ABP SERIES 32305128

Issue G

Basic Board Mount Pressure Sensors


High Accuracy, Compensated/Amplified
60 mbar to 10 bar | 6 kPa to 1 MPa | 1 psi to 150 psi
Digital or Analog Output, Liquid Media Capable
DESCRIPTION to aging of the sensor terminals, which
The ABP Series are piezoresistive silicon minimizes the concern about aging
pressure sensors offering a ratiometric of the terminals prior PCB assembly.
analog or digital output for reading Pressure choices allow engineers
pressure over the specified full scale to select range required for their
pressure span and temperature range. application. Leadless SMT, SMT, and
They are calibrated and temperature DIP package options.
compensated for sensor offset, • Cost-effective: Small size helps
sensitivity, temperature effects and engineers reduce design and
accuracy errors (which include non- manufacturing costs while maintaining
linearity, repeatability and hysteresis) enhanced performance and reliability
using an on-board Application Specific of the systems they design.
Integrated Circuit (ASIC). Calibrated • Accurate: Total Error Band (TEB) and
output values for pressure are updated wide pressure range enable engineers FEATURES
at approximately 1 kHz for analog and to optimize system performance by • Measures gage and differential
2 kHz for digital. All products are improving resolution and system pressures
designed and manufactured according accuracy. Optional internal diagnostics • Total Error Band (see Figure 1): ±1.5 %FSS
to ISO 9001 standards. validate that the sensor readings are • Liquid media option: Allows for wet/wet
• Dry gases option: The input port is correct. operation on dual ported devices
limited to non-corrosive, non-ionic • Flexible: Supply voltage range, variety • Industry-leading long-term stability:
media (e.g., dry air, gases) and should of pressure units, types, and ranges, ±0.25 %FSS
not be exposed to condensation. The output options, and wide operating • Industry-leading accuracy: ±0.25 %FSS BFSL
gases are limited to media compatible temperature range simplify use in the • Wide pressure range: 60 mbar to 10 bar
with high temperature polyamide, application. | 6 kPa to 1 MPa | 1 psi to 150 psi
silicone, alumina ceramic, silicon, gold, • Versatile: Wet-media compatibility, • As small as 8 mm x 7 mm
and glass. sleep mode, and temperature • High burst pressures (see Table 7)
• Liquid media option: Includes an output options make the sensor a • Calibrated over temperature range of
additional silicone-based gel coating versatile choice for Internet of Things 0°C to 50°C [32°F to 122°F]
to protect the electronics under applications. • Operates from a single power supply of
port P1, which enables use with • Honeywell Brand: Utilize proprietary either 3.3 Vdc or 5.0 Vdc
non-corrosive liquids (e.g. water and Honeywell technology, and are • Output: Ratiometric analog or I2C- or
saline) and in applications where protected by multiple global patents. SPI-compatible 12-bit digital
condensation can occur. Since port P2 • Food Safety Certification for North • Power consumption: 2 µA typical when
is designed for use with non-corrosive America, Europe and Asia. utilizing sleep mode option
liquids, this option is often suitable for • Meets IPC/JEDEC J-STD-020D.1
wet-wet differential sensing. POTENTIAL APPLICATIONS Moisture Sensitivity Level 1 requirements
• Medical: CPAP, blood analysis, blood • REACH and RoHS compliant
pressure monitoring, breast pumps, • Options: Internal diagnostic function,
DIFFERENTIATION liquid media, sleep mode, temperature
• Enhanced accuracy helps the design drug dosing, hospital beds, massage
machines, oxygen concentrators, output
engineer fully understand the error in • Sensor materials have been tested and
measurement. patient monitoring, sleep apnea
equipment, urine analyzers, certified for these food safety standards:
• Wide supply voltage range offers - NSF-169
design flexibility. ventilators/portable ventilators, and
wound therapy - BPA Free
• Power consumption when utilizing - LFGB
sleep mode option allows for use in • Industrial: Air brakes, HVAC/
battery-powered applications. transmitters, life sciences, material
handling, pneumatic control and
regulation, process gas monitoring, PORTFOLIO
VALUE TO CUSTOMERS and valve positioning/positioners
• Simplifies design-in: Small size • Commercial: Air beds, coffee makers, Honeywell offers a variety
saves room on the PC board (PCB), and washing machines of board mount pressure sensors for
or simplifies design in smaller and
lower power devices. Meets Moisture potential use in medical and industrial
Sensitivity Level 1 requirements, which applications. To view the entire product
allows for unlimited shelf life when
stored at <30 ºC/85 %RH and, under portfolio, click here.
most storage conditions, allows for
PCB soldering without any material
concern about solder joint quality due

Sensing and Internet of Things


BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES
FIGURE 1. TOTAL ERROR BAND
Total Error Band (TEB) is a single specification that includes
all possible sources of error. TEB should not be confused with All Possible Errors
accuracy, which is actually a component of TEB. TEB is the worst Offset
error that the sensor could experience. The TEB specification Full Scale Span
on a datasheet may be confusing. Honeywell uses the TEB Pressure Non-Linearity
specification in its datasheet because it is the most comprehensive Accuracy Total
Pressure Hysteresis Error
measurement of a sensor’s true accuracy. Honeywell also BFSL
Pressure Non-Repeatibility Band
provides the accuracy specification in order to provide a common
comparison with competitors’ literature that does not use the Thermal Effect on Offset
TEB specification. Many competitors do not use TEB—they simply Thermal Effect on Span
specify the accuracy of their device. Their accuracy specification, Thermal Hysteresis
however, may exclude certain parameters. On their datasheet, the
errors are listed individually. When combined, the total error (or
what would be TEB) can be significant.
TABLE 1. ABSOLUTE MAXIMUM RATINGS1
CHARACTERISTIC MIN. MAX. UNIT
Supply voltage (Vsupply) -0.3 6.0 Vdc
Voltage on any pin -0.3 Vsupply + 0.3 V
Digital interface clock frequency:
I2C 100 400 kHz
SPI 50 800
ESD susceptibility (human body model) 2 — kV
Storage temperature -40 [-40] 85 [185] °C [°F]
Soldering time and temperature:
lead solder temperature (DIP) 4 s max. at 250°C [482°F]
peak reflow temperature (Leadless SMT, SMT) 15 s max. at 250°C [482°F]
1
Absolute maximum ratings are the extreme limits the device will withstand without damage.
TABLE 2. ENVIRONMENTAL SPECIFICATIONS
CHARACTERISTIC PARAMETER
Humidity:
all external surfaces 0 %RH to 95 %RH, non-condensing
internal surfaces of Liquid Media Option (T, V, B, C, F, G) 0 %RH to 100 %RH, condensing
internal surfaces of Dry Gases Option (N, D) 0 %RH to 95 %RH, non-condensing
Vibration 15 g, 10 Hz to 2 kHz
Shock 100 g, 6 ms duration
Life1 1 million pressure cycles minimum
J-STD-020-D.1 Moisture Sensitivity Level 1
Solder reflow
(unlimited shelf life when stored at <30°C/85 %RH)
Certification (silicone gel coating option: Port 1 only) NSF-169, BPA Free, LFGB
1
Life may vary depending on specific application in which the sensor is used.

TABLE 3. WETTED MATERIALS1


PRESSURE PORT 1 (P1)
COMPONENT PRESSURE PORT 2 (P2)
DRY GAS OPTION LIQUID MEDIA OPTION
Ports and covers high temperature polyamide
Metal gel ring — 304 SST —
Substrate alumina ceramic — alumina ceramic
Adhesives epoxy, silicone epoxy, silicone gel epoxy, silicone
silicon, glass, gold,
Electronic components — silicon
aluminum
1
Contact Honeywell Customer Service for detailed material information.
TABLE 4. SENSOR PRESSURE TYPES
PRESSURE TYPE DESCRIPTION
Gage Output is proportional to the difference between applied pressure and atmospheric (ambient) pressure.
Differential Output is proportional to the difference between the pressures applied to each port (Port 1 – Port 2).
2 Sensing and Internet of Things
BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES

TABLE 5. OPERATING SPECIFICATIONS


ANALOG DIGITAL
CHARACTERISTIC UNIT
MIN. TYP. MAX. MIN. TYP. MAX.
Supply voltage (Vsupply):1, 2, 3
3.3 Vdc 3.0 3.3 3.6 3.0 3.3 3.6 Vdc
5.0 Vdc 4.75 5.0 5.25 4.75 5.0 5.25
Supply current:
3.3 Vdc — 2.1 2.8 — 3.1 3.9 mA
5.0 Vdc — 2.7 3.8 — 3.7 4.6 mA
sleep mode option — — — — 1 10 µA
Operating temperature range 4 -40 [-40] — 85 [185] -40 [-40] — 85 [185] °C [°F]
Compensated temperature range5 0 [-32] — 50 [122] 0 [-32] — 50 [122] °C [°F]
Temperature output option 6
— — — — ±4 — °C
Startup time (power up to data ready) — — 5 — — 3 ms
Response time — 1 — — 0.46 — ms
Clipping limit:
upper — — 97.5 — — — %Vsupply
lower 2.5 — — — — —
I2C/SPI voltage level:
low — — — — — 20 %Vsupply
high — — — 80 — —
Pull up on SDA/MISO, SCL/SCLK, SS — — — 1 — — kOhm
Total Error Band 7
— — ±1.5 — — ±1.5 %FSS8
Accuracy 9
— — ±0.25 — — ±0.25 %FSS BFSL
Long term stability (1000 hr, 25°C [77°F]) — — ±0.25 — — ±0.25 %FSS
0.03 — — — — — %FSS
Output resolution
— — — 12 — — bits
1
Sensors are either 3.3 Vdc or 5.0 Vdc based on the catalog listing selected.
2
Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified
operating voltage.
3
The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause
electrical failure.
4
Operating temperature range: The temperature range over which the sensor will produce an output proportional to pressure.
5
Compensated temperature range: The temperature range over which the sensor will produce an output proportional to
pressure within the specified performance limits.
6
Temperature output option: Typical temperature output error over the compensated temperature range of 0°C to 50°C.
Operation in Sleep Mode may affect temperature output error depending on duty cycle.
7
Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and
pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability,
thermal effect on offset, thermal effect on span, and thermal hysteresis.
8
Full Scale Span (FSS): The algebraic difference between the output signal measured at the maximum (Pmax.) and minimum
(Pmin.) limits of the pressure range. (See Figure 2.)
9
Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the
pressure range at 25°C [77°F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.

TABLE 6. SENSOR OUTPUT AT SIGNIFICANT PERCENTAGES (DIGITAL VERSIONS ONLY)


DIGITAL COUNTS
% OUTPUT
DECIMAL HEX
0 0 0x0000
10 1638 0x0666
50 8192 0x2000
90 14746 0x399A
100 16383 0x3FFF

Sensing and Internet of Things 3


BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES

FIGURE 2. TRANSFER FUNCTION LIMITS1


Analog Versions

Compensated Pressure Range


100
90
Output (%Vsupply)
80
70
60 Ideal
50
1.5% Total Error Band
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10
Pmin. Pmax.
Pressure (example unit)
0.8 x Vsupply
Output (V) = x (Pressureapplied – Pmin.) + 0.10 x Vsupply
Pmax. – Pmin.

Digital Versions

Compensated Pressure Range


100
Output (% of 214 counts)

90
80
70
60 Ideal
50
1.5% Total Error Band
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10
Pmin. Pmax.
Pressure (example unit)
80%
Output (% of 214 counts) = x (Pressureapplied – Pmin.) + 10%
Pmax. – Pmin.

1
Transfer Function “A” is shown. See Figure 3 for other available transfer functions.

4 Sensing and Internet of Things


BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES

FIGURE 3. NOMENCLATURE AND ORDER GUIDE

For example, ABPDNNN150PGAA3 defines an ABP Series Amplified Basic Pressure Sensor, DIP package, NN pressure port,
dry gases only, no diagnostics, 150 psi gage pressure range, analog output type, 10% to 90% of Vsupply (analog), transfer
function, no temperature output, no sleep mode, 3.3 Vdc supply voltage.

ABP D NN N 150PG A A 3
Product Series Supply Voltage
3 3.3 Vdc
ABP Amplified Basic
5 5.0 Vdc
Transfer Function3
Package
D DIP (Dual Inline Pin) 10% to 90% of Vsupply (analog), 214 counts (digital)
A no temperature output, no sleep mode
M SMT (Surface Mount Technology)
10% to 90% of 214 counts (digital only)
L Leadless SMT D temperature output enabled, sleep mode enabled
10% to 90% of 214 counts (digital only)
Pressure Port S no temperature output, sleep mode enabled
DIP SMT Leadless SMT
10% to 90% of 214 counts (digital only)
NN No port NN No port NN No port T temperature output enabled, no sleep mode

Output Type
A Analog 3 I2C, Address 0x38
S SPI 4 I2C, Address 0x48
Single axial Single axial Single axial 0 I2C, Address 0x08 5 I2C, Address 0x58
AN barbed port AN barbed port AN barbed port
1 I2C, Address 0x18 6 I2C, Address 0x68
2 I2C, Address 0x28 7 I2C, Address 0x78

Pressure Range1, 2
60 mbar to 10 bar 6 kPa to 1 MPa 1 psi to 150 psi
Differential Differential Differential

Single axial Single axial Single axial 060MD ±60 mbar 006KD ±6 kPa 001PD ±1 psi
LN barbless port LN barbless port LN barbless port 100MD ±100 mbar 010KD ±10 kPa 005PD ±5 psi
160MD ±160 mbar 016KD ±16 kPa 015PD ±15 psi
250MD ±250 mbar 025KD ±25 kPa 030PD ±30 psi
400MD ±400 mbar 040KD ±40 kPa 060PD ±60 psi
600MD ±600 mbar 060KD ±60 kPa
001BD ±1 bar 100KD ±100 kPa
Single radial Single radial 1.6BD ±1.6 bar 160KD ±160 kPa
JN barbless port JN barbless port 2.5BD ±2.5 bar 250KD ±250 kPa
004BD ±4 bar 400KD ±400 kPa
Gage Gage Gage
060MG 0 mbar to 60 mbar 006KG 0 kPa to 6 kPa 001PG 0 psi to 1 psi
100MG 0 mbar to 100 mbar 010KG 0 kPa to 10 kPa 005PG 0 psi to 5 psi
160MG 0 mbar to 160 mbar 016KG 0 kPa to 16 kPa 015PG 0 psi to 15 psi
Dual radial Dual radial
JJ barbless ports, JJ barbless ports, 250MG 0 mbar to 250 mbar 025KG 0 kPa to 25 kPa 030PG 0 psi to 30 psi
same side same side 400MG 0 bar to 400 mbar 040KG 0 kPa to 40 kPa 060PG 0 psi to 60 psi
600MG 0 bar to 600 mbar 060KG 0 kPa to 60 kPa 100PG 0 psi to 100 psi
001BG 0 bar to 1 bar 100KG 0 kPa to 100 kPa 150PG 0 psi to 150 psi
1.6BG 0 bar to 1.6 bar 160KG 0 kPa to 160 kPa
2.5BG 0 bar to 2.5 bar 250KG 0 kPa to 250 kPa
004BG 0 bar to 4 bar 400KG 0 kPa to 400 kPa
Single radial Single radial
RN barbed port RN barbed port 006BG 0 bar to 6 bar 600KG 0 kPa to 600 kPa
010BG 0 bar to 10 bar 001GG 0 kPa to 1 MPa

Option
N Dry gases only, no diagnostics
D Dry gases only, diagnostics on

RR Dual radial
RR Dual radial T Liquid media, no diagnostics
barbed ports, barbed ports,
same side same side V Liquid media, diagnostics on
B Liquid media, food grade gel, no diagnostics4
C Liquid media, food grade gel, diagnostics on4
F Liquid media, fluorosilicone gel, no diagnostics4
G Liquid media, fluorosilicone gel, diagnostics on4

1
Custom pressure ranges are available. Contact Honeywell Customer Service for more information.
2
See the explanation of sensor pressure types in Table 4.
3
The Transfer Function limits define the output of the sensor at a given pressure input. By specifying Pmin. and Pmax., the output at Pmin. and Pmax., the complete transfer function of the sensor
is defined. See the graphical representations of the transfer function in Figure 3.
4
Custom gel options are available. Contact Honeywell Customer Service for more information.

Sensing and Internet of Things 5


BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES

TABLE 7. PRESSURE RANGE SPECIFICATIONS


PRESSURE PRESSURE RANGE OVERPRESSURE1 BURST PRESSURE2 COMMON
RANGE UNIT MODE
(SEE FIGURE 3.) PMIN. PMAX. PORT 1 (P1) PORT 2 (P2) PORT 1 (P1) PORT 2 (P2) PRESSURE3
1 psi to 150 psi
Differential
060MD -60 60 mbar 2000 850 3500 1000 10000
100MD -100 100 mbar 4000 1400 7000 2500 10000
160MD -160 160 mbar 4000 1400 7000 2500 10000
250MD -250 250 mbar 10000 2000 19000 4000 10000
400MD -400 400 mbar 10000 2000 19000 4000 10000
600MD -600 600 mbar 17000 2000 19000 4000 10000
001BD -1 1 bar 17 4 19 8 17
1.6BD -1.6 1.6 bar 17 8 19 16 17
2.5BD -2.5 2.5 bar 17 8 19 16 17
004BD -4.0 4.0 bar 17 16 19 19 17
Gage
060MG 0 60 mbar 2000 — 3500 — 5500
100MG 0 100 mbar 2000 — 3500 — 10000
160MG 0 160 mbar 2000 — 3500 — 10000
250MG 0 250 mbar 4000 — 7000 — 10000
400MG 0 400 mbar 10000 — 19000 — 10000
600MG 0 600 mbar 10000 — 19000 — 10000
001BG 0 1 bar 17 — 19 — 17
1.6BG 0 1.6 bar 17 — 19 — 17
2.5BG 0 2.5 bar 17 — 19 — 17
004BG 0 4 bar 17 — 19 — 17
006BG 0 6 bar 17 — 19 — 17
010BG 0 10 bar 17 — 19 — 17
6 kPa to 1 MPa
Differential
006KD -6 6 kPa 200 85 350 100 1000
010KD -10 10 kPa 400 140 700 250 1000
016KD -16 16 kPa 400 140 700 250 1000
025KD -25 25 kPa 1000 200 1900 400 1000
040KD -40 40 kPa 1000 200 1900 400 1000
060KD -60 60 kPa 1700 200 1900 400 1000
100KD -100 100 kPa 1700 400 1900 800 1700
160KD -160 160 kPa 1700 800 1900 1600 1700
250KD -250 250 kPa 1700 800 1900 1600 1700
400KD -400 400 kPa 1700 1600 1900 1900 1700
Gage
006KG 0 6 kPa 200 — 350 — 550
010KG 0 10 kPa 200 — 350 — 1000
016KG 0 16 kPa 200 — 350 — 1000
025KG 0 25 kPa 400 — 700 — 1000
040KG 0 40 kPa 1000 — 1900 — 1000
060KG 0 60 kPa 1000 — 1900 — 1000
100KG 0 100 kPa 1700 — 1900 — 1700
160KG 0 160 kPa 1700 — 1900 — 1700
250KG 0 250 kPa 1700 — 1900 — 1700
400KG 0 400 kPa 1700 — 1900 — 1700
600KG 0 600 kPa 1700 — 1900 — 1700
001GG 0 1 MPa 1.7 — 1.9 — 1.7

6 Sensing and Internet of Things


BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES

TABLE 7. PRESSURE RANGE SPECIFICATIONS (CONTINUED)


PRESSURE PRESSURE RANGE OVERPRESSURE1 BURST PRESSURE2 COMMON
RANGE UNIT MODE
(SEE FIGURE 3.) PMIN. PMAX. Port 1 (P1) Port 2 (P2) Port 1 (P1) Port 2 (P2) PRESSURE3
1 psi to 150 psi
Differential
001PD -1 1 psi 30 10 50 15 150
005PD -5 5 psi 150 30 275 40 150
015PD -15 15 psi 250 60 275 120 250
030PD -30 30 psi 250 120 275 240 250
060PD -60 60 psi 250 250 275 275 250
Gage
001PG 0 1 psi 30 — 50 — 150
005PG 0 5 psi 150 — 275 — 150
015PG 0 15 psi 250 — 275 — 250
030PG 0 30 psi 250 — 275 — 250
060PG 0 60 psi 250 — 275 — 250
100PG 0 100 psi 250 — 275 — 250
150PG 0 150 psi 250 — 275 — 250
Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the
1

operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified this applies to all
available pressure ports at any temperature with the operating temperature range.
2
Burst pressure: The maximum pressure that may be applied to the specified port (P1 or P2) of the product without causing escape of pressure
media. Product should not be expected to function after exposure to any pressure beyond the burst pressure.
3
Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing
changes in specified performance.

FIGURE 4. RECOMMENDED FILTER CAP

VSUPPLY

VSUPPLY

0.1 F
VOUT*

0.001 F*
Ground

*Analog output version only.

Sensing and Internet of Things 7


BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES
FIGURE 5. DIP PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].)
DIP NN: No port

8,0
[0.32]
7,3
[0.29] 2,54 Typ.
4,0 [0.100]
[0.16] 2X 1,45
3,23 Wet media
[0.127] 6 5 4 [0.057]
4 5 6
2,95 Dry media
[0.116]
5,5
[0.22]

6,3
[0.25] 11,5 11,0
[0.45] [0.43]

3 2 1 1,0
[0.04] 1 2 3
0,25 Typ.
8,6 [0.010]
[0.34]

3,81
[0.150]

6X 0,46
[0.018]

DIP AN: Single axial barbed port


8,0
[0.32]
7,3
[0.29] 7,00 3,63 Wet media 2,54 Typ. 2X 1,45
4,0 [0.276] [0.143] [0.100] [0.057]
[0.16]
3,35 Dry media
4 5 6 [0.131] 6 5 4
3,56
[0.140]
ø1,91
5,5 [0.075]
[0.22]

6,3 ø2,74 11,5


11,0
[0.25] [0.108] [0.45]
[0.43]

ø2,32
[0.091]

3 2 1 1,0
[0.04] 1 2 3
8,6 0,25 Typ.
[0.34] [0.010]

3,81
[0.150]

6X 0,46
[0.018]

8 Sensing and Internet of Things


BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES
FIGURE 5. DIP PACKAGE DIMENSIONAL DRAWINGS (CONTINUED)
DIP LN: Single axial
barbless port

8,0
7,3 [0.32]
[0.29]
2,54 Typ.
4,0 4,80 3,23 Wet media [0.100]
[0.16] [0.189] [0.127] 2X 1,45
[0.057]
2,95 Dry media 6 5 4
4 5 6 [0.116]

5,5
[0.22]

6,3 ø5,00 2,68 11,5 11,0


[0.25] [0.197] [0.106] [0.45] [0.43]

1,0
3 2 1 [0.04] 8,6 0,25 Typ. 1 2 3
[0.34] [0.010]
6X 0,46
[0.018]

3,81
[0.150]

6X 0,46
[0.018]

DIP JN: Single radial


barbless port

0,7 3,38 Wet media


[0.03 [0.133]
8,0 4,65 2.16
3,10 Dry media [0.32] [0.183] [0.085]
4 5 6 [0.122] 6 5 4

4,45
[0.175]

6,3 11,5
[0.45] 11,0
[0.25]
ø1,88 [0.43]
[0.074] 0,25 Typ.
[0.010]

1,0
3 2 1 [0.04] 1 2 3
7,3 8,6
[0.29] [0.34] 2X 1,45 2,54 Typ.
[0.057] [0.100]

3,81
[0.150]

6X 0,46
[0.018]

Sensing and Internet of Things 9


BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES

FIGURE 5. DIP PACKAGE DIMENSIONAL DRAWINGS (CONTINUED)


DIP JJ: Dual radial 0,7
[0.03
3,38 Wet media
[0.133]
8,0
[0.32]
barbless ports, same side 2X 4,0 3,10 Dry media 2,54 Typ.
[0.100] 2X 1,47
[0.16] [0.122] [0.058]
4 5 6 2,82
[0.111] 6 5 4
2X 4,65
[0.183]
Port 1 4,45
[0.175] 2X ø1,88
[0.074]

2,10 6,3
[0.083] [0.25] Port 1 11,5 11,0
[0.45] [0.43]
Port 2 4,45
Port 2 [0.175]

3 2 1 1,0 5,06 Wet media


[0.04] 0,25 Typ. 1 2 3 [0.199]
7,3 8,6 [0.010]
[0.29] [0.34] 4,78 Dry media
[0.188]

3,81
[0.150]

6X 0,46
[0.018]

DIP RN: Single radial


barbed port 8,0
[0.32]
2,01
4,0 0,5 3,58 Wet media [0.079]
[0.16] [0.02] [0.141] 2,54 Typ. 2X 1,47
[0.100] [0.058]
4 5 6 3,30 Dry media 6 5 4
ø1,60 [0.129]
[0.063]
3,10
[0.122] 4,55
[0.179]

6,3 11,0
11,5 [0.43]
[0.25] [0.45]
ø1,75
[0.069]
ø2,10
[0.083] 0,25 Typ.
[0.010]
1,65
3 2 1 1 2 3 [0.065]
7,3 8,6
[0.34] 4,75
[0.29] [0.187]

3,81
[0.150]

6X 0,46
[0.018]

DIP RR: Dual radial 8,0


barbed ports, same side [0.32]
2,54 Typ.
3,58 Wet media 2,78 [0.100]
2X 4,0 [0.141] [0.109]
[0.16] 2X 1.45
3,30 Dry media [0.057] 6 5 4 2X 4,75
4 5 6
[0.129] [0.187]

0,5 2X ø1,75
[0.02] 4,55 [0.069]
Port 1 [0.179] 2X ø1,60
[0.063]

1,90 6,3
[0.075] [0.25] Port 1 Port 2 11,5 11,0
[0.45] [0.43]
2X ø2,10
4,55 [0.083]
Port 2
[0.179]

1.0
[0.04] 4,76
3 2 1 8,6 1 2 3 [0.187]
0,25 Typ.
7,3 [0.34] [0.010]
[0.29]

3,81
[0.150]

6X 0,46
[0.018]

10 Sensing and Internet of Things


BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES

FIGURE 6. SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].)


SMT NN: No port 7,3
[0.29]
8.0
4,0 [0.32]
[0.16] 3,23 Wet media 0,25 Typ.
4 5 6 [0.127] [0.010] 6 5 4
2,95 Dry media
[0.116]
5,5
[0.22]

6,3 11,0
[0.25] 11,5
[0.45] [0.43]

6X 1,28
[0.050]

3 2 1 1,0
[0.04] 1 2 3
4,2 6X 0,46
[0.17] [0.018] 2X 1,45
2,54 Typ.
[0.100] [0.057]

SMT AN: Single axial 7,3 7,00 3,63 Wet media


barbed port 4,0
[0.29] [0.276] [0.143] 8.0
[0.16] 3,35 Dry media [0.32]
4 5 6 [0.131] 6 5 4
0,25 Typ.
[0.010]
3,56
[0.140]
5,5
[0.22]

6,3
[0.25] 11,5 11,0
[0.45] [0.43]
ø2,74
[0.108] 6X 1,28
ø2,32 [0.050]
ø1,91 [0.091]
[0.075]
1,0
3 2 1 [0.04] 4,2 1 2 3
[0.17] 6X 0,46
[0.018]
2,54 Typ. 2X 1,45
[0.100] [0.057]

SMT LN: Single axial 7,3 4,80 3,23 Wet media


barbless port 4,0
[0.29] [0.189] [0.127]
8,0
[0.16] 2,95 Dry media [0.32]
4 5 6 [0.116] 0,25 Typ. 6 5 4
[0.010]

5,5
[0.22]
11,0
6,3 ø5,00 2,68 11,5 [0.43]
[0.25] [0.197] [0.106] [0.45]

6X 1,28
[0.050]

1,0
3 2 1 [0.04] 4,2 1 2 3
[0.17] 6X 0,46
[0.018]
2,54 Typ. 2X 1,45
[0.100] [0.057]

SMT JN: Single radial


8,0
barbless port 4,65 4,0
3,38 Wet media
[0.32] 2.16
[0.183] [0.16] 1,47 [0.085]
[0.133] 2,54 Typ.
[0.100] [0.058]
3,10 Dry media 6 5 4
4 5 6 [0.122]
0,7
[0.03]
4,45
[0.175]

11,0
6,3 11,5 [0.43]
[0.25] [0.45]
1,88
[0.074]

1,0
[0.04] 0,25 Typ.
3 2 1 4,2 [0.010] 6X 1,28 1 2 3
7,3 [0.17] [0.050] 6X 0,46
[0.29] [0.018]

Sensing and Internet of Things 11


BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES

FIGURE 6. SMT PACKAGE DIMENSIONAL DRAWINGS (CONTINUED)


SMT JJ: Dual radial
barbless ports, same
side
8,0
3,38 Wet media 2,82 [0.32]
2X 4.0 [0.133] [0.111] 2,54 Typ.
[0.16] [0.100]
2X 4.65 3,10 Dry media
[0.122] 2X 1,45 5,06 Wet media
[0.183] [0.057] 6 5 4
4 5 6 [0.199]
0,7
[0.03] 4,78 Dry media
[0.188]
4.45 2X 1,88
Port 1 [0.175] [0.074]

2,10 6,3 Port 2 11,0


[0.083] [0.25] 11,5
Port 1 [0.45] [0.43]

Port 2 4,45
[0.175]

1,0
3 2 1 [0.04] 4,2 0,25 Typ. 1 2 3
6X 1,28
7,3 [0.17] [0.010] [0.050]
[0.29] 6X 0,46
[0.018]

SMT RN: Single radial


barbed port

8,0
[0.32] 2,01
3,58 Wet media 2,54 Typ. [0.079]
4,0 [0.100] 4,75
[0.141] [0.187]
[0.16] 2X 1,45
4 5 6 3,30 Dry media [0.057] 6 5 4
0,5 [0.129]
[0.02]
ø1,60
[0.063] ø1,75
[0.069] 4,55
[0.179]

6,3 11,0
[0.25] 11,5
[0.45] [0.43]
ø2,10
[0.083]

1,0
3 2 1 [0.04] 0,25 Typ. 1.65
4,2 [0.010] 6X 1,28 1 2 3
[0.065]
7,3 [0.17] [0.050]
[0.29] 6X 0,46
[0.018]

SMT RR: Dual radial


barbed ports, both sides

8,0
3,58 Wet media 2,78 [0.32]
[0.141] [0.109] 2,54 Typ.
2X 4.75 2X 4.0 3,30 Dry media [0.100]
[0.187] [0.16] [0.129] 2X 1,45 4,76
4 5 6 [0.057] 6 5 4 [0.187]
3,10
[0.122] 0,5 2X ø1,60
[0.02] 4,55 [0.063]
1,90 Port 1
[0.075] [0.179]

11,5 2X ø2,10
6,3 11,0 [0.083]
[0.25] Port 1 [0.45]
[0.43]
Port 2
Port 2 4,55
2X ø1,75 [0.179]
[0.069]
1,0
3 2 1 [0.04] 4,2 0,25 Typ. 1 2 3
[0.010] 6X 1,28
7,3 [0.17] [0.050] 6X 0,46
[0.29] [0.018]

12 Sensing and Internet of Things


BASIC BOARD MOUNT PRESSURE SENSORS, ABP SERIES

FIGURE 7. LEADLESS SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].)
Leadless SMT NN: No port

4.0
[0.16] 3,23 Wet media
1 2 3 [0.13] 1,0 3 2 1
[0.04]
2,95 Dry media
3.5 [0.12]
[0.14]
6,3 3,00 7,0
[0.25] [0.118]
6X 1,25 [0.28]
[0.049]

6 5 4 4 5 6
7,3 2,5 Typ. 1,5
[0.29] [0.10] [0.06]
8,0
[0.32]

Leadless SMT AN: Single


axial barbed port 4.0 3,63 Wet media
[0.16] 1,0 [0.14]
7,0
1 2 3 [0.28] [0.04] 3 2 1
3,35 Dry media
3,56 [0.13]
3.5 [0.140]
[0.14]
6,3 ø2,74 3,00 7,0
[0.25] [0.108] [0.118] 6X 1,25 [0.28]
[0.049]
ø1,91 ø2,32
[0.075]
[0.091]
6 5 4 4 5 6
7,3 2,5 Typ. 1,5
[0.29] [0.10] [0.06]
8,0
[0.32]

Leadless SMT LN: Single


axial barbless port 4.0 3,23 Wet media
[0.16] [0.13]
1 2 3 1,0
[0.04] 3 2 1
2,95 Dry media
[0.12]
3.5
[0.14]
6,3 ø2,68 3,00 7,0
[0.25] [0.106] Port 1 [0.118] 6X 1,25 [0.28]
[0.049]
ø5,0
[0.20]
6 5 4 4,1 0,7 4 5 6
7,3 2,5 Typ. 1,5
[0.29] [0.16] [0.03]
[0.10] [0.06]
8,0
[0.32]

TABLE 8. PINOUTS
OUTPUT TYPE PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6
I2C GND Vsupply INT NC SDA SCL
SPI GND Vsupply SS NC MISO SCLK
analog GND NC Vout NC NC Vsupply

FIGURE 8. RECOMMENDED PCB LAYOUTS


DIP SMT Leadless SMT

Gage reference hole: do not plug Gage reference hole: do not plug
6X ø0.73 0,65 Gage reference hole: do not plug
1 2 3 [0.029] [0.026]
1,30
[0.051]
1 2 3
6,00 6,00
[0.236] 8,85 4,00
[0.236] [0.348] 7,00
[0.157] 1 2 3
11,00 3,25 [0.28]
11,25 11,0 0.128]
[0.443] [0.433] 8,00
[0.433] 6 5 4 [0.315]
3,00
5,00 12,35 [0.118]
5,00 [0.315]
[0.197] [0.197]
6 5 4

2,73 2,50
6 5 4 [0.098]
[0.107]
2,54 8,00
2,73 2,73 2,54 [0.315]
[0.107] [0.1] [0.107] [0.1]
8,00 8,00
[0.315] [0.315]

Sensing and Internet of Things 13


ADDITIONAL MATERIALS WARRANTY/REMEDY
m WARNING
The following associated literature is Honeywell warrants goods of its manu- PERSONAL INJURY
available at sensing.honeywell.com: facture as being free of defective materi-
DO NOT USE these products as safety
• Product range guide als and faulty workmanship during the or emergency stop devices or in any
• Installation instructions applicable warranty period. Honeywell’s other application where failure of the
standard product warranty applies un- product could result in personal injury.
• Application note
less agreed to otherwise by Honeywell in Failure to comply with these
writing; please refer to your order ac- instructions could result in death or
knowledgment or consult your local sales serious injury.
office for specific warranty details. If war-
ranted goods are returned to Honeywell
during the period of coverage, Honeywell
m WARNING
will repair or replace, at its option, without MISUSE OF
charge those items that Honeywell, DOCUMENTATION
in its sole discretion, finds defective. • The information presented in this
The foregoing is buyer’s sole remedy product sheet is for reference only.
Do not use this document as a
and is in lieu of all other warranties,
product installation guide.
expressed or implied, including those • Complete installation, operation,
of merchantability and fitness for a and maintenance information
particular purpose. In no event shall is provided in the instructions
Honeywell be liable for consequential, supplied with each product.
special, or indirect damages. Failure to comply with these
instructions could result in death or
While Honeywell may provide applica-
serious injury.
tion assistance personally, through our
literature and the Honeywell web site, it
is buyer’s sole responsibility to determine
the suitability of the product in the ap-
plication.

Specifications may change without


notice. The information we supply is
believed to be accurate and reliable as of
FOR MORE INFORMATION this writing. However, Honeywell assumes
Honeywell Sensing and Internet of no responsibility for its use.
Things services its customers through a
worldwide network of sales offices and
distributors. For application assistance,
current specifications, pricing or the
nearest Authorized Distributor,
visit sensing.honeywell.com or call:
USA/Canada +1 302 613 4491
Latin America +1 305 805 8188
Europe +44 1344 238258
Japan +81 (0) 3-6730-7152
Singapore +65 6355 2828
Greater China +86 4006396841

Honeywell
Sensing and Internet of Things
830 East Arapaho Road
Richardson, TX 75081
32305128-G-EN | G | 07/20
sensing.honeywell.com © 2020 Honeywell International Inc. All rights reserved.