0% found this document useful (0 votes)
70 views1 page

Strongpost W-Beam Double-Sided Guardrail (Sgm04B) : Open Source - No Specific Supplier TL3. NCHRP-350 TL-3

The document describes a legacy Strong Post Timber W-Beam median barrier system that was generally used where a maximum dynamic deflection of 600 mm or less was acceptable. It is a non-proprietary system that uses timber posts with wooden blockouts and was tested to Test Level 3 standards. The barrier is not recommended for new installations and existing systems may only be repaired or maintained until replacement.

Uploaded by

jcvalencia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views1 page

Strongpost W-Beam Double-Sided Guardrail (Sgm04B) : Open Source - No Specific Supplier TL3. NCHRP-350 TL-3

The document describes a legacy Strong Post Timber W-Beam median barrier system that was generally used where a maximum dynamic deflection of 600 mm or less was acceptable. It is a non-proprietary system that uses timber posts with wooden blockouts and was tested to Test Level 3 standards. The barrier is not recommended for new installations and existing systems may only be repaired or maintained until replacement.

Uploaded by

jcvalencia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NZTA M23A 2017 | 8

STRONGPOST W-BEAM DOUBLE-SIDED GUARDRAIL (SGM04B)

SUMMARY

SUPPLIER: Open source - no specific supplier

TEST LEVEL / CONDITIONS: TL3. NCHRP-350 TL-3

FOR USE WITH W-Beam barriers should be anchored and terminated using a suitable end treatment.

STATUS Legacy System, repair use only, not for new State Highway installations

Strong Post Timber W-Beam median barriers were generally used in locations where a maximum dynamic deflection of 600 mm or less was
acceptable. It is a public domain (non-proprietary) system.
The SGM04b uses timber posts with wooden blockouts and was a Test Level 3 barrier.
Strong Post Timber W-Beam median barrier is a legacy system and may not be installed on new State Highway projects. Existing installations
may be repaired/maintained until replacement with a higher performing barrier system is viable or necessary.

TECHNICAL INFORMATION

DIMENSIONS 1905mm post spacing


660mm < Height < 762mm

MINIMUM LENGTH Unit length: 3810 mm

DEFLECTION 600mm to 1200mm

OTHER RESTRICTIONS / „„ W-Beam barriers should be anchored and terminated using a suitable end treatment.
CONSIDERATIONS „„ 2 x 16d nails used on each side to prevent block rotation.

COMMON FAULTS / OTHER CONSIDERATIONS


•• W-Beam guardrail element may be considered serviceable after damage to a single rib, but non serviceable if there is damage to 2 ribs
within 2m.
•• Legacy system, not for new State Highway installations.

FURTHER READING / REFERENCES


•• Refer to AASHTO 2-Space W-Beam Guardrail (RWM02a-b) for details of W-Beam element.

You might also like