1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A
4

03

5
5A

B
A

DETAIL C
POS 4 DETAIL

1 3

E
P
5A

O
L
S
C
C

ƒ

1%
2
5A

E 3

P
O
L 2

S POS 3 DETAIL

283.5° 1% 4



D
2 D

C
3

DETAIL B
C
2
102.4°
E
E

POS 2 DETAIL

E
P
O

5A 03

L
S

ƒ
1%



5 5

F
F

A
5 5

POS 1 DETAIL

5 5A 5 5

G
193° G

5 5

5 5

THIS PORTION TO BE
5 5A 5A

JOGGLED DOWN TO SHAPE TO HAVE


H SOUND CONTACT BETWEEN PLATES
H

POS 5 DETAIL POS 5A DETAIL

Industrial Solutions
Acceptance Code
1 1 5 5A 5A

1 APPROVED

with minor comment

thyssenkrupp
This approval does not release the vendor / supplier
from full responsibility for his design and fabrication.
1 % SLOPE
5

11-12-2019 [email protected]

Date Name AKA/ZSS


J
J

(MAIN) FIRST BOTTOM & ANNULAR PLATE

DETAIL A

(REFER PLAN VIEW FOR SLOPE DETAIL)

Plate cutting layout is vendors


responsibility

S
PDE-EQP-G000-DZ-00033-0020
EF/2018-036-3071T001A/BoM000 BOM List

7
R
PDE-EQP-G000-DZ-00033-0019
EF/2018-036-3071T001A/017
Insulation Details

6
1

P
PDE-EQP-G000-DZ-00033-0018
EF/2018-036-3071T001A/016
Name plate

(113 m2)

K
O
PDE-EQP-G000-DZ-00033-0017
EF/2018-036-3071T001A/015 Internals, clips, earthing lug and others

N
PDE-EQP-G000-DZ-00033-0016
EF/2018-036-3071T001A/014 Handrailing & platform details

5
M
PDE-EQP-G000-DZ-00033-0015
EF/2018-036-3071T001A/013 Ladder (stairway) details

L
PDE-EQP-G000-DZ-00033-0014
EF/2018-036-3071T001A/012 Anchorage details

K
PDE-EQP-G000-DZ-00033-0013
EF/2018-036-3071T001A/011 Roof manhole

J
PDE-EQP-G000-DZ-00033-0012
EF/2018-036-3071T001A/010 Roof nozzles

I
PDE-EQP-G000-DZ-00033-0011
EF/2018-036-3071T001A/009 Shell Manhole

H
PDE-EQP-G000-DZ-00033-0010
EF/2018-036-3071T001A/008 Shell Nozzles

L
L

GAP TO BE FILLED BY WELD


G
PDE-EQP-G000-DZ-00033-0009
EF/2018-036-3071T001A/006 Roof (Cone) structure details

(NO SCALE-TYPICAL)

(REFER MESH DETAIL FOR ORIENTATION)


F
PDE-EQP-G000-DZ-00033-0008
EF/2018-036-3071T001A/005 Roof (Cone) plate details

CERAMIC BACKING

E
PDE-EQP-G000-DZ-00033-0007
EF/2018-036-3071T001A/004 Shell Plate Details

D
PDE-EQP-G000-DZ-00033-0006
EF/2018-036-3071T001A/003
Bottom Plate (double) layout

C
PDE-EQP-G000-DZ-00033-0005
EF/2018-036-3071T001A/002
Annular & Bottom Plate (main) layout
M

B
PDE-EQP-G000-DZ-00033-0004
EF/2018-036-3071T001A/001 Nozzle Orientation

A
PDE-EQP-G000-DZ-00033-0003
EF/2018-036-3071T001A/000 General Arrangement Dwg

M
Pos tkIS - Dwg Number
Efor - Dwg Number Drawing Name

REFERENCE DRAWINGS

1 2 3 4 5 6 7 8 9 10 11 12 13 50 mm 14 Copyright reserved 16