CR 10-X Digitizer

CR 10-X Digitizer CR 10-X Digitizer

safety Why Agfa HealthCare?


Digitizer

CR 10-X
Region Regulation X-ray Laser
Agfa HealthCare is a global leader in the fast growing market of integrated IT and imaging systems, offering
Europe EN/IEC 60601-1 edition 2 Regulation: 1987 EN 60825 - 1:2001 healthcare facilities a seamless flow of information and a 360˚ view of patient care. The company has a unique,
holistic approach, enabling it to provide in-depth clinical know-how and fully integrated hospital-wide solutions.
EN/IEC 60601-1 edition 3 EN 60825 - 1:2007
These specialized solutions integrate IT and imaging systems for Radiology, Cardiology, Mammography and
EN/IEC 60601-1-2 Orthopaedics. Agfa HealthCare’s enterprise-wide IT platform integrates all administrative and clinical data
USA UL 60601-1 DHHS/FDA 21 CFR DHHS/FDA 21
within a healthcare facility and is designed to match the unique needs of specific healthcare professionals. Affordable computed radiography solution that
makes no compromises on image quality
21CFR part 820: good part 1002, subchapter B CFR parts 1040, 10
www.agfahealthcare.com
manufacturing practice for and 1040, 11
The table-top CR 10-X digitizer is based on proven Agfa
medical devices HealthCare technology, with a modular yet robust design
offering affordability without compromising on image
Canada CSA22.2 No.601.1 No.601.1.2 CSA E60825-1 (R2007)
quality. Versatile, this computed radiography (CR) digitizer
can handle general radiography, orthopaedic, chiropractic
and Full Leg/Full Spine applications. The total cost of
ownership remains low, thanks to its ease of installation,
maintenance and use, making it an affordable way to move
from analog to digital. With the CR 10-X, small hospitals and
private practices can take advantage of the convenient and

The affordable, compact CR 10-X digitizer fast workflow offered by digital radiography.
is designed as an ideal solution for
small practices, offering a cost-effective
entry into digital Radiography without
compromising on image quality.

• Affordable computed radiography solution that


makes no compromises on image quality
• Convenient and fast workflow
• Robust yet easy to install and maintain
• Fits in small spaces and is suited for mobile
applications
• Networking capabilities deliver seamless
integration
Agfa and the Agfa rhombus are trademarks of Agfa-Gevaert N.V., Belgium, or its affiliates. All other © 2012 Agfa HealthCare NV
trademarks are held by their respective owners and are used in an editorial fashion with no intention
All rights reserved
of infringement. The data in this publication are for illustration purposes only and do not necessarily
represent standards or specifications, which must be met by Agfa HealthCare. All information contained Printed in Belgium
herein is intended for guidance purposes only, and characteristics of the products and services described in Published by Agfa HealthCare NV
this publication can be changed at any time without notice. Products and services may not be available for
B-2640 Mortsel - Belgium
your local area. Please contact your local sales representative at agfa.com for availability information. Agfa
HealthCare diligently strives to provide as accurate information as possible, but shall not be responsible 5TM91 GB 00201202
for any typographical error.

5
CR 10-X Digitizer CR 10-X Digitizer CR 10-X Digitizer

Convenient and fast workflow

The CR 10-X works in conjunction with NX, Agfa


Bar code
In order to guarantee highest image quality, each image
plate contains a bar code which contains all plate specific
technical
SPECIFICATIONS
HealthCare’s image identification and quality control tool, data and expiration date of the plate.
for a highly efficient and optimized radiology workflow.
GENERAL Environmental conditions
It comes with Agfa HealthCare’s gold-standard MUSICA2
Digitizer type • In line with: IEC 721-3-3 (1997): class 3K2, with the
software, which automatically handles all calibration and
• Single cassette feed following extension:
image processing, independently of body part and dose,
• Throughput: 35 x 43 cm (14 x 17”) = approx. • Temperature: 15 - 35° C
optimizing the final image quality without the need for
34 plates/hour
any human intervention or special training. The CR 10-X
Environmental effects
reads imaging plates at the high resolution of 10 pixels/mm
Display • Noise level: max. 65 dB (A)
(100 µm pixel pitch). The dedicated cassettes are inserted
• LED Status Indicator • Heat dissipation: standby 30 W, max. 85 W
horizontally, which prevents dust and dirt from being
• Status and error messages on external PC monitor
introduced during normal operation.
Mobile use
Fits in small spaces and is suited for mobile • In line with IEC721-3-3 (1997): with following
General radiography & Full Leg/Full Spine: imaging plate and cassette Greyscale resolution
applications restrictions:
• Data acquisition: 20 bits/pixel
Robust yet easy to install and maintain • Temperature: +15° C to +35° C
• Output to processor: 16 bits/pixel square root
With its table-top size, the CR 10-X digitizer can be placed
compressed • Humidity: 15 - 75 % RH (non-condensing)
Installing the CR 10-X is fast and easy. Special LED easily at any location, no matter how small, and was
CASSETTE SIZES • During transport: in line with IEC721-3-5: 5K1
technology in the erasure unit means low power designed with ease of use in mind. The CR 10-X can also be
Dimensions and weight and 5M3
consumption. With its ‘one screwdriver’ concept and fitted into cars, vans, trucks and other mobile facilities, for
Cassette Sizes Spatial Resolution • W x D x H: 580 x 700 x 471 mm
modular, component-based design, maintenance is faster, mobile applications.
• Depth without cassette unit and extension: 380 mm Transport
easier and more cost-effective, as well. Consequently, set
• Weight: 29 kg • In line with: IEC 721-3-2 (1997): class 2K2, with the
up costs are lower and installation simpler. CR MD1.0 General 35 x 43 cm (14 x 17”) 10 pixels/mm
following restrictions:
Networking capabilities deliver seamless • -25 to +55° C (-4 to 131° F)
Power
integration
• Autoranging external power supply (24 V output)
• Input: Storage
The CR 10-X is fully DICOM-compliant, to easily integrate
• 100 V - 240 V • Packed device shall withstand the following
with other solution elements; we recommend combining
• < 2 A mechanical conditions: IEC 721-3-1: class 1M2 and
it with Agfa HealthCare’s SE software suite for a complete
• 50/60 Hz IEC 721-3-2(1993): class 2M3; including
softcopy solution, or with the DRYSTAR 5302 imager for a
• Fuse: Europe max 16 A; USA max 15 A sea transport.
hardcopy solution.
• In line with IEC721-3-1: class 1K4
Minimum requirements
• CR MD1.0 General Cassette SAFETY
• CR MD1.0 General Plate (expires after 5 years) Approvals
• NX Workstation • CE, cNRTLus

2 3 4
CR 10-X Digitizer CR 10-X Digitizer CR 10-X Digitizer

Convenient and fast workflow

The CR 10-X works in conjunction with NX, Agfa


Bar code
In order to guarantee highest image quality, each image
plate contains a bar code which contains all plate specific
technical
SPECIFICATIONS
HealthCare’s image identification and quality control tool, data and expiration date of the plate.
for a highly efficient and optimized radiology workflow.
GENERAL Environmental conditions
It comes with Agfa HealthCare’s gold-standard MUSICA2
Digitizer type • In line with: IEC 721-3-3 (1997): class 3K2, with the
software, which automatically handles all calibration and
• Single cassette feed following extension:
image processing, independently of body part and dose,
• Throughput: 35 x 43 cm (14 x 17”) = approx. • Temperature: 15 - 35° C
optimizing the final image quality without the need for
34 plates/hour
any human intervention or special training. The CR 10-X
Environmental effects
reads imaging plates at the high resolution of 10 pixels/mm
Display • Noise level: max. 65 dB (A)
(100 µm pixel pitch). The dedicated cassettes are inserted
• LED Status Indicator • Heat dissipation: standby 30 W, max. 85 W
horizontally, which prevents dust and dirt from being
• Status and error messages on external PC monitor
introduced during normal operation.
Mobile use
Fits in small spaces and is suited for mobile • In line with IEC721-3-3 (1997): with following
General radiography & Full Leg/Full Spine: imaging plate and cassette Greyscale resolution
applications restrictions:
• Data acquisition: 20 bits/pixel
Robust yet easy to install and maintain • Temperature: +15° C to +35° C
• Output to processor: 16 bits/pixel square root
With its table-top size, the CR 10-X digitizer can be placed
compressed • Humidity: 15 - 75 % RH (non-condensing)
Installing the CR 10-X is fast and easy. Special LED easily at any location, no matter how small, and was
CASSETTE SIZES • During transport: in line with IEC721-3-5: 5K1
technology in the erasure unit means low power designed with ease of use in mind. The CR 10-X can also be
Dimensions and weight and 5M3
consumption. With its ‘one screwdriver’ concept and fitted into cars, vans, trucks and other mobile facilities, for
Cassette Sizes Spatial Resolution • W x D x H: 580 x 700 x 471 mm
modular, component-based design, maintenance is faster, mobile applications.
• Depth without cassette unit and extension: 380 mm Transport
easier and more cost-effective, as well. Consequently, set
• Weight: 29 kg • In line with: IEC 721-3-2 (1997): class 2K2, with the
up costs are lower and installation simpler. CR MD1.0 General 35 x 43 cm (14 x 17”) 10 pixels/mm
following restrictions:
Networking capabilities deliver seamless • -25 to +55° C (-4 to 131° F)
Power
integration
• Autoranging external power supply (24 V output)
• Input: Storage
The CR 10-X is fully DICOM-compliant, to easily integrate
• 100 V - 240 V • Packed device shall withstand the following
with other solution elements; we recommend combining
• < 2 A mechanical conditions: IEC 721-3-1: class 1M2 and
it with Agfa HealthCare’s SE software suite for a complete
• 50/60 Hz IEC 721-3-2(1993): class 2M3; including
softcopy solution, or with the DRYSTAR 5302 imager for a
• Fuse: Europe max 16 A; USA max 15 A sea transport.
hardcopy solution.
• In line with IEC721-3-1: class 1K4
Minimum requirements
• CR MD1.0 General Cassette SAFETY
• CR MD1.0 General Plate (expires after 5 years) Approvals
• NX Workstation • CE, cNRTLus

2 3 4
CR 10-X Digitizer CR 10-X Digitizer CR 10-X Digitizer

Convenient and fast workflow

The CR 10-X works in conjunction with NX, Agfa


Bar code
In order to guarantee highest image quality, each image
plate contains a bar code which contains all plate specific
technical
SPECIFICATIONS
HealthCare’s image identification and quality control tool, data and expiration date of the plate.
for a highly efficient and optimized radiology workflow.
GENERAL Environmental conditions
It comes with Agfa HealthCare’s gold-standard MUSICA2
Digitizer type • In line with: IEC 721-3-3 (1997): class 3K2, with the
software, which automatically handles all calibration and
• Single cassette feed following extension:
image processing, independently of body part and dose,
• Throughput: 35 x 43 cm (14 x 17”) = approx. • Temperature: 15 - 35° C
optimizing the final image quality without the need for
34 plates/hour
any human intervention or special training. The CR 10-X
Environmental effects
reads imaging plates at the high resolution of 10 pixels/mm
Display • Noise level: max. 65 dB (A)
(100 µm pixel pitch). The dedicated cassettes are inserted
• LED Status Indicator • Heat dissipation: standby 30 W, max. 85 W
horizontally, which prevents dust and dirt from being
• Status and error messages on external PC monitor
introduced during normal operation.
Mobile use
Fits in small spaces and is suited for mobile • In line with IEC721-3-3 (1997): with following
General radiography & Full Leg/Full Spine: imaging plate and cassette Greyscale resolution
applications restrictions:
• Data acquisition: 20 bits/pixel
Robust yet easy to install and maintain • Temperature: +15° C to +35° C
• Output to processor: 16 bits/pixel square root
With its table-top size, the CR 10-X digitizer can be placed
compressed • Humidity: 15 - 75 % RH (non-condensing)
Installing the CR 10-X is fast and easy. Special LED easily at any location, no matter how small, and was
CASSETTE SIZES • During transport: in line with IEC721-3-5: 5K1
technology in the erasure unit means low power designed with ease of use in mind. The CR 10-X can also be
Dimensions and weight and 5M3
consumption. With its ‘one screwdriver’ concept and fitted into cars, vans, trucks and other mobile facilities, for
Cassette Sizes Spatial Resolution • W x D x H: 580 x 700 x 471 mm
modular, component-based design, maintenance is faster, mobile applications.
• Depth without cassette unit and extension: 380 mm Transport
easier and more cost-effective, as well. Consequently, set
• Weight: 29 kg • In line with: IEC 721-3-2 (1997): class 2K2, with the
up costs are lower and installation simpler. CR MD1.0 General 35 x 43 cm (14 x 17”) 10 pixels/mm
following restrictions:
Networking capabilities deliver seamless • -25 to +55° C (-4 to 131° F)
Power
integration
• Autoranging external power supply (24 V output)
• Input: Storage
The CR 10-X is fully DICOM-compliant, to easily integrate
• 100 V - 240 V • Packed device shall withstand the following
with other solution elements; we recommend combining
• < 2 A mechanical conditions: IEC 721-3-1: class 1M2 and
it with Agfa HealthCare’s SE software suite for a complete
• 50/60 Hz IEC 721-3-2(1993): class 2M3; including
softcopy solution, or with the DRYSTAR 5302 imager for a
• Fuse: Europe max 16 A; USA max 15 A sea transport.
hardcopy solution.
• In line with IEC721-3-1: class 1K4
Minimum requirements
• CR MD1.0 General Cassette SAFETY
• CR MD1.0 General Plate (expires after 5 years) Approvals
• NX Workstation • CE, cNRTLus

2 3 4
CR 10-X Digitizer CR 10-X Digitizer CR 10-X Digitizer

safety Why Agfa HealthCare?


Digitizer

CR 10-X
Region Regulation X-ray Laser
Agfa HealthCare is a global leader in the fast growing market of integrated IT and imaging systems, offering
Europe EN/IEC 60601-1 edition 2 Regulation: 1987 EN 60825 - 1:2001 healthcare facilities a seamless flow of information and a 360˚ view of patient care. The company has a unique,
holistic approach, enabling it to provide in-depth clinical know-how and fully integrated hospital-wide solutions.
EN/IEC 60601-1 edition 3 EN 60825 - 1:2007
These specialized solutions integrate IT and imaging systems for Radiology, Cardiology, Mammography and
EN/IEC 60601-1-2 Orthopaedics. Agfa HealthCare’s enterprise-wide IT platform integrates all administrative and clinical data
USA UL 60601-1 DHHS/FDA 21 CFR DHHS/FDA 21
within a healthcare facility and is designed to match the unique needs of specific healthcare professionals. Affordable computed radiography solution that
makes no compromises on image quality
21CFR part 820: good part 1002, subchapter B CFR parts 1040, 10
www.agfahealthcare.com
manufacturing practice for and 1040, 11
The table-top CR 10-X digitizer is based on proven Agfa
medical devices HealthCare technology, with a modular yet robust design
offering affordability without compromising on image
Canada CSA22.2 No.601.1 No.601.1.2 CSA E60825-1 (R2007)
quality. Versatile, this computed radiography (CR) digitizer
can handle general radiography, orthopaedic, chiropractic
and Full Leg/Full Spine applications. The total cost of
ownership remains low, thanks to its ease of installation,
maintenance and use, making it an affordable way to move
from analog to digital. With the CR 10-X, small hospitals and
private practices can take advantage of the convenient and

The affordable, compact CR 10-X digitizer fast workflow offered by digital radiography.
is designed as an ideal solution for
small practices, offering a cost-effective
entry into digital Radiography without
compromising on image quality.

• Affordable computed radiography solution that


makes no compromises on image quality
• Convenient and fast workflow
• Robust yet easy to install and maintain
• Fits in small spaces and is suited for mobile
applications
• Networking capabilities deliver seamless
integration
Agfa and the Agfa rhombus are trademarks of Agfa-Gevaert N.V., Belgium, or its affiliates. All other © 2012 Agfa HealthCare NV
trademarks are held by their respective owners and are used in an editorial fashion with no intention
All rights reserved
of infringement. The data in this publication are for illustration purposes only and do not necessarily
represent standards or specifications, which must be met by Agfa HealthCare. All information contained Printed in Belgium
herein is intended for guidance purposes only, and characteristics of the products and services described in Published by Agfa HealthCare NV
this publication can be changed at any time without notice. Products and services may not be available for
B-2640 Mortsel - Belgium
your local area. Please contact your local sales representative at agfa.com for availability information. Agfa
HealthCare diligently strives to provide as accurate information as possible, but shall not be responsible 5TM91 GB 00201202
for any typographical error.

5
CR 10-X Digitizer CR 10-X Digitizer CR 10-X Digitizer

safety Why Agfa HealthCare?


Digitizer

CR 10-X
Region Regulation X-ray Laser
Agfa HealthCare is a global leader in the fast growing market of integrated IT and imaging systems, offering
Europe EN/IEC 60601-1 edition 2 Regulation: 1987 EN 60825 - 1:2001 healthcare facilities a seamless flow of information and a 360˚ view of patient care. The company has a unique,
holistic approach, enabling it to provide in-depth clinical know-how and fully integrated hospital-wide solutions.
EN/IEC 60601-1 edition 3 EN 60825 - 1:2007
These specialized solutions integrate IT and imaging systems for Radiology, Cardiology, Mammography and
EN/IEC 60601-1-2 Orthopaedics. Agfa HealthCare’s enterprise-wide IT platform integrates all administrative and clinical data
USA UL 60601-1 DHHS/FDA 21 CFR DHHS/FDA 21
within a healthcare facility and is designed to match the unique needs of specific healthcare professionals. Affordable computed radiography solution that
makes no compromises on image quality
21CFR part 820: good part 1002, subchapter B CFR parts 1040, 10
www.agfahealthcare.com
manufacturing practice for and 1040, 11
The table-top CR 10-X digitizer is based on proven Agfa
medical devices HealthCare technology, with a modular yet robust design
offering affordability without compromising on image
Canada CSA22.2 No.601.1 No.601.1.2 CSA E60825-1 (R2007)
quality. Versatile, this computed radiography (CR) digitizer
can handle general radiography, orthopaedic, chiropractic
and Full Leg/Full Spine applications. The total cost of
ownership remains low, thanks to its ease of installation,
maintenance and use, making it an affordable way to move
from analog to digital. With the CR 10-X, small hospitals and
private practices can take advantage of the convenient and

The affordable, compact CR 10-X digitizer fast workflow offered by digital radiography.
is designed as an ideal solution for
small practices, offering a cost-effective
entry into digital Radiography without
compromising on image quality.

• Affordable computed radiography solution that


makes no compromises on image quality
• Convenient and fast workflow
• Robust yet easy to install and maintain
• Fits in small spaces and is suited for mobile
applications
• Networking capabilities deliver seamless
integration
Agfa and the Agfa rhombus are trademarks of Agfa-Gevaert N.V., Belgium, or its affiliates. All other © 2012 Agfa HealthCare NV
trademarks are held by their respective owners and are used in an editorial fashion with no intention
All rights reserved
of infringement. The data in this publication are for illustration purposes only and do not necessarily
represent standards or specifications, which must be met by Agfa HealthCare. All information contained Printed in Belgium
herein is intended for guidance purposes only, and characteristics of the products and services described in Published by Agfa HealthCare NV
this publication can be changed at any time without notice. Products and services may not be available for
B-2640 Mortsel - Belgium
your local area. Please contact your local sales representative at agfa.com for availability information. Agfa
HealthCare diligently strives to provide as accurate information as possible, but shall not be responsible 5TM91 GB 00201202
for any typographical error.