Telpro Tubular Anodes Data Sheet: Manufacturers of Mmo and Platinized Titanium Electrodes
Telpro Tubular Anodes Data Sheet: Manufacturers of Mmo and Platinized Titanium Electrodes
PLATINIZED TITANIUM ELECTRODES
TELPRO TUBULAR ANODES DATA SHEET
Titanium Electrode Products Companies, “TELPRO,” are
manufacturers of mixed metal oxide anodes for cathodic
protection.
TELPRO Tubular Anodes are manufactured using
titanium, which meets ASTM B338 Grade 1 or Grade 2
standards, which has been coated with TELPRO Mixed
Metal Oxide coating.
TELPRO MMO coating consists of IrO2/Ta2O5 and is
suitable for use in all cathodic protection applications.
Because mixed metal oxide anodes have an extremely low
consumption rate, the titanium substrate remains constant
throughout the design life of the anode.
Based upon accelerated life testing, conducted by an
APPLICATIONS independent laboratory, TELPRO MMO coating has been
CANISTERED ANODES proven to be equivalent or superior to other mixed metal
ABOVE GROUND STORAGE TANKS oxide coatings which are currently being used; a copy of
UNDERGROUND STORAGE TANKS this test report is available upon request.
WATER STORAGE TANKS
HORIZONTAL GROUNDBEDS
TUBULAR AND SHEET PILES
VERTICAL GROUNDBEDS
DEEP WELL ANODE GROUNDBEDS
Strict quality control procedures are followed throughout the entire coating process, to guarantee proper coating
adhesion and loading. Also, TELPRO products are tested using an X‐Ray Fluorescence Spectrometer, to ensure
production of the highest quality product, which is fundamental in every step of the manufacturing process.
PERFORMANCE DATA AND RATINGS
COKE, SOIL AND FRESH WATER CURRENT OUTPUT DESIGN LIFE
3/4" x 48" (19mm x 1,220mm) 7 Amps 20 years
1" x 19.7" (25mm x 500mm) 4 Amps 20 years
1" x 39.4" (25mm x 1,000mm) 8 Amps 20 years
1" x 48" (25mm x 1,220mm) 3.5 Amps * 20 years
1" x 60" (25mm x 1,500mm) 4.5 Amps * 20 years
1.25" x 48" (32mm x 1,220mm) 12 Amps 20 years
* Current outputs are de‐rated for use in metallurgical coke breeze ‐ 50Am2
USA OFFICE : PHONE 281 498 4727 FAX 281 498 4728 TOLL FREE 877 483 5776
UK OFFICE : PHONE 44 1453 845 718 FAX 44 1453 845 719
WEB : WWW.TELPROCOMPANIES.COM
EMAIL : [email protected] / [email protected]
MANUFACTURERS OF MMO AND
PLATINIZED TITANIUM ELECTRODES
TELPRO TUBULAR ANODES DATA SHEET
SEAWATER CURRENT OUTPUT DESIGN LIFE
3/4" x 48" (19mm x 1,220mm) 45 Amps 20 years
1" x 19.7" (25mm x 500mm) 25 Amps 20 years
1" x 39.4" (25mm x 1,000mm) 50 Amps 20 years
1.25" x 48" (32mm x 1,220mm) 75 Amps 20 years
ENVIRONMENT MAX CURRENT DENSITY LIFETIME
2 2
CARBONACEOUS BACKFILL 4.6A/ft (50A/m ) 20 years
2 2
CALCINED PETROLEUM BACKFILL 9.3A/ft (100A/m ) 20 years
FRESHWATER 9.3A/ft2 (100A/m2) 20 years
2 2
BRACKISH WATER 9.3‐27.8A/ft (100‐300A/m ) 20 years
2 2
SEAWATER 55.8A/ft (600A/m ) 20 years
Lifetimes stated are nominal, we can supply Amps / life different to stated standards on request
TYPICAL APPLICATIONS FOR TUBULAR ANODES
HORIZONTAL GROUNDBEDS
PROTECTION OF CROSS COUNTRY PIPELINES
ANODES TYPICALLY INSTALLED IN A TRENCH WITH
COKE BACKFILL
IDEAL FOR AREAS OF LOW RESISTIVITY / NO ACCESS /
R.O.W. ISSUES
DEEPWELL GROUNDBEDS
PROTECTION OF PIPELINES / WELL CASINGS
ANODES INSTALLED IN COKE BREEZE COLUMN OR
BELOW WATER TABLE LEVEL
USED IN AREAS OF HIGH SURFACE RESISTIVITY
AND/ OR ACCESS / R.O.W. LIMITATIONS
ACTIVE WELL AREA LINED WITH PERFORATED CASING