250-KYOWA SF Catalog
250-KYOWA SF Catalog
MEASURING
INSTRUMENTS
2005∼2006
★Strain Gages
★Load Cells
★Pressure Transducers
★Acceleration Transducers
★Torque Transducers
★Displacement Transducers
★Dynamic Strain Amplifiers
★Data Loggers
★Data Analyzers
★Instrumentation Amplifiers & Related Instruments
★Automotive Test Equipment
★Traffic System
★Civil Engineering/Construction Instruments
Strain Gages
● Superior flexibility, and outstanding moisture proofness requiring no ● Usable either outdoors or underwater (100
coating treatment unless splashed directly with water. hours or more under 10MPa in water)
● All models are equipped with leadwire cable. ● Gage length: 2, 5 mm
● Improved characteristics ● Gage pattern: Uniaxial, biaxial 0°/90°, triaxial
Operating temperature range: –196 to 120°C (when bonded with CC- 0°/90°/45° (triaxial is available only for KFW)
33A), –196 to 150°C (when bonded with PC-6) ● Applicable linear expansion coefficient:
High performance: Self-temperature-compensation of ±1.0 µm/m/°C at 11, 16, 23 x10–6/°C
normal temperatures and capability of measurement up to strain limit of ● Resistance: 120, 350 Ω (KFWS: 120 Ω only)
5% (uniaxial)
● Gage length: 0.2, 0.3, 1, 2, 3, 4, 5, 6, 10, 20, 30 mm
● Gage pattern: Uniaxial, biaxial, triaxial, quadraxial, uniaxial 5-element, Weldable Waterproof Foil Strain Gages
biaxial 5-element
● Applicable linear expansion coefficient: 5, 11, 16, 23, 27 x10–6/°C
● Leadwire cable: Polyester-coated copper wires (2 to 100 cm), vinyl- ● Available in 2 types: Uniaxial 1-element G10 and full-bridge G14S
coated cable (15 cm to 30 m), middle temperature cable (15 cm to 30 m) ● Welding type requires no coating treatment.
● Applicable adhesive: Cyanoacrylate CC-33A ● Flange size: 5 x 21 mm, t = 0.1 mm
● Applications: General stress measurement, stress analysis, torque ● Applicable linear expansion coefficient: 11 x10–6/°C
measurement, fine wire, shearing stress, concentrated stress ● Operating temperature range: –20 to 100°C
(uniaxial/biaxial 5-element)
● Resistance: 60, 120, 350, 500, 1000 Ω
Biaxial 0°/90° Biaxial for torque Foil Strain Gages for Composite Materials
2
Strain Gages
Gage Terminals
● To protect gage leads, gage terminals are applied to the connection
between strain gages and leadwires. They are available in various
materials and shapes.
3
Load Cells
4
Load Cells
● Compact, lightweight, and easy to use and maintain ● Compact, lightweight and low cost
● Rated capacity: 500 N to 50 kN ● Metal bellows adopted
● System accuracy: Within ±0.03% RO ● Rated capacity: 50 N to 20 kN
(within ±0.05% RO with 500KA or larger) ● System accuracy: Within ±0.03% RO
● Nonlinearity: Within ±0.03% RO (within ±0.05% RO with 500KA or larger) (within ±0.05% RO with 100KB or larger)
● Hysteresis: Within ±0.03% RO (within ±0.05% RO with 500KA or larger) ● Nonlinearity: Within ±0.03%RO
● Rated output: 3 mV/V ±0.2% (within ±0.05% RO with 100KB or larger)
● Safe overload rating: 150% ● Hysteresis: Within ±0.03% RO (within ±0.05% RO with 100KB or larger)
● Rated output: 2 mV/V ±0.3%
● Safe overload rating: 150%
5
Load Cells Pressure Transducers
6
Pressure Transducers
7
Acceleration Transducers
8
Torque Transducers
● No contact part such as slip ring or bearing ● For small torque measurement
● Suitable for use at high-speed revolutions ● Equipped with overload prevention stopper
● Rated capacity: ±500 N.m to 50 kN.m ● Rated capacity: 0.2 to 5 N.m
● Nonlinearity: Within ±0.2% RO ● Nonlinearity: Within ±0.2% RO
(within ±0.5% RO with 1TMA or larger) ● Hysteresis: Within ±0.2% RO
● Hysteresis: Within ±0.2% RO ● Rated output: 0.75 to 1.5 mV
(within ±0.5% RO with 1TMA or larger) ● Safe overload rating: 150% (stopper
● Rated output: ±10 V, 4 to 20 mA operates at 150%.)
● Safe overload rating: 150% ● Maximum speed: 3000 to 15000 rpm
(120% with 1TMA or larger)
(Output is saturated at 110%.)
● Maximum speed: 3000 to 10000 rpm
TP-CB
TPN-CB
TP-E
RBE-E
9
Displacement Transducers
● Compact, lightweight, highly accurate and high output level ● For large displacement measurement
● Rated capacity: 5 to 100 mm ● Compact, lightweight and high output level
● Nonlinearity: Within ±0.1% RO ● Rated capacity: 500 to 5000 mm
● Hysteresis: Within ±0.1% RO ● Nonlinearity: Within ±0.3% RO
● Rated output: 5 mV/V ±0.1% ● Hysteresis: Within ±0.3% RO
● Measuring force: Approx. 1.5 to 4 N ● Rated output: 5 mV/V ±0.3%
● Measuring force: Approx. 0.98 to 1.67 N
● Safe overload rating: 120%
● Flexible steady point type is available.
DTP-D-5KS
DTP-D-500S
DTP-D-2KS
Displacement Transducer
Displacement Transducers
Clip Type Displacement Transducers
● Direct-reading scale provided
● Rated capacity: 50, 100 mm
● Nonlinearity: Within ±0.5% RO ● For materials tests, with overload prevention stopper
● Hysteresis: Within ±0.5% RO ● Mounting chip is optionally available.
● Rated output: 1.5 mV/V ±20% ● Rated capacity: 2, 5 mm
● Measuring force: Approx. 4.4 N ● Nonlinearity: Within ±1% RO
● Hysteresis: Within ±1% RO
● Rated output: 2.5 mV/V +20%/–10%
● Safe overload rating: 130%
DTC-A-5
DTC-A-2
Dial Gage Displacement Transducers
10
Dynamic Strain Amplifiers
Multi Conditioners
● For optimum system configuration, various cards are available Monitor Card DPE-71A
including dynamic strain, signal conditioner, F-V converter, charge Speifications Common to All Conditioner Cards
amplifier and thermocouple. ● Number of measuring channels: 1
● All conditioner cards have the input and output isolated.
● Output: 2-way output (the same voltage is output to the BNC
● Excellent vibration resistance enables onboard application.
connector and centralized connector.)
● 8 and 16-channel unit bases are available for configuration of desire
Output voltage: ±5 V (5 kΩ load or more)
multichannel configuration.
● Dynamic strain amplifier card is provided with true electron type auto- ● Dynamic Strain Amplifier Cards DPM-71A/72A
balance system and with the CST system which cancels capacitive Model Frequency response range Carrier
unbalance by constantly tracking capacitive component.
● Input/output isolation system ensures high noise resistance and safety. DPM-71A DC to 2.5 kHz (deviation ±10%) 5 kHz
● Conforming to CE marking DPM-72A DC to 5 kHz (deviation ±10%) 12 kHz
Unit Bases MCD-8A/16A
● Models ● SignalConditioner Card CDV-71A
MCD-8A: To accommodate 8 conditioner cards
MCD-16A: To accommodate 16 conditioner cards ● Thermocouple Card CTA-71A
● Vibration resistance: 49.03 m/s2 (5 G) (5 to 55 Hz) ● F-V Converter Card CFV-71A
● Power source: 100 to 240 VAC, 9 to 18 VDC
● Charge Amplifier Card CCA-71A
● Dimensions & mass
MCD-8A: 264 x 132.5 x 300 mm (excluding protrusions),approx. 7 kg
MCD-16A: 426 x 132.5 x 300 mm (excluding protrusions), approx. 10 kg
● EMC standard: EN 61326-1 (common to all cards)
● Safety standard: EN 61010-1 (Installation category II, Pollution level 2)
11
Data Loggers
Data Loggers
UCAM-60A, 65A
Data Loggers UCAM-60A/65A
●Sensors and connectable scanners
External scanner
scanner
Internal
General purpose Civil engineering
Scanner
USB- USB- USB- USB- USB- USB-
Sensor 70A/B- 51A 51AT 20A/ 70A/B- 50D
10/20 50A 30
Strain gages & strain gage transducers
1-gage system
120 Ω
240 Ω
350 Ω
1-gage true dummy system
120 Ω
350 Ω
PC is not included.
2-gage system, 60 to 1000 Ω
Active-dummy method
The UCAM-60A data logger is an all-in-one instrument developed in full Active-active method
pursuit of easy handling in the field. The instrument is provided with all Common dummy method
functions required for measurement in the field, including easy-to-use 4-gage system, 60 to 1000 Ω*3
keys, bright readable display and printer for immediately confirming Opposite side active method
measured results. The UCAM-65A is an online version wholly controlled Full-bridge method
by the PC. Civil engineering transducers
Both models can measure up to 30 channels of data with the mainframe 4-gage system, 120 Ω
only, while external scanners enable measurement in up to 1000 Constant-current excitation
channels. Measured results are stored in internal memory and are saved 4-gage system, 350 Ω
in a flash ATA card if inserted in the PC card slot for offline data transfer Constant-current excitation
to the PC. In addition, the UCAM-60A and UCAM-65A are provided with With temp. measuring function
Ethernet and RS-232C ports which enable the PC to not only control Voltage output sensors (DC) *4
these data loggers through the control software UCS-60A but also Temperature
process data for rosette analysis, etc. in the field by directly receiving Thermocouple K (CA) *4
data. T (CC) *4
E (CRC) *4
J (IC) *4
UCAM-60A R
● Fluorescent display tube ensures easy observation in the field. *4
Platinum resistance thermometer sensor
● Built-in thermal printer enables immediate confirmation of measured
Pt100 (new JIS)
results. JPt100 (old JIS)
● Control
software UCS-60A (optional for UCAM-60A) can place the Potentiometer sensors
UCAM-60A under the control of the PC connected through Ethernet or Built-in lightning arrester
RS-232C port. *1
Scanner interface (USI-)*2 Not
required -67A -65A -67A -65A
UCAM-65A Notes: 1. With USS-63A mounted
● Withthe UCAM-65A, measuring conditions, etc. are set from the PC 2. Use either of the scanner interfaces for connection to external scanners.
and measured results are transferred to the PC. 3. 120 to 1000 Ω with high-resolution mode
● Can be used for interval measurement as a stand-alone unit with no 4. With the UST-10 temperature measuring unit mounted
PC connected. ● Number of measuring channels:
Max. 30 with dedicated scanners
Common to UCAM-60A and UCAM-65A Max. 1000 with external scanners
● Can measure up to 20000 µm/m with a resolution of 0.1µm/m. Max. 1000 with internal scanners plus external scanners
● Scanning speed:
● Scanning at 50 ms/channel
● High-speed scanning at 20 ms/channel is possible.
50 ms/channel (standard mode)
280 ms/channel (high-resolution mode)
● DC-operated version is available for operation where no AC outlet
is (Can be set for every channel.)
available. 20 ms/channel (high-speed mode)
● Configuration (Can be set for every channel.)
Mainframe: UCAM-60A ● PC card slot: Conforms to PCMCIA Ver. 4.2.
UCAM-65A Accepts commercially available flash ATA card.
Dedicated scanners mounted to mainframe: ● Interface: RS-232C, Ethernet (10BASE-T/100BASE-TX)
USS-61A ● Operating temperature & humidity range: 0 to 50 °C, 20 to 85%RH
USS-62A (with NDIS connectors) (noncondensing)
USS-62A M6 (with clamp-style terminal board and NDIS connectors) ● Power source: 85 to 264 VAC, 50/60 Hz (AC version)
USS-63A (with lightning arrester) 10 to 16 VDC (DC version)
Note: A dedicated scanner is provided with 10 channels and up to ● Dimensions
3 units can be mounted to the mainframe. UCAM-60A: 360 x 88 x 400 mm (excluding protrusions)
External scanners UCAM-65A: 327 x 88 x 365 mm (excluding protrusions)
● Mass: Approx. 8 kg (60A), 4.6 kg (65A)
USB-70 series (USI-67A scanner interface required)
USB-51A/51AT (USI-65A scanner interface required)
USB-20A/50A (USI-65A scanner interface required)
USB-50D (USI-65A scanner interface required) Control Software
Scanner interfaces
USI-67A for USB-70 series
USI-65A for USB-20/50/51 series The software enhances the performance of the data logger by letting the
External input/output unit UIO-60A PC present measured results in graphic and numeric formats as well as
Control software UCS-60A perform data analysis.
● Controls UCAM-60A, 65A, 20PC and 500A.
● Enables presentation of numeric list on the PC.
● Enables presentation of maximum 4 graphs at a time on the PC.
● Arithmetic operations, statistic operation and rosette analysis
● Reading and storage of measuring and calculating condition files
● PC
CPU: Pentium III 450 MHz or higher or the equivalent
OS: MS-Windows 98/98SE/Me/2000/XP
Memory: 256 MB or more
Hard disk: 10 MB or more (excluding data)
12
Data Loggers
This system consists of USB-500A scanner, UCAM-500A controller and ● Frequency response range: DC to 7.8 Hz (deviation: 0.5 to –3.5 dB)
the PC in which the UCS-500A control software is installed. The USB-500A ● Interface
performs multichannel measurement at high speed. The UCAM-500A Dedicated interface between controller and scanner and between
quickly records the measured data. The UCS-500A-installed PC sets, scanner and scanner
controls and operates the system for measurement and data acquisition. Dedicated interface cable: 2 m long (Each scanner is provided with
The scanner and controller are black box type with no operating part. one interface cable.) Total extensible length: Up to 185 m
The measuring speed ranges from 1000 channels/(1 time/sec) to 100 ● Operating temperature/humidity range: 0 to 40 °C, 20 to 85%RH
channels/(50 times/sec) and such high-speed measurement enables the (noncondensing)
system to cope with a wide range of phenomena from static to quasi- ● Power source: 85 to 264 VAC (no switchover required), 50/60 Hz;
dynamic. approx. 50 VA
Since the input accepts strain, voltage and temperature, the system can ● Dimensions: 426 x 133 x 300 mm (exluding protrusions)
measure signals from strain gages, strain gage transducers, potentiometer ● Mass: Approx. 6.5 kg (with five USS-51A strain units mounted)
sensors, voltage output sensors and thermocouples.
● Number of measuring channels: Max. 1000. Flexibly coping with Strain Unit USS-51A
measurement in small to large scale. ● Number of measuring channels: 10/unit
● Simultaneous sampling of all channels, ensuring simultaneity of data. ● Applicable sensors: Strain gages, strain gage transducers,
● Can measure static to quasi-dynamic phenomena (DC to several Hz). potentiometer sensors
● High-speed, large-capacity semiconductor memory enables long-term ● Bridge excitation: Constant voltage of 2 VDC (constantly applied)
data acquisition. ● Potentiometer excitation: Constant voltage of 2 VDC (constantly
● Control software operates on Windows 95/98/98SE/Me. applied)
● Arithmetic operations and data processing with built-in functions for ● Gage factor: 2.00 fixed (correctable with 2.00/Ks through the use of the
rosette analysis, etc. engineering unit conversion function)
● Wholly operated through the PC. ● Measuring range, resolution and accuracy (with static DC input)
13
Data Analyzers
Sensor Interfaces
Series
PC is not provided.
The PCD-300 series sensor interfaces make the existing PC a versatile PCD-300A
measuring instrument. The PCD-300A enables the PC to perform stress ● Applicable sensors: Strain gages, strain gage transducers
measurement through the use of strain gages and force, pressure, accel- ● Applicable gage resistance
eration and displacement measurement through the use of strain gage 1 or 2-gage system: 120Ω
transducers. The PCD-320A enables the PC to measure voltage signals. 4-gage system: 120 Ω to 1 kΩ
The sensor interfaces are connected to the PC via USB interface. ● Bridge excitation: 2 VAC rms, carrier: 1 kHz sine wave
Connect strain gages and voltage output sensors directly to the rear ● Balance adjustment range
input terminals of sensor interfaces and start the accessory control Resistance: ±2% (±10000 µm/m) or more
software PCD-30A. Then, the PC operates as a measuring instrument. Capacitance: 5000 pF or more
Once sensors are connected, interactive operation on the PC enables ● Balance adjustment method
the operator to obtain measured data in proper engineering units. One Resistance: True electron auto-balance system
sensor interface provides 4 channels and up to 4 units can be connected Capacitance: CST system (automatic tracking)
via USB hub to extend to a 16-channel system suitable for small-scale ● Nonlinearity: Within ±(0.1%FS + 1 digit)
measurement. Needless to say, the PCD-300A can freely be combined ● Gage factor: 2.00 fixed
with the PCD-320A for simultaneous measurement of strain and voltage ● Range: 7 steps of 200, 500, 1000, 2000, 5000, 10000 µm/m and OFF
signals. Thus, the PCD-300 series can effectively be utilized as measur- Accuracy: Within ±(0.5% of range) µm/m
ing tools in every scene including simple experiments and sophisticated ● Frequency band: DC to 200 Hz, deviation ±10%
measurement. ● Mass: Approx. 930 g (excluding accessory AC adapter)
● Model with NDIS connector (PCD-300A M18) and model with
●2 models are available: PCD-300A for strain measurement and PCD- frequency band of DC to 1 kHz (PCD-300A M19) are available.
320A for voltage measurement.
● Connected to the PC via USB interface
● One unit provides 4 channels and 4 units enable 16-channel PCD-320A
● Applicable sensors: Voltage output sensors
measurement.
● Input mode: Unbalanced
● Optional synchronous cable enables simultaneous sampling with 4
● Input resistance: 1 MΩ or more
units.
● Coupling: DC/AC switchable
● Synchronous connection enables simultaneous measurement of strain
● Range: 7 steps of 1, 2, 5, 10, 20, 50 V and OFF
and voltage.
● Frequency response range
● The control software PCD-30A, a standard provision, operates on
Windows 98/98SE/Me/2000/XP. DC coupling: DC to 1 kHz
● The PCD-30A supports both PCD-300A and PCD-320A. AC coupling: 0.2 Hz to 1 kHz
● Low cost Deviation: within +1/–3 dB
● Lowpass filter
● Compact and lightweight
● Optional analysis software DAS-100A enables data analysis on the PC. Transmission characteristics: 2nd order Butterworth
Cutoff frequency: 5 steps of 10, 30, 100, 300 Hz and FLAT
Specifications common to PCD-300A and PCD-320A Amplitude ratio at cutoff point: –(3 ± 1) dB/oct.
● Number of measuring channels: 4 (up to 4 units can be connected Attenuation: –(12 ± 1) dB/oct.
● Measuring input terminals: BNC connectors
together for 16-channel measurement.)
● A-D converter: Resolution12-bit, successive approximation, Input/output not isolated
simultaneous sampling Max. allowable input voltage: 30 VAC or 60 VDC
● Sampling frequency: 1 Hz to 5 kHz Max. rated grounding voltage: 30 VAC or 60 VDC
● Mass: Approx. 750 g (excluding accessory AC adapter)
● External trigger signal: No-voltage conact, open collector, 5 V CMOS
level, number of points: 1
● Interface: USB Software PCD-30A
● Operating temperature/humidity range: 0 to 40 °C, 20 to 85%RH The control software PCD-30A enables the PC to control the sensor
(noncondensing) interfaces PCD-300A/PCD-320A. Using the software, the PC sets
● Power source: 100 to 240 VAC (AC adapter provided standard) measuring conditions and performs data acquisition, graph display and
● Dimensions: 265.2 x 24.7 x 215 mm (excluding protrusions) file conversion to CSV format on MS-Windows 98/98SE/Me/2000/XP.
● Safety standard: EN61010-1, installation category II, pollution degree 2 The software is supplied in CD-R and for use, it is installed in the hard
● EMC standard: EN61326-1, class A instrument disk of the PC.
14
Data Analyzers
Compact Recorder
The EDS-400A is a compact 4-channel recorder equipped with signal ● Typical recording time with 128-MB CF card (standard accessory)
conditioners and high-speed 16-bit resolution A-D converters, enabling
high-speed digital recording of dynamic strain and voltage phenomena. Sampling Number of measuring channels
Desired measuring and recording conditions are set to the recorder by frequency 1 2 3 4
communicating with the PC through LAN or by inserting a compact flash 100 kHz 8.0 minutes
memory card in which the conditions are written beforehand.
Measured data is directly written in the compact flash memory card, 50 kHz 16 minutes 8.0 minutes
while it is possible to monitor the waveform on the PC during data 20 kHz 40 minutes 20 minutes 13 minutes 10 minutes
acquisition in progress. 10 kHz 80 minutes 40 minutes 26 minutes 20 minutes
Acquired data is transferred to the PC either on line via LAN or off line via 5 kHz 160 minutes 80 minutes 53 minutes 40 minutes
the compact flash memory card.
The accessory software enables the PC to display the waveform of the 2 kHz 6.6 hours 3.3 hours 133 minutes 100 minutes
collected data, while the optional DAS-100A data analysis software 1 kHz 13 hours 6.6 hours 4.4 hours 3.3 hours
enables data analysis in various modes. 500 Hz 26 hours 13 hours 8.8 hours 6.6 hours
200 Hz 2.7 days 33 hours 22 hours 16 hours
● Compact and lightweight design requires less space. 100 Hz 5.5 days 2.7 days 44 hours 33 hours
● 4-channel measurement possible with a single unit 50 Hz 11 days 5.5 days 3.7 days 2.7 days
● Up to 8 units can be connected for 32-channel measurement.
● Maximum sampling frequency of 100 kHz (1-channel measurement)
20 Hz 27 days 13 days 9.2 days 6.9 days
ensures high-speed recording. 10 Hz 55 days 27 days 18 days 13 days
● Simultaneous sampling of 4 channels is possible at 20 kHz. 5 Hz 111 days 55 days 37 days 27 days
● Suitable as an onboard data logger 2 Hz 277 days 138 days 92 days 69 days
● LAN interface provided
● Analog filters are built in.
1 Hz 555 days 277 days 185 days 138 days
● Number of measuring channels: 4
● Applicable sensors:
Strain gages (4-gage bridge) Software
Strain gage transducers ● Enables the PC to set, save and read channel, measuring and
Voltage output sensors recording conditions as well as monitor measuring data and perform
● Applicable bridge resistance: 120 to 1000 Ω (4-gage bridge) data collection, data coupling, graph dispay, file conversion and
● Gage factor: 2.00 fixed environmental setting.
● Bridge excitation: 2 VDC ● PC
● Voltage measuring range: ±20 V CPU: Pentium III 700 MHz or higher
● Frequency response range: DC to 20 kHz OS: Windows 2000/XP
● Resolution of A-D conversion: 16 bits Memory: 256 MB or more
● Sampling method: Simultaneous sampling of all channels Hard disk: Blank space 10 MB or more (except for data)
● Samping frequency: 1 Hz to 100 kHz (16 steps)
● LAN interface: 10BASE-T/100BASE-TX
● Monitoring: Waveform, bar graph and numeric data can be monitored
on the PC connected via LAN.
● Data storage: Compact flash memory card (128 MB to 1 GB)
● Synchronized operation: Possible by connecting up to 8 units in
cascade with dedicated synchronous cables.
● Operating temperature/humidity range: 0 to 50 °C, 20 to 90%RH
(noncondensing)
● Vibration resistance: 49.03 m/s2 (5 G) (5 to 55 Hz) (when operating)
● Power source: 10 to 16 VDC
● Dimensions & mass: 100 x 50 x 110 mm (excluding protrusions),
approx. 500 g
15
Data Analyzers
Memory Recorder/Analyzers
16
Data Analyzers
17
Instrumentation Amplifiers & Related Instruments
18
Automotive Test Equipment
● Accurately measures the force and angle of operating steering wheel. Miniature Semiconductor Acceleration Transducer
● Applicable without any remodelling of the vehicle
● Rated capacity ASM-1KBCV/BCH M3
Steering force: 50 to 200 N.m ● Applicable to crash test car bodies
Steering angle: ±1 to 6 turns ● Rated capacity: ±9807 m/s2
● Nonlinearity: Within ±0.5% RO
● Nonlinearity: Within ±1% RO
● Hysteresis: Within ±0.5% RO
● Hysteresis: Within ±1% RO
(Backlash of steering angle: ● Rated output: 1.75 mV/V or more
Within ±0.5% RO) ● Safe overload rating: 150%
● Rated output: 1 to 2 mV/V
● Frequency response range: DC to 2.8 kHz
(for both steering force and angle) ● Mass: 4.0 g ±0.5 g
★ This product falls under export regulations.
19
Automotive Test Equipment
Detector Indicator
20
Civil Engineering/Construction Instruments
21
Civil Engineering/Construction Instruments
Crack Transducer
Temperature Transducer
●For measurement of internal crack of concrete
●Rated capacity: 0 to (5 to 50) mm
●Measuring temperature range: –30 to 70 °C
● For embedded application (hydraulic pressure resistance: 200 kPa) ●Nonlinearity: Within 1.5% RO
● Rated capacity: –30 to 70 °C
●Hysteresis: Within ±1.5% RO
● Resolution: 0.01 °C
●Rated output: 1 mV/V or more
● Measuring error: ±0.3 °C
● Output: 50 µV/V/°C
● Mass: Approx. 120 g
● Formeasurement of an opening degree of joint, such as between Model Diam.* Rated capacity
concrete blocks BED-A 23 200k to 1 MPa
● Crack of rock-bed can be measured. BEF-A 160 200k to 2 MPa
● Rated capacity: 0 to (5 to 50) mm
● Temperature measuring range: –30 to 70 °C
BEB-H 60 50k to 1 MPa
● Nonlinearity: Within ±1.5% RO *Diameter of sensing diaphragm in mm
● Hysteresis: Within ±1.5% RO
● Rated output: 1 mV/V or more
22
Specifications are subject to change without notice for improvement.