ENGINE RATINGS AND FUEL CONSUMPTION
ISO STANDARD (CONTINUOUS) RATINGS FOR MODEL L5794GSI WITH ESM®
130° F (54° C) AUXILIARY WATER TEMPERATURE
180° F (82° C) JACKET WATER TEMPERATURE
Part Load Fuel Consumption
Wastegates Set For Continuous Power Rating
9000
8800 12400
8600
8400 11900
8200
11400
8000
7800 1200 RPM
10900
7600
1100 RPM
7400
10400
700 RPM 1000 RPM
7200
900 RPM
800 RPM
7000 9900
400 600 800 1000 1200 1400 1600
BHP
RPM 700 800 900 1000 1200
CONTINUOUS BHP 805 920 1035 1150 1380
OVERLOAD BHP NONE 1010 1135 1265 1515
OVERLOAD Allowed 2 Hours Per 24 Hours
Barometer Ambient Temperature
STANDARD CONDITIONS
29.54 in. Hg. (100 kPa) 77° F (25° C)
Reference S-8154-8 Ratings Standards and Adjustments to Ratings for High Altitude and
DEDUCTIONS
High Ambient Temperature Applications (or most recent version).
Dry Natural Gas – 900 Btu/ft3 (35.38 MJ/m3) SLHV; 91 WKI®
FUEL
Refer to S-7884-7 for Full Fuel Specification
EQUIPMENT Engine Equipped with Lube Oil and Cooling Water Pumps but without Radiator Fan
Turbocharged & Intercooled with 130° F (54° C) Intercooler Water
ENGINE DATA
8.25:1 Compression Ratio
NOTES:W
1. ISO Standard (continuous) power ratings conform to ISO 3046/1, latest version, with a mechanical efficiency of 90%
and auxiliary water temperature, Tcra, of 130° F (54° C) limited to ± 10° F (± 5.5° C).
2. Reference Heat Rejection and Operating Data Standard Sheet S-6124-78.
3. Engine set to an exhaust carbon monoxide concentration of 0.38% to provide stoichiometric air/fuel ratio operation at
rated speed and ISO Standard Power with spark timing as provided by the ESM®.
Page 1 of 1
ENGINE RATINGS & FUEL CONSUMPTION EN: 127970 Ref.
MODEL L5794GSI WITH ESM®
130° F (54° C) AUXILIARY WATER TEMPERATURE C
DATE: 7/03
180° F (82° C) JACKET WATER TEMPERATURE 268-10