0% found this document useful (1 vote)
269 views8 pages

M3g150na07b0 Eng PDF

This document provides information on an EC motor from ebm-papst, model M3G150-NA07-B0. It is a 3-phase motor with a rated voltage of 400 V, rated speed of 580 rpm, power consumption of 1530 W, and rated torque of 2300 Ncm. The motor has IP55 protection, operates in temperature ranges of -40°C to +80°C, and has electronic motor protection and control features.

Uploaded by

karisonpan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
269 views8 pages

M3g150na07b0 Eng PDF

This document provides information on an EC motor from ebm-papst, model M3G150-NA07-B0. It is a 3-phase motor with a rated voltage of 400 V, rated speed of 580 rpm, power consumption of 1530 W, and rated torque of 2300 Ncm. The motor has IP55 protection, operates in temperature ranges of -40°C to +80°C, and has electronic motor protection and control features.

Uploaded by

karisonpan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

M3G150-NA07-B0 EC motor

for barn ventilation

ebm-papst Mulfingen GmbH & Co. KG


Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
[email protected]
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
Amtsgericht (court of registration) Stuttgart · HRA 590344

General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen


Amtsgericht (court of registration) Stuttgart · HRB 590142

Nominal data

Type M3G150-NA07-B0
Motor M3G150-NA

Phase 3~
Nominal voltage VAC 400
Nominal voltage range VAC 380 .. 480
Frequency Hz 50/60

Method of obtaining data ml


Status prelim.
Speed (rpm) min-1 580
Power consumption W 1530
Power output W 1380
Current draw A 2.4
Rated torque Ncm 2300
Min. ambient temperature °C -40
Max. ambient temperature °C 40
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change

Item no. 56852-5-9980 · ENU · Change 204336 · Approved 2019-09-13 · Page 1 / 8

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
M3G150-NA07-B0 EC motor
for barn ventilation

Technical description

Weight 27.9 kg
Motor size 150
Rotor surface Painted black
Electronics housing material Die-cast aluminum, painted gray
Direction of rotation Counterclockwise, viewed toward rotor
Degree of protection IP55
Insulation class "F"
Moisture (F) / Environmental (H) H2+
protection class
Ambient temperature note Occasional start-up at temperatures between -40°C and -25°C is permitted. For
continuous operation at ambient temperatures below -25°C (such as refrigeration
applications), use must be made of a fan design with special low-temperature bearings.
Max. permitted ambient temp. +80 °C
for motor (transport/storage)
Min. permitted ambient temp. for -40 °C
motor (transport/storage)
Installation position Shaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holes On rotor side
Mode S1
Motor bearing Ball bearing; (sealed)
Technical features - Operation and alarm display with LED
- External 15-50 VDC input (parameterization)
- Alarm relay
- Integrated PI controller
- Configurable inputs/outputs (I/O)
- MODBUS V6.0
- Motor current limitation
- RFID - ISO 15693 compatible
- RS-485 MODBUS-RTU
- Soft start
- Voltage output 3.3-24 VDC, Pmax = 800 mW
- Control interface with SELV potential safely disconnected from the mains
- Thermal overload protection for electronics/motor
- Line undervoltage / phase failure detection
Touch current according to IEC <= 3.5 mA
60990 (measuring circuit Fig. 4,
TN system)
Electrical hookup Terminal box
Motor protection Electronic motor protection
Protection class I (with customer connection of protective earth)
Conformity with standards EN 61800-5-1; CE
Approval CSA C22.2 No. 77 + CAN/CSA-E60730-1; EAC; UL 1004-7 + 60730-1

Item no. 56852-5-9980 · ENU · Change 204336 · Approved 2019-09-13 · Page 2 / 8

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
M3G150-NA07-B0 EC motor
for barn ventilation

Product drawing

1 Direction of rotation counterclockwise, viewed toward shaft


2 Max. clearance for screw 20 mm
3 Cable diameter min. 4 mm, max. 10 mm, tightening torque 2±0.3 Nm
4 Tightening torque 1.5 ± 0.2 Nm
Fa Max. permissible axial load: 370 N
Fr Max. permissible radial load: 70 N
Accessory part: Fastening set 38923-1-5191 for impeller installation included in scope of delivery
Impeller 60702-1-3234 accessory part not included in scope of delivery
S Center of gravity

Item no. 56852-5-9980 · ENU · Change 204336 · Approved 2019-09-13 · Page 3 / 8

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
M3G150-NA07-B0 EC motor
for barn ventilation

Connection diagram

No. Conn. Designation Function/assignment


CON1 L1, L2, L3 Power supply, phase, see nameplate for voltage range
PE PE Protective earth
CON2 RSA RS485 interface for MODBUS, RSA; SELV
CON2 RSB RS485 interface for MODBUS, RSB; SELV
CON2 GND Reference ground for control interface, SELV
CON2 IO1 Function parameterizable (see “Optional interface functions” table)
Factory setting:
Digital input - high active, function: Disable input, SELV
- inactive: Pin open or applied voltage < 1.5 VDC
- active: applied voltage 3.5-50 VDC
Reset function: Triggering of error reset on change of state from "enabled" to "disabled"
CON2 IO2 Function parameterizable (see “Optional interface functions” table)
Factory setting:
Analog input 0-10 V / PWM, Ri=100 kΩ, function: Set value
Characteristic curve parameterizable (see input characteristic curve P1-IN), SELV
CON2 IO3 Function parameterizable (see “Optional interface functions” table)
Factory setting:
Analog output 0-10 V, max. 5 mA, function: Fan modulation level
Characteristic curve parameterizable (see output characteristic curve P3-OUT), SELV
CON2 Vout Voltage output 3.3-24 VDC ±5%, Pmax=800 mW, voltage parameterizable
Factory setting: 10 VDC
short-circuit-proof, supply for external devices, SELV
alternatively: 15-50 VDC input for parameterization via MODBUS without line voltage
CON2 COM Status relay, floating status contact, common connection, contact rating 250 VAC / 2 A (AC1) / min. 10
mA, reinforced insulation on supply side and on control interface side
CON2 NC Status relay, floating status contact, break for failure
LED green: status = good, ready for operation
orange: status = warning
red: status = failure
P1-IN Input characteristic curve
P3-OUT Output characteristic curve

Item no. 56852-5-9980 · ENU · Change 204336 · Approved 2019-09-13 · Page 4 / 8

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
○ configurable option

For further information and additional functions see EC Control Software, Fan-Set-App,

D101 [...]
D147 [...]
D104 [...]
D12E [...]
D148 [...]
D16C [...]
D16A [...]
(selected directly
via IO mode)
(selected directly
D130 [0]
D130 [1]
D130 [2]
D130 [5]
D00C [1]
D130 [4]

via IO mode)
or MODBUS Parameter Specification V6.0
INPUT OUTPUT

inverse
M3G150-NA07-B0

configurable IO
functions: normal /
Terminal/plug assignment

MODBUS
Register for IO
mode

source: set value


source: sensor value
switch: parameter set: #1 / #2
switch: control function: heating (pos.) /
switch: direction of rotation: cw / ccw

cooling (neg.)
signal: actual speed
signal: system modulation level %
signal: remote control output 0-10V
pulse input for auto-adressing
pulse output for auto-adressing

switch: set value source


switch: fan enable / disable
signal: tach out
signal: diagnostics out
signal: fan modulation level %
CON2 configurable IO mode electrical specification configuration
Din1 (active high): digital input not active: pin open or applied voltage < 1,5VDC D158 [0]
○ ○ ○ ○ ○ ○
active: applied voltage 3,5-50VDC, SELV
IO1 ○ Ain1 0-10V/PWM: analog input Ri=100K, characteristic curve parameterizable, fPWM=1k..10KHz, SELV D158 [2] ○ ○
○ Tach out (open collector output) Umax=50VDC, Imax=20mA, SELV D158 [5] ○
○ Diagnostics out (open collector output) Umax=50VDC, Imax=20mA, SELV D158 [6] ○
○ Din2 (active high): digital input not active: pin open or applied voltage < 1,5VDC D159 [0]
○ ○ ○ ○ ○
active: applied voltage 3,5-50VDC, SELV
IO2
Ain2 0-10V/PWM: analog input Ri=100K, characteristic curve parameterizable, fPWM=1k..10KHz, SELV D159 [2]
○ ○

Item no. 56852-5-9980 · ENU · Change 204336 · Approved 2019-09-13 · Page 5 / 8


○ Ain2 4-20mA: analog input Ri=125R, characteristic curve parameterizable, SELV D159 [3]
○ Din3 (active high): digital input not active: pin open or applied voltage < 1,5VDC D15A [0]
EC motor
for barn ventilation

active: applied voltage 3,5-50VDC, SELV


○ Din3 (active low): digital input
○ ○ ○ ○ ○
active: pin open or applied voltage 3,5-50VDC D15A [1]
not active: applied voltage < 1,5VDC, SELV
○ PWMin3: digital input 40Hz - 10kHz, characteristics parameterizable D15A [7]
IO3
not active: pin open or applied voltage 3,5-50VDC ○
active: applied voltage < 1,5VDC, SELV
Aout3 0-10V: analog output function parameterizable, max. 5mA, max output frequency 300Hz, SELV D15A [4] ○ ○ ○ ○ ○
○ Tacho out (pulses), analog output 0-10V max. 5mA, max output frequency 300Hz, SELV D15A [5] ○
○ Diagnostics out (pulses) 0-10V max. 5mA, max output frequency 300Hz, SELV D15A [6] ○
RSA RS485 bus connection, MODBUS RTU, specification V6.0, SELV
○ ○ ○ ○ ○ ○
RSB
voltage output voltage parameterizable 3,3...24VDC +/- 5,5%, Pmax=800mW, short-circuit-proof, D16E [...]
Vout
supply for external devices, SELV
alternatively: Input auxillary power supply for 15...50VDC
parameter-ization via RS485/MODBUS RTU without line
voltage

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
M3G150-NA07-B0 EC motor
for barn ventilation

Curves: Air performance without diffuser


in. wg
Pa

50 4
0.2

ρ = 1.15 kg/m³ ± 2 %
Measurement: LU-195180-1

Air performance measured according to ISO


40
5801 installation category A. For detailed
0.15

8 information on the measurement setup,


contact ebm-papst. Intake sound level:
3 Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
30 valid under the specified measuring
conditions and may vary due to conditions
7 of installation. For deviations from the
0.1

standard configuration, the parameters


12 have to be checked on the installed unit.

20 2
The measurement was carried out with the
11
6 ebm-papst impeller 60702-1-3234
16
0.05

10 10
15

14

13 920000 525000 1 cfm


pfs

0 5000 10000 15000

qv 10000 20000 30000 40000 m³/h

Measured values
Wired U f n Ped I LpAin LwAin LwAout qV pfs qV pfs
V Hz min-1 W A dB(A) dB(A) dB(A) m3/h Pa cfm in. wg
1 3~ 230 50 580 1310 3.66 71 79 80 46970 0 27645 0.00
2 3~ 230 50 580 1415 3.94 71 79 80 43585 20 25655 0.08
3 3~ 230 50 580 1477 4.10 71 79 80 40755 35 23990 0.14
4 3~ 230 50 580 1530 4.25 71 79 80 37480 50 22060 0.20
5 3~ 230 50 500 840 2.34 67 76 77 40490 0 23830 0.00
6 3~ 230 50 500 906 2.52 67 75 76 37570 16 22115 0.06
7 3~ 230 50 500 946 2.62 67 75 76 35135 26 20680 0.10
8 3~ 230 50 500 982 2.71 67 76 76 32310 37 19015 0.15
9 3~ 230 50 400 430 1.20 62 70 71 32395 0 19065 0.00
10 3~ 230 50 400 464 1.29 62 70 71 30060 10 17690 0.04
11 3~ 230 50 400 484 1.34 62 70 70 28110 17 16545 0.07
12 3~ 230 50 400 503 1.39 62 70 70 25850 24 15215 0.10
13 3~ 230 50 300 181 0.51 54 63 64 24295 0 14300 0.00
14 3~ 230 50 300 196 0.54 54 63 63 22545 6 13270 0.02
15 3~ 230 50 300 204 0.57 54 63 63 21080 9 12410 0.04
16 3~ 230 50 300 212 0.59 54 63 63 19385 13 11410 0.05
Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Ped = Power consumption · I = Current draw · LpAin = Sound pressure level intake side · LwAin = Sound power level intake side
LwAout = Sound power level outlet side · qV = Air flow · pfs = Pressure increase

Item no. 56852-5-9980 · ENU · Change 204336 · Approved 2019-09-13 · Page 6 / 8

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
M3G150-NA07-B0 EC motor
for barn ventilation

Curves: Air performance with diffuser


in. wg
Pa

70 4

ρ = 1.15 kg/m³ ± 2 %
0.25

60
Measurement: LU-195181-1

Air performance measured according to ISO


8 5801 installation category A. For detailed
50 3 information on the measurement setup,
0.2

contact ebm-papst. Intake sound level:


Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
40 valid under the specified measuring
0.15

7 conditions and may vary due to conditions of


installation. For deviations from the standard
12 configuration, the parameters have to be
checked on the installed unit.
30

2 The measurement was carried out with the


0.1

11
20 ebm-papst impeller 60702-1-3234
16 6
15
0.05

10
10
14

13 9 5 1
pfs

0 5000 10000 15000 20000 25000 30000 cfm

qv 10000 20000 30000 40000 50000 m³/h

Measured values
Wired U f n Ped I LpAin LwAin LwAout qV pfs qV pfs
V Hz min-1 W A dB(A) dB(A) dB(A) m3/h Pa cfm in. wg
1 3~ 230 50 580 914 2.69 73 81 84 54895 0 32310 0.00
2 3~ 230 50 580 1173 3.33 71 79 83 49005 25 28840 0.10
3 3~ 230 50 580 1379 3.85 71 79 82 42920 50 25260 0.20
4 3~ 230 50 580 1530 4.25 71 79 82 37590 70 22125 0.28
5 3~ 230 50 500 586 1.72 69 77 81 47320 0 27855 0.00
6 3~ 230 50 500 751 2.13 67 76 79 42245 18 24865 0.07
7 3~ 230 50 500 884 2.47 67 75 78 37000 37 21780 0.15
8 3~ 230 50 500 965 2.67 67 75 78 32405 52 19075 0.21
9 3~ 230 50 400 300 0.88 64 71 75 37860 0 22280 0.00
10 3~ 230 50 400 385 1.09 62 70 73 33795 12 19890 0.05
11 3~ 230 50 400 452 1.26 61 69 73 29600 24 17420 0.10
12 3~ 230 50 400 494 1.37 61 70 73 25925 33 15260 0.13
13 3~ 230 50 300 127 0.37 56 64 68 28395 0 16710 0.00
14 3~ 230 50 300 162 0.46 55 63 66 25345 7 14920 0.03
15 3~ 230 50 300 191 0.53 54 62 65 22200 13 13065 0.05
16 3~ 230 50 300 208 0.58 54 62 66 19445 19 11445 0.08
Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Ped = Power consumption · I = Current draw · LpAin = Sound pressure level intake side · LwAin = Sound power level intake side
LwAout = Sound power level outlet side · qV = Air flow · pfs = Pressure increase

Item no. 56852-5-9980 · ENU · Change 204336 · Approved 2019-09-13 · Page 7 / 8

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
M3G150-NA07-B0 EC motor
for barn ventilation

Curves: Speed (rpm)

2.600 1.300
6,4
6,2 2.500 1.250

6 2.400 1.200
5,8 2.300 1.150
5,6
2.200 1.100
5,4
5,2 2.100 1.050

5 2.000 1.000
4,8
1.900 950
4,6
1.800 900
4,4
4,2 1.700 850

4 1.600 800
3,8 1.500 750
3,6
1.400 700
3,4
n [1/min]
P1 [W]
I1 [A]

1.300 650
3,2
3 1.200 600
2,8 1.100 550
2,6
1.000 500
2,4
2,2 900 450

2 800 400
1,8 700 350
1,6
600 300
1,4
1,2 500 250

1 400 200
0,8
300 150
0,6
200 100
0,4
0,2 100 50

0 0
0 200 400 600 800 1.000 1.200 1.400 1.600 1.800 2.000 2.200 2.400 2.600 2.800 3.000 3.200
Md [Ncm]

Item no. 56852-5-9980 · ENU · Change 204336 · Approved 2019-09-13 · Page 8 / 8

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

You might also like