partitions are resized + multipartition process NOK)
       Coming from R12.0 second partition installation can be used.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 28/143
        6.2 Virtualization
        vm recommendations about installation: consult “TC2431 Virtualization: OXE configuration related to OXE
        releases and ESXi infrastructure versions”.
        6.3 S.O.T.
        S.O.T. general release is 2.2
        - includes installation of OMS, OST, GAS … etc
        - installation of PCS in secured environment! new in 2.2 (with cpu reformatting)
        Reminder:
            -   Flex server installation does not need any 3rd party tool (vmware or kvm solution)
            -   PC Installer is no more supported. Installing old versions will be not available as well as boards
                firmware reload.
            -   PC Installer is no more present from OXE R12.3. For those who still want to use it, install & use the
                latest version 5.5 No support will be provided.
        6.4 Installation of PCS (OXE secured or not by ssh)
        Update PCS systems then update Main & Stdb CPUs
        The issue when using “pcscopy” where PCS become unreachable after reset is fixed on this version.
        Coming from a release up to L2 the PCS needs to be reformatted (new Linux M1/R12.0 constraint). Upgrade
        of a PCS without being physically at the PCS location is now done with S.O.T. version 2.2 minimum.
        6.5 Using the Remote Download
        Remote download is NOT operational when coming from ANY version to M1.403.x
        But it is operational FROM M1.403.x to M1.403.x & above
Tip !    Remote download allows to perform programmed & scheduled operations (load, installation).
         Switch back to unactive partition is possible through a specific question & guaranties a more secured
         upgrade. If answered yes, ANY kind of reboot will switch back to the other partition. This behavior can b
         Cancelled if system seems stable.
         Remote download operations can be programmed, sequenced & executed at a specific time.
         Switch to the new version (from active to unactive partition) can be programmed at a specific time: in that
         case the copies of database & Linux data will be performed automatically from active to unactive partition.
         Consult system documentation for operational details.
        Notice that this operation even if still working is replaced using S.O.T.
        OmniPCX Enterprise - Release 12.3.1
        Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
        Copyright © ALE International 2020                                                                   page 29/143
6.6 Secured systems
6.6.1 Security activated by default during an installation
At the first standard installation, a list of security levels is displayed before any other configuration is possible.
This list proposed in a menu on the first login on Call Server, makes it possible to sensitize the Partner
Business on the policy of security which he will have chosen for the system.
The absence of security on the system, which remains always possible, will be under the whole responsibility
of the customer.
Description
On the first login after the standard installation of a Call Server, the question Do you want to activate
server security high level (Y/N)? is displayed.
An answer (Y or N) is mandatory to quit the menu.
Answer N
The following menu appears:
        Select server security level:
        R) Configuration to be restored
        0) Level_0 = no security feature activated
        1) Level_1 = password/aging
        2) Level_2 = password/aging + trusted hosts/TCP wrapper
        3) Level_3 = password/aging + trusted hosts/TCP wrapper + SSH
Choice R is used to restore Linux data of the system (and thus to retain its levels of security)
Choice 0 is used to initialize the system with no default level of security NOT RECOMMENDED
Choices 1, 2 & 3 are used to set the various levels of security by mixing between them if necessary:
    Choice 1: Modification of passwords of root, swinst, mtcl and adfexc accounts and enabling of the
        aging password function
    Choice 2: Choice 1 + enabling of the trusted hosts and TCP wrapper
    Choice 3: Choice 2 + enabling of the SSH service
Answer Y
The level of security 3 is automatically set. It is highly recommended to use this level.
6.6.2 Installation of a secured system for VoIP encryption ("IP Touch Security" service –
    Thales solution)
Thales encryption: for reasons of export control of encryption technology, a patch called patch of security is
provided in addition to the generic version.
This patch of security contains only the secured binaries for IP Touch sets and the binaries of "IP Touch
Security Modules".
There is no need of this kind of patch for Full Software Native Encryption feature.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14       TC2632en-ed.06
Copyright © ALE International 2020                                                                       page 30/143
Installation process
The installation of security on a system in M4.302.5.H must be carried in two steps:
1. Installation of system with generic version i.e.:
   Installation generic version M4.302, installation of static patch M4.302.5 and then installation of dynamic
   patch M4.302.5.H
2. Installation of the latest patch of security in addition of the previous installation i.e.:
   Installation of the security patch SM4.302.5.H called also containing the latest secured binaries.
6.7 Reading the hardware key, CPU-id, CCS-ID
On a label on the CPU
For all types of CPU (CS-2, AS, CPU7s2), a label is visible indicating the CPU-Id number.
For virtualized systems, the equivalent of the cpuid is the dongle (reference written on it).
Through a command to read the CPU-Id or CCS-id
For all types of CPU (including virtualized but not valid: no cpu-id in that env.), telephone started or not,
execute the command “spadmin”, option 5: “Read the system CPUID”
CCS-id used in Cloud Connect belongs to the swk file
“spadmin” choice “Display active file”. CCS-id is displayed as CPU0
Ex: “Cpu Id 0 = CCSID:3834-5945-xxxx-xxxx-xxxx”
6.8 Restoring Chorus/Linux data, twincpu
It is possible that the Chorus data of certain old releases cannot be reused automatically: manage “netadmin”
by hand in that case.
All modifications in netadmin must be carried on twin cpu (netadmin menu: copy to or from twincpu)
7 INSTALLING & CHECKING Actis files
The procedure for installing OPS files puts together the following steps: RUNMAO, translation of the database
and installation of the OPS files.
7.1 Procedure
Copy the OPS files using "ftp" in the directory /usr4/BACKUP/OPS.
Use the menu swinst/OPS configuration.
The progress of the different translations is not visible on the screen.
At the end of the procedure, the operator is asked whether they wish to start the telephone. Answer NO.
Reboot the Call server.
7.2 Checks on physical CPUs
Check the coherence of the lock file compared to the database using the command spadmin:
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 31/143
       Select 1 Display current counters. The "Panic flag" should be at zero.
       Select 2 Display active file if System CPU-Id not found is displayed. This means that the CPU_ID of the
        CPU used does not correspond to the CPU_ID defined in the software.mao license file. This situation is
        normal if you have chosen to prepare the migration on a laboratory CPU.
       Select 3 Check active file coherency. The test should reply File OK.
7.3 Checks on virtualization
Important documents:
TBE043 - OT Suite for MLE - Virtualization Design Guide
TC2431 Virtualization: OXE configuration related to OXE releases and ESXi infrastructure versions
In case the cpu is installed in an esx or KVM environment the check of the cpu-id gives back “Your System
CPU-Id: -no-hard-key-“
The “swk” file contains a “K….” value instead that is the name of the file installed on the flex server. That file
on the flex server will contain the identification of the dongle. So, it is not possible to do this kind of check.
In spadmin, menu “Display current counters” verify that the first info is:
Meaning that everything is ok:
       Flex server is reached & dongle is controlled
       “Panic RTR Check” relates to the Cloud Connect feature appeared in R12.0)
Checks when a remote dongle is configured:
It is not possible to see if the system is equipped with a remote dongle. Checks must be done on the flex
server itself. Flex has a very specific way of handling dongle disconnections & extractions: look at the pre-
sales documentation for more details.
7.4 Checks on Cloud Connected system
See above in “spadmin” tool: Panic RTR Check should be 0 as well as “PANIC Flag”
8 CLIENT INFORMATION
The purpose of this section is to specify the changes in ergonomics or operation that will be visible or available
to users after changing version.
New ergonomics and operations
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14     TC2632en-ed.06
Copyright © ALE International 2020                                                                     page 32/143
8.1 Reminder of changes appeared in Release R12.3.1
WMI LED synchronization (see also chap.15.2.1 – call handling features):
The message icon is now in synchronization with call log. For a NOE device if the call log access rights are
false then the internal/external unanswered calls list will be available. The message icon is now in
synchronization with internal/external unanswered calls.
New Codec OPUS (superwideband) if validated produces a much clearer voice communication (restrictions :
only P2P local comm.) Need of a new wired handset.
8.2 Reminder of changes appeared in Release R12.3
OXE Integrated Call Log also for CCD agents
4059EE attendant: possibility to disable OXE phonebook ldap overflow when the 4059EE performs a call by
name query (management to do)
Users: greeting guide when calling a hunt group. Local feature (management to do)
Users: “no multi-line call in PCX” (a huntgroup should take care of "busy camp-on" setting of user in multiline
configuration: management to do)
8.3 Reminder of changes appeared in Release R12.2
Applications support on 8088 Android. Today only ALE specific applications are compatible due to specific
developments related to the screen size.
Possibility to use an 8058S phone as a 8068S: virtual keys removing. Phone will still not benefit of the Blue
Tooth due to hardware design.
Dect sets can be pro-ACD agents now.
Disable loudspeaker on IP phones.
DECT set should be seen available during "busy" states (MD1 patch)
DECT: long press on green call button (redial feature): behavior can be changed
8.4 Reminder of changes appeared in Release R12.1
New sets available: 8008 & 8088 Android/noe (no app support)
OXE native call log for calls on busy sets
Support of alarm button on ASCOM MIPT dect sets
8.5 Reminder of changes appeared in Release R12.0
New 4059EE (directory research)
Increase ABCA queue length on 4059 EE
New range of sets (8058S/ 8078S)
Call duration enhancement
Deleting alarms on DECT
Multi-device
New Rainbow application
Security enhancement of A4645
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 33/143
8.6 Reminder of changes appeared in Release R11.2.x
Shortcut to missed calls on DECT
New 4059EE look & feel
Acces to the outgoing calls list via the green touch
Phone user password management
Extended Rapid Call Shift (no more tandem needed, network ABC)
8.7 Reminder of changes appeared in Release R11.1
Call log on all IP/TDM & Dect sets
Rapid call shift & NFC feature on Android cell phones
8.8 Reminder of changes appeared in Release R11.0.1
Attendant on 8082 sets (same ergonomics as 4068 sets)
Introduce new dect set 8242 (Note the 8242 MD1 is expected end December 2015)
Introduce new TDM & IP Phones: NOE3G (Premium sets)
8.9 Reminder of changes appeared in Release R11.0
   Don't display OXE call log counters when ICS/OT call log is deployed for the IP Touch 8 series EE
   Increase the number of personal directory entries on Dect Hansets
   A4645 security enhancements:
     Access to the voice mail can be blocked after a number of specified failed attempts
     Callback sender via public network
     Notification via public network
     Users connecting from outside the system cannot access their voice mail with the default password
     users connecting from outside the system cannot access the voice mail system
   Desk Sharing Users will be prompted to change their Secret code at first login if they have the Default one
8.10 Reminder of changes appeared in Release 10.1.1
A new ergonomics appears for the IP Touch 8 series EE.
 Visual SIP Voice Mail Access from IP Touch Mail key
8.11 Reminder of changes appeared in Release 10.1
   Transparent reboot on IP Touch 8 series sets Extended Edition
   Call restriction management for 4068 attendant
   Desk Sharing for IP Touch 8 series sets Extended Edition
8.12 Reminder of changes appeared in Release 10.0
A new ergonomics appears for the 4059 application.
 Localization: Japanese on 4059 (Windows 7)
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 34/143
   Localization: Hebrew for 4029/4039 TDM sets from J1.410.38
8.13 Reminder of changes appeared in Release 9.1
A new ergonomics appears for some features of 40x8 sets and MIPT.
 Localization: Hebrew (only for 4028/4038/4068 sets).
 Localization: Arabic (only for 4028/4038/4068 sets), from patch I1.605.14.e.
 PERSO page displaying after a time-out.
 MIPT alarm display.
 Translation improvement (Korean language) in IP Touch, from I1.605.24
 Search in internal phone book with several results for internal numbers and abbreviated numbers, from
    I1.605.31
8.14 Reminder of changes appeared in Release 9.0
   External called number display after call answer (managed by a system boolean).
   Localization: Valenciano language.
   Local time display on sets located in a time zone different of CS as well as in mini-messages, the list of
    non-answered calls, Wake-up/Appointment requests.
   It concerns voice messages time/date stamp only for OT8440 (not 4635 and 4645).
8.15 Reminder of changes appeared in Release 8.0 and 8.0.1
   Dial by name with IME (Input Method Editor) on 40x8 and 40x9 sets.
   Localization of softkeys on 40x8 and 40x9 sets.
   Display of Perso page on hang-up on IP Touch sets in Hotel configuration.
8.16 Reminder of changes appeared in Release 7.1
   Japanese on IP Touch 40x8 and 40x9 sets.
   Display of the names in UTF-8 format on Alcatel 4059 application.
   Applicative softkey integration on IP Touch 40x8 sets.
8.17 Reminder of changes appeared in Release 7.0
   VoWLAN Release 2.0: New ergonomics of VoWLAN sets using the NOE set protocol.
   Local name UTF-8 (Unicode Transformation Format 8) for users (25 characters).
   Support of traditional Chinese (Hong Kong, Taiwan), Korean, Japanese languages.
   Caller name extracted from personal directory.
   Back to the top of Perso page by default.
8.18 Reminder of changes appeared in Release 6.1.1
From Release 6.1.1, new icons of supervisions are available regarding the IP Touch sets.
8.19 Reminder of changes appeared with R4.2
   Check management of the ringing melody on digital sets.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 35/143
    If you migrate from a release below 4.2, you should change the ringing melodies of internal/external calls;
    see the technical communication TC0297 Change of external/internal ringing melodies in Release 4.2.
8.20 Reminder of changes appeared with R4.1
   Twin set (Tandem)
     Management of "Partial Busy of the set".
     Enhancement of supervision function.
8.21 Reminder of changes appeared with R3.0
   Digital sets
     Storage of no replied local/internal calls (consulting using the message key).
     Storage of no replied ISDN calls on all sets with display: 4011, 4012, 4023, 4034, 4010, 4020, 4035.
   Attendants
     Call between attendants.
     New call statistic distribution.
   4040 set
     This set is no more supported from Release 3.
   UA 3G sets
     Following a translation, the existing 3G sets remain in 2G mode emulation. Their change (where
       appropriate) to 3G mode is done by management (Users). The UA 3G sets created from Release 3.2
       are in 3G mode by default.
9 SYSTEM MANAGEMENT
9.1 General
Declare the automatic start-up of the telephone in swinst
Manage date/time in swinst (use “ntp” feature if possible)
In case of virtualization manage the ESX in order to be sure that all VM will restart automatically if the server
reboots (vSphere client management)
Make sure that a periodic backup of the database is programmed (“swinst”)
X25 networks:
IP routing is handled by the "gated" or “routed” processes and can only operate if the same process is
validated for all the nodes. Pay special attention to the nodes in previous versions using the "routed" process.
These two processes are not compliant between them. In a network in Release 3.2, manage the same routing
protocol (RIP2 or RSL) on all the machines
9.2 Special case of IO2N boards (CPU7s2/ CPU8)
CAUTION
 IO2 boards are phase-out and cannot work from R12.0
 CPU6 & CPU7s1 are no more supported
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 36/143
   On a duplicated installation, if an IO2N is declared in the database, it is essential that it be present when
    starting up, otherwise the CPU will not restart. In fact, telephone signaling is now processed by the IO2N
    when present (otherwise it is processed by the IO1 module of the CPU as in previous versions). It is
    however possible to start without IO2N using the command “RUNTEL -DNOIO2” as mtcl user. This
    should only be a temporary mode.
   If this first start-up is carried out on a model, put in place at least one UA or Z coupler in place of a UA or
    Z coupler of the site as this will allow the correct operation of the IO1 or the IO2N to be checked.
9.3 Integrated WebBasedManagement
WBM was tested on:
   Windows 10 Enterprise 32 bits, Windows 10 Professional 64-bit, Windows 7 Professional 32-bit and
      64-bit versions
   Windows 8.1 Pro 32-bit and 64-bit versions
   Windows XP SP3 and Windows Vista Business Edition
   Windows 2012 R2 (64-bit)
   Compatibility with Win2016 Server (64-bit)
   compatible with VMware ESXi 5.5
Browsers supported are the following (make sure to always have the latest version):
    Chrome
    FireFox
    Edge (on Windows 8/8.1/10 64bits)
10 COMPULSORY MINIMUM ADDITIONAL DATABASE MANAGEMENT
10.1 Reminders
Management of the number of transits.
There is a parameter used to define a number of transits for a same call across the network. This is a
protection used to avoid call looping.
Procedure:
 Access path : System
 Attribute     : Number of transit PABX
 Manage the parameter with a value identical to the number of network nodes.
    CAUTION: If this parameter is zero, call transit will not work.
Optimizing the routing in network
To optimize a network, you must create a PABX address in DPNSS (Local Features) prefix. This prefix must
correspond to a directory number that has not been created in the installation.
For each machine, create a PABX address in DPNSS prefix and as many network prefixes corresponding to
the DPNSS addresses of the other machines as there are remote machines.
Example: System with four nodes.
Each node has its PABX address prefix and each will have three network prefixes corresponding to the
different PABX addresses of the three other machines.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14     TC2632en-ed.06
Copyright © ALE International 2020                                                                     page 37/143
          10.2 Reminder for ABC networked sites migrating from Release < 7.x
          As of Release 7.0, a new feature is used to display the names with UTF-8 format (long names and for non
          Latin languages: Chinese, Korean, Japanese).
          In ABC-F2 network functioning, from RELEASE 11.0 the name in UTF-8 format is used in the network
          according to the setting of the Enable UTF8 in ABCF network system parameter (default value True).
          This information is accepted only from the following versions:
           R6.2          : F3.301.16.e (patch for compatibility UTF-8)
           R6.1.1        : F2.502.12.d (patch for compatibility UTF-8)
           R6.0.1        : F1.603.1.aa (patch for compatibility UTF-8)
          If RELEASE 12.0 is functioning in ABC-F2 network with nodes the versions of which are lower than those
          mentioned previously (case of temporary phase of migration with R5.0 Ux, R5.x, R6.x), you must set the
          Enable UTF8 in ABCF network system parameter to False on nodes where RELEASE is => 11.0 otherwise
          the calls through the network don't work.
Warning    In a network, if a node is declared XL ("Large Capacity"), each node of the network must be in Release 8.x.
           minimum
          The system parameter Direct RTP must be enabled in all nodes of the sub-network as soon as one node is
          migrated in RELEASE 11.0
          10.3 Important management if IO2N is present
          To solve traffic issues on CPU7s2 (issues related to CPUs crash or peripheral racks rebooting, issue that could
          also be seen in CPU8) the signaling to IO2 must be changed. Notice that this management can be done for
          any configuration even with very low traffic with no impact on the system.
          On ACT0:
          2 ways of changing the signaling:
              signaling channel for ACT0 only must be as follows:
               Signaling mode = IO2 instead of Nx64
               Signaling Channel N64 Size = 8 instead of 4
              Access path
                       Shelf 0/Signaling mode: IO2
                       Shelf 0/Signaling Channel N64 Size: 8
          Or
              signaling channel for ACT0 only must be as follows:
               Signaling mode = Ethernet instead of Nx64
                  Access path: Shelf 0/Signaling mode: Ethernet
          This management must be followed by a reboot of the installation.
          For the remote shelves:
          OmniPCX Enterprise - Release 12.3.1
          Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
          Copyright © ALE International 2020                                                                   page 38/143
          apply the same management: Signaling mode = IO2 with only 4 channels. Don’t exceed the 60 channels of
          the board. Include the 8 channels used for duplication in crystal 0.
 Note      The IO2N board must be at the minimal edition 07. Refer to the technical communication TC0567 Reboot of
           the CPU board after an inopportune shutdown of IO2N board.
          10.4 Important management with sets (noe3Gs, 8018)
          By default, an OXE with a default database is configured to use G723
          But new generation of IP Phones like 8018, 8058s… do not support the G723.
          In consequence, the communication gets no audio.
          Changing the system compression defaults immediately fixed the problem.
          10.5 Synchronization
Warning    The ACT 99 does not allow synchronization to be passed up to the CPU.
          In the event of common hardware, one cannot use a T0 board behind a MEX to synchronize the shelf.
Warning    For migration of a Crystal CPU to an Appliance Server, it is compulsory to change synchronization
           management to IP domain type. The synchro priority value must be between 200 and 254; see technical
           communication TC0779 Synchronization of the system after migration to OmniPCX Enterprise with
           Appliance Server.
          10.6 Some system parameters to check
          Use the command “compvisu” to display some of those parameters.
          10.6.1 Direct RTP
 Note      In this document, "Direct RTP" corresponds to "Direct RTP in network".
          In all nodes of the sub-network the Direct RTP parameter must be set to Yes.
          From OmniPCX Enterprise R11.0, this parameter is removed (validated by default).
          10.6.2 Frame VoIP (Enhanced quality voice)
          The Frame VoIP parameter (Enhanced quality voice in previous versions) must be identical on each node
          of a network.
          It is better to use the Framing 20 ms for G711 or G729.
          OmniPCX Enterprise - Release 12.3.1
          Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
          Copyright © ALE International 2020                                                                   page 39/143
G723 can only do 30 ms.
10.6.3 Direct RTP for H323 terminals
This parameter must be set to No if only one H323 terminal of the installation does not support the direct RTP
10.6.4 Inter-node protocol H323
The “H323 Inter-node protocol” parameter must be set to Yes in all nodes of the sub-network. In an OmniPCX
Enterprise R11.0 system, this parameter is removed (validated by default).
10.6.5 tftp (oxe)
OXE tftp can be tuned in some circumstances (eg: big files to transfer)
mgr -> IP -> IP Parameters -> Review/Modify: IP Parameters -> TFTP Max Block Size
mgr -> IP -> IP Parameters -> Review/Modify: IP Parameters -> TFTP Retransmission Timer
11 STARTING UP THE CPU IN ITS ENVIRONMENT ON SITE
CAUTION IN DUPLICATION STATE:
Do not proceed by switchover for 2 different releases: a complete stop of the telephony is required. It is not
recommended also to proceed by “bascul” when installing a static patch though there is no clear rule
established. During that time (patch n & patch n+1 on main & stand-by), the command “twin” may return the
status “KO” for the “memloader” check.
Complete system start-up: this will allow to download automatically the new firmware of the couplers and to
avoid having memory issues (as mentioned above).
11.1 Download of couplers and sets
The first start-up of the CPU in its site environment requires particular attention since the couplers will be
downloaded with a new firmware.
To download the INT1B couplers, they must be removed from the secondary ACTs and put in place of the
INT1A couplers of the main ACT.
Use the “downstat” command to monitor the evolution of the coupler downloading. The CPU ensures 25
downloads simultaneously. The state of a coupler during downloading is RUNNING 1.
Use the “downstat d” command to obtain boards that have to be downloaded
Use the “downstat v cr cpl” command to display 'binaries' version for a coupler
It is possible to program an automatic reset of the couplers with the option 'r'.
Reset manually the UA32 or eUA32 boards of shelf 0 if they do not start (do not concern OmniPCX Enterprise
with common hardware or controlled by an Appliance Server).
Use the “downstat i” command to monitor the evolution of IP Phones (e-Reflexes, IP Touch series 8)
downloading.
Use the “downstat t” command to monitor the evolution of IP Touch TDM (series 9) downloading.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 40/143
Note       8082 sets in NOE mode & also new noe3G/Premium sets can do upgrades in background mode: once the
           download is finished the set will reboot. If a communication is already established, the process will wait for
           the communication to end.
           IPV6 feature: sets in pure ipv6 network will get their binaries from the OST64 virtual machine: the OST64
           must be rebooted in order to perform the correct download mechanism.
       11.2 8088 Android upgrade
       Upgrade mechanism through the Cloud is done by management.
       Notice that Android 8088 sets cannot be downgraded even if re-installed on a lower OXE version.
       11.3 SIP sets upgrade
       Operation must be carried by 8770 Device Manager. Check on the Business Portal for latest versions of SIP
       sets.
       11.4 Moving from CPU7s1/2 to a CPU8
       Warning about the embedded ethernet interface that does not exist anymore.
       12 CHECKING CORRECT OPERATION
            Check synchronization.
             Ensure that the real synchronization plan corresponds to the managed synchronization plan. Use the
             command “infocs” or “clockstat”.
            Check the distribution of calls to attendants.
            Check the ARS & VPN: use “lookars” & “lookvpn” embedded OXE tools.
            Check that all sets & couplers are correctly in service & downloaded & sets are in service: use the different
             commands “downstat”, “config”, “listerm” with the correct arguments (help available)
                     o For noe sets use “downstat i” & “tftp_check -c” tools
            Check the coherence of the files (Suspicion of errors during file transfer: ftp must be set to “binary”
             mode).
             login                      Swinst
                 option 8               Software Identity Display
                 option 6               Application Software Validity Checking
             Press 0 for the active version, 1 for the unactive one or q to quit
             Please wait .....
       OmniPCX Enterprise - Release 12.3.1
       Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14     TC2632en-ed.06
       Copyright © ALE International 2020                                                                     page 41/143
    Checking mode : 1=size & sum 2=size only (default is 1) 1
    Checking size and sum of all files , please wait ...
    file modified (authorized) : /DHS3data/manager/mtcl.adm
    The application software is correct
    Press return
   Check duplication status: use command “twin”: each line should be in “OK” state. Use also “twincompat” :
   Quick check of machine coherency
   Check of version: use “siteid” to know which version/patch is loaded & also to check if it is an encrypted
    patch (SSM boxes)
   Check encryption (Native or SSM boxes) : use “cryptview” tool
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 42/143
   Check start-up of the IBSs behind INTOF.
   Check start-up of the INTIP used in particular for the remote ACT. Faced with a board initialization
    problem, check that the value MTU in the IP Parameters is correctly managed at 256.
   The Meet me type relating to the DSP in Add On must be changed via the Modular conference menu.
    Access path: mgr/System/Shelves/Gpa Dsp program/Modular conference
   Dect xBS
    Check xBS state with “dectview xbs” & synchronization tree with “xbssynchro”
13 CHECKS IN A VIRTUALIZED VMWARE INFRASTRUCTURE
        Consult documents “OpenTouch Suite for Medium and Large Enterprises - Virtualized offers” &
         “TC2431 Virtualization: OXE configuration related to OXE releases and ESXi infrastructure versions” for
         more about vm rules configurations in esxi vmware environment.
   Make sure the correct management is done in order to autostart all the vm after a server reboot or power
    fail
   Flexserver: be sure that connection is ok between OXE & that server(s). Log files in the flex server (check
    in /opt/Alcatel-Lucent/logs/flexlm/ files: system documentation “Call Server in Virtual Machine” section).
    Look also for OXE incidents from 640 to 644 (FLEX issues).
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 43/143
   Remote dongle: check the connection to the Raspberry (make a ping from the Flex to the R PI2)
   Remote dongle compatibility: Raspberry Pi 2 Model B or Raspberry Pi 3 Model B.
14 COMPATIBILITIES/ PRODUCT LIMITS/ FEATURE LIST
14.1 Documents
Check documents listed below and in chapter 2 (compatibilities, limits …)
OXE product:
            - OmniPCX Enterprise Release 12.3.1 Presentation
            - OXE (from R10.0 to R12.3) Global Feature List
8770 product:
            - OmniVista 8770 R4.1 Release presentation
OT product:
            - OpenTouch 2.5 Overview
            - OpenTouch architecture and network design principles
System documentation:
            - OmniPCX Enterprise R12.3.1 Documentation note
            - OXE R12.3.1 Documentation package (All languages)
Other:
            - Cross Compatibility - MLE - April 2019
            - Release Policy Information - MLV - April 2019
            - MLV_ReleasePolicy_PhaseOutProduct_April_2019_Ed43a_ENT_MLE_034198.xlsx
All documents located at the Business Portal (do a search on titles listed previously):
https://businessportal2.alcatel-lucent.com/
14.2 Status of the Version (database, Product Reports)
Patch M450114 - MAO DB software version: M45014
        Patch                         Patches Aligned                       DB version Compatible till
         j2.5                            j2.501.23                                   j2.501.21
          j2                             j2.603.38                                   j2.603.38
          k1                             k1.400.37                                   k1.400.35
         k1.5                            k1.520.47                                   k1.520.43
          l1                             l1.301.42                                   l1.301.41
          l2                             l2.300.43                                   l2.300.43
         m1                              m1.403.27                                   m1.403.26
         m2                              m2.300.29                                   m2.300.25
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 44/143
         m3                             m3.402.32                                    m3.402.26
14.3 Interoperability tests status
14.3.1 OXE compatibilities in ABC network
ABC Interworking tested with R11.2.2, R12.0, R12.1 & R12.2/R12.3.1
The table below shows the compatibility in ABC network: extract from cross compatibility document. No patch
number is named: always take the latest one. Extract from the “cross compatibility” document.
Grey cells do not mean that is it not compatible.
Table must be read like this: column version compatible with the line version.
14.3.2 Open Touch
OXE R12.3.1 is compatible with OT R2.4 & 2.5
Check document “MLE_CrossCompatibility_April_2019_Ed35_ENT_MLE_034190”
OTxx interworking:
            OTMS version 15.0.010.007
            OTMC version 15.0.010.007
            OFC R7.6 version R7.6.0.94
            OTCT PC version 2.4.17.000
14.3.3 OXO interop.
OXO interoperability was tested between OXE release M4 and OXO version ONE030
14.3.4 IP sets compatibility
Refer to “MLE_Cross_compatibility” document for ip sets compatibility. Inside that document, check for more
details in chapter 7: “Endpoint compatibility”.
14.3.5 8770
OXE R12.3 was tested with 8770 4.1.10.00 patches A-F – also compatible with R12.3.1
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 45/143
14.3.6 Sub-device on older sets
This part has been removed from this document. If necessary check older document “11.1 release note”.
14.3.7 Common hardware & Crystal hardware mixed
This part has been removed from this document. If necessary check older document “12.0 release note”.
14.4 Appliance Servers & GAS: compatibilities
The following table shows which servers can be installed in OXE native mode & GAS mode.
Notice that those servers are submitted to phase out scheme: in this case only the concerned servers will be
able to be reinstalled in GAS mode. Otherwise a new server will have to be ordered.
For the 4 servers listed below it is possible to make them work with cpuid, dongle/flex or CCS-ID (Cloud
operation)
Future servers will ONLY work in GAS mode in dongle/flex or CCS-ID.
Refer also to Cross Compatibility document for more details on Appliance Servers characteristics
Appliance Server model                Installed in OXE native                Installed in OXE GAS
HP G8 (v1/v2)                         R10.1                                  R12.2
                                      R11.x                                  >R12.2: YES until phase-out
                                      R12.x
                                      >R12.x: NO
HP DL20 G9                            R12.x                                  R12.x
                                      >R12.x: NO                             >R12.x: YES until phase-out
Lenovo x3250 M5                       R11.x                                  R12.2
                                      R12.x                                  >R12.x: YES until phase-out
                                      >R12.x: NO
Lenovo x3250 M6                       R12.x                                  R12.2
                                      >R12.x: NO                             >R12.x: YES until phase-out
14.5 UPS on A.S. & GAS
In the case of a local 110 Volt power supply, the following MGE (now Eaton) UPSs are compatible with the
Appliance Server concerning power cuts and battery management:
 Pulsar Evolution (Serial)
 Pulsar ESV+
 Pulsar EX
 Pulsar ES+
 Pulsar EXtreme C
 Pulsar / Comet EXtreme
 Comet / Galaxy (Serial)
The UPSs referenced in the catalog are not compatible for countries using 110/127V.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 46/143
GAS does not support feature of shutdown through USB connection from those UPS models. This
is planned in a further release.
14.6 SIP sets, Dect sets, other sets … Latest firmware tested.
The set mentioned below do not have their firmware embedded & uploaded by the OXE.
Some of those sets are dual mode (containing the noe mode)
The versions listed below are the latest versions compatible with R12.3
Even lower firmware versions may work but it is recommended to upgrade in case of malfunctioning before
raising a Service Request.
                     Firmware version        Business case       Phased out       Install/update by …
SIP SETS
8001 / 8001G         R200_4.5.0.3            Business            N                8770
8002 / 8012          R110_03.059.0           Business            Only 8002        8770
8008CE               R510_1.51.03            Business            N                8770
8018                 R510_1.51.03            Hotel/ hospital     N                8770
8082                 R300_1.015.18           Hotel/ hospital     N                8770
8088                 4.008.6.668             Business, Hotel/    N                8770
                                             hospital &
                                             huddle room
                                             (sip device)
80x8s CE             R510 1.51.03            Business            N                8770
8135s IP             v2.0.17                 huddle room                          8770+Internal web admin
conference phone
Vtech S2210          SIP_58.3.80.10          Hotel/   hospital   N                External   Vtech   tool
Vtech S2211          SIP_58.3.80.10          Hotel/   hospital   N                External   Vtech   tool
Vtech S2411          SIP_58.3.80.10          Hotel/   hospital   N                External   Vtech   tool
Vtech S2411 SD       SIP_58.3.80.10          Hotel/   hospital   N                External   Vtech   tool
ATTENDANTS
4059EE               2.1.1.9                 Attendant           N                Dedicated installer utility on
                                                                                  PC
4059 IP              5.5_4                   Attendant           N                Dedicated installer utility on
                                             Windows 8/8.1                        PC
                                             (64 bit),
                                             Windows 7 (64
                                             bit & 32 bit) and
                                             Windows XP (32
                                             bit)
NON SIP SETS
8115 / 8125          9.0.12                  Conference          N                Boot on a USB stick on the
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14        TC2632en-ed.06
Copyright © ALE International 2020                                                                        page 47/143
                                             module                               terminal
DECT
Dect 500             v10.88                                      N (note)         FLASHLOADER     application
Dect 500 EX          v20.05                                      N (note)         FLASHLOADER     application
8212                 v0007 b0003                                 N                FLASHLOADER     application
8232                 R130_V43.83.b0004                           N                FLASHLOADER     application+
                                                                                  SUOTA
8242                 R120_V63.82.b0003                           N                FLASHLOADER     application+
                                                                                  SUOTA
8262                 R200_V56.81.b0006                           N                FLASHLOADER     application+
                                                                                  SUOTA
8262 EX              R200_V56.81.b0006                           N                FLASHLOADER     application+
                                                                                  SUOTA
IPDECT R170          DAP firmware for        Dect on IP          N (note)
                     4080 Access Point
                     : 4910b630.dwl
                     DAP firmware for
                     8340 Access Point
                     : 4920b630.dwl
                     DAP loader package
                     : 4992030a.dwl
                     DAP controller
                     versions
                     : 6.21.0299
“Note”: sets NOT compatible with dect ip xBS solution
Minimum DECT sets versions for Auto-registration feature:
     8212 – v0012b0002
     8232 – v4383b0004
     8242 – v6382b0003
     8262 – v5681b0006
     8262Ex – v7682b0006
14.7 Genesys Compact Edition
The “Genesys Compact Edition (GCE)” product is phase out. Previous mentioned patch is not tested anymore
& may not operate correctly.
Check with your local presales for a replacement solution.
15 NEW FEATURES AND NEW HARDWARE IN RELEASE 12.3 & 12.3.1
You can also refer to the System documentation.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 48/143
15.1 New hardware
15.1.1 Set 8008G
8008G is an IP Touch Set similar to 8018 Set, intended to replace 4018 NOE 2G IP phone and 8001 entry level
SIP device. Set 8008G has added the Gigabit Ethernet capability of the Set 8008 in OXE.
15.1.2 Set 8008G CE
CE like Cloud Edition. This set is SIP & cannot be switched back to noe.
15.2 New features: description/explanation & management
15.2.1 Call Handling features
15.2.1.1 Attendant 4059ee version 2.1.1
4059EE R2.1.1 version 2.1.1.12
Changelogs for 4059EE:
Note: consult previous document edition for complete 2.0 changelog (also present at the Business Portal)
2.1.1.12
General:
        BUGFIX:          Result columns not picked up by roaming settings
2.1.1.11
General:
        BUGFIX:          App crash on multiple contact card items
        BUGFIX:          Roaming pam settings not loaded correctly
2.1.1.10
General:
        BUGFIX:          Contact card; presence applied on empty items
        BUGFIX:          Multiple items not shown in contact card
        BUGFIX:          Pager incorrectly displayed in phone column
2.1.1.9
General:
        BUGFIX:          Contact card; sometimes not possible to speed dial numbers
Feature: OXE
        BUGFIX:          SR 00449111, Wrong status of 4059EE call log
2.1.1.8
General
          BUGFIX:        Contact card: Operator information field lacked scrollbars
          UPDATE:        Improved presence support in search result grid
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 49/143
2.1.1.7
Feature: OXE
        BUGFIX:       SR 00449111, Wrong status of 4059EE call log
2.1.1.6
OpenTouch:
        BUGFIX: 00428039 - No update of status BLF
2.1.1.5
General
          BUGFIX: 413737 -Blf context menus not translated
2.1.1.4
General
        NEW: Contact items containing url's invokes default browser on click.
Feature: OXE
        BUGFIX: 00408889 - Number lost in call history
2.1.1.3
General
          BUGFIX: Message template not updated on doubleclick action
          UPDATE:       Language resources updated 2019-08-28
2.1.1.2
General
          UPDATE:        Language resources updated 2019-06-18
2.1.1.1
General
          BUGFIX: 00391508 - BLF item import failure
          BUGFIX: 00391510 - BLF background changes
          BUGFIX: 00386995 - The application shows the name twice in user details
2.1.1.0
General
          NEW:   Weekly and monthly calendar views
          NEW:   Colorized blf items
          NEW:   Touch improvements
General
        BUGFIX:          00378230 & 00378234 - Issue when search in OXE phone book
Feature: OXE
        BUGFIX:          00380765 - App crash on missing abcacom registry access keys
        BUGFIX:          No room for 'Use https' settings label
2.1.0.7
Feature: OXE
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 50/143
      BUGFIX: 00386995 - The application shows the name twice in user details
UD LDAP:
      BUGFIX:       TLS issue
2.1.0.6
General
        BUGFIX:          00378230 & 00378234 - Issue when search in OXE phone book
Feature: OXE
        BUGFIX:          00380765 - App crash on missing abcacom registry access keys
2.1.0.5
General
        BUGFIX: Result columns persist regardless of returned searchdata
        BUGFIX: Last result column allowed to be unchecked
        BUGFIX: Retrieved mappable columns added dynamically to user settings
        BUGFIX: Contact card toolbar sometimes incorrectly resized
        BUGFIX:        00345909, Abc-a disconnected on frozen Ldap query
UD General:
        UPDATE:        EE preserve all search requests except 'Image' for repeat operations
Feature: OXE
        UPDATE:        Abcacom.exe updated to 7.2.3.0
2.1.0.4
General
          BUGFIX: 00357512 Directory name conflict
          BUGFIX:       Contact card incorrectly displayed detail view
2.1.0.3
General
          UPDATE:        Audit viewer not translated
2.1.0.2
General
          UPDATE:        Language resources updated 2019-01-16
2.1.0.1
General
        BUGFIX:          Phone list context menu not translated
        BUGFIX:          00345909, Abc-a disconnected on frozen Ldap query
        UPDATE:          Language resources updated 2018-12-28
Feature: OXE
        UPDATE:          Fast call settings updated, tristate used instead of hidden check box
        UPDATE:          Phone list entries grouped on called/calling number
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 51/143
2.1.0.0
General
          NEW: Audit trail
          NEW: BLF pane background image
          NEW: Play wav file on incoming call
          NEW: Directory search selection
          NEW: Automatic logon after abca failure
          NEW: Callers name and entity added to PhoneList
          UPDATE:       Segoe UI used as default font.
          UPDATE:       Default loglevel set to None
2.0.0.17
General
        BUGFIX:          00345909, Abc-a disconnected on frozen Ldap query
Feature: OXE
        UPDATE:          Abcacom.exe updated to 7.2.3.0
2.0.0.16
General
        BUGFIX: Result columns persist regardless of returned searchdata
        BUGFIX: Last result column allowed to be unchecked
        BUGFIX: Retrieved mappable columns added dynamically to user settings
        BUGFIX: Contact card toolbar sometimes incorrectly resized
UD General:
        UPDATE:        EE preserve all search requests except 'Image' for repeat operations
2.0.0.15
General
        BUGFIX: 00357512 Directory name conflict
        BUGFIX:       Contact card incorrectly displayed detail view
2.0.0.14
General
        BUGFIX:          00345909, Abc-a disconnected on frozen Ldap query
2.0.0.13
General
        BUGFIX:          00343919, Unable to copy the “contact card settings” from 4059EE
15.2.1.2 Disable Oxe phonebook ldap overflow when 4059ee performs a call by name query
Until OXE release M3, OXE doesn’t have an option to control the overflow to LDAP server for the dial by name
request from 4059EE attendant. From M4, the system option “LDAP Direct Access 4059” is modified as “4059
Directory Search” to have the control to disable the overflow to LDAP server for the dial by name request from
4059EE attendant.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 52/143
This feature allows the administrator of OXE to disable the overflow to LDAP server for the dial by name
request from 4059EE attendant.
Existing Behavior
4059EE attendant has an option to contact LDAP server directly for dial by name request. In this case,
attendant will get the same result twice for a dial by name request, one from OXE (overflowed to LDAP server)
and another one from LDAP server directly.
The system option “LDAP Direct Access 4059” is of Boolean data type and can be configured as True/False.
* If set to True, OXE will search directly in LDAP server instead of searching in local directory.
* If set to False, OXE will search first in local directory, if no result found for the request then it will be
overflowed to LDAP server.
Enhancement
For this feature the name of the system option is modified to “4059 Directory Search” and the data type is
changed & can hold values 0/1/2.
     If set to “in local dir and LDAP(overflow)” (0), OXE will search in the local directories and LDAP server
         (overflow) for the dial by name request from 4059EE attendant.
     If set to “in LDAP server” (1), OXE will search directly in the LDAP server for the dial by name request
         from 4059EE attendant.
     If set to “in local directory” (2), OXE will only search in the local directories for the dial by name
         request from 4059EE attendant.
Note: The external number dialed by 4059EE attendant which is received from LDAP server (8770 application)
should have proper trunk group seizure prefix added with the number. If the number does not have proper
prefix then OXE will throw the error “Wrong number”.
15.2.1.3 Greeting guide when calling Hunt Group
This feature provides the possibility to play a dynamic voice guide (like presentation guide) instead of ring
back tone to the internal caller while calling to the hunt group. Feature do not concern external calls!!
For this feature, a new parameter “Greeting Guide” is introduced in the hunt group configuration to configure
the guide number which will be played to the caller. The default value of this parameter is 0.
· If the guide number is 0, then ring back tone is played to the caller while calling to the hunt group.
· If a valid guide number (static or dynamic) is configured, then that guide is played to the caller while calling
to the hunt group.
In “Network Hunt Group”, the configured guide should be present in the network nodes with same guide
number.
Note: A backup tone must be configured if there is no voice guide in the media gateway.
The hunt group rotational timer 36 needs to be configured as multiples of voice guide duration to avoid the
interrupts while playing the guide to the caller.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 53/143
15.2.1.4 Hunt group should take care of "busy camp-on" setting of user in multiline
    configuration
Existing Behavior
A multiline user of a hunt group can have one incoming call in each of their lines.
If the system parameter “No Multi-line call in PCX” is set as 0, irrespective of the type of call (personal/group)
with which the user is busy with the first line, the second incoming call will reach the user and it will be ringing
in the second line.
If the system parameter “No Multi-line call in PCX” is set as 1 and the user is busy, irrespective of the type of
call (personal/group) with which the user is busy with the first line, then the incoming call will reach the next
user in the group. If all the other sets are busy, then the call will anyhow show up on a multiline key on this
set.
Waiting and overflow mechanism
When the call can’t be distributed on a set, then parameter "Authorized Camp on calls %" is considered. It
determines the number of calls that can be camped on and calls will wait accordingly. When the number of
“authorized camp on calls” is reached,
then overflow of hunt group is followed. This waiting and overflow mechanism has not been changed with this
feature
      Example with “No Multi-line call in PCX” =1
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14     TC2632en-ed.06
Copyright © ALE International 2020                                                                     page 54/143
Consider a hunt group A with two multiline users X and Y.
· If both users are busy with a call on one of their lines and a 3rdhuntgroup call reaches huntgroup A, the call
will be routed to 2nd multiline of user X.
· If user X is busy with 2 calls and user Y is busy with one call, the 4th huntgroup call will be routed to 2nd
multiline of user Y.
If user X is busy with 2 calls and user Y is busy with 2 calls, then the 5th huntgroup call will be routed to
waiting and overflow mechanism.
Enhancement
Since the incoming calls are waiting in the second or other multiple lines of the multiline user, there are many
chances of losing those waiting calls unattended till the first call ends.
In order to keep the multiline users of the hunt group busy with one call, a new value of 2 has been
introduced to the existing system parameter “Multi-line call in PCX” and the name of the system parameter
has been changed to “No Multi-line call in PCX”.
The value of the parameter “No Multi-line call in PCX” is defined in the following table.
Values and their corresponding definition of the parameter
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 55/143
Example with “No Multi-line call in PCX” = 2
Consider a hunt group A with two multiline users X and Y.
    If both users are busy with a call on one line and a 3rdhuntgroup call reaches huntgroup A, the call
       will follow waiting and overflow mechanism.
Restrictions
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 56/143
-   This feature is applicable for the hunt group types cyclic and sequential, but not parallel.
-   When system parameter “No Multi-line call in PCX” is configured as “2”, the call will not reach the tandem
    set, when the other tandem is busy, irrespective of tandem partial busy parameter.
-   When system parameter “No Multi-line call in PCX” is configured as “2”, the priority call configuration is
    not recommended. If configured, calls will be placed on the multi-lines as per already existing architecture.
Management
System Parameter “Multi-line Call In PCX”:
- The existing parameter “Multi-line Call In PCX” of type “Boolean” has been changed to “No Multi-line Call In
PCX” with type “Enum” in the menu “System” with a default value “1”.
Parameter Name: No Multi-line Call In PCX
Parameter Path: mgr-> System R/M -> No Multi-line Call In PCX
Values: 0/1/2
Default Value: 1
15.2.1.5 LDAP overflow using LDAPS
Service provided by the feature
To provide an option to secure the connection between OXE Telephone Server and LDAP Directory Server.
This can be possible using following two ways:
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 57/143
        To support the use of URL schema, “ldaps:\\...”, that directly connects to the secured port 636 on
        LDAP Server.
        To support LDAP over TLS that establishes LDAP connection in clear mode on default port (389) and
        switch into a secure TLS connection
The Call-By-Name feature in OXE provides a service to search the external directory from the Call Server
through an overflow from the current phonebook through LDAP. The external server is called as LDAP server.
This is possible through a softkey “search book” which gives direct access to the external directory search
from the user terminal. If search hits are found in the local phone book, then this key permits to trigger a
search for an UA user. If no hits are found on the local phone book, then it’s automatically done on the
external server. Only telephone numbers that comes from the search on the external directory is processed.
Existing Behavior
The existing connection between the OXE Telephony Server and the LDAP Directory Server uses clear mode of
connection to communicate (refer Fig 1). Using the clear mode of connection to the LDAP Directory server
does not provides a secure connection. Likewise, a number of LDAP servers can communicate to the OXE
through unsecured connection (anonymous).
Enhancement
The enhancement of the feature includes OXE Telephony server to use a secure connection to LDAP Directory
Server. The connection must be secured by TLS (refer Fig 2). There are two ways to secure LDAP connections
with SSL/TLS:
     LDAP connections that needed to be secured are handled on a separate secured port, typically 636.
        The entire connection is wrapped with SSL/TLS. This process, called LDAP over SSL, uses the URL
        schema ldaps:// protocol.
     STARTTLS is an alternative approach that is now the preferred method of securing an LDAP
        connection. STARTTLS upgrades a clear connection by wrapping it with SSL/TLS after/during the
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 58/143
        connection process. This allows clear and secured connections to be handled by the same port (This
        utilizes STARTTLS to encrypt connections).
MGR Management
To select the mode of connection, a new option “Mode of Connection” is introduced in mgr->Application -
>LDAP Phone Book which has three values:
     Clear – This mode allows OXE to establish LDAP connection in clear mode on default port (389).
     LDAP over TLS – This mode allows OXE to establish LDAP connection in clear mode on default port
        (389) and switch into a secure TLS connection.
     LDAPS – This mode allows OXE to establish secured LDAP connection on the dedicated server port,
        636 (secured).
PKI Management
For server authentication purpose, it is needed to import the certificate of LDAP server in OXE. Netadmin is
used to import the certificate. (Refer [3])
To save the LDAP server CTL to OXE’s trust store user can go to “netadmin --> 11.Security --> 11. PKI
Management --> 3. Endpoint CTL (Trust Store)”, and provide the file path to the server CTL file, if this path is
not valid then the save operation will fail. The LDAP Directory Server’s CTL file to be imported into OXE must
have the complete CA chain that can verify all the LDAP Directory Server's Certificate during connection. This
information will not be added to OXE’s lanpbx file and it will be available only in OXE’s trust store.
11.11.3.Endpoint CTL (Trust Store)
==================================
1. 'Import Endpoint CTL'
2. 'View Endpoint CTL'
3. ‘Delete Endpoint CTL'
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 59/143
0. 'Previous menu'
What is your choice ?
Fig 3: Display of Endpoint CTL
LDAP Server Management
To enable the remote LDAP server to establish the connection with the OXE over SSL/TLS, below points are
important:
1. LDAP server is capable to establish the connection over SSL/TLS.
2. LDAP server has CA that can be either external or self-signed, which is later imported to OXE’s trust store
list.
3. LDAP server is managed to communicate with OXE over SSL/TLS.
8770 application can be configured as a LDAP server.
Interactions with other OXE releases
LDAP or LDAP over TLS should not be activated on a node within a heterogeneous ABCF network (when all the
nodes in a network are not in the version R 12.3). If done, it requires a manual change in the port number
after diffusion.
15.2.1.6 OMS and PCS interworking support
When a PCS is rescuing an OMS in absence of Main CPU, OMS is going for soft reset (i.e. Voice context are
released but VM is not rebooted) and will connect to PCS. When the Main node comes up the OXE-MS to go
for a hard reset (i.e.VM is rebooted) and connect to PCS.
PCS connection can be established in clear mode or in cipher mode if native encryption has been activated on
the node
15.2.1.7 Sip trunk recording (R12.3.1)
SIP trunk recording is required typically as an alternative to DRLink and T2 recording.
The solution allows a SBC that is between a SIP trunk provider and OXE SIP trunk to fork media to a Recorder
(eg OPCXR). The SIP REC standard is used between the SBC and the Recorder.
The requirement is that OXE generates a Global CAll ID to SBC (through SIP) and to Recorder (through CSTA
monitoring of the called set - Noé or SIP) on an incoming call, so that the recorder can track the call
evolutions (transfer, forwarding, conf call)
This is already done with T2 recording (using Time Slot + Global Call ID)
The solution should work with OPCXR and OTSBC but also with 3rd party recorder and SBC.
Should address both business and CC devices.
15.2.1.8 Voice flow duplication for IP DR Link (R12.3.1)
The aim of this development is to provide the possibility to record the conversation of an IP user by two
different IP DR-Link at the same time in order to secure the recording of conversations in two different IP-
Logger.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 60/143
The limit of only one DR-Link authorized to monitor a specified IP user is cancelled. There is now no limit to the
number of DR-Link authorized to monitor a specified IP user.
Booth DR-Link, which record the same conversation of an IP user, work independently. Each of them
starts/stops his own recording with or without play his own beep or guide.
The only interaction is that if one DR-Link asked first to play a beep or a guide, the request to play a beep or a
guide by the second DR-Link will be accepted without the beep or the guide being really played. In addition, if
the first DR-Link asks to stop playing his beep or guide, the beep, if managed, of the second DR-Link will be
started whereas the guide, if managed, will not be started.
This feature needs a modification of the software of the NOE IP set so that it can send its voice flow to two IP
DR Link at the same time. To limit this impact, it has been decided that this duplication will be available only on
all NOE 3G EE IPTOUCH (8008, 8018, 8028s, 8058s, 8068s, 8078s) with version NOE 3G EE from R500
5.40.09 and from IPDSP version 11.2.0.
There is no new management parameter to enable/disable this feature. If conditions are fulfilled, the
duplication by a second IP DR-Link is available that is to say when an IP DR-Link records firstly the IP user
associated with the right type of NOE set.
Therefore, cases, where duplication is not authorized, are:
       a DR-Link using a TDM-Logger already records the IP user.
       an IP DR-link already records the IP User but the type of his set is not 8008, 8018, 8028s, 8058s,
        8068s, 8078s or IPDSP.
       There is already two IP DR-Link which record conversation of an IP user.
And if an IP DR-Link records firstly an IP user, a TDM DR-Link cannot ask to record this IP user.
For all these unauthorized cases, the service is rejected.
Software lock 130
Depending the value of the software lock 130 named CSTA voice recording type, one NICE (value 1), one DR-
Link (value 2), several NICE (value 3) or several DR-Link (value 4) could be connected to the same OXE.
To be able to execute a voice flow duplication, it is necessary to have at least two IP DR-Link connected to the
OXE. Then the value of the software lock 130 should be equal to 3 (several NICE) or equal to 4 (several DR-
Link). And consequently, when two DR-Link records the conversation of an IP user, they are automatically of
the same type, two NICE or two DR-Link.
Recording Software locks
To record a IP user, an IP DR-Link consumes two locks:
      one for monitoring: PARA_MAO 21 named DR-Link
      one for recording: Software lock 334 named “Max. IP recording”
In the case of a duplication, 2 x each previous locks are obviously consumed. It is therefore important to take
into account this situation during the definition of the software locks by ACTIS for an OXE where voice flow
duplication could be activated.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                    page 61/143
15.2.1.9 Waiting Message Indicator synchronization (R12.3.1)
OXE advanced call-log is not synchronized with MWI, in other terms, an unanswered call can create an
entry in the OXE call-log but will not trigger the MWI on the set. When the call arrives while the user is
away from his desk, nothing will indicate him that he missed a call during his absence.
The request is thus to trigger MWI when a user has unanswered and not yet consulted entries in the
advanced call-log.
Feature description summary
       Existing Behavior:
                 1. All the answered/unanswered calls that have been stored in call log are displayed in regular
                 font. They do not affect the message icon operations and message icon will lit based on non-
                 replied calls list.
                 2. Unanswered calls to a busy set are not stored in the internal unanswered call list and
                 Message icon will not be lit.
                 3. Non-replied calls list are stored only in memory, at reboot they will be lost. When the
                 Telephony comes up again message icon is not lit as the non-replied calls list is empty.
Enhancement:
       1. For a NOE device if the call log access rights are true then the internal/external unanswered calls
       list won’t be available. The message icon is now in synchronization with call log. For a NOE device if
       the call log access rights are false then the internal/external unanswered calls list will be available.
       The message icon is now in synchronization with internal/external unanswered calls.
       2. If the user has not accessed the unanswered calls at least once, those entries will be displayed in
       “bold font” in the call log, once accessed into call log detailed view the font will be changed to regular.
       3. Incoming unanswered call to an idle set is stored in the advanced call log and Message icon will be
       lit.
       4. Incoming calls for busy sets (by CROXE-3916) and OOS sets (by CROXE-6875), call record will be
       stored in advanced call log and Message icon will be lit.
       5. The call log is stored in database and memory also. Since it is available in database, it will be
       loaded in to memory after reboot. So the message icon status will be retained even after reboot.
Restrictions:
       Synchronization of OXE MWI and advanced call-log feature will be limited for NOE sets.
15.2.2 CCD
15.2.2.1 Support of 8019s – Leftovers (proACD agent)
With this feature, 8019 sets will support Pro-ACD (tested on CCS version 10.9.93.0)
15.2.2.2 Integrated Call Log on CCD Operator
The aim of this development is to provide the OXE Integrated Call Log feature to CCD agents logged on all
types of Pro-ACD NOE set and all types of Pro-ACD DECT. To this, business Call Log must be added Call Logs
associated to specific CCD use cases on CCD agents.
Note that the feature “Long press on green button to get in to call log menu in AGAP DECT set” is available on
DECT CCD agents
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 62/143
15.2.3 Cloud Connect/Fleet dashboard
15.2.3.1 Remote management capabilities through Fleet Dashboard (NOT released in
    R12.3.1)
 A remote connection to the OXE is possible with the fleet dashboard. Management & maintenance will be
possible as well as with a regular system terminal.
History of those remote connections will be implemented in a further version of the Fleet DB (history details
not on oxe side).
The terminal is not detachable.
Vertical scrolling bar is present but not horizontal.
A valid SPS contract must also be activated for the concerned system.
15.2.4 Dect
15.2.4.1 SUOTA on 82X2 DECT handsets
This functionality provides the possibility to upgrade DECT handsets software over the air.
Only one communication channel can be opened at a time with a handset. Audio communication is preferred
over downloading; that means that a software download is stopped during an audio communication and will
resume later.
The load of the DECT system is considered to decide the order of the downloads and the number of
downloads that can be done in parallel. The number of simultaneous downloads on the same base station
must be limited to keep free slots for voice calls.
Tools:
Tools are provided to display information about the handsets firmware, the downloads in progress and to
allow to download a specific handset or a group of handsets.
Tool to use is “downstat m” with the following menus:
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 63/143
Another tool: the field FWU shows a download in progress
(604)xb006004> dectview com
Wed Mar 20 16:41:11 CET 2019
================= DECT RESOURCES BUSY STATE ===============
Resource         Max      busy free percent busy
-----------------------------------------------------
Link          1101 49           1052            4.45
LCEI           1050 49           1001            4.67
ADPCM            160      1       159             0.62
Buffer UA-> 510            0      510             0.00
====== There are 49 Communication(s) running ========
Link/State : 517/STABLE CC/MM/FWU/SECU :1/0/1/1 RELAY : 2/0/134 PORT 32024 RADIO = 2/0/134
DR3FN9 Num:21862757
Link/State : 772/STABLE CC/MM/FWU/SECU :1/0/1/1 DLEI/BS: 120/0 MAC: 12/09/124 LCEI: 1005 ADPCM:
X/XX/XX Num:21863571
Link/State : 566/STABLE CC/MM/FWU/SECU :1/0/1/1 RELAY : 2/0/147 PORT 32032 RADIO = 2/0/147
GA5FN5 Num:21861680
The handsets switch on the new downloaded software version ONLY when they are put on a charger cradle.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 64/143
            SUOTA is activated in oxe management:
            mgr -> PWT/DECT System -> R/M -> Allow auto FW update of sets
            As soon as it is set to YES the download will start
Important    Notice:
             SUOTA can only operate with minimum dect sets firmware when presence of EHO or dect2.4.4HB boards
             Compatibility with EHO (External Handover): on a customer site configured for EHO, 82x2 DECT
             handsets must have a minimum SW version to operate correctly during the download of the SW over the
             air. If SUOTA is enabled on a site where External handover is activated and firmware versions of the DECT
             handsets are "old", DECT end users will lose some functionality during the SW download step of the SUOTA
             process:
                 o     incoming calls are working correctly: the download is paused in order to be able to take the
                       incoming call.
                 o     EHO is transparent to the user
                 o     BUT it is not possible to do any action on the handset (go in menu, do an outgoing call)
                  deactivate External Handover (EHO), during all the SUOTA phase, if DECT handsets don't have the
                   right SW version (it is the case for all customer site systems). This management is dynamic.
                 Once the firmware upgrade is done EHO can be put back to its original state & this operation will NOT
                 be done again with further firmware.
                 Minimum SW versions for compatibility with EHO
                                        Minimum SW version (compatibility with
                   DECT Handset
                                        EHO)
                   8212                 v0011b0002
                   8232                 v4283b0001
                   8242                 v6282b0002
                   8262                 v5581b0001
                   8262Ex               v7581b0001
                 In case of EHO and older SW versions, the SW upgrade strategy with the customer could
                 be:
                     o Either temporarily deactivate EHO at the customer site until all 82x2 handsets have been
                        upgraded (loss of handover).
                     o Either keep EHO activated and accept the temporary functional impact (outgoing calls not
                        possible, no access to the menu of the sets).
                     o Either manually upgrade 82x2 SW (and SUOTA will be possible next time)
            OmniPCX Enterprise - Release 12.3.1
            Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
            Copyright © ALE International 2020                                                                   page 65/143
              Once the sets are upgraded EHO can be set to YES again & you will not have to do that again
              for the future downloads. With the version contained in the actual oxe the restrictions are
              removed.
 Compatibility with Dect2/4/4HB
 See below the minimum firmware versions of the sets which can do SUOTA when radio connected to these
 boards
                            1st version supporting correct 63 bytes
       DECT Handset         management (compatibility with
                            Dect2/4/4HB boards)
       8212                 v0010b0002
       8232                 v4183b0002
       8242                 v6182b0002
       8262                 v5481b0003
       8262Ex               v7481b0003
 System error messages (“incvisu”) of DLC type can be seen in this case.
 New Software activation: Once the new SW version has been downloaded in the 82x2 handset, the
 handset must be put in its charger to automatically switch to the new SW version.
SUOTA Status: some explanations
Some explanations on columns “Download status” & “Note”
Example of result for last columns:
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 66/143
Download status is represented by the 2 last columns.
“download status” has 3 important fields:
    1. Mode (A, X, M)
           a. A Automatic download: the set is in automatic mode. System automatically updates the set if
               it is not in the current pbx release.
           b. X This set is excluded from automatic mode. It will NOT be updated by the system.
           c. M The set was excluded from the automatic mode. A manual download was launched through
               “downstat m” menu 4.
    2. Percentage: either 0.0% if the set has no current download or the actual percentage of progress.
    3. Automaton state: a label that is just showing the state of download.
           a. IDLE: virtual state for a bigger real state. The set stays like this until the system decided to
               load a new firmware. Can mean that the set is powered off or is out of coverage …
           b. ERASE REQUESTED: system asked to the set to prepare the memory flash zone for the new
               firmware downloaded. Eventually telling to put the set back on his cradle: "charger required".
           c. WRITING: system is in the phase of downloading the new firmware
           d. PAUSED: temporarily stopped for seral reasons … (like the set is not available for the
               moment, out of coverage, in communication …) The system is waiting to continue the upload
           e. WAIT FOR FLASHING: indicates that the system asked to the set to start the new firmware.
               The set needs to be put on his cradle & powered on.
           f. ERROR: the protocol failed in automatic mode & the set will be downloaded again later.
               There is not further information.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 67/143
            Duration of the SW upgrade: Due to the low bandwidth data channel used, it takes several hours for each
            handset to download a new SW version. The download process cannot take more than half of the channels
            per station.
            Hereafter is an estimated information of the time to upload. Those durations are given under best traffic
            conditions.
            SUOTA is interrupted if the handset is in use & too many channels on base stations are used.
            Download duration depends on the handset activity, base stations activity, handset localization
                                    Binary size to
                                       upload            Estimated upload time
             Dect handset              (1 Mb)                (best situation)
                  8212                   0,9                       ~ 6h
                  8232                    1                        ~6 h
                  8242                    2                       ~9h
            8262/62EX/BGR                1,7                       ~ 9h
            Duration of the global upgrade process for a complete site: It is difficult to estimate the total amount
            of time needed to upgrade all 82x2 DECT handsets to new SW versions as it depends on several parameters:
                 o Ratio of the number of handsets to the number of base stations
                 o Flat distribution of the 82x2 handsets over the base stations or concentrated under a few ones.
                 o Ratio of 8232 handsets which are a little slower to download the SW
                 o Reserved channels for alarms activated or not
            Due to that fact the total duration on a site could take a whole week.
            Retrieving versions of the sets: use the following mtcl command to view the versions of the compatible
            dect sets (no MRxxx) & how many there are
            dectsets | grep -E "V." | grep -v MR | awk '{FS=" "}{print $(NF - 3)" "$(NF - 2)}' | sort | uniq -c
            example of output:
Important    Allow auto FW update of sets: SUOTA is set to YES for a new database & does not change its state
             during translation.
            15.2.4.2 Campus
            Campus feature can be used now with xBS like it was before with other base stations.
            OmniPCX Enterprise - Release 12.3.1
            Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
            Copyright © ALE International 2020                                                                   page 68/143
15.2.5 Infra
15.2.5.1 Filtering of OXE events sent to 8770
After management of objects like subscribers, phone book, CCD or a device changing of state (ie. forwarding)
MAO sends events to some subscribed processes, like the 8770. But some events are not useful, so this new
feature is done to not send useless events.
Configuration Procedure
"New attribute Event filter” in object “mgr->Event Routing Discriminator”.
The change of the attribute is taken into account dynamically.
The default value is “No” (false).
15.2.5.2 Software Orchestration Tool R2.2
New version of the S.O.T. installation tool bringing bug fixing & new features like virtual machines templates.
See “TC2456en” for features description & system documentation
“SOT_2.2_im_Manual_8AL90559USAD_1b_en.pdf”
15.2.5.3 Spectre/Meltdown security issues – Kernel patch (R12.3.1)
In 2017 and 2018, several vulnerabilities have been discovered, around the Intel processor, allowing attackers
to obtain data from kernel part, breaking the old separation between user and kernel rings.
The CVE board (Common Vulnerabilities and Exposure) introduces several identifiers, each of them
representing a vulnerability:
     CVE-2017-5715 – Spectre V2
     CVE-2017-5753 – Spectre V1
     CVE-2017-5754 – Meltdown
15.2.5.4 Support of Microsoft Hyper-V
Recommandations
   - For better performance, it is recommended to keep core C-state (Power Management State) disabled
     in bios. (Core C-state terminology may differ depending on the server)
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 69/143
    -   Generation 1 virtual machines to be used for OXE and OMS operating system installation, as
        Generation 1 supports 32bit and 64-bit guest operating system.
    -   Hard disk controller type needs to be “IDE controller” for Hyper-V OXE and OMS virtual machine
        installation, and not with “SCSI controller”.
    -   Use only SOT (Software Orchestration Tool) for installing Guest VM’s on Hyper-V.
    -   Legacy Network Adapter to be used for network–boot installation in Hyper-V.
    -   For the QoS (Quality of Service) configuration, select “Legacy Network Adapter” for OXEVM in Access
        mode, and select “Network Adapter” for OMSVM in Trunk Mode.
15.2.5.5 Support of VMware encryption and VMware motion with OXE-V & Support of
    VMware Release R6.7
The goal of the feature is to qualify the performance of OXE, OMS and OST64 in VMware 6.7 release with
normal and encryption storage policy.
15.2.6 Maintenance
15.2.6.1 “cryptcheck”: a new tool to check encryption data coherency
“cryptcheck” is a new tool that can be used to check encryption & sip coherency. It is now embedded in
infocollect 5.8
Example of output:
(699)xb006099> cryptcheck
cryptcheck command options
      -h|H|?    Display this usage
      -a      Check all
      -l      Check all links
      -g all   Check all gateways
      -g #      Check this gateway
      -t #     Check the gateway by its trunk number
      -r      Resume the check all (display only anomalies)
*** Version: 0.0.2 ***
(699)xb006099> cryptcheck -a
--------- System parameters (for native encryption) ----------------
* Other Param/Native Encryption Parameters - Enable Native Encryption -       *
    Native Encryption is 'activated'
* Other Param/native encryption Parameters - Authentification for SRTP -     *
    Authentification fo SRTP is 'Unauthenticated'
!!! ERROR - Incompatibility with activation of 'Native Encryption'
* Other Param/native encryption Parameters - Enable Mutual TLS Authentication - *
    Mutual TLS Authentication is 'Disable'
* Other Param/SIP Parameters                - SRTP offer answer mode -     *
    SRTP is 'not activated'
* Other Param/SIP Parameters                - Enhanced codec negotiation - *
    Enhanced codec negotiation is 'Network Type'
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 70/143
--------------------------------------------------------------------
--------- Check SIP external gateways ------------------------------
=====================================================
| SIP EXTERNAL GATEWAY To_ICE                    #001 |
=====================================================
+
+             - Update Management -
+       SDP in 18x             : False
+       incoming calls 100 REL : Not Requested
+       outbound calls 100 REL : Supported
+
+       Remote domain             : sip-xxxxx.com
+       Use trunk group number : 995 (ABC-F)
+       Type Of Codec Negotiation : Default
+       Port number             : 5260
+       Transport type          : TCP
+       Media                : RTP only
…
=====================================================
| SIP EXTERNAL GATEWAY WRG                   #005 |
=====================================================
+
+           - Update Management -
+     SDP in 18x            : False
+     incoming calls 100 REL : Not Requested
+     outbound calls 100 REL : Supported
+
+     Remote domain            : xx.xx.xx.xx
+     Use trunk group number : 994 (ISDN)
+     Type Of Codec Negotiation : SingleCodecG711
+     Port number            : 5060
+     Transport type         : UDP
+     Media               : RTP only
  !!! ERROR - Session timer method for the SIP Gw should be 'UPDATE'
--------------------------------------------------------------------
*** Version: 0.0.2 ***
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 71/143
15.2.6.2 DNS tools “host”, “dig” & “nslookup” (R12.3.1)
Extract from “linux.die.net” …
Tool “dig”
dig (domain information groper) is a flexible tool for interrogating DNS name servers. It performs DNS
lookups and displays the answers that are returned from the name server(s) that were queried. Most DNS
administrators use dig to troubleshoot DNS problems because of its flexibility, ease of use and clarity of
output. Other lookup tools tend to have less functionality than dig …
Tool “host”
host is a simple utility for performing DNS lookups. It is normally used to convert names to IP addresses and
vice versa. When no arguments or options are given, host prints a short summary of its command line
arguments and options.
Tool “nslookup”
Nslookup is a program to query Internet domain name servers. Nslookup has two modes: interactive and
non-interactive. Interactive mode allows the user to query name servers for information about various hosts
and domains or to print a list of hosts in a domain. Non-interactive mode is used to print just the name and
requested information for a host or domain.
15.2.6.3 Syslog server for xBS
A syslog server is now embedded in the OXE for xBS debug purpose.
By default, is it not started
Management is done through “netadmin”
If the oxe is rebooted the server has to be started again
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 72/143
Activation of local server:
Add a redirection to another syslog server:
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 73/143
Configuration must be updated on twincpu …
15.2.6.4 New editor “nano” (R12.3.1)
“nano” can be used replacing “vi”. It is easier to manipulate. Check the internet for a more detailed
explanation.
Below is an example of the use of “nano”
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 74/143
15.2.7 Noe & Sip sets
15.2.7.1 8008/8008CE/8008G 8018/8028s SIP phone on Internet through OTSBC
Consult document “Server_deployment_guide_for_remote_workers_8AL90345ENAAEd:08” for further
explanations & configuration.
Network architecture:
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 75/143
15.2.7.2 8008CE
This is the 8008 set in sip mode without the possibility at boot time to switch in noe mode.
15.2.7.3 8008G
8008G is an IP Touch Set similar to 8018 Set, intended to replace 4018 NOE 2G IP phone and 8001 entry level
SIP devices. New Set 8008G has Gigabit Ethernet capability. No new type in management. Retro-compatible in
releases where 8008 was introduced.
15.2.8 OT
Compatibility with OT 2.5 (with OXE R12.3.1 Tech. Release)
R12.3 was tested with OTC PC Application 2.4.17.000
15.2.9 Security
15.2.9.1 Hashing of administrative OXE passwords in SHA-2/SHA-512 function (MD1)
This feature upgrades the existing hashing (MD5) algorithm into a stronger hashing (SHA512) algorithm to
store OXE user account passwords.
The scope of this upgrade is for OXE user accounts only. This feature is not applicable to SIP passwords,
SNMP passwords, set passwords and passwords other than admin.
The following accounts are upgraded to have strong hashing algorithm to protect the passwords through this
feature.
mtcl
adfexc
swinst
ppp
root
client
ccfexc
Migration to M4
To upgrade from any release to M4 delivery, any of the following procedures can be followed. Examples below
are taken from a migration M3 to M4
Case 1:
1. Backup the Linux database of installed M3 delivery (R12.2).
2. Install the M4 delivery (R12.3) on inactive partition.
3. After the partition switch, restore the Linux database of M3 (R12.2) on M4 (R12.3).
4. Manually change the OXE user account passwords in order to effect the changes in to the new hashing
algorithm (SHA512). Command to use is “passwd”.
Case 2:
1. Install the M4 delivery (R12.3) on inactive partition.
2. Perform Partition duplication (Linux data) from active partition.
3. After the partition switch, manually change the OXE user account passwords in order to effect the changes
in to the new hashing algorithm (SHA512). Command to use is “passwd”.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 76/143
15.2.9.2 NEAN (Native Encryption on ABC Network)
There is no interoperability support for this feature with current IP Touch Security solution
Until R12.2 (M3) release, SSM and MSM modules are used to encrypt the IP packets over the network in OXE.
Refer [6] and [8] for more details.
From R12.2 (M3) Native Encryption architecture was introduced to replace the external box based encryption
in stand-alone configuration. DTLS link is used to secure MG and IPP phones. Refer [1] and [2] for more
details.
This feature allows OXE to establish IPsec tunnel between two nodes using IPsec Manager (software
component inside OXE) in order to encrypt the link between them.
Until R12.2 (M3) release, Network encryption in OXE is supported through external boxes. An IPsec tunnel is
created between the boxes that protects OXE. For more details, refer doc [8]. From M4 release onwards, OXE
supports network encryption natively using IPsec, without the help of any other external boxes.
IPsec Manager
New software module is introduced inside OXE to establish the secure IP links (IPsec tunnel). IPsec Manager is
a pure Linux process that interacts with other OXE modules to get the configuration details. BT Link process
interacts with IPsec Manager and provides necessary inputs to enable IPsec manager to establish an IPsec
tunnel between two OXE nodes.
Encryption Icon on an IP Touch Phone
FSNE enabled IP Touch terminals display an icon with lock symbol (Encryption Icon) during conversation.
The encryption icon just indicates whether the IP Touch implements the encryption mechanism. It does not
indicate that the communication is encrypted end to end. For example, if the IP TOUCH is in 3 party
conference, the presence of encryption icon indicates that encryption exists between the IP TOUCH and the
MG where the conference circuit is located; it does not indicate that the phones in the conference are carrying
out encryption.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 77/143
Hence in case of conference/Intrusion, unlike the local scenario, if any unsecured IP set is involved over the
network, then the encryption icon may not be removed on all the involved secured IP sets.
Port Numbers
IPsec Manager use TCP port 2579 for communicating with BTlink process.
OpenSWAN pluto uses port number 500 for IKE/ISAKMP negotiation with its peer.
IP Link Encryption Parameter
The existing parameter Encryption under mgr > Inter-Nodes Links > Logical Links (ABC-F) > Hybrid Link
Access menu is used for this feature also to enable IP hybrid link encryption.
Direct RTP Parameter
“IP > IP Parameters > Direct RTP and IP > IP Parameters > Direct RTP for H323 terminals” must be set to
true.
Encryption Icon Parameter
“mgr > Alcatel 8&9 Series > Alcatel 8&9 classes of service > Phone COS > Display Encrypted Communication”
parameter allows to display on FSNE enabled IP Touch terminals, a specific conversation icon for encrypted
communications.
SRTP Authentication Parameter
The SRTP Authentication parameter under “mgr >System > Other system Param > Native Encryption”
Parameters should be same on all the involved nodes of the link call.
Incidents
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 78/143
The following new incidents are introduced for this feature:
6100 … 6106
6100:   CRYPTO_UPDATE_CONFIGIPSEC_FAILED
6101:   CRYPTO_IPSEC_TCP_LINK_LOSS
6102:   CRYPTO_IPSEC_CONNECTION_FAILED
6103:   CRYPTO_IPSEC_CONNECTION_SUCCEEDED
6104:   CRYPTO_UPDATE_CONFIGIPSEC_SUCCEEDED
6105:   CST CRYPTO_REBOOT_OF_IPSEC_MGR
6106:   CST CRYPTO_IPSEC_TUNNEL_UP_DOWND
Tools
The following tools that are used for existing network encryption can be used for this feature also.
    -    cryptview
In cryptview tool, the list of secured IP links is displayed.
    -    cryptview com
    -    cryptview all
    -    cryptview tab
To check the status of IPsec tunnels
    -    tunstatus
    -    ipsec service status
The list of configured ABCF links and their status whether IPsec tunnel is up or down between the configured
ABCF links are shown.
The IKE phase 1, IKE phase 2 and tunnel establishment related logs are stored in /var/log/openswan.log. A
maximum of 5 files are retained and files are rotated when it reaches 25 MB.
Restrictions
   -   Interoperability with IP touch security solution (Thales box encryption) in same node and also in
       network nodes is not supported
   -   Even though the signaling link between two nodes is encrypted, the H323 session is not encrypted
       which is the same behavior as in IP touch security solutions.
   -   Calls are established in clear mode for IPv6 devices.
   -   Calls are established in clear mode with IPDECT (Philips/NEC), IP-xBS terminals, SIP extensions,
       voicemail, OT applications.
   -   For seamless set movement between two nodes, the UDP base port must be configured with same
       value on both the nodes under the path “mgr->IP->Descend Hierarchy->TSC/IP Parameters
       ->Review/Modify-> UDP Ports.”
   -   Change in CA/CS certificate in a node require re-establishment of IPsec tunnels with its peers. IPsec
       tunnels in OXE are governed by “Dead Peer Detection (DPD)” mechanism (Keepalive) which detects
       the dead peer automatically based on the timeout values (dpdelay=15s, dpdtimeout=60s,
       keyingtries=3 times). In OXE based on the default DPD timeout values, it could take up to a maximum
       of 10 minutes (approximately) to clean up the existing tunnel with a dead peer. In some cases (IP
       address/certificate change, bascul), it may be required to have a quicker turnaround time for clearing
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 79/143
        up the tunnels. For such cases, the “tunreset” tool can be used in the peers to reset the tunnel and re-
        establish a new one.
15.2.9.3 Native Encryption - Scalability up to 15k (External E-gateway)
To achieve scalability to 15K users in OXE, the encryption Gateway (EGW) is managed in a separate VM
(virtual machine) as External EGW.
The dedicated DL is established between CS and external EGW. This DL is used for UAUDP connection with
EGW and monitor the alive status of EGW. The call server goes for reboot if the connection of external EGW
losses as in the case of Internal EGW.
Endpoint Connection, Node Migration, Media Communications are same as the existing Internal EGW. The only
difference is a dedicated VM is used for EGW.
In case of PCS configuration, Main CS is configured with external EGW to handle up to 15k users and PCS is
configured with internal EGW to handle limited number of users.
To handle large number of users in PCS, External EGW is required. External EGW IP Address for PCS is
configured using parameter “EGW IP Address" of “PCS Addresses” menu in OXE(main).
Restrictions
Feature shall only be available in virtualized system, and then with both CS and EEGW configured behind same
virtual switch. This is applicable for PCS with EEGW also.
IP Ports
Default Listening port for DTLS clients (Both DTLS supported sets & Couplers) is 32643.
This value changes accordingly with Base port configuration in “mgr”.
Installation of External Encryption Gateway
External EGW is installed and configured in OST (OXE Signaling Translator) as a separate virtual machine to
support 15K FSNE users for a CS. In order to ensure security, both CS and External EGW should be configured
in same network. This virtual machine is capable of functioning as either OST64/EGW depending on the user
requirement. For installation procedure refer to system documentation. This gateway has to be installed with
S.O.T. release 2.1 minimum.
15.2.9.4 Native encryption with IPDSP (MD1 feature)
IPDSP softphone is now compatible with Full Software Native Encryption. Minimal version is 11.2.0 (check
updates on the Business Portal).
Management to do (users):
Set Type + IPTouch 8068s
Native Encryption + Enable
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 80/143
Tsc IP User: IP-Softphone Emulation + YES
2 locks are seen when the set is encrypted & another one during an encrypted conversation
See chap. 18.1.1.5 for restrictions
15.2.9.5 SIP trunk TLS 1.2
The TLS 1.2 feature is embedded in the SipMotor OXE process, SIP TLS encryption is now available without
the help of SSM (in Full Software Native Encryption solution)
15.2.10 SIP
15.2.10.1 SIP Trunk TLS for installed base with Thales
The objective of this feature is to support TLS 1.2 and certificates of 4096 bits for SIP Trunk natively while
allowing other devices to work with existing Thales solution.
This feature aims to provide SIP-TLS signaling without the use of IP Touch Security Module
Existing Behavior
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 81/143
OXE with Thales SIP-TLS
At present in OXE, secure SIP Trunk communications with carrier are done by establishing TLS with the use of
SSM Box through the encrypted port 5061. Currently, the SSM Box does not support TLS version 1.2 and
certificates of 4096 bits
Enhancement
     OXE with Native SIP-TLS
From M4, OXE supports encryption natively without using Thales Modules. For SIP Trunk, TLS is addressed
with feature “Native SIP-TLS for SIP trunk” (Refer [1]). The TLS version 1.2 with certificates of 4096 bits is
also supported with this feature. SIP Motor is in charge of establishing TLS link with Carrier.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 82/143
                  Native Encryption of SIP Trunk TLS for Installed Base with Thales
            This feature enables the Native SIP TLS capability in Thales based architecture.
            It provides the facility to secure the SIP trunk by using Thales Module or by Native SIP TLS.
            It also allows existing customers with THALES based encryption architecture, to use their SIP trunk to native
            SIP TLS [1]. Only the SIP TLS is done natively in OXE while other endpoints such as Terminals/Couplers
            continue to be encrypted with the existing Thales module.
            The TLS establishment generally occurs through the default encrypted port 5061. However, when Native SIP
            TLS is enabled in a Thales encrypted configuration, OXE uses 5261 port and the TLS establishment occurs
            through the port 5261.
            A new system option “Use Native SIP TLS” is introduced to select Native SIP TLS. When it is enabled, TLS
            signaling established directly from OXE (SIP Motor) with carrier by bypassing the SSM box.
Important    Note: It is mandatory to configure the OXE destination port as 5261(instead of 5061) in the remote SIP
             entity side (example: as per the figure below, the SBC carrier configuration define OXE port as 5261)
            OmniPCX Enterprise - Release 12.3.1
            Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
            Copyright © ALE International 2020                                                                   page 83/143
The existing license for “SIP TLS with Thales” feature is applicable.
New System Parameter
A new System Parameter “Use Native SIP TLS” has been introduced to differentiate the mode for establishing
SIP-TLS in Thales Based environment.
Note: For a FSNE enabled node, this Use Native SIP TLS cannot be set to TRUE
Parameter Path: mgr -> System -> D/H -> Other System Parameters -> D/H -> SIP Parameters
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 84/143
Netadmin and Certificate exchange
The process of creating a CA, Certificates for OXE is done inside Netadmin for PKI & CTL Management:
Following steps are to be done
Certificate Creation:
In the command netadmin –m (login as root user)
Option 11 -> Security
         Option 11 -> PKI Management
                  Option 1 -> Certificate
                          Option 1 -> Create/Modify CS Certificate
                                  Option 1 -> Internal Certificate (Auto Generated)
                                  Create the certificate
CA Certificate is generated.
Certificate Import in Truststore
The generated CA Certificate must be imported to truststore
15.2.10.2 SIP trunk - filtering of the OXE calling name (R12.3.1)
The Calling name and number is provided in INVITE message based on the details available in OXE. The below
tables narrate the calling name.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 85/143
Calling name        When Display name is available                 When Display name is not available
Basic call          From and PAI headers with Display name         From and PAI headers with Trunk group
                    received in setup                              name if Trunk group name is managed
                                                                   otherwise with constant string “SIP”
Transit case        From and PAI headers with Display name         From and PAI headers with Trunk group
                    received in setup                              name if Trunk group name is managed
                                                                   otherwise with constant string “SIP”
Secret call         From and PAI headers with Display name         From and PAI headers with anonymous
                    received in setup
The “From and PAI” Display name is never empty and currently there is no control to restrict the Display
name.
The calling number is provided in canonical or not based on the OXE configuration and type of calls.
Enhancement
The requirement is to control the calling name and connected name in SIP messages based on system
options.
With respect to the European GDPR law, it must be possible to filter in OXE, the Calling name and Connected
name transmitted on SIP trunk calls. This ensures that the username of OXE extensions are revealed to the
outside world, or not, depending on the configuration
Feature is not available for SEPLOS.
Thanks to a new option “Send user name in SIP” in External gateway object, the calling and connected name
sent on the SIP trunk during calling or answering a call, follow new rules. It can be configured differently
depending on the expected behavior of each External Gateway. There is no more side effect on main SIP
gateway used for internal calls.
Configuration
The new MAO field “Send user name in SIP” in SIP->External gateways object handles how the user name
part of SIP fields “From” and “PAI” in SIP messages are built.
It can have the following values:
         Send user name if available else Trunk Group name
         Send user name if available else user number (default value)
         Send user name if available else empty
         Send Trunk Group name always
         Send user number always
         Send empty always
The ‘old’ existing system option value of “FROM display name” in:
System->Other System Param->SIP Parameters object, (existing since m1.403)
must be used as initial value of the new field “Send user name in SIP” in existing SIP->External gateways
objects.
The old system option “FROM display name” in System->Other System Param->SIP Parameters object
disappears.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 86/143
15.2.11 Terminals
15.2.11.1 Superwideband/ OPUS codec
Existing Parameter Modified for OPUS Super Wideband Support
For OPUS Super Wideband Support, the existing parameters “G722 allowed in Intra-domain” and “G722
allowed in Extra-domain” have been modified.
The modified parameters “G722/OPUS allowed in Intra-domain” and “G722/OPUS allowed in Extra-domain”
are available in the following path:
mgr-> IP -> Descend hierarchy -> IP Domain - >R/M ->All Instances
               Figure 10: mgr display of modified parameters for OPUS Super Wideband Support
G722/OPUS allowed in Intra-domain
The modified parameter “G722/OPUS allowed in Intra-domain” is available in the following path mgr-> IP ->
Descend hierarchy -> IP Domain - >R/M ->All Instances
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 87/143
                         Figure 11: English text for G722/OPUS allowed in Intra-domain
G722/OPUS allowed in Extra-domain
The modified parameter “G722/OPUS allowed in Extra-domain” is available in the following path:
mgr-> IP -> Descend hierarchy -> IP Domain - >R/M ->All Instances
                         Figure 12: English text for G722/OPUS allowed in Extra-domain
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 88/143
OPUS codec choice
When the Direct RTP is possible for a local call between two IPTouchs, the OXE switching selects the OPUS
codec if the following conditions are met.
    For intra-domain call:
        “G722/OPUS algorithm allowed in Intra-domain attribute of the corresponding domain is equal to
         “YES”
        Both IPTouchs support OPUS (SWB) codec (*)
    For extra-domain call:
      “G722/OPUS algorithm allowed in Extra-domain attribute of the corresponding domain is equal to
         “YES”
      Both IPTouchs support OPUS (SWB) codec (*)
(*) The “OPUS allowed” attribute of the corresponding IPTouch is equal to “YES”
The “OPUS allowed” attribute is updated by the IPTouch at initialization time. This attribute is not displayed
by mgr.
Order of priority between OPUS, G722 and G711 codecs
Codec order selection:
       OPUS codec is selected if the corresponding conditions are met,
       Else, G722 codec is selected if the corresponding conditions are met,
       Else, G711 is selected (if “WITHOUT COMPRESSION” is possible).
The selected Codec is sent to IPTouch through START_RTP message.
    Commands to check on the terminal:
     (601)xb006001> ssh -2 -l admin 135.117.64.135
     Warning: Permanently added '135.117.64.135' (RSA) to the list of known hosts.     
[email protected]'s password:
     BusyBox v1.19.4 (2019-06-03 22:06:17 CEST) built-in shell (ash)
     Enter 'help' for a list of built-in commands.
     $
     $ codec 0
     #codec#
     compress OPUS
     vad off
     band narrow
     framing 20 ms
     pktprd 20 ms
     codec OK
     $
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 89/143
        16 OXE COMPONENTS
        Following is the list of all components with their corresponding version.
        It is also possible to consult the “read.me” file included in every static & dynamic patch to find this kind of
        information. Do a text search with the binary name requested. One read.me file contains all the precedent
        patches.
        For instance:
               For the dynamic patch: read.me file of patch “.M” will contain all data from patch “.A” to “.M”. No
                information related to static patches.
               For the static patch: read.me file of patch “.24” will contain all data from patch “.1” to “.24”
        Below is the content of M4.501 deliveries
Component               Version of M4.501.10.f Version of M4.501.12.A Version of M4.501.13 Version of M4.501.14
Name
r_linux                 r_linux26_153.000           r_linux26_153.000         r_linux26_153.000           r_linux26_153.000
r_linux_patch           r_linux26_153.004           r_linux26_153.006         r_linux26_153.010           r_linux26_153.013
r_glibc-4400            r_glibc-4400_001.007        r_glibc-4400_001.007      r_glibc-4400_001.007        r_glibc-4400_001.007
                         r_ramdisk26_patch_153.000 r_ramdisk26_patch_153. r_ramdisk26_patch_15 r_ramdisk26_patch_153.00
r_ramdisk26
                        .002                        000.004                   3.000.004                   0.004
r_lnxswinst             r_lnxswinst_3.43.0          r_lnxswinst_3.46.0        r_lnxswinst_3.48.0          r_lnxswinst_3.50.0
Rainbowagent            4.2.4                       4.2.4                     4.2.6                       4.2.6
r_firmware_CPU8         r_firmware_CPU8_2.0         r_firmware_CPU8_2.0       r_firmware_CPU8_2.0 r_firmware_CPU8_2.0
                        r_bios_cs2_ami_patch_3 r_bios_cs2_ami_patch_3 r_bios_cs2_ami_patch_ r_bios_cs2_ami_patch_
r_bios_cs2
                        EU24009AAAD_12.0       EU24009AAAD_12.0       3EU24009AAAD_12.0 3EU24009AAAD_12.0
r_egw                   r_egw_2.15                  r_egw_2.15                r_egw_2.15                  r_egw_2.15
r_c1nvz32               r_c1nvz32_3.13              r_c1nvz32_3.13            r_c1nvz32_3.13              r_c1nvz32_3.13
r_pcinstall             Removed                     Removed                   Removed                     Removed
r_nddi2                 r_nddi2_2.25                r_nddi2_2.25              r_nddi2_2.25                r_nddi2_2.25
r_tones                 r_tones_2.19                r_tones_2.19              r_tones_2.19                r_tones_2.19
r_intof                 r_intof_1.25                r_intof_1.25              r_intof_1.25                r_intof_1.25
r_ioip                  r_ioip_4.19                 r_ioip_4.19               r_ioip_4.19                 r_ioip_4.19
r_intip                 r_intip_16.25               r_intip_16.25             r_intip_16.25               r_intip_16.25
r_mg_appli              r_mg_appli_46.29            r_mg_appli_46.29          r_mg_appli_46.29            r_mg_appli_46.29
r_ngp3                  r_ngp3_10.05                r_ngp3_10.06              r_ngp3_10.07                r_ngp3_10.07
r_oms                   r_oms_9.06                  r_oms_9.06                r_oms_9.06                  r_oms_9.06
r_ost                   r_ost_5.18                  r_ost_5.18                r_ost_5.20                  r_ost_5.20
        OmniPCX Enterprise - Release 12.3.1
        Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14       TC2632en-ed.06
        Copyright © ALE International 2020                                                                       page 90/143
                    r_noeip_4.33.81 (A         r_noeip_4.33.81 (A         r_noeip_4.33.81 (A          r_noeip_4.33.81 (A
                    (4018) , Z (4008)          (4018) , Z (4008)          (4018) , Z (4008)           (4018) , Z (4008)
                    binaries)/                 binaries)/                 binaries)/                  binaries)/
r_noeip
                    r_noeip_4.33.40 (B         r_noeip_4.33.40 (B         r_noeip_4.33.40 (B          r_noeip_4.33.40 (B
                    (4028), C (4038), D        (4028), C (4038), D        (4028), C (4038), D         (4028), C (4038), D
                    (4068) binaries)           (4068) binaries)           (4068) binaries)            (4068) binaries)
ssm- V4             r_sm_3.3.05                r_sm_3.3.05                r_sm_3.3.05                 r_sm_3.3.05
ssm- V5             r_sm_3.6.03                r_sm_3.6.03                r_sm_3.6.03                 r_sm_3.6.03
ssm- V5m            r_sm_4.1.03                r_sm_4.1.03                r_sm_4.1.03                 r_sm_4.1.03
r_noeipg            r_noeipg_4.34.21           r_noeipg_4.34.21           r_noeipg_4.34.21            r_noeipg_4.34.21
r_noesip            r_noesip_2.12.40           r_noesip_2.12.40           r_noesip_2.12.40            r_noesip_2.12.40
r_noeuax9           r_noeuax9_3.81.80          r_noeuax9_3.81.80          r_noeuax9_3.81.80           r_noeuax9_3.81.80
r_noe3guax9         r_noe3guax9_4.11.32        r_noe3guax9_4.11.32        r_noe3guax9_4.11.32         r_noe3guax9_4.11.32
r_noe8082           r_noe8082_4.51.03          r_noe8082_4.51.03          r_noe8082_4.51.03           r_noe8082_4.51.03
r_noe3gip           r_noe3gip_4.53.21          r_noe3gip_4.53.22          r_noe3gip_4.53.22           r_noe3gip_4.53.22
r_noe3gsip          r_noe3gsip_3.00.50         r_noe3gsip_3.00.50         r_noe3gsip_3.00.50          r_noe3gsip_3.00.50
r_noemipt8_r100     r_noemipt8_r100_6.0.8      r_noemipt8_r100_6.1.2 r_noemipt8_r100_6.1.2 r_noemipt8_r100_6.1.2
r_noemipt_r2        r_noemipt_r2_109.025       r_noemipt_r2_109.025       r_noemipt_r2_109.025 r_noemipt_r2_109.025
r_noemipt_r3        r_noemipt_r3_120.028       r_noemipt_r3_120.028       r_noemipt_r3_120.028 r_noemipt_r3_120.028
r_IPxBS             r_IPxBS_0064.0016          r_IPxBS_0065.0006          r_IPxBS_0065.0008           r_IPxBS_0065.0008
r_noe8008           r_noe80x8S_5.45.05         r_noe80x8S_5.45.17         r_noe80x8S_5.45.17          r_noe80x8S_5.45.20
r_noe8018           r_noe80x8S_5.45.05         r_noe80x8S_5.45.17         r_noe80x8S_5.45.17          r_noe80x8S_5.45.20
r_noe80x8S          r_noe80x8S_5.45.05         r_noe80x8S_5.45.17         r_noe80x8S_5.45.17          r_noe80x8S_5.45.20
r_wbmappli          r_wbmappli_1202.1810       r_wbmappli_1202.1810 r_wbmappli_1202.1810 r_wbmappli_1202.1810
r_noe8088           r_noe8088_5.05.21          r_noe8088_5.05.21          r_noe8088_5.05.21           r_noe8088_5.05.43
r_sip800            r_sip8008_1.51.03          r_sip8008_1.51.03          r_sip8008_1.51.03           r_sip8008_1.51.03
r_sip8018           r_sip8018_1.51.03          r_sip8018_1.51.03          r_sip8018_1.51.03           r_sip8018_1.51.03
r_sip80x8S          r_sip80x8S_1.51.03         r_sip80x8S_1.51.03         r_sip80x8S_1.51.03          r_sip80x8S_1.51.03
r_ibs_appli_ng      r_ibs_appli_ng_53.02       r_ibs_appli_ng_53.02       r_ibs_appli_ng_53.02        r_ibs_appli_ng_53.02
r_dect8212          r_dect8212_0013.0002       r_dect8212_0013.0002       r_dect8212_0013.0002 r_dect8212_0013.0002
                                                                 r_dect8232_4583.000
r_dect8232          r_dect8232_4483.0004       r_dect8232_4483.0004                   r_dect8232_4583.0003
                                                                 3
                                                                 r_dect8242_6582.000
r_dect8242          r_dect8242_6482.0004 r_dect8242_6482.0004                         r_dect8242_6582.0002
                                                                 2
                                                                 r_dect8262_5981.000 r_dect8262_5981.000
r_dect8262          r_dect8262_5881.0004 r_dect8262_5881.0004
                                                                 2                    3
                    r_dect8262EX_7881.000                        r_dect8262EX_7881.00 r_dect8262EX_7881.00
                                          r_dect8262EX_7881.0004
r_dect8262_EX       4                                            04                   04
     Other product Version
    OmniPCX Enterprise - Release 12.3.1
    Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14       TC2632en-ed.06
    Copyright © ALE International 2020                                                                       page 91/143
                                           DAP firmware for 4080 Access Point: 4910b630.dwl
               IPDECT R170                 DAP firmware for 8340 Access Point: 4920b630.dwl
                                           DAP loader package: 4992030a.dwl
                                           DAP controller versions: 6.21.0299
               8770                        4.1.10.00
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 92/143
17 COUNTRIES IN WHICH RELEASE 12.3.1 IS TECHNICALLY RELEASED
OmniPCX Enterprise Release 12.3.1 concerns the countries mentioned in the table below.
The availability of IP Touch Security Solution for these countries is mentioned in the Logistic and Customs
product information document, which is available on Business Portal, in the right column "Related documents".
In this document, specify the market and the product line, then click on "Update item list" button: the columns
specific to IP Touch Security solution have a red header (columns from "Main origin" to "CCATS").
                                   Country Installation OmniPCX Enterprise R12.3
                          Market                                         System Software to be used
                                                            Installation
                 Market                                                                     ISO Country code
                               Market Country name          initial to be      Bdd
                  Code                                                                         Reminder
                                                                used
           1                 Afganistan                                                           AF
           2                 ÅLAND ISLANDS                                                        AX
           3   BU            Albania                              pl            PL                AL
           4   GM            Algeria                              dz            DZ                DZ
           5                 American Samoa                                                       AS
           6                 Andora                                                               AD
           7   GY            Angola                               pt            PT                AO
           8                 Anguilla                                                             AI
           9                 Antartica                                                            AQ
          10                 Antigua and Barbuda                                                  AG
          11   KF            Argentina                            ar            AR                AR
          12                 Armenia                              ro            RO                AM
          13                 Aruba                                                                AW
          14   KN            Australia                            as            AS                AU
          15   CF            Austria                              au            AU                AT
          16   DE            Azerbaijan                           ru            SU                AZ
          17                 Bahamas                                                              BS
          18   FL            Bahrain                              bh            BH                BH
          19   EH            Bangladesh                           bd            BD                BD
          20                 Barbados                                                             BB
          21   AS            Belgium                              be            BE                BE
          22   AT            BELGACOM BELGIUM                     be            BE                BE
          23                 Belize                                                               BZ
          24   GB            Benin                                ci            X1                BJ
          25                 Bermuda                                                              BM
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 93/143
          26                 Bhutan                                                               BT
          27   DG            Bielorussia                          ru            SU                SU
          28   JZ            Bolivia                              ln            LN                BO
          29   DX            Bosnia and Herzegovia                yu            YU                BA
          30                 Bostwana                                                             BW
          31                 Bouvet Island                                                        BV
          32   KG            Brazil                               br            BR                BR
                             Brithish Indian Ocean
          33                                                                                      IO
                             Territory
          34                 Brunei Darussalam                                                    BN
          35   BV            Bulgaria                             bg            BG                BG
          36   GA            Burkina Faso                         ci            X1                BF
          37   GZ            Burundi                              ke            X1                BI
          38   EN            Cambodia                             kh            KH                KH
          39   GW            Cameroon                             x1            X2                CM
          40   JD            Canada                               us            US                CA
          41                 Cape Verde                                                           CV
          42                 Cayman Islands                                                       KY
          43   HA            Central African Republic             x1            X1                CF
          44   GR            Chad                                 x1            X1                TD
          45   KH            Chile                                cl            CL                CL
          46   DZ            China (PRC)                          cn            CN                CN
          47                 Christmas Island                                                     CX
          48                 Cocos Island                                                         CC
          49   KJ            Colombia                             co            CO                CO
          50   GT            Comoros                              fr            FR                KM
          51   GU            Comores Rep Isl.                     fr            FR
          52   HB            Congo                                x1            X1                CG
                             CONGO, THE Dem REP OF
          53 HB                                                   x1            X1                CD
                             THE
          54                 Cook Islands                                                         CK
          55   JJ            Costa Rica                           cr            CR                CR
          56   GX            Cote D'ivoire                        ci            CI                CI
          57   DH            Croatia                              hr            HR                HR
          58   JK            Cuba                                 ln            LN                CU
          59   CW            Cyprus                               cy            CY                CY
          60   BZ            Czech Republic                       cz            CZ                CZ
          61   AR            Deutsch Telecom                      ge            GE                DE
          62   AV            Denmark                              de            DE                DK
          63   GV            Djibouti                             x1            X1                DJ
          64                 Dominica                                                             DM
          65   JV            Dominican Republic                   ln            LN                DO
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 94/143
          66                 East Timor or TIMOR-LESTE                                            TP
          67   KK            Ecuador                              ec            EC                EC
          68   FD            Egypt                                eg            EG                EG
          69   JL            El Salvador                          se            SE                SV
          70                 Equatorial Guinea                                                    GQ
          71                 Eritrea                                                              ER
          72   DJ            Estonia                              ee            EE                EE
          73   HC            Ethiopia                             et            ET                ET
          74                 Falkland Islands                                                     FK
          75                 Faroe Islands                                                        FO
          76                 Fiji                                                                 FJ
          77   CJ            Finland                               fi           FI                 FI
          78   AA            France                               fr            FR                FR
          79   AK            France                               fr            FR                FR
          80   ze            France Telecom                       fr            FR                FR
          81                 French Guiana                        fr                              GF
          82   LA            French Polynesia                     pf            PF                PF
          83                 French Southern Territories          fr            FR                TF
          84   HD            Gabon                                x1            X2                GA
          85   GC            Gambia                               sn            X1                GM
          86                 Georgia                              ru            SU                GE
          87   AP            Germany                              ge            GE                DE
          88   GD            Ghana                                ci            X1                GH
          89                 Gibraltar                                                            GI
          90   BB            Greece                               gr            GR                GR
          91                 Greenland                                                            GL
          92                 Grenada                                                              GD
          93   KV            Guadeloupe                           fr            FR                GP
          94                 Guam                                                                 GU
          95   JM            Guatemala                            ln            LN                GT
          96   GE            Guinea                               x1            X1                GN
          97                 Guinea Bissau                                                        GW
          98   KW            Guyana                               fr            FR                GY
          99   JN            Haiti                                ln            LN                HT
         100                 Heard Islands and Mcdonald                                           HM
         101   JP            Honduras                             ln            LN                HN
         102   ED            Hong Kong                            hk            HK                HK
         103   BW            Hungary                              hu            HU                HU
         104   CX            Iceland                              de            DE                IS
         105   EY            India                                in            IN                IN
         106   EM            Indonesia                             ii           ID                ID
         107   FS            Iran                                 ir            IR                IR
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 95/143
         108                 Iraq                                                                 IQ
         109   BD            Ireland                              ie            IE                IE
         110   FT            Israel                                il           IL                 IL
         111   BF            Italy                                 it           IT                IT
         112   BG            Italia Telecom                        it           IT                IT
         113   JR            Jamaica                              ln            LN                JM
         114   EE            Japan                                jp            JP                JP
         115   FU            Jordan                               x1            X1                JO
         116   DL            Kazakhstan                           ru            SU                KZ
         117   HF            Kenya                                ke            KE                KE
         118                 Kiribati                                                             KI
         119                 Korea DPR                                                            KP
         120   FH            Kuwait                               kw            KW                KW
         121                 Kyrgystan                            ru            SU                KG
         122   EP            Laos                                 la            LA                LA
         123   XE            Latin America                        ln            LN
         124   DN            Latvia                                lv           LV                LV
         125   FJ            Lebanon                              lb            LB                LB
         126                 Lesotho                                                              LS
         127                 Liberia                                                              LR
         128   FE            Libyan Arab Jamahiriya               x1            X1                LY
         129                 Liechtenstein                                                        LI
         130   DP            Lithuania                            lt            LT                LT
         131   BK            Luxembourg                           lx            LX                LU
         132                 Macau                                                                MO
         133   HG            Madagascar                           fr            FR                MG
                             MACEDONIA, THE FORMER
         134 DW                                                   pl            PL
                             YUGOSLAV REPUBLIC OF                                                 MK
         135   HH            Malawi                               za            X1                MW
         136   ET            Malaysia                             my            MY                MY
         137   FA            Maldives                             mv            MV                MV
         138   GH            Mali                                 sn            X1                ML
         139   CZ            Malta                                mt            MT                MT
         140                 Marshall Islands                                                     MH
         141   KX            Martinique                           fr            FR                MQ
         142   GJ            Mauritania                           sn            X1                MR
         143   HK            Mauritius                            fr            FR                MU
         144   KY            Mayotte                              fr            FR                YT
         145   JQ            Mexico                               mx            MX                MX
         146                 Micronesia                                                           FM
         147   DQ            Moldavia                             pl            PL                MD
         148                 Monaco                               fr            FR                MC
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 96/143
         149                 Mongolia                                                             MN
         150                 Montserrat                                                           MS
         151   GP            Morocco                             ma             MA                MA
         152   HL            Mozambique                          pt             PT                MZ
         153   EJ            Myanmar                             mm             MM                MM
         154                 Nambia                                                               NA
         155                 Nauru                                                                NR
         156   EV            Nepal                                np            NP                NP
         157   BL            Netherlands                          nl            NL                NL
         158   BN            Netherlands KPN                      nl            NL                NL
         159                 Netherland Antilles                                                  AN
         160   KZ            New Caledonia                        fr            FR                NC
         161   KS            New Zealand                          nz            NZ                NZ
         162   JS            Nicaragua                            ln            LN                NI
         163   GK            Niger                                x1            NG                NE
         164   HW            Nigeria                              ng            NG                NG
         165                 Niue                                                                 NU
         166                 Norfolk Island                                                       NF
         167                 Northern Mariana                                                     MP
         168   CM            Norway                               no            NO                NO
         169   FV            Oman                                 om            OM                OM
         170   FB            Pakistan                             pk            PK                PK
         171                 Palau                                                                PW
         172                 PALESTINIAN TER, OCC                                                 PS
         173   JT            Panama                               ln            LN                PA
         174                 Papua New Guinea                                                     PG
         175   KA            Paraguay                             ar            AR                PY
         176   KL            Peru                                 pe            PE                PE
         177   EG            Philippines                          ph            PH                PH
         178                 Pitcairn                                                             PN
         179   BX            Poland                               pl            PL                PL
         180   BQ            Portugal                             pt            PT                PT
         181                 Puerto Rico                                                          PR
         182   FW            Qatar                                qa            QA                QA
         183   LB            Reunion                              fr            FR                RE
         184   BY            Romania                              ro            RO                RO
         185   CC            Russia                               ru            SU                RU
         186   HP            Rwanda                               ke            X1                RW
         187                 Saint Helena                                                         SH
         188                 Saint Kitts and Nevis                                                KN
         189                 Saint Lucia                                                          LC
         190   LH            Saint Martin (Guadeloupe)            fr            FR
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 97/143
         191 LC              Saint Pierre and Miquelon            fr            FR                PM
                             Saint Vincent and the
         192                                                                                      VC
                             Grenadines
         193                 Samoa                                                                WS
         194                 San Marino                                                           SM
         195                 Sao Tome and Principe                                                ST
         196   FK            Saudi Arabia                         sa            SA                SA
         197   HJ            Senegal                              sn            SN                SN
         198   CB            SERBIA AND MONTENEGRO                yu            YU                CS
         199   HY            Seychelles                           fr            FR                SC
         200                 Sierra Leone                                                         SL
         201   EQ            Singapore                            sg            SG                SG
         202   DS            Slovakia                             sl            SL                SK
         203   DY            Slovenia                             si            SI                SI
         204                 Solomon Islands                                                      SB
         205                 Somalia                                                              SO
         206   HZ            South Africa                         za            ZA                ZA
         207   EB            South Korea                          kr            KR                KR
         208                 South Georgia                                                        GS
         209   AX            Spain                                es            SP                ES
         210   EW            Sri Lanka                            lk            LK                LK
         211   FF            Sudan                                x1            X1                SD
         212                 Suriname                                                             SR
         213                 Svalbard and Jan Mayen                                               SJ
         214                 Swaziland                                                            SZ
         215   CQ            Sweden                               sv            SV                SE
         216   CS            Switzerland                          ch            CH                CH
         217   FX            Syrian Arab Republic                 sy            SY                SY
         218   EC            Taiwan                               tw            TW                TW
         219                 Tajikistan                           ru            SU                TJ
         220   HR            Tanzania                             ke            X1                TZ
         221   ER            Thailand                             th            TH                TH
         222                 Timore                                                               TL
         223   GS            Togo                                 ci            CI                TG
         224                 Tokelau                                                              TK
         225                 Tonga                                                                TO
         226                 Trinidad and Tobago                                                  TT
         227   GQ            Tunisia                              tn            TN                TN
         228   DC            Turkey                               tr            TR                TR
         229                 Turkmennistan                        ru            SU                TM
         230                 Turks and Caicos Islands                                             TC
         231                 TUVALU                                                               TV
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 98/143
         232   HN            Uganda                               ke            X1                UG
         233   DV            Ukraine                              ru            SU                UA
         234   FM            United Arab Emirates                 ae            AE                AE
         235   BS            United Kingdom                       uk            UK                GB
         236   JD            United States of America             us            US                US
         237                 United States Minor                                                  UM
         238   KC            Uruguay                              uy            UY                UY
         239   DR            Uzbekistan                           ru            SU                UZ
         240                 Vanuatu                                                              VU
         241                 Vatican                                                              VA
         242   KM            Venezuela                            ve            VE                VE
         243   ES            Viet Nam                             vn            VN                VN
         244                 VIRGIN ISLANDS, BRITISH                                              VG
         245                 VIRGIN ISLANDS, U.S.                                                 VI
         246   LE            Wallis and Futuna Islands            fr            FR                WF
         247                 Western Sahara                                                       EH
         248   FY            Yemen                                x1            X1                YE
         249                 Zaire                                                                CD
         250                 Zambia                               za            ZA                ZM
         251   HT            Zimbabwe                             zb            ZB                ZW
         252
         253                 export                               x1
         254                 export franco                        x2
         255                                                      x3
         256                                                      x4
         257                                                      x5
         258   CG            Telecom Austria                      au            AU                AT
18 REMARKS, RESTRICTIONS, TIPS …
Some old information was removed. Consult document from release 11.2 if needed.
18.1 ABC-F IP TRUNK GROUP
When creating the ABC-F IP trunk group, the Homogeneous network for direct RTP parameter must be
set to Yes if each node of sub-network located behind the ABC-F IP trunk group is in R9.0 or higher. If one of
the nodes of remote sub-network is in version less than R9.0, the parameter must be set to No.
If the sub-network, located behind the ABC-F IP trunk group, has a QSIG trunk group, the Homogeneous
network for direct RTP parameter must be set to No.
It is not possible to have both on a same node a ABC-F (IP or not) trunk group and a DPNSS trunk group.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 99/143
          The ongoing communications on an ABC-F IP trunk group are not maintained in case of Call Server switch-
          over. This limitation is removed as of Release 9.1.
          There is no encryption of the voice and signaling flows between two sub-networks linked by an ABC-F IP trunk
          group.
          This trunk group doesn't support the transparent fax/modem and cannot be distributed.
          Only one ABC-F IP trunk group between two OmniPCX Enterprises. No mixity ABC-F TDM / ABC-F IP between
          two sub-networks.
          18.2 APPLICATIONS
          18.2.1 AAS (Audio Station)
Warning    On secured sites (by ssh) the copy of the guides is not working anymore from OXE R12.0 Use a manual
           copy by using an ssh client program.
          18.2.2 External Voice Mail
          As of Release 10.0, the new parameter Subscription on registration in mgr-> Application ->External Voice Mail
          object is added.
          It must be set to False (Default value) when using external application such as UC R6, ACS, AVST, …
          In case of OXE set using Local Storage Mail box (on OpenTouch Solution), this parameter must be set to True
          to allow notification on the OXE set when he receives a new voice message. When OXE receives the "Register"
          from Local Storage Voice Mail, a "Subscribe" is sent for the user to receive notifications.
          18.2.3 LDAPs & ABC netw
          In case of heterogeneous network (if all the nodes in the network are not in M4):
          Do NOT activate of LDAPS or LDAP over TLS or eventually forbid the broadcast of “LDAP Phone Books” and do
          not perform any audit. This new management can be done once the whole network is in M4
          18.3 BOARDS
                 Case of GD/OMS new board or installation: it may take several reboots of the boards to load all the
                  voice guides into that board. Once they are all & completely loaded that process will not start again.
                  Check the incidents to know how many guides are loaded & if it the download is finished.
                  Example of messages thrown during the 1rst startup:
                  02/10/18 17:42:02 001010M|004/27/-/---|=4:0260=Beginning of downloading
                  /DHS3ext/vgadpcm/flash/std/vgadpcm.FR1
                  02/10/18 17:43:18 001010M|004/27/-/---|=5:0261=End of downloading
                  /DHS3ext/vgadpcm/flash/std/vgadpcm.FR1
                  02/10/18 17:43:19 001010M|004/27/-/---|=4:0260=Beginning of downloading
                  /DHS3ext/vgadpcm/flash/std/vgadpcm.IT1
                  02/10/18 17:44:59 001010M|004/27/-/---|=5:0261=End of downloading
                  /DHS3ext/vgadpcm/flash/std/vgadpcm.IT1
                 MIX board.
          OmniPCX Enterprise - Release 12.3.1
          Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
          Copyright © ALE International 2020                                                                  page 100/143
This board is not supported in a Rack 3U in central area.
     INTOF2 board.
The mixing of various generation boards is allowed in a same rack but:
        - the couplers in relation to the link must be of the same type
        - the type of INTOF must be of the same type if the link is doubled or tripled
the INTOFS and INTOF2S are not compatible between them. If changing from INTOFS to INTOF2S, you
should also change the INTOFS which is faced to this board. No consistency check is possible with the
management because each board is part of a different node. Nevertheless, an anomaly will be sent by the
INTOFS2 if the remote coupler is not the same.
     DPT1-2 board.
NPRAE and DPT1-2 boards cannot be used together on the same PCX.
18.4 CCS
R12.3 & R12.3.1 need CCS version 10.10.93.01 – otherwise CCS will not connect to OXE R12.3!!
18.5 CLIP
See previous document for more info about CLIP on Z32 feature.
18.6 Cloud Connect
Remote management capabilities via Cloud Connect (on FleetDashboard)
Fleetdashboard will offer the possibility to have an embedded terminal that can be used for maintenance or
management (“mgr”) usage. Feature to be released later.
18.7 COMMUNICATION SERVERS
18.7.1 Call Server CPU
       Direct connectivity of the Ethernet port of the CS-2/3 to a port of a switch is mandatory.
       Only auto-negotiation mode is supported on the CS-2 board => to be able to operate in Full-duplex,
        the port of the switch used for the connection must be configured in auto-negotiation. Otherwise, if
        the port of the switch is forced to full-duplex, the CS-2 will be unable to detect the full-duplex
        capability of the switch port and will operate in half-duplex. Rule: the port of the switch must be in
        auto-negotiation or forced to half-duplex.
       Protection against high broadcast traffic: available on CPU-CS (an incident is emitted) but it is not
        manageable.
       As of Release 9.0, CS-2 boards offer Ethernet redundancy with load balancing.
       Hard drive
                 In a standard installation, the following message is displayed. It states that any hard disk
                 larger than 80 GB will not be used to its real capacity.
                                   Alcatel-Lucent e-Mediate Linux installation
                                +-------------------+ Disk size +--------------------+
                                     |                                          |
                                     |                                          |
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 101/143
                              | Disk too big : use optimized up to 80000MB only. |
                                   |             +-----+         +----+              |
                                    |            | Yes |         | No |             |
                                   |             +-----+         +----+              |
                                      |                                           |
                                 +----------------------------------------------------+
                 The installation continues automatically after a timeout.
         Note: this is a case with PC Installer use (product no more maintained)
CS-3 precaution to extract the board ONLY once the POWER LED on the CPU is RED.
    -    power OFF the CPU by action on the button on the stiffener.
    -    Wait for the POWER LED to be RED
    -    Extract the board
CPU8    precaution to extract the board is to wait 10sec max. after cpu led goes to off.
    -    Shutdown -h now
    -    Wait for the message “Press any key to reboot” to be displayed on console
    -    set OFF the Switch ON/OFF located on the front of the board
    -    Wait for 10 seconds before extracting the board
In case the board is blocked (no boot, no display on v24 terminal) it is possible to reset the CMOS memory:
move the jumper near the battery to opposite position & move it back (1 sec. is enough to reset the cmos).
Time & date must be set again (tool “swinst”): this information is always lost in case of cmos reset.
Doing a cmos reset by short-circuiting the battery is safe.
Hard disk (CS/CPU7&8) recommendations: only the hard disks provided by Alcatel-Lucent are
compliant; manipulation of the hard disks (exchange of the hard disks etc.) is not recommended because of
the sensitivity of the hard disks; use preferably the second partition for software upgrades (limited:
from 12.0 to 12.0 & above).
18.7.2 G.A.S. (Generic Appliance Server)
To reboot the whole server, it is mandatory to stop FIRST the OXE (“shutdown -h now”) and then stop or
restart the server through Suse.
If the server is not ordered through ALE, check the compatibilities (cross comp. document, Suse & KVM
compatibilities in Suse web site).
A Raid server can be used if correct management is performed at bios level.
    !! soft RAID does not work! Only hardware RAID is supported
18.7.3 UPS
An UPS is strongly recommended to secure the system against abnormal stops because of power failure.
The UPS is used to make up for the short cuts of the power supply. If the UPS arrives at the end of the
battery, it tries to notify the Call Server / CPU to which its USB cable is connected. In the event of a long time
of power supply cut, it is necessary to stop the Call Server with the shutdown command.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 102/143
Note    GAS does not support feature of shutdown through USB connection from those UPS models. This is planned
        in a further release
       18.7.4 Blade Center & older CPUs
              Blade Servers are no more compatible as well as other CPUs mentioned in this document
              ACTIS behavior
                   o Blade: Actis will let people decide what kind of server will be used to migrate to R12.0:
                       Appliance Server or Virtualization.
                   o CPU5/6/7s1: Actis will propose a CPU7s2 or CPU8
                   o CS-1: Actis will propose CS-2 or CS-3 or Appliance Server/GAS depending of the traffic
       18.7.5 Passive Communication Server
       Updating PCS from version <12.0: disk reformatting is mandatory & needs to be considered before migration.
       Installation must be done locally or remotely by using S.O.T. tool (version 2.2 minimum)
       Passive Call Server as well as main or stand-by CPU must follow the rules of compatibility meaning that CS-1
       CPUs are not compatible
       If updating the software (patch or complete version) of a system equipped with PCS, it is necessary to update
       the PCS before updating the version of the Central Com Server (constraint related to database compatibility).
       If updating the software of PCS, it is necessary to check that this update does not start in the period of
       automatic re-synchronization of the database on the PCS (especially if the method used is the scheduled
       Remote Download) because this re-synchronization involves an automatic reboot of the PCS.
       When SIP set switches on PCS:
            It must register again as the Call Server registrar database is not replicated on the PCS.
            If it is in dynamic mode, a local DHCP server is required.
            In case of CS, the Main and Standby Call Server must not be located in the same rack.
            Do not use SLANX4 but an external switch (LANX16-1 or customer switch) in order to be able to
               unplug a Call Server without disturbing other elements.
       This feature is supported by the following IP equipment:
                        SIP sets
                        Alcatel series 8 sets
                        Alcatel-Lucent 8082 My IC Phone
                        GD
                        GA
                        INTIP
                        OXE-MS
                        IOIP
                        "IP Touch Security Module" : SSM, MSM
                        Attendant IP Softphone
                        IP CCAgent Softphone
                        MIPT sets
                        IP Dect
       OmniPCX Enterprise - Release 12.3.1
       Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
       Copyright © ALE International 2020                                                                  page 103/143
               The applications able to take into account 2 addresses of CPU are:
                        OmniTouch Contact Center : CCD/CCS/CCA/CCIVR
                        XML Web services
                        Application "XML IP Touch"
                        TSAPI
                        ACAPI
                        VoWLAN R2.0
       Features not available on AS and CS:
               V1 (4080 RE) - V2 (e-Reflexe IP Phone V2) sets. Only the IP sets of series 8 and SIP sets are able to
               take into account 2 addresses of CPU.
               Genesys applications (CCEmail, CCOutbound, CCWeb)
               RSI Synchro Server
               TAPI
       18.7.6 Appliance Servers/ G.A.S. & Bill Of Material (BOM)
       BOM of Appliance Servers is no more provided in this document. If needed, check with previous Release Note
       (OXE R12.1)
       Appliance Servers are no more sold in that form but are still supported in migration if compatible with the
       release. Replacement is done through the Generic Appliance Server (G.A.S.) based on existing platforms
       3BA27582CDAC (LENOVO X3250-M5 or M6) and 3BA27704CEAB (HP DL20 G9)
Note    Notice: in case of migration the ordered server is no more delivered with the software integrated.
        If a server is already in an installed OXE version it is possible to migrate to oxe R12.3 (e.g.: a G9 server in
        oxe R12.1 wants to migrate to oxe R12.3 This operation will be performed through the inactive partition)
        Notice: G.A.S. should be upgraded like the appliance servers where before. When a server is received from
        factory, administrators should look for the most advanced OXE version to put at the right level of software
       18.8 DECT
       Feature ip on xBS is released with following restrictions:
            If a base station was already installed on an oxe node & is transported to be installed on another node
               of the same network a factory reset has to be done (manual long push on a dedicated button). This
               reset factory can be done on any case where the update of the xBS takes too long time.
            Dect xBS when more than 253 xBS on the same location (contact Technical Support)
            Duration of the SW download for a handset (Step 1): due to the low bandwidth data channel used, it
               takes several hours for each handset to download a new SW version.
            Campus: in case a set is away from its location/cpu if that main cpu is switch (main to stand-by) &
               dect is in communication voice is cut.
            SUOTA is only available from OXE R12.3.1 (no backport in earlier releases)
            Dect2.4.4HB boards & External Handover cases: see chapter 15.2.4 for firmware compatibilities.
       OmniPCX Enterprise - Release 12.3.1
       Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
       Copyright © ALE International 2020                                                                   page 104/143
       Auto-registration: there are minimum versions of firmware to perform the Auto-registration
        8212: v0013b0002
        8232: v4483b0004
        8242: v6382b0003
        8262/62Ex : vx681b0006
       SUOTA: consult “TC2600 Ed 02: SUOTA for DECT Handsets in OXE 12.3”
Dect ip xBS: Web Based Management:
        Account “engineer” should only be used to view information. Parameters are pushed from the OXE
        and there is no need to do any management directly on the xBS itself.
        Modifying those parameters directly on the WBM is strongly NOT recommended
18.9 DIRECTORY
External LDAP Server:
LDAP overflow is available on all sets.
Alcatel-Lucent Premium Deskphones, myIC phone Standart & 40x8/40x9 sets as well as Reflexe/eReflexe have
an "Overflow" softkey.
During a phone book search with LDAP overflow setup, the PCX searches its local phone book the
corresponding entries to the search.
         - If the search in the phone book succeeds, only the sets having a "Overflow" softkey can use the
             softkey to complete their search in the external LDAP server.
         - If the search in the phone book fails, the search overflows towards external LDAP server whatever
             the type of set.
The search in the external phone book is a "Begin with" search (the similar entries are not displayed).
The result displays the directory number or if it misses the mobile number (both information are not
displayed). If no number is available, the entry is ignored even it corresponds to the search.
client_ldap was no more available in R8.0.
    - In Release 8.0.1, a new client_ldap tool is available. It performs an LDAP search on telnet access.
         You don't need any more to give LDAP parameters, such tool uses actual OmniPCX Enterprise
         configuration and requires only to specify the Entity Id.
        (611)xa006011> client_ldap
        Entity of set
        54
        Entity = 54
        0 => Exit
        1 => Search by name
        2 => Search by initial
        3 => Search by name and first name
        1
        Request Name ...
        paris
        Request 5 paris
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 105/143
               Result reply_count 3
               Result 0 PARIS STEPHANE 61234
               Result 1 PARIS DELPHINE 72123
               Result 2 PARIS LAURENT 72345
               (611)xa006011>
               Troubleshooting
               You can trace the overflow to external ldap server by phone book process
               For the UTF-8 phone book
               On OmniPCX Enterprise console launch:
               utf8_pbm_tuner output-tty=`tty`
               utf8_tuner trace-level=all
               For non UTF-8 phone book
               On OmniPCX Enterprise console launch:
               pbm_tuner output-tty=`tty`
               tuner trace-level=all
       Search in UTF-8 phone book.
       This feature is only available for Premium Deskphones, myIC phone Standart & 40x8/40x9.
Note    If the UTF-8 field is completed in user data with the same information as Latin name, the search of name in
        the directory, using "Call by name", will give a double result (Latin name + UTF-8 name).
              From R9.1 (I1.605.31), search in internal Phone Book (Call-by-name search) with several results for
               internal numbers and abbreviated numbers display first internal number before Abbreviated number in
               case of dual entries for a same Name.
       18.10 FSNE
       When SRTP is activated on SIP trunk, specific constraints apply to the whole network.
       There are only 2 configurations allowed:
          1) SRTP is allowed in local node
               In that case, all hybrid links in the subnetwork must be non-encrypted.
               SRTP offer answer mode is true on this node only.
           2) SRTP is allowed in all the network
               In that case, all hybrid links in the subnetwork must be encrypted.
               SRTP offer answer mode is true on all nodes.
               In case of several sub-networks, it applies to all.
               No TDM link can be used. No TDM trunk between 2 sub networks can be used.
                So be careful when coming from network encryption with SIP in clear mode to SIP trunk with
                 SRTP. Constraints are stronger.
       OmniPCX Enterprise - Release 12.3.1
       Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
       Copyright © ALE International 2020                                                                  page 106/143
          No support for 4645 Voicemail
          No IPv6 Support
          No support for SIPTLS implementation
          No compatibility with Thales installed server
          No support for GD, GD2 and IOIP3 boards
          No VPN support (Set movement via network is impossible)
          IPDSP with encryption support:
              -  not developed in Mutual Authentication mode
              -  in case of usage with Plantronics headset it is recommended to install the Plantronics software
                 (https://www.plantronics.com/us/en/support/downloads-apps/hub-desktop) to avoid audio issues.
          In Band DTMF is incompatible with SIPTLS-SRTP encryption. In Band should not be configured if SIPTLS-
          SRTP encryption is enabled.
          Command to print CTL on OXE:
          “openssl crl2pkcs7 -nocrl -certfile /etc/pki/oxe/truststore/trustchain.pem | openssl pkcs7 -print_certs -text -
          noout”
          Transform pem/crt -> p12:
          “openssl pkcs12 -export -nokeys -in xxx.pem -out xxx.p12”
          In case of mutual authentication, certificates of type client for GD3/INTIP3/OMS
          In case of mutual authentication, certificates of type client for the sets as well.
          18.11 IP CRYSTAL MEDIA GATEWAY
          In the
               document the name "INTIPA or B" concerns the INTIP board as well as the INTIP2 board.
               The GPA2 is supported in the IP Crystal Media Gateway.
               INTIP board cannot be used with embedded Ethernet (a CBC1 10/100 connector must be used).
               INTIPA board can be used with 100 Mbits. With a VH cabinet you have to use the Patch Panel
                10/100Mbits Reference 3BA 23244 AAAA 01.
               100 Mbits compliance with WM1 and VH cabinets for CPU6 Step2 (not compatible R12.0 & above) and
                CPU7 (S1/2).
Warning    As mentioned previously a CPU7 S1/2 is not allowed in a VH cabinet.
          All cabinets are or will be compatible with 10/100BaseT. The VH and WM1 cabinets compatible 10/100BaseT
          will be available soon with the following references:
                                  Designation                                                  Reference
          VH (10/100BaseT) Basic Rack 48V                                                    3BA 56191 AN
          VH (10/100BaseT) Basic Rack 48V - USA                                              3BA 56191 UN
          OmniPCX Enterprise - Release 12.3.1
          Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
          Copyright © ALE International 2020                                                                  page 107/143
       VH (10/100BaseT) Basic Rack 90W                                                    3BA 56193 AN
       VH (10/100BaseT) Basic Rack 90W - USA                                              3BA 56193 UN
       VH (10/100BaseT) Extension Rack 48V                                                3BA 56192 AN
       VH (10/100BaseT) Extension Rack 48V - USA                                          3BA 56192 UN
       VH (10/100BaseT) Extension Rack 90W                                                3BA 56194 AN
       VH (10/100BaseT) Extension Rack 90W - USA                                          3BA 56194 UN
       WM1 (10/100BaseT) Basic Packed 110/230V                                            3BA 27112 AN
       WM1 (10/100BaseT) Basic Packed 110/230V - USA                                      3BA 27112 UN
       WM1 (10/100BaseT) Basic Packed 48V                                                 3BA 27113 AN
       WM1 (10/100BaseT) Basic Packed 48V - USA                                           3BA 27113 UN
       WM1 Battery package (battery autonomy 1.2 Ah)                                      3BA 57106 AC
       WM1 Battery package (battery autonomy 1.2 Ah)- USA                                 3BA 57106 UB
Note    If the referenced cabinets above are not used, the CPU6 Step2 and CPU7 boards will work at 10 Mbits
        maximum.
       18.12 IP TOUCH SECURITY FEATURE
       The IP Touch Security feature works with a secured patch, delivered in complement of the generic version.
       To get this secured patch, a request must be made on Alcatel-Lucent Business Partner Website.
       This secured patch has the same name as the generic delivery to which it is referred preceded by the letter S
       (for Security).
       This secured patch contains only:
       Secured binaries for IP Touch series 8
       Secured GD binaries likely to encrypt the signaling directly
       Secured GD3 / GA3 / INTIP3 binaries likely to encrypt both voice and signaling directly
       Binaries for IP Touch Security Module.
               The installation of this secured patch is carried out in a second step after installation of the generic
               version and patch.
       In multi-SSM duplicated configuration:
       The 4645 must be on a dedicated CPU protected by a MSM
       The encryption of the OmniTouch UC server cannot be done by one of the two SSM but by the use of a MSM
       In multi-SSM spatial redundancy configuration (SSM in blocking mode), it is necessary to define a specific link
       between IP physical address of each Call Server and main IP address of the other Call Server.
       In multi-SSM traditional duplication configuration (only one main address):
       During module initialization if the Main address was defined on the plain and cipher port, in established mode
       the module considers the Main address on its plain port (in normal state, IP element cannot be at the same
       time on the plain port and cipher port)
       In a result of the preceding point, the modules must remain in passing mode
       Before moving a set of a secured system towards an unsecured system (moved within a ABC network or
       changed on another system), unsecured manually the set and remove it from IP network before it recover
       again the lanpbx.cfg protected file.
       OmniPCX Enterprise - Release 12.3.1
       Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
       Copyright © ALE International 2020                                                                  page 108/143
After each change of mode (secured / unsecured), Call Server must be restarted.
To customize GD3 / INTIP3B board with Soft-MSM feature (PSKmg), the version 1.2.01 of Security Center has
to be used. GA3 and INTIP3A boards don’t have to be customized and must be configured with Voice MSM
type instead of SoftMSM type (to be used only for GD3 and INTIP3B).
Only boards with SoftMSM type (ie GD3, INTIP3B) are taken into account by software lock 348.
Before activating Soft-MSM feature on a NGP board, it is mandatory for the board to perform an initial boot
without encryption (MG type selected in "Addresses to protect" MAO object).
18.13 MEDIA GATEWAY
18.13.1 GD/GA boards
       Direct connectivity of the Ethernet port of these boards to a port of a switch is mandatory.
       By default, dynamic IP addressing is active (DHCP) on a GD board.
       The GA board does not support DHCP feature.
       If the GD supports H323 links, a static IP address must be assigned to the GD.
       Due to the possibility of the GD to encrypt directly its signaling link, two versions of GD binaries are
        available from Release 9.0: one containing the encryption mechanisms and one without. As for the IP
        Touch sets since Release 6.2, the generic OmniPCX Enterprise versions provide the binaries without
        the encryption mechanisms, whereas the binaries with these mechanisms will be available in the
        corresponding secured patch.
       GD/GA binaries (secured or not) are systematically signed. This information is verified only on PBX in
        protect mode.
18.13.2 INTIPB board
In this document, the name "INTIPA or B" concerns the INTIP board as well the INTIP2 board
      Direct connectivity of the Ethernet port of the INTIPB board to a port of a switch is mandatory.
      The INTIPB board supports 10/100Mb/s and Half/Full Duplex mode.
      The mode Full-Duplex or Half-Duplex (default mode) of the INTIPB must be configured via the V24:
If the switch is in auto-negotiation, the switch will operate in the mode configured in the INTIPB.
If the switch is configured in Full-Duplex, the INTIPB must be configured in Full-Duplex too.
If the switch is configured in Half-Duplex, the INTIPB must be configured in Half-Duplex too.
      To configure the INTIPB in static IP addressing mode or Half/Full, you must use the cable 3BA 28112
         for INTIP board and the cable 3EH 75003 AAAA for the INTIP2 board.
      The INTIPB board must not be used for H323 links or IP Phones handling.
18.13.3 Remote connection towards GD/GA/INTIP boards
18.13.3.1 Release 9.0 before patch H1.301.38
For safety reasons, telnet access towards GD/GA/INTIP boards has been disabled. The remote access towards
INTIP boards remains available using the cpl_online command.
Regarding the GD and GA boards, a mechanism similar to that of IP Touch sets has been implemented.
Activation of telnet service for a specific GD using the ippstat command.
Remote access towards GD/GA using the telnet_al <GD/GA_board_address> command.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 109/143
Note    This command corresponds to telnet <GD/GA_address> -b <CS_real_address>, the b option allows
        to force the sender address of the request and in this case not use the main address.
       The telnet client of the board GD/GA, which has been suppressed in Release 9.0, was necessary in particular
       to access the maintenance commands relative to the H323 process (telnet from the GD on its H323 port
       (4560)). These commands are now available through the ccmonitor command of the GD.
       18.13.4 NGP boards (GD3/GA3/INTIP3)
       Find below the different hardware compatibility information related to the use of NGP boards.
       NGP boards don’t support the following topics:
       Non "Direct RTP mode in network"
       Proprietary H323 inter-nodes protocol (only H323 mode is supported)
       Proprietary fax mode between Media Gateway (only H323 mode is supported)
       Contrary to INTIP, the INTIP3 board doesn’t support transit function. So with NGP, whatever the board used,
       the direct RTP mode is the only mode to take into account.
       NGP binaries (secured or not) are systematically signed. This signature is verified in all cases by Call Server
       (mode protect or bypass).
       Resources provisioning on Common Hardware NGP boards:
                         Armada     Compressors       N-way conferences        Voice Guide     3-way conf       DTMF
                        daughter                                                 access                       receivers
                          board
       GD-3 mix                                      1x7, 2x7, 3x7, 4x7 or
                           No             15                                        16             24            30
                                                      1x15, 2x15 or 1x30
                           No             30                   0                    16             24            30
                                                     1x7, 2x7, 3x7, 4x7 or
                          Yes             45                                        16             24            30
                                                      1x15, 2x15 or 1x30
                          Yes            60                    0                    16             24            30
       GA-3 N-conf        No              0           4x7 or 2x15 or 1x30           16              3             0
       GA-3 mix           No             15          1x7, 2x7, 3x7 or 1x15          16              3             0
                          No             30                    0                    16              3             0
                          Yes            30         3x7, 4x7, 2x15 or 1x30           0              0             0
                          Yes            45            1x7, 2x7 or 2x15              0              0             0
       GA-3 VoIP          Yes            60                    0                     0              0             0
       GA-3 3-conf        No              0                    0                     0             21             0
       PowerMex           N/A            N/A                  N/A                    0             24            30
       The account root has to be used to enter the console of a NGP board. The account admin exists but doesn’t
       allow doing anything.
       To reload from scratch a binary in a GD3/GA3/INTIP3 board, just use PC Installer and perform a network boot
       of the board: it will automatically reformat its flash and then download the various binary files. The LOLA
       mode, used for GD/GD2 boards is no more necessary as the flash reformat is performed automatically. A
       reboot of the NGP board is mandatory after the flashing process.
       To enter the BIOS of a GD3, GA3 or INTIP3, as for a GD board, the sequence Ctrl-B Ctrl-I has to be done
       (rather quickly for NGP).
       OmniPCX Enterprise - Release 12.3.1
       Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14      TC2632en-ed.06
       Copyright © ALE International 2020                                                                     page 110/143
U-Boot 1.3.0-rc3 (Apr 15 2009 - 16:37:27) 3EH30350AAAI bootl100/000.008
Reset Status: Software Hard, External/Internal Soft, External/Internal Hard
CPU: e300c4, MPC8377, Rev: 21 at 399.999 MHz, CSB: 266 MHz
I2C: ready
DRAM:
DDR DIMM: data bus width is 64 bit without ECC
DDRC ECC mode: OFF
DDR RAM: 256 MB
FLASH: 2 MB <---------------- Press quickly Ctrl-B Ctrl-I immediately after this info
PCI: Bus Dev VenId DevId Class Int
00 17 1064 2102 0000 00
In: serial
Out: serial
Err: serial
Net: TSEC0, TSEC1
18.13.5 OMS (remote access & ESXi configuration rules)
Several modifications were done in relation to secure the access of the OMS. Refer to the precedent document
for more details on older versions. Remember that it is now the « admin » user that should be used to connect
on OMS (ssh -2 command).
Virtualization rules (extract from doc “OT suite –hosting – virtualization”)
… this solution is built with one or several OXE Media Services Base and optional access ports (up to 120 per
Base).
Hardware pre-requisites for OXE MS depends on the number of ports and coding/compression algorithm:
        •   One dedicated core processing (via “affinity rules”, from vShpere client management) per OXE MS
            requiring 100 MHz for the Base.
        •   Hyperthreading has to be disabled on the OXE MS Virtual Machine
        •   Processing per port:
            •    With G711 coding only: 5 MHz with a maximum of 120 ports per OXE MS Base
            •    When G729 compression is used: 25 MHz with a maximum of 90 ports per OXE MS Base
        •   Virtual Hard disk per OXE MS Base: 4 GB
Dedicated and reserved memory PER OXE MS Base: 512 MB of RAM … END of extract
18.14 SECURITY
Use the tool “securitystatustool” to check the security management of the oxe (xml output). See below the
different topics scanned by that tool (data not expanded)
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 111/143
18.15 SETS
18.15.1 8088 Noe/ Android
No desksharing in ABC network.
8088 noe/ Android sets: use the “bugreport” tool as described in Technical communications (TC2347en-Ed04 -
Technical Release Notes For 8088 R301 Smart Deskphone) in case of bug to report to technical report. Result
will be asked.
18.15.2 DECT
        In the case of common hardware, DECT can be installed on different Media Gateways, but these
         Media Gateways must be necessarily located on different sites due to the interferences this would
         generate, the Media Gateways being not synchronized from a DECT point of view. You should not
         have overlapping between base stations.
      Only frequency number 1, 2, 4, 8 are available for PWT (5 does not work); same as for Crystal
         hardware.
      DECT Campus.
The DECT Campus feature is not supported with Call Server or Appliance Server driving common hardware or
Crystal Media Gateway.
Due to a bad synchronization of INTOFS board, the DECT Campus is not operational. DECT(s) remain attached
to their preferential node. Thus, in limit of coverage, there is no handover towards the node of better
coverage. In this case, reset INTOFS boards of the PCX after restarting the PCX
      No cohabitation of DECT2 and DECT4 with DECT8.
      5 digit DECT dialing.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 112/143
This feature is only allowed for Mobile 100&200 Reflexes, Ascom DECT, 4074 HB in UA2 mode, GAP sets, TSC
DECT, 4073 (PWT).
     As of Release 8.0, XL configuration is only supported on Appliance Server and does not allow an
        operation of Campus DECT.
     As of Release 8.0, DECT is available for USA. PWT and DECT cannot operate on the same installation.
     INTIP3B board carries out a full DTM function for its own ACT. This means all DECT synchronizations
        are broadcasted over the whole remote crystal including sub-level. In such case, there is no more
        need to use an additional DECT synchro board in the shelf. It is forbidden in a remote ACT to perform
        this DTM function on both INTIP3B and DECT board. INTIP3B switchover preserves the DECT
        synchros.
Dect firmware update:
   -    Consult “Technical Communication TC2600 - SUOTA for DECT Handsets in OXE 12.3” to know how to
        upgrade the firmware on all dect sets (82xx series ONLY)
   -    It is always possible to do that update through a manual download by using a cradle.
18.15.3 IP DECT system (NEC)
Generalities:
 In case of incoherency mobiles management between OXE and DAP controller the DAP reboot:
   workaround is to use authentication between DAP and OXE (Will be fixed in a maintenance version)
 Audio clack in com in G729: workaround is to disable VAD (analysis on going for a fix with VAD)
 Call cut after 50s when DAP managing the handset is disconnected: when during a call the communication
   between the visiting DAP (handles DECT communication with handset) and the registration DAP (handles
   the communication with the SIP server) is lost for more than 50 seconds, both DAPs will clear the call.
4080 DECT IP Access Point:
 No Static IP address management (only in DHCP mode)
 No LLDP Poe negociation
 No AVA and no LLDP-MED VLAN ID acquisition
 No multi-PARI support
 No TFTP server redundancy
 No G723
 No telnet
 No ARP spoofing nor DoS protection
 NAT is not supported
 No RJ45 Cat 7 support
DAP Controller/Manager installer:
 No redundancy of the DAP Manager
 DAP manager and OmniVista 4760/8770 cannot be hosted on the same physical server
 DAP manager cannot be virtualized
ALU DECT IP offer:
 TDM-DECT (IBS or RBS) and IP-DECT APs cannot be mixed on the same OXE system
 MR100/200 handsets are not supported
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 113/143
   No end to end encryption (No encryption over the lan)
   ALU feature called “DECT over campus” is not supported
   Notification server integration enhancement on 400 DECT handsets is not supported (AAPP with newVoice
    notification server).
18.15.4 IP Phone V1 – V1S – V2 (e-Reflexe) – Alcatel series 8 & 9
Consult previous document version. Information has been removed.
18.15.5 MIPT 300 & 600 handsets
For more information, refer to the technical communications TC0940 Technical Release Note for VoWLAN
Release 3.0 offer and TC1195 Technical Release Note of VoWLAN 4.1 for OmniPCX Enterprise.
     MIPT handsets have same level of feature than an IP Touch set (call by name, tandem, Boss /
        secretary, notification messages, Hotel and Hospital sets, etc.).
     MIPT handsets are not supported in Contact Center, attendant, etc.
     MIPT handsets support codecs G711 and G729A.
     MIPT handsets supports the WEP, WPA and WPA2-PSK
     As of Release 8.0, VoWLAN offer operates around Alcatel-Lucent IP Touch 310&610TM (MIPT
        310&610) handsets, integrating the NOE protocol (New Office Environment) and compatible with or
        without Mobile IP Touch SVP Server (SVP Server). The mode without SVP server is only available on
        the OmniAccess WirelessLAN infrastructure. If there is a mixing of MIPT 300&600 and MIPT 310&610
        handsets, a SVP Server must be used.
18.15.6 NOE3G (premium ip phones)
Only NOE3GEE sets are compatible with ipv6.
18.15.7 NOE3G EE (Extended Edition)
Use the command “downstat i” to check who is not updated & rebooted.
Use the command “downstat i r HH:MM” to program a reboot of those sets.
Use the command “tftp_check -s -t [time]” to start the download (incident thrown: 391: “Update the binaries
of IP set by tftp server”).
Known restrictions, technical details, evolutions … Refer to technical communication: TC2308 Technical
Release Notes For 8028S, 8058S, 8068S, 8078S Premium Deskphones
18.15.8 OTC Android Smartphone
CROXE-3530 - OTC Android Smartphone // OS Android 7 Update issue
Since Android OS Nougat Update some ports historically used by the System are now in Conflict with OS
Nougat reserved ones.
Default port for signaling is 32512, this port is in the range of reserved port in Android 7 (32100 to 32599).
To allow android 7 devices, you must change the configuration of default port (IP-> TSC/IP Parameters ->
UDP port). Must also take this change is the firewall configuration
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 114/143
          18.15.9 NOE sets: new reboot cause
          Below are reset cause after 39. Detailed cause is still not updated in “incinfo”
            NOE_TO_NOE_SIP                          = 40
            NOE_SIP_TO_NOE                          = 41
            SIP_REG_TIMEOUT                         = 42
            SIP_REG_REFUSED                         = 43
            BT_DEVICE_RESET                         = 44
            ICTMODULE_STOP                          = 45
            RELOAD_NEW_FONT                         = 46
            BINARY_UPGRADE_COMPLETE                 = 47
            USER_REBOOT_REQUEST                     = 48
            LMMI_NEED_RESET_FLASH                   = 49
            VPN_INIT_FAILED                         = 50
            VPN_CONNECTION_LOSS                     = 51
            VPN_CONNECT_BAD_SUBNET                  = 52
            VPN_RECONNECT_IP_DIFFER                 = 53
            VIRTUAL_ADDON_CONFIG                    = 54
            DTLS_ENABLED                            = 55
            DTLS_DISABLED                           = 56
          18.15.10 SIP SETS
          all standard SIP sets must be declared with the SIP Extension type. Standard SIP sets are no longer
          supported with the former "SIP Device" mode (formerly called "External set"). Only items other than standard
          sets (Nokia sets in Dual mode, Alcatel 4135 conference module, fax, video, etc.) should remain with the
          former "SIP Device" mode.
          Set 8088 used for huddle room does NOT follow this rule and MUST be managed as "SIP Device" (simplified
          telephonic features).
          The “sip extension” mode (Native SIP Call Controller, also named SEPLOS - SIP End Point Level Of Service in
          some technical documents) allows to increase strongly the level of service on a SIP set, compared with the SIP
          standard (use of many OmniPCX Enterprise prefixes, etc.). Only the sets mentioned in the SEPLOS "white list"
          (refer to the technical documentation TC1108 Native SIP Call Controller: White List) will be supported in
          complete SEPLOS mode. This "white list" is likely to be regularly expanded further interoperability tests
          performed in the AAPP framework. The sets not listed in the "white list" continue to be supported with the
          basic level of service offered by the SIP standard (functioning equivalent to R8.0).
Warning    It is mandatory to declare Nokia sets, used in Dual mode with OXE, as well as 4135/8135S IP Conference
           Phones, with type "SIP device" (TC2556).
          Business SIP sets in "SIP Extension" are mandatory multiline and room sets monoline. These modes are those
          available by default and must not be modified for any reason.
          Refer to the Feature List for the list of telephonic features available on SIP sets.
          OmniPCX Enterprise - Release 12.3.1
          Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
          Copyright © ALE International 2020                                                                  page 115/143
18.16 SIP TLS FOR EXTERNAL GATEWAY
SIP TLS/SRTP protocols are supported to secure SIP Trunks configured on the OXE to a Carrier or Service
Provider network (Public SIP Trunking in ISDN mode). The TLS protocol protects SIP signaling and the SRTP
protocol protects voice flows.
Depending on Carrier/Service Provider capabilities, voice media can also be encrypted using SRTP. Each Public
SIP Trunk can be configured at OXE level with SIP TLS&RTP or SIP TLS&SRTP. The voice media can be end-
to-end encrypted (using SRTP) from the IP Touch set in the customer’s network up to the Carrier’s gateway.
Notice on system configurations:
        SSM boxes model and MSM boxes model are not compatible with the SIP TLS feature. These boxes
           must be replaced by new Server Security Modules SSM-RM and Media Security Modules MSM-RM in
           front of PCS.
        SIP TLS with SIP devices or SIP extensions is not supported.
        From R12.3.1: a system with an OXE and THALES based encryption solution & public SIP trunks: it
           is will be possible to benefit from TLS encryption technology for this SIP trunk (length of keys
           certificates of 4096 bits, TLS 1.2). Port 5061 in TLS 1.0 to change to 5261 in TLS 1.2
IPsec/SRTP and SIP TLS/SRTP protocols can be used simultaneously
18.17 VIRTUALIZATION
18.17.1 CONFIGURATION
Check the virtualization guide (Business Portal) & TC2431 (Virtualization: Configuration of OXE following
releases and ESXi infra version) for more details & provisioning level.
Consult document “https://businessportal2.alcatel-lucent.com/node/430986” for more about vm rules
configurations in ESXi vmware environment (doc available in the Business Portal).
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 116/143
          18.17.2 SUMMARY ON COMPONENTS NEEDED FOR INSTALLATION
                         tool used to tool used to     tool used to
                         install on     install on     install on
                         VMWARE         KVM            Hyper-V        info / how to install            misc
          OXE            S.O.T.         S.O.T.         S.O.T.         N.A.                             N.A.
                                                                      on vmware : web client
                                                                      needs to have a vCenter for      * OS on Suse 12 SP3
                                                                      Suse 12 selection                * all bootdvd 12.3.xxx.xxx
          OMS            S.O.T.         S.O.T.         S.O.T.         vmware 6.0 won't need that       are compatible
                                                       not released
                                                       yet            on vmware <5.5 : web client      * OS on Suse 12 SP3
                                                       (validation    needs to have a vCenter for      * all bootdvd 12.3.xxx.xxx
          OST                                          under          Suse 12 selection                are compatible
          (ost64+eegw)   S.O.T.         S.O.T.         progress)      vmware 6.0 does not need that    ! See "note" below
                                                                      Details in :
                                                                      "https://support.openrainbow.    see also Technical Comm.
                         WevRTCgw :                                   com/hc/en-                       #2462 chap.
          WebRTC         OVF/ISO                       Not in         us/articles/360001676490"        "Configuration for VoIP
          gateway        installation   Not in kvm     hyper-V                                         feature"
                                                                                                       *file "vmFlex-2.1.100.019"
                                                                                                       for CentOS 7 if ESXi 5.5 or
                                                                                                       more - same version
                                                                                                       number for kvm
                         vmware         kvm                                                            "vmFlex-Centos5-
                         installation   installation   Cloud                                           2.1.100.019" if ESXi <5.5
          FLEX Server    method         method         Solution only ovf deployement
                                                                                                       * the "disk imager" tool is
                                                                                                       not present in
                                                                                                       ALE Portal.
          Raspberry                                                   Win32 Disk Imager                *OS "ipdongle-firm-
          (PI3+ not                                    Cloud          (on "Sourceforge") to write on   1.0.000.000.img" is
          compatible)    NA             NA             Solution only SD card                           present on the Portal
Warning    Do not use Flex version 2.1.100.021 if you are using remote dongle on ip. It is not compatible
 Note      Eegw & OST64 are now gathered into a single virtual machine called OST. They cannot operate both at the
           same time in 1 single vm. Selection of either OMS or OST64 is done during installation by S.O.T.
          OmniPCX Enterprise - Release 12.3.1
          Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14                      TC2632en-ed.06
          Copyright © ALE International 2020                                                                                     page 117/143
18.17.3 RESTRICTIONS
GAS:
         soft RAID does not work! Only hardware RAID is supported
Other:
         Known as unsupported virtualization systems at the moment:
            o XEN (implies also Amazon)
18.17.4 Virtualized attendants
CROXE-5216: at CPU switching all com are lost and 4059 is unplugged.
This issue also occurs with physical PC and is not linked to virtualization. If there is no other type of attendant
(meaning all attendants are virtual) in the group public external call cannot be recovered.
18.18 VOIP
      The echo delay can no more be managed. It is set automatically according to the hardware used:
GIP6-GIP6A-MCV8-MCV24 board: the echo delay is limited to 32 ms.
GIP4-1/GIP4-4/MADA-1/MADA-3/Armada board: the echo delay is limited to 128 ms.
      Direct RTP H323.
The management of H323 direct RTP on OmniPCX Enterprise must be carefully enabled since all H323
terminals of the installation must be able to reroute the H245 RTP flow called "Empty Terminal Capability Set"
or "Voice Path Replacement".
No direct RTP between SIP set and a H323 terminal.
No direct RTP between H323 terminals with different compression algorithms (for instance case of H323
terminal in G723 or G729 calling a 4645 in G711)
      Direct RTP in network.
It is used with IP devices (IP Phones, Alcatel 4980 IP Telephony, GDx, GAx, 4645 voice mail, INTIPx, H323
equipment and H323 Gateways); it allows to establish a direct RTP communication between the 2 IP-devices
over the network in order to optimize the number of compressions/decompressions.
The DPNSS prefix for path replacement must be systematically managed.
The configuration must be homogeneous in the whole network; reboot of the system is mandatory after
activation of this feature.
Direct RTP in network is available with H323 terminals or H323 Gateway if all nodes are in Release 7.0 or
higher.
NGP boards support only the "Direct RTP in network" mode.
In Release 9.1, the Direct RTP mode parameter in "IP / IP Parameters" has been suppressed and the Direct
RTP mode in network activated in all cases: the non Direct RTP mode in network is no more possible. This rule
applies for both new systems and systems upgraded from older releases to release 9.1. The other nodes of
the ABC-F network must be managed accordingly. All the Alcatel-Lucent devices used must support this mode.
      Multi-node transit without compression/decompression like in OmniPCX 4400: this optimization is not
         implemented in OmniPCX Enterprise; in place, direct RTP in network is provided.
      It is not possible to create several IP trunk groups for a GDx/GAx/INTIPx board => use the VPN Call
         Limitation feature to limit the number of calls per direction.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 118/143
        For a GDx/GAx/INTIPx, the number of trunks in a trunk group must not be managed. You must retain
         the default configuration (30 trunks created). The limitation of compressors will be carried out by
         managing the VPN TS % in the trunk group or by the "VPN Call Limitation" feature.
      From R5.0 Lx, QoS profile control on ABC-F VoIP links is no longer available (with/out direct RTP
         switching in network).
      The VoIPstat command is no longer usable.
      Mix of communication with Fax and Voice in a same room: during the voice communication, the DSP
         might change to Fax mode; the only workaround is to reduce the volume of the Fax.
      As of Release 9.1, the boolean H323 signaling for inter-node links has been removed: only the
         H323 mode is possible. The other nodes of the ABC-F network must be managed accordingly. NGP
         boards only support this mode.
      When creating or modifying the IP trunk group on a GD, the Media Gateway will reset in order to take
         into account the changes.
      UDP port range: UDP base port manageable by a system parameter and taken into account by all IP
         equipments (Call Server, INTIP, GD, GA, IP Phone, etc.) except Fast IP Enabler.
CAUTION
This parameter is common for all the installation and is managed only under
IP/IP Phones Parameters/UDP Port
      QoS Tickets.
QoS tickets are provided by GD/GA/INTIP boards, IP Phone V2, IP Touch (in NOE mode), My Phone and 4645
voice mail.
      Fax over IP.
The rate is limited to 9600 bit/s in Fax Relay mode with common hardware and Crystal Hardware.
The rate remains at 9600 bit/s for the inter Media-Gateway T38 fax mode, introduced in R9.0.
Fax T38 interworking with OmniAccess 512 (VSA Interface) is not available.
Fax V34 is supported.
From Release 7.0, the Analog type parameter used to create an analog equipment of "Fax" or "Modem" type
in order to initialize the connection in transparent mode from the start of the communication, concern only the
modem:
Users / Analog type + No specific management or Fax
If the equipment is a fax: Switch-over to transparency after detection of 2100 Hz by DSP.
If the equipment is a modem: Switch-over to transparency after detection of 2100 Hz par le DSP,
If there is no carrier, no switch-over to transparency.
If the equipment is a set: No switch-over to transparency except if the DSP detects the 2100 Hz.
If Fax behind GD or INTIP are used, verify and manage if necessary value 7 in "V21 Jitter Buffer Length"
under "IP/Fax parameters": all GDs and INTIP must be rebooted to validate this value
When the Inter-Media Gateway T38 fax, introduced in Release 9.0, is used it must be activated on the various
nodes connected by VoIP logical link. A manual reset of GD/INTIP boards is imperative to take into account
the new mode. This mode has also been ported in Release 8.0.1 since patch G1.503.35. NGP boards only
support T38 fax mode between Media Gateways.
On a secured system with Thales devices (IP Touch Security) and using the inter Media-Gateway T38 fax
mode, the Local T38 port number parameter must be set to RTP port Number + 0.
      Audiocodes MP-102.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 119/143
Interworking with MP-102 boxes is supported but only for fax transmissions (analog sets are not supported);
refer to the technical communication TC0336 Setting the T38 fax over IP application (with MP-102 version
4.0).
No accounting for fax calls.
     Audiocodes MP-112.
T38-SIP: From R7.1, the default value of the Minimal authentication method parameter is set to the
DIGEST (with a password).
T38 Fax over SIP operation is supported with the MP-112 equipment. The transfer in TCP mode is not allowed,
the UDP one must be used.
     Audiocodes MP-118
An analog set (respectively a fax) plugged on a MP-118 must correspond to a SIP set with type "SIP
extension" (respectively "SIP Device" / "External set") on CS side.
     IP Services / Port numbers.
The port numbers used are listed in the System Documentation.
CAUTION
The System documentation is also applicable for Releases 5.0 Lx and higher.
For VoIP flows, the range of UDP ports used can be customized in the range 0 to 65535; supported by all IP
equipment like GD, GA, e-Reflexes range (IP-Phone V2) etc. except Fast IP Enabler (TSC-IP V1S).
     Internal DHCP Server
Verify that the range of the IP addresses assigned is sufficient for the number of clients. If the number is
lower than the numbers of clients, it would duplicate IP addresses with Windows or MAC clients for example,
the server is not protected against the reactivation of IP address by these clients.
     Internal DHCP server is restricted to 5 000 IP Touch.
     G729 40 ms.
CAUTION
The lengthening of the sending framing over IP involves two consequences on the voice:
   1. An increase of the time from beginning to end.
   2. Any loss of package means that larger quantity of information is lost, involving a faster degradation of
        the voice.
     Jitter buffer.
Up to Release 9.0, the jitter buffer was managed by default in static mode with a buffer depth of 100 ms.
From Release 9.1, the default mode is changed with the use of the dynamic mode together with a buffer
depth of 300 ms. These new settings will help to avoid any packets accumulation on one side after a jitter
burst. They will also allow storing more packets and then accept a more important jitter.
18.19 MISCELLANEOUS
       Important: It is prohibited to install any other NAOS (RPM packages or pure binary) than those
        provided by ALE OXE
       Feature "Ensure database consistency" (introduced in R9.1)
        This feature is intended for cases where MAO modifications are done (mgr “like” management or user
        set modification) while the Stand-By is temporarily not present.
        The Double main Call Servers case is specific: MAO messages may be stored in the buffer of both Call
        Servers. When the duplication link is back operational, if there are stored messages in the Call Server
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 120/143
        which reboots as Stand-By (independently of the fact messages may have been stored or not in the
        Call Server which stays Main), then they are lost (on both Call Servers) and an incident 439 is
        displayed to recommend a manual synchronization (mastercopy). If messages have been stored only
        in the Call Server which stays Main, then they will be sent to the Stand-By after its reboot.
        Currently the MAO storage has two limitations: the buffer can store only 255 messages and the
        storing process cannot last more than two hours. From the patch I1.605.14.e, MAO messages are
        stored directly in RAM, removing the buffer limitation.
       In case of a V24-IP Moxa box, the time to recover the connection with the system after a Call Server
        switch-over is about 10 to 20 seconds.
       “mao for rebuild” backup file cannot be used from a file coming from a previous release (CROXE-
        2141). Issue will be seen from any release to M1 & upper. But not from M1 to later releases. This is a
        definitive restriction. Error is “segmentation fault” while restoring mao-dat
        Root Cause:
        To rebuild the database restored from "mao-dat" backup, binaries having same MAO version needs to
        be used.
        To overcome this "mao-dat" backup contains two files "/tmpd/fichges" and "/tmpd/checkinitrem" from
        the node where the backup is taken.
        Only this fichges binary should be used to rebuild that particular database, if the source and
        destination MAO versions are different.
        This will not cause any issues for kernel 2.4 to 2.4 BckRestore of "mao-dat" file.
        For 2.6 Linux, the older fichges binary is no longer compatible and causes a segmentation fault.
       Since Android OS Nougat update, some ports historically used by the system are now in conflict with
        OS Nougat reserved ones. Default port for signaling is 32512, this port is in the range of reserved
        ports in Android 7 (32100 to 32599).
        To allow android 7 devices, you must change the configuration of default port (IP-> TSC/IP
        Parameters -> UDP port).
        You must also take this change in the firewall configuration.
     Migration from crystal cpu to appliance/vm: if the migration of rack 0 is not done, check the presence
        of the file “AS.dat” under “/usr3/mao”. Delete it if you want to migrate to appliance/vm.
     Z sets ringing.
Maximum number of simultaneous ringing sets in a Rack 1U: 6.
Maximum number of simultaneous ringing sets Rack 3U: 20.
     In the event where you should use a T1 access and an E1 access on the same system, the two boards
        must be on different Media Gateway.
     MIPT.
No music played during a music on hold.
     Customized ringing melody.
The customized ringing file is limited to 16 melodies.
     T0 interface on Media Gateway.
T0 "network mode" is only supported with the BRA board. Refer to the technical communication TC0495 Using
the network mode on T0 accesses of BRA boards on Media Gateway.
     Number of mini-messages.
Maximum number of mini-messages is limited to:
        32 000 on Appliance Server
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 121/143
        10 000 on CPU7
        1000 on other CPUs
     4645 voice mail embedded on Call Server or Appliance Server.
The number of simultaneous accesses is limited to 16 for a 4645 on a dedicated Call Server (CS)
or embedded on an Appliance Server (AS).
The voice quality might be impacted by the double compression/decompression on the network when using a
poor IP domain (with G723/G729 codec) between the node of the voice mail and another node of the
network; even if the 4645 operates in G711, the 4645 will record a G723/G729 compressed/decompressed
speech; and again, at the restitution one G723/G729 compression/decompression will take place.
The attendant set has not access to the voice mail for consultation of the messages of a voice mailbox.
Rerouting of Fax is not supported.
The 4645 supports only DTMF sent in the signaling.
     Voice Guides.
GD/GA board supports maximum 4 languages for voice guides (including music on hold).
As of Release 8.0, GD/GA allows the playing of 40 min music on hold.
The USA voice guides are the default A4645voice guides.
     DSP resources per GPA.
The maximum number of DSP resources per GPA-GD is fixed as following (not extensible):
        DTMF Generation: 16.
        R2 detection + DTMF Q23/Q23X Detection + Tone (single and dual) Detection:
                payload of 5 % for R2:
                 maximum 20 detections for R2 when no Tone Detection,
                payload of 4 % for Q23/Q23X:
                 maximum 25 Q23/Q23X detections when no Tone Detection,
                payload of 3 % for Tone Detection:
                 maximum 30 Tone Detections when no Q23/Q23X detection.
        Voice Guides Play: 16.
        Addition (3-Party conferencing, discrete listening, etc.): 3.
The maximum number of DSP resources per GPA-MEX is fixed as following (not extensible):
        DTMF Generation: 16.
        R2 Detection + DTMF Q23/Q23X Detection + Tone (single and dual) Detection:
                payload of 7 % for R2:
                 maximum 14 detections for R2 when no Tone Detection,
                payload of 6 % for Q23/Q23X:
                 maximum 16 Q23/Q23X detections when no Tone Detection,
                payload of 4 % for Tone Detection:
                 maximum 25 Tone Detections when no Q23/Q23X detection.
        Addition (3-Party conferencing, discrete listening, etc.): 3.
The maximum number of DSP resources per GPA-GA is fixed as following (not extensible):
        Addition (3-Party conferencing, discrete listening, etc.): 3.
        Voice Guides Play: 16.
Mutual aid between Media Gateways regarding DSP resources is not provided (excepted for Voice Guide Play).
     Call Center and CSTA.
SOSM (Russia) is only available with 4400 hardware. An evolution of the box for Common Hardware is being
developed.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 122/143
EAU (United Arabian Emirates) is available.
     A-Law/-Law.
The A-Law / –Law configuration is valid for the whole system.
DPT1-2 board does not allow any more the A-Law / µ-Law conversion.
     PSTN synchronization.
In case of common hardware, the PSTN access must be in the main rack (not in extension racks).
In case of common hardware or IP crystal Media Gateway, the synchronization is local to the Media-Gateway
=> synchronization by domain must be configured (Synchro Number 200 to 254).
ACT 99 can't be synchronizing.
     eRMA.
The connection is lost in case of Call Server switch-over.
The connection won’t work if the Call Server Application is not running.
Only one simultaneous connection is possible.
eRMA connection works only in case of switching network connection on the GDx (does not in case of access
work through an ABC-F link).
eRMA feature is not available if the concerned Media Gateway encrypts directly the signaling (MGsec).
     Back-up signaling.
The time to recover the telephonic functions in case of back-up link activation is about 3 to 6 minutes
depending on the Media Gateway configuration and the type of signaling link used for the back-up.
The number of digits expected when receiving the back-up call must be managed; see the Technical
Documentation.
The boards used for the establishment of the back-up link must be in the main rack.
In case of Crystal Server, it is mandatory to have a Media Gateway near the main zone to have the backup
feature.
In case an APA link is used for back-up signaling, this APA link will be dedicated for the back-up signaling.
DASS2 or DPNSS links are not supported as back-up links.
No IP Phone in dynamic address.
No 4049 nor 4059 attendant station behind a Media Gateway with potential back-up link.
Connection of Hybrid link/H323 links behind a Media Gateway with potential back-up link is
possible.
The following features are not accessible/provided when the back-up link is active:
         Feed-back tone to the sets when dialing (except for IP-Phone V2).
         Access to voice mail 4635H or 4645.
         Call Center.
         4980 PC MM won’t work because the OTS server will not be accessible.
         Only local calls between the sets attached to the Media Gateway (including the IP-Phones attached to
         the Media Gateway) or external calls through the local PSTN connections are possible.
     Remote Extension.
Doesn't work with NDDI, APA, DASS2 and DPNSS.
In VoIP network with the algorithm G723/G729, the public access has to be in the same node that the remote
extension otherwise there will be DTMF detection problem. It works correctly with the G711 algorithm.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 123/143
19 TECHNICAL SUPPORT
Technical support will be provided to certified ACSE or ACFE engineers. The engineer must provide the valid
SMS/SES or SPS contract id (Support processes available on the Business Portal under the heading Customer
Support > Technical Support > Support processes).
Before contacting Alcatel's Business Partner Support Center (ABPSC), make sure that you have consulted:
        The Troubleshooting Guides (Diagnostics support guides) where they exist and perform the actions
           suggested for your system problem (available on the Business Portal under the heading Customer
           Support > Technical Support > Technical Documentation Library.
        The Technical Knowledge Center tool to perform a search, get a result, print the article or send it
           by email. This is the Alcatel-Lucent Enterprise Customer Care knowledge tool for Alcatel-Lucent
           Communications and Network solutions (available on the Business Portal under the heading
           Customer Support > Technical Support > Technical Knowledge Center ): Technical Knowledge
           Center
20 INTEROPERABILITY with Third-Party applications
In case of interoperability with Third-Party applications, it is highly recommended to verify the interoperability
either by contacting the Third-Party supplier or by checking the existence of a valid “InterWorking Report” on
the Business Portal.
Technical support will be provided only in case of a valid InterWorking Report and in the scope of the features
which have been certified. That scope is defined by the InterWorking report via the tests cases which have
been performed, the conditions and the perimeter of the testing as well as the observed limitations. All this
being documented in the IWR. The certification does not verify the functional achievement of the AAPP
member’s application as well as it does not cover load capacity checks, race conditions and generally speaking
any real customer's site conditions.
Any possible issue will require first to be addressed and analyzed by the AAPP member before being escalated
to ALE.
For any request outside the scope of this IWR, ALE offers the “On Demand Diagnostic” service where
assistance will be provided against payment.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14    TC2632en-ed.06
Copyright © ALE International 2020                                                                   page 124/143
21 README/ LIST OF FIXES
The list of fixes can be found in the delivery of the static & dynamic patches:
<dhs3mgr>\<PATCH NAME>readme (text file)
It also shows the name & versions of the components being modified from the previous patch.
The anomaly reports that are fixed have the tags “RA CROXES” or “RA CROXE” followed by the internal ALE
reference & a short description of the reporter.
New components have the tag “New”
21.1 M4.501.14 R12.3.1 MD4
List of all fixes
 ISSUE KEY            MAIN CR      PRIORITY      HOW FOUND                                     SUMMARY
                                                                      AFE crash after change the date of edition of Abandonned call
CROXE-16442         CROXE-16442    Major      endUser_customerSite
                                                                      report
CROXES-23094        CROXES-23094   Minor      endUser_customerSite Issue with search by name from AD on OXE and IPTouch sets
                                                                      Problem with hunting group users after modification on the
CROXE-17288         CROXE-17288    Major      endUser_customerSite
                                                                      group
CROXE-15071         CROXE-15071    Major      endUser_customerSite Wrong letters on CCD agent display when type 8028S
CROXE-16178         CROXE-16178    Major      endUser_customerSite Spontaneous restart of SIP motor with the Backtrace
                                                                   //1893_LSY//Call log in tandem configuration - Unanswered call
CROXE-15525         CROXE-15525    Major      endUser_customerSite on the desk phone when call on tandem (DECT or REX) has
                                                                   been accepted
CROXE-16271         CROXE-16271    Minor      endUser_customerSite RSI : Agent transfert issue on outbound call
CROXE-16540         CROXE-16540    Minor      endUser_customerSite Bad 8058s display when CTI is used to drive a conference
CROXES-9116         CROXES-9116    Minor      endUser_acceptance      "Allow" header not taken in account for Session Refresh
                                                                      # missing behind number causes 10 s delay when calling
CROXES-24303        CROXES-24303   Minor      endUser_customerSite
                                                                      (related to RB)
CROXES-23908        CROXES-23908   Major      validation_funcManual   OXE/M4 : Headphone icon is not displayed in attendant
CROXES-24709        CROXES-24709   Major      validation_funcManual   OXE/M4 : Backtrace occurs while doing audit
                                                                      OXE/M4 : Backtrace occurs while doing audit in Pre-Production
CROXES-24595        CROXES-24595   Major      validation_funcManual
                                                                      #2
                                                                      //1893F_LSY_RR// Demande analyse crash VM-OXE depuis
CROXES-24480        CROXES-24480   Major      endUser_customerSite
                                                                      migration R12.3.1
CROXES-24067        CROXES-24067   Major      endUser_customerSite Phones take too long to connect when PCS is running
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14          TC2632en-ed.06
Copyright © ALE International 2020                                                                         page 125/143
                                                                       Text message aborts with 'go on hook' when target calls the
CROXE-15319     CROXE-15319     Minor         endUser_customerSite
                                                                       writer of the message
CROXES-24321    CROXES-24321    Major         endUser_customerSite [Related] : Atrium#00455861 // Cannot link user to PBX
CROXES-23082    CROXES-23082    Major         endUser_customerSite "LIS server" incidents keep on showing//00418890//
                                                                       Wrong tones on digital sets connected on INTIP Shelf, when
CROXES-24458    CROXES-24458    Minor         endUser_customerSite
                                                                       doing a fresh install of OXE from SOT
CROXES-24747    CROXES-24747    Major         None                     Removal of CROXES-24214 and CROXES-24523
                                                                       //1893F_LSY_RR//Backtrace générée triple exception sur
CROXES-23446    CROXES-23446    Minor         endUser_customerSite
                                                                       équipement
CROXE-16793     CROXE-16793     Major         endUser_customerSite Tandem number (GSM number) displayed on S0 terminal
List of all Reports
 ISSUE KEY        MAIN CR      PRIORITY         HOW FOUND                                       SUMMARY
                                                                     [Report] : Lock SP 328 issue when restore new OPS files on
CROXES-24445    CROXES-18258   Major        endUser_customerSite
                                                                     Customer Site with duplication
CROXES-24246    CROXES-23453   Major        endUser_customerSite [Report] : License control for G729.
CROXE-17471     CROXE-17086    Major        endUser_customerSite [Report] : RSI : Enquiry call to withdrawn agent not possible
CROXES-24237    CROXES-23143   Major        endUser_customerSite [Report] : Impossible to transfer external call to a statistical pilot.
CROXE-17080     CROXE-14244    Major        endUser_customerSite [Report] : Ecart de statistiques
                                            endUser_prebetaSyste [Report] : Easy install of OXE feature : add control of /usr4 disk
CROXE-17345     CROXE-17097    Major
                                            m                    space + iso remove
CROXES-24227    CROXES-23374   Major        endUser_customerSite [Report] : DTMF issue when DECT with XBS used
                                                                     [Report] : mtracer with -u stop working when IPDSP start with
CROXES-24226    CROXES-23270   Major        endUser_customerSite
                                                                     incidents 1603 / 1607 linked to AOM
CROXE-17064     CROXE-14727    Major        validation_funcManual    [Report] : mtracer causes segmentation fault
CROXE-17082     CROXE-14869    Major        endUser_customerSite [Report] : Call is hang up when reach a 4645 in case of OMS uses
                                                                     [Report] : REINVITE including PAI fail (OXE replies 502 after 15s)
CROXES-24560    CROXES-24357   Minor        endUser_customerSite
                                                                     - Same REINVITE with no PAI succeed (OXE replies 200ok)
                                                                 [Report] : CAC blocked for SIP ISDN outgoing call with
CROXES-24225    CROXES-22167   Major        endUser_customerSite RE_INVITE for keepalive and enquiry call // 00378381
                                                                 //m3.402.24.a
                                                                     [Report] : [Related] : loop of forward in case of multidevice
CROXES-24586    CROXES-24053   Minor        endUser_customerSite
                                                                     causing several OXE crash
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14            TC2632en-ed.06
Copyright © ALE International 2020                                                                           page 126/143
                                                                    [Report] : "%20" in PAI when SIP extension uses Speed dial
CROXE-17070     CROXE-13609    Major        endUser_customerSite
                                                                    number created with Directory Name and First name .
CROXE-17303     CROXE-16832    Major        validation_funcManual   [Report] : M5 : HyperV2019 -sysstat log not started in OXE
                                                                    [Report] : Forward on no reply to a user on a distant node does
CROXES-24241    CROXES-23206   Major        endUser_customerSite
                                                                    not work
                                                                    [Report] : OXE/M3 :Back trace observed when a multi-line set is
CROXES-24675    CROXES-24661   Major        validation_funcManual
                                                                    forwarded to analog(Virtual) set in pre-production nodes
                                                                    [Report] : No voice connection when call from SIP ext.GW to CCD
CROXE-17254     CROXE-15551    Major        endUser_customerSite
                                                                    Agent.
                                                                    [Report] : //1893_PROSERV_ESC// OXR / Recording of call
CROXE-17067     CROXE-14774    Major        endUser_customerSite
                                                                    transferred appears with wrong remote number
CROXES-24240    CROXES-22465   Major        endUser_customerSite [Report] : Root cause analysis for the CPU reboot.//00401140
CROXES-24243    CROXES-22665   Major        endUser_customerSite [Report] : Random tranfer in DTMF mode from VAA server
                                                                    [Report] : M5 - CSTA make call with attached correlator data
CROXE-17235     CROXE-15805    Major        software
                                                                    leads to a crash of the OXE
CROXES-24554    CROXES-24118   Major        endUser_customerSite [Report] : ISDN ARS problem doesn’t take the second route
                                                                 [Report] : Impossible to perform Immediate Forward on target
CROXE-17388     CROXE-17077    Minor        endUser_customerSite DSU OOS/Logged-Off with previous customized Immediate
                                                                 Forward.
                                                                    [Report] : Backtrace on Standby CPU involving REX eqt while
CROXE-17074     CROXE-15499    Major        endUser_customerSite
                                                                    VoIP Rainbow Call on Mobile App is engaged.
CROXE-17066     CROXE-15378    Major        endUser_customerSite [Report] : DID number not send in case of forward on no answer
CROXE-17072     CROXE-13397    Major        endUser_customerSite [Report] : RSI : Call was not successfully transferred
                                            validation_nonRegress [Report] : M5-NRT: M5.204.3 Patch up-gradation failed in
CROXE-17528     CROXE-17305    Major
                                            ion                   inactive partition
                                                                    [Report] : Agent DECT Call by name doesn't work after OXE
CROXE-17075     CROXE-14857    Major        endUser_customerSite
                                                                    reboot if the agent was logon
                                                                    [Report] : Bad "to" content when abrev. number before CCD
CROXE-17079     CROXE-14585    Major        endUser_customerSite
                                                                    pilot:"to" is abreviated number.
                                                                    [Report] : SIPTLS M3/LDI : While Attendant involved in intrusion
CROXES-24239    CROXES-21490   Major        validation_funcManual
                                                                    call ,Voice path is not present.
                                                                    [Report] : [Related] : AVASAD / Open2Gateway lot of OXE
CROXE-17537     CROXE-17170    Major        endUser_customerSite
                                                                    incident 2676
                                                                    [Report] : Following migration to R12.2 and a bascul, DECT are
CROXES-24556    CROXES-23869   Major        endUser_customerSite
                                                                    froze -older Case 00409603 -
                                                                    [Report] : [Feature] Update linux kernel to 2.6.32-754.24.2 +
CROXE-16677     CROXE-15621    Major        review
                                                                    new openSSH for security vulnerabilities for M5 MD1
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14          TC2632en-ed.06
Copyright © ALE International 2020                                                                         page 127/143
                                                                      [Report] : Null pointer may be dereferenced // KW ID 58243//
CROXES-24540        CROXES-24483   Major      software_analysisTool
                                                                      CCx
                                                                      [Report] : //1893F_LSY_RR//Musique non diffusée sur trunk sip
CROXE-17071         CROXE-15582    Major      endUser_customerSite
                                                                      via csta genesys
                                                                      [Report] : Call cancelled in case of reception of 183 from SIP to
CROXES-24242        CROXES-23068   Major      endUser_customerSite
                                                                      H323 trunk to remote OXE.
                                                                      [Report] : Trunk Supervision calls using R1.5 trunk is
CROXES-24553        CROXES-22739   Major      endUser_customerSite
                                                                      NOK//00414000//
                                                                      [Report] : External caller hears noise and the attendant does not
CROXES-24238        CROXES-22833   Major      endUser_customerSite
                                                                      hear any audio in transfer scenario.
List of all Duplicates
 ISSUE KEY            MAIN CR      PRIORITY       HOW FOUND                                      SUMMARY
CROXE-13144         CROXES-23453   Major      endUser_customerSite    panic flag and OPS error
CROXE-16439         CROXES-23453   Major      endUser_customerSite    panic flag and OPS error on G729 server/client
21.2 M4.501.13 R12.3.1 MD3
List of all fixes
 ISSUE KEY           MAIN CR       PRIORITY       HOW FOUND                                       SUMMARY
                                                                       Wrong calling number/calling name in case of internal calls and
                                                                       forwarding to QSIG-GF trunk via "Open Routing
CROXE-14400     CROXE-14400        Minor      endUser_customerSite     Prefix"_//00409914//
CROXES-15396    CROXES-15396       Minor      endUser_betaSystem       8088 NOE German translation issues
                                                                       Cloud Connect - offer file retrieval - error during backup file
CROXE-14934     CROXE-14934        Major      endUser_prebetaSystem    creation when temporary files are generated
CROXE-16635     CROXE-16635        Minor      None                     Modified ver2cho.r script to install NSS packages
CROXE-16131     CROXE-16131        Minor      endUser_customerSite     [Related] : Security vulnerability - Step1
CROXES-23315    CROXES-23315       Major      endUser_customerSite     Sporadically impossible to use DECT sets
                                                                       Remote FWD to OOS Sip Extension with valid overflow not
CROXES-21824    CROXES-21824       Major      endUser_customerSite     working
CROXE-15409     CROXE-15409        Major      endUser_customerSite     GD3 Fan LED turns off when rescued by PCS
CROXE-15425     CROXE-15425        Major      validation_funcManual    OXE:M4- Multiple entries in call log after camp-on
                                                                       GD3 rebooted with the bactrace : * CPL *Backtrace:
                                                                       0xD24C7C9C NIP
CROXE-16147     CROXE-16147        Minor      endUser_customerSite     _ZN9EventMngr16EventMngr_assertEPcS0_i+0xa0/0xcc
CROXES-23375    CROXES-23375       Major      endUser_customerSite     DECThandset not reachable randomly / R12.3 sm4.302.18.h
CROXE-15384     CROXE-15384        Minor      endUser_customerSite     Backtrace - There is a new exception. Its address is :
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14              TC2632en-ed.06
Copyright © ALE International 2020                                                                             page 128/143
                                                                     0X083AAF8B serv=0 --> ctrl_numero_it
CROXES-22864   CROXES-22864    Major        endUser_customerSite     CAC is not released for some IP domain, reaching CAC limit
                                                                     Rainbow Media Pillar OXE: some audio lost cases after hold-
CROXES-22727   CROXES-22727    Must         endUser_acceptance       retrieve calls
                                                                     //1893_LSY// Voice-Mail Access from OXE to AVST Sometimes
CROXE-15379    CROXE-15379     Minor        endUser_customerSite     Fails
                                                                     no DTMF when transcoding from G729 (IPTouch) to G711 (SIP
CROXES-22934   CROXES-22934    Minor        endUser_customerSite     Extension) // 00414422// m4.302.18.f
                                                                     CCS stats no data in column " Actives Ressources" (agent grp
CROXE-15129    CROXE-15129     Minor        endUser_customerSite     stat)
                                                                     Interop: After many callback requests from ICM user to busy
CROXES-7628    CROXES-7628     Major        integration_funcManual   OXE user, ICM user is recalled many times
CROXES-23376   CROXES-23376    Major        endUser_prebetaSystem    Strong noise when nomadic user routed to mobile answers call
CROXES-23555   CROXES-23555    Minor        endUser_customerSite     DTMF not correctly transmitted during Early Media
CROXES-23738   CROXES-23738    Major        endUser_customerSite     Calling number is not correct on Rainbow client's Display
CROXE-13816    CROXE-13816     Major        endUser_customerSite     //1893F_LSY// Incident 2612
                                                                     INTIP boards are resetting after upgrade to 12.3 with the
CROXE-15795    CROXE-15795     Major        endUser_customerSite     backtraces._//00431230//
                                                                     crontab modification done by crontab -e are lost after cpu
CROXES-23033   CROXES-23033    Minor        endUser_customerSite     reboot
CROXES-22857   CROXES-22857    Major        endUser_customerSite     8242s called set hear heavy growl
List of all Reports
ISSUE KEY       MAIN CR         PRIORITY   HOW FOUND                   SUMMARY
                                                                       ID 09-1811 When user are disconnected we don't have the
CROXES-23859    CROXES-23350    Major      endUser_customerSite        busy tone. We are still in ringing on caller side.
                                                                       [Report] : OXE Accounting tickets - Called number only 8
CROXE-16381     CROXES-22800    Major      endUser_customerSite        digits long in tranzit call
                                                                       [Report] : No voice after transfer of a public SIP call to the
CROXE-16430     CROXES-21702    Major      endUser_customerSite        IAA by a SIP application
                                                                       [Report] : //1893F_LSY_RR//CCD/SIP OTCS : SIP INVITE
CROXE-16371     CROXE-13381     Major      endUser_customerSite        has bad 'to' field' in case of failover
                                                                       [Report] : Inbound SIP no audio when call picked up on
CROXE-16426     CROXE-12665     Major      endUser_customerSite        other node.
                                                                       [Report] : Agent on DECT 8242 with Bluetooth Headset are
                                                                       not availible when automatic WrapUp Time on Pilot is
CROXE-16425     CROXE-14047     Major      endUser_customerSite        configured
                                                                       [Report] : Wrong values for compressors retrieved by SNMP
CROXE-16405     CROXES-17343    Major      endUser_customerSite        linked to cnx dom// 1-219494841 // l2.300.36.a
                                                                       [Report] : Remote forwarding not working with DECT set in
CROXE-16395     CROXES-22695    Major      endUser_customerSite        ABC-F Network
CROXE-16403     CROXE-13171     Major      endUser_customerSite        [Report] : Alarmserver urgent broadcast on devices wirh set
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14           TC2632en-ed.06
Copyright © ALE International 2020                                                                          page 129/143
                                                                        supervision team display of 'please hangup'
                                                                        [Report] : SIPMOTOR crashes due to backtrace
CROXE-16416     CROXES-21893    Major      endUser_customerSite         CMotorTimerSynchroniseStdBy::treateTimeO
                                                                        [Report] : OXE:M3// Column misalignment of Type, DSU, DS
CROXE-16450     CROXES-22757    Major      validation_funcManual        field in "ippstat d" command
                                                                        [Report] : No direct rtp between OXE IPT and OXO behind
CROXE-16431     CROXE-13204     Major      endUser_customerSite         SIP.
                                                                        [Report] : Getting Backtrace while executing "compvisu lio"
CROXE-16428     CROXES-22045    Major      endUser_customerSite         command.//00388805//
                                                                        [Report] : CLI issue with UTF-8 character in Korean
CROXE-16427     CROXES-21645    Major      endUser_customerSite         language.
                                                                        [Report] : OXE:M3: No RBT for SIPISDN Calls from
CROXE-16417     CROXES-20063    Major      validation_funcManual        Restricted Domain(g729) set
                                                                        [Report] : 4645 distributed list mail box number shows as
CROXE-16379     CROXES-22969    Major      endUser_customerSite         out of service when dialed. Not able to leave message.
                                                                        [Report] : When PCS is in INACTIVE* mode, xBS don't
CROXES-24098    CROXES-21432    Major      endUser_customerSite         remain attached to the PCS
                                                                        [Report] : [Related] : //1893_OT_RR// OTC App Error on
CROXES-24096    CROXES-22978    Major      endUser_customerSite         forwarding busy or no answer
CROXES-24074    CROXES-22773    Major      endUser_customerSite         [Report] : Wrong PAI in "180 Ringing" sent to a SIP device
                                                                        [Report] : [Related] : Since the installation of Hotfix 999 call
CROXES-24093    CROXES-23732    Major      endUser_customerSite         forwarding via mgr is no longer possible on some devices.
                                                                        [Report] : Probleme d'allocation compresseur dans une
CROXES-24045    CROXES-23743    Major      endUser_customerSite         configuration avec WebRTCGateway
                                                                        [Report] : OT15_MD4/Can't associate OTC Smartphone
CROXES-24010    CROXES-23943    Major      validation_funcManual        device to a CT user - PMS error
                                                                        [Report] : M5-corrections to download 8088 terminal type
CROXE-16924     CROXE-16831     Major      software                     binaries from OXE to OST
                                                                        [Report] : M5-CI: Call log process occupying more than 95%
CROXE-16855     CROXE-16629     Major      integration_continuousTest   of CPU
                                                                        [Report] : one way communication when blind transfer to
CROXES-24033    CROXES-23791    Major      endUser_customerSite         tandem remote worker
                                                                        [Report] : loss service Tel rainbow during 15mn after bascul
CROXE-16497     CROXE-15678     Major      endUser_alpha                in M5.200.4.a
                                                                        [Report] : RBT is not proper for external calls via transit
CROXES-24070    CROXES-24064    Major      endUser_alpha                node
                                                                        [Report] : Modified inst_common script in rload to install nss
CROXES-24183    CROXE-16891     Major      software                     packages
                                                                        [Report] : OXE SIP/TLS trunk does not work anymore after
CROXES-24135    CROXES-22776    Major      endUser_betaSystem           upgrade to R12.3.1
                                                                        [Report] : Impossible to answer an alarm call on DECT if
CROXES-24028    CROXES-23742    Major      endUser_customerSite         digit key is pressed accidentially OXE R12.2 m3.402.25.a
CROXE-16382     CROXES-22057    Major      endUser_customerSite         [Report] : Incidents 1603 and 1607 recurrent//00387529//
                                                                        [Report] : OXE:M3// Improper display of ringing indication
CROXE-16406     CROXES-23218    Major      validation_funcManual        tabs for Boss/Secretary call
CROXES-24095    CROXES-23322    Major      validation_funcManual        [Report] : OXE/M3: Wrong destination type After
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14            TC2632en-ed.06
Copyright © ALE International 2020                                                                           page 130/143
                                                                        forwarding(fwd on busy/fwd on no ans) to voicemail
CROXE-16384     CROXES-12609    Major      endUser_prebetaSystem        [Report] : nomadic ghostz busy with AUXRA
CROXE-16389     CROXE-14735     Major      endUser_customerSite         [Report] : DTMF not working with IPDECT
                                                                        [Report] : Unable to access OT Voicemail when calling a
                                                                        CCD pilot set - Voicemail Server does not recognize the
CROXES-24146    CROXES-23558    Major      endUser_customerSite         VoiceMail Box
                                                                        [Report] : Incident 2650=SQL error: appli CMIS_SAVE table
CROXE-16447     CROXES-21104    Major      endUser_customerSite         NOE_PARAM error 100
                                                                        [Report] : After a DOUBLE MAIN situation, prefered CS (CPU
                                                                        A) reboots since CPU B is connected to Reference Media
CROXE-16396     CROXES-23022    Major      endUser_customerSite         Gateway while Reference M/G is not configured
CROXE-16434     CROXE-12445     Major      endUser_customerSite         [Report] : Recording has no audio
CROXE-16848     CROXE-14809     Major      validation_funcManual        [Report] : OXE M5: UA virtual not listed to sync with rainbow
CROXE-16448     CROXE-14134     Major      endUser_customerSite         [Report] : Dect-User"no response from system"
                                                                        [Report] : Some incoming public SIP call to a TDM set in a
CROXE-16365     CROXES-23027    Major      endUser_customerSite         peripheral shelf behind INTOF fails
                                                                        [Report] : [Related] : Communication without audio between
                                                                        OXO user called from his Rainbow on mobile a user OTC PC
CROXE-16386     CROXES-22313    Major      endUser_prebetaSystem        on OXE node.
                                                                        [Report] : The EWT is getting higher and higher.because the
CROXE-16402     CROXE-14426     Major      endUser_customerSite         number of ACR cal is not correct in alb process
                                                                        [Report] : [Related] : //1893_OT_RR// OTC Web can not call
CROXES-23871    CROXES-20769    Major      endUser_customerSite         muti-device user when Main set is out of service
                                                                        [Report] : [Related] : No immediate forwarding to SIP
CROXE-16400     CROXES-22077    Major      endUser_customerSite         Extension when OTC PC disconnected
                                                                        [Report] : Dual CSTA event from OXE sip calls creating for
CROXE-16423     CROXE-12982     Major      endUser_customerSite         Recorder in OXE .
                                                                        [Report] : OXE-M5:New Linux
                                                                        package(r_linux26_patch_160.007) is not Installed with
CROXE-16597     CROXE-16433     Major      integration_funcManual       m5.202.5
List of all Duplicates
ISSUE KEY       MAIN CR         PRIORITY   HOW FOUND                SUMMARY
                                                                    GE: REGRESSION: Bad German translation for missed calls
CROXE-16311     CROXES-15396    Major      endUser_customerSite     AGAIN / OXE / R12.x
                                                                    AT: DECT: Sporadically impossible to answer / rewiew ALARM on
CROXES-23286    CROXES-23742    Major      endUser_customerSite     DECT sets / OXE / R12.3 sm4.302.18.h
                                                                    OXE:M4// Answered incoming call is updated as missed call in
CROXES-23897    CROXE-15425     Major      validation_funcManual    Call log - Boss/Secretary Sets
                                                                    ctrl_numero_it backtraces from Standby CPU - m4.302-18-h
CROXES-23917    CROXE-15384     Minor      endUser_customerSite     //00445760//
                                                                    //1893_LSY//OXE (m230022a) do not get SIP ACK msg while
CROXE-16534     CROXE-15379     Major      endUser_customerSite     working with AVST Rel9.0.2 build 1712
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14          TC2632en-ed.06
Copyright © ALE International 2020                                                                         page 131/143
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 132/143
21.3 M4.501.12.A R12.3.1 MD2
List of all Reports
 ISSUE KEY          MAIN CR    PRIORITY        HOW FOUND                                        SUMMARY
                                                                    [Report] : OT15_MD4/Can't associate OTC Smartphone device to
CROXES-24102    CROXES-23943   Major        validation_funcManual   a CT user - PMS error
                                                                    [Report] : One way communication when blind transfer to
CROXES-24106    CROXES-23791   Major        endUser_customerSite    tandem remote worker
                                                                    [Report] : [Related] : //1893_OT_RR// OTC App Error on
CROXES-24109    CROXES-22978   Major        endUser_customerSite    forwarding busy or no answer
                                                                    [Report] : [Related] : ID 09-1811 When user are disconnected
CROXES-24103    CROXES-23350   Major        endUser_customerSite    we don't have the busy tone. We are still in ringing on caller side.
                                                                    [Report] : CCS stats no data in column " Actives Ressources"
CROXE-16879     CROXE-15129    Major        endUser_customerSite    (agent grp stat)
                                                                    [Report] : Calling number is not correct on Rainbow client's
CROXES-24110    CROXES-23738   Major        endUser_customerSite    Display
                                                                    [Report] : [Related] : Since the installation of Hotfix 999 call
CROXES-24107    CROXES-23732   Major        endUser_customerSite    forwarding via mgr is no longer possible on some devices.
                                                                    [Report] : //1893_LSY//8088 Phone On Hook Button Red and not
CROXES-24113    CROXES-23253   Major        endUser_customerSite    working
                                                                    [Report] : OXE/M3: Wrong destination type After forwarding(fwd
CROXES-24108    CROXES-23322   Major        validation_funcManual   on busy/fwd on no ans) to voicemail
                                                                    [Report] : CAC is not released for some IP domain, reaching CAC
CROXES-24111    CROXES-22864   Major        endUser_customerSite    limit
                                                                    [Report] : Remote FWD to OOS Sip Extension with valid overflow
CROXES-24112    CROXES-21824   Major        endUser_customerSite    not working
                                                                    [Report] : Unable to access OT Voicemail when calling a CCD
CROXES-24145    CROXES-23558   Major        endUser_customerSite    pilot set - Voicemail Server does not recognize the VoiceMail Box
21.4 M4.501.12
List of all fixes
ISSUE KEY       MAIN CR        PRIORITY     HOW FOUND                 SUMMARY
CROXES-23740    CROXES-23740   Blocker      validation_funcManual     Unable to load m4.501.12 #2
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14             TC2632en-ed.06
Copyright © ALE International 2020                                                                            page 133/143
CROXES-22919   CROXES-22919    Major        endUser_customerSite    CSR Signing (Local)
CROXES-22920   CROXES-22920    Major        endUser_betaSystem      CSR Import PKCS#12 / PKCS#7
CROXE-15188    CROXE-15188     Major        endUser_customerSite    crash of both CPU after forward in loop
                                                                    //1893_LSY_RR// GE: Call log doesn't store missed call for
                                                                    busy user without Multiline with camp-on enabled / OXE /
CROXE-12714    CROXE-12714     Major        endUser_customerSite    R12.3 m4.302.5.a
CROXE-15277    CROXE-15277     Minor        endUser_customerSite    CCD - Pro-acd acd station in tandem configuration
CROXES-23224   CROXES-23224    Major        endUser_customerSite    SIP REFER impossible with long number with RSI
                                                                    CSTA wrong callback translator used when calling busy
CROXES-23011   CROXES-23011    Major        endUser_customerSite    subscriber
CROXES-23214   CROXES-23214    Major        validation_funcManual   SIP URL Domain parameter is not showing in mgr
CROXES-23752   CROXES-23752    Major        validation_funcManual   m4.501.12 #3: Backtrace observed during RUNTEL
CROXES-23219   CROXES-23219    Minor        endUser_customerSite    Prefix plan shows double entire//00472472//
                                                                    sipextgw tool does not reflect well the value Send user name in
CROXES-23444   CROXES-23444    Minor        endUser_prebetaSystem   SIP
CROXE-14090    CROXE-14090     Minor        endUser_customerSite    ALE PROD: OXE phonebook stuck in R12.3
                                                                    The country code is missing for supervised calls via the Set
CROXE-14786    CROXE-14786     Minor        endUser_customerSite    Supervision key
CROXE-13540    CROXE-13540     Minor        software_analysisTool   OXE M4 : Klockwork- Array tab_mevo.Item' initialization issue
                                                                    [Related] : Since migration in 12.3.1 , the call log visually
                                                                    notifies (message lamp) unanswered calls (for example on all
CROXES-23679   CROXES-23679    Minor        endUser_customerSite    posts in a hunting group ) - MAO System Option
CROXE-14456    CROXE-14456     Major        endUser_customerSite    DECT sets ringing delayed_//00412060//
CROXES-23358   CROXES-23358    Major        None                    SRTP keys printed in Socket Agent traces
CROXE-15973    CROXE-15973     Major        endUser_customerSite    //1893_LSY//OXE 12.3.1: calllog issue
                                                                    Non-void function does not return value // KWID-58234// OXE
CROXE-15726    CROXE-15726     Major        software_analysisTool   DEV
                                                                    GE: REGRESSION: Call log not accessible via red LED key / OXE
CROXES-23720   CROXES-23720    Major        endUser_customerSite    / R12.3.1 m4.501.10.f
                                                                    Since migration in 12.3.1 , the call log visually notifies
                                                                    (message lamp) unanswered calls (for example on all posts in a
CROXES-23326   CROXES-23326    Minor        endUser_customerSite    hunting group )
CROXES-23072   CROXES-23072    Critical     validation_funcManual   Unable to hear RBT when the DECT calls IP Touch/TDM sets
List of all Reports
 ISSUE KEY       MAIN CR       PRIORITY            HOW FOUND                                  SUMMARY
                                                                     [Report] : CSTA Not possible to active on hold from a DECT
CROXE-15680    CROXE-13146     Major        endUser_labSystem        set by CSTA
CROXE-16212    CROXE-14563     Major        review                   [Report] : [Feature ] Simple upgrade of OXE patchs
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14         TC2632en-ed.06
Copyright © ALE International 2020                                                                        page 134/143
                                                                       [Report] : Wrong spelling of the "Category 1" parameter (mgr
CROXES-23710   CROXES-22048    Major        endUser_customerSite       > Categories > Transfer Category) in French
                                                                       [Report] : All phones are unable to make internal or external
CROXE-16029    CROXE-13780     Major        endUser_customerSite       calls until a double BASCUL//00401014
                                                                       [Report] : MAO error occurs when the user remove the
CROXES-23688   CROXES-22853    Major        validation_funcManual      directory name
                                                                       [Report] : M5-NRT: LED still blinking when call log accessed
CROXE-15853    CROXE-14901     Major        validation_nonRegression   by prefix
                                                                       [Report] : Wrong spelling of the "Unattended Transfer for
CROXES-23697   CROXES-21962    Minor        endUser_customerSite       RSI" parameter (SIP external gateway) in French
                                                                       [Report] : GE: REx: Remote Extension Network doesn't start +
                                                                       Exceptions init_remote_nwk with incidents 5904 and 1721 /
CROXES-23676   CROXES-23268    Major        endUser_customerSite       OXE / R12.2 m3.402.25.a
CROXES-23673   CROXES-23392    Major        endUser_customerSite       [Report] : // 1893F_LSY_RR // Question about SSH on OXE
                                                                       [Report] : Need to close port 80(unnecessarily opened by
CROXE-16106    CROXE-15681     Major        software                   Nginx)
                                                                       [Report] : special character for proxy do not work and full
CROXES-23671   CROXES-22782    Major        endUser_customerSite       fqdn for proxy name does not work
                                                                       [Report] : Rainbow : impossible to have a connection to
CROXES-23670   CROXES-22304    Major        endUser_customerSite       openrainbow.com because of domain name
CROXE-16105    CROXE-15738     Major        software                   [Report] : CS-2 reboots in case of POWER DOWN request
                                                                       [Report] : 4645 Voice Guides after 2020: Need to remove an
CROXE-16203    CROXE-15049     Major        None                       incident
CROXES-23521   CROXES-22127    Major        endUser_customerSite       [Report] : //OTHER// Error during Faxtransmission
                                                                       [Report] : H323 trunk calls forwarded to external disconnected
                                                                       by INTIP3 (timer) linked to delay to get ALERT from T2 //
CROXES-23516   CROXES-22560    Major        endUser_customerSite       00404678// m3.402.25
                                                                       [Report] : FW Enhancement: Automation of on-hook tone
CROXES-23517   CROXES-17719    Major        review                     detector parameters for APA trunk
                                                                       [Report] : GD3/INTIP3: Bug in source code with Thales
CROXES-23513   CROXES-21096    Major        software                   context
                                                                       [Report] : //1893_LSY_RR// GE-R12.2 - Frequently reboots of
CROXES-23511   CROXES-20885    Major        endUser_customerSite       ACT's behind IOIP3 after IOIP3 crash with backtrace
                                                                       [Report] : GD3/INTIP3: ATTR_MCC field is not coherent than
CROXES-23515   CROXES-21500    Major        software                   enum LIOEM_MCC
CROXES-23514   CROXES-21499    Major        software                   [Report] : GD3/INTPIP3: Fax SIP overflow on maxSizeCbTb
CROXES-23512   CROXES-21425    Major        review                     [Report] : NGP_9.xx: trace suppression
                                                                       [Report] : No voice connection when calling of user with
CROXE-15709    CROXES-18254    Major        endUser_customerSite       active forwarding to 4645 voicemail
                                                                       [Report] : SOSM messages 1.1-1.3 issue : "selection feature"
CROXE-15672    CROXE-11106     Major        endUser_acceptance         does not change to "statistical" in specific case
                                                                       [Report] : [Related] : No call forwarding to the tandem device
CROXES-23328   CROXES-22531    Major        endUser_customerSite       if the SIP Extension (Main set) is Out of Service
                                                                       [Report] : In a Master conference scenario, master is hearing
                                                                       the RBT until all the users in the conference group list picks
CROXE-15724    CROXE-11272     Major        endUser_customerSite       up the call via SIP TG.
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14           TC2632en-ed.06
Copyright © ALE International 2020                                                                          page 135/143
                                                                     [Report] : since R12 migration crash of CPU very oftern
CROXE-15723    CROXES-17304    Major        endUser_customerSite     without logs
CROXE-15722    CROXE-11214     Major        endUser_customerSite     [Report] : SIPMOTOR restarted.
                                                                     [Report] : Incorrect filling of the SIP field "TO" following a call
CROXE-15720    CROXE-12524     Major        endUser_customerSite     transfer from an agent to an RSI point
CROXE-15718    CROXE-12164     Major        endUser_demoSystem       [Report] : Incident 412 not working
                                                                     [Report] : While switching from 8058s to 8068s with MLA
CROXE-15716    CROXE-12099     Major        endUser_customerSite     keys, switching fails and time is not displayed on the screen
                                                                     [Report] : SOSM issue when re-stop with the initial password (
CROXE-15671    CROXE-11105     Major        endUser_acceptance       No transmission to the CP of message )
                                                                     [Report] : SOSM Data transfer request and MCL/Group
                                                                     correspondence issue ( not defined in the TT channels for the
CROXE-15670    CROXE-11103     Major        endUser_acceptance       PABX of given capacity )
CROXE-15660    CROXES-14988    Major        endUser_customerSite     [Report] : After RSI call to agent, wrap up is cancel
                                                                     [Report] : [Related] : sequential group: the external
CROXE-15658    CROXES-22176    Major        validation_funcManual    incoming call is ended on the first disconnected mobile
CROXE-15667    CROXE-11102     Major        endUser_acceptance       [Report] : SOSM MCL voice tract Connect by command issue
CROXE-15666    CROXE-11101     Major        endUser_acceptance       [Report] : SOSM MCL assignment issue
                                                                     [Report] : SOSM Remote Control does not receive messages
                                                                     1.4 about the order/cancellation by the subscriber of the
CROXE-15732    CROXE-11107     Major        endUser_acceptance       Supplementary Services.
                                                                     [Report] : SOSM SS (conf) Point 9.4 step 12 no message MCL
CROXE-15652    CROXE-14140     Major        endUser_customerSite     not released
                                                                     [Report] : Sometimes, there are no digits in the messags 1.3
CROXE-15651    CROXE-14427     Major        endUser_customerSite     when user make "insignificant" call
                                                                     [Report] : //S3 requested// Incorrect display of diversion info
CROXE-15649    CROXE-14015     Major        endUser_customerSite     on the terminal device
                                                                     [Report] : Check-in language is not applied automatically in IP
CROXE-15648    CROXE-12919     Major        endUser_customerSite     DECT 8242 hotel suit guest extensions.
                                                                     [Report] : SOSM SS (chain forward) Point 2.4 step 1 no
CROXE-15647    CROXE-14138     Major        endUser_customerSite     message 1.1 if all A,B,C, D under control
                                                                     [Report] : No Ring Back Tone on T2, when an incoming call
CROXE-15655    CROXE-14009     Major        endUser_customerSite     transit via OXE to Third Party SIP PBX
                                                                     [Report] : SS (CS) Point 6.3 step 10 Code value is 04 instead
CROXE-15654    CROXE-14428     Major        endUser_customerSite     of 05 call
                                                                     [Report] : GE: Beta: OXE Call log translation issue / OXE /
CROXE-14811    CROXE-14443     Major        endUser_betaSystem       R12.3.1 m4.501.1.a
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14           TC2632en-ed.06
Copyright © ALE International 2020                                                                          page 136/143
                                                                       [Report] : //1893F_LSY_RR// Cloud Connect Procedure RTR
CROXES-23674    CROXES-23194   Major        endUser_customerSite       Status NOK Code 603 : CNX/DCNX every 2 minutes
CROXES-23715    CROXES-22783   Major        endUser_customerSite       [Report] : Command "compvisu eqt" aborts with backtrace
                                                                       [Report] : M5 Direct RTP: NRT- Call released when SEPLOS in
CROXE-16115     CROXE-15827    Major        validation_funcManual      hold state
                                                                       [Report] : Cloud Connect - oxe remote console - After
                                                                       execution of command incvisu or uhwconf the session is very
CROXE-15477     CROXE-14011    Blocker      validation_funcManual      slow then session timout, it is not possible to reconnect
                                                                       [Report] : OT15/Option 'can be called/dialled by name' is set
CROXE-14884     CROXE-13182    Major        validation_funcManual      to false if user created using OXE profile in 8770
                                                                       [Report] : LAB: Cloud Connect netadmin menu needs
CROXES-23668    CROXES-20708   Major        endUser_labSystem          formatting
CROXES-23520    CROXES-21107   Major        endUser_customerSite       [Report] : OT | Incoming Fax transmission error
                                                                       [Report] : Cloud Connect - Remote console - ccagent or
                                                                       ccservices service not restarted for the command "service
CROXE-15502     CROXE-15346    Major        validation_funcManual      ccagent or ccservices restart" executed from remote console
CROXES-23499    CROXES-22912   Major        endUser_customerSite       [Report] : Dect-User"no response from system"
                                                                       [Report] : //1893_CCD_RR// 377412_Wrong Information in
                                                                       CSTA when Call goes through ABCF Hybridlink and Call is
CROXE-15703     CROXE-12984    Major        endUser_customerSite       transferred by a SIP Application
List of all Duplicates
 ISSUE KEY         MAIN CR     PRIORITY        HOW FOUND                                      SUMMARY
                                                                    Non-replied call is stored on the called set when the call gets
CROXES-23468    CROXES-23326   Major        validation_funcManual   overflowed and answered
                                                                    To disable the MWI notification for unanswered internal and
CROXE-15830     CROXES-23326   Minor        endUser_customerSite    external calls._//00433434//
                                                                    Caller Number is updated incorrectly in unanswered call When
CROXES-23467    CROXES-23326   Major        validation_funcManual   set do the network substitution call
                                                                    After Update from Rel.12.3 to 12.3.1 Call log is not working
CROXES-23620    CROXES-23326   Major        endUser_customerSite    correctly
                                                                    //1893_LSY//Call log of missed calls on phone sets with set
CROXES-23440    CROXES-23326   Minor        endUser_customerSite    supervision keys
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14            TC2632en-ed.06
Copyright © ALE International 2020                                                                           page 137/143
CROXES-23415    CROXES-23326   Major        endUser_customerSite    Call Pick up -> Unanswered call
                                                                    Set Supervision are signaled as unanswered on the called
CROXES-23334    CROXES-23326   Major        endUser_customerSite    telephone after 12.3.1 update.
                                                                    Internal call:Message LED blinks, although ISDN User/Internal
CROXE-15739     CROXES-23326   Major        endUser_customerSite    is set to false
                                                                    beta-OXE R12.3.1 Dect reacts very slow or no answer from
CROXES-22952    CROXE-14456    Major        endUser_betaSystem      system, if "Allow auto FW update of sets + YES"
CROXES-23471    CROXES-23326   Minor        endUser_customerSite    Call Log message LED behavior and internal calls storage
                                                                    //1893_LSY//unanswered calls in the call list although the user
CROXE-16023     CROXES-23326   Minor        endUser_customerSite    is busy
                                                                    REX: Remote Extension Network doesn't start + Exceptions
                                                                    init_remote_nwk with incidents 5904 and 1721 / OXE / R12.3
CROXES-23448    CROXES-23268   Critical     endUser_customerSite    m4.302.5.h
                                                                    Since update of OXE to 12.3.1 not possible to switch off
CROXES-23619    CROXES-23326   Major        endUser_customerSite    message LED for internal missed calls/if in conversation
CROXE-15972     CROXE-15973    Major        endUser_labSystem       Problem with non replied call list / call log - set blocks
                                                                    OXE 12.3.1: Group Call Pickup creates unanswered call on
CROXES-23612    CROXES-23326   Minor        endUser_customerSite    initially called set
21.5 M4.501.11 R12.3.1 MD1
List of all fixes
 ISSUE KEY          MAIN CR    PRIORITY          HOW FOUND                                        SUMMARY
                                                                       OXE Rainbow CCTool failed - can't create lock ..file was not
CROXES-22326    CROXES-22326   Minor        endUser_customerSite       created.
                                                                       M4 NRT: White call communication observed during blind
CROXE-14441     CROXE-14441    Major        validation_nonRegression   transfer call answer via hands-free mode
CROXE-15041     CROXE-15041    Minor        software                   OXE M4 - Code Removal of CROXE-12291
                                                                       FNSE: INTIP3A don't use DTLS in remote ACT using INTOF
CROXES-22831    CROXES-22831   Minor        endUser_customerSite       links
                                                                       R12.3.1: Nulog & Numan field not updated for Consult
CROXE-14836     CROXE-14836    Major        validation_funcManual      Multilines And Supervised Sets in "Multitool CHECK" command
                                                                       [Related] : servicability request for IP-xBS synchronization
CROXE-13887     CROXE-13887    Major        endUser_prebetaSystem      tree splits OXE part
                                                                       M4:SIP Trunk Recording: UsertoUser not sent in 200OK
CROXE-13226     CROXE-13226    Blocker      validation_funcManual      network pilot call when network agent is monitored
CROXES-22775    CROXES-22775   Critical     endUser_customerSite       Voice over IP not working
                                                                       M4-NRT: PCS rescued Sets should not display the call log
                                                                       option in menu page and set get freeze while accessing call
CROXE-14696     CROXE-14696    Major        validation_nonRegression   log
                                                                       GE: Incorrect display on the Z-set, when SIP trunk has Special
CROXES-22747    CROXES-22747   Minor        endUser_customerSite       Service = Urgent Broadcast / OXE / R12.1 sm2.300.24
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14              TC2632en-ed.06
Copyright © ALE International 2020                                                                             page 138/143
CROXES-22437   CROXES-22437    Blocker      endUser_customerSite     CCD - Main_afe process doesn't start
                                                                     M4 WebRTC GW : ON HOLD external user losses it hold tone
CROXE-14483    CROXE-14483     Major        validation_funcManual    when enquiry call is made by rainbow client
CROXE-14651    CROXE-14651     Major        endUser_alpha            ALPHA : Unanswered calls not displayed on DECT tandem
                                                                     OXE:M3: Heavy noise when seplos user hold&retrive a NW
CROXES-21397   CROXES-21397    Blocker      endUser_customerSite     user
CROXES-19244   CROXES-19244    Major        validation_funcManual    8078s set resets when logged in as DSU
                                                                     //After migrating OXE from R11.0.1 to R12.3, database
CROXES-22954   CROXES-22954    Major        endUser_customerSite     inconsistencies observed//
CROXE-14123    CROXE-14123     Critical     endUser_alpha            Alpha nu11 : Campus incoming call KO
List of all Reports
 ISSUE KEY       MAIN CR       PRIORITY          HOW FOUND                                     SUMMARY
                                                                      [Report] : [Related] : [Feature] Creation of Serbian country
CROXES-23085   CROXE-14049     Major        review                    variant-Swinst part
                                                                      [Report] : [prebeta OXE] database periodic backup doesnt
CROXES-23074   CROXES-22713    Major        endUser_prebetaSystem     work in m4, the line is missing in crontab
                                                                      [Report] : AT: mailsys process sporadically blocked and no
                                                                      incidents / Omnivista Alarms anymore / OXE / R12.1
CROXE-15217    CROXE-11830     Major        endUser_customerSite      m2.300.20
                                                                      [Report] : LDI Handle correctly session timer with RE-
CROXE-15354    CROXES-22572    Major        endUser_customerSite      INVITE in SIP-tLS SRTP
                                                                      [Report] : Panic Flag SWK because of software lock 328 IP-
CROXE-14897    CROXE-12243     Major        endUser_customerSite      Softphone Attendants exceeded.
                                                                      [Report] : Frequently incidents 4403=Error 8 on message
CROXE-14882    CROXE-12439     Major        endUser_customerSite      type 1 on timeslot x is generated
                                                                      [Report] : M4 IP DRlink VG play on OXE for OPR: VG
CROXE-14704    CROXE-14178     Major        endUser_labSystem         broadcasted to Agent and External party in discrete listening
CROXES-22787   CROXES-22013    Major        endUser_customerSite      [Report] : vulnerabilities Oxe R12.2
                                                                      [Report] : OXE users gets connected to voice guides or one
CROXE-14910    CROXES-21638    Major        endUser_customerSite      way call during external calls after some time//00375884//
                                                                      [Report] : 1st digit is missing in the display of 8018,8058s
CROXE-14909    CROXES-21818    Major        endUser_customerSite      during Incoming call
                                                                      [Report] : INTOF2A remains in wait link after inter act link
CROXES-23084   CROXE-12676     Major        endUser_customerSite      loss or power fail
                                                                      [Report] : GE: Database change on Main-CPU not taken into
CROXE-15066    CROXES-22517    Major        endUser_customerSite      account on Stand-By CPU / OXE / R12.2 m3.402.25
                                                                      [Report] : SIP TLS and ABCF2 network : End of call after
CROXE-15353    CROXES-22433    Major        endUser_customerSite      blind transfer to remoteworker
CROXE-14991    CROXE-14791     Major        endUser_prebetaSystem     [Report] : Request to RnD to integrate new infocollect 5.8
                                                                      [Report] : audio issue with calls recorded through
CROXE-14880    CROXE-12664     Major        endUser_customerSite      Packetyzer
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14         TC2632en-ed.06
Copyright © ALE International 2020                                                                        page 139/143
CROXE-15036    CROXE-12415     Major        endUser_customerSite      [Report] : Lot of checkdb errors after upgrading to R12.2
                                                                      [Report] : System crashes with 1640=Internal Monitel error
CROXE-14877    CROXES-21579    Major        endUser_customerSite      no 3, line 11745, file 68 error GAP_HANDSET exception
                                                                      [Report] : Problems with incoming SIP Calls after upgrade to
CROXE-14895    CROXES-21937    Major        endUser_customerSite      Rel 12.2
CROXES-23121   CROXES-22820    Major        endUser_betaSystem        [Report] : ippstat tool in native encryption
                                                                      [Report] : [Related] : OXE Phonebook Freefield is cleared
                                                                      when OTC Smartphone or OTC PC is added or user name is
CROXE-14849    CROXES-21925    Major        endUser_customerSite      changed
                                                                      [Report] : SOSM a lot messages 2.2 for already
CROXE-14853    CROXE-12531     Major        endUser_customerSite      disconnected calls coming
                                                                      [Report] : Issue of DTMF - not recognized by SIP Server of
CROXE-14911    CROXE-11415     Major        endUser_customerSite      conference
CROXE-15611    CROXE-13230     Major        endUser_customerSite      [Report] : DTMF is not taken into account.
                                                                      [Report] : An incoming SIP-ABCF call internally transferred
CROXE-14918    CROXES-21776    Major        endUser_customerSite      can't be put on hold by the remote SIP party
                                                                      [Report] : Urgent broadcast call to Agent - CC Tab in Menü
CROXE-15396    CROXE-11973     Major        endUser_customerSite      on phones disappears
                                                                      [Report] : DTMF Tones are being sent automatically to the
CROXE-14827    CROXES-21527    Major        endUser_customerSite      calling extension on ISDX when Call is answered on OXE.
                                                                      [Report] : //1893F LSY_ESC// Incident 2678 Error IPC
CROXE-14915    CROXE-11208     Major        endUser_customerSite      SEND: appli CMISE
                                                                      [Report] : M5:Unable to send voice mail using softkey only
CROXE-15310    CROXE-14553     Major        integration_funcManual    with ABCF-IP in IP sets
                                                                      [Report] : Called/Dialed by Name and busy camp is not
CROXE-14889    CROXE-13725     Major        endUser_customerSite      working correctly //00398050
                                                                      [Report] : [Related] : //1893_OT_RR// MIGROS : OTC
                                                                      Smartphone VoIP - No Voip when switching to mobile
CROXE-14851    CROXES-21993    Major        endUser_customerSite      network
                                                                      [Report] : Error "Software problem in restricted_map_dcom
CROXE-14893    CROXES-22423    Major        endUser_customerSite      !!!" when using "dectview com"
                                                                      [Report] : N1: GCC/Glibc : Unable to configure redundancy
CROXE-15312    CROXE-14684     Major        validation_funcManual     EGW parameter in mgr
CROXE-15356    CROXE-7867      Major        endUser_customerSite      [Report] : CAC counter randomly blocked in one IP domain.
CROXE-15614    CROXE-13909     Major        endUser_customerSite      [Report] : download of voice guide blocked for OMS
                                                                      [Report] : Attendant's call to entity call prefix fails if set is
CROXE-14875    CROXE-10058     Major        endUser_customerSite      CDT is forwarded to voicemail
                                                                      [Report] : M4 Alpha : All the coupler's getting down due
CROXES-23086   CROXE-14676     Major        endUser_alpha             External EGW not sync with OXE
                                                                      [Report] : Cloud Connect - oxe remote console - After
                                                                      execution of command incvisu the session is very slow then
CROXE-15251    CROXE-14011     Major        endUser_prebetaSystem     session timout, it is not possible to reconnect
                                                                      [Report] : Cloud Connect: Unable to restart ccagent service
CROXE-15344    CROXE-14430     Major        software                  after a crash
                                                                      [Report] : Cloud Connect: Unable to restart ccservices
CROXE-15345    CROXE-14431     Major        software                  service (Remote Console) after a crash
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14            TC2632en-ed.06
Copyright © ALE International 2020                                                                           page 140/143
                                                                         [Report] : RSI : Caller does not ear the VG when calling
CROXE-14916    CROXE-12584     Major        endUser_customerSite         from SIP trunk
                                                                         [Report] : M3-CI: Calling number not displayed on called
CROXE-14945    CROXES-22830    Major        integration_continuousTest   party during network call
CROXE-14854    CROXE-12530     Major        endUser_customerSite         [Report] : SOSM unexpected 0F in reply of command 10
CROXE-14831    CROXE-12535     Major        endUser_customerSite         [Report] : SOSM Attribute of phone number
CROXE-14845    CROXE-12534     Major        endUser_customerSite         [Report] : SOSM test 8.2
CROXE-14852    CROXE-12533     Major        endUser_customerSite         [Report] : SOSM no Music on Hold in MCL
                                                                         [Report] : OXE no longer generates Obstraf pmm tickets
CROXE-15334    CROXES-21635    Major        endUser_customerSite         under /usr4/pmm
CROXE-15633    CROXE-11894     Major        endUser_customerSite         [Report] : Protel Synronisation via AHL doesn't work
CROXES-23192   CROXES-20605    Major        endUser_customerSite         [Report] : remote install PCS fails
                                                                         [Report] : Array 'number' of size 18 may use index value(s)
CROXE-14825    CROXES-22675    Major        software_analysisTool        18 // KWID-58184 // CCX
CROXE-14829    CROXE-12537     Major        endUser_customerSite         [Report] : SOSM not complect list of SS in command 12
                                                                         [Report] : On SIP-ABCF forwarded calls, "transport=TCP" is
                                                                         missing in the Contact header of the 302 when the URI of
CROXE-14917    CROXES-21338    Major        endUser_customerSite         the Contact contains the OXE
                                                                         [Report] : SIP calls remain as inactive with State =
CROXE-15323    CROXE-11936     Major        endUser_customerSite         INITIAL_STATE
                                                                         [Report] : CCD Agent receives a distributed call. This agent
CROXE-14908    CROXES-21604    Major        endUser_customerSite         does an enquiry call to the user in the second node
                                                                         [Report] : M4-NRT: "Events" option is displayed in menu
CROXE-14808    CROXE-14624     Major        validation_nonRegression     page when call log access option is enabled
CROXE-14874    CROXE-9227      Major        endUser_customerSite         [Report] : 8242 blocked : No answer from system
                                                                         [Report] : By abc link, Overflow on 2nd routing number of
                                                                         ENTITY CDT is not working in case of timer 102 expiration
CROXE-15615    CROXE-13953     Major        endUser_customerSite         before of timer overflow_//00390193//
                                                                         [Report] : Set type is "NOE_C_COLO" in listerm all for 8039s
CROXE-14912    CROXE-12211     Major        endUser_customerSite         set.
                                                                         [Report] : //Supervised transfer from VAA is not working if
CROXES-23329   CROXES-22545    Major        endUser_customerSite         Q23 transparency is set to TRUE the SIP ABCF trunk group//
CROXE-15234    CROXES-19988    Major        endUser_customerSite         [Report] : Crash CPU MAIN with Backtrace + Crash Standby
                                                                         [Report] : [Related] : SEPLOS user: Impossible to retrieve
                                                                         the first call on OTC Smartphone if second calling party
CROXE-15351    CROXES-20759    Major        endUser_prebetaSystem        release the call first .
CROXE-14813    CROXE-13130     Major        software_validation          [Report] : M4: IPNOSIS traffic testing Memory usage
                                                                         [Report] : Cannot register new DECT sets, no answer on
CROXES-23034   CROXES-20848    Major        endUser_customerSite         dectinston tool
                                                                         [Report] : The incoming call from SIP Trunk transit OXE to
CROXE-14896    CROXE-13106     Major        endUser_customerSite         DPNSS Trunk fails.
                                                                         [Report] : INT_HS role status for standby INTIP3B link see
CROXE-14891    CROXE-13071     Major        endUser_customerSite         in config all
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14            TC2632en-ed.06
Copyright © ALE International 2020                                                                           page 141/143
List of all Duplicates
 ISSUE KEY       MAIN CR       PRIORITY        HOW FOUND                                      SUMMARY
                                                                    R12.3.1: Getting Error message and Numan Spvi field not
CROXES-22921   CROXE-14836     Major        validation_funcManual   updated in multitool command
CROXES-22951   CROXES-22437    Major        endUser_customerSite    CCD - main_afe KO after upgrade OXE. Catalog.cfg corrupted
                                                                    No hybrid links was up after upgrade to R12.2, need hotfix in
CROXE-14907    CROXE-12415     Minor        endUser_customerSite    R12.3 m4.30.18.h//00419680
                                                                    // Database inconsistencies of table KEYBOARD following
                                                                    migration to R12.3. Duplicate of CROXES-22954// à migration en
CROXES-23008   CROXES-22954    Critical     endUser_customerSite    R12.3
CROXES-22769   CROXES-22437    Minor        endUser_customerSite    Main_afe process can't start after OXE migration
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14          TC2632en-ed.06
Copyright © ALE International 2020                                                                         page 142/143
Submitting a Service Request
Please connect to our eService Request application.
Before submitting a Service Request, please be sure:
    The application has been certified via the AAPP if a third party application is involved.
    You have read the release notes that list new features, system requirements, restrictions, and more,
       and are available in the Technical Documentation Library.
    You have read through the related troubleshooting guides and technical bulletins available in the
       Technical Documentation Library.
    You have read through the self-service information on commonly asked support questions and known
       issues and workarounds available in the Technical Knowledge Center.
                                         - END OF DOCUMENT -
OmniPCX Enterprise - Release 12.3.1
Release Note & Installation procedure for OmniPCX Enterprise R12.3.1 Released version M4.501.14   TC2632en-ed.06
Copyright © ALE International 2020                                                                  page 143/143