250-KYOWA SF Catalog

This document provides an overview of strain gage products offered by Kyowa Measuring Instruments. It lists various types of strain gages including general-purpose foil strain gages, waterproof foil strain gages, weldable waterproof foil strain gages, strain gages for concrete, foil strain gages for composite materials, foil strain gages for printed boards, semiconductor strain gages, high-temperature foil strain gages, and foil strain gages. For each type, it provides details on features such as gage length, pattern, operating temperature range, and resistance.

Uploaded by

adi nugroho
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views23 pages

250-KYOWA SF Catalog

This document provides an overview of strain gage products offered by Kyowa Measuring Instruments. It lists various types of strain gages including general-purpose foil strain gages, waterproof foil strain gages, weldable waterproof foil strain gages, strain gages for concrete, foil strain gages for composite materials, foil strain gages for printed boards, semiconductor strain gages, high-temperature foil strain gages, and foil strain gages. For each type, it provides details on features such as gage length, pattern, operating temperature range, and resistance.

Uploaded by

adi nugroho
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 23

KYOWA

MEASURING
INSTRUMENTS
2005∼2006

★Strain Gages
★Load Cells
★Pressure Transducers
★Acceleration Transducers
★Torque Transducers
★Displacement Transducers
★Dynamic Strain Amplifiers
★Data Loggers
★Data Analyzers
★Instrumentation Amplifiers & Related Instruments
★Automotive Test Equipment
★Traffic System    
★Civil Engineering/Construction Instruments

        
Strain Gages

General-Purpose Foil Strain Gages Waterproof Foil Strain Gages

● Superior flexibility, and outstanding moisture proofness requiring no ● Usable either outdoors or underwater (100
coating treatment unless splashed directly with water. hours or more under 10MPa in water)
● All models are equipped with leadwire cable. ● Gage length: 2, 5 mm
● Improved characteristics ● Gage pattern: Uniaxial, biaxial 0°/90°, triaxial
Operating temperature range: –196 to 120°C (when bonded with CC- 0°/90°/45° (triaxial is available only for KFW)
33A), –196 to 150°C (when bonded with PC-6) ● Applicable linear expansion coefficient:
High performance: Self-temperature-compensation of ±1.0 µm/m/°C at 11, 16, 23 x10–6/°C
normal temperatures and capability of measurement up to strain limit of ● Resistance: 120, 350 Ω (KFWS: 120 Ω only)
5% (uniaxial)
● Gage length: 0.2, 0.3, 1, 2, 3, 4, 5, 6, 10, 20, 30 mm
● Gage pattern: Uniaxial, biaxial, triaxial, quadraxial, uniaxial 5-element, Weldable Waterproof Foil Strain Gages
biaxial 5-element
● Applicable linear expansion coefficient: 5, 11, 16, 23, 27 x10–6/°C
● Leadwire cable: Polyester-coated copper wires (2 to 100 cm), vinyl- ● Available in 2 types: Uniaxial 1-element G10 and full-bridge G14S
coated cable (15 cm to 30 m), middle temperature cable (15 cm to 30 m) ● Welding type requires no coating treatment.
● Applicable adhesive: Cyanoacrylate CC-33A ● Flange size: 5 x 21 mm, t = 0.1 mm
● Applications: General stress measurement, stress analysis, torque ● Applicable linear expansion coefficient: 11 x10–6/°C
measurement, fine wire, shearing stress, concentrated stress ● Operating temperature range: –20 to 100°C
(uniaxial/biaxial 5-element)
● Resistance: 60, 120, 350, 500, 1000 Ω

Strain Gages for Concrete


Uniaxial Uniaxial with 2-wire cable Uniaxial 5-element

Wire Gages (KC)


● Gage length: 60, 70, 80, 120 mm
● Gage pattern: Uniaxial
Uniaxial for fine wire Foil Gages (KFG)
Uniaxial for shearing stress
● Gage Length: 10, 20, 30 mm
● Gage pattern: Uniaxial,
biaxial 0°/90°, triaxial 0°/90°/45°
(Biaxial and triaxial are available only with a gage length of 10 mm.)
Biaxial 5-element ★ Concrete-embedded gages (KM, KMC) are also available.

Biaxial 0°/90° Biaxial for torque Foil Strain Gages for Composite Materials

● Suitable for strain measurement of composite


materials such as CFRP and GFRP
● Gage length: 2, 5 mm
Triaxial 0°/120°/120° ● Applicable linear expansion coefficient: 1, 3, 6, 9
x10–6/°C
Triaxial 0°/90°/45° Triaxial 0°/90°/45° with 3-leadwire cables ● Gage pattern: Uniaxial, triaxial 0°/90°/45°
● Operating temperature range: –55 to 200°C
(adhesive: EP-34B)
● Resistance: 120, 350 Ω
★ KFP gages for plastics such as acryl are also
available.
Biaxial 0°/90° Triaxial 0°/90°/45°
plane arrangement plane arrangement Quadraxial 0°/30°/90°/150°
Foil Strain Gages for Printed Boards
Foil Strain Gages with Temperature Sensor ● Ultra-small gage base enables bonding to mounted components and
narrow space on printed boards (uniaxial: 1.2 x 1.1 mm, biaxial and
triaxial: 2.5 x 2.5 mm)
● Foil strain gage and T-type thermocouple are integrated. ● Gage length: 0.2, 1 mm
● Suitable for strain measurement in environment with varying or gradient ● Applicable linear expansion coefficient: 13 x10–6/°C
temperature. (meeting that of printed boards)
● Thermally-induced apparent strain is compensated with high precision. ● Self-temperature-compensation range: –30 to120°C,
● Gage length: 2, 5 mm applicable to thermal cycling tests 8-times
● Gage pattern: Uniaxial only ● Gage pattern: Uniaxial, biaxial 0°/90°, triaxial 0°/90°/45° enlarged view
● Applicable linear expansion coefficient: 11, 16, 23, 27 x10–6/°C
● Resistance: 120 Ω
● Operating temperature range: –10 to 120°C Semiconductor Strain Gages
● Leadwires 1 m long
● Semiconductor used for the resistive element ensures several 10
times higher sensitivity than foil strain gages.
● Gage length: 1, 2, 3, 4, 6, 7, 9 mm
● Gage pattern: Uniaxial, biaxial 0°/90°,
uniaxial 2-element
● Applicable linear expansion coefficient: 11, 16 x10–6/°C
● Semiconductor gages with no gage base are also available.
Foil Strain Gages
High-Temperature Foil Strain Gages
● Polyimde base makes KFR gages usable at –196 to 150°C (adhesive: PC-6).
● Gage length: 0.15, 0.2, 0.5, 1, 2, 5 mm
● Gage pattern: Uniaxial, triaxial 0°/90°/45°, uniaxial 5-element ● Operating temperature range: –196 to 300°C (adhesive: PI-32)
● Applicable linear expansion coefficient: 11, 16, 23 x10–6/°C ● Gage length: 2, 5 mm
● Resistance: 120, 350 Ω ● Gage pattern: Uniaxial, biaxial 0°/90°, triaxial 0°/90°/45°
● Applicable linear expansion coefficient: 11, 16, 23 x10–6/°C
● Resistance: 120, 350 Ω

2
Strain Gages

Encapsulated High-Temperature Strain Gages Ultrahigh-Elongation Wire Strain Gages

● Designed to be spot-welded to measuring objects ● Enabling measurement of plastic strain of 4 to 20%


● Maximum operating temperature ● Gage length: 6 mm
KHCX: 950°C KHCD: 800°C (dynamic strain) KHCS: 750°C ● Gage pattern: Uniaxial
KHCM: 650°C KHC: 550°C ● Operating temperature range:
● Gage length: 5 mm (KHC, KHCD), 10 mm (KHCX, KHCS, KHCM, –10 to 80°C (adhesives: CC-36)
KHC), 20 mm (KHC)
● Material: Inconel 600 except for KHC made of SUS 321
● Gage pattern: 2-element temperature-compensation type except for
1-element KHCD Foil Strain Gages with Protector
● Applicable linear expansion coefficient:
11 x10–6/°C (all models),
13 x10–6/°C (KHCX, KHCS, KHCM) ● Suitable for weighing tanks and hoppers and for measuring tare
16 x10–6/°C (KHCS, KHCM, KHC) weight of tracks
● Mounted to measuring objects with the adhesive and stud bolts
● Moisture and waterproofed
● Gage length: 2, 5 mm
● Resistance: 350 Ω
● Gage pattern: Uniaxial, biaxial 0°/90°, triaxial 0°/90°/45°, bridge for
bending or shearing stress measurement)
● With vinyl-coated shield cable 10 m long
High-Temperature Foil Strain Gages

● Operating temperature range: –196 to 250°C (adhesives: PC-6, PI-32)


● Gage length: 0.2, 0.5, 1, 2, 5 mm
● Gage pattern: Uniaxial, triaxial 0°/90°/45°
● Applicable linear expansion coefficient: 11, 16, 23 x10–6/°C
● Resistance: 120, 350 Ω

High-Temperature Foil Strain Gages


Gages for Residual Stress Measurement
● Metal base enables easy bonding of the 350 Ω KH gage with the
small-sized spot welder. ● Available in 2 types: Model equipped with a terminal for easy
● Operating temperature range: –50 to 350°C
connection/disconnection of leadwires and model for boring method
● Gage length: 5 mm
● Gage pattern and gage length
● Applicable linear expansion coefficient: 11, 16 x10–6/°C
Model with terminal: Uniaxial, biaxial, triaxial; 1, 2 mm
Model for boring method: Triaxial 0°/135°/90°; 1.5, 3 mm
● Applicable linear expansion coefficient: 11, 16, 23, 27 x10–6/°C (27 is
available only for boring method.)

Low-Temperature Foil Strain Gages

● Usable at a temperature as low as –269°C if bonded with PC-6


adhesive or –196°C if bonded with CC-33A or UC-26 adhesive Gages for Bolt Axial Tension Measurement
● Gage length: 0.2, 0.5, 1, 2, 5, 30 mm
● Applicable linear expansion coefficient: 5, 11, 16, 23 x10–6/°C (5 is
available only for a gage length of 30 mm)
● Resistance: 120, 350 Ω ● When it is difficult to bond a gage to the surface of a bolt for
tightening stress measurement, etc., these KFG gages are embedded
into the hole bored from the top head of the bolt.
● Boring diameter: 2 mm
● Gage length: 1.5, 3 mm
● Applicable linear expansion coefficient: 11 x10–6/°C
● Operating temperature range: Room temp. to 50°C
High-Elongation Foil Strain Gages
● Enabling strain measurement in elastic to
plastic region.
● Enabling strain measurement for maximum
elongation of approximately 10 to 15% Coating Agents
● Suitable for tensile tests of materials
● Gage length: 2, 5 mm ● Coating agents are applied to strain gages and gage terminals to
● Gage pattern: Uniaxial, biaxial 0°/90°, triaxial prevent them from adsorbing moisture. These agents are available in a
0°/90°/45° variety of types including wax, rubber and putty.
● Resistance: 120 Ω
● Operating temperature range: –10 to 80°C Adhesives
● To ensure better measuring results, various kinds of adhesives are
available for selection based on measuring objects, gage base
materials and measuring conditions.

Gage Terminals
● To protect gage leads, gage terminals are applied to the connection
between strain gages and leadwires. They are available in various
materials and shapes.

3
Load Cells

Small-Sized Compression Load Cells General-Purpose Compression Load Cells


● Ultra-small, lightweight and low cost ● Rated capacity: 500 N to 200 kN
● Rated capacity: 5 N to 1 kN ● System accuracy: Within ±0.1% RO
● System accuracy: Within ±1% RO (within ±0.2% RO with 500N)
● Nonlinearity: Within ±1% RO LMA-A-5 to 50N ● Nonlinearity:Within ±0.1% RO
● Hysteresis: Within ±1% RO (within 0.2% RO with 500N)
● Rated output: 0.75 to 2 mV/V ● Hysteresis: Within ±0.1% RO
(0.6 to 2 mV/V with 500GA) (within ±0.2% RO with 500N)
● Safe overload rating: 150% LMA-A-100N to 1KN
● Rated output: 1.5 mV/V ±0.2%
● Dimensions & mass: 12 mmφ x 4 mm high, approx. 13 g; ● Safe overload rating: 200%
20 mmφ x 9.5 mm high, approx. 23 g ★ High and low-temperature models (LC-FH/FL) are also available.

Small-Sized Compression Load Cells


Compression Load Cells
● Small, lightweight and low cost
● Rated capacity: 2 to 20 kN ● Highly accurate and reliable
● Nonlinearity: Within ±1% RO ● Rated capacity: 500 N to 50 kN
(within ±2% RO with 20KNSA2) ● Nonlinearity: Within ±0.05% RO
● Hysteresis:Within ±1 %RO ● Hysteresis: Within ±0.05% RO
(within ±2% RO with 20KNSA2) ● Rated output: 2 mV/V ±0.1%
● Rated output: 1 mV/V or more ● Safe overload rating: 150%
● Safe overload rating: 120% ● Fatigue life: 1 million times or more
● Dimensions & mass: 21 mmφ x 10 mm high, approx. 25 g
Thin Compression Load Cells
Small-Sized Compression Load Cells
● Thickness: 25 mm (5 to 20KN)
● Stainless steel enclosure ● Rated capacity: 5 to 200 kN
● Small, lightweight and low cost ● Nonlinearity: Within ±0.2% RO
● Rated capacity: 500 N to 20 kN (within ±0.5% RO with 200KN)
● System accuracy: Within ±0.15% RO ● Hysteresis: Within ±0.2% RO
● Nonlinearity: Within ±0.15% RO (within ±0.5% RO with 200KN)
● Hysteresis: Within ±0.1% RO ● Rated output: 2 mV/V ±0.5%
● Rated output: 2 mV/V ±0.3% ● Safe overload rating: 150%
● Safe overload rating: 200%
● Dimensions & mass: 50 mmφ x 25 mm high, approx. 220 g
High-Accuracy Compression Load Cells
Small-Capacity Compression Load Cells
● Long-term accurate measurement possible under severe conditions
● Rated capacity: 100, 200 kN
● Small capacity
● Nonlinearity: Within ±0.02% RO
● Highly accurate
● Hysteresis: Within ±0.02% RO
● Rated capacity: 50 to 200 N
● Rated output: 2 mV/V ±0.1%
● Nonlinearity: Within ±0.3% RO
● Safe overload rating: 200%
● Hysteresis: Within ±0.2% RO
● 6-conductor cable (remote sensing)
● Rated output: 1.5 mV/V ±0.5%
is adopted.
● Safe overload rating: 120%
● Dimensions & mass: 90 mmφ x 58 mm high, approx. 1.6 kg
Tension Load Cells
Small-Sized Compression Load Cells
● Highly accurate and reliable
● Rated capacity: 500 N to 50 kN
● Compact and lightweight
● Nonlinearity: Within ±0.05% RO
● Rated capacity: 50 to 200 kN
● Hysteresis: Within ±0.05% RO
● System accuracy: Within ±0.05% RO
● Rated output: 2 mV/V ±0.1%
● Nonlinearity: Within ±0.05% RO
● Safe overload rating: 150%
● Hysteresis: Within ±0.05% RO
● Cycling life: 1 million times or more
● Rated output: 2.5 mV/V ±0.2%
● Safe overload rating: 150%
● Cycling life: 10 million times or more General-Purpose Tension Load Cells
Small-Sized Compression Load Cells
● Small-sized
● Rated capacity: 500 N to 200 kN
● Small, lightweight and large capacity ● Nonlinearity: Within ±0.1% RO
● Rated capacity: 500 kN, 1 MN (within ±0.5% RO with 500N)
● Nonlinearity: Within ±0.1% RO ● Hysteresis: Within ±0.1% RO
● Hysteresis: Within ±0.1% RO (within ±0.5% RO with 500N)
● Rated output: 2.5 mV/V ±0.2% ● Rated output: 1.5 mV/V ±0.2%
● Safe overload rating: 150% ● Safe overload rating: 200%
● Cycling life: 10 million times or more ● Critical overload: 500%
★ High and low-temperature models (LT-FH/LT-FL)
General-Purpose Compression Load Cells are also available.

Tension/Compression Load Cells


● Highly stable
● Hermetically sealed structure with inert gas filled in
● Rated capacity: ±500 N to 200 kN
● Rated capacity: 2, 5 MN
● Nonlinearity: Within ±0.2% RO
● Nonlinearity: Within ±0.5% RO
● Hysteresis: Within ±0.1% RO
● Hysteresis: Within ±0.2% RO
● Rated output: 2 mV/V ±0.2%
● Rated output: 2 mV/V ±1%
● Safe overload rating: 150%
● Safe overload rating: 150%

4
Load Cells

High-Accuracy Tension Load Cells Beam-Shape Load Cells

● Compact, lightweight, and easy to use and maintain ● Compact, lightweight and low cost
● Rated capacity: 500 N to 50 kN ● Metal bellows adopted
● System accuracy: Within ±0.03% RO ● Rated capacity: 50 N to 20 kN
(within ±0.05% RO with 500KA or larger) ● System accuracy: Within ±0.03% RO
● Nonlinearity: Within ±0.03% RO (within ±0.05% RO with 500KA or larger) (within ±0.05% RO with 100KB or larger)
● Hysteresis: Within ±0.03% RO (within ±0.05% RO with 500KA or larger) ● Nonlinearity: Within ±0.03%RO
● Rated output: 3 mV/V ±0.2% (within ±0.05% RO with 100KB or larger)
● Safe overload rating: 150% ● Hysteresis: Within ±0.03% RO (within ±0.05% RO with 100KB or larger)
● Rated output: 2 mV/V ±0.3%
● Safe overload rating: 150%

Load Cells for Minute Load Measurement


LTZ-50 to 200KA LTZ-500KA to 2TA
● Enable highly accurate measurement of minute load.
● 2 types are available: LVS senses load in vertical direction
to the
Small-Sized Tension/Compression Load Cells mounting surface and LTS senses load in horizontal direction to the
mounting suface.
● Rated capacity
LVS: 50 mN to 20 N
● Suitable for load measurement of small-sized pressing machines and LTS: 500 mN to 20 N
press-fitting devices ● Nonlinearity: Within ±0.5% RO
● Compact and lightweight design ensures easy
● Hysteresis: Within ±0.5% RO
incorporation into equipment ● Rated output: ±1.5 mV/V or more
● Rated capacity: ±500 N to 20 kN
● Safe overload rating: 120%
● Nonlinearity: Within ±0.1% RO
● Mass: Approx. 50 g
(within ±0.15% RO with 2KN or smaller) LVS-A
● Hysteresis: Within ±0.1% RO
(within ±0.15% RO with 2KN or smaller)
● Rated output: 1.3 mV/V or more 3-Component Force Transducer
(0.9 mV/V or more with 1KN or smaller)
● Safe overload rating: 150%
● Compact, lightweight, and easy to handle
● Rated capacity: 10 to 500 N with all force
Small-Capacity Tension/Compression Load Cells components Fx, Fy and Fz
● Nonlinearity: Within ±0.5% RO
● Hysteresis: Within ±0.5% RO
● Small capacity ● Rated output: Approx. 0.5 mV/V
● High accuracy ● Safe overload rating: 150%
● Rated capacity: ±50 to 200 N ● Interference: ±3% RO
● Nonlinearity: Within ±0.3% RO
● Hysteresis: Within ±0.2% RO
● Rated output: 1.5 mV/V ±0.5%
● Safe overload rating: 120% 6-Component Force Measuring System
Small-Sized Tension/Compression Load Cells ● Consists of 6-compornent force transducer LAT-A, signal processor
FDP-106A, communications program and PC
● Rated capacity: Fx, Fy = 100, 200, 300 N
● Compact, lightweight, 28 mm in diameter Fz = 200, 300 N
● Rated capacity: ±50 N to 2 kN Mx, My, Mz = 10, 20 N.m
● Nonlinearity: Within ±0.5% RO ● Number of channels: 6 (FDP-106A)
● Hysteresis: Within ±0.5% RO ● Analog output: ±5 V
● Rated output: 0.5 mV/V or more ● PC interface: RS-232C
(Approx. 0.4 mV/V with 50NSA1) ● With load point compensation and alarm output
● Safe overload rating:
150% ● Dimensions & mass (transducer): 70 mmφ x 44 mm high, approx. 250 g
● Mass: Approx. 80 g

High-Accuracy Tension/Compression Load Cells Washer-Type Load Cells

● Models of the same capacities are available with different diameters.


● Excellent zero-float characteristic (50 to 500KF) ● Thin design makes them suitable for
● Rated capacity: ±500 N to 200 kN
industrial applications.
● Nonlinearity: Within ±0.02% RO ● Rated capacity: 10 to 300 kN
● Hysteresis: Within ±0.02% RO ● Hysteresis: Within ±1% RO
● Rated output: 2 mV/V ±0.1% ● Rated output: Approx. 1 mV/V
● Safe overload rating: 150% ● Safe overload rating: 150%
● 6-conductor cable (remote
sensing) is adopted.

Stainless Steel Load Cells


Tension/Compression Load Cells
● For weighing of tanks and hoppers
● Thin design ● Thin, top and bottom plates integrated, and steady brace provided
● Rated capacity: ±5 kN to 2 MN ● Rated capacity: 4.903 to 98.07 kN (500 kgf to 10 tf)
● Nonlinearity: Within ±0.1% RO ● Nonlinearity: Within ±0.03% RO
(within ±0.2% RO with 500KNSA1 or larger) ● Hysteresis: Within ±0.03% RO
● Hysteresis: Within ±0.1% RO ● Rated output: 2 mV/V ±0.1%
(within ±0.2% RO with 500KNSA1 or ● Safe overload rating: 150%
larger)
● Rated output: 2 mV/V ±1 % (±10% with 5 to 20KNSA1)
● Safe overload rating: 150%

5
Load Cells Pressure Transducers

Thin Load Cells "Multiforce Sensor" Small-Sized Pressure Transducers


PGL-A
● Endure lateral load and highly accurate. ● Rated capacity: 1 to 50 MPa
● Rubber attachment enables use with the top and bottom fixed. ● Nonlinearity: Within ±0.3% RO (within ±0.5% RO with 2MPa or smaller)
● Rated capacity: 4.903 to 2942 N (50 to 300 kgf) ● Hysteresis: Within ±0.2% RO
● Nonlinearity: Within ±0.05% RO (within ±0.5% RO with 2MPa or smaller)
● Hysteresis: Within ±0.05% RO ● Rated output: 2 mV/V ±20% (within±25% with 2MPa or smaller)
● Rated output: 2 mV/V ±0.2% ● Safe overload rating: 150%
● Safe overload rating: 150% ● Material: Metal finish
● Mounting screw: G1/8, male
● Cable-integrated models are
available.

Small-Sized High/Low Temp. Pressure Transducers


Thin Load Cells "Multiforce Sensor"
M4AL2 ● Safe temperature range: –196 to 210°C
● Rated capacity: 4.903 to 49.03 kN (500 kgf to 5 tf) ● Rated capacity: 1 to 50 MPa
● Nonlinearity: Within ±0.03% RO ● Nonlinearity: Within ±0.3% RO
● Hysteresis: Within ±0.03% RO (within ±0.5% RO with 2MPa or smaller)
● Rated output: 1.5 mV/V ±0.2% ● Hysteresis: Within ±0.2% RO
● Safe overload rating: 150% (within ±0.5% RO with 2MPa or smaller)
● Rated output: 2 mV/V ±20%
(within ±25% with 2MPa or smaller)
● Safe overload rating: 150%
● Material: Metal finish
● Mounting screw: G1/8, male
Thin Load Cells "Multiforce Sensor"
Pressure Transducers
● Rated capacity: 9.807 to 98.07 kN (1 to 10 tf)
● Nonlinearity: Within ±0.03% RO ● Rated capacity: 200 kPa to 50 MPa
● Hysteresis: Within ±0.03% RO ● System accuracy: Within ±0.2% RO (within ±0.3% RO with 2 to 10KU)
● Rated output: 2 mV/V ±0.2% ● Nonlinearity: Within ±0.2% RO (within ±0.3% RO with 2 to 10KU)
● Safe overload rating: 150% ● Hysteresis: Within ±0.2% RO (within ±0.3% RO with 2 to 10KU)
● Rated output: 2 mV/V ±0.5% (±1% with 2 to 10KU)
● Safe overload rating: 150%
● Materials: Aluminum, alumite treated
(mainframe), ZDC, chrome-plated
(mainframe) with 10KU or larger,
SUS 630 (liquid-contacting part)
● Mounting screw: G1/8, male
Thin Load Cells "Multiforce Sensor"
Small-Sized Pressure Transducers
● Rated capacity: 98.07 to 294.2 kN (10 to 30 tf)
● Nonlinearity: Within ±0.03% RO
● Compact, lightweight, and highly durable; vibration acceleration 490.3
● Hysteresis: Within ±0.03% RO
m/s2, impact accleration 4903 m/s2
● Rated output: 2 mV/V ±0.2%
● Rated capacity: 1 to 50 MPa
● Safe overload rating: 150%
● Nonlinearity: Within ±0.2% RO (within ±0.3% RO with 20KA, within
±0.4% RO with 10KA)
● Hysteresis: Within ±0.2% RO
● Rated output: 2 mV/V ±0.5%
● Safe overload rating: 150%
● Materials: Aluminum, alumite treated
(mainframe), SUS 630 (liquid-
contacting part)
● Mounting screw: G3/8, male

High Pressure Transducers

●Rated capacity: 100, 200 MPa


●System accuracy: Within ±0.2% RO
●Nonlinearity: Within ±0.2% RO
●Hysteresis: Within ±0.2% RO
●Rated output: 1.5 mV/V ±0.5%
●Safe overload rating: 150%
●Materials: SUS metal finish (mainframe), SUS 630 (liquid-contacting part)
●Mounting screw: G1/2, male

Small-Sized Pressure Transducers

● Flush diaphragm type for measurement of highly viscous medium


● Rated capacity: 500 kPa to 50 MPa
● System accuracy: Within ±0.3% RO
(within ±1% RO with 5 to 20KH)
● Nonlinearity: Within ±0.3% RO
(within ±0.5% RO with 5 to 20KH)
● Hysteresis: Within ±0.2% RO
● Rated output: 2 mV/V or more (1.5 mV/V or more with 5KH)
● Safe overload rating: 150%
● Materials: SUS metal finish (mainframe), SUS 630 (liquid-contacting part)
● Mounting screw: G3/8, male

6
Pressure Transducers

Small-Sized Pressure Transducers High/Low-Temperature Pressure Transducers

● Flush diaphragm type ● Safe temperature range: –196 to 210 °C


● Rated capacity: 1 to 50 MPa ● Rated capacity: 1 to 50 MPa
● System accuracy: Within ±1% RO ● System accuracy: Within ±0.5% RO
● Nonlinearity: Within ±1% RO ● Nonlinearity: Within ±0.4% RO
● Hysteresis: Within ±1% RO ● Hysteresis: Within ±0.4% RO
● Rated output: 1 mV/V or more (1.4 mV/V or more with 500KE) ● Rated output: 2.2 mV/V ±15%
● Safe overload rating: 150% ● Safe overload rating: 120%
● Materials: SUS metal finish (mainframe), ● Materials: SUS metal finish (mainframe),
SUS 630 (liquid-contacting part) (SUS 630 and SUS 304 with 10 and 20KE) SUS 630 (liquid-contacting part)
● Mounting screw: G3/8, male ● Mounting screw: G3/8, male

Small-Capacity Pressure Transducers Small-Sized High-Temp. Pressure Transducers


PHF-S-SA2
● Communicating tube incorporated in the cable for back pressure compensation
● Safe temperature range: –40 to 170 °C
● Rated capacity: 20 to 100 kPa
● Compact and lightweight
● System accuracy: Within ±0.5% RO
● Rated capacity: 2 to 20 MPa
● Nonlinearity: Within ±0.5% RO
● Nonlinearity: Within ±0.3% RO
● Hysteresis: Within ±0.3% RO
(within ±0.4% RO with 2MPSA2)
● Rated output
● Hysteresis: Within ±0.2% RO
PGM-02KG: 0.75 mV/V or more ● Rated output: 2 mV/V
PGM-05KG: 1.25 mV/V or more ● Safe overload rating: 150%
PGM-1KG: 1.4 mV/V or more ● Mounting screw: G1/8, male
● Safe overload rating: 150%
● Materials: SUS metal finish (mainframe), SUS 304 (liquid-contacting part)
● Mounting screw: M14 P = 1, male
Miniature Pressure Transducers
Small-Sized Pressure Transducers
● Thin, small in diameter, lightweight, intended for distributed pressure
● Pressure sensing part diameter as small as 5.5 mm measurement
● Flush diaphragm type ● Bondable with adhesive
● Rated capacity: 200 kPa to 1 MPa ● Rated capacity: 50 kPa to 7 MPa
● System accuracy: Within ±1.5% RO ● Nonlinearity: Within ±1% RO
● Nonlinearity: Within ±1.5% RO ● Hysteresis: Within ±1% RO
● Hysteresis: Within ±1.5% RO ● Rated output: 0.275 to 1 mV/V
● Rated output ● Safe overload rating: 150%
PGM-2KC: 0.6 mV/V or more ● Mass: Approx. 0.15 to 0.5 g
PGM-5KC, 10KC: 1 mV/V or more ±20% ● Type A: Flat, type B: Conical;
● Safe overload rating: 150% Type A is available only
● Materials: C1720 (liquid-contacting part), SUS 303 (screw) for PSM series.
● Mounting screw: G1/8, male

Small-Sized Stainless Steel Pressure Transducers Differential Pressure Transducers

● High line pressure margin


● Small pressure sensing surface, flush diaphragm type
● Rated capacity: 10 to 200 kPa
● Rated capacity: 5 to 50 MPa
● Nonlinearity: Within ±0.3% RO
● System accuracy: Within ±0.5% RO
● Hysteresis: Within ±0.2% RO
● Nonlinearity: Within ±0.5% RO
● Rated output: 1.5 mV/V ±1%
● Hysteresis: Within ±0.5% RO
● Safe overload rating (differential
pressure)
● Rated output: 1.5 mV/V ±20%
● Safe overload rating: 150% 100, 200GA: 200%
● Materials: SUS metal finish (mainframe), SUS 630 (liquid-contacting part) 500GA, 1KA: 150%
● Mounting screw: G1/8, male 2KA: 125%
● Maximum line pressure: 2.94 MPa

Absolute Pressure Transducers


PAB-A
● Measurement from absolute pressure zero (vacuum) possible
● Rated capacity: 200 kPaabs to 2 MPaabs Micro Differential Pressure Transducers
● Nonlinearity: Within ±0.1% RO
● Hysteresis: Within ±0.1% RO
● Rated output: 2 mV/V or more ● Compact, lightweight, quick response,
● Safe overload rating: 150% high accuracy and high sensitivity
● Material: SUS 630 ● Rated capacity: 1 to 7 kPa
(liquid-contacting part) ● Nonlinearity: Within ±0.5% RO
● Mounting screw: 7/16-20UNF (within 0.7% RO with 25GA)
● Hysteresis: Within ±0.3% RO
PDS-A
● Rated output
Highly Reliable Sputter Gage Pressure Transducers PDS-10GA: ±7 to 23 mV
PDS-25 to 70GA: ±13 to 23 mV
PDV-A: ±5 V
● Safe temperature range: -196 to 230 °C ● Safe overload rating
● Long-term stable measurement at 200 °C PDS/PDV-10GA: 600%
● Absolute pressure measurement possible PDS/PDV-25 to 70GA: 300% PDV-A
● Excellent high-temperature characteristics
● Rated capacity: 200 kPaabs to 20 MPaabs
● Nonlinearity: Within ±0.2% RO
● Hysteresis: Within ±0.2% RO
● Rated output: 1.5 mV/V or more
● Safe overload rating: 150%
● Materials: SUS metal finish (mainframe), SUS 630 (liquid-contacting part)
● Mounting screw: G3/8, male

7
Acceleration Transducers

Small-Capacity Acceleration Transducers Waterproof Acceleration Transducers


AS-GA, GB
● Compact and lightweight design gives ● Usable under water and soil
minimal effect to vibration mode. ● Rated capacity: ±9.807 to 196.1 m/s2
● Rated capacity: ±9.807 to 196.1 m/s
2 ● Nonlinearity: Within ±1% RO
● Nonlinearity: Within ±1% RO ● Hysteresis: Within ±1% RO
● Hysteresis: Within ±1% RO AS-GA ● Rated output: 0.5 mV/V or more
● Rated output: 0.5 mV/V or more ● Safe overload rating: 300%
● Safe overload rating: 300% ● Hydraulic resistance: 490.3 kPa
● Frequency response range: DC to (40 to 250) Hz ● Frequency response range: DC to (40 to 250) Hz
● Mass: Approx. 15 g (GA), 25 g (GB) ● Mass: Approx. 40 g

Small-Sized Acceleration Transducers Semiconductor Acceleration Transducers


AS-A, B with Built-in Amplifier
● Rated capacity: ±19.61 to 980.7 m/s 2
● Compact and lightweight
● Nonlinearity: Within ±2% RO
● Cycling life: 10 million times
● Hysteresis: Within ±1% RO
● Rated capacity: ±980.7 to 9807 m/s2 (A), ±98.07 to 490.3 m/s (B)
2
● Rated output: ±2 V ±0.1 V
● Nonlinearity: Within ±1% RO
● Hysteresis: Within ±1% RO (minus rated capacity 0.5 V to zero,
● Rated output: 0.5 mV/V or more (A), 2.5 V to plus rated capacity 4.5 V)
● Safe overload rating: 1000%
0.5 mV/V ±20 % (±25% with 10B) (B)
● Power supply: 12 VDC (8.0 to 30.0 V),
● Safe overload rating: 300%
● Frequency response range: approx. 6.5 mA
● Mass: Approx. 13 g
DC to (1.2 to 5) kHz (A)
DC to (300 Hz to 1 kHz) (B)
● Mass: Approx. 6.5 g (A), 13 g (B)
★ Model 200A or larger falls under export regulations. Semiconductor Acceleration Transducers

● Compact and lightweight design gives minimal effect to vibration mode.


● Rated capacity: ±490.3 to 4903 m/s2
Quick Response Acceleration Transducers ● Nonlinearity: Within ±2% RO
● Hysteresis: Within ±1% RO
AS-HA, HB ● Rated output: 6 mV/V or more
● Rated capacity: ±980.7 to 9807 m/s2 (HA), ±98.07 to 490.3 m/s2 (HB) ● Frequency response range:
● Nonlinearity: Within ±1% RO DC to (600 Hz to 1.5 kHz)
● Hysteresis: Within ±1% RO ● Mass: Approx. 3.5 g
● Rated output: 0.5 mV/V ±20% ● Model 200GA or larger falls under export regulations.
(±25% with 10HB)
● Safe overload rating: 300%
● Frequency response range:
DC to (2 to 7) kHz (HA) Servo Acceleration Transducers/Dedicated Conditioner
DC to (500 Hz to 1.5 kHz) (HB)
● Mass: Approx. 6.5 g (HA), 13 g (HB)
★ Model 200HA or larger falls under export regulations. Acceleration Transducers
● For minute vibration measurement
● Connector type (ASQ-CA) and cable-integrated type
(ASQ-CB) are available.
● Rated capacity: ±9.807, ±19.61, ±49.03 m/s
2

Small-Sized Triaxial Acceleration Transducers ● Nonlinearity: Within ±0.03% RO


● Hysteresis: Within ±0.05% RO
● Rated output: ±5 V (10 V) ±5%
● Simultaneous measurement of acceleration in X, Y and Z directions. Dedicated Conditioner VAQ-700A
● Rated capacity: ±9.807 to 196.1 m/s2 ● Number of measuring channels: 1 (multi-channel
● Nonlinearity: Within ±1% RO configuration available)
● Hysteresis: Within ±1% RO ● Enables simultaneous measurement of acceleration,
● Rated output: 0.5 mV/V or more velocity and displacement.
● Safe overload rating: 1000% (with stopper) ● Measuring range
● Frequency response range: Acceleration: ±9.807 m/s2 (±1 G), ±19.61 m/s2 (±2 G),
DC to (40 to 250) Hz ±49.03 m/s2 (±5 G)
● Mass: Approx. 110 g Velocity: ±100, ±200, ±500 cm/s
Displacement: ±100, ±200, ±500 mm
● Output: ±10 V
● Dimensions & mass:
ASQ-CA
49 x 128.5 x 262.5 mm,
approx. 1.4 kg
Triaxial Acceleration Transducers
AS-TA, TB
● Rated capacity: ±98.07 to 9807 m/s2
● Nonlinearity: Within ±1% RO
● Hysteresis: Within ±1% RO
● Rated output: 0.5 mV/V or more (TA),
0.5 mV/V ±20% (TB) (±25% with 10TB)
● Safe overload rating: 300% (each axis)
● Frequency response range:
DC to (1.2 to 5) kHz (TA)
DC to (350 Hz to 1 kHz) (TB)
● Mass: Approx. 45 g (TA), 95 g (TB)
★ Model 200TA or larger falls under export regulations.
VAQ-700A

8
Torque Transducers

Highly Rigid Torque Transducers High-Speed Torque Transducers

● No contact part such as slip ring or bearing ● For small torque measurement
● Suitable for use at high-speed revolutions ● Equipped with overload prevention stopper
● Rated capacity: ±500 N.m to 50 kN.m ● Rated capacity: 0.2 to 5 N.m
● Nonlinearity: Within ±0.2% RO ● Nonlinearity: Within ±0.2% RO
(within ±0.5% RO with 1TMA or larger) ● Hysteresis: Within ±0.2% RO
● Hysteresis: Within ±0.2% RO ● Rated output: 0.75 to 1.5 mV
(within ±0.5% RO with 1TMA or larger) ● Safe overload rating: 150% (stopper
● Rated output: ±10 V, 4 to 20 mA operates at 150%.)
● Safe overload rating: 150% ● Maximum speed: 3000 to 15000 rpm
(120% with 1TMA or larger)
(Output is saturated at 110%.)
● Maximum speed: 3000 to 10000 rpm

Torque Transducers Rotary Transformer Torque Transducers


TP-AB, CB TPN-AB, CB
● Bending or thrust of the shaft causes minimal adverse effect, thereby ● Non-contact design facilitates maintenance.
enabling highly accurate measurement. ● TPN-AB with no installation feet and TPN-CB with installation feet
● TP-AB with no installation feet and TP-CB with installation feet ● Rated capacity: 10 to 500 N.m
● Rated capacity: 5 N.m to 5 kN.m ● Nonlinearity: Within ±0.2% RO
● Nonlinearity: Within ±0.2% RO ● Hysteresis: Within ±0.2% RO
● Hysteresis: Within ±0.2% RO ● Rated output: 1.2 mV or more
● Rated output: 1.5 mV/V ±0.2% (±0.5% with 500KM) ● Safe overload rating: 150%
● Safe overload rating: 120% ● Maximum speed: 5000 to 12000 rpm
● Maximum speed: 2500 to 9000 rpm ● Mating amplifier: DPM dynamic strain amplifier (carrier: 5 kHz)

TP-CB
TPN-CB

Small-Sized Torque Transducers Slip Rings


TP-D, E RBE-A, E
● For small torque measurement ● Highly resistant against eccentricity, shock and vibration
● TP-D with no installation feet and TP-E with installation feet ● Small contact resistance ensures highly stable measurement.
● Rated capacity: 0.2 to 2 N.m ● Number of rings: 4 to 12
● Nonlinearity: Within ±1% RO ● Operating speed
● Hysteresis: Within ±1% RO RBE-A: 0 to 6000 rpm
● Rated output: 0.75 to 1.5 mV/V RBE-4E: 3000 to 25000 rpm
● Safe overload rating: 120% RBE-8E, 12E: 3000 to 15000 rpm
● Maximum speed: 4000 rpm ● Service life of brush (when operated at the maximum speed)
RBE-A: Approx. 110 hours
RBE-E: Approx. 50 hours

TP-E
RBE-E

9
Displacement Transducers

Displacement Transducers Potentiometer Displacement Transducers

● Compact, lightweight, highly accurate and high output level ● For large displacement measurement
● Rated capacity: 5 to 100 mm ● Compact, lightweight and high output level
● Nonlinearity: Within ±0.1% RO ● Rated capacity: 500 to 5000 mm
● Hysteresis: Within ±0.1% RO ● Nonlinearity: Within ±0.3% RO
● Rated output: 5 mV/V ±0.1% ● Hysteresis: Within ±0.3% RO
● Measuring force: Approx. 1.5 to 4 N ● Rated output: 5 mV/V ±0.3%
● Measuring force: Approx. 0.98 to 1.67 N
● Safe overload rating: 120%
● Flexible steady point type is available.

DTP-D-5KS
DTP-D-500S
DTP-D-2KS
Displacement Transducer

● Direct-reading scale provided Inductance Displacement Transducers


● Rated capacity: 200 mm DLT-AS, BS
● Nonlinearity: Within ±0.3% RO
● Hysteresis: Within ±0.3% RO ● Less abrasion and small measuring force
● Rated output: 5 mV/V ±0.3% ● Mating amplifier: DPM dynamic strain amplifier (carrier: 5 kHz)
● Measuring force: Approx. 5.9 N ● Rated capacity: ±5 to 500 mm
● Nonlinearity: Within ±0.5% RO
● Hysteresis: Within ±0.5% RO
● Rated output: Approx. ±2 mV/V

Displacement Transducers
Clip Type Displacement Transducers
● Direct-reading scale provided
● Rated capacity: 50, 100 mm
● Nonlinearity: Within ±0.5% RO ● For materials tests, with overload prevention stopper
● Hysteresis: Within ±0.5% RO ● Mounting chip is optionally available.
● Rated output: 1.5 mV/V ±20% ● Rated capacity: 2, 5 mm
● Measuring force: Approx. 4.4 N ● Nonlinearity: Within ±1% RO
● Hysteresis: Within ±1% RO
● Rated output: 2.5 mV/V +20%/–10%
● Safe overload rating: 130%

DTC-A-5

DTC-A-2
Dial Gage Displacement Transducers

● Direct-reading dial gage provided


● Easy installation and maintenance
● Rated capacity: 10 to 50 mm
● Nonlinearity: Within ±0.5% RO
● Hysteresis: Within ±0.5% RO
● Rated output: 1.5 mV/V or more
● Measuring force: Approx. 1.47 to 1.77 N
● Safe overload rating: 100%

10
Dynamic Strain Amplifiers

Multi Conditioners

MCD-8A unit base


(with monitor and DPM-71A cards mounted)

● For optimum system configuration, various cards are available Monitor Card DPE-71A
including dynamic strain, signal conditioner, F-V converter, charge Speifications Common to All Conditioner Cards
amplifier and thermocouple. ● Number of measuring channels: 1
● All conditioner cards have the input and output isolated.
● Output: 2-way output (the same voltage is output to the BNC
● Excellent vibration resistance enables onboard application.
connector and centralized connector.)
● 8 and 16-channel unit bases are available for configuration of desire
Output voltage: ±5 V (5 kΩ load or more)
multichannel configuration.
● Dynamic strain amplifier card is provided with true electron type auto- ● Dynamic Strain Amplifier Cards DPM-71A/72A
balance system and with the CST system which cancels capacitive Model Frequency response range Carrier
unbalance by constantly tracking capacitive component.
● Input/output isolation system ensures high noise resistance and safety. DPM-71A DC to 2.5 kHz (deviation ±10%) 5 kHz
● Conforming to CE marking DPM-72A DC to 5 kHz (deviation ±10%) 12 kHz
Unit Bases MCD-8A/16A
● Models ● SignalConditioner Card CDV-71A
MCD-8A: To accommodate 8 conditioner cards
MCD-16A: To accommodate 16 conditioner cards ● Thermocouple Card CTA-71A
● Vibration resistance: 49.03 m/s2 (5 G) (5 to 55 Hz) ● F-V Converter Card CFV-71A
● Power source: 100 to 240 VAC, 9 to 18 VDC
● Charge Amplifier Card CCA-71A
● Dimensions & mass
MCD-8A: 264 x 132.5 x 300 mm (excluding protrusions),approx. 7 kg
MCD-16A: 426 x 132.5 x 300 mm (excluding protrusions), approx. 10 kg
● EMC standard: EN 61326-1 (common to all cards)
● Safety standard: EN 61010-1 (Installation category II, Pollution level 2)

11
Data Loggers

Data Loggers
UCAM-60A, 65A
Data Loggers UCAM-60A/65A
●Sensors and connectable scanners
External scanner

scanner
Internal
General purpose Civil engineering
Scanner
USB- USB- USB- USB- USB- USB-
Sensor 70A/B- 51A 51AT 20A/ 70A/B- 50D
10/20 50A 30
Strain gages & strain gage transducers
1-gage system
120 Ω
240 Ω
350 Ω
1-gage true dummy system
120 Ω
350 Ω
PC is not included.
2-gage system, 60 to 1000 Ω
Active-dummy method
The UCAM-60A data logger is an all-in-one instrument developed in full Active-active method
pursuit of easy handling in the field. The instrument is provided with all Common dummy method
functions required for measurement in the field, including easy-to-use 4-gage system, 60 to 1000 Ω*3
keys, bright readable display and printer for immediately confirming Opposite side active method
measured results. The UCAM-65A is an online version wholly controlled Full-bridge method
by the PC. Civil engineering transducers
Both models can measure up to 30 channels of data with the mainframe 4-gage system, 120 Ω
only, while external scanners enable measurement in up to 1000 Constant-current excitation
channels. Measured results are stored in internal memory and are saved 4-gage system, 350 Ω
in a flash ATA card if inserted in the PC card slot for offline data transfer Constant-current excitation
to the PC. In addition, the UCAM-60A and UCAM-65A are provided with With temp. measuring function
Ethernet and RS-232C ports which enable the PC to not only control Voltage output sensors (DC) *4
these data loggers through the control software UCS-60A but also Temperature
process data for rosette analysis, etc. in the field by directly receiving Thermocouple K (CA) *4
data. T (CC) *4
E (CRC) *4
J (IC) *4
UCAM-60A R
● Fluorescent display tube ensures easy observation in the field. *4
Platinum resistance thermometer sensor
● Built-in thermal printer enables immediate confirmation of measured
Pt100 (new JIS)
results. JPt100 (old JIS)
● Control
software UCS-60A (optional for UCAM-60A) can place the Potentiometer sensors
UCAM-60A under the control of the PC connected through Ethernet or Built-in lightning arrester
RS-232C port. *1
Scanner interface (USI-)*2 Not
required -67A -65A -67A -65A
UCAM-65A Notes: 1. With USS-63A mounted
● Withthe UCAM-65A, measuring conditions, etc. are set from the PC 2. Use either of the scanner interfaces for connection to external scanners.
and measured results are transferred to the PC. 3. 120 to 1000 Ω with high-resolution mode
● Can be used for interval measurement as a stand-alone unit with no 4. With the UST-10 temperature measuring unit mounted
PC connected. ● Number of measuring channels:
Max. 30 with dedicated scanners
Common to UCAM-60A and UCAM-65A Max. 1000 with external scanners
● Can measure up to 20000 µm/m with a resolution of 0.1µm/m. Max. 1000 with internal scanners plus external scanners
● Scanning speed:
● Scanning at 50 ms/channel
● High-speed scanning at 20 ms/channel is possible.
50 ms/channel (standard mode)
280 ms/channel (high-resolution mode)
● DC-operated version is available for operation where no AC outlet
is (Can be set for every channel.)
available. 20 ms/channel (high-speed mode)
● Configuration (Can be set for every channel.)
Mainframe: UCAM-60A ● PC card slot: Conforms to PCMCIA Ver. 4.2.
UCAM-65A Accepts commercially available flash ATA card.
Dedicated scanners mounted to mainframe: ● Interface: RS-232C, Ethernet (10BASE-T/100BASE-TX)
USS-61A ● Operating temperature & humidity range: 0 to 50 °C, 20 to 85%RH
USS-62A (with NDIS connectors) (noncondensing)
USS-62A M6 (with clamp-style terminal board and NDIS connectors) ● Power source: 85 to 264 VAC, 50/60 Hz (AC version)
USS-63A (with lightning arrester) 10 to 16 VDC (DC version)
Note: A dedicated scanner is provided with 10 channels and up to ● Dimensions
3 units can be mounted to the mainframe. UCAM-60A: 360 x 88 x 400 mm (excluding protrusions)
External scanners UCAM-65A: 327 x 88 x 365 mm (excluding protrusions)
● Mass: Approx. 8 kg (60A), 4.6 kg (65A)
USB-70 series (USI-67A scanner interface required)
USB-51A/51AT (USI-65A scanner interface required)
USB-20A/50A (USI-65A scanner interface required)
USB-50D (USI-65A scanner interface required) Control Software
Scanner interfaces
USI-67A for USB-70 series
USI-65A for USB-20/50/51 series The software enhances the performance of the data logger by letting the
External input/output unit UIO-60A PC present measured results in graphic and numeric formats as well as
Control software UCS-60A perform data analysis.
● Controls UCAM-60A, 65A, 20PC and 500A.
● Enables presentation of numeric list on the PC.
● Enables presentation of maximum 4 graphs at a time on the PC.
● Arithmetic operations, statistic operation and rosette analysis
● Reading and storage of measuring and calculating condition files
● PC
CPU: Pentium III 450 MHz or higher or the equivalent
OS: MS-Windows 98/98SE/Me/2000/XP
Memory: 256 MB or more
Hard disk: 10 MB or more (excluding data)

12
Data Loggers

High-Speed Data Logger

● Number of measuring channels: 50/scanner (which can accommodate


up to 5 different types of measuring units. (Each measuring unit
provides 10 channels.)
● Data update rate
Data update rate Number of meas. channels Number of scanners
1 time/sec 1 to 1000 1 to 20
2 times/sec 1 to 500 1 to 10
10 times/sec 1 to 200 1 to 4*
50 times/sec 1 to 100 1 to 2*
PC is not included. *Scanners are connected with each other using the US-50A synchronous cable.

This system consists of USB-500A scanner, UCAM-500A controller and ● Frequency response range: DC to 7.8 Hz (deviation: 0.5 to –3.5 dB)
the PC in which the UCS-500A control software is installed. The USB-500A ● Interface
performs multichannel measurement at high speed. The UCAM-500A Dedicated interface between controller and scanner and between
quickly records the measured data. The UCS-500A-installed PC sets, scanner and scanner
controls and operates the system for measurement and data acquisition. Dedicated interface cable: 2 m long (Each scanner is provided with
The scanner and controller are black box type with no operating part. one interface cable.) Total extensible length: Up to 185 m
The measuring speed ranges from 1000 channels/(1 time/sec) to 100 ● Operating temperature/humidity range: 0 to 40 °C, 20 to 85%RH
channels/(50 times/sec) and such high-speed measurement enables the (noncondensing)
system to cope with a wide range of phenomena from static to quasi- ● Power source: 85 to 264 VAC (no switchover required), 50/60 Hz;
dynamic. approx. 50 VA
Since the input accepts strain, voltage and temperature, the system can ● Dimensions: 426 x 133 x 300 mm (exluding protrusions)
measure signals from strain gages, strain gage transducers, potentiometer ● Mass: Approx. 6.5 kg (with five USS-51A strain units mounted)
sensors, voltage output sensors and thermocouples.
● Number of measuring channels: Max. 1000. Flexibly coping with Strain Unit USS-51A
measurement in small to large scale. ● Number of measuring channels: 10/unit
● Simultaneous sampling of all channels, ensuring simultaneity of data. ● Applicable sensors: Strain gages, strain gage transducers,
● Can measure static to quasi-dynamic phenomena (DC to several Hz). potentiometer sensors
● High-speed, large-capacity semiconductor memory enables long-term ● Bridge excitation: Constant voltage of 2 VDC (constantly applied)
data acquisition. ● Potentiometer excitation: Constant voltage of 2 VDC (constantly
● Control software operates on Windows 95/98/98SE/Me. applied)
● Arithmetic operations and data processing with built-in functions for ● Gage factor: 2.00 fixed (correctable with 2.00/Ks through the use of the
rosette analysis, etc. engineering unit conversion function)
● Wholly operated through the PC. ● Measuring range, resolution and accuracy (with static DC input)

Controller UCAM-500A (Mainframe) Type Range Measuring range Resolution Accuracy


● Number of connectable scanners: 1 to 20 units of USB-500A (max. L 0 to ±19000 µm/m 1 µm/m ±0.05%FS
Strain
1000 channels) H 0 to ±200000 µm/m 10 µm/m
● Functions: Controls scanners ±0.1%FS
Potentiometer sensors 0 to ±50% 0.01%
Acquires and saves data from scanners
Transfers data to the PC
● Memory: 64 MB
Measured data can be stored in high-speed, large-capacity Voltage Unit USV-51A
semiconductor memory during measurement in progress. ● Number of measuring channels: 10/unit
● Interface: ● Applicable sensors: Voltage output sensors (DC voltage)
Dedicated interface between controller and scanner Measuring range, resolution and accuracy (with static DC input)
GPIB between controller and the PC
● Operating temperature/humidity range: 0 to 40 °C, 20 to 85%RH Measuring range Resolution Accuracy Signal source resistance
(noncondensing) 0 to ±20.000 V 1 mV ±0.05%FS 50 Ω or less
● Power source: 85 to 264 VAC (no switchover required), 50/60 Hz;
approx. 50 VA
● Dimensions & mass: 426 x 88 x 300 mm (excluding protrusions),
approx. 6 kg Thermocouple Unit UST-51A
● Number of measuring channels: 10/unit
Scanner USB-500A ● Applicable sensors: Thermocouple
● Sensors and measuring units
Type Range Measuring range Resolution Accuracy
Thermo-
Measuring unit Strain Voltage
couple L –200.0 to 437.0 °C 0.1 °C ±0.8 °C
unit unit K
Sensor USS-51A USV-51A unit H –200.0 to 1200.0 °C 0.1 °C ±2.8 °C
UST-51A T –200.0 to 350.0 °C 0.1 °C ±0.7 °C

Strain gages & strain gage transducers
L –200.0 to 260.0 °C 0.1 °C ±0.5 °C
1-gage system E
120 Ω H –200.0 to 800.0 °C 0.1 °C ±1.7 °C
350 Ω L 0 to 330.0 °C 0.1 °C ±0.3 °C
J
1-gage true dummy system H 0 to 750.0 °C 0.1 °C ±1.9 °C
120 Ω
R — 0 to 1600.0 °C 0.2 °C ±2.2 °C
350 Ω
2-gage system, 120 to 1000 Ω
Active-dummy method
Active-active method Control Software UCS-500A (provided standard for UCAM-500A)
4-gage system, 120 to 1000 Ω ● Installed in the PC for setting, controlling and data acquisition
Opposite side active method ● PC
Full-bridge method CPU: Pentium 133 MHz or more (Pentium II 300 MHz or more
Potentiometer sensors recommended)
1 to 10 kΩ OS: MS-Windows 95/98/98SE/Me with Internet Explorer Ver. 3 or
Voltage ±20.0 V higher installed
Temperature Memory: 64 MB or more (128 MB or more recommended)
Thermocouple K (CA) Hard disk: 10 MB or more (except for data)
T (CC) Display: Resolution 800 x 600 dots or more and 256 colors or more
E (CRC)
J (IC)
R

13
Data Analyzers

Sensor Interfaces
Series

PC is not provided.

The PCD-300 series sensor interfaces make the existing PC a versatile PCD-300A
measuring instrument. The PCD-300A enables the PC to perform stress ● Applicable sensors: Strain gages, strain gage transducers
measurement through the use of strain gages and force, pressure, accel- ● Applicable gage resistance
eration and displacement measurement through the use of strain gage 1 or 2-gage system: 120Ω
transducers. The PCD-320A enables the PC to measure voltage signals. 4-gage system: 120 Ω to 1 kΩ
The sensor interfaces are connected to the PC via USB interface. ● Bridge excitation: 2 VAC rms, carrier: 1 kHz sine wave
Connect strain gages and voltage output sensors directly to the rear ● Balance adjustment range
input terminals of sensor interfaces and start the accessory control Resistance: ±2% (±10000 µm/m) or more
software PCD-30A. Then, the PC operates as a measuring instrument. Capacitance: 5000 pF or more
Once sensors are connected, interactive operation on the PC enables ● Balance adjustment method
the operator to obtain measured data in proper engineering units. One Resistance: True electron auto-balance system
sensor interface provides 4 channels and up to 4 units can be connected Capacitance: CST system (automatic tracking)
via USB hub to extend to a 16-channel system suitable for small-scale ● Nonlinearity: Within ±(0.1%FS + 1 digit)
measurement. Needless to say, the PCD-300A can freely be combined ● Gage factor: 2.00 fixed
with the PCD-320A for simultaneous measurement of strain and voltage ● Range: 7 steps of 200, 500, 1000, 2000, 5000, 10000 µm/m and OFF
signals. Thus, the PCD-300 series can effectively be utilized as measur- Accuracy: Within ±(0.5% of range) µm/m
ing tools in every scene including simple experiments and sophisticated ● Frequency band: DC to 200 Hz, deviation ±10%
measurement. ● Mass: Approx. 930 g (excluding accessory AC adapter)
● Model with NDIS connector (PCD-300A M18) and model with
●2 models are available: PCD-300A for strain measurement and PCD- frequency band of DC to 1 kHz (PCD-300A M19) are available.
320A for voltage measurement.
● Connected to the PC via USB interface
● One unit provides 4 channels and 4 units enable 16-channel PCD-320A
● Applicable sensors: Voltage output sensors
measurement.
● Input mode: Unbalanced
● Optional synchronous cable enables simultaneous sampling with 4
● Input resistance: 1 MΩ or more
units.
● Coupling: DC/AC switchable
● Synchronous connection enables simultaneous measurement of strain
● Range: 7 steps of 1, 2, 5, 10, 20, 50 V and OFF
and voltage.
● Frequency response range
● The control software PCD-30A, a standard provision, operates on
Windows 98/98SE/Me/2000/XP. DC coupling: DC to 1 kHz
● The PCD-30A supports both PCD-300A and PCD-320A. AC coupling: 0.2 Hz to 1 kHz
● Low cost Deviation: within +1/–3 dB
● Lowpass filter
● Compact and lightweight
● Optional analysis software DAS-100A enables data analysis on the PC. Transmission characteristics: 2nd order Butterworth
Cutoff frequency: 5 steps of 10, 30, 100, 300 Hz and FLAT
Specifications common to PCD-300A and PCD-320A Amplitude ratio at cutoff point: –(3 ± 1) dB/oct.
● Number of measuring channels: 4 (up to 4 units can be connected Attenuation: –(12 ± 1) dB/oct.
● Measuring input terminals: BNC connectors
together for 16-channel measurement.)
● A-D converter: Resolution12-bit, successive approximation, Input/output not isolated
simultaneous sampling Max. allowable input voltage: 30 VAC or 60 VDC
● Sampling frequency: 1 Hz to 5 kHz Max. rated grounding voltage: 30 VAC or 60 VDC
● Mass: Approx. 750 g (excluding accessory AC adapter)
● External trigger signal: No-voltage conact, open collector, 5 V CMOS
level, number of points: 1
● Interface: USB Software PCD-30A
● Operating temperature/humidity range: 0 to 40 °C, 20 to 85%RH The control software PCD-30A enables the PC to control the sensor
(noncondensing) interfaces PCD-300A/PCD-320A. Using the software, the PC sets
● Power source: 100 to 240 VAC (AC adapter provided standard) measuring conditions and performs data acquisition, graph display and
● Dimensions: 265.2 x 24.7 x 215 mm (excluding protrusions) file conversion to CSV format on MS-Windows 98/98SE/Me/2000/XP.
● Safety standard: EN61010-1, installation category II, pollution degree 2 The software is supplied in CD-R and for use, it is installed in the hard
● EMC standard: EN61326-1, class A instrument disk of the PC.

14
Data Analyzers

Compact Recorder

The EDS-400A is a compact 4-channel recorder equipped with signal ● Typical recording time with 128-MB CF card (standard accessory)
conditioners and high-speed 16-bit resolution A-D converters, enabling
high-speed digital recording of dynamic strain and voltage phenomena. Sampling Number of measuring channels
Desired measuring and recording conditions are set to the recorder by frequency 1 2 3 4
communicating with the PC through LAN or by inserting a compact flash 100 kHz 8.0 minutes
memory card in which the conditions are written beforehand.
Measured data is directly written in the compact flash memory card, 50 kHz 16 minutes 8.0 minutes
while it is possible to monitor the waveform on the PC during data 20 kHz 40 minutes 20 minutes 13 minutes 10 minutes
acquisition in progress. 10 kHz 80 minutes 40 minutes 26 minutes 20 minutes
Acquired data is transferred to the PC either on line via LAN or off line via 5 kHz 160 minutes 80 minutes 53 minutes 40 minutes
the compact flash memory card.
The accessory software enables the PC to display the waveform of the 2 kHz 6.6 hours 3.3 hours 133 minutes 100 minutes
collected data, while the optional DAS-100A data analysis software 1 kHz 13 hours 6.6 hours 4.4 hours 3.3 hours
enables data analysis in various modes. 500 Hz 26 hours 13 hours 8.8 hours 6.6 hours
200 Hz 2.7 days 33 hours 22 hours 16 hours
● Compact and lightweight design requires less space. 100 Hz 5.5 days 2.7 days 44 hours 33 hours
● 4-channel measurement possible with a single unit 50 Hz 11 days 5.5 days 3.7 days 2.7 days
● Up to 8 units can be connected for 32-channel measurement.
● Maximum sampling frequency of 100 kHz (1-channel measurement)
20 Hz 27 days 13 days 9.2 days 6.9 days
ensures high-speed recording. 10 Hz 55 days 27 days 18 days 13 days
● Simultaneous sampling of 4 channels is possible at 20 kHz. 5 Hz 111 days 55 days 37 days 27 days
● Suitable as an onboard data logger 2 Hz 277 days 138 days 92 days 69 days
● LAN interface provided
● Analog filters are built in.
1 Hz 555 days 277 days 185 days 138 days
● Number of measuring channels: 4
● Applicable sensors:
Strain gages (4-gage bridge) Software
Strain gage transducers ● Enables the PC to set, save and read channel, measuring and
Voltage output sensors recording conditions as well as monitor measuring data and perform
● Applicable bridge resistance: 120 to 1000 Ω (4-gage bridge) data collection, data coupling, graph dispay, file conversion and
● Gage factor: 2.00 fixed environmental setting.
● Bridge excitation: 2 VDC ● PC
● Voltage measuring range: ±20 V CPU: Pentium III 700 MHz or higher
● Frequency response range: DC to 20 kHz OS: Windows 2000/XP
● Resolution of A-D conversion: 16 bits Memory: 256 MB or more
● Sampling method: Simultaneous sampling of all channels Hard disk: Blank space 10 MB or more (except for data)
● Samping frequency: 1 Hz to 100 kHz (16 steps)
● LAN interface: 10BASE-T/100BASE-TX
● Monitoring: Waveform, bar graph and numeric data can be monitored
on the PC connected via LAN.
● Data storage: Compact flash memory card (128 MB to 1 GB)
● Synchronized operation: Possible by connecting up to 8 units in
cascade with dedicated synchronous cables.
● Operating temperature/humidity range: 0 to 50 °C, 20 to 90%RH
(noncondensing)
● Vibration resistance: 49.03 m/s2 (5 G) (5 to 55 Hz) (when operating)
● Power source: 10 to 16 VDC
● Dimensions & mass: 100 x 50 x 110 mm (excluding protrusions),
approx. 500 g

15
Data Analyzers

Memory Recorder/Analyzers

Specifications of Built-in Cards (optional)


● Strain/voltage measuring card CDV-40A (compatible with TEDS)
Voltage
Item Strain measurement measurement
Number of input channels 8 (centralized connector)
Input mode Balanced input Unbalanced input
Input resistance Approx. (10 MΩ + 10 MΩ) Approx. 1 MΩ
Coupling DC/AC (DC cut)
Applicable gage factor 2.00 —
Bridge excitation 2.00 VDC ±2% (120 Ω to 1kΩ) —
Balance adjustment range Bridge resistance ±2.4% —
(±12000 µm/m)
Measuring range 500, 1k, 2k, 5k, 20k, 50k 0.1, 0.2, 0.5, 1,
µm/m, OFF 2, 5, 10 V, OFF
Range accuracy ±0.2% FS for each range
Nonlinearity ±0.1% FS
EDX-2000A-32 Frequency response range DC coupling: DC to 50 kHz, dev. +1 dB/–3 dB
AC coupling: 0.2, 1 Hz to 50 kHz
The EDX-2000A is a general-purpose extensible all-in-one instrument Lowpass filter Filter type: 2nd order Butterworth
that can measure, display, record and analyze signals sent from various Cutoff frequency: 8 steps of 10, 30, 100, 300,
connected sensors. 1k, 3k, 10 kHz and F (flat)
The maximum number of mountable channels is 32 or 64. Data Amplitude ratio at cutoff point: –3 dB ±1 dB
acquisition in 16 channels is possible at 200 kHz (32 channels at 100 Attenuation: –12 dB/oct. ±1 dB/oct.
kHz). If sensor signals of 32 channels are sampled at 10 kHz, the large- Highpass filter (DC cut) Cutoff frequency: 0.2 Hz, 1 Hz
capacity disk can store approximately 13 hours of data. Acquired and Attenuation: –6 dB/oct.
processed data can easily be transferred to the PC on or off line. In
addition, the EDX-2000A can record voice memos and if an optional DA Resolution of A-D converter 16 bits
card is used, it can perform analog reproduction of acquired digital data.
● Dynamic strain amplifier card DPM-42A (compatible with TEDS)
● Perform FFT analysis/histogram analysis while recording, thereby
For strain gages and strain gage transducers. The card uses carrier for
enabling monitoring of input signals and confirmation of analyzed
bridge excitation and thus, it is suitable for measurement of low level
results on the display.
● Optional conditioner cards can freely be mounted to configure an
strain. This card has the input and output isolated and measuring
channels isolated from each otherr.
optimum all-in-one instrument for each individual application.
● Each CDV-40A strain/voltage measuring card provides 8 channels.
Applicable sensors: Strain gages, strain gage transducers
● FFT analysis, histogram analysis and arithmetic operation possible
Number of measuring channels: 4
● Maximum sampling frequency: 200 kHz (simultaneous sampling of 16
Frequency response range: DC to 5 kHz
channels) ● Thermocouple card CTA-40A
● Easy and speedy interactive operation For temperature measurement with 2 types of thermocouples, K (CA)
● Easy-to-handle ATA card or hard disk card for data transfer to the PC and T (CC). This card has the input and output isolated and measuring
● Online data transfer to PC through LAN interface channels isolated from each otherr.
● Built-in battery against instantaneous power failure (in DC operation) Applicable sensors: Thermocouples K (CA) and T (CC)
● KYOWA standard KS2 format and the optional DAS-100A data Number of input channels: 8
analysis software are applicable to acquired data.
● F/V converter card CFV-40A
● Models
For measurement of input pulse frequency. This card has a power
Model Max. analog input channels Number of slots supply for sensors and the input and output isolated.
EDX-2000A-32 32 4 Applicable sensors: AC signal output sensors
EDX-2000A-64 64 8 Number of input channels: 4
Note: Number of slots: The number of slots for conditioner cards ● CAN card CAN-40A
For measurement of data frames on the controller area network (CAN).
● Number of input channels This card enables simultaneous recording of a maximum 16 kinds of
EDX-2000A-32: Max. 32 data frames together with usual analog data.
EDX-2000A-64: Max. 64 Number of CAN ports: 1
● Digital input: 16-bit, TTL level, contact input Connector: D-sub 9-pin for high-speed and low-speed CANs
● Voice input: 1 channel (voice memos input during measurement are Compatible CAN version: Bosch 2.0B (conforms to ISO 11898);
recorded together with measured data.) switchable between high-speed CAN and low-speed CAN
● Sampling method: Simultaneous sampling of all channels ● Charge amplifier card CCA-40A (compatible with TEDS)
● Sampling frequency: For piezoelectric accelerometers.
1 Hz to 200 kHz for data acquisition up to 16 channels Applicable sensors: Piezoelectric accelerometers
1 Hz to 100 kHz for data acquisition up to 32 channels Number of measuring channels: 8
1 Hz to 50 kHz for data acquisition up to 64 channels
1 Hz to 10 kHz when real-time analysis is performed. ● DA card DAC-40A
● Data storage capacity: 30 GB or more For analog reproduction of the data recorded with EDX-2000A.
● Built-in display: Equivalent to 10.4-inch color LCD Number of output channels: 8
● Operating keys: Key panel on mainframe and external keyboard Output voltage: ±5 V FS
● Interface: Keyboard, external display, PCMIA, LAM
● Power source: 100 to 120/190 to 240 VAC, 10 to 30 VDC
● Operating temperature/humidity range: 0 to 40 °C, 20 to 80%RH Software Specifications
(noncondensing) ● Setting measuring conditions: Measuring channel conditions,
● Vibration resistance: 29.42 m/s2 (3 G) (when operating) measuring modes, sampling frequency, number of recording data,
49.03 m/s2 (5 G) when not operating) test information and measuring conditions are set, saved and read
● Shock resistance: 196.1 m/s2 (20 G)/11 ms through the software.
● Dimensions & mass ● Types of monitoring data: Numerics, time-axis graph, bar graph
EDX-2000A-32: 350 x 132 x 300 mm (excluding protrusions), ● Relative (X-Y) graph: 1 graph/display, 2 graphs/dispay
approx. 12 kg (with 2 CDV-40A cards mounted) Each graph can be traced as 4-channel relative graph.
EDX-2000A-64: 430 x 156 x 300 mm (excluding protrusions), ● Real-time analysis: FFT analysis, histogram analysis
approx. 13 kg (with 2 CDV-40A cards mounted) Either of them is selectable during monitoring or data acquisition.

16
Data Analyzers

Data Reproduction Data Analysis Software


●Types of graph
Time-axis (X-T) graph: 1 graph/display, 2 graphs/display,
4 graphs/display
Relative (X-Y) graph: 1 graph/display; The DAS-100A enables graph display, numeric display and various kinds
8-channel relative graph of analysis of the data recorded in the KYOWA standard KS1 or KS2 file
All channel graph: Max. 64 channels/display format by KYOWA instruments including DBU-120A, PCD-300 series,
●Data file editing: Data editing, header editing, file saving, cutting, EDX-1500A, EDX-2000A, EMR-1000A and EDS-400A.
conversion to ASCII
● Enables graph display of a maximum of 8 data files.
●Statistic processing: Display and storage of maximum value,
● Enables presentation of the waveform, FFT analysis graph, statistic
minimum value, average value and standard deviation
●Analysis: Arithmetic operations, FFT analysis, histogram analysis operation results, header information, numeric list and display
conditions of a selected data file.
● Enables cutting from an acquired data file and conversion to CSV
format file.
● Statistic processing
Bridge Unit ● Arithmetic operations
● FFT analysis
● Histogram analysis
● Filtering
● Differentiation and integration
● Graph display, and readig and saving of analysis condition file
● Printer output
● Applicable data files
Data files recorded in KYOWA standard KS1 or KS2 format by DBU-
120A, PCD-300 series, EDX-1500A, EDX-2000A, EMR-1000A and
EDS-400A.
● Maximum number of applicable channels: 320
● PC
CPU: Pentium II or higher recommended
Memory: 128 MB or more
Display: 800 x 600 dots, 256 colors or more
Hard disk: Blank space 10 MB or more (except for data)
OS: Windows 2000/XP
CD-ROM drive: For installation of the DAS-100A data analysis software
PC is not provided.

The DBU-120A bridge unit is an online instrument designed to be


connected to the PC via USB interface and to be connected directly to a
strain gage or strain gage transducer. Equipped with an amplifier and A-D
converter, the DBU-120A comes standard with the control software
which enables the PC to operate the DBU-120A and to perform data
acquisition. The unit is supplied with power through USB interface, and
thus requires no special power source.
● While designed for 1-channel measurement, up to 4 units can be
connected to the PC for simultaneous 4-channel measurement.
● Maximum sampling frequency: 20 kHz
● NDIS connector enables simple one-touch sensor connection.
● Control software is included in standard accessories.
● Optional DAS-100A analysis software enables data analysis.
● Applicable sensors: Strain gages, strain gage transducers, voltage
output sensors
● Applicable gage resistance
120 Ω to 1 kΩ (120 Ω only for 1-gage system)
● Bridge excitation: 0.5, 2, 5 V
● A-D conversion: 16 bits
● Sampling frequency: 1 Hz to 20 kHz
● Range
Strain: 1k, 10k, 100k µm/m
Voltage: 10 V
● Lowpass filter cutoff frequency: 10, 30, 100, 300 Hz and FLAT
● Frequency response range: DC to 1 kHz
● Interface: USB 1.1
● PC
CPU: Pentium III 700 MHz or higher
OS: Windows XP/2000
Memory: 192 MB or more
Hard disk: Blank space 10 MB or more (except for data)
● Dimensions & mass: 90 x 35 x 144 mm (excluding protrusions),
approx. 350 g

17
Instrumentation Amplifiers & Related Instruments

Instrumentation Amplifier Small-Sized Digital Indicator

● Number of measuring channels: 1 ● Number of measuring channels: 1


● For strain gage transducers ● For strain gage transducers
● Connectable in parallel up to 4 transducers of 350 Ω bridge resistance ● Pocketable size
● Peak hold function and D-A output function provided standard ● Applicable transducers: 4-gage system,
● Model with BCD data output or RS-232C is also available. 60 to 1000 Ω
● Comparator function based on preset high/low limits. ● Input range: 0 to ±10000 µm/m
● Measuring range: ±3.2 mV/V ● Original mode: Indication in µm/m or mV/V
● Bridge excitation: 10, 2 VDC ● Indication in engineering unit is available through
● Display: ±19999 calibration by numeric input.
● Sampling rate: 2000 times/sec ● Digital zero correction possible
● Frequency response : DC to 100 Hz ● Power source: Size AA battery x 2
● Nonlinearity: Within ±(0.03%FS + 1 digit) ● Dimensions & mass: 66.5 x 92 x 28 mm
● Stability (excluding protrusions), approx. 150 g
Zero: Within ±0.25 µVRTI/°C
Sensitivity: Within ±0.01%/°C
● Continuous peak hold function
● EMC standard: EN61326-1 (class A)
● Safety standard: EN61010-1
(installation category II, pollution degree 2)
● Power source: 100 to 240 VAC ±10%; 20 VA or less
● Dimensions & mass: 96 x 96 x 139 mm (excluding protrusions),
Weighing Checker
approx. 1.1 kg
● Number of measuring channels: 1
● Enables easy field inspection of load cell-applied
Instrumentation Amplifier measuring system.
● Applicable transducers: Strain gage transducers (60 to 350 Ω)
● Strain output: 0 to ±2000 µm/m (17 ranges)
● Measuring range
● Number of measuring channels: 1
Resistance: 0 to 1999 Ω
● For strain gage transducers
Strain: ±1999 µm/m (x1 range)
● Connectable in parallel up to 4 transducers of ±19990 µm/m (x10 range)
350 Ω bridge resistance ● Insulation resistance check: 1 to 100 MΩ
● Excellent noise resistance makes it suitable ● Power source: Size AA battery x 2
for incorporation into industrial equipment. ● Dimensions & mass: 92 x 182 x 25 mm
● Varieties of built-in functions extend the
(excluding protrusions), approx. 600 g
application field.
● Comparator function based on preset high/
low limits (1 relay contact outplut transfer
circuit) and peak hold function
● Setting parameters are stored in nonvolatile
memory against power failure.
● Measuring range: ±3.2 mV/V
● Display: ±9999
● Selectable functions
BCD data output Static Strain Meter
Analog conditioner
D-A converter
RS-232C
Isolated analog conditioner ● Compact and lightweight design suitable for carrying to
8-step comparator the field
● Power source: 100/115/200/220 VAC (Select one.) ● Besides strain measurement, insulation resistance
● Dimensions & mass: 72 x 144 x 188 mm (excluding protrusions), can be checked.
approx. 1.7 kg ● Number of measuring channels: 1
● Applicable sensors
Strain gage transducers (60 to 1000 Ω)
Strain gages
Instrumentation Amplifier 1-gage system, 120 Ω
2-gage system, 60 to 1000 Ω
4-gage system, 60 to 1000 Ω
● Measuring range: 0 to ±19999 µm/m
● Number of measuring channels: 1
● Dimensions & mass: 90 x 33 x 180 mm
● For strain gage transducers
● Connectable in parallel up to 4 transducers
(excluding protrusions), approx. 450 g
of 350 Ω bridge resistance
● Compact, lightweight, low cost, and
high-performance capability
● Suitable for incorporation into industrial equipment
● 2 types are available, manual balance system and
auto-balance system.
● Simultaneous output of voltage and current
● Rated output: ±10 V, 4 to 20 mA
● Power source: 100/200 VAC, 10 to 30 VDC
(Select one.)
● Dimensions & mass: 44 x 90 x 101 mm (excluding
protrusions), approx. 400 g
● EMC standard: EN50081-2, 50082-2
● Safety standard: EN61010-1

18
Automotive Test Equipment

Thin Pedal Force Transducers Wheel 6-Component Force Measuring System


LPR-A, B ●The sensing part uses no slip ring, and thus ensures easy installation
●Thin and lightweight design with minimal error due to leg-power with virtually no protrusion outside the wheel.
application method ●The sensor part is thin and lightweight and is designed like a practical
●Rated capacity wheel.
LPR-A: 300 N to 2 kN ●The sensor part transmits detected signals to the onboard memory
LPR-B: 500 N to 2 kN recorder/analyzer in PCM multiplex telemetry system.
●Nonlinearity ●The onboard memory recorder/analyzer
LPR-A: Within ±0.5% RO corrects interfrence and angle and then
LPR-B: Within ±1% RO records the data, while monitoring the
●Hysteresis real-time data in graph or numeric format.
LPR-A: Within ±0.5% RO ●Large-capacity memory enables
LPR-B: Within ±1% RO long-term data acquisition.
●Rated output ●Enables recording of various data by
LPR-A: 1 mV/V or more suddenly starting, abruptly braking,
LPR-B: 0.5 mV/V or more stopping and driving backward and
●Safe overload rating: 150% forward.

Door Window Torque Transducer

●Simultaneously and accurately measures the operating force and angle


Wheel Torque Transducer
of the door window regulator. ●Measures the wheel torque of running vehicle.
●Mounted through the adapter designed to ●Can measure the drive and control torque while running the vehicle.
the testing vehicle ●Since the transducer is manufactured to the regular wheel design, it
●Rated capacity can easily be mounted and used in an optimum condition.
Torque: ±8 N.m ●Rated capacity: As specified
Rotation angle: ±10 rotations ●Nonlinearity: Within ±0.5% RO
●Nonlinearity: Within ±0.5% RO ●Hysteresis: Within ±0.5% RO
●Hysteresis: Within ±0.5% RO ●Rated output: Approx. 1 mV/V
●Rated output: Approx. 1 mV/V ●Rotation speed: Max. 1500 rpm
●Safe overload rating: 120%
(Rotation angle is mechanically endless.)

Change Lever Operating Force Transducer

● Measures the 2-component force initiated by Telemetry Wheel Torque Transducer


operating the floor shift change lever.
● Measures the wheel torque of running vehicle.
● Rated capacity: 200, 300 N
● Suitable for wheel control tests and traction control tests.
● Nonlinearity: Within ±0.5% RO
● Thin and lightweight sensor is mounted with minimal protrusions
● Hysteresis: Within ±0.5% RO
● Rated output: Approx. 0.5 mV/V (for both Fx and Fy) outside the body.
● Signal transmission in telemetry system
● Safe overload rating: 120% (for both Fx and Fy)
● Unique design with no slip ring facilitates
● Interference: ±5% RO (between Fx and Fy )
● Mass: Approx. 100 g installation to the vehicle.
● Rated capacity: 2.5 kN.m (other rated
capacity is available on request.)
● Nonlinearity: Within ±0.5% RO

Hand Brake Force Transducer


Miniature Crash Test Acceleration Transducer
● Measures hand brake tension.
● Rated capacity: 500 N, 1 kN
● Nonlinearity: Within ±1% RO
● Hysteresis: Within ±1% RO ●For crash test dummies and car bodies
● Rated output: 1 to 2 mV/V ●Rated capacity: ±9807 m/s2
● Safe overload rating: 120% ●Nonlinearity: Within ±0.5% RO
● Mass: Approx. 800 g ●Hysteresis: Within ±0.5% RO
●Rated output: 1.2 mV/V or more
●Safe overload rating: 200%
●Frequency response range: DC to 4 kHz
●Mass: Approx. 1 g
Steering Force/Angle Transducer ★ This product falls under export regulations.

● Accurately measures the force and angle of operating steering wheel. Miniature Semiconductor Acceleration Transducer
● Applicable without any remodelling of the vehicle
● Rated capacity ASM-1KBCV/BCH M3
Steering force: 50 to 200 N.m ● Applicable to crash test car bodies
Steering angle: ±1 to 6 turns ● Rated capacity: ±9807 m/s2
● Nonlinearity: Within ±0.5% RO
● Nonlinearity: Within ±1% RO
● Hysteresis: Within ±0.5% RO
● Hysteresis: Within ±1% RO
(Backlash of steering angle: ● Rated output: 1.75 mV/V or more
Within ±0.5% RO) ● Safe overload rating: 150%
● Rated output: 1 to 2 mV/V
● Frequency response range: DC to 2.8 kHz
(for both steering force and angle) ● Mass: 4.0 g ±0.5 g
★ This product falls under export regulations.

19
Automotive Test Equipment

Seat Belt Tension Transducer Crash Test Analysis Software


This software enables the PC to analyze crash test data in accordance
with the test standards in Japan, US and Europe. Crash tests are
● Measures tension applied to the seat belt by the crushed dummy. performed with sensors applied to the head, chest, abdomen and other
● Rated capacity: 20 kN
parts of a dummy to measure crash-initiated acceleration, displacement
● Nonlinearity: Within ±2% RO
and load. Signals of these sensors are recorded by KYOWA DIS series
● Hysteresis: Within ±2% RO
onboard data acquisition systems and transferred to the PC. The PC filters
● Rated output: Approx. 2.5 mV/V
and processes the data to calculate injury values. Major test methods are
● Safe overload rating: 100%
frontal impact test and side impact test. Dummies mounted in test vehicles
include Hybrid III, side impact dummy and child dummy. This software can
analyze data obtained through all these test methods and dummies.

Barrier Matrix Test Data Analysis Software


This software enables the PC to analyze the data obtained by colliding a
test vehicle against the force sensor matrix. DIS series data acquisition
systems are connected to the force sensor matrix to analyze the data.
Steering 3-Component Force Transducer The software also enables the PC to graphically display the data together
with video images photographed during testing.

● Simultaneously measures 3 orthogonal force components Dummy Qualification Software


to the steering.
● Minimal interference between channels With dummies used for automotive crash and safety tests, laws and
● Rated capacity: 20 kN (for each of Fx, Fy and Fz) regulations require qualification for each of the head, neck, chest, leg,
● Nonlinearity: Within ±1% RO etc. of every type and structure.
● Hysteresis: Within ±2% RO For the qualification of a dummy, prescribed shock and load are applied to
● Rated output: Approx. 1.5 mV/V the test site through the tester and the corresponding response is recorded as
(for each of Fx, Fy and Fz) the data of the dummy mounted sensor and the qualification tester mounted
● Interference between channels: sensor. The acquired data is processed by the proper digital filter defined for
5% RO or less. the type of qualification. Then, the waveform is operated to calculate the
analyzed value, which is checked against the reference value for qualification.
This software enables indication of the reference value for qualification on the
acquired data waveform and the calculated data waveform.
The software is applicable to the qualification of various dummies for
frontal collision, side collision and child. Criterion for determining the
reference value for qualification is compatible with laws and regulations in
Japan, US and Europe.
Onboard Crash Test Data Acquisition System
Child Seat Dynamic Test Analysis Software
● Highly shock-resistant, compact and lightweight (the volume is one- This software enables the PC to analyze the results of dynamic test
fourth of the KYOWA foregoing product) (impact-applied safety evaluation test) of child seat in accordance with
● While the single unit provides 32 channels, multiple units can be the test standard. For test data acquisition, DIS series onboard data
distributedly set in a vehicle. acquisition system can be used. The dynamic test is performed using the
● Built-in battery enables measurement without any external power supply. thread impact tester. The child seat with a child dummy is mounted on
● Large-capacity flash memory enables 50-second data acquisition with the test seat placed on a dolly. The dolly is driven at a speed of 50 km/h
a sampling frequecy of 20 kHz. and is accelerated and decelerated in a prescribed range to record
● Ethernet interface (10BASE-2) is adopted. resultant signals. This software enables the PC to calculate injury values
● In addition to signals of strain gages, of the child dummy by analyzing the acquired data. The analyzed results
semiconductor gages and transducers, are displayed and printed in graphs together with injury values.
the system can measure voltage
and digital signals.
● The PC is used as the controller.
● Simultaneous measurement with the
DIA-312A airbag timer is possible.
● An emergency brake system is
available to stop the test vehicle upon
crashing.

Force Sensor Matrix (128 Cells)


Mounted to a fixed barrier wall, the force sensor matrix detects the
impact load applied by the test vehicle when it collides against the barrier
wall. The matrix consists of 128 force sensors arranged in 8 columns by
16 rows to enable measurement of the load distributed on the collided
surface. The load detecting direction is vertical to the barrier wall. Each
Traffic System
force sensor has a rated capacity of 300 or 500 kN.
Portable Truck Weighing System
Series
●Enables easy and accurate measurement of wheel load, axle load,
total weight and left-right weight balance.

Detector Indicator

20
Civil Engineering/Construction Instruments

Guide Roller-Equipped Inclination Transducer Pore Pressures Transducer


BPB-A/BPB-A-T
●The inclination transducer can be installed at up to 15 ●The small outer diameter of 30 mm enables installation of these pore
stages in the guide pipe. pressure transducers in a small boring.
●No grouting work required in the guide pipe ●Flat filter attached
●Rated capacity: ±5°, ±10° ●Enclosure is made of stainless steel.
●Nonlinearity: Within ±0.5% RO ●Rated capacity: 200 kPa to 2 MPa
●Hysteresis: Within ±0.5% RO ●Temperature measuring range: –30 to 70 °C (BPB-A-T)
●Rated output: 1.4 mV/V or more ●Nonlinearity: Within ±1% RO (within ±2% RO with 200KP)
●Hysteresis: Within ±1% RO
●Rated output: 1 mV/V or more
(0.75 mV/V or more with 200KP)
Hollowed Load Cells
BL-B, E
●For measurement of load applied to an earth anchor or the support of
tunnel arch
●Rated capacity
BL-B: 5 to 500 kN
Pore Pressure Transducers
BL-E: 1, 2 MN BPC-A/BPC-A-T
●Nonlinearity: Within ±2% RO
●Hysteresis: Within ±1% RO ●The double enclosure structure eliminates any effect of lateral
●Rated output: 1 mV/V or more pressure.
●Flat filter attached
●Exterior parts are made of stainless steel.
●Rated capacity: 200 kPa to 2 MPa
Strain Transducers ●Temperature measuring range: –30 to 70 °C (BPC-A-T)
●Nonlinearity: Within ±1% RO
BS-AT, BT (within ± 2% RO with 200KP)
●For measurement of strain occurring inside concrete ●Hysteresis: Within ±1% RO
●Rated capacity ●Rated output: 1 mV/V or more
BS-AT: ±500 µm/m (0.75 mV/V or more with 200KP)
BS-BT: ±1000 µm/m
●Temperature measuring range: –30 to 70 °C
●Nonlinearity
BS-AT: Within ±1.5% RO
BS-BT: Within ±2% RO
●Hysteresis: Within ±2% RO Highly-Sensitive Pore Pressure Transducer
●Rated output
BS-AT: ±1 mV/V or more
BS-BT: ±0.5 mV/V or more ●High sensitivity (4000 µm/m) and high accuracy (±0.5% RO)
●Excellent thermal stability (±0.02% RO/°C)
●Cone filter attached
Surface-Mounting Strain Transducer ●Rated capacity: 200, 500 kPa
●Nonlinearity: Within ±0.5% RO
●Hysteresis: Within ±0.5% RO
●Formeasurement of strain occurring on the surface of steel and ●Rated output: 2 mV/V or more
concrete
●Rated capacity: ±2000 µm/m
●Temperature measuring range: –30 to 70 °C
●Nonlinearity: Within ±2% RO
●Hysteresis: Within ±2% RO
●Rated output: ±0.625 to 1.25 mV/V
Small-Sized Pore Pressure Transducer

●Small-sized (outer diameter: 20 mm) and small capacity


Stress Transducer ●Rated capacity: 50 to 200 kPa
●Nonlinearity: Within ±1% RO (within ±2% RO with 50KPS)
●Hysteresis: Within ±1% RO
●Rated output: 0.4 to 1.2 mV/V
●For concrete stress measurement
●Rated capacity: 2 to 10 MPa
●Temperature measuring range: –30 to 70 °C
●Nonlinearity: Within ±1% RO
●Hysteresis: Within ±0.5% RO
●Rated output: ±1 mV/V or more

Small-Sized Pore Pressure Transducer


Reinforcing-Bar Stress Transducer
● Small-sized
(outer diameter: 10 mm) and suitable for indoor model
experiments
●Stress on reinforcing bar is measured by welding both ends of this ● Short-term embedded applicationis possible.
transducer to the bar. ● Rated capacity: 200, 500 kPa
●Rated capacity: 300 MPa ● Nonlinearity: Within ±1% RO
●Temperature measuring range: –30 to 70 °C ● Hysteresis: Within ±1% RO
●Applicable reinforcing bar: SD345 ● Rated output: 0.8 mV/V ±2.5%
●Deformed reinforcing bar: D10 to D32
●Nonlinearity: Within ±1% RO
●Hysteresis: Within ±1.5% RO
●Rated output: 1.85 mV/V or more

21
Civil Engineering/Construction Instruments

Water Level Transducer Crack Displacement Transducer


BWL-ET
● For measurement of fluctuation of underground water level ●For measurement of crack occurring on rock bed, etc.
● Lightning arrester element built in. Atmospheric pressure ●Small measuring force enables installation
compensated to soft rock bed.
● Rated capacity: Water level 0 to (10, 20, 30) m ●Rated capacity: ±5 mm
● Temperature measuring range: –20 to 60 °C ●Nonlinearity: Within 2% RO
● Nonlinearity: Within ±0.15% RO ●Hysteresis: Within ±2% RO
● Hysteresis: Within ±0.1% RO ●Rated output: ±1 mV/V ±5%
● Rated output: 2 mV/V or more ●Measuring force: Approx. 9.8 N/5 mm
● Stainless steel structure of 32 mmφ by 122 mm long

Crack Transducer
Temperature Transducer
●For measurement of internal crack of concrete
●Rated capacity: 0 to (5 to 50) mm
●Measuring temperature range: –30 to 70 °C
● For embedded application (hydraulic pressure resistance: 200 kPa) ●Nonlinearity: Within 1.5% RO
● Rated capacity: –30 to 70 °C
●Hysteresis: Within ±1.5% RO
● Resolution: 0.01 °C
●Rated output: 1 mV/V or more
● Measuring error: ±0.3 °C
● Output: 50 µV/V/°C
● Mass: Approx. 120 g

Soil Pressure Transducers

Small-Sized Temperature Transducer ●Cable is attached in parallel to the sensing diaphragm.


●Diameter of the sensing diaphragm and rated capacity

Model Diam.* Rated capacity


● The diameter is as small as 5 mm.
● Embedded application possible for model experiments BEC-A 23 200k to 1 MPa
and short-term measurement BEE-A 160 200k to 2 MPa
● Connected to an amplifier constant-current bridge BEM-A 80 50k to 1 MPa
excitation type for measurement
BEN-A 70 500k, 1 MPa
● Rated capacity: –30 to 70 °C
● Measuring error: ±0.5 °C BEU-A 46 200 kPa
● Mass: Approx.10 g BEG-A 600 200k to 2 MPa
*Diameter of sensing diaphragm in mm

Soil Pressure Transducers


Joint Transducer ●Cable is attached at right angle to the sensing diaphragm.
●Diameter of the sensing diaphragm and rated capacity

● Formeasurement of an opening degree of joint, such as between Model Diam.* Rated capacity
concrete blocks BED-A 23 200k to 1 MPa
● Crack of rock-bed can be measured. BEF-A 160 200k to 2 MPa
● Rated capacity: 0 to (5 to 50) mm
● Temperature measuring range: –30 to 70 °C
BEB-H 60 50k to 1 MPa
● Nonlinearity: Within ±1.5% RO *Diameter of sensing diaphragm in mm
● Hysteresis: Within ±1.5% RO
● Rated output: 1 mV/V or more

Wall-Surface Soil Pressure Transducers


BER-A-12S, 15S, 17S, 58S, 110S
● Load cell type design receives no bending effect of structure.
● Cable is attached at right angle or in parallel to the sensing diaphragm.
Concrete Surface Displacement Transducer ● Diameter of the sensing diaphragm and rated capacity

Model Diam.* Rated capacity


● Easy installation using a fixture and adhesive BER-12S 73 100k to 5 MPa
● Reusable
BER-15S 24.5 500k to 5 MPa
● Rated capacity
Tension: 2% strain or less (0 to 1.40 mm) BER-17S 24.5 500k to 5 MPa
Compression: 0.5% strain or less (0 to 0.35 mm) BER-58S 73 500k to 5 MPa
● Nonlinearity: Within ±3% RO BER-110S 95 100k to 5 MPa
● Hysteresis: Within ±3% RO
*Diameter of sensing diaphragm in mm
● Rated output: Approx. 2.5 mV/V

22
Specifications are subject to change without notice for improvement.

Safety precautions Be sure to observe the safety pre-


cautions given in the instruction
manual, in order to ensure correct
and safe operation.

Reliability through integration ,


Manufacturer s Representative

KYOWA ELECTRONIC INSTRUMENTS CO., LTD.


Overseas Department:
1-22-14, Toranomon, Minato-ku, Tokyo 105-0001, Japan
Tel: (03) 3502-3553 Fax: (03) 3502-3678
http://www.kyowa-ei.com
e-mail: [email protected]
Cat. No. 901G-U62 Printed in Japan on Recycled Paper 09/05 ocs

You might also like