Features and Benefits Application Examples: Relative Pressure Sensor IC
Features and Benefits Application Examples: Relative Pressure Sensor IC
Ordering Information
Product Code Temperature Package Option Code Packing
Code Code Form Code
MLX90821 L XG DBA-003 RE
MLX90821 L XG DBA-005 RE
MLX90821 L XG DBA-006 RE
MLX90821 V XG DBA-008 RE
MLX90821 L XG DBA-100 RE
Legend:
Temperature Code: L = -40°C to 150°C
V = -40°C to 115°C
Package Code: XG = SOIC16 WB cavity package
Option Code: DBA-003 = -0.06 to 0.26bar relative pressure / 0.5V to 4.5V analog output
DBA-005 = -0.05 to 0.05bar relative pressure / 0.5V to 4.5V analog output
DBA-006 = -0.2 to 0.5bar relative pressure / 4.5V to 0.5V analog output
DBA-008 = -0.0375 to 0.0125 bar relative pressure / 4.5 V to 0.5 V analog output
DBA-100 = -0.06 to 0.26bar relative pressure / 193 to 3896LSB SENT output / NTC
Packing Form: RE = Reel
Ordering example: MLX90821LXG-DBA-003-RE
Piezoresistive
sensing element
On chip temperature
sensor
Compensation
protocol.
Vbrg Pressure Linearization
InP
PGA
M
Vana
Programmable Filter
DAC
12 bits
Gain
Analog
Output
Using a best in class MEMS sensor enables reliably
OPA
U
X
ADC
16 bits
and accurately measuring very low pressures of a
SENT
InN InP, InN, VEXT
Rom
Output few tenths of millibars. An optimized architecture
EEPROM
NTC
Input
External NTC
interface
Ram
Test Test
and a high density CMOS technology imparts the
Oscillator Gnd
MLX90821 with best in class automotive EMC
performance. A DSP based architecture using a 16bit
Figure 1: Functional block diagram microcontroller provides outstanding performance
in terms of initial accuracy of both pressure and
optionally external NTC temperature.
A smart package and die assembly concept suits
applications with stringent automotive temperature
and stress conditions needing small drift over life.
Contents
Features and Benefits ....................................................................................................................... 1
Application Examples ........................................................................................................................ 1
Ordering Information ........................................................................................................................ 1
Functional Diagram ........................................................................................................................... 2
General Description .......................................................................................................................... 2
Glossary of Terms ............................................................................................................................. 5
Absolute Maximum Ratings .............................................................................................................. 5
Pin Definitions and Descriptions ........................................................................................................ 6
General Electrical Specifications........................................................................................................ 7
Detailed General Description .......................................................................................................... 8
Default programmed settings ....................................................................................................... 10
Default Characteristics DBA-003 ............................................................................................... 13
Default Characteristics DBA-005 ............................................................................................... 13
Default Characteristics DBA-006 ............................................................................................... 14
Default Characteristics DBA-008 ............................................................................................... 14
Default Characteristics DBA-100 ............................................................................................... 15
Filters ........................................................................................................................................... 16
PFLT ........................................................................................................................................... 16
SSF ............................................................................................................................................. 16
Analog Front End .......................................................................................................................... 17
ADC .............................................................................................................................................. 19
Digital ........................................................................................................................................... 19
NTC Temperature Linearization..................................................................................................... 20
SENT Configuration ....................................................................................................................... 22
Fast Channel Configuration ....................................................................................................... 22
Slow Channel Configuration ...................................................................................................... 22
Wrong Connections Overview Analog Output ............................................................................... 27
Wrong Connections Overview SENT Output .................................................................................. 28
Diagnostics ................................................................................................................................... 29
Input Diagnostics....................................................................................................................... 29
Diagnostic Sources .................................................................................................................... 29
Glossary of Terms
Bar: Pressure unit (1bar = 100kPa)
POR: Power-on Reset
ADC: Analog to Digital Converter
DAC: Digital to Analog Converter
DSP: Digital Signal Processor
EMC: Electro Magnetic Compatibility
Vbrg: Sensor bridge supply
InP: Positive sensing element input
InN: Negative sensing element input
OV: Over Voltage
UV: Under Voltage
SENT: Single Edge Nibble Transmission
FC: SENT Fast Channel
FC1: SENT Fast Channel 1
FC2: SENT Fast Channel 2
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-rated
conditions for extended periods may affect device reliability.
The sensor interface containing the readout circuit is integrated in the same package as the sensing element.
The electronics front end amplifies the signal from the bridge, performs a coarse offset compensation and
an ADC conversion. The DSP performs the compensations over temperature. Furthermore, the digital circuit
provides some filtering, the possibility to linearize the pressure signal and also implements the clamping
function. The analog back end consists of a 12 bit DAC and an output driver. This chip delivers an analog
output proportional to the pressure or a SENT output compliant with the rev 4 from April 2016 of the SAE
J2716 specification. An accurate factory calibrated external NTC temperature is also available on the SENT
output.
4 Number of SENT frames between pressure step and settled output (last frame containing stable pressure data)
A broken wire detection block allows actively driving the output to one of the rails in case of a broken supply
or ground connection. Extensive protection of the supply lines allows the MLX90821 to handle extreme
overvoltage conditions and is immune to severe external disturbances. Several diagnostic functions (over -
voltage, under-voltage, overpressure, under pressure detections) have been implemented on the 90821 and
can be enabled by programming EEPROM settings. Figure 3 describes MLX90821 block diagram.
Rom SENT
InN InP, InN, VEXT Output
EEPROM
NTC External NTC Test Test
interface
Input Ram
Oscillator Gnd
The analog output transfer curves as described below are valid assuming a supply voltage of 5V for the IC, the
analog output scales in a ratiometric way to the supply voltage.
Output
HCL
O2
εp
εo
O1 Relative Pressure
LCL in Bar
P1 P2
Temperature Factor
Pressure Accuracy
Fe
Fc
Temperature Factor
Pressure Accuracy
Fe
Fc
SENT Output
in LSB
4088
1 Temperature in °C
-73.025 437.85
Temperature Accuracy
(°C)
εTe
εTc
εTe
Transfer Curve
Symbol Remarks Value Unit
Parameter
Pressure 1 P1 See Figure 4: Pressure -0.06 Bar
transfer function
Pressure 2 P2 0.26 Bar
description at room
Output 1 O1 temperature 0.5 V
Output 2 O2 4.5 V
Low clamping level LCL 0.25 V
High clamping level HCL 4.75 V
Pressure Accuracy
Symbol Remarks Min Typ Max Unit
Parameter
Overall accuracy
expressed as output -60 60 mV
Output accuracy εo value (FS range from -1.5 1.5 %FS
0.5V to 4.5V)
Overall accuracy
Pressure accuracy εp expressed as pressure -4.8 4.8 mBar
value
Center temperature See Figure 5: Pressure
Fc accuracy temperature 1
accuracy factor
factor
Extended temperature
Fe 1.5
accuracy factor
Table 5: DBA-003 Default configuration
Transfer Curve
Symbol Remarks Value Unit
Parameter
Pressure 1 P1 See Figure 4: Pressure -0.05 Bar
transfer function
Pressure 2 P2 0.05 Bar
description at room
Output 1 O1 temperature 0.5 V
Output 2 O2 4.5 V
Low clamping level LCL 0.5 V
High clamping level HCL 4.5 V
Pressure Accuracy
Symbol Remarks Min Typ Max Unit
Parameter
Overall accuracy
expressed as output -100 100 mV
Output accuracy εo value (FS range from -2.5 2.5 %FS
0.5V to 4.5V)
Overall accuracy
Pressure accuracy εp expressed as pressure -2.5 2.5 mBar
value
Center temperature See Figure 5: Pressure
Fc accuracy temperature 1
accuracy factor
factor
Extended temperature
Fe 1.5
accuracy factor
Table 6: DBA-005 Default configuration
Transfer Curve
Symbol Remarks Value Unit
Parameter
Pressure 1 P1 See Figure 4: Pressure -0.2 Bar
transfer function
Pressure 2 P2 0.5 Bar
description at room
Output 1 O1 temperature 4.5 V
Output 2 O2 0.5 V
Low clamping level LCL 0.3 V
High clamping level HCL 4.7 V
Pressure Accuracy
Symbol Remarks Min Typ Max Unit
Parameter
Overall accuracy
expressed as output -40 40 mV
Output accuracy εo value (FS range from -1 1 %FS
0.5V to 4.5V)
Overall accuracy
Pressure accuracy εp expressed as pressure -7 7 mBar
value
Center temperature See Figure 5: Pressure
Fc accuracy temperature 1
accuracy factor
factor
Extended temperature
Fe 1.5
accuracy factor
Table 7: DBA-006 Default configuration
Transfer Curve
Symbol Remarks Value Unit
Parameter
Pressure 1 P1 See Figure 4: Pressure -0.0375 Bar
transfer function
Pressure 2 P2 0.0125 Bar
description at room
Output 1 O1 temperature 4.5 V
Output 2 O2 0.5 V
Low clamping level LCL 0.3 V
High clamping level HCL 4.7 V
Pressure Accuracy
Symbol Remarks Min Typ Max Unit
Parameter
Overall accuracy
expressed as output -160 160 mV
Output accuracy εo value (FS range from -4 4 %FS
0.5V to 4.5V)
Overall accuracy
Pressure accuracy εp expressed as pressure -2 2 mBar
value
Center temperature See Figure 6: Pressure
Fc accuracy temperature 1
accuracy factor
factor (temperature
Extended temperature code V)
Fe 1.5
accuracy factor
Table 8: DBA-008 Default configuration
Transfer Curve
Symbol Remarks Value Unit
Parameter
Pressure 1 P1 See Figure 4: Pressure -0.06 Bar
transfer function
Pressure 2 P2 0.26 Bar
description at room
Output 1 O1 temperature 193 LSB
Output 2 O2 3896 LSB
Low clamping level LCL 1 LSB
High clamping level HCL 4088 LSB
Pressure Accuracy
Symbol Remarks Min Typ Max Unit
Parameter
Overall accuracy
expressed as output -55 55 LSB
Output accuracy εo value (FS range from -1.5 1.5 %FS
193 to 3896)
Overall accuracy
Pressure accuracy εp expressed as pressure -4.8 4.8 mBar
value
Center temperature See Figure 5: Pressure
Fc accuracy temperature 1
accuracy factor
factor
Extended temperature
Fe 1.5
accuracy factor
NTC Accuracy
Symbol Remarks Min Typ Max Unit
Parameter
Overall accuracy
using the default NTC
Center NTC as described in Table
εTc 13
-1 1 °C
temperature accuracy
See Figure 8: NTC
temperature accuracy
Extended NTC
εTe -2 2 °C
temperature accuracy
Table 9: DBA-100 Default configuration
Filters
There are two filters available to filter the pressure signal. The first filter is a Small Signal Filter which can be
disabled or enabled. The second filter is a first order low pass filter for the pressure signal which has a
programmable depth.
PFLT
PFLT is a programmable first order low pass filter. The depth of this filter can be selected. This filter can be
configured to select the optimal trade-off between response time and output noise.
The PFLT parameter in the formula is set in EEPROM and can have a value between 0 and 9. An overview of
typical response times when applying a step on the input using different PFLT filter settings can be found in Table
10. Filter setting 0 disables the PFLT.
SSF
The SSF (Small Signal Filter) is a digital filter which is designed not to have an impact on the response time of a
fast changing pressure signal like a pressure step. When a large signal change at the input is present, the filter is
bypassed and not filtering the signal. For small signal changes, which are in most cases noise, the filter is used
and filtering the pressure signal.
The Small Signal Filter can be enabled or disabled in EEPROM. It is advised not to use the SSF in combination with
the PFLT enabled.
5 Time needed for the output to change from an input pressure step to 90% of its final value.
6 Tick time is set to 3us and Pause Pulse is enabled.
G = 1.25 or 3.5
G = 4.5 to 10.5 CSOF: 1/3 to 2/3
3 bits of VDDA G = 1.6, 3.2 or 6.4
InP
Input
Diag OPA OPA
nostics
The first stage is an instrumentation amplifier of which the gain can be programmed using 3 bits to cover a gain
range between 4.5 and 10.6.
Transfer equation:
OUTP1 – OUTN1 = Gst1*(InP – InN) in phase 1
OUTP1 – OUTN1 = Gst1*(InN – InP) in phase 2
The second stage is a fully differential amplifier. The gain of the amplifier can be calibrated using 1 bit.
Transfer equation:
OUTP2 – OUTN2 = -Gst2*(OUTP1 – OUTN1) – Gst2*(CSOF1 – CSOF2) in phase 1
OUTP2 – OUTN2 = -Gst2*(OUTN1 – OUTP1) – Gst2*(CSOF2 – CSOF1) in phase 2
The CSOF1 and CSOF2 signals are generated by the coarse offset DAC with the following transfer functions:
2 1 VDDA CO[6 : 0]
+ (− 1) * − *
VDDA
CSOF1 =
CO 7
*
2 3 3 2 127
CO 7 2 1 VDDA CO[6 : 0]
− (− 1) * − *
VDDA
CSOF 2 = *
2 3 3 2 127
CO[6:0] fixes the DAC output. CO7 is used for the polarity.
The third stage is an integrator which is controlled using 2 bits to set a gain between 1.6 and 6.4
Transfer equation at the outputs of the amplifier:
OUTP3 – OUTN3 = -N*(C1/C2)*(OUTP2 – OUTN2)
OUTP3_common_mode and OUTN3_common_mode = VCM = VDDA/2
In this equation N represents the number of integration cycles which is a fixed value of N = 40.
C2 is a fixed feedback capacitor of approximately 5pF. C1 can have 3 different values: 0.2pF, 0.4pF or 0.8pF.
An overview of all possible values for Gst1, Gst2 and Gst3 can be found in Table 11 below.
The input stage is designed to work with an input common-mode voltage range between 42%Vbrg and 58%Vbrg.
ADC
The 16 bit differential ADC has a range from –VDDA/2 to +VDDA/2.
There are 7 different ADC channels. Channel 0 is not used. Table 12 below describes all the channels.
The different channels are converted in a constantly repeating sequence. A new ADC conversion is done every
50us following the sequence shown below in Figure 10. This is resulting in an updated pressure output value
every 200us.
P Tint P Text P Tntc P Vsup P Tint P Text P Tntc P InP/InN P Tint P ...
Digital
The digital is built around a 16-bit microcontroller. It contains besides the processor also ROM, RAM and EEPROM
and a set of user and system IO registers.
Temperature compensation of the pressure signal and pressure linearization is handled by the microcontroller.
For the pressure compensation there are EEPROM parameters allocated to be able to cover a large variety of
calibration approaches.
Both for gain and offset of the pressure signal, there is a separate temperature dependency programmable
ranging from a temperature independence to a first order, second order and finally a third order compensation.
This is reflected in EEPROM parameters for the offset (O0, O1, O2 and O3) and for the gain (G0, G1, G2 and G3).
If required, the linearity of the pressure signal can also be compensated without a temperature dependency or
with a first order temperature dependency through EEPROM parameters L0 and L1.
Linearization of the NTC temperature is also covered partially by the microcontroller. More information in this
topic can be found in chapter 16.
VDDA
3 or 4 points
MLX calibration
@ 3 temp
Rs
Vdiv LUT
ADC_raw[15:0] ADC_comp[15:0]
Calibration
VDDA/2 ADC &
Compensation
ADC_ROM
=>
Rntc Tntc
The default NTC characteristic which is calibrated on option code DBA-100 can be found in Table 13. When using
an NTC which does not match the coefficients described above, it is advised to contact Melexis.
The EEPROM coefficients which are used for the conversion from ADC_raw to ADC_comp are N0 to N3,
N0_Diff_Low to N3_Diff_Low, N0_Diff_High to N3_Diff_High and TEMP1 to TEMP3.
SENT Configuration
The SENT output is designed to be compliant with the SAE J2716 rev. Apr 2016 SENT standard. The tick time is
configurable in EEPROM using parameter TICK_DIV. The available tick time settings are 3us, 4us, 6us, 10us, 12us
and 16us. A pause pulse can also be enabled to have a fixed frame length of 282 ticks. This can be done using
parameter PAUSE. The default configuration for option code DBA-100 is 3us tick time and pause pulse enabled.
FC_CFG
# Fast Channel 1 Fast Channel 2 Remark
setting
1 0 Pressure (3x 4 bit) Inverse of Pressure (3x 4 bit)
2 1 Pressure (3x 4 bit) Rolling counter (2x 4 bit) and
inverse of MSN of Pressure
(1x 4 bit)
3 2 Pressure (3x 4 bit) Medium temperature Media temperature can either be
(3x 4 bit) NTC or sensing element temperature.
(Tmedium_Select).
Default for option code DBA-100.
4 3 Pressure (3x 4 bit) Internal temperature Internal temperature can either be
(3x 4 bit) PTAT or sensing element
temperature (Tinternal_Select).
5 4 Pressure only (3x 4 bit) /
6 5 Pressure only (4x 3 bit) /
7 6 Data indicated by pointer 1 Data indicated by pointer 2 In this mode no diagnostics are
(3x 4 bit) (3x 4 bit) available. FC configuration only used
by Melexis.
8 7 Pressure (3x 4 bit) 0 (3x 4 bit)
The selection of the fast channel output mode can be done by changing the parameter ‘FC_CFG’ in the EEPROM.
In case Medium temperature is selected to be available on fast channel 2, the type of media can be defined in
EEPROM using parameter ‘Tmedium_Select’. When selecting 0, linearized NTC temperature will be available.
Selecting 1 enables sensing element temperature. Sensing element temperature is not calibrated by default.
For Internal temperature, also two options are available defined in EEPROM parameter ‘Tinternal_Select’ where
0 corresponds to on chip factory calibrated PTAT temperature and 1 corresponds to sensing element
temperature. The same comment regarding the calibration of the sensing element temperature calibration as
made above applies here.
An overview of the different slow channel messages which are available in the MLX90821 can be found in Table
15. From this table 16 messages can be configured completely in EEPROM. The 12 bit data content of these
messages can be configured freely. The ID of programmable message PR0, PR1, PR2 and PR3 is copied from
EEPROM (2x 4 bit). The ID of PR5 is 1 bit higher than of PR4. The same is valid for the other pairs: PR6-7, PR8-9, …,
PR14-15. This programmable ID is indicated in Table 15 as 0xYZ.
All programmable messages can also be enabled and disabled, but not all independently of each other:
• PR0, PR1, PR2 and PR3 can be each independently enabled or disabled
• PR4 and PR5 are together enabled or disabled
• PR6 and PR7 are together enabled or disabled
• PR8, PR9, PR10 and PR11 are together enabled or disabled
• PR12, PR13, PR14 and PR15 are together enabled or disabled
Messages which have a “Y” in the column Rep of Table 15 can be selected to have a higher occurrence in the slow
channel message sequence. Their repetition rate can be configured as indicated in Table 16.
The repeatable messages MID01h, MID10h and MID23h can be configured individually to have their own
repetition rate. The repetition factor setting can be done in respectively “SENT_REP_FACT_ID_01”,
“SENT_REP_FACT_ID_10” and “SENT_REP_FACT_ID_23”.
Once a message is configured to be repeatable, it will automatically have the highest priority. Therefore it will
appear first in the slow message sequences.
The priority order between MID01, MID10 and MID23 can also be configured using EEPROM parameter
“SC_R_O”:
• SC_R_O = 0: Priority order: ID01h > ID10h > ID23h
• SC_R_O = 1: Priority order: ID10h > ID23h > ID01h
0V 5V 0V 0V – No Normal operation
communication
0V 5V 5V 5V – No Normal operation
communication
0V 5V 18V 18V – No Normal operation
communication
0V 0V SAE Standard No communication Normal operation
Load Circuit
0V 18V SAE Standard No communication Normal operation
Load Circuit
5V 5V SAE Standard No communication Normal operation
Load Circuit
5V 0V SAE Standard No communication Normal operation
Load Circuit
Table 18: Wrong connections overview
Diagnostics
Input Diagnostics
An overview of the different input diagnostics conditions and their corresponding fault band and diagnostic
source can be found in Table 19.
Diagnostic Sources
The MLX90821 product has several internal checks which monitor the status of device. These checks or
diagnostic sources can be enabled or disabled based on the sensor module requirements. An overview of the
different diagnostic sources, their enable/disable parameter and the explanation of their functionality can be
found below in Table 20. The default diagnostic configuration for the different option codes can be found in Table
21.
The level of the over and under voltage diagnostics can be configured according to the ranges described in Table
22.
Parameter Min Max Units Comment
Optional and Programmable
Under voltage detection
3.25 5.74 V with 8 bits in parameter
threshold range VSUP_LOW
Optional and
Overvoltage detection 4.25 6.74 V Programmable with 8 bits in
threshold range parameter VSUP_HIGH
Over-/Under-voltage
200 mV
detection accuracy
Table 22: MLX90821 under and overvoltage detection
Fast Fast
Parameter Parameter
Channel Channel
ERR_VSUP V_ERR FCE_VSUP ERR_TCH FCE_TCHIP
No change 0 Not applicable 4091 0
4091 1 0 4090 1
4090 1 1
Table 23: Fast channel error configuration
The diagnostic slow channel message (MID 1) can be enabled or disabled independent of the other slow channel
messages and it has an adjustable repetition factor (2, 4, .., 30).
More information on the different diagnostics shown in SENT, their fast channel, slow channel and status bit
mapping can be found in the tables below.
Multiple diagnostic errors can be flagged in the range 8xxh – FFFh in case parameter DIAG_INT is set to 0.
DIAG_INT initialization error 4090 4090 1 1 4090 nc 1 nc 4090 4090 1 1 4090 4090 1 1
DIAG_P1 P @ FC1 = 1 nc 1 nc 1 nc 1 nc 1 nc 1 nc 1 nc 1 nc
DIAG_T1 T @ FC2 = nc 1 nc 1 nc 1 nc 1
ERR_EN_TINT T_INT nc nc nc nc nc nc nc nc nc nc nc nc
ERR_EN_TMED T_MED nc nc nc nc nc nc nc nc nc nc nc nc
DIAG_P1 P @ FC1 = 1 1 1 1 nc nc 1 nc 1 nc 1 nc
DIAG_T1 T @ FC2 = nc nc nc nc
DIAG_T1 T @ FC2 = nc nc nc nc
DIAG_T2 T @ FC2 = nc nc nc nc
DIAG_T2 T @ FC2 = nc nc nc nc
ERROR_ENABLE
ERROR Slow channel diagnostic
parameter
DIAG_T2 T @ FC2 = 805h (Remark: value 186 matches with -50 degC)
DIAG_T2 T @ FC2 = 804h (Remark: value 2266 matches with +210 degC)
SENT Timings
tsu2
tsu1 tframe
VDD
Application Information
1 16
2 15
3 14
4 13
GND 5 12
100nF 6 11 100nF
7 10
OUT 8 9 VDD
1 16
2 15
3 14
4 13
2.2nF
GND 5 12
6 11 OUT
NTC optional 10nF NTC
If not used 7 10
connect pin 6
to GND 8 9 VDD
100nF
These recommendations for external components are only providing a basic protection. Depending on the
module design and the EMC speciation requirements different configurations can be needed.
▪ IPC/JEDEC J-STD-020
Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices
(classification reflow profiles according to table 5-2)
▪ EIA/JEDEC JESD22-A113
Preconditioning of Nonhermetic Surface Mount Devices Prior to Reliability Testing
(reflow profiles according to table 2)
Wave Soldering SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)
▪ EN60749-20
Resistance of plastic- encapsulated SMD’s to combined effect of moisture and soldering heat
▪ EIA/JEDEC JESD22-B106 and EN60749-15
Resistance to soldering temperature for through-hole mounted devices
▪ EN60749-15
Resistance to soldering temperature for through-hole mounted devices
Solderability SMD’s (Surface Mount Devices) and THD’s (Through Hole Devices)
For all soldering technologies deviating from above mentioned standard conditions (regarding peak temperature,
temperature gradient, temperature profile etc) additional classification and qualification tests have to be agreed
upon with Melexis.
The application of Wave Soldering for SMD’s is allowed only after consulting Melexis regarding assurance of
adhesive strength between device and board.
Melexis is contributing to global environmental conservation by promoting lead free solutions. For more
information on qualifications of RoHS compliant products (RoHS = European directive on the Restriction Of the
use of certain Hazardous Substances) please visit the quality page on our website:
http://www.melexis.com/quality.aspx
ESD Precautions
Electronic semiconductor products are sensitive to Electro Static Discharge (ESD).
Always observe Electro Static Discharge control procedures whenever handling semiconductor products.
Package Information
Contact
For the latest version of this document, go to our website at www.melexis.com.
For additional information, please contact our Direct Sales team and get help for your specific needs:
Email : [email protected]
Email : [email protected]
Disclaimer
The information furnished by Melexis herein (“Information”) is believed to be correct and accurate. Melexis disclaims (i) any and all liability in connection with or arising out of the
furnishing, performance or use of the technical data or use of the product(s) as described herein (“Product”) (ii) any and all liability, including without limitation, special,
consequential or incidental damages, and (iii) any and all warranties, express, statutory, implied, or by description, including warranties of fitness for particular purpose, non-
infringement and merchantability. No obligation or liability shall arise or flow out of Melexis’ rendering of technical or other services.
The Information is provided "as is” and Melexis reserves the right to change the Information at any time and without notice. Therefore, before placing orders and/or prior to
designing the Product into a system, users or any third party should obtain the latest version of the relevant information to verify that the information being relied upon is current.
Users or any third party must further determine the suitability of the Product for its application, including the level of reliability required and determine whether it is fit for a
particular purpose.
The Information is proprietary and/or confidential information of Melexis and the use thereof or anything described by the In formation does not grant, explicitly or implicitly, to
any party any patent rights, licenses, or any other intellectual property rights.
This document as well as the Product(s) may be subject to export control regulations. Please be aware that export might require a prior authorization from competent authorities.
The Product(s) are intended for use in normal commercial applications. Unless otherwise agreed upon in writing, the Product(s) are not designed, authorized or warranted to be
suitable in applications requiring extended temperature range and/or unusual environmental requirements. High reliability app lications, such as medical life-support or life-
sustaining equipment are specifically not recommended by Melexis.
The Product(s) may not be used for the following applications subject to export control regulations: the development, product ion, processing, operation, maintenance, storage,
recognition or proliferation of 1) chemical, biological or nuclear weapons, or for the development, production, maintenance o r storage of missiles for such weapons: 2) civil
firearms, including spare parts or ammunition for such arms; 3) defense related products, or other material for military use or for law enforcement; 4) any applications that, alone
or in combination with other goods, substances or organisms could cause serious harm to persons or goods and that can be used as a means of violence in an armed conflict or any
similar violent situation.
The Products sold by Melexis are subject to the terms and conditions as specified in the Terms of Sale, which can be found at https://www.melexis.com/en/legal/terms-and-
conditions.
This document supersedes and replaces all prior information regarding the Product(s) and/or previous versions of this document.
Melexis NV © - No part of this document may be reproduced without the prior written consent of Melexis. (2016)